emc test report - greentronic.de ce_emc_conformity- test... · ce emc conformity test report no :...
TRANSCRIPT
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 1 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
EMC TEST REPORT According to
Test Report No. : BWS-08-EC-0001
Equipment : Air cleaner
Model No : AIRVAX 33X2
Applicant : IDEAVAX Co., LTD 2F, soohyun B/D, 517-34, Shinsa-dong, Gangnam-gu, Seoul, Korea 135-888
Manufacturer : IDEAVAX Co., LTD 2F, soohyun B/D, 517-34, Shinsa-dong, Gangnam-gu, Seoul, Korea 135-888
Date of Incoming : January 2, 2008
Testing Start Date : January 3, 2008
Date Testing Complete : January 3, 2008
This report applies only to the product named in the title of this report manufactured at the location indicated. Test results apply only to the particular equipment and functionality described in this test report.
EN 55014-1: 2006 EN 55014-2: 1997+A1:2001 EN 61000-3-2: 2006
EN 61000-3-3: 1995+A1:2001+A2:2005
Prepared by : Reviewed by: No-Kyu, Ki /EMC Engineer BWS TECH INC.
Nam, Tae-hyun/Chief Engineer BWS TECH INC.
BWS TECH INC.
611-1, Maesan-ri, Mohyeon-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do 449-853, Korea TEL: +82-31-333-5997, FAX: +82-31-333-0017
http://www.bws.co.kr
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 2 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
TABLE OF CONTENTS
Pages
1. General Description of EUT 3~4
2. General Information of Test 5~7
3. Test Data
3.1 Power Line Conducted Emission Tests 8~12
3.2 Disturbance power Emission Test 13~16
3.3 Discontinuous disturbance Emission Tests 17~18
3.4 Power Frequency Harmonics and Flicker Emission Test 19~24
4. EUT Photographs 25~30
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 3 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
1. General Description of EUT
1.1 Applicant
Company Name : IDEAVAX Co., LTD
Address : 2F, soohyun B/D, 517-34, Shinsa-dong, Gangnam-gu, Seoul, Korea 135-888
Contact Person : Young-Rok, Choi/ Manager
Phone/Fax : Phone : +82-2-517-8012 Fax : +82-2-517-8016
1.2 Manufacture
Company Name : IDEAVAX Co., LTD
Address : 2F, soohyun B/D, 517-34, Shinsa-dong, Gangnam-gu, Seoul, Korea 135-888
Contact Person : Young-Rok, Choi/ Manager
Phone/Fax : Phone : +82-2-517-8012 Fax : +82-2-517-8016
1.3 Basic Description of EUT
Trade Name :
Product Name : Air cleaner
Model Name : AIRVAX 33X2
Serial Number : Prototype
Input Rating : AC 100-240, 50/60Hz, 0.5A DC 12V, 1A
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 4 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
1.4 Technical Description of EUT
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 5 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
2. General Information of Test 2.1 Test Facility
This test was carried out by BWS TECH Inc. Test Site Location : 611-1, Maesan-ri, Mohyeon-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do 449-853, Korea
TEL : +82-31-333-5997 FAX : +82-31-333-0017
2.2 Standard for Methods of Measurement
Basic Standard Description Test Result
EN55014-1: 2006 Requirements for household appliances, electric tools and similar apparatus Pass Fail
EN55014-2: 1997+A1:2001 Requirements for household appliances, electric tools and similar apparatus *NOTE
EN61000-3-2: 2006 Mains harmonics equipment up to 16A. Pass Fail
EN61000-3-3: 1995+ A1:2001+A2:2005 Voltage fluctuations equipment up to 16A. Pass Fail
*NOTE: This EUT contains category I, so immunity test should not be required.
2.3 Description of EUT Modification
The device tested is not modified anything, mechanical or circuits to improve EMI status during a test. No EMI suppression device(s) was added and/or modified during testing.
2.4 Variations covered by this report
-Model Difference: N/A
2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in full. Partial reproduction may only be made with the written permission of the BWS Tech Inc.
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 6 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
2.6 Test Conditions EUT Operating Mode EUT was tested according to the following operation modes provided by the specifications given by the manufacturer, and reported the worst emissions.
Operation Modes Worst Case Mode
High operating Mode
PASS/FAIL Criteria for Immunity Test
Criteria During Test After Test
A
Operate as intended No loss of function No degradation of performance No unintentionally transmit or change its actual operating state and stored data.
-. Operate as intended -. No loss of function -. No degradation of performance -. No loss of stored data or user programmable
functions
B
May show loss of function May show degradation of performance
-. Function shall be self recoverable -. Shall operate as intended after recovery -. No degradation of performance -. No loss of functions -. No loss of stored data or user programmable functions
C May be loss of function(one or more) -. Function shall be restored by the operator
control -. Shall operates intended after recovery
Table 1. Performance Criteria
Classification of Apparatus Category I: apparatus containing no electronic control circuitry Category II: Transformer toys, dual supply toys, mains powered motor operated appliances, tools, heating appliances and similar electric apparatus (for example—UV radiators, IR radiators and microwave ovens) containing electronic control circuitry with no internal clock frequency or oscillator frequency higher than 15 MHz. Category III: battery powered apparatus (with built-in batteries or external batteries), which in normal use is not connected to the mains, containing an electronic control circuitry with no internal clock frequency or oscillator frequency higher than 15 MHz. Category IV: all other apparatus covered by the scope of this standard. Note: -This EUT contains Category I.
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 7 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
Test System layout on EUT and peripherals Interface cable Power cable
2.7 Description of Test System (EMI) Type of Peripheral Equipment Used:
Description Model Name Serial No. Manufacturer Note
EUT AIRVAX 33X2 - IDEAVAX Co., LTD -
Type of Cables Used:
Device from Device to Type of Cable Length(m) Type of shield
EUT Adaptor - 1.8 Unshielded
Adaptor
EUT
Remote Control
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 8 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.1 Power Line Conducted Emission Tests
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz on the 100-240V AC power and return leads of the EUT according to the methods defined in European Standard EN55014-1 : 2006. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 3.1.5. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions.
3.1.1 Test Condition
Frequency Range of Test : 150 kHz to 30 MHz
Test Standard : EN55014-1 : 2006
Test Date : January 3, 2008
Temperature/Humidity/Pressure : 23°C / 42%
3.1.2 Test Standard
Limit (dBuV) Item Frequency Range (MHz) Quasi-Peak Average-Peak
0.15 ~ 0.5 66-56 59-46 0.5 ~ 5 56 46
Main Terminal Disturbance Voltage
(Main terminal) 5 ~ 30 60 50 3.1.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
TEST RECEIVER ESPI ROHDE&SCHWARZ 100063 11. 19. 2008
Conducted Cable N/A N/A N/A N/A
Artificial Main Network L3-25 PMM 1110K70403 08. 22. 2008
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 9 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.1.4 Test Result of Power Line Conducted Emission
Power Line Conducted Emission Test Results: PASS
Test data sheets follow.
Limit Reading EmissionLevel Margin Limit Reading Emission
Level Margin
[dBuV] [dBuV] [dBuV] [dBuV] [dBuV] [dBuV] [dBuV] [dBuV]
0.158 0.06 0.03 H 65.90 62.79 62.88 3.02 58.82 34.98 35.07 10.93
0.226 0.07 0.10 N 63.90 56.65 56.82 7.08 56.23 35.16 35.33 10.67
0.514 0.07 0.30 H 56.00 43.58 43.95 12.05 46.05 22.18 22.55 23.45
0.910 0.05 0.35 H 35.53 35.93 20.07 24.87 25.27 20.73
1.346 0.03 0.45 H 35.57 36.05 19.95 23.43 23.91 22.09
2.150 0.03 0.56 H 36.86 37.45 18.55 23.70 24.29 21.71
3.346 0.03 0.65 H 35.06 35.74 20.26 20.60 21.28 24.72
5.442 0.05 0.88 H 26.57 27.50 28.50 14.98 15.91 30.09
9.758 0.07 1.02 H 26.11 27.20 32.80 16.05 17.14 28.86
23.206 0.09 1.46 H 25.93 27.48 32.52 15.15 16.70 29.30
29.302 0.26 1.64 H 22.83 24.73 35.27 11.05 12.95 33.05
56.00 46.00
60.00 50.00
Average Mode
Phase[H/N]
Quasi-Peak Mode
Freq[MHz]
Correction
AMN C.L
Notes: 1. H : Hot Line , N :Neutral Line 2. Emission Level = Reading + Correction Factor 3. Margin = Limit - Emission Level 4. Measurements were performed at the AC Power Inlet of the host PC with the EUT plugged in the frequency band of
150kHz ~30MHz 5. Measurement uncertainty estimated at ±1.38 dB. 6. The measurement uncertainty is given with a confidence of 95.45 % with the coverage factor, k=2.
Tested by No-Kyu, Ki
EUT : AIRVAX 33X2
Input Voltage : AC 230V, 50Hz
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 10 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
PLOTS OF EMISSIONS
Test Mode: HOT Model Name: AIRVAX 33X2 Classification: EN55014-1
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 11 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
PLOTS OF EMISSIONS
Test Mode: NEUTRAL Model Name: AIRVAX 33X2 Classification: EN55014-1
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 12 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.1.4 Photographs of Power Line Conducted Emission Test Configuration
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 13 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.2. Disturbance Power Emission Tests Disturbance power emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 kHz according to the methods defines in EN55014-1 : 2006. The EUT was placed on a nonmetallic stand in a shielded room, 0.8 meter above the ground plane, Disturbance power is measured in accordance with clause 6, at all terminals.
3.2.1 Test Condition
Frequency Range of Test : 30 MHz to 300 MHz
Test Standard : EN55014-1 : 2006
Test Date : January 3, 2008
Temperature/Humidity/Pressure : 24 °C/ 42 %
3.2.2 Test Standard
Tools Frequency
range Household and similar
appliances Rated motor power not exceeding 700 W
Rated motor power above 700 W and not
exceeding 1000 W
Rated motor power above 1000 W
(MHz) dB (pW) Quesi-peak
dB (pW) Average
dB (pW) Quesi-peak
dB (pW) Average
dB (pW) Quesi-peak
dB (pW) Average
dB (pW) Quesi-peak
dB (pW) Average
Increasing linearly with the frequency from: 30 to 300
45 to 55 35 to 45 45 to 55 35 to 45 49 to 59 39 to 49 55 to 65 45 to 55
3.2.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
TEST RECEIVER ESPI ROHDE&SCHWARZ 100063 11. 19. 2008
Absorbing Clamp F-201-23-mm FCC 97 09. 01. 2008
Conducted Cable N/A N/A N/A N/A
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 14 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.2.4 Test Result of Radiated Emission
Disturbance power emissions Test Results : PASS
Test data sheets follow.
Quasi-peak Average Quasi-peak Average Quasi-peak Average
33.24 36.88 32.10 45.4 35.45 8.57 3.35
40.40 30.59 16.41 46.3 36.29 15.70 19.88
64.00 27.39 13.82 48.3 38.29 20.90 24.47
90.36 29.76 15.10 49.8 39.79 20.03 24.69
150.00 21.24 8.80 52.0 41.99 30.75 33.19
184.44 20.03 7.43 52.9 42.89 32.86 35.46
221.84 19.25 7.04 53.7 43.69 34.44 36.65
296.40 19.75 8.08 54.9 44.95 35.20 36.87
Margin[dB]Frequency
[MHz]
Reading [dBpW]
Limit[dBpW]
Notes:
1. Measurement uncertainty estimated at ±1.38 dB. The measurement uncertainty is given with a confidence of 95.45 % with the coverage factor, k=2.
Tested by No-Kyu, Ki
EUT : AIRVAX 33X2
Test distance : 6 m
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 15 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
PLOTS OF EMISSIONS
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 16 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.2.4 Photographs of Disturbance power Emission Test Configuration.
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 17 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.3. Discontinuous disturbance Emission Tests Discontinuous disturbance emissions form 148.5 kHz to 30 MHz were measured with a bandwidth of 9 kHz according to the methods defines in EN55014-1: 2006. The EUT was placed on a nonmetallic stand in a shielded room, 0.8 meter above the ground plane.
3.3.1 Test Condition
Frequency Range of Test : 148.5 kHz to 30 MHz
Test Standard : EN55014-1 : 2006
Test Date : January 3, 2008
Temperature/Humidity/Pressure : 24°C / 42%
3.3.2 Test Standard.
44 dB for N < 0.2, or
20 log(30/N) dB for 0.2 ≤ N < 30
3.3.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Date Use
EMC Analyzer E7403A HP US39150108 08. 22. 2008
Artificial Mains Network L3-25 PMM 1110K70403 08. 22. 2008
Conducted Cable N/A N/A N/A N/A
Tested by No-Kyu, Ki
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 18 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.3.4 Test Data
Test Data click 150 kHz 500 kHz 1.4 MHz 30 MHz click 150 kHz 500 kHz 1.4 MHz 30 MHz
1 O O O O 21 O O O O 2 O O O O 22 O O O O
3 O O O O 23 O O O O
4 O O O O 24 O O O O
5 O O O O 25 O O O O
6 O O O O 26 O O O O
7 O O O O 27 O O O O
8 O O O O 28 O O O O
9 O O O O 29 O O O O
10 O O O O 30 O O O O
11 O O O O 31 O O O O
12 O O O O 32 O O O O
13 O O O O 33 O O O O
14 O O O O 34 O O O O
15 O O O O 35 O O O O
16 O O O O 36 O O O O
17 O O O O 37 O O O O
18 O O O O 38 O O O O
19 O O O O 39 O O O O 20 O O O O 40 O O O O
Click Frequency 150 kHz 500 kHz 1.4 MHz 30 MHz Contin.Limit Lst 66 56 56 60
Click Rate O O O O Click Level Lc 44 44 44 44
L = Lc + Lst 110 100 100 104 Number Permissible of Click - - - -
Number over limit O O O O Passed Pass Pass Pass Pass
● = are the clicks above click limit Lc O = are the clicks not exceeding click limit Lc Lc = 20log (30/N) N < 0.2 (5min) + 44dB
N = Click /min 0.2 < N < 30 + Lc
Click = 10ms < C time <200 ms N > 30 (2sec) + 0dB
(Industry machine + 10dB)
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 19 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
3.4 Power Frequency Harmonics and Flicker Emission Tests
3.4.1 Test Procedure Power Frequency Harmonics Tests :
The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in Clause 7 of EN61000-3-2
Flicker Emission Tests :
The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of ±8% is achieved during the whole assessment procedure.
3.4.2 Test Condition
EUT : AIRVAX 33X2
Test Standard : EN61000-3-2: 2006 EN61000-3-3: 1995+A1:2001+A2:2005
Test Date : January 3, 2008
Temperature/Humidity/Pressure : 24°C / 41%
3.4.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Compliance Test system PACS-1 California Instruments 71980 N/A
AC POWER SOURCE 5001ix-CTS California Instruments 54549 N/A
3.4.4 Test Result of Flicker Emission Tests
Power Frequency Harmonics : PASS
Flicker Emission Tests : PASS
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 20 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
Harmonics – Class-A per Ed. 2.2 (2004-11)(Run time) incl. inter-harmonics EUT: AIRVAX 33X2 Tested by: BWS Tech. Test category: Class-A per Ed. 2.2 (2004-11) (European limits) Test Margin: 100 Test date: 2008-01-03 Start time: 오후 9:03:55 End time: 오후 9:14:05 Test duration (min): 10 Data file name: H-000259.cts_data Comment: AIRVAX Customer: IDEAVAX Co., LTD Test Result: Pass Source qualification: Normal Current & voltage waveforms
-0.6-0.4-0.20.00.20.40.6
-300-200-1000100200300
Cur
rent
(Am
ps)
Voltage (V
olts)
Harmonics and Class A limit line European Limits
0.00.51.01.52.02.53.03.5
Cur
rent
RM
S(A
mps
)
Harmonic #4 8 12 16 20 24 28 32 36 40
Test result: Pass Worst harmonic was #19 with 6.00% of the limit.
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 21 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
Current Test Result Summary (Run time)
EUT: AIRVAX 33X2 Tested by: BWS Tech. Test category: Class-A per Ed. 2.2 (2004-11) (European limits) Test Margin: 100 Test date: 2008-01-03 Start time: 오후 9:03:55 End time: 오후 9:14:05 Test duration (min): 10 Data file name: H-000259.cts_data Comment: AIRVAX Customer: IDEAVAX Co., LTD. Test Result: Pass Source qualification: Normal THC(A): 0.05 I-THD(%): 241.52 POHC(A): 0.017 POHC Limit(A): 0.251 Highest parameter values during test: V_RMS (Volts): 229.75 Frequency(Hz): 50.00 I_Peak (Amps): 0.425 I_RMS (Amps): 0.051 I_Fund (Amps): 0.020 Crest Factor: 8.410 Power (Watts): 4.1 Power Factor: 0.353 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.001 1.080 0.1 0.002 1.620 0.10 Pass 3 0.017 2.300 0.7 0.017 3.450 0.50 Pass 4 0.001 0.430 0.2 0.001 0.645 0.20 Pass 5 0.017 1.140 1.5 0.017 1.710 0.99 Pass 6 0.001 0.300 0.3 0.001 0.450 0.24 Pass 7 0.016 0.770 2.1 0.016 1.155 1.42 Pass 8 0.001 0.230 0.3 0.001 0.345 0.29 Pass 9 0.015 0.400 3.9 0.016 0.600 2.60 Pass 10 0.001 0.184 0.4 0.001 0.276 0.32 Pass 11 0.015 0.330 4.4 0.015 0.495 2.98 Pass 12 0.001 0.153 0.5 0.001 0.230 0.41 Pass 13 0.014 0.210 6.5 0.014 0.315 4.38 Pass 14 0.001 0.131 0.6 0.001 0.197 0.44 Pass 15 0.013 0.150 8.4 0.013 0.225 5.70 Pass 16 0.001 0.115 0.7 0.001 0.173 0.52 Pass 17 0.012 0.132 8.7 0.012 0.199 5.91 Pass 18 0.001 0.102 0.7 0.001 0.153 0.63 Pass 19 0.010 0.118 8.8 0.011 0.178 6.00 Pass 20 0.001 0.092 0.8 0.001 0.138 0.63 Pass 21 0.009 0.107 8.6 0.010 0.161 5.93 Pass 22 0.001 0.084 0.8 0.001 0.125 0.66 Pass 23 0.008 0.098 8.3 0.008 0.147 5.74 Pass 24 0.001 0.077 0.9 0.001 0.115 0.71 Pass 25 0.007 0.090 7.8 0.007 0.135 5.40 Pass 26 0.001 0.071 0.9 0.001 0.106 0.72 Pass 27 0.006 0.083 7.1 0.006 0.125 5.02 Pass 28 0.001 0.066 0.9 0.001 0.099 0.74 Pass 29 0.005 0.078 6.4 0.005 0.116 4.58 Pass 30 0.001 0.061 0.9 0.001 0.092 0.76 Pass 31 0.004 0.073 5.6 0.004 0.109 4.04 Pass 32 0.001 0.058 0.9 0.001 0.086 0.82 Pass 33 0.003 0.068 4.8 0.004 0.102 3.53 Pass 34 0.000 0.054 0.9 0.001 0.081 0.86 Pass 35 0.003 0.064 4.1 0.003 0.096 3.06 Pass 36 0.000 0.051 0.8 0.001 0.077 0.88 Pass 37 0.002 0.061 3.5 0.002 0.091 2.62 Pass 38 0.000 0.048 0.8 0.001 0.073 0.90 Pass 39 0.002 0.058 3.1 0.002 0.087 2.28 Pass 40 0.000 0.046 0.8 0.001 0.069 0.78 Pass
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 22 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
Voltage Source Verification Data (Run time) EUT: AIRVAX 33X2 Tested by: BWS Tech. Test category: Class-A per Ed. 2.2 (2004-11) (European limits) Test Margin: 100 Test date: 2008-01-03 Start time: 오후 9:03:55 End time: 오후 9:14:05 Test duration (min): 10 Data file name: H-000259.cts_data Comment: AIRVAX Customer: IDEAVAX Co., LTD. Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): 229.75 Frequency(Hz): 50.00 I_Peak (Amps): 0.425 I_RMS (Amps): 0.051 I_Fund (Amps): 0.020 Crest Factor: 8.410 Power (Watts): 4.1 Power Factor: 0.353 Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.191 0.459 41.57 OK 3 0.564 2.068 27.28 OK 4 0.056 0.459 12.17 OK 5 0.072 0.919 7.80 OK 6 0.053 0.459 11.47 OK 7 0.053 0.689 7.63 OK 8 0.041 0.459 8.83 OK 9 0.053 0.459 11.45 OK 10 0.036 0.459 7.88 OK 11 0.040 0.230 17.32 OK 12 0.038 0.230 16.40 OK 13 0.027 0.230 11.55 OK 14 0.024 0.230 10.44 OK 15 0.030 0.230 12.85 OK 16 0.026 0.230 11.17 OK 17 0.021 0.230 9.27 OK 18 0.027 0.230 11.90 OK 19 0.030 0.230 13.23 OK 20 0.027 0.230 11.96 OK 21 0.016 0.230 7.18 OK 22 0.018 0.230 7.64 OK 23 0.025 0.230 10.95 OK 24 0.015 0.230 6.57 OK 25 0.068 0.230 29.54 OK 26 0.016 0.230 7.11 OK 27 0.065 0.230 28.20 OK 28 0.015 0.230 6.37 OK 29 0.016 0.230 7.01 OK 30 0.015 0.230 6.61 OK 31 0.017 0.230 7.32 OK 32 0.013 0.230 5.49 OK 33 0.011 0.230 4.75 OK 34 0.009 0.230 3.81 OK 35 0.012 0.230 5.20 OK 36 0.009 0.230 4.08 OK 37 0.011 0.230 4.81 OK 38 0.009 0.230 3.82 OK 39 0.010 0.230 4.34 OK 40 0.014 0.230 6.23 OK
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 23 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
Flicker Test Summary per EN/IEC61000-3-3 (Run time)
EUT: AIRVAX 33X2 Tested by: BWS TECH. Test category: All parameters (European limits) Test Margin: 100 Test date: 2008-01-03 Start time: 오후 4:12:28 End time: 오후 6:12:49 Test duration (min): 120 Data file name: F-000257.cts_data Comment: AIRVAX Customer: IDEAVAX Co., LTD. Test Result: Pass Status: Test Completed Psti and limit line European Limits
0.25
0.50
0.75
1.00
Pst
16:22:48
16:32:48
16:42:48
16:52:48
17:02:48
17:12:48
17:22:48
17:32:48
17:42:48
17:52:48
18:02:48
18:12:48
Plt and limit line
0.20.30.40.50.6
Plt
18:1
2:4
8
Parameter values recorded during the test: Vrms at the end of test (Volt): 229.76 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%):0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.160 Test limit: 1.000 Pass
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 24 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
Highest Plt (2 hr. period): 0.160 Test limit: 0.650 Pass 3.4.5 Photographs of Power Frequency Harmonics and Flicker Emission Tests Configuration.
[Harmonics]
[Flicker]
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 25 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
4. EUT PHOTOGRAPHS [Front of EUT]
[Back of EUT]
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 26 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
[Label of EUT]
[Internal of EUT(Top)]
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 27 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
[Internal of EUT(Bottom)]
[Adapter Label]
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 28 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
[Front of Main board]
[Back of Main board]
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 29 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
[DC FAN Label]
[Front of Remote Control]
CE EMC Conformity Test
Report No : BWS-08-EC-0001 Page Number : Page 30 to 30
BWS TECH Inc. CE EMC Conformity Test
Issue Date : January 3, 2008
[Back of Remote Control]
[Remote Control battery]