China KEMA Quality Ltd. Guangzhou Branch 7/F., Block C, Wushan Technology Plaza. Wushan Road, Tianhe District, Guangzhou 510630, P. R. China Tel +86 20 8331 8535 Fax +86 20 8331 8575 www.kemaquality.com KQGZ-F-PC4-005 Version: 2.0 4302294.50 EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of issue: 2010-09-06 Author Tim Yan By order of KOE Lighting Ltd. at Guangzhou City China Author : Tim Yan Reviewed : Arthur Liu Pages : 31 pages Annex : NIL

Upload: others

Post on 13-Apr-2021

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

China KEMA Quality Ltd. Guangzhou Branch 7/F., Block C, Wushan Technology Plaza. Wushan Road, Tianhe District, Guangzhou 510630, P. R. China Tel +86 20 8331 8535 Fax +86 20 8331 8575 www.kemaquality.com KQGZ-F-PC4-005 Version: 2.0

4302294.50 EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700

Guangzhou, date of issue: 2010-09-06 Author Tim Yan By order of KOE Lighting Ltd. at Guangzhou City China

Author : Tim Yan Reviewed : Arthur Liu

Pages : 31 pages Annex : NIL

Page 2: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 2 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

CONTENTS page

1 Conclusion .....................................................................................................3

1.1 Model description...........................................................................................3

1.2 Environment...................................................................................................6

2 Summary .......................................................................................................7

2.1 Applied standards ..........................................................................................7

2.2 Overview of results ........................................................................................7

2.3 Overview of measurement uncertainty ...........................................................8

3 General Information .......................................................................................9

3.1 Product Information........................................................................................9

3.2 Client Information...........................................................................................9

3.3 Test data......................................................................................................10

3.4 Environmental conditions .............................................................................10

4 Emission test results ....................................................................................11

4.1 Mains conducted disturbance voltage ..........................................................11

4.2 Radiated EM Field emission.........................................................................13

4.3 Radiated Magnetic Field emission................................................................18

4.4 Harmonic currents........................................................................................19

4.5 Voltage fluctuations (Flicker) ........................................................................20

5 Immunity Test Results..................................................................................21

5.1 Electrostatic discharge immunity..................................................................21

5.2 Radiated EM field immunity..........................................................................22

5.3 Electrical Fast Transient immunity................................................................23

5.4 Surge transient immunity .............................................................................24

5.5 RF Conducted immunity...............................................................................27

5.6 Power supply interruptions and dips.............................................................28

6 Identification of the equipment under test.....................................................29

7 Operating manual of Electronic transformer .................................................31

Page 3: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 3 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

1 CONCLUSION The equipment under test (EUT) meets the essential requirements of the EMC Directive 2004/108/EC. This report is base on report G080144A.900. In this update, the applied standards were upgraded. After reviewing, the radiated emission test was selected to repeat on models KLP350, KLP350x3 and KLP700 and the radiated magnetic emission test was selected to repeat on model KLP350x3 which with maximum power for verification. The test results in this report belong to models KLP350, KLP350x3 and KLP700. The conclusion and results stated in this test report are based on a non-recurrent examination of sample(s) provided by the applicant.

1.1 Model description The apparatus as supplied for the test are three LED power supplies, models KLP350, KLP350x3 and KLP700 for residential use and the products contain electronic control circuitry, but no earth connection. Based on manufacturer’s declaration, the luminaries is LED power supply with LED. On testing, models KLP350 and KLP700 were equipped with a 1 W LED; model KLP350x3 was equipped with a 3 W (3x1 W) LED. (1) Models KLP350, KLP350x3 and KLP700 have the same size, circuit diagram and

PCB layout, but the difference on output. Hence, model KLP350x3 was chosen for full testing; model KLP350 was chosen to repeat conducted emission test; model KLP700 was chosen to repeat conducted emission test and all immunity tests and the corresponding data is representative for all models listed in the report as well.

Page 4: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 4 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Figure 1 model KLP350

Figure 2 model KLP350x3

Page 5: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 5 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Figure 3 model KLP700 The operating modes as stated in the user manual are on mode and off mode.

Page 6: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 6 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

1.2 Environment The requirements and standards apply to equipment intended for use in:

� Residential (domestic) environment � Commercial and light-industrial environment Industrial environment Medical environment

Page 7: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 7 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

2 SUMMARY This chapter presents an overview of standards and results. Refer to the next chapters for details of measured test results and applied test levels.

2.1 Applied standards

Standard Year Title

EN 55015 2006

A1 2007

A2 2009

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment.

EN 61547 1995

A1 2000

Equipment for general lighting purposes – EMC immunity requirements

EN 61000-3-2 2006 Limits for harmonic currents emissions

EN 61000-3-3 2008 Limitation of voltage fluctuations and flicker

2.2 Overview of results

Emission tests Result

Mains conducted disturbance voltage (9 kHz – 30MHz) PASS Radiated Magnetic Field emission (9 kHz – 30MHz) PASS

Radiated disturbance field strength (30MHz– 300MHz) PASS Harmonic current emission PASS Limitation of voltage fluctuations (flicker) PASS

Immunity tests Result

Electrostatic Discharges (ESD) PASS Radiated EM Field PASS

Electrical fast transient (EFT) / Burst transients PASS

Surge transients PASS Conducted RF disturbances PASS Power supply voltage interruptions & dips PASS

Page 8: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 8 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

2.3 Overview of measurement uncertainty

Measurement Uncertainty

Mains disturbance voltage (9 kHz – 30MHz) ± 2,8 dB Radiated Magnetic Field emission (9 kHz – 30MHz) ± 2,7 dB

Radiated disturbance (30MHz– 300MHz) ± 4,9 dB

Page 9: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 9 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

3 GENERAL INFORMATION

3.1 Product Information

Equipment under test LED Power Supply

Trade mark Tested Type KLP350, KLP350x3 and KLP700

U nominal

P rated

KLP350: Pri: 100-240 V~; 50/60 Hz, 0,04 A, Sec: Constant Current DC350 mA; 0,5 -4 V Constant Voltage DC5,5 V; I ≤ 300 mA

KLP350x3: Pri: 220-240 V~; 50/60 Hz, 0,04 A, Sec: Constant Current DC350mA 0,5-10 V

Constant Voltage DC11,5 V; I ≤300 mA KLP700: Pri: 220-240 V~; 50/60 Hz, 0,04 A,

Sec: Constant Current DC700 mA 0,5-4 V Constant Voltage DC5,5 V; I ≤650 mA

3.2 Client Information

Applicant KOE Lighting Ltd. Contact person Kevin Chen

Telephone +86 20 8149 5509 / 8149 5529 / 8149 5550

Telefax +86 20 8149 5660

Address 25 Hejing Road, Dongsha, Liwan District,

Place Guangzhou City, Guangdong

Country China

Manufacturer/Factory KOE Lighting Ltd.

Contact person Kevin Chen

Telephone +86 20 8149 5509 / 8149 5529 / 8149 5550

Telefax +86 20 8149 5660

Address 25 Hejing Road, Dongsha, Liwan District,

Place Guangzhou City, Guangdong

Country China

Page 10: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 10 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

3.3 Test data

Location CEST & CGEL

Address

No 6, Haichengdong Street, Xingangdong Road, Haizhu District, Guangzhou, 510330, P. R. China & No.45, Shayongnan Street, Sanyuanli, Guangzhou, Guangdong, China

Date April 2008 & August 2010

Supervised by Coffee Li & Tim Yan

3.4 Environmental conditions Tests have been performed in a controlled laboratory environment, where the environmental conditions are maintained within the applicable ranges.

Ambient temperature 15 °C – 35 °C

Relative Humidity air 30% - 60%

Page 11: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 11 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

4 EMISSION TEST RESULTS

4.1 Mains conducted disturbance voltage

Standard EN 55015 Frequency [MHz] QP [dB(µV)] AV [dB(µV)]

0,009 – 0,05 110 N/A 0,05 – 0,15 90 – 80 *) N/A

0,15 – 0,50 66 – 56 *) 56 - 46 *)

0,50 – 5,0 56 46

5,0 – 30 60 50

*) Limits decreasing linearly with the logarithm of the frequency

Port AC mains input power

Test method LISN

Mode On mode with max power wastage

Results for model KLP350x3

QP [dB(µV)] AV [dB(µV)] Frequency [MHz]

Level Limit Level Limit

0,170 52,2 65,1 42,0 55,0 0,610 45,2 56,0 36,9 46,0 1,185 48,6 56,0 32,4 46,0 1,570 41,6 56,0 -- -- 1,675 -- -- 34,4 46,0 2,935 38,5 56,0 -- --

"QP" and "AV" are levels and limits referring to measurements with the quasi-peak and average detector. If the measured level "QP" does not exceed the limit for "AV", then no average measurement is necessary. No other significant emissions were measured at the frequency range of interest employing both the QP and AV detectors.

Page 12: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 12 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Results for model KLP350

QP [dB(µV)] AV [dB(µV)] Frequency [MHz]

Level Limit Level Limit

0,555 36,6 56,0 -- -- 1,265 43,9 56,0 -- -- 1,435 38,6 56,0 30,1 46,0 1,660 -- -- 31,3 46,0

"QP" and "AV" are levels and limits referring to measurements with the quasi-peak and average detector. If the measured level "QP" does not exceed the limit for "AV", then no average measurement is necessary. No other significant emissions were measured at the frequency range of interest employing both the QP and AV detectors. Results for model KLP700

QP [dB(µV)] AV [dB(µV)] Frequency [MHz]

Level Limit Level Limit

0,160 54,1 65,5 41,5 55,6 0,535 41,9 56,0 36,1 46,0

1,280 48,1 56,0 33,7 46,0 1,515 43,6 56,0 37,1 46,0 2,520 38,9 56,0 32,2 46,0

"QP" and "AV" are levels and limits referring to measurements with the quasi-peak and average detector. If the measured level "QP" does not exceed the limit for "AV", then no average measurement is necessary. No other significant emissions were measured at the frequency range of interest employing both the QP and AV detectors. Refer to chapter 6 for the test set-up. Conclusion:

PASS

Page 13: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 13 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

4.2 Radiated EM Field emission

Standard EN 55015

Port Enclosure with cabling

Test method Semi-Anechoic chamber

Mode On mode

Frequency [MHz] QP [dB(µV/m)] @10m *

30 – 230 30 230 – 300 37

* At the transition frequency, the lower limit applies.

Results for model KLP350x3

Horizontal

Page 14: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 14 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Vertical

QP [dB(µV/m)] @ 3m Frequency [MHz] Polarization

Level Limit Margin

43,0 V 31,0 40,0 9,0

137,0 V 31,7 40,0 8,3

138,0 H 32,3 40,0 7,7

139,8 H 32,4 40,0 7,6

No other significant emissions were measured at the frequency range of interest employing the QP detectors.

Page 15: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 15 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Results for model KLP350

Horizontal

Vertical

Page 16: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 16 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

QP [dB(µV/m)] @ 3m Frequency [MHz] Polarization

Level Limit Margin

32,2 V 33,6 40,0 6,4

90,3 V 32,8 40,0 7,2

150,0 H 37,9 40,0 2,1 200,0 H 24,7 40,0 15,3

No significant emissions were measured at the frequency range of interest employing the QP detectors. Results for model KLP700

Horizontal

Page 17: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 17 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Vertical

QP [dB(µV/m)] @ 3m Frequency [MHz] Polarization

Level Limit Margin

149,6 V 29,1 40,0 10,9

200,0 V 23,5 40,0 16,5

153,0 H 36,1 40,0 3,9

200,2 H 27,6 40,0 12,4

No significant emissions were measured at the frequency range of interest employing the QP detectors. Refer to chapter 6 for the test set-up. Conclusion:

PASS

Page 18: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 18 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

4.3 Radiated Magnetic Field emission

Standard EN 55015

Port Enclosure with cabling

Set-up Van Veen loop with 2 meter diameter

Mode On mode

Frequency [MHz] QP [dB(µA)]

0,009 – 0,07 88 0,07 – 0,15 88 – 58 *)

0,15 – 3,0 58 – 22 *)

3,0 – 30,0 22

*) Limits decreasing linearly with the logarithm of the frequency Results for model KLP350x3

Direction X- Axis

QP [dB(µA)] Frequency [MHz]

Level Limit

0,009 – 30,0 More than 20 dB below the limits

Direction Y- Axis

QP [dB(µA)] Frequency [MHz]

Level Limit

0,009 – 30,0 More than 20 dB below the limits

Direction Z- Axis

QP [dB(µA)] Frequency [MHz]

Level Limit

0,009 – 30,0 More than 20 dB below the limits

No significant emissions were measured at the frequency range of interest employing the QP detectors. Conclusion:

PASS

Page 19: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 19 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

4.4 Harmonic currents

Standard EN 61000-3-2

Port AC Mains supply

Rated power <25 W

Mode On mode with max. power wastage (model KLP350x3)

Class A All apparatus not classified as Class B, C or D Class B Portable tools

� Class C Lighting equipment Class D Personal computers, television receivers

Results and limits According to EN 61000-3-2 :2006, equipment with rated power less than or equal to 25W other than discharge lighting equipment, the requirement and limited for this case is not yet considered. Hence, the product is deemed to comply with the standard without any measurements Conclusion:

PASS

Page 20: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 20 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

4.5 Voltage fluctuations (Flicker)

Standard EN 61000-3-3

Port AC Mains supply

Voltage 230 VAC

Mode On mode with max. power wastage (model KLP350x3)

Equipment intended to be connected to 230/400 V, 50 Hz supply systems may not produce voltage fluctuations in the supply systems due to variation of the input current above the limits as stated below.

PST ≤ 1

PLT ≤ 0,65

dt > 3,3% ≤ 500 ms

dC ≤ 3,3%

dMAX ≤ 4%

Results Because of the low power rating (less than 25 W), the EUT is unlikely to produce significant voltage fluctuations or flicker, the flicker testing is not necessary. Conclusion:

PASS

Page 21: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 21 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

5 IMMUNITY TEST RESULTS

5.1 Electrostatic discharge immunity Electrostatic discharges (ESD) are the result of persons or objects that accumulate static electricity due to for instance walking on synthetic carpets. The ESD can influence the operation of equipment or damage its electronics, either by a direct discharge or indirectly by coupling or radiation. Both effects are simulated during the tests. Requirements

Standard EN 61547

Basic standard EN 61000-4-2

Port Enclosure

Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed.

Air discharges 8 kV

Contact discharges 4 kV

Mode On mode with max. power wastage (models KLP700 and KLP350x3)

Performed tests

Air discharges 4 kV � 8 kV 15 kV xx kV

Contact discharges 2 kV � 4 kV 8 kV xx kV

Via coupling planes � Horizontal � Vertical

Polarity � Positive � Negative

Set-up � Table-top Floor standing

Ambient temperature 21 °C

Relative Humidity air 49%

Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance was observed. Conclusion:

PASS

Page 22: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 22 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

5.2 Radiated EM field immunity During the test it is verified if the equipment under test has sufficient immunity against radiated electromagnetic fields. Walkie-talkies, radio transmitters, television transmitters, and telecommunication equipment including cellular telephones and other emitting devices, like industrial electromagnetic sources can generate these fields Requirements

Standard EN 61547

Basic standard EN 61000-4-3

Port Enclosure

Performance criterion A; Operation as intended

Frequency range 80 - 1000 MHz

Modulation 1 kHz – 80% AM

Fieldstrength 3 V/m

Performed tests

Frequency range 80 - 1000 MHz

Tested Fieldstrength 3 V/m

Dwell time 1 second

Test set-up Full Anechoic Chamber

Mode On mode with max. power wastage (models KLP700 and KLP350x3)

Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance was observed. Conclusion:

PASS

Page 23: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 23 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

5.3 Electrical Fast Transient immunity The EFT immunity test simulates disturbances by bursts of very short transients caused for example by switching off loads such as an AC motor or bouncing relay contacts. The transients are likely to disturb electronics but less likely to cause damage. Requirements

Standard EN 61547

Basic standard EN 61000-4-4

Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed.

Pulse characteristics 5/50 ns

Peak Voltage; Port 1kV; AC input power port

Repetition frequency � 5 kHz 2,5 kHz

Performed tests

Tested Voltage; Port 1kV; AC input power port

Mode On mode with max. power wastage (models KLP700 and KLP350x3)

Injection method � CDN Capacitive clamp Polarity � Positive � Negative

Set-up � Table-top Floor standing

Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance was observed. Conclusion:

PASS

Page 24: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 24 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

5.4 Surge transient immunity The surge transient immunity test simulates the surges that are caused by overvoltages due to indirect (induced) lightning transients. The pulse is a slow transient with high-energy contents and due to its long duration may cause damage to an unprotected EUT. Requirements

Standard EN 61547

Basic standard EN 61000-4-5

Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed. C; Temporary, self-recoverable loss of function is allowed.

Pulse characteristics 1,2/50 µs0,5

Peak Voltage; Port 0,5kV; AC input power port (line to line)

Performed tests

Tested Voltage; Port 0,5kV; AC input power port (line to line) Mode On mode max. power wastage (models KLP700 and

KLP350x3)

Polarity � Positive � Negative

Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance was observed. Remarks: Please see the detailed test data in the following page.

Page 25: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 25 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

EUT No. KLP350x3 Power supply 230 V 50 Hz Port AC input power port Result Pass

Coupling mode

Polarity Phase angle

Impulse Impulse voltage (kV)

Remarks

+ 0 5 0,5 A + 90 5 0,5 A + 180 5 0,5 A + 270 5 0,5 A - 0 5 0,5 A - 90 5 0,5 A - 180 5 0,5 A

L - N

- 270 5 0,5 A

+ 0 5 1,0 -- + 90 5 1,0 -- + 180 5 1,0 -- + 270 5 1,0 --

- 0 5 1,0 -- - 90 5 1,0 -- - 180 5 1,0 --

L - PE

- 270 5 1,0 --

+ 0 5 1,0 -- + 90 5 1,0 -- + 180 5 1,0 -- + 270 5 1,0 -- - 0 5 1,0 -- - 90 5 1,0 -- - 180 5 1,0 --

N - PE

- 270 5 1,0 --

A During the test no change of the luminous intensity shall be observed and the regulating control.

B During the test degradation is allowed. No change of operating state or stored data is allowed

Remark

C Temporary, self-recoverable loss of function is allowed.

Table 1

Page 26: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 26 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

EUT No. KLP700 Power supply 230 V 50 Hz Port AC input power port Result Pass

Coupling mode

Polarity Phase angle

Impulse Impulse voltage (kV)

Remarks(refer to table 1)

+ 0 5 0,5 A + 90 5 0,5 A + 180 5 0,5 A + 270 5 0,5 A - 0 5 0,5 A - 90 5 0,5 A - 180 5 0,5 A

L - N

- 270 5 0,5 A

+ 0 5 1,0 -- + 90 5 1,0 -- + 180 5 1,0 -- + 270 5 1,0 --

- 0 5 1,0 -- - 90 5 1,0 -- - 180 5 1,0 --

L - PE

- 270 5 1,0 --

+ 0 5 1,0 -- + 90 5 1,0 -- + 180 5 1,0 -- + 270 5 1,0 -- - 0 5 1,0 -- - 90 5 1,0 -- - 180 5 1,0 --

N - PE

- 270 5 1,0 --

Table 2

Conclusion:

PASS

Page 27: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 27 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

5.5 RF Conducted immunity During this test the immunity of the equipment for induced or conducted electromagnetic fields is checked. Fields generated by radio and other transmitters cause RF voltages in long cables like the mains network. This test reproduces these induced disturbing voltages by injecting them to the EUT via the cabling. Requirements

Standard EN 61547

Basic standard EN 61000-4-6

Performance criterion A; Operation as intended

Frequency range 0,15 – 80 MHz

Modulation 1 kHz – 80% AM

Test level; Port 3V; AC input power port

Performed tests

Tested level; Port 3V; AC input power port Mode On mode max. power wastage (model KLP350x3)

Frequency range 0,15 – 80 MHz Dwell time 1 second

Injection method � CDN-M2 EM clamp

Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance was observed. Conclusion:

PASS

Page 28: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 28 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

5.6 Power supply interruptions and dips Requirements

Basic standard EN 61000-4-11

Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed. C; Temporary, self-recoverable loss of function is allowed.

Standard EN 61547

C UNOM – 30% (10 periods) AC input power port

C UNOM – 100% (0,5 period)

Performed tests

Tested voltage AC input power port, 240 VAC Mode On mode max. power wastage (model KLP350x3)

UNOM – 30% (10 periods) AC input power port

UNOM – 100% (0,5 period)

Observations After the test the EUT functioned as intended. No unacceptable loss of performance was observed. Conclusion:

PASS

Page 29: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 29 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

6 IDENTIFICATION OF THE EQUIPMENT UNDER TEST The photograph shows the tested device.

Figure 4 Conducted Emission test setup

Page 30: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 30 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

Figure 5 Radiated Emission test setup

Page 31: EMC Test report for LED Power Supply, Models KLP350 ... Report/EMC Test Report of LED...EMC Test report for LED Power Supply, Models KLP350, KLP350x3 and KLP700 Guangzhou, date of

-page 31 of 31- 4302294.50

KQGZ-F-PC4-005 Version: 2.0

7 OPERATING MANUAL OF ELECTRONIC TRANSFORMER