elevator addition river east collegiate - … · standard range. .2 2.12.4 provide ... matt borody,...

6
141 St. Anne’s Road, Winnipeg, MB 260-8 th Street, Brandon, MB Elevator Addition RIVER EAST COLLEGIATE Winnipeg, Manitoba River East Transcona School Division #2293 Addendum No. 3 – June 30, 2017 This addendum shall form part of and be included in the original contract drawings and specifications. No consideration shall be allowed for extras to the contract due to failure of the contractor or sub-contractor familiarizing themselves with this addendum. ARCHITECTURAL SPECIFICATION 1. Refer to Specification Section 01 23 00 Alternates: 1. Add Alternate No. 2, Composite Wall Panels as follows: .1 Base Bid: Refer to Specification Section 07 42 43 Composite Wall Panels .2 Alternate: Revise AL13 Architectural Panels to Alcotex Composite Panels .3 Add: $____________ or Deduct: $____________. 2. Refer to Specification Section 04 10 00 Masonry Units and Mortar: 1. Delete Section 2.2.1 and add the following: 2.2.1 Burned Clay Brick, as manufactured by Alsip’s, conforming to CSA- A82.1 and ASTM C216. Utility size: 92mm deep x 92 mm thick x 295mm long Page 1 of 6

Upload: vananh

Post on 18-May-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

141 St. Anne’s Road, Winnipeg, MB 260-8th Street, Brandon, MB

Elevator Addition RIVER EAST COLLEGIATE

Winnipeg, Manitoba

River East Transcona School Division

#2293

Addendum No. 3 – June 30, 2017

This addendum shall form part of and be included in the original contract drawings and specifications. No consideration shall be allowed for extras to the contract due to failure of the contractor or sub-contractor familiarizing themselves with this addendum.

ARCHITECTURAL SPECIFICATION 1. Refer to Specification Section 01 23 00 Alternates: 1. Add Alternate No. 2, Composite Wall Panels as follows:

.1 Base Bid: Refer to Specification Section 07 42 43 Composite Wall Panels

.2 Alternate: Revise AL13 Architectural Panels to Alcotex Composite Panels

.3 Add: $____________ or Deduct: $____________.

2. Refer to Specification Section 04 10 00 Masonry Units and Mortar: 1. Delete Section 2.2.1 and add the following:

2.2.1 Burned Clay Brick, as manufactured by Alsip’s, conforming to CSA- A82.1 and ASTM C216. Utility size: 92mm deep x 92 mm thick x 295mm long

Page 1 of 6

2. Add the following: .1 2.2.3 Colour: Yankee Hill Dark Ironspot Smooth as approved equal. .2 2.2.4 Colour: Charcoal Smooth by Yankee Hill as approved equal. .3 2.2.5 Colour: Capital Ironspot Smooth by Yankee Hill as approved equal. 3. Refer to Specification Section 04 20 00 Masonry Procedures:

1. Delete reference to “silicone rubber based sealant” in 2.1.11 4. Refer to Specification Section 08 71 00 Finish Hardware and revise Door Hardware

Schedule for Doors D103 and D104, see attached Hardware Schedule. 5. Refer to Specification Section 08 71 00, Door Hardware Schedule and add: .1 Gyro Tech GT 8500 and Gyro Tech GT710 as approved equal. 6. Refer to Specification Section 09 21 16 Gypsum Board and Room Finish schedule and add the following note: “ALL GYPSUM WALLBOARD ON WALL SURFACES IN THE PROJECT SHALL BE ABUSE RESISTANT TYPE” 7. Refer to Specification Section 09 65 16 Resilient Sheet Flooring 1. Add the following: 2.1.1.3 Tarket/Johnsonite iQ Optima – Full colour Range as accepted equal. 8. Refer to Specification Section 10 95 00, Miscellaneous Specialties: 1. Add the following:

1. 2.8.2 Joint Covers InPro joint covers as accepted Equal. .1 103 Series Surface Mount, type A01 and A02 (floor to floor, floor to wall) .2 811 Series, type A07 and A09 (wall to wall, ceiling to wall)

2. Revise the following: 1. Delete item 2.12.2 and 2.12.4 and add the following:

.1 2.12.2 Style: Optima Semi-bold, fabricated channel aluminum, anodized or baked enamel finish, colour to be selected from standard range.

.2 2.12.4 Provide three (3) numbers, 18” high.

ARCHITECTURAL DRAWINGS

A0.1 1. Delete Wall type 3.

Page 2 of 6

A1.0 1. Revise Site Plan Note 5 to read:

“EXISTING BIKE RACK(S) TO BE CAREFULLY REMOVED AND RELOCATED, SITE CONFIRM LOCATION WITH OWNER. REFER TO DEMOLITION PLANS FOR EXTENT OF CONCRETE PAD DEMOLITION. PROVIDE NEW CONCRETE PAD WITH SIMILAR DIMENSIONS FOR BIKE RACK(S). FINAL LOCATION OF THE CONCRETE PAD TO BE COORDINATED WITH OWNER.”

A7.0 1. Revise all dual pane fire rated safety glazing references to single pane fire rated safety

glazing on all interior doors and borrowed lites where 1 hour rating is required. MECHANICAL/ELECTRICAL 1. See attached Addendum No. 02ME, dated June 27, 2017

Page 3 of 6

Page 4 of 6

River East Collegiate Winnipeg, MB AllEGION

FINISH HARDWARE 08 7100 Draft- Revised - Final

2

2

2

1

2

2

2

2

2

2

2

2

2

1

Heading 03

1 PR DOOR(S) 103 VESTIBULE I LOBBY

21914 X 2134 X 45 X HMO X PSF X 45MIN

Fixed HM Mullion

Each Assembly to have:

EA CONT. HINGE 700 630 IVE

EA FIRE EXIT HARDWARE 98-L-BE-F-06 626 VON

EA ELECTRIC STRIKE 6111 FSE 630 VON

EA OH STOP 100S 630 GLY

EA SURFACE CLOSER 4040XP 689 LCN

EA TOP JAMB MTG PLATE 4040XP-18T J 689 LCN

EA SURF. AUTO OPERATOR 9542 MS ANCLR LCN

EA ACTUATOR, WALL MOUNT 8310-852 630 LCN

EA KICK PLATE 8400 254MM X 40MM LOW B-CS 630 IVE

EA SEAL W-22 TO SUIT OPENING BLK KNC

EA FIRE/LIFE MAG HOLD OPEN SEM7820 689 LCN

Free Egress at all times. Pressing Push Bar retracts latch bolts. Latch bolt retracted by lever at all times. Electric strike is released when power is applied (Fail Secure). Self-Closing. Magnetic Hold open connected to smoke/fire alarm panel and will release when alarm condition activated.

Heading 04

PR DOOR(S) 104 VESTIBULE I LOBBY

21914 X 2134 X 45 X HMO X PSF X 45MIN

Each Assembly to have:

EA CONT. HINGE 700 630 IVE

EA REMOVABLE MULLION KR9954 689 VON

EA MORTISE CYLINDER 20-001 114 626 SCH

EA FIRE EXIT HARDWARE 98-L-BE-F-06 626 VON

EA OH STOP 100S 630 GLY

EA SURFACE CLOSER 4040XP EDA 689 LCN

EA KICK PLATE 8400 254MM X 40MM LOW B-CS 630 IVE

EA SEAL W-22 TO SUIT OPENING BLK KNC

Page 5 of 6

River East Collegiate Winnipeg, MB ALLEGION

2 EA FIRE/LIFE MAG HOLD OPEN SEM7820

FINISH HARDWARE 08 7100 Draft- Revised - Final

689 LCN

Free Egress at all times. Pressing Push Bar retracts latch bolts. Latch bolt retracted by lever at all times. Self-Closing. Magnetic Hold open connected to smoke/fire alarm panel and will release when alarm condition activated.

A d d e n d u m

Date: June 27, 2017

210-1821 Wellington Avenue

Winnipeg, Manitoba

R3H 0G4

Phone (204) 779-7900

Fax (204) 779-1119

www.mcw.com

Project Name: River East Collegiate Elevator

Addition

Project No.: 10965

Client: MCM Architects Inc. ADD No.: 02ME

To: MCM Architects Inc. Page No.: 1 of 1

Attention: Aleksandr Olivson Office: Winnipeg

Email: [email protected] From: Anthony Schoenfeld, P.Eng. Matt Borody, EIT

Distribution: MCM – Rob Obirek

MCW – Ken Isaak

In accordance with the drawings and specifications, provide in the tender all costs required to complete the work including items as listed

below:

RE: MECHANICAL

1. The following manufacturers shall be considered equal:

a. Submersible pump: Little Giant

b. Exhaust fans: Soler and Palau

RE: ELECTRICAL – DOOR HOLD OPENS

1. Drawing E2.0

a. Provide magnetic door hold open on vestibule doors D103 and D104 wire and

connected to new 15A/1P circuit breaker, circuit EV-37, utilizing #12 RW90 wire in

3/4” conduit. Wire and connect door hold opens to suitable zone in fire alarm

system. Coordinate location of magnetic hold opens with architectural.

b. Provide one (1) smoke detector within 1.5m of either side vestibule doors.

ATS/MJB/sj

Page 6 of 6