emc ionix controlcenter 6.1 need to know · database version agent se 6.5.x se 7.0.x se 7.1.x...

19
1 © Copyright 2009 EMC Corporation. All rights reserved. How to be successful the 1 st time EMC Ionix ControlCenter 6.1 UB7 Need to know

Upload: others

Post on 10-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

1© Copyright 2009 EMC Corporation. All rights reserved.

How to be successful the 1st time

EMC Ionix ControlCenter 6.1

UB7 – Need to know

Page 2: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

2© Copyright 2009 EMC Corporation. All rights reserved.

Agenda

Changes in Agent Compatibility

Symmetrix Enginuity Support Managing Symmetrix Arrays

Solaris x86 Agents

UB7 & Solutions Enabler Database Support

Pre-UB7 Preparation Flow Chart

Pre-install checks of UB7 Extra Steps for Success

UB7 Installer Pre-checks & Restarting Flow Chart

Apply UB7 – Summary of Steps

Post UB7 Information

Page 3: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

3© Copyright 2009 EMC Corporation. All rights reserved.

Planning Starts Here…

What is your Starting point?

Select your

starting point

Upgrading

from

CC 6.0

CC 5.2

No

Yes

CC 6.1 is

already

installed

Check the Revision of the install media.

Only use the media marked as Rev A02

• This can be downloaded from Powerlink or

requested through Software Refresh

Caution: Do not use the media marked Rev A01

Yes

Gather the key information:

• Symmetrix Enginuity Version

• Database Versions

Installing

CC 6.1Yes

No

Page 4: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

4© Copyright 2009 EMC Corporation. All rights reserved.

Agent Compatibility

Backwards compatibility with 5.2_sp5 and 6.1 is with these agents only:– Master Agent

– Host Agents

– Oracle Agent

– Common Mapping Agent for Hosts and Databases

Any host that is using Invista storage must have the Host Agent patched to UB7 version or later.

All other agents must be at UB7 or later

Page 5: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

5© Copyright 2009 EMC Corporation. All rights reserved.

Symmetrix Enginuity Support

Symmetrix and SDM Agent are no longer backwards compatible

Symmetrix Enginuity Support adheres to the EMC Support Matrix – Reference Table 23 of the ControlCenter Support Matrix, rev A18 and later

– There is no support for these dropped versions of Enginuity; 5265, 5266,5267,5566, 5669, 5670

Enginuity 5670 Risk Statement– Symmetrix with 5670 will discover with UB7 Symmetrix Agent and SE 7.1

– This Symmetrix (5670) can be discovered, but no support will be provided.

– This Enginuity version needs to be upgraded as soon as possible to the targeted version.

Page 6: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

6© Copyright 2009 EMC Corporation. All rights reserved.

Managing Symmetrix Arrays

The Symmetrix and SDM agents follows the Solutions Enabler supported Enginuity versions.

UB7 requires Solutions Enabler 7.1

Observe Enginuity Support

Symmetrix and SDM must be upgraded to the UB7 or later version

SMC 7.1 is required for active management of Symmetrix Arrays.

Starting with Enginuity 5874 - SMC is installed on the Array’s Service Processor

SMC scalability is 10 Arrays or up to 80k devices.

Gatekeeper requirements – P&S, (November 2009 Rev A11) Guideline A11 on page 43

Symmetrix Management with SMC, Symmetrix Storage Agent and SDM Agent

All Arrays

running 5567,

5568,5671 or

higher

All other versions of

Enginuity not listed

above is not

supported and must

be upgraded to the

target level

Gather Databases

versions being

monitored

Yes

No

Gather the key information:

• Symmetrix Enginuity Version

• Database Versions

Solutions

Enabler 7.1 is

required

No Support

Page 7: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

7© Copyright 2009 EMC Corporation. All rights reserved.

UB7 & Solutions Enabler Database Support

Gather Databases

versions being

monitoredThe Common Mapping Agent could be

5.2.0.5.x, 6.0.0.x.x and 6.1.0.x.x versions

Sybase 15.0.3 is supported on AIX with

Solutions Enabler 7.1 (AQP – Q1/2010)

Proceed after all the

conditions stated

here are understood

and/or planned for

Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x

OracleSee Table 41 of

Support Matrix

Oracle Agent +

SEPre-UB5 Only Yes (UB5) Yes

Oracle ASMSee Table 41 –

Footnote A

Oracle Agent +

SENo No Yes

Sybase 12.5 CMA + SE Pre-UB5 Only Yes (UB5) HP-UX, AIX, Solaris

Sybase 15.0.3 (Q1/2010) CMA + SE No No HP-UX, AIX, Solaris

SQL Server 2000 Sp3, 2005 CMA + SE Pre-UB5 Only Yes (UB5) Yes

UDB DB2 7.1 - 8.2 CMA + SE Pre-UB5 Only Yes (UB5) Yes

Informix 7.3, 9.1, 9.4 CMA + SE Pre-UB5 Only No No

Informix

Informix DB is no longer support by SE 7.x

For continued support is only through a pre-UB5

CMA and Solution Enabler 6.5

Plan for this support before Upgrading to UB7

Yes

No

Page 8: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

8© Copyright 2009 EMC Corporation. All rights reserved.

Page 9: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

9© Copyright 2009 EMC Corporation. All rights reserved.

Select your

starting point

Upgrading

from

CC 6.0

CC 5.2

No

Yes

CC 6.1 is

already

installed

Check the Revision of the install media.

Only use the media marked as Rev A02

• This can be downloaded from Powerlink or

requested through Software Refresh

Caution: Do not use the media marked Rev A01

Yes

UB7 Preparation Flow Chart

Installing

CC 6.1Yes

No

All Arrays

running 5567,

5568,5671 or

higher

All other versions of

Enginuity not listed

above is not

supported and must

be upgraded to the

target level

Yes

No

Gather the key information:

• Symmetrix Enginuity Version

• Database Versions

Gather Databases

versions being

monitoredThe Common Mapping Agent could be

5.2.0.5.x, 6.0.0.x.x and 6.1.0.x.x versions

Sybase 15.0.3 is supported on AIX with

Solutions Enabler 7.1 (AQP – Q1 2010)

Proceed after all the

conditions stated

here are understood

and/or planned for

Informix

Informix DB is no longer support by SE 7.x

For continued support is only through a pre-UB5

CMA and Solution Enabler 6.5

Plan for this support before Upgrading to UB7

Yes

No

Solutions

Enabler 7.1 is

required

No Support

Page 10: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

10© Copyright 2009 EMC Corporation. All rights reserved.

Pre-install checks for UB7

Download the following patches from Powerlink:

– UB7 – CC_4673

– Backup/Restore Scripts – CC_4563

– MRLK7.1.0 – CC_4718

– STS Repository OCPU – April 09 CC_4601 or later

– ControlCenter Repository OCPU – April 09 CC_4603 or later

Check is if SSL is disabled

– If ControlCenter components are not functioning after the UB is applied, the SSL state may be the cause.

– Run lsnrctl status

If port is 1575 – SSL is enabled

If port is 1521 – SSL is disabled

Verify ample Disk Space to applying UB7

– UB7 has a 8 GB free space requirement which is checked before installing UB7

Create a snap-shot for a roll-back

– Always create a copy of ControlCenter directories for before upgrading or patching (UBs and OCPUs)

– Install CC_4563 (Backup/Restore Scripts)

– Follow the instructions for taking a snap-shot of the ControlCenter directory and OS settings

Step for success…

Page 11: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

11© Copyright 2009 EMC Corporation. All rights reserved.

Extra Steps for Success

• Check the security settings of the ewallet.p12 file on each host containing a ControlCenter or StorageScope Repository

• Add administrators if not present, run this command

• cacls %ECC_INSTALL_ROOT%\dbsafe\ewallet.p12 /e /g Administrators:F

• This is now handled automatically with the A02 Install Media

• Validate access to the Oracle Databases• Run ecc_getversion (confirms health of Repository database)

• Run emcsts_getversion (confirms health of StorageScope database)

• Login as local ECCADMIN with Local Administrator rights

• Update Bundles can be installed using Terminal Services• Make sure all other Terminal Sessions are logged off and disconnected

• Make sure all other Command Prompt Windows and Explorer windows are closed.

Page 12: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

12© Copyright 2009 EMC Corporation. All rights reserved.

Page 13: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

13© Copyright 2009 EMC Corporation. All rights reserved.

UB7 Installer Pre-checks & Restarting Flow Chart

Check for 8 GB of free space on the ControlCenter Drive

Handling a upgrade failure (documented on page 10 of the UB7 Readme)

Installer Pre-Upgrade

Validation Checks

Passed

Yes

No

Open log file

and review

the cause of

the failure

Repository Pre-Upgrade Validation failed.

Please review <log_file>.

Aborting upgrade

Correct the

failure

condition

Open log file

and review

the cause of

the failure

Error upgrading database.

Please review <log_file>.

Please contact customer service

Regarding this upgrade failure.

Contact

Customer

Service

Apply patch / fix

provided by CS

Select OK on

original pop-up

message

Continue

Upgrading

Would you

like to retry the

database

upgrade?

Abort Installer

Roll-back is

required

Yes

No

WARNING: Locked files/folders were encountered while trying to back up <directory>

Would you like to try again? Yes/No

• Yes - The process locking the files needs to finish or be terminated before continuing

Page 14: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

14© Copyright 2009 EMC Corporation. All rights reserved.

Apply UB7 - Summary of Steps

Run the UB7 InstallShield

Install time is 1 to 2 hours

Expect long pauses during the process

Monitor CPU Time activity by watching the Oracle.exe process in Task Manger

For distributed Infrastructures

1. Apply UB7 completely to the Server/Repository host

2. Apply UB7 simultaneous to:

1. StorageScope Host

2. Stores

3. Performance Manager

3. Upgrade the Console

Install the MRLK7.1 (CC_4718)

Take a snap-shot of ControlCenter using CC_4563– CD to <drive>:%ECC_INSTALL_ROOT%\HF4563

Apply the OCPU patches (Latest Oracle Security Patch Update is available on Powerlink)

1. ControlCenter Repository OCPU – April 09 CC_4603 or later

2. STS Repository OCPU – April 09 CC_4601 or later

Take a snap-shot of ControlCenter using CC_4563 (Refer to the Readme)

– CD to <drive>:%ECC_INSTALL_ROOT%\HF4563

Page 15: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

15© Copyright 2009 EMC Corporation. All rights reserved.

Post UB7 Information

Upgrading the CLARiiON Agent - Workaround– UB5 to UB7 only, CLARiiON upgrade may fail - does not happen all the time

– In case of failure:

1. Stop the CLARiiON Agent

2. Launch Task Manager – Show Processes

3. Terminate the NaviSECCLI.exe process

4. Upgrade the CLARiiON Agent from the console

CLARiiON Configuration Alerts (FLARE 26)

– Alerts disappear in the Alerts View after a few seconds

– To check for CLARiiON Alerts – Review in Alert History

CLARiiON Virtual Provisioning Alert (FLARE 28)

– Thin Pool % Full Threshold Alert

– No other support for CLARiiON Virtual Provisioning

CLARiiON FLARE 29 not supported with UB7– Support will be provided with a patch

Page 16: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

16© Copyright 2009 EMC Corporation. All rights reserved.

Post UB7 Information

Download the ControlCenter UB7 Native Install packages from Powerlink– Available January 2010, post UB7 GA

– Now includes the Oracle, CMA, Symmetrix and SDM Agents

– These NI packages will handle fresh install, agent upgrade, and agent patch functionality

Solaris x86 Agents– New platform support, Master and Host Agents ONLY

– Available only through the UB7 Native Install Package

– Solaris x86 agents will not be added to the Media Repository

Console– The initial start-up of the console may take an extended time to initialize. This could

take up to 5-minutes or longer to complete the process

– This will only happen once, per installed/upgraded console instance

Page 17: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

17© Copyright 2009 EMC Corporation. All rights reserved.

Post UB7 Information

StorageScope Service Level/Tiering– LUN tagging via “Apply Changes” may not work

– Deviceprotection column may not be populated, if a specific sequence of actions is performed (See CC 6.1 Release Notes updated for UB7 for details)

– Running the ETL process in both cases above will resolve the issue

– Service Level/Tiering is not supported for IBM ESS arrays discovered with SMI-S

StorageScope Repository installed on customer supplied Oracle instance– Support for this option has been dropped

Oracle ASM Console Support– Tree, Properties, Relationships and Free Space Views

Oracle ASM StorageScope Support– Database capacity is found in the STS ASMDiskGroup field

Page 18: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle

18© Copyright 2009 EMC Corporation. All rights reserved.

Post UB7 Information

Windows Vista and Windows 7 Support– Added OS support for Console – Windows Vista and Windows 7

Performance Manager GUI Client is not supported

Windows 2008 R2 Support– Console only, Performance Manager GUI Client is not supported

– ControlCenter Agents

– Infrastructure components are not support

Watch for support 1H2010

Windows 2008 Hyper-V– Master and Host Agents only

Page 19: EMC Ionix ControlCenter 6.1 Need to know · Database Version Agent SE 6.5.x SE 7.0.x SE 7.1.x Oracle See Table 41 of Support Matrix Oracle Agent + SE Pre-UB5 Only Yes (UB5) Yes Oracle