electronic measuring and calibration instruments · electronic measuring and calibration...
TRANSCRIPT
Quality by tradition
Electronic Measuringand Calibration Instruments
2
Temperature calibratorsTP Basic 11 - 20
TP Solid 22 - 38
TP Premium 40 - 50
Accessoires 54
TT Scan 55 - 58
Pressure calibratorsPneumatic pressure pumps 64 - 65
Hydraulic pressure pumps 66 - 68
Hydraulic pressure generators 69
Digital pressure gauges 74 - 83
Accessoires 84 - 85
Pressure calibrators 86 - 89
SimulatorsMonofunction simulators 98 - 103
Multifunction simulators 104 - 109
Calibration servicesPurpose of calibration 116 - 117
Overview measuring values 118 - 119
Scope of accreditation 120 - 121
Hand-held instrumentsSeries MH 124 - 139
Series IR 140 - 147
Controllers and indicatorsControllers, series CON 154 - 171
Indicators, series IND 172 - 175
Digital thermometersSeries DiTemp 182 - 189
Series SolarTemp 190 - 197
KombiTemp®
Head form B 206 - 208
Head form J 209
Cable socket, angle type 210 - 213
Temperature sensorsMachinery and plant engineering 220 - 241
Maritime sector and shipbuilding 242 - 261
Heating and air-conditioning 262 - 277
Pressure sensors and pressure switchesRelative pressure 282 - 287
Absolute pressure 288 - 291
Difference pressure 292 - 294
Level measurement 295 - 297
Pressure switches 298 - 301
Temperature transmittersAnalogue transmitters 306 - 309
Programmable transmitters 310 - 311
Find all products andcatalogue updateson catalogues.sika.net
UPDATES ONLINEEVERY 4 MONTHS
Quality by tradition
Mechanical MeasuringInstruments
Quality by tradition
Flow Measuring Instruments
Quality by tradition
Electronic Measuringand Calibration Instruments
33
TemperatureStandard Signals
Pressure
% r.F.
°C°F
bar
mbarpsi
ΩmA
Electronic Measuring and Calibration Instruments
Our electronic instruments and calibration equipment product area features instruments with long-term reliability, innovative
calibration technology, and a comprehensive range of services from our own DKD laboratory for temperature, pressure and
standardised electrical signals.
Tried and tested components for instrumentation and control equipment and systems help our customers ensure the consistent
long-term quality of their products and the efficiency of their production processes. Our strength is our flexibility in developing
customised solutions, based on our wealth of experience.
4
4
5
Pressure calibrators
Simulators
Calibration services
Hand-held instruments
Controllers and indicators
Digital thermometers
KombiTemp®
Temperature sensors
Pressure sensors and pressure switches
Temperature transmitters
Temperature calibrators
6
7
MF
TEMPERATURE CALIBRATORS
J TP Basic
J TP Solid
J TP Premium
J Accessories
J TT-Scan
DS_Temperature_calibrators 05/2014
Including products with:
8
For industry and service
Good reasons for a calibration
• Maintain consistently high product quality
• Meet industry standards and legal regulations
• Optimize processes and boost productivity
• Avoid unscheduled downtime
Temperature sensors are subject to mechanical, thermal and chemical stress. This results in a drift the longer the sensors are in use. Only the regular calibration of the sensors provides information on the difference between the actual temperature and the measured temperature and makes the specific drift visible. In measuring tasks, readings are often taken without regard to the fact that every display value contains an error. These measured errors are probably still negligible in private applications, but in industrial applications even the smallest inaccuracy can lead to production errors, for instance.
9
Calibration with SIKA
Dry block calibrators and micro calibration baths are used to check and calibrate a wide range of temperature measuring instruments and temperature sensors. Mechanical, electro-mechanical or electronic measurement equipment can be checked with ease. The following can be tested directly:
• Contact-based immersion or surface temperature sensors
• Sensors with special shapes and sizes
• Non-contact infrared instruments and thermal imaging cameras
The compact and robust SIKA instruments are easy to transport, simple to use and offer all the features required for the specific test. Our instruments are already standard in many development, research and testing labs, testing and inspection departments and in the production and manufacturing sector.
DEUTSCHER KALIBRIERDIENST
Dr. Siebert & Kühn GmbH & Co. KG * Struthweg 7-9 * D-34260 Kaufungen * Telefon: 0 56 05/ 8 03 - 0 * Fax: 0 56 05/ 803 - 54/ 60
Kalibrierlaboratorium für thermodynamische und elektrische Messgrößen/ Calibration laboratory for pressure and electrical measuring instruments
Akkreditiert durch die / accredited by the
Akkreditierungsstelle des Deutschen Kalibrierdienstes
Labor Messtechnik Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 D-34260 Kaufungen
DKD-K-13901
000086
Kalibrierschein Kalibrierzeichen DKD-K- 13901
Calibration certificate Calibration mark 2011-04
Gegenstand Object
Multifunktions-Temperaturkalibrator - Trockenblockfunktion (DB) -
Hersteller Manufacturer
Dr. Siebert & Kühn GmbH & Co. KG D-34260 Kaufungen
Typ Type
TPM165S-U
Fabrikat/Serien-Nr. Serial number
5904245
Auftraggeber Customer
Auftragsnummer Order No.
655 578
Anzahl der Seiten des Kalibrierscheines Number of pages of the certificate
3
Datum der Kalibrierung Date of calibration
2011-04-21
Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Über-einstimmung mit dem Internationalen Einheitensystem (SI). Der DKD ist Unterzeichner der multi- lateralen Übereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI). The DKD is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object recalibrated at appropriate intervals.
Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmigung sowohl der Akkreditierungsstelle des DKD als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift und Stempel haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the Accreditation Body of the DKD and the issuing laboratory. Calibration certificates without signature and seal are not valid.
Stempel Seal
Datum Date
Stellv. Leiter des Kalibrierlaboratoriums Deputy Head of the calibration laboratory
Bearbeiter Person in charge
Dr. Siebert & Kühn GmbH & Co. KG · Struthweg 7 - 9 · 34260 Kaufungen Telefon: (05605) 803-0 · Telefax: (05605) 803-54 / 60 · Telex: 99717 sika d
SAMPLE
Works Calibration Certificate 2009-08
Instument: Precision-Temperature-Calibrator Type: TP17650M Range: RT to 650 °C Serial-No.: 5908022 Order-No.: Customer: Used standards and devices: Reference, Pt100, SN ASL-18, 2338 DKD-K-09701/ 2008-03 DMM Keithley,SN 857117, 0003 DKD-K-13901/ 2008-01 Results:
Reading Set value Deviation[°C] [°C] [°C]100 99,898 0,102200 199,806 0,194300 299,864 0,136400 399,892 0,108500 500,088 -0,088600 600,035 -0,035650 649,999 0,001
The deviations are within the specified tolerances of ± 0,2 % F. S.
electronic
10
Temperature calibrator requirements
Calibration task and operation locationsA temperature calibrator needs to meet a wide range of requirements: as a portable device, it has to cope with frequently changing operation locations in the test bay or in production, while being equally suitable for stationary use in the measuring workshop and testing and inspection laboratory. For this reason, the instruments must be lightweight and handy for quick and easy use on site. The weight and size are determining factors here. Furthermore, instrument durability also plays an important role.
Temperature rangeTemperature sensors should be calibrated at the temperature point at which they are used. This means that the temperature calibrator must be able to cover the process temperatures of the temperature sensor under calibration and, in particular, generate the main test points. SIKA offers several temperature calibrators to cover the range from -55 °C to 1300 °C.
Efficiency and flexibilityThe time and personnel required to perform the calibration task is a key index for gauging efficiency. The more efficiently things are done, the faster the return on investment in a temperature calibrator. Intuitive operation with clear displays that provide all the necessary information at a glance, along with the calibration volume and the associated re-cooling and cooling times, primarily determine the speed of the calibration. Another time-saver: a large-diameter test item holder that enables several temperature sensors to be calibrated simultaneously.
Reliable system accuracyVarious tests and measurement uncertainty appraisals as defined in the guidelines of the German Calibration Service (DKD) are performed during the production of SIKA calibrators. The measurement results are documented in comprehensive examination reports, thereby ensuring a reliable, high degree of system accuracy.
TraceabilityInstruments and measuring equipment become worn from constant use. It is unavoidable that equipment ages and measured values drift as a result. Regular inspection with a factory calibration standard is absolutely essential and can be performed easily with a SIKA temperature calibrator as the calibration standard.
ServicesExperienced and professional consultants visit you directly on site with demo instruments, thereby ensuring you receive top-quality customer care. Furthermore, SIKA also offers a wide array of services which can generally only be performed efficiently by the manufacturer, such as recalibration, adjustments and repairs. This increases the availability of the temperature calibrators and cuts cost.
11
TP Basic seriesThe temperature calibrators in the TP Basic series have been developed for direct on-site use. With these instruments the focus is on efficiency and portability. The easy-to-use design and automatic functions have been carefully selected to facilitate operation. The result: quick, simple and efficient temperature calibrators that do not compromise on quality.
Dry block function
The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.
Adapter sleeve
Some of the dry block calibrators have a large 60 mm block borehole and can hold several test items at once.
12
Technical data
Type TP 17 200
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-55...200 °C±0.4 °C ±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -60...200 °C
Resolution 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 12.5 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 600 VA
Type TP 17 200
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• DKD certificate
• Works certificate
TP 17 200
The TP 17 200 temperature calibrator, which is also known as TP COOL, works in a temperature range from -55 to 200 °C.
13
Technical data
Type TP 17 165 M
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±1 °C±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• DKD certificate
• Works certificate
TP 17 165 M
Type TP 17 165 M
14
Technical data
Type TP 17 165
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.4 °C±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0,1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• DKD certificate
• Works certificate
TP 17 165
Type TP 17 165
15
Type TP 17 166 Technical data
Type TP 17 166
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.4 °C±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• DKD certificate
• Works certificate
The TP 17 166 temperature calibrator model has a very large calibration volume.
TP 17 166
16
Type TP 18 200 ETechnical data
Type TP 18 200 E
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...200 °C±1 °C±0.1 °C60...100 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 18 mm / depth 100 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...200 °C
Resolution 1 °C
General data
DimensionsJ WidthJ HeightJ Depth
220 mm96 mm230 + 50 mm
Weight Approx. 4 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz, optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 220 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• DKD certificate
• Works certificate
TP 18 200 E
17
Technical data
Type TP 17 450
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...450 °C±0.6 °C±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...450 °C
Resolution 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 2000 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• DKD certificate
• Works certificate
TP 17 450
The TP 17 450 temperature calibrator model has a very large calibration volume.
Type TP 17 450
18
Technical data
Type TP 17 650 M
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...650 °C±1 °C±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...650 °C
Resolution 1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
TP 17 650 M
Type TP 17 650 M
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• DKD certificate
• Works certificate
19
Type TP 17 650 Technical data
Type TP 17 650
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...650 °C±0.8 °C±0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...650 °C
Resolution 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• DKD certificate
• Works certificate
TP 17 650
20
Type TP 18 850 ETechnical data
Type TP 18 850 E
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...850 °C±1 °C±0.1 °C60...100 mm or 160...200 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 18 or 28 mm / depth 100 or 200 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...850 °C
Resolution 1 °C
General data
DimensionsJ WidthJ HeightJ Depth
430 mm190 mm410 + 50 mm or 510 + 50 mm
Weight Approx. 14 kg or 16 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 2000 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• DKD certificate
• Works certificate
TP 18 850 E
-21-21
22
TP Solid series
With the temperature calibrators in the TP Solid series, the emphasis is on flexibility. Operation is easy, intuitive and allows fast access to comprehensive functions. In addition to dry block calibrators, micro calibration baths are also available to complete theportfolio. These baths are used as liquid bath calibrators with a magnetic stirrer that is controlled by rotary speed.
Reversible functions combined with an external reference sensor make it possible to test different temperature monitoring equipment without regard to shape, size or measurement method. A changeover switch allows users to change easily between the internal and external reference. All instruments in this series are equipped with a serial PC port.
Infrared calibration sleeve
22
23
Micro bath function
The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.
Black body function
A patented infrared calibration sleeve is used to calibrate IR pyrometers or thermal imaging cameras. The special surface structure and the asymmetrical shapes create a „cavity radiator“ with an emission factor of 0.9994, prevent the reflection of interference radiation and emit the required temperature in an ideal form. The pyrometer is simply held at the specified distance above the measurement opening, thereby forming the desired measurement area on the bottom for the calibration to be performed. A support base can be fitted directly on the unit.
Surface temperature function
Surface temperature sensors are calibrated using special sleeves that are fitted vertically with the required contact force. Switching calibration control to the external reference sensor creates the best possible temperature reference point on the surface of the sleeve. The reference sensor is located directly beneath the abutting face of the sleeve. The sleeve is designed in such a way that the best temperature homogeneity is achieved in the centre of the abutting face. The special design of the abutting face enables good thermal contact. There is no need to use a thermally conductive paste or other thermal conduction aids.
Calibration function for every need
Oberflächen-Kalibrierhülse
24
Technical data
Type TP 17 200 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-55...200 °C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -60...200 °C
Resolution 0.01 °C in the range of -9.99...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 12.5 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 600 VA
Type TP 17 200 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP 17 200 S
The TP 17 200 S temperature calibrator, which is also known as TP COOL, works in a temperature range from -55 to 200 °C.
25
Technical data
Type TP 17 165 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0.01 °C in the range of -9.99...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
TP 17 165 S
Type TP 17 165 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
26
Technical data
Type TP 17 166 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0.01 °C in the range of -9.99...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Type TP 17 166 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• Infrared calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
The TP 17 166 S temperature calibrator model has a very large calibration volume.
TP 17 166 S
27
Technical data
Type TP 17 166 S-U
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
-25...150 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0.01 °C in the range of -9.99...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Type TP 17 166 S-U
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• External calibration reference sensor TF 255-3-300
Optional accessories
• Transport case
• Adapter sleeve
• Infrared calibration sleeve
• Surface calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP 17 166 S-U
28
Technical data
Type TP M 165 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.1 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.3 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 170 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0.01 °C in the range of -9.99...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 12.5 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Type TP M 165 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
Optional accessories
• Transport case
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP M 165 S
29
Type TP M 165 S-UTechnical data
Type TP M 165 S-U
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.1 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.3 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
-25...150 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 170 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range -50...165 °C
Resolution 0.01 °C in the range of -9.99...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 12.5 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
• External calibration reference sensor TF 255-3-300
Optional accessories
• Transport case
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• Surface calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP M 165 S-U
30
Technical data
Type TP M 225 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
RT...225 °C±0.2 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...225 °C±0.4 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
RT...225 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 170 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...225 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
Type TP M 225 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
Optional accessories
• Transport case
• Servive transport bag
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP M 225 S
31
Technical data
Type TP M 225 S-U
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
RT...225 °C±0.2 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...225 °C±0.4 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
RT...225 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
RT...200 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 170 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...225 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
TP M 225 S-U
Type TP M 225 S-U
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
• External calibration reference sensor TF 255-3-300
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• Surface calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
32
Technical data
Type TP M 255 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
RT...255 °C±0.2 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...255 °C±0.4 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
RT...255 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 170 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...225 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
TP M 255 S
Type TP M 255 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
33
Technical data
Type TP M 255 S-U
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
RT...255 °C±0.2 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...255 °C±0.4 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
RT...255 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
RT...200 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 170 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...225 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
TP M 255 S-U
Type TP M 255 S-U
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
• External calibration reference sensor TF 255-3-300
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• Surface calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
34
Technical data
Type TP 17 450 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...450 °C±0.3 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
RT...450 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 60 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...450 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 2000 VA
TP 17 450 S
Type TP 17 450 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• Infrared calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
The TP 17 450 S temperature calibrator model has a very large calibration volume.
35
Type TP 17 450 S-UTechnical data
Type TP 17 450 S-U
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...450 °C±0.3 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
RT...450 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
RT...400 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...450 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 2000 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
• External calibration reference sensor TF 650-3-300
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• Infrared calibration sleeve
• Surface calibration sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP 17 450 S-U
36
TP 17 650 S
Technical data
Type TP 17 650 S
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...650 °C±0.4 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display 2-line, 4-digit displayRed / green, unit °C (°F optional)
Display range 0...650 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
150 mm330 + 70 mm270 mm
Weight Approx. 7.5 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
Type TP 17 650 S
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Service transport bag
• Adapter sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
37
Technical data
Type TP 28 850 E
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...850 °C±0.5 °C±0.05 °C60...100 mm oder 160...200 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 18 o. 28 mm / depth 100 o. 200 mm
Display
Display 2-line, 16-digit displayUnit °C (°F optional)
Display range 0...850 °C
Resolution 0.01 °C in the range of RT...99.99 °C, else 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
410 mm290 mm415 + 100 mm
Weight Approx. 16 kg
Power supply 230 VAC, 50 / 60 Hz
Power consumption Approx. 2000 VA
TP 28 850 E
Type TP 28 850 E
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
38
Type TP 17 ZEROTechnical data
Type TP 17 ZERO
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-10...100 °C±0.05 °C at 0 °C±0.05 °C at 0 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
7 drillings with Ø 6,5 mm, depth 150 mm
Display
Display 1-line, 4-digit displayRed, unit °C (°F optional)
Display range -10...100 °C
Resolution 0.1 °C
General data
DimensionsJ WidthJ HeightJ Depth
160 mm320 + 50 mm230 mm
Weight Approx. 7 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Operating manual
Optional accessories
• Transport case
• PC software
• PC cable
• DKD certificate
• Works certificate
TP 17 ZERO
The TP 17 ZERO temperature calibrator is ideal for creating the ice point.
-39-39
40
TP Premium series
The TP Premium series stands for optimum performance and outstanding ease of use. With the help of the self-explanatory menu structure, all the necessary entries can be made quickly and easily. The block and set temperature, as well as the difference and the variance of the stability, are displayed on the touch display. The block temperature can be set to precisely 0.001 °C.
Micro bath function
The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.
Dry block function
The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.
41
Black body function
A patented infrared calibration sleeve is used to calibrate IR pyrometers or thermal imaging cameras. The special surface structure and the asymmetrical shapes create a „cavity radiator“ with an emission factor of 0.9994, prevent the reflection of interference radiation and emit the required temperature in an ideal form. The pyrometer is simply held at the specified distance above the measurement opening, thereby forming the desired measurement area on the bottom for the calibration to be performed. A support base can be fitted directly on the unit.
Surface temperature function
Surface temperature sensors are calibrated using special sleeves that are fitted vertically with the required contact force. Switching calibration control to the external reference sensor creates the best possible temperature reference point on the surface of the sleeve. The reference sensor is located directly beneath the abutting face of the sleeve. The sleeve is designed in such a way that the best temperature homogeneity is achieved in the centre of the abutting face. The special design of the abutting face enables good thermal contact. There is no need to use a thermally conductive paste or other thermal conduction aids.
41
42
Type TP 38 165 E Technical data
Type TP 38 165 E
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.1 °C0.01...0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display Monochrome, graphic displayUnits °C / °F / K
Display range -50...165 °C
Resolution 0.01 °C
General data
DimensionsJ WidthJ HeightJ Depth
153 mm347 mm348 mm
Weight Approx. 12 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• Precision measuring instrument
• DKD certificate
• Works certificate
TP 38 165 E
43
Technical data
Type TP 38 165
Control sensor switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.1 °C0.01...0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display Monochrome, graphic displayUnits °C / °F / K / Ω / mV / mA
Display range -50...165 °C
Resolution 0.01 °C
General data
DimensionsJ WidthJ HeightJ Depth
153 mm347 mm348 mm
Weight Approx. 12 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
TP 38 165
Type TP 38 165
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• External calibration reference sensor
• DKD certificate
• Works certificate
44
Technical data
Type TP 38 650 E
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...650 °C±0.2 °C0.03...0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display Monochrome, graphic displayUnits °C / °F / K
Display range 0...650 °C
Resolution 0.01 °C
General data
DimensionsJ WidthJ HeightJ Depth
153 mm347 mm348 mm
Weight Approx. 10 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz, optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
TP 38 650 E
Type TP 38 650 E
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• Precision measuring instrument
• DKD certificate
• Works certificate
45
Type TP 38 650 Technical data
Type TP 38 650
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
RT...650 °C±0.2 °C0.03...0.1 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display Monochrome, graphic displayUnits °C / °F / K / Ω / mV / mA
Display range 0...650 °C
Resolution 0.01 °C
General data
DimensionsJ WidthJ HeightJ Depth
153 mm347 mm348 mm
Weight Approx. 10 kg
Power supply 230 VAC, ±10 %, 50 / 60 Hz,optional 115 VAC, ±10 %, 50 / 60 Hz
Power consumption Approx. 1000 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• External calibration reference sensor
• DKD certificate
• Works certificate
TP 38 650
46
Type TP 37 200 E
TP 37 200 E
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• PC- and network cable
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• External reference sensor TF 255-3-300
• PC software
• Network-switch, barcode-reader, WLAN-router
• DKD certificate
• Works certificate
Technical data
Type TP 37 200 E
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-55...200 °C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display Brilliant Color-Touchscreen (7“)Viewing angle 120...140°Brightness 400 cd / m²Unit °C / °F
Display range -60...200 °C
Resolution 0.1 / 0.01 / 0.001 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 12.5 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 600 VA
47
TP 37 165 E
Type TP 37 165 E
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• PC- and network cable
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• External reference sensor TF 255-3-300
• PC software
• Network-switch, barcode-reader, WLAN-router
• DKD certificate
• Works certificate
Technical data
Type TP 37 165 E
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165°C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 150 mm
Display
Display Brilliant Color-Touchscreen (7“)Viewing angle 120...140°Brightness 400 cd / m²Unit °C / °F
Display range -50...165 °C
Resolution 0.1 / 0.01 / 0.001 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 10 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
48
Typ TP 37 166 E
TP 37 166 E
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• PC- and network cable
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• Infrared calibration sleeve
• Surface calibration sleeve
• External reference sensor TF 255-3-300
• PC software
• Network-switch, barcode-reader, WLAN-router
• DKD certificate
• Works certificate
Technical data
Type TP 37 166 E
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.2 °C±0.05 °C110...150 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
-25...150 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 150 mm
Display
Display Brilliant Color-Touchscreen (7“)Viewing angle 120...140°Brightness 400 cd / m²Unit °C / °F
Display range -50...165 °C
Resolution 0.1 / 0.01 / 0.001 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 13 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
The Typ TP 37 166 E temperature calibrator model has a very large calibration volume.
49
Type TP 3M 165 E
TP 3M 165 E
Technical data
Type TP 3M 165 E
Control sensor Switchable internal / external
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.1 °C ±0.05 °C110...150 mm
Dry block
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.3 °C±0.05 °C123...163 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
-35...165 °C±0.5 °C±0.05 °C110 mm
Surface
Temperature rangeToleranceStabilityMeasurement zone
-25...150 °C±1 °C±0.2 °C
Block
Ø 60 mm / depth 170 mm
Display
Display Brilliant Color-Touchscreen (7“)Viewing angle 120...140°Brightness 400 cd / m²Unit °C / °F
Display range -50...165 °C
Resolution 0.1 / 0.01 / 0.001 °C
General data
DimensionsJ WidthJ HeightJ Depth
210 mm380 + 50 mm300 mm
Weight Approx. 13 kg
Power supply 100...240 VAC, 50 / 60 Hz
Power consumption Approx. 400 VA
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• PC- and network cable
• Operating manual
• Sensor basket, suction pump, transport cover
• Magnetic stirrer with magnet lifter
• Sensor lid with 5 silicone plugs
Optional accessories
• Transport case
• Adapter sleeve
• Tube insert
• Infrared calibration sleeve
• Surface calibration sleeve
• External reference sensor TF 255-3-300
• PC software
• Network-switch, barcode-reader, WLAN-router
• DKD certificate
• Works certificate
50
Technical data
Type TP 28 1300
Control sensor Internal
Micro Bath
Temperature rangeToleranceStabilityMeasurement zone
Dry block
Temperature rangeToleranceStabilityMeasurement zone
400...1300 °C±2 °C±0.5 °Cat 200 mm
Infrared
Temperature rangeToleranceStabilityMeasurement zone
Surface
Temperature rangeToleranceStabilityMeasurement zone
Block
Ø 28 mm / depth 200 mm
Display
Display 1-line, 4½-digit displayRed, unit °C (°F optional)
Display range 0...1300 °C
Resolution 0.5 °C
General data
DimensionsJ WidthJ HeightJ Depth
510 mm290 mm415 + 100 mm
Weight Approx. 25 kg
Power supply 230 VAC, 50 / 60 Hz
Power consumption Approx. 1000 VA
Type TP 28 1300
Scope of delivery
• Test certificate
• Mains cable
• Insert exchange tool
• Operating manual
Optional accessories
• Transport case
• Adapter sleeve
• PC software
• PC cable
• DKD certificate
• Works certificate
TP 28 1300
-51-51
52
Overview temperature calibrators
TP Basic TP Solid
-55…200 °C TP 17 200 TP 17 200 S
-35…165 °C TP 17165 M TP 17 165 TP 17 166 TP 17 165 S TP 17 166 S
-10...100 °C TP 17 Zero
RT…200 °C TP 18 200 E
RT…225 °C
RT…255 °C
RT…450 °C TP 17 450 TP 17 450 S
RT…650 °C TP 17 650 M TP 17650 TP 17 650 S
RT…850 °C TP 18 850 E TP 28 850 E
400…1300 °C
Metrology*
Best Resolution 1 °C 1 °C 0.1 °C 0.1 °C 0.01 °C 0.01 °C 0.01 °C
Stability 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.05 °C 0.05 °C 0.05 °C
Tolerance 1 °C 1 °C < 0.8 °C < 0.6 °C < 0.4 °C < 0.5 °C < 0.3 °C
Testholder
Block Ø 18 / 28 mm 28 mm 28 mm 60 mm 6.5 / 28 mm 18 / 28 mm 60 mm
Dry block ü ü ü ü ü ü ü
Infrared ü
Microbath
Surface
Scope of delivery
PC connection ü ü ü
External reference connection
Internal precision measuring instrument
Data logger function
Controller OFF ü ü ü ü
Manual control ü ü ü ü
Set-value memory ü ü
Temperature levels ü ü
Gradient control ü ü
Periodic counter ü ü ü ü ü ü
Optional accessories
Transport case ü ü ü ü ü ü ü
Service transport bag** ü ü ü ü ü
PC software ü ü ü
PC cable ü ü ü
Precision measuring instrument
External calibration reference sensor
* The specifications listed are for guidance. Detailled information can be found on the individual product pages.** For calibrators with slim body only
53
TP Premium
TP 37 200 E
TP M 165 S TP 17 166 S-U TP M 165 S-U TP 38 165 E TP 38 165 TP 37165 E TP 37 166 E TP 3M 165 E
TP M 225 S TP M 225 S-U
TP M 255 S
TP 17 450 S-U
TP 38 650 E TP 38 650
TP 28 1300
0.01 °C 0.01 °C 0.01 °C 0.01 °C 0.5 °C 0.01 °C 0.001 °C 0.001 °C 0.001 °C
0.05 °C 0.05 °C 0.05 °C ~0.03 °C 0.5 °C ~0.03 °C 0.05 °C 0.05 °C 0.05 °C
< 0.2 °C < 0.3 °C < 0.2 °C < 0.2 °C 2 °C < 0.2 °C < 0.2 °C < 0.3 °C < 0.2 °C
60 mm 60 mm 60 mm 28 mm 28 mm 28 mm 60 mm 60 mm 60 mm
ü ü ü ü ü ü ü ü ü
ü ü ü ü ü ü
ü ü ü
ü ü ü ü ü
ü ü ü ü ü ü ü ü ü
ü ü ü ü ü ü
Internal precision measuring instrument
ü ü
ü ü ü ü
ü ü ü ü ü ü ü ü
ü ü ü ü ü ü
ü ü ü ü ü ü ü ü
ü ü ü ü ü ü ü ü
ü ü ü ü ü ü ü ü
ü ü ü ü ü ü ü ü
ü ü ü ü ü ü ü ü ü
ü ü ü
ü ü ü ü ü ü ü ü ü
ü ü ü ü ü ü ü ü ü
Precision measuring instrument
ü
External calibration reference sensor
ü ü ü ü
54
Accessories
Adapter sleevesDry-block calibrators are designed to simplify temperature calibration in the lab and in the field. With the help of adapter sleeves, straight temperature sensors with almost any length and diameter can be calibrated. The dry block covers the entire temperature range of the calibrator with no need for changing the calibration medium. Viscosity, flash point and outgassing are of no concern. Every adapter sleeve can be equiped with a single or several multi bores. Bores with diameters ranging from 1.5 to 25.5 mm can be realised in 0.5 mm steps. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item.
Calibration liquidsUsing a liquid calibration medium is advantageous for checking temperature sensors with unusual shapes or dimensions. The test item is immersed in the liquid without an insulating air gap, resulting in direct contact between the calibrator and the test item. The calibration liquid is chosen according to the desired calibration temperature. The sensor lid with 5 silicone plugs and / or a support base ensures the stable positioning of the test items in the calibration bath. The lid reduces heat emission over the surface of the liquid, thereby ensuring optimum measurement results.
Tub insertOur tub insert is the ideal solution for applications in which a variety of liquids are used. It eliminates the time-consuming task of exchanging the liquids and cleaning the bath. The separate tub insert is just as leak-proof as the bath itself.
Demineralised water Silicone oil 10 CS Silicone oil 20 CS Silicone oil 50 CS
Limits 2...95 °C -35...155 °C 7...220 °C 50...270 °C
Flash point 165 °C 230 °C 280 °C
Calibration and testing softwareThe in-house calibration software application is used for temperature calibrators that are equipped with an external interface for programming and evaluating the calibration values. It can be operated easily from an external PC. The following calibration tasks can be performed:
• Programmable ramp functions
• Programmable temperature cycles
• Series tests (e.g. for incoming goods inspection)
• Preparing the test data in graphical and in tabular form
• Incorporating customer data in the certificates
• Programmable temperature gradients
55
Checking groups of temperature sensors can be automated by extending your SIKA calibrator with a TT-Scan unit and calibration software. Up to eight test items can be checked at the same time with this arrangement. The configuration of the test item type is free programmable. A reference sensor can be connected. The TT-Scan unit has a USB port for connection to a PC. SIKA calibration software analyses the measurement data and presents the results in graphic or tabular form. At the same time it automatically generates up to 8 certificates, which may also include customer data.
Resistance thermometers, thermocouples, temperature transmitters and switches must be calibrated using an instrument that measures the output signal and displays it as a temperature.
For your test equipment monitoring
TT-Scan
55
56
Properties
Possibilities to connect
Version Scanner device with precision measuring instrument
Measuring inputs SwitchableFor up to 8 sensorsSensor type free confi gurable
General data
Power supply 230 VAC ±10 %, 50 / 60 Hz over adapter
Power consumption Approx. 100 W
Dimensions (D x W x H) 200 x 140 + 40 x 380 mm
Weight Approx. 2.5 kg
Equipment features
32 x 4 mm connections free of thermal voltageConnection for external calibration reference sensorExternal cold junction availableSerial USB data interface, incl. USB data cable
Options
Aluminium transport case, test & calibration software, DKD certificate,SIKA works certificate, external calibration reference sensors
TT-Scan
Type TT-Scan
1
2
3
4
2
3
4
2
3
2
3
2
3
2
3
Wire Wire Wire
Switch
57
Version Measuring range Tolerance
Resistance thermometer EN 60751
Pt100 Pt500 Pt1000
2-, 3-, 4-wire -90.00 °C...850.00 °C ±0.005 % full scale ±0.01 °C
Connection possibility through 4 mm connections free of thermal voltage
Thermocouples according to DIN EN 60584 / DIN 43710
Type K NiCr-NiAl -90.00...999.99 °C 1000.0...1370.0 °C
±0,007 % full scale ±0.01 °C ±0,005 % full scale ±0.1 °C
Type J FeCu-Ni -90.00...900.00 °C ±0,005 % full scale ±0.01 °C
Type N NiCrSi - NiSiMg -90.00...999.99 °C 1000.0...1370,0 °C
±0,007 % full scale ±0.01 °C ±0,005 % full scale ±0.1 °C
Type E NiCr-CuNi -90,00...700.00 °C ±0,005 % full scale ±0.01 °C
Type R Pt13Rh – Pt 0.00...999.99 °C 1000.0...1760.0 °C
±0,05 % full scale ±0.01 °C ±0,03 % full scale ±0.1 °C
Type T Cu-CuNi -90.00...400.00 °C ±0,01 % full scale ±0.01 °C
Type B Pt30Rh-Pt6Rh 0.00...999.99 °C 1000.0...1820.0 °C
±0,05 % full scale ±0.01 °C ±0,03 % full scale ±0.1 °C
Type S Pt10Rh-Pt 0.00...999.99 °C 1000.0...1760.0 °C
±0,05 % full scale ±0.01 °C ±0,03 % full scale ±0.1 °C
Type L Fe-CuNi -90.00...900.00 °C ±0,005 % full scale ±0.01 °C
Type U Cu-CuNi 90.00...600.00 °C ±0,01 % full scale ±0.01 °C
Automatic comparison point compensation between 0 °C and 60 °CAccuracy of the comparison point Pt100 DIN class APossibility of connection through 4 mm connections free of thermal voltage
Standard signal input
Current (switchable) mA 0(4)...20 mA ±0.015 % full scale ±0.01 mA
Transmitter supply 24 VDC, Imax = 30 mA, Possibility of connection through 4 mm connections free of thermal voltage
Temperature switch
Automatic detection of an edge change, determining the hysteresis,Independent detection normally closed / normally openPotential-free input contacts (Umax = 5 V, Imax = 1 mA) Possibility of connection through 4 mm connections free of thermal voltage
Calibration reference sensor connection
Pt100 4-wire -90.00...850.00 °C ±0.005 % full scale ±0.01 °C
Polynomial correctable through internal parameters or through external EEPROM inside the sensorPossibility of connection through 7-pin built-in socket
Measuring inputs
58
If the sensor to be calibrated is too short to be inserted into the homogeneous temperature zone of the metal block, an external reference sensor can be used without any problems. This results in a small, flexible measurement zone.
Calibration reference sensor - Type TF
Pt100 without probe specific linearization in the controller for Series TP...S-U, TP 3...
Technical dataMeasuring rangeTF 255-3-300 -50...255 °C / sensitive area 2 mmTF 650-3-300 -50...650 °C / sensitive area 5 mmTolerance±0.05 °C in the range of -9.99...99.99 °C, else ±0.1 °CVersionMaterial Rust and acid-proof
Stainless steel 1.4571
Robust plastic handle
Immersion tube Ø 3 mm, L = 300 mm
Electricalconnection
Silicon cable with 4-pin mini DIN-plug
Calibration reference sensor - Type TFEE
Pt100 with probe specific linearization through EEPROM in the handle for TT-Scan and Series TP 38...
Technical dataMeasuring rangeTFEE 255-3-300 -50...255 °C / sensitive area 2 mm
TFEE 650-3-300 -50...650 °C / sensitive area 5 mm
Tolerance±0.05 °C in the range of -35.00...199.99 °C, else ±0.1 °CVersionMaterial Rust and acid-proof
Stainless steel 1.4571
Robust plastic handle
Immersion tube Ø 3 mm, L = 300 mm
Electricalconnection
Silicon cable with 7-pin mini DIN-plug
Type TF 650-3-300 An ace of calibration
Particular attention is given to the physical construction to ensure that shocks have minimal effect on the reference sensor.
The use of robust measuring elements in thinfilm technology ensure standardised and reliable performance.
Intensive ageing tests are carried out at the maximum operating temperature to examine longterm temperature stability. In order to detect longterm effects through thermal stress, a defined tempering process is carried out with a special selection of reference sensors over 300 hours. In the case of stress caused by thermocycling, no significant hysteresis effects were found.
The physical structure of the reference sensors requires that different materials be joined together. The special design of the joint areas prevents the occurrence of parasitic thermoelectric voltages. Thus the measurement reading is not affected by the temperature gradients from the measurement point to the handle.
In examining the self-heating characteristics it was seen that measurement currents ≤ 1 mA are ideally suited, since no distortion of the measurement result occurs. Here the self-heating effect can be neglected.
Calibration reference sensors
-59-59
60
61
PRESSURE CALIBRATORS
J Pneumatic pressure pumps
J Hydraulic pressure pumps
J Hydraulic pressure generators
J Digital pressure gauges
J Pressure calibrators
DS_Pressure_calibrators 05/2014
Including products with:
62
Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important.
However, the characteristics of the even best sensor or transducer can be altered by a wide variety of factors. This drift cannot be prevented, and it leads to incorrect readings.
Calibration allows these deviations to be measured and documented in a certificate. All pressure measuring devices that significantly affect processes or activities should be calibrated before being used.
Good reasons for proper and reliable calibration:
• Maintaining consistently high product quality
• Fulfilling industrial requirements
• Fulfilling quality assurance requirements
• Process optimisation
• Increasing productivity
• Avoiding unexpected production downtimes
• Employee and customer safety
• Environmental requirements / ecological aspects
• Profit optimisation / economic aspects
SIKA‘s mobile test and calibration devices are effective aids for performing the necessary test and calibration tasks quickly.
Requirements for pressure sources
The essential requirements for manual pressure generation are:
• Easy connection to test samples
• Simple and easy pressure generation
• Maintenance free operation
These aspects have been taken into account and implemented in the design of our test pumps and pressure generators.
Test pumps or pressure generators
SIKA portable pressure generators are the first choice for stationary use. Unlike complicated and sensitive plate scales, there is no need to take gravity into account or perform complicated alignment, since measurements are based on direct comparison. Another advantage of pressure generators is one-hand operation, which makes repetitive test runs more ergonomic.
Pressure sources
Handling
Test sample
Digital pressure gauge(Reference)
Easy pressure generation
Manual pressure pumps
Mobile and simple
63
3 in 1
Full version / P1000.1
Hydraulic or pneumatic
Air, water and oil are used as pressure media. Especially in application areas in which wetting of the test sample is not allowed or the use of aggressive or ionising substances must be avoided, air is the ideal test medium.
SIKA‘s pneumatic test pump fulfils requirements that in many cases can only be covered by several pumps from other suppliers.
Manual pressure generation in the medium pressure range up to 60 bar using a handle is unique – no other pump can do this.
Integrated negative pressure capability enables operating with vacuum down to -950 mbar. A changeover valve enables switching from positive pressure to negative pressure with no need for special tools.
A large-volume pressure regulator with ultrafine thread pitch is used for precise pressure adjustment in the low mbar range, enabling accurate settings in the low pressure region.
The easily operated hydraulic test pumps and pressure generators are specifically designed for the medium to high pressure range. They have a built-in reservoir for the hydraulic fluid. Pressures up to 350 bar, 700 bar or 1000 bar can be generated, depending on the model.
Standard adapter kit
G⅛ G¼ G⅜ G½ ⅛ NPT ¼ NPT ½ NPT M12 x 1.5 M20 x 1.5 G⅛ A G¼ A
OEM version and full version
Depending on the model a matching pressure hose is part of the basic configuration of the OEM version of the test pump. The hydraulic hoses are fitted with a self-sealing quick coupling.
Inch, conical or metric adapters for all commonly used connection threads are available in the full version. A matching seal kit is also included with the pump. All of the equipment is held in a carrying case with a foam-rubber insert.
A single pump for a variety of requirements
Adapter kits
64
Type P 4
OEM version
Pressure medium Air
Dimensions Approx. 225 x Ø 55 mm
Weight Approx. 980 g
Pressure ranges
Negative pressure -0.3 bar (depending on test sample / reference)
Positive pressure 4 bar
Connections
Reference G¼ with Quick-Snap Y-plug-connection with PA hose (2 x 1m)
Test sample G¼ with quick coupling and pressure hose (1m)
Full version
Adapter kit Chrome-plated brass
Gasket kit Teflon® Seals and O-rings
Dimensions Approx. 450 x 370 x 110 mm
Weight Approx. 4.2 kg
Type P 4
Pneumatic pressure pumps
65
Types P 40.2 and P 60
Type P 40.2 P 60
OEM version
Pressure medium Air
Dimensions Approx. 240 x 170 x 50 mm
Weight Approx. 1.1 kg
Pressure ranges
Negative pressure -0.95 bar -0.95 bar
Positive pressure 40 bar 60 bar
Connections
Reference G¼
Test sample G¼ with quick coupling and pressure hose (1m)
Full version
Adapter kit Chrome-plated brass
Gasket kit Teflon® Seals and O-rings
Dimensions Approx. 450 x 370 x 110 mm
Weight Approx. 4.2 kg
66
Type P 350.1
OEM version
Pressure medium Distilled water or hydraulic fluid
Dimensions Approx. 240 x 170 x 50 mm
Weight Approx. 1.1 kg
Pressure ranges
With destilled water 0...350 bar
With hydraulic fluid 0...350 bar
Connections
Reference G½
Test sample G¼ with quick coupling and pressure hose (1m)
Full version
Adapter kit Chrome-plated brass
Gasket kit Teflon® Seals and O-rings
Dimensions Approx. 450 x 370 x 110 mm
Weight Approx. 3.5 kg
Type P 350.1
Hydraulic pressure pumps
67
Type P 700.2
OEM version
Pressure medium Distilled water or hydraulic fluid
Dimensions Approx. 255 x 225 x 85 mm
Weight Approx. 1.7 kg
Pressure ranges
With destilled water 0...700 bar
With hydraulic fluid 0...700 bar
Connections
Reference G¼
Test sample G¼ with quick coupling and pressure hose (1m)
Full version
Adapter kit Stainless steel
Gasket kit Teflon® Seals and O-rings
Dimensions Approx. 450 x 370 x 125 mm
Weight Aapprox. 4.8 kg
Type P 700.2
68
Type P 700.2 - 1000
Type P 700.2 - 1000
OEM version
Pressure medium Distilled water or hydraulic fluid
Dimensions Approx. 255 x 225 x 85 mm
Weight Approx. 1.9 kg
Pressure ranges
With destilled water 0...700 bar, test pressure 1000 bar
With hydraulic fluid 0...700 bar, test pressure 1000 bar
Connections
Reference G¼
Test sample G¼ with quick coupling and high pressure hose (1 m), 1000 bar
Full version
Adapter kit Stainless steel
Gasket kit Teflon® Seals and O-rings
Dimensions Approx. 450 x 370 x 125 mm
Weight Aapprox. 5 kg
69
Type P 700.G
OEM version
Pressure medium Hydraulic fluid
Dimensions Approx. 230 x 180 x 40 mm
Weight Approx. 6.6 kg
Pressure ranges
Distilled water
Hydraulic fluid 0...700 bar
Connections
Reference G½
Test sample G½
Full version
Test sample G¼ with quick coupling and pressure hose (1m)
Adapter kit Stainless steel
Gasket kit Teflon® Seals and O-rings
Dimensions Approx. 450 x 370 x 125 mm
Weight Approx. 9.3 kg
Type P 700.G
Hydraulic pressure generator
70
Practical
The test pumps and pressure generators are designed to enable the direct connection of all pressure systems to be tested using adapters. The test sample is easily connected using the rugged industrial hose with integrated quick coupling and supplied adapters. The reference is fitted directly at the top of the pump using a positioning adapter.
The required test pressure is initially generated using the handles and then adjusted precisely with the fine adjustment valve. As a result, the pressure on both instruments is the same.
The pressure relief valve allows continuous pressure reduction and ensures accurate and easy testing, even with decreasing pressure.
In the simplest case, the pressure is indicated by an analogue pressure gauge. An easy to read digital pressure gauge or hand-held instrument can also be used. The accuracy or adjustment of the pressure measuring device being tested can be checked by comparing the indicated reference value with the measured value for the device under test.
Practice orientated
Mobile and independent
SIKA test pumps and pressure generators are ideal for mobile use. Their low weight and compact design make them easy to transport directly to the measurement site. The instruments can be used immediately and do not require an additional power supply. There is no need to take along nitrogen bottles or connect the equipment to a compressed air network. Wear-free manual pressure generation is simple and easy, regardless of ambient temperature and orientation.
Possible areas of applicationSIKA test pumps and pressure generators can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. They cover a broad spectrum of industries with diverse applications.
• Assembly and commissioning
• Manufacturing and production
• Maintenance and service
• Quality assurance and test equipment monitoring
• RepairSIKA test pumps and pressure generators are suitable for testing, adjusting and calibrating pressure sensors, pressure gauges, pressure switches, safety valves and all types of pressure devices. They are optimised in their function and use and assist in the performance of specific tests and inspections.
Reference connection
Fine adjustment
Test connection
Force applied by pressing the handles together
Practical and independent
Mobile use
Discharge
71
Digital pressure gauges are particularly suitable for both stationary and mobile measurement and display of pressure. They can be used as reference pressure gauges to simplify the checking, adjustment and calibration of other pressure measurement devices directly on site.High accuracy in signal acquisition is achieved by using high-performance measuring cells with electronic linearisation of the characteristic curve. Suitable instruments are available for a wide variety of measurement tasks.Ease of use is assured by innovative design and advanced technology. All essential functions for everyday use can be selected conveniently at the press of a button. Excellent protection against dust and moisture is provided by a membrane keypad or rubber buttons.Integrated supplementary functions make our digital pressure gauges true all-rounders.
Advantages at a glance
• Exact and reliable measurement
• High operational readiness
• Easy and clear readout
• Well suited to difficult on-site tasks
• Easy to assemble and use
• Supplementary functions for extra value
• EX-version availiabe on request
Negative / Positive / and Differential Pressure
Measuring ranges from -1 bar negative pressure to 2500 bar positive pressure with high overpressure protection are available. Very small differential pressures in the millibar range can also be measured. Differential pressure measuring cells or two independent measuring inputs are used for this purpose.
Resolution / Accuracy
It is often necessary to use several mechanical pressure gauges when measurements must be made over a wide pressure range with sufficient accuracy. Digital pressure gauges with high resolution and precision can handle this task with just one instrument.An indicating accuracy of 0.5% to 0.01% covers the entire spectrum of requirements. This precision is often found only in sensitive laboratory instruments, whereas SIKA digital pressure gauges are designed for use in harsh industrial environments.
Tare / Zero
User-defined zero point setting at the push of a button makes offset adjustment easy and eliminates the need for tedious mechanical adjustment. Single-point adjustment allows the linear characteristic curve to be shifted in positive or negative direction over the entire measuring range.
Linearisation
Multi-point adjustment can be performed if it is necessary to adjust the indicated values at different test points. Two-point adjustment is available for setting the zero point and slope of the measuring cell curve. Some digital pressure gauges allow up to six offset values to be programmed in order to shift the characteristic curve to meet the most stringent customer expectations.
Battery operation / Auto-Off
Power is supplied by long-life batteries (ordinary or rechargeable). An external AC adapter can also be used. To increase battery operating time, a programmable Auto-Off function switches off the power to the instrument after prolonged inactivity. The electronics are designed for extremely low power consumption, which enables a battery life of significantly more than 1000 hours.
Digital pressure gauges
Exact and reliable
Type E2 / D2 and P
72
Display
The large illuminated digital local display shows the measured pressure and indicates the current status of the digital pressure gauge, even under poor lighting conditions. This eliminates the difficult task of reading a dial gauge and avoiding parallax errors. Needle jitter due to vibration or pressure fluctuations is eliminated. Display damping or averaging can be configured directly using display filters. This ensures easy, tireless readout.
Selectable pressure units
Another feature is the large selection of pressure units. Up to 13 different units are possible – far more than any complicated dual-scale or multi-scale gauge can offer.
The required display unit is selected directly on the digital pressure gauge and is clearly indicated on the display. No conversion necessary; the desired value can be read directly.
Area of application
The right measuring system is available for every measuring task. For simple applications with air or non-corrosive and non-ionising substances, low-cost unenclosed pressure sensors are used. In difficult applications with water or other aggressive media, high-quality stainless steel versions are used.
Once the intended use has been determined and the pressure range has been specified, a digital pressure gauge with an internal measuring cell is preferably used. For frequently changing application conditions, plug-in pressure sensors for various pressure ranges and applications can be fitted using adapters. Automatic sensor recognition using standard DIN connectors offers a simple Plug-&-Play solution.
Electronics / Pressure measuring cell
The measuring cells and electronics used in the gauges are temperature compensated, so that the effect of temperature on the readings is negligible. Liquid entry into the measuring system is not necessary, which eliminates the risk of damage from media residues. Another unbeatable feature of the electronic measuring cells is their immunity to pressure surges.
Min / Max Displays and Peak function
Experience shows that excess pressure and pressure peaks significantly higher than normal operating pressure occur at some measuring points. Min / max displays and fast peak value measurement cycles in digital pressure gauges assist in system analysis and allow peak values to be determined. This allows incorrect readings and violations of range limits to be detected and helps avoid damage to pressure systems. Preventive service is often less expensive than repairing or replacing defective instruments.
Protection class
High IP protection classes are available to minimise dust and water sensitivity. Rugged, impact-resistant digital pressure gauges are fitted with rubber caps for protection during transport and field use.
Direct mounting, built-in version and hand-held instrument
The compact, handy design proves its worth in everyday use. It puts an end to large-diameter gauges with sizes up to 250 mm, as is common with precision pressure gauges. The small size simplifies direct mounting. If necessary, built-in versions are available for switchgear cabinet or control panel mounting. Hand-held digital pressure gauges are especially suitable for applications where short-term pressure measurements are desired instead of continuous measurement.
3 Designs
Easy on-site use
Stainless steel version
-73-73
74
Digital pressure gauge selection table
Direct-mounting display instruments
= optionally available
BASIC SOLIDE-Ex E2 D-Ex D2 R
Accuracy (full scale) 0.5 % 0.5 % 0.1 % 0.1 % 0.2 %
Pressure range
-1...3 bar -1...3 bar
-1...1 bar
-1...2,5 bar
-1...5 bar
-1...30 bar-1...40 bar
-1...60 bar
-1...30 bar
-1...60 bar
-1...40 bar
-1...60 bar
-1...10 bar
-1...20 bar
-1...40 bar
-1...60 bar
0...300 bar0...400 bar
0...700 bar
0...300 bar
0...700 bar
0...400 bar
0...700 bar
0...100 bar
0...250 bar0...350 bar
0...500 bar
0...700 bar0...1000 bar 0...1000 bar 0...1000 bar
0...1500 bar0...2000 bar
Multi-point adjustment
Interchangeable measuring cellPC connection Data memory
Analogue outputSecond measuring inputRelais outputBuilt-in versionEx version
Version free of oil and grease
7575
Hand-held instruments
PREMIUM BASIC SOLID BASIC SOLID PREMIUMP L MH 3161 MH 3181 MH 3111 MH 3151 MH 31560.5 %0.2 %0.05 %
0.05 %0.025 %0.01 %
0.2 % 0.2 % 0.2 % 0.2 % 0.2 %
-1...25 mbar
-10...350 mbar
-2...2.5 mbar-20...25 mbar0...100 mbar0...250 mbar-200...350 mbar0...400 mbar
-1...1 bar
-1...2,5 bar
-1...5 bar
-1...2 bar
0...1.3 bar
-100...2000 mbar
0...1 bar0...1.3 bar-1...1.5 bar-1...2 bar0...2.5 bar-1...3 bar0...4 bar
0...6 bar
-1...10 bar
-1...20 bar
-1...40 bar
-1...60 bar
-1...10 bar
-1...20 bar
0...7 bar-1...10 bar0...16 bar
0...25 bar0...40 bar
0...60 bar0...100 bar
0...250 bar0...350 bar
0...500 bar
0...700 bar
0...100 bar
0...200 bar
0...400 bar
0...700 bar
0...100 bar0...160 bar
0...250 bar
0...400 bar
0...600 bar
0...1000 bar0...1500 bar0...2000 bar0...2500 bar
0...1000 bar 0...1000 bar
76
Data memoryThe logger function for local data storage can be used to record pressure curves automatically and perform leak tests. The integrated data memory in digital pressure gauges allows a variety of data sets to be recorded directly. The time interval between samples is programmable and the maximum recording interval is configurable. The stored values can be displayed on a PC. Data import at the press of a button is also possible. In this case the data is shown directly on the display. In this process the values are automatically annotated with the date and time of day using an integrated real-time clock.
Type R
Analogue output
An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments.
Relay output / Alarm signalling
Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks. A built-in buzzer generates an alarm when the pressure exceeds the range of the programmed minimum and maximum pressure levels.
Temperature display
Temperature measurement is often required in addition to pressure measurement. For this purpose, a temperature sensor is integrated in the measuring cell to detect the temperature of the medium. The process temperature can be displayed at the press of a button. This allows two quantities to be measured at a single measuring point, which saves costs.
Explosion protection
Explosion-proof versions are also available for use in potentially explosive locations, e.g. oil refineries, chemical plants and drilling platforms.
Example applications
• Continuous or temporary checking of a wide variety of system pressures
• Air density measurement in building shells for the detection and elimination of problem areas and avoiding structural damage
• Monitoring the degree of soiling of filter units in ventilation or air conditioning systems
• Recording pressure drops for the determination of leakage rates in leak tests
• Measurement of barometric air pressure for the determination of weather conditions
• Reference pressure gauge for calibration tasks
Supplementary functions
77
Type ATechnical data
Accuracy (full scale) 0.6 %
Pressure ranges Resolution
-0.6...0 bar-1...0 bar-1...0.6 bar-1...1.5 bar-1...3 bar-1...5 bar-1...9 bar-1...15 bar-1...24 bar0...0.6 bar0...1 bar0...1.6 bar0...2.5 bar0...4 bar0...6 bar0...10 bar0...16 bar0...25 bar0...40 bar0...60 bar0...100 bar0...160 bar0...250 bar0...400 bar0...600 bar
5 mbar10 mbar 20 mbar20 mbar50 mbar50 mbar0.1 bar0.2 bar0.2 bar5 mbar10 mbar20 mbar20 mbar50 mbar50 mbar0.1 bar0.2 bar0.2 bar0.5 bar0.5 bar1 bar2 bar2 bar2 bar5 bar
Functions
Selectable UnitsPressure BarFeaturesMeasuring inputsRelay outputBuilt-in version
1 x directOptionalOptional
Display / RepresentationDisplayDamping
AnalogueOptional
Measuring rateStandard AnalogueProcess connectionConnection optionsMaterialOperating temperature
G¼1.45420...50 °C
HousingDegree of protectionDimensionsMaterialWeight
IP54 (front)Ø 100 mm T=50 mm H=120 mmStainless steel250 g
Analogue pressure gauges
77
78
Digital pressure gauges
Type E-Ex Type D-Ex
Technical data
Accuracy (full scale) 0.5 %
Pressure range Resolution
-1...30 bar0...300 bar
10 mbar100 mbar
Technical data
Accuracy (full scale) 0.1 %
Pressure range Resolution
-1...3 bar-1...30 bar-1...60 bar0...300 bar0...700 bar
1 mbar10 mbar10 mbar100 mbar200 mbar
79
Functions
Type E-Ex D-Ex
Adjustment options
LinearisationTare / Zero
Selectable units
PressureTemperature
bar bar, mbar, hPa, kPa, MPa, PSI, kp/cm²
Features
Measuring inputsPC connection Analogue outputRelay outputBuilt-in versionExplosion protectionVersion free of oil and grease (optional)
1 x direct
Ex II 1G EEx ia II C T5 / T6 (< 200 bar)
Data memory
Number of memorysRecording intervalRecording durationData sets
Display / Representation
Multi-functional LCDBargraphIlluminationDisplay filterMin / max value
4 digit
Measuring rate
StandardPeak / Fast
500 msec.
Process connection
Connection optionsMaterialMedium temperatureFor aggressive media
G¼ / H16 UNF1.0718 zinc-plated / 1.44350...50 °C
Housing
Degree of protectionDimensionMaterialOperating temperatureWeight
IP65 (front) / IP65Ø 70 mm T=30 mm H=100 mmABS plastic0...50 °C130 g
Power
Auto-off functionBattery typeExt. powerBattery operation
1 x 3V CR
1000 h
80
Technical data
Accuracy (full scale) E2 0.5 % D2 0.1 %
Pressure range Resolution
-1...3 bar-1...40 bar-1...60 bar0...400 bar0...700 bar0...1000 bar
1 mbar10 mbar10 mbar100 mbar100 mbar100 mbar
10 mbar10 mbar100 mbar100 mbar100 mbar
Technical data
Accuracy (full scale) 0.2 %
Pressure range Resolution
-1...1 bar-1...2.5 bar-1...5 bar-1...10 bar-1...20 bar-1...40 bar-1...60 bar0...100 bar0...250 bar0...350 bar0...500 bar0...700 bar0...1000 bar0...1500 bar0...2000 bar
1 mbar1 mbar1 mbar10 mbar10 mbar10 mbar10 mbar100 mbar100 mbar100 mbar100 mbar100 mbar1 bar1 bar1 bar
Type E2, D2 Type R
81
Functions
Type E2 / D2 R
Adjustment options
LinearisationTare / Zero
6 points
Selectable units
PressureTemperature
bar, mbar, kPa, MPa, PSI, kg/cm² bar°C
Features
Measuring inputsPC connection Analogue outputRelay outputBuilt-in versionExplosion protection
1 x direct 1 x directRS232 (optional)
Data memory
Number of memorysRecording intervalRecording durationData sets
60.000 values (auto)1 sec...10 h1 min...1000 hPressure / Temperature
Display / Representation
Multi-functional LCDBargraphIlluminationDisplay filterMin / max value
4 ½ digit
4 digit
Measuring rate
StandardPeak / Fast
10 msec.10 msec.
100 msec. 8 msec.
Process connection
Connection optionsMaterialMedium temperatureFor aggressive media
G¼1.4404-20...80 °C
G½1.4542-10...70 °C
Housing
Degree of protectionDimensionMaterialOperating temperatureWeight
IP67 (front) / IP67Ø 80 mm T=30 mm H=100 mmZinc casting0...50 °C540 g
IP65 (front) / IP40Ø 85 mm T=30 mm H=30 mmAluminium-10...70 °C450 g
Power
Auto-off functionBattery typeExt. powerBattery operation
2x 1.5 V AA
1500 h
2x 1.5 V AAA
8000 h
82
Type LType P
Technical data
Accuracy (full scale) 0.5 % 0.2 % 0.05 %
Pressure range Resolution
-1...1 bar-1...2.5 bar-1...5 bar-1...10 bar-1...20 bar-1...40 bar-1...60 bar0...100 bar0...250 bar0...350 bar0...500 bar0...700 bar0...1000 bar0...1500 bar0...2000 bar0...2500 bar
1 mbar1 mbar1 mbar10 mbar10 mbar10 mbar10 mbar100 mbar100 mbar100 mbar100 mbar100 mbar1 bar1 bar1 bar1 bar
1 mbar1 mbar1 mbar10 mbar10 mbar10 mbar10 mbar100 mbar100 mbar100 mbar100 mbar100 mbar1 bar1 bar1 bar1 bar
0.1 mbar0.5 mbar0.5 mbar1 mbar2 mbar5 mbar5 mbar10 mbar20 mbar50 mbar50 mbar50 mbar100 mbar200 mbar500 mbar
Technical data
Accuracy (full scale) 0.05 % 0.025 %* 0.01 %*
Pressure range Resolution
-1...2 bar-1...10 bar-1...20 bar0...200 bar0...400 bar0...700 bar0...1000 bar
0.1 mbar1 mbar1 mbar10 mbar50 mbar100 mbar100 mbar
1 mbar10 mbar50 mbar100 mbar100 mbar
1 mbar10 mbar50 mbar100 mbar100 mbar
* 0.01 % is a precision declaration
83
Functions
Type P L
Adjustment options
LinearisationTare / Zero
6 points
Selectable units
Pressure bar, mbar, kPa, MPa, PSI bar, mbar, hPa, kPa, MPa, PSI, mmHg, inHg, cmH2O, mH2O, inH2O, ftH2O, Kp/cm²
Features
Measuring inputsPC connection Analogue outputRelay outputBuilt-in versionExplosion protection (optional)
1 x directRS232 (optional)0(4)...20mA / 0...10 V (optional)2 x 24 VDC/1A (optional) (optional)
1 x directRS-485
Ex II 2G Ex ia II C T6
Data memory
Number of memoriesRecording intervalRecording durationData sets
Display / Representation
Multi-functional LCDBargraphIlluminationDisplay filterMin/max value
4 digit (0,5 % / 0,1 %), 5 digit (0,05 %)
5 digit
Measuring rate
StandardPeak / Fast
100 msec. 500 msec.
Process connection
Connection optionsMaterialMedium temperatureFor aggressive media
G½1.45420...50 °C
G¼1.44350...50 °C
Housing
Degree of protectionDimensionMaterialOperating temperatureWeight
IP65 (front) / IP4080 x 80 mm T=50 mm H=130 mmAluminium0...50 °C900 g
IP65 (front) / IP54Ø 80 mm T=40 mm H=120 mmABS plastic0...50 °C210 g
Power
Auto-off functionBattery typeExt. powerBattery operation
2x 1,5 V AAA24 VDC8000 h
1x 3 VCR
2000 h
84
PC connection and software
Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements and all data can be exported using standard programs such as Microsoft Excel. Remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available.
Accessories
85
Software package
Function AnalyserLight DEMO PressKAL CCS30 EBS20M SOFT3050
Memory managementJ PC download / delete / exportJ Storage interval settingJ Graphics function
Display managementJ Remote indicationJ Real time data recordingJ Storage interval settingJ Export function
Calibration managementJ Remote indicationJ Set up calibration routinesJ Set up calibration certificates
References
R PR
P L CompleteMH series
MH 3181MH 3151MH 3158
86
Comparison of digital and analogue pressure gauges
Pressure calibration is the comparison between the indicated values of a pressure measuring device with the indicated values of a pressure standard with a known accuracy. In many cases, the device to be tested cannot be removed from the active process. Calibration is performed on site to avoid lengthy downtimes. Portable SIKA pressure calibrators are especially suitable for this purpose.In order to perform a specified functional test or accuracy check, the test sample is often connected to the calibration device with a pressure hose. Digital pressure gauges with sufficient precision can be used as compact reference instruments.
Manual test pumps or pressure generators are used for simple pressure generation. SIKA offers a complete range of pressure calibrators for a wide variety of applications to allow specified test and calibration tasks to be performed. Routine on-site calibrations can be performed very quickly and economically with the right combination of pressure generator and reference. This ensures that the indicated pressure values are correct and reliable and that all specified requirements are fulfilled.
Pressure calibrators
-87-87
All manual pressure pumps and references can be combined as indicated above for various measuring ranges, resolutions and accuracy classes.
Possible combinations
Reference A Reference E-Ex Reference E2 Reference D-Ex Reference D2 Reference R Reference P Reference L
P 40.2 PM 40.2 A PM 40.2 E-Ex PM 40.2 E2 PM 40.2 D-Ex PM 40.2 D2 PM 40.2 R PM 40.2 P PM 40.2 L
P 60 PM 60 A PM 60 E2 PM 60 D2 PM 60 R PM 60 P
P 350.1 PM 350.1 A PM 350.1 E-Ex PM 350.1 E2 PM 350.1 D-Ex PM 350.1 D2 PM 350.1 R PM 350.1 P PM 350.1 L
P 700.2 PM 700.2 A PM 700.2 E2 PM 700.2 D-Ex PM 700.2 D2 PM 700.2 R PM 700.2 P PM 700.2 L
P 700.G PM 700.G A PM 700.G E-Ex PM 700.G E2 PM 700.G D-Ex PM 700.G D2 PM 700.G R PM 700.G P PM 700.G L
P 1000.1 PM 1000.1 E2 PM 1000.1 D2 PM 1000.1 R PM 1000.1 P PM 1000.1 L
88
Type PC 700+
Accuracy 0.025 %
Pressure ranges (Resolution) 0...60 bar (5 mbar)0...200 bar (20 mbar)0...350 bar (30 mbar)0...700 bar (70 mbar)
Functions
Adjustment optionsTare / Zero
Selectable units (pressure) bar, PSI, kPa, MPa, atm, at (kgf/cm²), mmHg, mHg, inHg, cmH2O, mH2O, inH2O, torr
Features
Measuring inputsPC connectionExplosion protectionElectronic measuring inputs
1 x directRS232EEx ia IIC T40...30 mA / 0...15 V
Data memory
Store function 30 x 10 values (manual)
Display / Representation
Multi-functional LCDIlluminationDisplay filterMin / max value
5 digit
Measuring rate
Standard 100 msec.
Process connection
Connection optionsMaterialMedium temperatureFor aggressive media
G¼2.4602-20...80 °C
Housing
Degree of protectionDimension, weightMaterialOperating temperature
IP65 (front) / IP40350 x 160 x 180 mm, 8.1 kgAluminium0...50 °C
Power
Auto-off functionBattery type, battery operationExt. power
1x 9 V Block, 35 h12 VDC
89
Calibrator PC 700+
90
91
SIMULATORS
J Monofunction simulators
J Multifunction simulators
DS_Simulators 05/2014
92
Simulators measure and generate diverse process variables. These portable and extremely handy instruments are ideal for on-site use. In addition to electrical signals such as current, voltage and resistance, further variables such as temperature, pressure and frequency can be measured and additionally generated.
The implemented sensor functions simulate specific supply variables and display an exact given value. This distinguishes a signal calibrator from the conventional measuring functions of a multimeter.
Simulators
Measurement and simulation of process signals
Simulators simplify service routines with the combination of measuring input and signal output and features that include special functions for repair, maintenance and troubleshooting in industrial installations.
These process calibrators allow comprehensive testing of control equipment, measuring instrument accuracy and reproducibility. The documentation of calibration results is also actively supported with internal memory and display functions or convenient external control via PC software.
93
Main applications
• Service, maintenance and repair
• Quality assurance
• Testing laboratories and research
• Instrumentation and control
• Process industry
• Energy supply
• Machine and apparatus engineering
Numerous other applications are also possible.
SIKA simulators have been developed for simple and flexible calibration and maintenance. Various tests can be performed in a single operation without having to change instruments. This saves time.
A wide range of highly reliable cutting-edge instruments is available to suit every application. Our highly accurate multifunction calibrators have been designed for a broad spectrum of applications and offer best value for money.
What this means in precise terms: being mobile and more versatile with a modern, convenient, compact and lightweight instrument.
94
Mono + Mono = Multi
Brief description
The combination of different types of signals determines the simulator type and its specific features. Whereas monofunction simulators can only process one type of signal, multifunction simulators can process different types of signals.
Available are resistance thermometers (RTD) and thermocouples (TC) with varying linearisation and corresponding resistance (Ω) and voltage signals (mV). Analogue current (mA) and voltage signals (V) as well as frequency (Hz) and pulse signals (O / C) and pressure signals (bar) round off the spectrum.
Monofunction simulatorsSIKA monofunction simulators offer exceptional performance, durability and reliability. Our temperature or current loop calibrators are compact, lightweight and easy to transport. These instruments feature rubber keys for ease of use and are insensitive to dust and splashing water. The tough plastic housing is resistant to shocks and impacts and offers additional protection against vibrations in harsh environments. Screened 4 mm sockets allow quick and easy connection of equipment to be tested.
Multifunction simulatorsSIKA multifunction simulators combine the functions of several devices in one instrument. These simulators are designed for easy generation and measurement of temperature, pressure, frequency and electrical signals. These documenting instruments have been developed for testing and calibration of numerous process signals as well as their generation and measurement with high accuracy. Operation is intuitive via keypad or pull-down menus.
94
95
Features
Multifunction displayThe back-lit multifunction display ensures clear indication of input and output values as well as all adjustments.
Operating concepts
Features include a rubber keypad, convenient interactive menu control via function keys, navigator and numeric keypad. These features allow easy selection and display of numerous functions.
Connection options
A large, switchable double display shows the connection options in graphic form. The 4 mm safety sockets ensure quick and easy connection of equipment to be tested. Connection takes place via laboratory connectors. Alternatively, bare cable ends can be connected without further adaptation via a Push & Lock function. Separate channels allow parallel system processing. This obviates the need for reconnecting the leads, which saves time and increases efficiency.
Push & Lock function
95
96
Manual call
Signals can be adjusted manually for different output levels for testing and calibration as required. The required value is output after configuration.
High-speed call
Signal values needed time and again are permanently or flexibly stored in the simulator and can be recalled quickly at the push of a button.
Steps and ramps
An automatic program is generated for periodic calls. The type of signal, duration and value are defined. Start delay, number of repetitions and a continuous linear increasing or decreasing characteristic can be individually programmed.
Synthesizer
The synthesiser function can be used for the generation of a discontinuous characteristic with changing signal values. Previously programmed changing signal levels are displayed on the simulator.
This function allows the simple definition and successive call of different steps, ramps or synthesiser values for easier testing.
Wide range of functions
t in Sek.Treppen-Funktion
t in Sek.Rampen-Funktion
t in Sek.Synthesizer-Funktion
Steps function
Ramp function
Synthesiser function
97
Calibration and linearisation pointsIf the measuring characteristics and deviations of a sensor are known and these are available in the form of a calibration certificate, they should be taken into account in measurement to obtain accurate measuring results.
The simulator input can be shifted linearly by offset programming to approach the measuring characteristics of the sensor. This single-point calibration is the simplest and most popular method for improving measuring results.
Multipoint calibration can be used for greater measuring accuracy. The input is configured by means of four linearisation points to the real sensor characteristics to compensate for linearity errors. Up to five different calibration data files can be directly stored and easily recalled as required.
User-defined characteristics
Measurement is often based on ideal linear characteristics. In normal practice, sensors, transmitters, transducers, etc., are often subject to non-linear characteristics due to various offset, gradient, linearity or hysteresis errors.
For the faultless measurement or generation of such non-linear characteristics, the measuring input or signal output can be configured with up to ten points by the user. The unit relating to the value is freely editable.
PC connection and memoryA remote control can be connected and all programming carried out via a USB port and PC software. The internal configuration memory of the simulator stores diverse testing and calibration data. These configuration files can easily be retrieved locally and preset functions selected at the push of a button.
Measured values can be stored as required. The data memory allows direct display of tables or graphs on the multifunction display. This enables complete test reports to be stored in the simulator and uploaded to a PC as required.
Software package
Function DataCalLight DataCal
Memory managementJ PC download / delete / exportJ Real time data recording J Value tables / graphics function
Configuration managementJ Adjust signals / functionJ PC-Upload
Calibration managementJ Set up calibration routinesJ Set up calibration certificates
Display managementJ Remote indicationJ Start / Stop of simulation
Types
UC RTD / UC TC / MC 75
t in Sek.Benutzerdefinierte Kennlinie mit 10 StützstellenUser defined characteristics with 10 points
98
Monofunction simulators
EC RTD and UC RTD
Signals EC RTD UC RTD
Resistance thermometer (RTD)
Generation and measurement of RTD signals Pt100, Cu50 Pt50, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50, Ni100, Ni120, Ni1000
Ω-generator function 0...400 Ω 0...3500 Ω
Ω-measurement function 0...450 Ω 0...3600 Ω
Accuracy (of rdg. + const.) ±0.05 % ±0.0012 %
Selectable temperature unit °C / °F °C / °F
Measurement of multi-wire connections 2 2 / 3 / 4
Type UC RTDType EC RTD
99
Functions EC RTD UC RTD
Generation
High-speed call values 10 points (flexible)
Linear steps and ramps
User-defined synthesiser values 10
User-defined signal output characteristic 10 points
Editable units
Output zero
Measurement
Data memory 10 000 values
Value tables and graphics function
Offset programming for sensor characteristic
Calibration data files and linearisation points 5 x 4 values
User-defined measuring input characteristic 10 points
Editable units
Measured value min. / max.
Measured value hold function
Averaging function
EC RTD
• Operator guidanceKeypad
• Battery supply / Operating timeApprox. 25 h with Auto-Power off
UC RTD
• Operator guidanceMenu with pull-down windowsProgramming and control via PC
• Battery supply / Operating timeApprox. 40 h
• Accu set with mains adapter (optional)
• Software (optional)
100
EC TC and UC TC
Signals EC TC UC TC
Thermocouples (TC)
TC signal generation and measurement J, K, T, R, S, B, N, E J, K, T, R, S, B, N, E, U, L, C
mV generator function -10...1100 mV -9.5...80 mV
mV measurement function -10...110 mV -10...100 mV
Accuracy (of rdg. + const.) ±0.05 % ±0.02 %
Selectable temperature unit °C / °F °C / °F
Internal comparison point ±0.5 °C ±0.3 °C
Type UC TCType EC TC
101
Functions EC TC UC TC
Generation
High-speed call values 10 points (flexible)
Linear steps and ramps
User-defined synthesiser values 10
User-defined signal output characteristic 10 points
Editable units
Measurement
Data memory 10 000 values
Value tables and graphics function
Sensor characteristic offset programming
Calibration data files and linearisation points 5 x 4 values
User-defined measuring input characteristic 10 points
Editable units
Measured value min. / max.
Measured value hold function
Averaging function
EC TC
• Operator guidanceKeypad
• Battery supply / Operating timeApprox. 25 h with Auto-Power off
UC TC
• Operator guidanceMenu with pull-down windowsProgramming and control via PC
• Battery supply / Operating timeApprox. 40 h
• Accu set with mains adapter (optional)
• Software (optional)
102
EC mAV and UC mAV
Type EC mAV UC mAV
Current (mA)
Loop current signal generation 0...22 mA 0(4)...25 mA
Loop current signal measurement -1...22 mA -6...25 mA
Accuracy (of rdg. + const.) ±0.02 % ±0.015 %
Current loop supply 24 V ±10 %, 22 mA 24 V ±10 %, 25 mA
HART communication protective resistor 250 Ω
Voltage (V)
Voltage signal generation 0...10(15) V
Voltage signal measurement -0.2...28 V -5...50 V
Accuracy (of rdg. + const.) ±0.02 % ±0.015 %
Continuity (O / C)
Continuity measurement O / C
Switching threshold "open" 15 kΩ 1 kΩ
Type UC mAVType EC mAV
103103
Functions EC mAV UC mAV
Generation
High-speed call values 7 points (permanent) in 25 % steps 10 points (flexible)
Linear steps and ramps
User-defined signal output characteristic 10 points
Editable units
Measurement
User-defined measuring input characteristic 10 points
Editable units
Measured value min. / max.
Measured value hold function
Averaging function
EC mAV
• Operator guidanceKeypad
• Battery supply / Operating timeApprox. 20 h
UC mAV
• Operator guidanceMenu with pull-down windows
• Battery supply / Operating timeApprox.25 h
• Accu set with mains adapter (optional)
104
EC 10 and EC 25
Multifunction simulators
Type EC 10 EC 25
Resistance thermometer (RTD)
RTD signal generation and measurement
Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50
Ω-generator function 0...4000 Ω 0...40 000 Ω
Ω-measurement function 0...5500 Ω 0...5500 Ω
Accuracy (rdg. + const.) ±0.05 %
Selectable temperature unit °C / °F
Measurement of multi-wire connections
2 / 3 / 4 2 / 3
Thermocouples (TC)
TC signal generation and measurement
J, K, T, R, S, B, N, E, U, L
J, K, T, R, S, B, N, E
mV generator function -100...1100 mV -100...110 mV
mV measurement function -50...550 mV
Accuracy (rdg. + const.) ±0.02 %
Selectable temperature unit °C / °F
Internal comparison point ±0.5 °C
Current (mA)
Loop current signal generation
0...22 mA
Loop current signal measurement
-5...55 mA
Accuracy (of rdg. + const.) ±0.02 %
Current loop supply 24 V ±10 %, 22 mA
Voltage (V)
Voltage signal generation
-1...11 V
Voltage signal measurement
-5...55 V
Accuracy (of rdg. + const.) ±0.02 %
Continuity (O / C)
Continuity measurement O / C
Switching threshold "open" 0.5 kΩ
Frequency and pulse (Hz)
Frequency and pulse signal generation
3 Hz...110 kHz
Frequency and pulse signal measurement
3 Hz...50 kHz
Accuracy (of rdg. + const.) ±0.005 %
Type EC 25
Type EC 10
105
Functions EC 10 EC 25
Generation
High-speed call values 7 points (fix) in 25 % steps
Linear steps and ramps
Output zero
Transmitter function simulation
Measurement
Measured value hold function
Averaging function
Room temperature display
EC 10
• Operator guidanceKeypad
• Battery supply / Operating timeApprox. 25 h with Auto-Power off
EC 25
• Operator guidanceKeypadSeparate channels for parallel signal processing
• Battery supply / Operating timeApprox. 20 h with Auto-Power off
105
106
MC 50 and MC 75
Type MC 75
Type MC 50 Type MC 50 MC 75
Resistance thermometer (RTD)
RTD signal generation and measurement
Pt50, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50, Ni100, Ni120, Ni1000
Ω generator function 0...4000 Ω
Ω measurement function 0...4000 Ω
Accuracy (of rdg. + const.) ±0.012 %
Selectable temperature unit °C / °F
Measurement of multi-wire 2 / 3 / 4
Thermocouples (TC)
TC signal generation and measurement
J, K, T, R, S, B, N, E, U, L
mV generator function 0...100 mV
mV measurement function 0...100 mV
Accuracy (of rdg. + const.) ±0.013 %
Selectable temperature unit °C / °F
Internal comparison point ±0.3 °C
Current (mA)
Loop current signal generation 0(4)...24 mA
Loop current signal measurement 0(4)...50 mA
Accuracy (of rdg. + const.) ±0.0175 %
Current loop supply 24 V ±10 %, 22 mA
HART communication protective resistor
250 Ω
Voltage (V)
Voltage signal generation 0...20 V
Voltage signal measurement 0...50 V
Accuracy (of rdg. + const.) ±0.015 %
Continuity (O / C)
Continuity measurement O / C
Switching threshold "open" 1 kΩ
Frequency and pulse (Hz)
Frequency and pulse signal generation
0.01 Hz...10 kHz
Frequency and pulse signal measurement
0.01 Hz...20 kHz
Accuracy (of rdg. + const.) ±0.005 %
Pressure signals (bar)
Pressure measurementwith external pressure module
Editable pressure units
Connection via DIN socket 5-pin
107
Further information on pressure measurement with the MC 75 simulator is provided on the next page.
Functions MC 50 MC 75
Generation
High-speed call values 10 points (flexible) 10 points (flexible)
Linear steps and ramps
User-defined synthesiser values 100 100
User-defined signal output characteristic 10 points 10 points
Editable units
Transmitter function simulation
Measurement
Data memory 10.000 values
Value tables and graphics function
Offset programming for sensor characteristic
Calibration data files and linearisation points 5 x 4 values
User-defined measuring input characteristic 10 points 10 points
Editable units
Measured value min. / max.
Averaging function
MC 50
• Operator guidanceSeparate channels for parallel signal processingMenu with pull-down windowsProgramming and control via PCGraphic display of connection optionsConfiguration files for test adjustments (10)
• Battery supply / Operating timeApprox. 25 h with Auto-Power off
MC 75
• Operator guidanceSeparate channels for parallel signal processingMenu with pull-down windowsProgramming and control via PCGraphic display of connection optionsConfiguration files for test adjustments (10)Test report generation / Calibration routines (10)
• Battery supply / Operating timeApprox. 20 h with Auto-Power off
• Software (optional)
107
108
MC 75
Pressure measurement
For universal on-site use, the MC 75 simulator is capable of measuring different pressures from -1 bar to 1000 bar.
The EPM plug-in modules are based on intelligent sensor technology with storage for measuring range and accuracy. Connection takes place via a DIN socket with Plug & Play function.
For the best measuring results with high accuracy, various absolute or relative pressure ranges in three precision classes are available.
Technical data
Measuring rate 400 measurements/sec.
Digital signals RS 485
Electrical connection 5-pin 1 m shielded connecting cable
Medium temperature 10…40 °C
Pressure connection G¼ stainless steel 1.4404
Degree of protection IP65
Dimensions Approx. D = 30 mm, L = 110 mm
Weight Approx. 140 g
Type EPM - external pressure modul
109
Type Model 0.05 Model 0.025 Model 0.01
Precision ±0.05 % full scale ±0.025 % full scale ±0.01 % full scale Pressure range
1 -1...1 bar rel. (PR) 2 bar
0...1 bar abs. (PAA)
3 -1...3 bar rel. (PR) 5 bar
0…3 bar abs. (PAA)
4 -1…4 bar rel. (PR) -1…4 bar rel. (PA) 20 bar
0…4 bar abs. (PAA) 0…4 bar abs. (PAA)
7 -1…7 bar rel. (PR) -1…7 bar rel. (PA) 20 bar
0…7 bar abs. (PAA) 0…7 bar abs. (PAA)
10 -1…10 bar rel. (PR) -1…10 bar rel. (PA) -1…10 bar rel. (PA) 20 bar
0…10 bar abs. (PAA) 0…10 bar abs. (PAA) 0…10 bar abs. (PAA)
12 -1…12 bar rel. (PR) -1…12 bar rel. (PA) 60 bar
0…12 bar abs. (PAA) 0…12 bar abs. (PAA)
20 -1…20 bar rel. (PR) -1…20 bar rel. (PA) 60 bar
0…20 bar abs. (PAA) 0…20 bar abs. (PAA)
30 -1…30 bar rel. (PR) -1…30 bar rel. (PA) -1…30 bar rel. (PA) 60 bar
0…30 bar abs. (PAA) 0…30 bar abs. (PAA) 0…30 bar abs. (PAA)
40 -1…40 bar rel. (PA) -1…40 bar rel. (PA) 200 bar
0…40 bar abs. (PAA) 0…40 bar abs. (PAA)
70 0…70 bar rel. (PA) 0…70 bar rel. (PA) 200 bar
0…70 bar abs. (PAA) 0…70 bar abs. (PAA)
100 0…100 bar rel. (PA) 0…100 bar rel. (PA) 0…100 bar rel. (PA) 200 bar
0…100 bar abs. (PAA) 0…100 bar abs. (PAA) 0…100 bar abs. (PAA)
120 0…120 bar rel. (PA) 0…120 bar rel. (PA) 400 bar
0…120 bar abs. (PAA) 0…120 bar abs. (PAA)
135 0…135 bar rel. (PA) 0…135 bar rel. (PA) 400 bar
0…135 bar abs. (PAA) 0…135 bar abs. (PAA)
160 0…160 bar rel. (PA) 0…160 bar rel. (PA) 400 bar
0…160 bar abs. (PAA) 0…160 bar abs. (PAA)
200 0…200 bar rel. (PA) 0…200 bar rel. (PA) 400 bar
0…200 bar abs. (PAA) 0…200 bar abs. (PAA)
300 0…300 bar rel. (PA) 0…300 bar rel. (PA) 0…300 bar rel. (PA) 400 bar
0…300 bar abs. (PAA) 0…300 bar abs. (PAA) 0…300 bar abs. (PAA)
400 0…400 bar rel. (PA) 0…400 bar rel. (PA) 1000 bar
0…400 bar abs. (PAA) 0…400 bar abs. (PAA)
700 0…700 bar rel. (PA) 0…700 bar rel. (PA) 0…700 bar rel. (PA) 1000 bar
0…700 bar abs. (PAA) 0…700 bar abs. (PAA) 0…700 bar abs. (PAA)
1000 0…1000 bar rel. (PA) 0…1000 bar rel. (PA) 0…1000 bar rel. (PA) 1000 bar
0…1000 bar abs. (PAA) 0…1000 bar abs. (PAA) 0…1000 bar abs. (PAA)
PR: Relative pressure measuring cell, ambient pressure as zero pointPAA: Absolute pressure measuring cell, vacuum as zero pointPA: Absolute pressure measuring cell, ambient pressure as zero point
110
Contents
Types EC Mono
Types UC Mono
Contents
• 1 x 9 V monobloc battery
• 2 sets with safety instrument leads (4 mm) and alligator clips
• Nylon pouch
• Plastic case (optional)
• Works certificate / DKD calibration certificate (optional)
Contents
• 4 x 1.5 V AA batteries
• Rechargeable battery including power adapter 230 VAC / 12 VD (optional)
• 2 sets with safety instrument leads (4 mm) and alligator clips (optional)*
• Nylon pouch (optional)
• Plastic case (optional)
• Software / data cable (optional)
• Works certificate / DKD calibration certificate (optional)
* For type UC mAV included as standard ** Type UC TC with 2 safety sockets (1 channel).
200
mm
160
mm
100 mm
Dep
th 4
0 m
m, w
eigh
t 550
gD
epth
45
mm
, wei
ght 3
00 g
85 mm
Multifunction display LCD, 5½ digit
Test connection via 4 safety sockets (1 channel)
Keypad Key operation
ABS plastic with protective cover
Multifunction display LCD, 6 digit
Test connection via 4 safety sockets (1 channel)**
Keypad Function keys, navigator
ABS plastic with protective cover
PC connection USB type Mini B
111
Types EC Multi
Types MC Multi
Contents
• 4 x 1.5 V AAA batteries
• 2 sets with safety instrument leads (4 mm) and alligator clips
• Nylon pouch
• Plastic case (optional)
• Works certificate / DKD calibration certificate (optional)
Contents
• Rechargeable battery including power adapter 230 VAC / 12 VDC
• 4 sets with safety instrument leads (4 mm) and alligator clips (optional)*
• Plastic case (optional)
• Software / data cable (optional)
• Works certificate / DKD calibration certificate (optional)
* Type EC 10 with single LCD.
210
mm
110
mm
100 mm
210 mm
Dep
th 4
0 m
m, w
eigh
t 550
gD
epth
50
mm
, wei
ght 9
00 g
Multifunction display Double LCD*, 5½-digit, illuminated
Test connection via 8 safety sockets (2 channels)
Keypad Key operation
ABS plastic with protective cover
Multifunction display Double LCD, 2 x 6-digit, illuminated
Test connection via 8 safety sockets (2 channels) incl. Push Lock
Keypad Function keys, navigator, numeric keypad
ABS plastic with protective cover
PC connection USB Type B
112
Simulator selection table
BASIC SOLID
EC RTD EC TC EC mAV EC 10 EC 25
Signals
Resistance thermometer
Resistance signals
Thermocouples
Thermovoltage signals
Continuity measurement
Current signals
Voltage signals
Frequency / Pulse
Pressure measurement
Functions
High-speed call function
Step function
Ramp function
Synthesiser function
Averaging function
Measured value hold function
Measured value min. / max.
User-defined characteristic
Single-point linearisation (offset)
Multipoint linearisation
PC connection (USB)
HART communication
Protection Data memory Value
Table and graphics
Parallel signal processing
Connection via Push & Lock
Configuration memory
Calibration routines
External pressure modules
113113
PREMIUM
UC mAV UC RTD UC TC MC 50 MC 75
114
115
MF
CALIBRATION SERVICES
J Purpose of calibration
J Overview measured values
J Scope of accreditation
DB_Calibration_services 05/2014
116
The purpose of calibration
Correct and reliable measurements are prerequisites for all
high-quality industrial production. Among other things,
measuring and testing equipment is used for quantitatively
determining properties, as well as for controlling, regulating
and automating processes used in manufacturing. Measure-
ments are therefore an important element of industrial quality
assurance, as can be seen in DIN EN ISO 9000 and 9001.
All equipment used for measurements, including equipment for
auxiliary measurements, e. g. of environmental conditions, and
which have a significant influence on the accuracy and validity
of the result of the test or sampling, must be calibrated prior
to use.
To ensure the accuracy of measurement results, the
measuring instruments, test equipment and standards
must be referred back to SI units. All standards are
almost the same – but not quite. This is because the
different standards within the calibration hierarchy
are regularly compared to a fixed hierarchical
structure.
Measuring devices must be calibrated. In other words,
the deviation of the device reading from the correct
value of the measured quantity must be known.
PTBNationalStandard
Accredited DKD laboratory
ReferenceDKD certificate
Internalworks laboratory
Company standardsWorks certificates / Test certificates
Calibrator
Test equipment of the company
117
At the very bottom of the hierarchy are the many different pieces
of test equipment within a company. In terms of temperature
measurement technology, these include desktop or hand-held
instruments, for example. Manual measuring instruments and
digital or analogue manometers are frequently used in pressure
measuring technology.
Since this test equipment wears, ages or drifts as a result of
constant use, it must be regularly connected to a company
standard. In the case of temperature or pressure measurement,
this standard is a temperature or pressure calibrator, which is
very often kept in protective storage in the company laboratory
and used solely for calibration purposes.
These calibrators are in turn regularly connected and tested
with standardsof the next higher hierarchy level, such as a
reference standard of a DKD laboratory.
At the very end of this closed chain is the national standard.
In Germany, the Physikalisch-Technische Bundesanstalt
(PTB) is responsible for realising and disseminating SI units.
It collaborates closely with the national metrology institutes
(NMI) in other countries to ensure the international equivalence
of measurement findings.
The following questions frequently arise: Are we actually using
the same dimensions? And do our instruments all operate
in the same way? So it is not surprising that reference to the
national standards is increasingly becoming the „norm“.
The decision as to which stage in the calibration hierarchy one
should „enter“ at is largely determined by the required level of
measurement accuracy. The following rule of thumb applies:
The further down the hierarchy, the more stages of comparison
between the standards have already been completed. The
standard is less accurate - but calibration is usually cheaper
and faster because it is less complicated.
A national standard embodies the most accurate
realisation of the unit of the International System of
Units (SI) available in a country.
With a DKD-certified temperature or pressure
calibrator, the customer receives a very precise
company standard. This company standard allows
works test certificates to be created for existing test
equipment very cost effectively. Traceability to national standards
is thus ensured.
DEUTSCHER KALIBRIERDIENST
Dr. Siebert & Kühn GmbH & Co. KG * Struthweg 7-9 * D-34260 Kaufungen * Telefon: 0 56 05/ 8 03 - 0 * Fax: 0 56 05/ 803 - 54/ 60
Kalibrierlaboratorium für thermodynamische und elektrische Messgrößen/ Calibration laboratory for pressure and electrical measuring instruments
Akkreditiert durch die / accredited by the
Akkreditierungsstelle des Deutschen Kalibrierdienstes
Labor Messtechnik Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 D-34260 Kaufungen
DKD-K-13901
000086
Kalibrierschein Kalibrierzeichen DKD-K- 13901
Calibration certificate Calibration mark 2011-04
Gegenstand Object
Multifunktions-Temperaturkalibrator - Trockenblockfunktion (DB) -
Hersteller Manufacturer
Dr. Siebert & Kühn GmbH & Co. KG D-34260 Kaufungen
Typ Type
TPM165S-U
Fabrikat/Serien-Nr. Serial number
5904245
Auftraggeber Customer
Auftragsnummer Order No.
655 578
Anzahl der Seiten des Kalibrierscheines Number of pages of the certificate
3
Datum der Kalibrierung Date of calibration
2011-04-21
Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Über-einstimmung mit dem Internationalen Einheitensystem (SI). Der DKD ist Unterzeichner der multi- lateralen Übereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI). The DKD is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object recalibrated at appropriate intervals.
Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmigung sowohl der Akkreditierungsstelle des DKD als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift und Stempel haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the Accreditation Body of the DKD and the issuing laboratory. Calibration certificates without signature and seal are not valid.
Stempel Seal
Datum Date
Stellv. Leiter des Kalibrierlaboratoriums Deputy Head of the calibration laboratory
Bearbeiter Person in charge
118
Temperature LaboratoryThe temperature laboratory is accredited for temperatures
from -30 °C to 1300 °C. Thermocouples, indicating temperature
measuring and test instruments, as well as temperature block
calibrators can be calibrated within this measuring range.
Resistance thermometers can be calibrated between -30 °C
and 960 °C. The basis of each calibration is the international
temperature scale of “ITS-90”. Measurements are executed
in accordance with DKD calibration guidelines of the German
national metrology institute (PTB) for temperatures close
to defined fixed points. This ensures the best possible
determination of the temperature characteristic curve. If
desired, other temperature values (e.g. from real operational
areas) can be included in the calibration.
Calibration services
For Pressure, Temperature and Electrical ValuesThe creation of a calibration service according “DKD Deutscher
Kalibrierdienst” for temperature, pressure and electrical
measured values firmly continues and underlines the long
tradition and more than 100 years of experience which SIKA has
in this sector. SIKA temperature and pressure sensors, as well
as measure, test and calibration instruments are available with
either a works test certificate or DKD calibration certificate.
This guarantees the traceability of measured values to approved
(national) standards as specified by DIN EN ISO 9000 ff in
numerous areas. Our DKD laboratory is your competent contact
for recalibration. Our services also include calibration to DKD
guidelines or calibration on the basis of works test certificates
for external products.
118
119
Pressure LaboratoryThe calibration laboratory for “absolute pressure and positive
overpressure” allows the calibration of analogue and digital
pressure measuring devices and pressure sensors with an
electrical output signal (e. g. 0...10 V, 4...20 mA, ...). Calibration
is carried out as a comparison measurement against a dead
weight tester utilised as the DKD reference standard. The dead
weight tester is used to pressurise the instrument under test
with a defined pressure from 1...1200 bar. Depending on the
actual measuring range, the smallest possible measuring
uncertainties are 0.7 mbar.
Laboratory for Electric ValuesResistors and ohmmeters can be calibrated from 0 to 2 kΩ.
Depending on the resistance value, the smallest possible
measuring uncertainty is 0.1 mΩ. DC voltmeters and
transmitters can be calibrated between 0 and 20 VDC with a
smallest possible measuring uncertainty of 2 μV. DC testing
and measuring devices for standard signals (0)4...20 mA can
be calibrated with a smallest possible measuring uncertainty
of 0.05 μA.
119
120
Scope of accreditation
Measured value Measuring range Measurement conditions Uncertainty of measurement
Pressure
Absolute pressure Pabs 2...61 bar DIN EN 837DKD R 6-1EURAMET/cg-17
7.0 · 10-5 ·pabs, but not less than 0.70 mbar
2...61 bar> 61...1201 bar
7.0 · 10-5 ·pabs, but not less than 0.40 mbar7.0 · 10-5 ·pabs, but not less than 7.0 mbar
Positive overpressure pe 1...60 bar DIN EN 837DKD R 6-1EURAMET/cg-17
7.0 · 10-5 ·pe, but not less than 0.70 mbar
1...60 bar> 60...1200 bar
7.0 · 10-5 ·pe, but not less than 0.40 mbar7.0 · 10-5 ·pe, but not less than 7.0 mbar
Temperature
Resistance thermometers and direct indicating thermometer
0.00 °C Icepoint 10 mK
-30...0 °C Oil bath with Al-Block 30 mK
> 0...100 °C 15 mK
> 100...300 °C Silicon oil bath with Al-Block 25 mK
> 300...550 °C Salt bath 25 mK
> 550...660 °C Tube furnace with block of brass 0.25 K
Resistance thermometer > 660...960 °C Tube furnace 0.8 K
Noble metal thermocouples -30...550 °C Thermostatted bath 0.5 K
> 550...1100 °C Tube furnace 1.2 K
> 1100...1300 °C 1.8 K
Base metal thermocouples -30...200 °C Thermostatted bath 0.2 K
> 200...550 °C 1.0 K
> 550...1100 °C Tube furnace 1.5 K
> 1100...1300 °C 2.5 K
Temperature block calibrators -30...133 °C 0.2 K
> 133...660 °C 1.5 mK · t / °C
> 660...1000 °C 2.5 K
> 1000...1300 °C 4.5 K
Electrical Values
Indicators and simulators for thermocouples
-200...1750 °C Noble metal thermocouples 0.70 K
Base metal thermocouples 0.20 K
Indicators and simulators for resistance thermometer
-200...850 °C Direct resistance measuring
6 · 10-6 · R
Calibration with resistance simulator
10 mK
Voltage (DC) 0...0.1 V> 0.1...0.2 V> 0.2...20 V
2 µV4 µV50 · 10-6 · U
Current (DC) 0...2 mA> 2...20 mA
0.05 µA0.1 · 10-3 · l
Electrical resistance 0...2000 Ω 6 · 10-6 · R + 1 mΩ
0...25 Ω> 25...100 Ω> 100...400 Ω
AC measuring, 75 Hz 0.1 mΩ5 · 10-6 · R6 · 10-6 · R
121
Measured value Measuring range Measurement conditions Uncertainty of measurement Notes
Pressure
Pressure medium: Gas with gas / oil membrane seperationThe expected uncertainty of measurement of the used barometer is to be considered
Pressure medium: OilThe expected uncertainty of measurement of the used barometer is to be considered
Pressure medium: Gas with gas / oil membrane seperation
Pressure medium: Oil
Temperature
Calibration on fixed-point of temperatur
In comparison with resistance thermometer in thermostatted baths
In comparison with resistance thermometer
In comparison with thermocouples
In comparison with resistance thermometer
In comparison with resistance thermometer and thermocouples
In comparison with resistance thermometer
In comparison with resistance thermometer and thermocouples
In comparison with resistance thermometer
t = Measuring value °C
In comparison with thermocouples
Electrical Values
Indicators and simulators for thermocouples
-200...1750 °C Noble metal thermocouples 0,70 K
Base metal thermocouples 0,20 K
Indicators and simulators for resistance thermometer
-200...850 °C Direct resistance measuring
6 · 10-6 · R R = Measuring value
Calibration with resistance simulator
10 mK
Voltage (DC) 0...0,1 V> 0,1...0,2 V> 0,2...20 V
2 µV4 µV50 · 10-6 · U
U = Measuring value
Current (DC) 0...2 mA> 2...20 mA
0,05 µA0,1 · 10-3 · l
l = Measuring value
Electrical resistance 0...2000 Ω 6 · 10-6 · R + 1 mΩ
0...25 Ω> 25...100 Ω> 100...400 Ω
AC measuring, 75 Hz 0,1 mΩ5 · 10-6 · R6 · 10-6 · R
R = Measuring value
122
123
HAND-HELD INSTRUMENTS
J Series MH
J Series IR
DS_Hand-held_instruments 05/2014
Including products with:
124
Hand-held instruments
Series MH - for humidity, temperature and pressure
The handy and reliable instruments of the MH range are used
for measuring and recording humidity, temperature or pressure.
The MH range is very flexible and is equally suitable for simple
measurements and special applications.
Sensors and probesThe high accuracy of the signal detection and processing
is achieved by means of powerful sensors with electronic
linearisation of the characteristic curve. The correct probes are
available for a wide range of measuring tasks.
Operating comfortThe innovative design of the attractive housing and the advanced
technology make the sensors comfortable to operate. In mobile
use, all functions can be selected and carried out easily by
pressing the buttons. The membrane keypad guarantees
protection against dust and moisture.
Multi-function displayAs well as MIN / MAX values, hold function and the selected
unit of measurement, various calculation values, such as
temperature differential, pressure differential, dew point or
heat capacity can also be shown on the multi-function display.
Explosion protectionHand-held pressure measuring devices and pressure sensors
are available in EXI versions (EEx ib IIC T4-03ATEX0136X).
Inputs
-125-125
Automatic sensor recognition through standard DIN socket
provides a plug-&-play solution that is easy to install.
OutputsExtensive alarm functions via the display and buzzer, freely
scalable standard signal output and PC interface are available.
Data storage (Log functions)Some instruments in the MH range can store data. The
integrated memory records up to 16 200 measurement values.
The date and time is automatically added to the values. A real
time clock is integrated for this purpose.
Two log functions are available:
• In the STORE mode, data is transferred by means of pressing
a button and 99 records can be stored. The values stored are
shown directly on the display.
• In CYCLE operation, values are recorded automatically at
a pre-programmed interval. Up to 16 200 records can be
stored. The stored values are shown on a PC.
PC InterfaceTo transfer the measurement values and stored values to a
PC, the majority of the MH instruments are fitted with a serial
interface.
The EBS 20 M software packages are available with extensive
recorder and display functions, as is the SOFT 3050 for evaluation
of the logged and alarm values. Process sequences can then
be monitored and analysed clearly using the measurement
procedures recorded and visualised as well as all data can be
exported into standard programs e.g. Excel.
Alarm- & time displaysA visual and acoustic warning signal indicates when
measurements exceed or fall below a programmed alarm point.
Transmission via PC is also possible. All data can be displayed
with the year and date, thanks to the real time clock.
125125
126
MH 3710 and MH 3750
MH 3710
Digital universal temperature hand-held instrument
For use with Pt100 exchangeable sensors
• Inputs
1 x mini-DIN-socket for Pt100 / 4-wire
• Measuring ranges /resolution
-199.99...199.99 °C / 0,01 °C
200.0...850.0 °C / 0.1 °C
• Accuracy
±0.015 % full scale ±1 digit
• Units
°C and °F
• Outputs
Analogue output 0...1 V
Scalable for easy data readout
• PC-Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
Temperature hand-held sensors for MH 3710 and MH 3750
Pt100 Fig. on Page 125 Name Temperature range L D
Standard sensor Fig.1 GTF401 -50...400 °C 150 mm 3 mm
Spike sensor Fig.2 GES401 -50...400 °C 150 mm 3 mm
Surface sensor Fig.3 GOF401 -50...400 °C 300 mm 3 mm (head = 4 mm)
Air / gas sensor Fig.6 GLF401 -50...400 °C 100 mm 3 mm (head = 6 mm)
Type MH 3750
Hand-held instruments for temperature
127
MH 3750
Same as MH 3710
Additional logger-, alarm- and clock functions
User-specific sensor linearisation
• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
• Data storage (Log function)
STORE
99 data sets (temp1, time and date)
Manual data set reading via keystroke
CYCLE
16 200 data sets (temp1)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
User-defined characteristic curve
With this function, customer-specific curves can be used,
alongside the standard calculation of the resistance /
temperature characteristic curve in compliance with EN 60751.
The MH 3750 has a very high accuracy of measurement. In order
to be able to exploit this high degree of accuracy, appropriate
high-quality temperature sensors must be used. Various
standard classes of accuracy are available for this purpose.
For applications that require a very high degree of accuracy
which is higher than the accuracy of the sensor itself, it is
recommended that the sensor be calibrated to the MH 3750 by
means of a user-defined characteristic curve.
For applications that require a very high degree of
accuracy which is higher than the accuracy of the
sensor itself, it is recommended that the sensor be
calibrated to the MH 3750 by means of a user-defined
characteristic curve. In this way, you can meet the
highest accuracy requirements in the range ≤ 0.05 °C.
Class B ± (0.3 + 0.005 |T|)Class A ± (0.15 + 0.002 |T|)Linearisation MH 3750
1,2
1
0,8
0,6
0,4
0,2
0
-50 0 50 100 150
Accu
racy
[°C
]
Temperature [°C]
0.3
0.15
0.05
128
Type MH 1150
Type MH 1170
MH 1150 and MH 1170
MH 1150
Digital temperature hand-held instrument
For use with NiCr-Ni-exchangeable sensors
• Inputs
1 x mini-TC-socket for thermocouple Type K
• Measuring ranges / Resolution
NiCr-Ni -50...1150 °C / 1 °C
• Accuracy
±1 % of rdg. ±1 digit
• Units
°C
MH 1170
Same as MH 1150
Extended resolution and accuracy
• Measuring ranges / resolution
Selectable resolution 0.1 °C or 1 °C
NiCr-Ni -65...199.9 °C or -65...1150 °C
• Accuracy
±0.05 % of rdg. ±0.2 % full scale ±1 digit
• Units
°C and °F
Temperature hand-held sensors for MH 1150, MH 1170, MH 3210, MH 3230 and MH 3250
Typ K Fig. Page 125 Name Temperature range L D
Standard sensor Fig.1 GTF900 -65...1000 °C 130 mm 3 mm
Fast response sensor Fig.1 GTF400 -65...550 °C 130 mm 1.5 mm
Spike sensor Fig.2 GES900 -65...1000 °C 100 mm 3 mm
Inconel sensor Fig.2 GTF1200 / 300 -200...1150 °C 300 mm 3 mm
Surface sensor Fig.4 GOF130CU -65...500 °C 130 mm 3 mm (head = 4 mm)
Surface sensor Fig.5 GOF130 -65...900 °C 130 mm 8 mm
Surface sensor Fig.7 GOF400VE -65...400 °C 100 mm 6 mm (head = 17 mm)
Surface sensor Fig.8 GOF400HO -65...400 °C 130 / 60 mm 6 mm (head = 17 mm)
Air / gas sensor Fig.6 GLF900 -65...600 °C 130 mm 3 mm (head = 6 mm)
129
MH 3210, MH 3230 and MH 3250
Temperature hand-held sensors for MH 3210, MH 3230 and MH 3250
Type N Fig. Page 125 Name Temperature range L D
Standard sensor Fig.1 GTF101-N250 -50...1300 °C 250 mm 3 mm
MH 3210
Digital universal temperature hand-held instrument
For use with thermocouple exchangeable sensors
• Inputs
1 x mini-TC-socket for thermocouples K / J / S / T / N
• Measuring ranges / resolution
Selectable resolution 0.1 °C or 1 °C
Type K NiCr-Ni -220...1370 °C
Type T Cu-CuNi -200...1100 °C
Type J FeCu-Ni -200...1100 °C
Type N NiCrSi-NiSi -200...1300 °C
Type S Pt10Rh-Pt -50...1750 °C
• Accuracy
±0.2 % full scale ±1 digit
• Units
°C and °F
• Outputs
Analogue output 0...1 V
Scalable for easy data readout
• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
MH 3230
Same as MH 3210
Additional measuring input
Differential measurement and TARE
Without analogue output
• Inputs
2 x mini-TC-socket for thermocouples K / J / S / T / N
MH 3250
Same as MH 3230
Additional logger-, alarm- and clock functions
• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
• Data storage (Log function)
STORE
99 data sets (temp1, temp2, T2-T1, time and date)
Manual data set reading via keystroke
CYCLE
9999 data sets (temp1, temp2, T2-T1)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
Type MH 3250
130
MH 175
MH 175
Digital temperature hand-held instrument
For use with Pt1000 exchangeable sensors
• Inputs
1 x jack-socket for Pt1000 / 2-wire
• Measuring ranges / resolution
-70.0...199.9 °C / 0.1 °C
• Accuracy
±0.1 % of rdg. ±1 digit
• Units
°C
Type MH 175
Temperature hand-held sensors for MH 175
Pt1000 Fig. Page 125 Name Temperature range L D
Standard sensor Fig.1 GTF175 -70...200 °C 100 mm 3 mm
Fast response sensor Fig.1 GTF175-1.6 -70...200 °C 100 mm 1.6 mm
Spike sensor Fig.2 GES175 -70...200 °C 100 mm 3 mm
Surface sensor Fig.3 GOF175 -70...200 °C 100 mm 3 mm (head = 4 mm)
Air / gas sensor Fig.6 GLF175 -70...200 °C 100 mm 3 mm (head = 6 mm)
Cable sensor Fig.10 GTF2000 -70...200 °C 50 mm 5 mm
Frozen cargo sensor Fig.9 GGF175 -70...200 °C 100 mm 6 mm
131
Temperature sensors
For temperature hand-held instruments MH-Series
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
132
Types MH 3330 / 3350 , TFS 0100 E
Hand-held instruments for humidity and temperature
MH 3330 and MH 3350
MH 3330
Digital universal humidity / temperature hand-held instrument
For use with automatically recognizable exchangeable sensor
TFS 0100 E
• Inputs
2 x mini-DIN-sockets for capacitive polymer humidity sensor
with Pt1000 temperature sensor 1 x mini-DIN-socket for type K
surface temperature
• Measuring ranges / resolution
Humidity 0.0...100.0 % r.H. / 0.1 %
Temperature -40.0...120.0 °C / 0.1 °C
Surface temperature -80.0...250.0 °C / 0.1 °C
• Accuracy
Humidity ±0.1 % full scale
Temperature ±0.2 % full scale ±1 digit
Surface temperature ±0.5 % of rdg. ±0.5 °C ±1 digit
• Units
°C, °F, r.H.
• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
MH 3350
Same as MH 3330
Additional logger-, alarm- and clock functions
• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
• Data storage (Log function)
STORE
99 data sets (humidity, temp1, temp2, dew point, dew point
distance, heat content, time, date)
Manual data set reading via keystroke
CYCLE
5400 data sets (humidity, temp1, temp2, dew point, dew
point distance, heat content)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
Sensor TFS 0100 E
Measuring ranges / resolution Humidity 0.0...100 % rH / 0.1 % rH Temperature -40.0...120.0 °C / 0.1 °C
Measuring elements Humidity capacitive polymer sensorTemperature Pt 1000 / 2-wire
Accuracy Humidity ±2 % of rdg. Temperature 1/3 DIN Pt1000 (±0.1 °C ±0.005 [T])
Electrical connection PVC cable (1m) with mini-DIN-plug
Tube Anodized aluminium with plastic sensor head
Dimensions / weight 14 x 120 mm (D x L1) / approx. 110 g
133
Types MH 3161 and MH 3181
Hand-held instruments for pressure
MH 3161 and MH 3181
MH 3161
Digital universal pressure hand-held instrument with internal
piezoresistive pressure sensor for air and non-corrosive /
ionizing gases and fluids
• Pressure types
Overpressure, negative pressure, differential and absolute
pressure, air pressure/ barometer, vacuum
• Inputs
2 x metal connection plugs for pressure hose 6 x 1 mm
• Measuring ranges / resolution
-19999...19999 digit
• Accuracy
±0.2 % full scale (hysteresis and linearity)
• Units
mbar, bar, Pa, kPa, MPa, mmHg, PSI, mH2O
• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
• Measuring rate
4 measurements / sec.
MH3181
Same as MH 3161
Additional analogue output
Logger-, alarm- and clock functions
Selectable measuring rate and average calculation
• Measuring ranges / resolution
• Outputs
Analogue output 0...1 V
Scalable for easy data readout
• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
• Data storage (Log function)
STORE 99 data sets (measured value, min / max value, time, date)Manual data set reading via keystroke
CYCLE 9999 data sets (measured or average value, min / max value)Automatic data set reading in the set interval Adjustable measurement interval 1 sec...60 minutes
• Measuring rates
SLOW = 4 measurements / sec.
FAST = 100 measurements / sec.
PEAK = 1000 measurements / sec.
• Average calculation
Via integration of measurement values at the adjustable
interval
• Options
higher accuracy sensor (available from 350 mbar)
EXI-Version (EEx ib IIC T4 - 03ATEX0136X)
Type Measuring range Over load Resolution
MH 3181-01 -1...25 mbar (rel.) 100 mbar (0.01 mbar)
MH 3181-07 -10...350 mbar (rel.) 1 bar (0.1 mbar)
MH 3181-12 0...1300 mbar (abs.) 4 bar (1 mbar)
MH 3181-13 -100...2000 mbar (rel.) 4 bar (1 mbar)
Type Measuring range Over load Resolution
MH 3161-01 -1...25 mbar (rel.) 100 mbar (0.01 mbar)
MH 3161-07 -10...350 mbar (rel.) 1 bar (0.1 mbar)
MH 3161-12 0...1300 mbar (abs.) 4 bar (1 mbar)
MH 3161-13 -100...2000 mbar (rel.) 4 bar (1 mbar)
134
• Measuring rates
SLOW = 4 measurements / sec.
FAST = 100 measurements / sec.
PEAK = 1000 measurements / sec.
• Average calculation
Via integration of measurement values at the adjustable
interval
MH3156
Same as MH 3151
Additional measuring input
Expand logger function at CYCLE modus
• Inputs
2 x mini-DIN-socket
• Data storage (Log function)
CYCLE
4000 data sets (measurement1 or average1, min1 value,
max1 value) (measurement2 or average2, min2 value,
max2 value) (diff M1-M2 or diff AV1-AV2, diff min1-min2,
diff max1-max2)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
• Options
Higher accuracy sensor (available from 350 mbar)
EXI-Version (EEx ib IIC T4 - 03ATEX0136X)
MH 3111
Digital universal pressure hand-held instrument
For use with automatically recognizable exchangable sensors MSD
• Pressure types
Overpressure, negative pressure, differential and absolute
pressure, air pressure / barometer, vacuum (depending on
plugged sensor)
• Inputs
1 x mini-DIN-socket
• Measuring range
-19999...19999 digit
• Accuracy
±0.2 % full scale (hysteresis and linearity)
• Units
mbar, bar, Pa, kPa, MPa, mmHg, PSI, mH2O
• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
• Measuring rate
4 measurements / sec.
MH 3151
Same as MH 3111
Analogue output
Logger function, alarm and real time clock
Switchable measuring rate
• Outputs
Analogue output 0...1 V
Scalable for easy data readout
• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
• Data storage (Log function)
STORE
99 data sets (measured value, min / max value, time, date)
Manual data set reading via keystroke
CYCLE
9999 data sets (measured value or average value,
min / max value)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minute
Types MH 3111, 3151 and 3156
MH 3111, MH 3151 and MH 3156
135
Nylon type
Piezoresistive pressure sensor for air as well as non-corrosive /
ionizing gases and fluids with integrated sensor memory
• Inputs
2 x nylon connection plugs for pressure hose 6 x 1 mm
• Accurcy
±0.2 % full scale (hysteresis and linearity)
• Measuring ranges / resolution
• Electrical Connection
PVC cable (1m) with mini-DIN-plug
• Housing
Robust ABS plastic, Degree of protection IP65
• Dimensions
70 x 30 x 15 mm (H x D x W)
• Weight
Approx. 75 g
Stainless steel type
Piezoresistive pressure sensor for aggressive media,
water, gases, and fluids, with internal sensor memory
• Inputs
Stainless steel connection G¼
• Accuracy
±0.2 % full scale (hysteresis and linearity)
• Electrical connection
PVC cable (1 m) with mini-DIN-plug
• Housing
Stainless steel, Degree of protection IP65
• Dimensions Approx. 23 x 85 mm (Ø x L)
• Weight Approx. 175 g
• Measuring range / Resolution
•
• Options for nylon and stainless steel
Higher accuracy sensor (available from 350 mbar)
EXI-Version (EEx ib IIC T4 - 03ATEX0136X)
Types MSD 250 MRE and MSD 160 BRE
Type (st. steel) Measuring ranges Over load Resolution
MSD 100 MRE 0...100 mbar (rel.) 1 bar 0.1 mbar
MSD 250 MRE 0...250 mbar (rel.) 2 bar 0.1 mbar
MSD 400 MRE 0...400 mbar (rel.) 2 bar 0.1 mbar
MSD 1 BAE 0...1 bar (abs.) 5 bar 1 mbar
MSD 1 BRE 0...1 bar (rel.) 5 bar 1 mbar
MSD -1 / 1.5 BRE -1...1.5 bar (rel.) 10 bar 1 mbar
MSD -1 / 3 BRE -1...3 bar (rel.) 17 bar 1 mbar
MSD 2.5 BAE 0...2.5 bar (abs.) 10 bar 1 mbar
MSD 2.5 BRE 0...2.5 bar (rel.) 10 bar 1 mbar
MSD 4 BAE 0...4 bar (abs.) 17 bar 1 mbar
MSD 4 BRE 0...4 bar (rel.) 17 bar 1 mbar
MSD 6 BAE 0...6 bar (abs.) 35 bar 1 mbar
MSD 6 BRE 0...6 bar (rel.) 35 bar 1 mbar
MSD 10 BAE 0...10 bar (abs.) 35 bar 10 mbar
MSD 10 BRE 0...10 bar (rel.) 35 bar 10 mbar
MSD 16 BAE 0...16 bar (abs.) 80 bar 10 mbar
MSD 25 BAE 0...25 bar (abs.) 50 bar 10 mbar
MSD 25 BRE 0...25 bar (rel.) 50 bar 10 mbar
MSD 40 BRE 0...40 bar (rel.) 80 bar 10 mbar
MSD 60 BRE 0...60 bar (rel.) 120 bar 10 mbar
MSD 100 BRE 0...100 bar (rel.) 200 bar 0.1 bar
MSD 160 BRE 0...160 bar (rel.) 320 bar 0.1 bar
MSD 250 BRE 0...250 bar (rel.) 500 bar 0.1 bar
MSD 400 BRE 0...400 bar (rel.) 800 bar 0.1 bar
MSD 600 BRE 0...600 bar (rel.) 1200 bar 0.1 bar
MSD 1000 BRE 0...1000 bar (rel.) 1500 bar 1 bar
Pressure sensors MSD
For pressure hand-held instruments MH-Series
Type (Nylon) Measuring range Over load Resolution
MSD 2.5 MR -2...2.5 mbar (rel.) 200 mbar 0.001 mbar
MSD 25 MR -20...25 mbar (rel.) 300 mbar 0.01 mbar
MSD 350 MR -200...350 mbar (rel.) 1 bar 0.1 mbar
MSD 1.3 BA 0...1.3 bar (abs.) 4 bar 1 mbar
MSD 2 BA 0...2 bar (abs.) 4 bar 1 mbar
MSD 2 BR -1...2 bar (rel.) 4 bar 1 mbar
MSD 7 BA 0...7 bar (abs.) 10 bar 10 mbar
MSD 10 BR -1...10 bar (rel.) 10.5 bar 10 mbar
136
Software
Nearly all instruments in the MH range are fitted with a PC interface, so that the values measured and stored can be transferred and recorded onto a PC. Using the software and an interface converter, a cost-effective measurement data recording system can be easily constructed. The EBS 20 M software packages with extensive recording and display functions are available, as is SOFT 3050 for evaluation of the logged and alarm values. Process sequences can then be monitored and analysed clearly using the measurement
procedures recorded and visualised.
WINDOWS PC-software
With a convenient measurement data recording system, recorder, large display, data display for a maximum of 20 measuring
channels and graphic presentation of measurement values:
• Adjustable time and measurement value axis
• Adjustable starting and stopping conditions
• Individual labelling of axis
• Adjustable line thickness and colour
• Adjustable labelling of the measurement points
• Ddigital display of measurement values across the whole
screen
• Transfer, recording and archiving of the measurement values
• Adjustable sampling rate
• Large comment field
• Data storage as ASCII code
• Language: German or English can be selected
Interface converter
• Data connection with serial PC interface
• Electrically isolated and protected against short-circuits
• Connection to PC via 9-pin sub-D socket or USB plug
• Power supply directly via PC
Battery / mains and charger
• Regulated plug adapter
• NiCd battery, rechargeable
• Charger for NiCd battery
Service and carrying case / service bag
Hard shell case in various sizes with packing foam and click lock:
• Standard (275 x 229 x 83 mm)
• Large (394 x 294 x 106 mm)
• Service bag with nylon sensor cover
Accessories
137
To confirm the outstanding accuracy for applications in the
service sector, measurement and control workshops and in
quality assurance, works or DKD certificates are available to
you from our DKD laboratory.
.
Humidity/temperature certificates
• Works test certificate 9 measurement points with 20 %,
40 %, 60 %, 80 % (rising / falling) and room temperature
• DKD certificate on request
Temperature certificates
• Works test certificate 4 measurement points up to 650 °C
• DKD certificate 4 measurement points up to 500 °C
Pressure certificates
• Works test certificate 10 measurement points
• DKD certificate 10 measurement points
Certificates
DEUTSCHER KALIBRIERDIENST
Dr. Siebert & Kühn GmbH & Co. KG * Struthweg 7-9 * D-34260 Kaufungen * Telefon: 0 56 05/ 8 03 - 0 * Fax: 0 56 05/ 803 - 54/ 60
Kalibrierlaboratorium für thermodynamische und elektrische Messgrössen
Calibration laboratory for temperature, pressure and electrical measuring instruments
Akkreditiert durch die / accredited by the Akkreditierungsstelle des DKD bei derPHYSIKALISCH-TECHNISCHEN BUNDESANSTALT (PTB) Labor Messtechnik
Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 D-34260 Kaufungen DKD-K-13901
000033 Kalibrierschein
KalibrierzeichenDKD-K- 13901
Calibration Certificate
Calibration label 2006-03 Gegenstand Object
Temperaturmessgerät mit Pt100-Widerstandsthermometer Hersteller Manufacturer
Dr. Siebert & Kühn GmbH & Co. KG D-34260 Kaufungen Typ Type
MH3750 + GTF401 Fabrikat/Serien-Nr. Serial number540777 + 540777-1 Auftraggeber Customer
Auftragsnummer Order No.
540 777 Anzahl der Seiten des Kalibrierscheines Number of pages of the certificate
3Datum der Kalibrierung Date of calibration
16.03.06
Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Über-einstimmung mit dem Internationalen Einheitensystem (SI). Der DKD ist Unterzeichner der multi-
lateralen Übereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI). The DKD is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object recalibrated at appropriate intervals. Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen
der Genehmigung sowohl der Akkreditierungsstelle des DKD als auch des ausstellenden Kalibrierlaboratoriums.
Kalibrierscheine ohne Unterschrift und Stempel haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the Accreditation
Body of the DKD and the issuing laboratory. Calibration certificates without signature and seal are not valid. Stempel Seal Datum
Date
17.03.06
Stellv. Leiter des Kalibrierlaboratoriums Deputy Head of the calibration laboratory
O. Schilling
Bearbeiter Person in charge
O. Schilling
Dr. Siebert & Kühn GmbH & Co. KG · Struthweg 7 - 9 · 34260 Kaufungen
Telefon: (05605) 803-0 · Telefax: (05605) 803-54 / 60 · Telex: 99717 sika d
MUSTER
Werksprüfschein 2008-09
Gerät: Pt100-Widerstandsthermometer + Anzeigegerät
Typ: GTF601+NH3750
Messbereich: 0….200 °C
Serien-Nr.: 598865-1 + 598865
Auftrags-Nr.:
Kunde:
Verwendete Normale und Messeinrichtungen:
DKD-Gebrauchsnormal Pt100, SN ASL-20,
Kalibrierzeichen 2339 DKD-K-09701/ 2008-03
Umgebungsbedingungen:
Umgebungstemperatur: RT (23±1)°C
Rel. Luftfeuchtigkeit: (50±20)%
Luftdruck: (990 ± 30)mbar
Messergebnisse:
Anzeige [°C]
Sollwert [°C]
Abweichung [°C]
0,00 - 0,003 +0,003
50,12 50,120 ±0,000
100,26 100,268 - 0,008
150,39 150,364 +0,026
199,73 199,732 - 0,002
Erstellt durch
Kaufungen, 24.09.2008
Labor Messtechnik
(O. Schilling)
Works Calibration Certificate
Temperature Temperature Humidity/Temperature Pressure
MH 3710 MH 3750 MH 1150 MH 1170 MH 3210 MH 3230 MH 3250 MH 175 MH 3330 MH 3350 MH 3161 MH 3181 MH 3111 MH 3151 MH 3156
Page 104 - 105 106 107 108 110 111 112
Measuring input Pt100 TC-K TC-K TC-K / J / S / T / N Pt1000 Capacitive polymer sensor / Pt1000 / TC-K
Internal sensor External sensor
Measuring ranges -199.99…199.99 °C200.0…850.0 °C
-50...1150 °C -65...199.9 °C200...1150 °C
-199.9…199.9 °C200...1750 °C
-70.0…199.9 °C 0…100.0 % rH-40.0…120.0 °C / -80.0…250 °C
-1...2000 mbar Depending on the chosen sensor MSD
Resolution0.01°C / 0.1 °C autorange 1 °C 0.1°C / 1 °C 0.1°C / 1 °C 0.1 °C 0.1 % rH / 0.1 °C 0.01 mbar
0.001 mbar...10 mbar, depending on the chosen sensor MSD
Units °C / °F °C °C / °F °C / °F °C % rH / °C / °F Mbar / bar / kPa / MPa / mmHg / PSI / mH2O
Display 2 x 4½ digit 3½ digit 3½ digit 2 x 4½ digit 3½ digit 2 x 4½ digit 2 x 4½ digit
Linearisation Offset / slope Offset / slope Offset / slope Offset / slope Offset Offset / slope Offset Offset / slope Offset / slope
Inputs 1 1 1 1 1 2 2 1 2 2 2 2 1 1 2
Analogue output
Logger function
PC-Interface
Alarm function (buzzer)
Clock / date(real time)
Sensor specific linearisation
EXI-Version
Auto-off function
Min-max-value
Hold-function
Correction value for surface measurement
Differential pressure
Tare-function
Sea-level- correction (abs.)
Extended measurementfunctions
• Differential measurement
• Difference function
• Dew point
• Dew point distance
• Heat content
• Average value
• Fast / PEAK / SLOW
• Average value
• Fast / PEAK / SLOW
138
Our products at a glance
Series MH
139
Temperature Temperature Humidity/Temperature Pressure
MH 3710 MH 3750 MH 1150 MH 1170 MH 3210 MH 3230 MH 3250 MH 175 MH 3330 MH 3350 MH 3161 MH 3181 MH 3111 MH 3151 MH 3156
Page 104 - 105 106 107 108 110 111 112
Measuring input Pt100 TC-K TC-K TC-K / J / S / T / N Pt1000 Capacitive polymer sensor / Pt1000 / TC-K
Internal sensor External sensor
Measuring ranges -199.99…199.99 °C200.0…850.0 °C
-50...1150 °C -65...199.9 °C200...1150 °C
-199.9…199.9 °C200...1750 °C
-70.0…199.9 °C 0…100.0 % rH-40.0…120.0 °C / -80.0…250 °C
-1...2000 mbar Depending on the chosen sensor MSD
Resolution0.01°C / 0.1 °C autorange 1 °C 0.1°C / 1 °C 0.1°C / 1 °C 0.1 °C 0.1 % rH / 0.1 °C 0.01 mbar
0.001 mbar...10 mbar, depending on the chosen sensor MSD
Units °C / °F °C °C / °F °C / °F °C % rH / °C / °F Mbar / bar / kPa / MPa / mmHg / PSI / mH2O
Display 2 x 4½ digit 3½ digit 3½ digit 2 x 4½ digit 3½ digit 2 x 4½ digit 2 x 4½ digit
Linearisation Offset / slope Offset / slope Offset / slope Offset / slope Offset Offset / slope Offset Offset / slope Offset / slope
Inputs 1 1 1 1 1 2 2 1 2 2 2 2 1 1 2
Analogue output
Logger function
PC-Interface
Alarm function (buzzer)
Clock / date(real time)
Sensor specific linearisation
EXI-Version
Auto-off function
Min-max-value
Hold-function
Correction value for surface measurement
Differential pressure
Tare-function
Sea-level- correction (abs.)
Extended measurementfunctions
• Differential measurement
• Difference function
• Dew point
• Dew point distance
• Heat content
• Average value
• Fast / PEAK / SLOW
• Average value
• Fast / PEAK / SLOW
140
Series IR
Infrared-temperature hand-held measuring instruments
Without infrared-thermometers are these measurements
almost unthinkable.
In this case, nothing is easier as operation according to the
motto: targeting – measuring – reading the measurement value.
In any area of non contact temperature measurement, SIKA
infrared thermometers are reliable partners due to the following
features: fully developed laser sight technology, very good
optical characteristics, and modern technology with adjustable
emissivity, data memory, and numerous additional functions.
Software
To create a high-performance temperature recording and
monitoring system, you only need the SIKA software package
and a PC. Temperatures measured by MaxiTemp 570 are
transferred to the PC via USB-Connection, where data are
monitored and evaluated graphically or tabular in form of a
company-specific test protocol.
Another highlight of the software package is the user-
specific setting of the MaxiTemp-measurement data memory.
You can program the alarm limit values, the emissivity, the
material, and the number of measurement locations for every
measurement point. Continuous measurement value recording
and determination of temperature for preventive maintenance
becomes an easy task with MaxiTemp, PC and software.
When it comes to temperature measurement technique and provided that a combination of simplest control and high measurement
accuracy is required, then infrared thermometers will always be the first choice. This choice becomes a must, if one of the following
requirements are given:
• Deterioration-free measurement of moving components
• Measurement of dangerous matter e.g. electrically life parts, chemically aggressive materials etc.
• Measurement in inaccessible locations
• Feedback-free measurement of small low-mass components
141
Measuring spots
Hand-held infrared measuring instruments measure the
surface temperature of an opaque object.
The instrument‘s optics detect emitted, reflected, and
transmitted energy, which is collected and focused onto a
detector.
The electronics translate this information into a temperature
measurement and display the temperature. The laser pointer is
only used as an pointing device.
To measure a temperature, the hand-held measuring
instrument is simply aimed at an object and the measurement
activated. Here, the distance and associated spot size is to be
observed.
The measuring spot size increases as the distance from the
object to be measured increases. The ratio between distance
and measuring spot size is represented as optical resolution.
The higher the optical resolution, the smaller the measuring
spot size is with the same distance.
Sensor
Very good
Measurement object larger
than measuring spot Measurement object smaller
than measuring spot
Measurment object
and measuring spot
equal in size
Good Wrong
Table of total Emissivity
To ensure a correct setting of the emission factor in the infrared
temperature measurement, please visit emissivity.sika.net and
download a table of total Emissivity.
142
Type MiniTemp 400
MiniTemp 400
Functions
Spectral range 8…14 µm
Laser pointer 1
Alarm
TC connection
Data Store
PC connection
Power supply 9 V
LCD lightning
°C / °F switchable
Bargraph display
Scan / Hold / Auto OFF
Permanent measuring (Lock)
Low Bat. indication
MIN / MAX store
AVA / DIF function
Accessories (incl.) Battery
Order code
MiniTemp 400 EME8ETIR400000
Technical data
• Temperature range -20...330 °C
• Resolution 0.1
• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
• Optical resolution 8 / 1
• Emissivity fix 0.95
Measuring points
Distance Size measuring points
200 mm 25 mm
400 mm 50 mm
800 mm 100 mm
143
Type SemiTemp 509
SemiTemp 509
Functions
Spectral range 8…14 µm
Laser pointer 2
Alarm Acustical high / low
TC connection
Data Store
PC connection
Power supply 9 V
LCD lightning
°C / °F switchable
Bargraph display
Scan / Hold / Auto OFF
Permanent measuring (Lock)
Low Bat. indication
MIN / MAX store Max
AVA / DIF function
Accessories (incl.) Battery
Order code
SemiTemp 509 EME8ETIR509000
Technical data
• Temperature range -20...510 °C
• Resolution 0.1
• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
> 500 °C: ±(3 % of rdg. + 1 °C)
• Optical resolution 12 / 1
• Emissivity 0.10...1.00
Measuring points
Distance Size measuring points
150 mm 12,5 mm
300 mm 25 mm
610 mm 50 mm
144
Type SemiTemp 515
SemiTemp 515
Functions
Spectral range 8…14 µm
Laser pointer 1
Alarm Acustical high / low
TC connection Type K
Data Store
PC connection
Power supply 9 V
LCD lightning
°C / °F switchable
Bargraph display
Scan / Hold / Auto OFF
Permanent measuring (lock)
Low Bat. indication
MIN / MAX store
AVA / DIF function
Accessories (incl.) Battery, TC-K
Order code
SemiTemp 515 EME8ETIR515000
Technical data
• Temperature range -35...800 °C
• Resolution 0.1
• Accuracy <500 °C: ±(2 % of rdg. + 2 °C)
>500 °C: ±(3 % of rdg. + 1 °C)
• Optical Resolution 12 / 1
• Emissivity adjustable 0.10...1.00
Measuring points
Distance Size measuring points
260 mm 20 mm
520 mm 40 mm
1040 mm 80 mm
145
Type SemiTemp 512
SemiTemp 512
Functions
Spectral range 8…14 µm
Laser pointer 2
Alarm Acustical high / low
TC connection
Data Store
PC connection
Power supply 9 V
LCD lightning
°C / °F switchable
Bargraph display
Scan / Hold / Auto OFF
Permanent measuring (lock)
Low Bat. indication
MIN / MAX store Max
AVA / DIF function
Accessories (incl.) Battery
Order code
SemiTemp 512 EME8ETIR512000
Technical data
• Temperature range -35...1000 °C
• Resolution 0.1
• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
> 500 °C: ±(3 % of rdg. + 1 °C)
• Optical Resolution 30 / 1
• Emissivity adjustable 0.10...1.00
Measuring points
Distance Size measuring points
150 mm 12,5 mm
300 mm 25 mm
610 mm 50 mm
146
Type MaxiTemp 570
MaxiTemp 570
Functions
Spectral range 8…14 µm
Laser pointer 2
Alarm Acustical (high / low)
TC connection Type K
Data Store 100
PC connection USB
Power supply 9V
LCD lightning
°C / °F switchable
Bargraph display
Scan / Hold / Auto OFF
Permanent measuring (lock)
Low Bat. indication
MIN / MAX store
AVA / DIF function
Accessories (incl.) Battery, TC-K, transport case, software, USB cabel, stand-base
Order code
MaxiTemp 570 EME8ETIR570000
Technical data
• Temperature range -35...1000 °C
• Resolution 0.1
• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
> 500 °C: ±(3 % of rdg. + 1 °C)
• Optical Resolution 50 / 1
• Emissivity adjustable 0.10...1.00
Measuring points
Distance Size measuring points
260 mm 20 mm
520 mm 40 mm
1040 mm 80 mm
147
Our products at a glance
Series IR
MiniTemp 400 SemiTemp 509 SemiTemp 515 SemiTemp 512 MaxiTemp 570
Temperature range -20…330 °C -20…510 °C -35…800 °C -35…1000 °C -35…1000 °C
Resolution 0.1 0.1 0.1
Accuracy< 500 °C> 500 °C
±(2 % of rdg. + 2 °C) ±(2 % of rdg. + 2 °C)±(3 % of rdg. + 1 °C)
±(2 % of rdg. + 2 °C)±(3 % of rdg.+ 1 °C)
Optical Resolution 8 / 1 12 / 1 12 / 1 30 / 1 50 / 1
Emissivity Fix 0.95 Adjustable 0.10…1.00
Spectral range 8…14 μm
Laser pointer 1 2 1 2 2
Alarm Acustical (high / low) Acustical (high / low)
TC connection Type K Type K
Store 100
PC connection USB
Power supply 9 V
LCD lightning
°C / °F switchable
Bargraph display
Scan / Hold / Auto OFF
Permanent measuring (lock)
Low Bat. indication
MIN / MAX store Max Max
AVA / DIF function
Accessories (incl.) Battery Battery Battery, TC-K Battery Battery, TC-K, trans- port case, software, USB cabel, stand base
148
149
CONTROLLERS AND INDICATORS
J Controllers, series CON
J Indicators, series IND
DS_Controllers_and_indicators 05/2014
150
Electronic indicating instruments visualise physical signals from measurement sensors. For example, a resistance signal from a temperature sensor is shown in degrees Celsius on the indicating instrument.
Electronic controllers are used in applications where it is necessary to reach and maintain a particular level, such as a system temperature. The controller compares the actual measured process value with the desired value and independently generates an output signal that minimises the difference between the setpoint and actual values.
A wide variety of visualisation, control and monitoring tasks must be implemented in industrial processes. Even with simple applications, there is often a desire for more functions without large additional expense. The hardware and software are therefore designed to provide a maximum of flexibility.
High-performance microcontrollers with high computing Power supply and large memories enable the implementation of customer-specific requirements, so that you can find the optimal solution for your engineering task.SIKA‘s indicating and control instruments offer advantages that allow them to be used in many different applications.
SIKA performance features • Various dimensions for panel or rail mounting enable solutions for diverse installation situations
• Programmable measurement input ports make it easy to connect several measurement transducers and sensors
• Floating digital inputs provide additional options for control tasks
• RS 485 serial interface supports data transmission for process visualisation, centralised remote monitoring and networking
• Simplified parameter settings for effortless configuration with a PC
• Up to five outputs for implementing versatile monitoring and control tasks
• Input signal feedback via standardised linear analogue output reduces costs and component count
• Time-controlled activation of switch outputs eliminates the need for external timers and time switches
• An integrated programming function eliminates the need for complicated and expensive programmable controllers
• Input and output signal monitoring with loop or load control enhances process reliability
• Various automatic optimisation functions for control parameters simplify use, even with little knowledge of control engineering
• Customised OEM versions are possible to optimise the match between the indicating instrument or controller and your application
Effective implementation of visualisation and control tasks
151
Installation situationWe offer solutions for various installation situations. Our standard electronic displays and controllers are plug-in modules for convenient front-panel mounting or replacement. We also offer instruments for rail mounting.
If indication of setpoint and actual values is not necessary and little space is available for a control task, our blank controllers are the ideal solution. Parameter settings can be configured using a plug-in display and control module or a PC.
NetworkingNetworking of indicating instruments or controllers in a master / slave configuration is very easy using the RS 485 serial interface. This involves setting up a two-wire bus and using the well known and widely used ModBus protocol for communication. Integration into a higher-level control system can be implemented very easily with this approach.
A PC is often designated as the master, but this is not always possible or necessary. An individual instrument can also act as master, with the instruments communicating with each other without a PC. If
a setpoint value needs to be changed in such a network, it only needs to be changed in the master and all the slave instruments will follow automatically. This feature offers enormous savings in time and money.
152
Programming adapterThe TTL interface facilitates the configuration of instrument parameter settings with the programming adapter.The programming adapter is especially helpful when several instruments have to be configured with identical settings or when various configuration data sets have to be archived and retrieved as necessary.
Stand-alone parameter configuration allows a configuration data set to be transferred directly from the programming adapter to other instruments. The configuration data is initially loaded into the programming adapter from a master controller or a PC where the desired configuration is stored.
With PC-based parameter configuration using the software programming tool, the programming adapter acts as a converter between the instrument and the PC. The instrument‘s parameter data is transferred via the programming adapter directly to the PC and displayed. All parameters are shown in tablular form in the configuration software, and they can be modified. The modified parameters are then written directly back to the instrument. The data can also be saved in the PC, which enables retrieval of various parameter configurations.
Programming functionProgrammable controllers are used in applications where ramps and dwell times have a crucial effect on the quality of the final product.
Complex, customised control profiles with various process sequences in a single program can be defined with our controllers. For this purpose, the programming function is divided into eight segments and four groups. The program is started by a Run command from a button or an external control contact.
Extensive special functions
153
Monitoring functions Monitoring lower and upper limits is often necessary in addition to indication or control functions. A variety of alarm functions are available for this.
Programming the relay contact as normally closed (NC) or normally open (NO) ensures that the desired behaviour is always obtained and provides a fault indication in the event of Power supply failure.
Absolute or relative lower and upper limits as well as window alarms enable user-programmable alarm zones. An alarm signal is generated automatically if process values go outside the monitoring range.
If it is necessary to maintain the alarms and continuously indicate an alarm condition that has occurred, or if for safety reasons an additional manual action must occur, alarm memories with acknowledgement by a button or an external contact provide a suitable solution.
Some applications need a defined start-up phase in order to attain the desired operating state. If it is necessary to prevent false alarms during this phase, start-up alarm suppression or an alarm time delay can be programmed.
Timer functionFor some applications, time-controlled activation of switch outputs is necessary in addition to process parameter monitoring or control. This timer function can be integrated in SIKA controllers with no need to install additional components. That saves space and reduces cost.
The on and off times can be programmed in hours, minutes or seconds. In the various operating modes, time control can be started, paused or disabled by a button press or an external control contact.
Sensitive touchSome instruments are optionally available with the new sensitive touch buttons for soft touch operation, in place of the
standard rubberised buttons. The sensitive touch buttons are based on capacitive touch technology and are actuated by finger contact with the glass front. Along with modern design, the sensitive touch option offers easier cleaning and better moisture
and dirt immunity. Special applications can be implemented easily and compactly.
154
Technical data E 51 A W 09
Control characteristics 2-point (on / off)
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0.5 % full scale + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
Outputs
Output OUT1J Relay (100 000 cycles)J Relay (50 000 cycles)
SPST, 16 A / 6 A / 250 VACSPDT, 16 A / 6 A / 250 VAC
SPDT, 8 A / 3 A / 250 VAC
DisplayJ 7-segment LED
Single-row3-digit, red , 14 mm
Single-rowSigned 3-digit with sign , red or blue , 14 mm
ResolutionJ Temperature 1 °C or 0.1 °C over the range -19.9...99.9 °C 1 °C or 0.1 °C over the range -99.9...99.9 °C
Temperature units °C, °F
Power supply 12 VAC / DC ±10 %, 50 / 60 Hz24 VAC / DC ±10 %, 50 / 60 Hz115 VAC ±10 %, 50 / 60 Hz230 VAC ±10 %, 50 / 60 Hz
100...240 VAC, ±10 %, 50 / 60 Hz
Housing E 51 A W 09
Degree of protection (front) IP65
Connections Screw terminal connection
Dimensions (W x H x D) 65 x 33 x 50 mm 75 x 122 x 34 mm
Controller, series CON
E 51 A and W 09
Configuration TLZ 35 W 09
Parameter configuration input TTL 5-pin
155
Order example E51A F N R
Power supply
12 V24 V115 V230 V
FACD
Measuring inputs
NTCPTC
NP
OUT1
Relay, SPSTRelay, SPDT
RS
Order example W09 H R B
Power supply
100...240 V H
OUT1
Relay R
Buzzer
Alarm buzzerWithout buzzer
B-
Type E 51 A
Type W 09
156
Technical data TCPDE M
Control characteristics 2-point (on / off), hysteresis 3 °CPD (P-Band 10 °C, reset time 25 sec.)
Inputs
Resistance thermometerJ Pt100 / 3-wire 0...100 / 200 / 250 / 350 °C ±1 % full scale
ThermocoupleJ Typ JJ Typ K
0...100 / 200 / 250 / 350 / 600 / 1000 / 1100 / 1200 °C ±2 % full scale0...100 / 200 / 250 / 350 / 600 / 1000 / 1100 / 1200 °C ±2 % full scale
Outputs
Output OUT1J Relay (100 000 cycles)J Relay (50 000 cycles)J Solid-state relay connection
SPDT, 8 A / 3 A / 250 VAC
24 VDC, 20 mA
DisplayJ 7-Segment LED Different scales
ResolutionJ Temperature 1 °C over the range
Temperature units °C
Power supply 24...240 VAC ±10 %, 50 / 60 Hz
Housing TCPDE M
Degree of protection (front) IP54
Connections Faston plug (6.3 mm)Octal plug (8 Pin) with screw terminal
Dimensions (W x H x D) 48 x 48 x 107 mm
TCPDE M
157
Type TCPDE M Oder example TCPDEM 1 U J R F O Z
Scale*
0...100 °C0...200 °C0...250 °C0...350 °C0...600 °C0...1000 °C0...1100 °C0...1200 °C
12834697
Power supply
24...240 V U
Measuring inputs*
TC JTC KPt100
JKP
OUT1
RelaySSR
RO
Connection
FastonOctal
FO
Control function
2-pointPD
OP
Plug base
Octal bush Z
* Measuring input Pt100 up to max. 350 °C
158
Technical data TLZ 35 R 38
Control characteristics 2-point (on / off) 2-point (on / off), 3-point (neutral zone), PID
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0.5 % full scale . + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
-50...150 °C ±0.5 % full scale + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
Resistance thermometerJ Pt100 / 3-wireJ Pt1000 / 2-wire
-50...850 °C ±0.5 % full scale + 1 digit-50...850 °C ±0.5 % full scale + 1 digit
ThermocoupleJ Type JJ Type K
-40...999 °C ±0.5 % full scale + 1 digit-40...999 °C ±0.5 % full scale + 1 digit
Outputs
Output OUT1J Relay (100 000 cycles)J Relay (50 000 cycles)J SSR drive
SPST, 16 A / 6 A / 250 VACSPDT, 16 A / 6 A / 250 VAC
SPDT, 8 A / 3 A / 250 VAC
10 VDC, 10 mA
Output OUT2J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC SPDT, 8 A / 3 A / 250 VAC10 VDC, 20 mA
DisplayJ 7-segment LEDJ Supplementary display
Single-row4-digit, red, 12 mm Drift indicator actual and setpoint value
Single-row3-digit, red or blue, 12 mm
ResolutionJ Temperature 1 °C or 0.1 °C over the range 1 °C or 0.1 °C over the range -50.0...99.9 °C
Temperature units °C, °F
Power supply 12 VAC / DC ±10 %, 50 / 60 Hz24 VAC / DC ±10 %, 50 / 60 Hz100...240 VAC ±10 %, 50 / 60 Hz
Housing TLZ 35 R 38
Degree of protection (front) IP40 IP65
Connections Screw terminal connection Screw terminal connection
Dimensions (W x H x D) 70 x 84 x 60 mm 75 x 33 x 64 mm
Configuration TLZ 35 R 38
Parameter configuration input TTL 5-pin TTL 5-pin
Control input 1 floating input
Sensitive touch keys Capacitive touch-keys
Other Alarm buzzer
TLZ 35 and R 38
159
Order example TLZ35 F N R R B
Power supply
12 V24 V100...240 V
FLH
Measuring input
NTCPTC
NP
OUT1
Relay, SPSTRelay, SPDT
RS
OUT2
Relay, SPSTWithout OUT2
R-
Buzzer
Alarm buzzerWithout buzzer
B-
Order example R38 S F F R O B E
Operating keys
Rubber keysSensitive-touch-keys
-S
Power supply
12 V24 V100...240 V
FLH
Measuring input
TCPt100PTC + NTC + Pt1000
FAT
OUT1
RelaySSR
RO
OUT2
RelaySSRWithout OUT2
RO-
Buzzer
Alarm buzzer B
Connection block
Plug-in type incl. female connectorPlug-in without female connectorFix screw terminals
EN-
Type TLZ 35
Type R 38
160
Technical data TLK 96 S TLK 72
Control characteristics 2-point (on / off), 3-point (neutral zone), PID
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0.5 % full scale + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
Resistance thermometerJ Pt100 / 3-wire -50...850 °C ±0.5 % full scale + 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ 0...50 mV, 0(12)...60 mV
0...1000 °C ±0.5 % full scale + 1 digit0...1370 °C ±0.5 % full scale + 1 digit0...1760 °C ±1 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
Outputs
Output OUT1J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC8 VDC, 8 mA
Output OUT2J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC8 VDC, 8 mA
SPST, 8 A / 3 A / 250 VAC8 VDC, 8 mA
Output OUT3J Relay (100 000 cycles)J SSR drive
SPST, 8 A / 3 A / 250 VAC8 VDC, 8 mA
DisplayJ 7-segment LEDJ Supplementary display
Single-row4-digit, red, 14 mm Drift indicator actual and setpoint value
ResolutionJ TemperatureJ Current / voltage
1 °C or 0.1 °C over the range -199.9...999.9 °CFreely scalable, adjustable decimal point
Temperature units °C, °F
Power supply 24 VAC / DC ±10 %, 50 / 60 Hz100...240 VAC ±10 %, 50 / 60 Hz
Housing TLK 96 S TLK 72
Degree of protection (front) IP54 IP54
Connections Screw terminal connection Screw terminal connection
Dimensions (W x H x D) 96 x 96 x 73 mm 72 x 72 x 97 mm
Configuration TLK 96 S TLK 72
Parameter configuration input TTL 5-pin
Control input 2 floating inputs
Transmitter supply 12 VDC / 20 mA 12 VDC / 20 mA
COM interface Serial RS 485 (ModBus)
Other Adjustable debit value gradient Adjustable debit value gradient
TLK 96 S and TLK 72
161
Type TLK 96 S
Order example TLK96S L C R R R S I
Type
TLK 96 STLK 72
TLK96STLK72
Power supply
24 V100...240 V
LH
Measuring inputs
TC + Pt100 + mVTC + PTC + NTC + mV0(4)...20 mA0(1)...5 V + 0(2)...10 V
CEIV
OUT1
RelaySSR
RO
OUT2
RelayWithout OUT2
R-
OUT3*
RelaySSRWithout OUT3
RO -
Interface*
RS 485Without RS 485
S-
Control input*
1 floating inputWithout control input
I-
Type TLK 72
* OUT3, interface and control input only with TLK 72.
162
KR 1, KM 1 and KX 1
Technical data KR 1 KM 1 KX 1
Control characteristics 2-point (on / off), 3-point (neutral zone), PID, dual PID
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0,5 % full scale + 1 digit-50...109 °C ±0,5 % full scale + 1 digit
Resistance thermometerJ Pt100 / 3-wireJ Pt1000 / 2-wire
-200...850 °C ±0,5 % full scale + 1 digit-200...850 °C ±0,5 % full scale + 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ Type RJ Type TJ 0...50 mV, 0(12)...60 mV
-50...1000 °C ±0,5 % full scale + 1 digit-50...1370 °C ±0,5 % full scale + 1 digit-50...1760 °C ±1 % full scale + 1 digit-50...1760 °C ±0,5 % full scale + 1 digit-70...400 °C ±0,5 % full scale + 1 digit-1999...9999 ±0,5 % full scale + 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0,5 % full scale + 1 digit-1999...9999 ±0,5 % full scale + 1 digit
Outputs
Output OUT1J Relay (100 000 cycles)J SSR drive
SPDT, 4 A / 2 A / 250 VAC12 VDC, 15 mA
SPST, 4 A / 2 A / 250 VAC12 VDC, 15 mA
Output OUT2J Relay (100 000 cycles)J SSR drive
SPST, 2 A / 1 A / 250 VAC12 VDC, 15 mA
Output OUT3J Relay (100 000 cycles)J SSR drive
SPST, 2 A / 1 A / 250 VAC12 VDC, 15 mA
Output OUT4J SSR drive 12 VDC, 20 mA
DisplayJ 7-segment LEDJ Supplementary display
Double-row4-digit, red / green / orange, 15.5 mmSetpoint value indicator, green, 7 mm
Double-row and bar graph4-digit, red / green / orange, 15.5 mmSetpoint value indicator, green, 10 mm
ResolutionJ TemperatureJ Current / voltage
1 °C oder 0,1 °C over the range -199,9...999,9 °CFreely scalable, adjustable decimal point
Temperature units °C, °F
Power supply 24 VAC / DC ±10 %, 50 / 60 Hz100...240 VAC ±10 %, 50 / 60 Hz
Housing KR 1 KM 1 KX 1
Degree of protection (Front)
IP65
Connections Screw terminal connection (fix), screw terminal connection (flex)
Dimensions (W x H x D)
75 x 33 x 78 mm
48 x 48 x 63 mm
48 x 96 x 76 mm
Configuration KR 1 KM 1 KX 1
Parameter configuration input TTL 5-pin
Control input 1 or 2 floating input
Transmitter supply 12 VDC / 20 mA
Timer / Programmer 2 timer, 5 functions
COM interface Serial RS 485 (ModBus)
Other Dynamic display, Eco-Mode
163
* OUT4 is always preinstalled
Order example KM1 T L C R R R D S E
Type
KR 1KM 1KX 1
KR1KM1KX1
Type
ControllerController + Timer
-T
Power supply
24 V100...240 V
LH
Inputs
TC + RTD + mA + V + mVTC + NTC + PTC + mA + V + mV
CE
OUT1
RelaySSR
RO
OUT2
RelaySSRWithout OUT2
RO-
OUT3
RelaySSRWithout OUT3
RO -
OUT4 (programmable*)
SSR, transmitter supply or floating input D
Interface
RS 485Without RS 485
S-
Connection block
Plug-in type incl. female connectorPlug-in without female connectorFix screw terminals
EN-
Typ KM 1
164
Technical data K 85
Control characteristics 2-point (on / off), 3-point (neutral zone), PID, dual PID
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0.5 % full scale + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
Resistance thermometerJ Pt100 / 3-wire -50...850 °C ±0.5 % full scale + 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ Type RJ Type TJ 0...50 mV, 0(12)...60 mV
0...1000 °C ±0.5 % full scale + 1 digit0...1370 °C ±0.5 % full scale + 1 digit0...1760 °C ±1 % full scale + 1 digit0...1760 °C ±0.5 % full scale + 1 digit0...400 °C ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
OutputsOutput OUT1J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC10 VDC, 20 mA
Output OUT2J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC10 VDC, 20 mA
Output OUT3J Relay (100 000 cycles)J SSR drive
SPST, 5 A / 2 A / 250 VAC10 VDC, 20 mA
DisplayJ 7-segment LEDJ Supplementary display
Single-row4-digit, red, 12 mm Drift indicator actual and setpoint value
ResolutionJ TemperatureJ Current / voltage
1 °C or 0.1 °C over the range -199.9...999.9 °CFreely scalable, adjustable decimal point
Temperature units °C, °FPower supply 24 VAC / DC ±10 %, 50 / 60 Hz
100...240 VAC ±10 %, 50 / 60 Hz
K 85
Housing
Degree of protection (front) IP40
Connections Screw terminal connection
Dimensions (W x H x D) 70 x 84 x 60 mm
Configuration
Parameter configuration input TTL 5-pin
Control input 2 floating inputs
Transmitter supply 10 VDC / 20 mA
COM interface Serial RS 485 (ModBus)
Timer 4 functions
Programmer 4 groups, 8 segments
165
Order example K85 T L C R R R S D
Model
ControllerController + TimerController + Timer + Programmer
-TP
Power supply
24 V100...240 V
LH
Measuring inputs
TC + Pt100 + mVTC + PTC + NTC + mVNorm signal mANorm signal V
CEIV
OUT1
RelaySSR
RO
OUT2
RelaySSRWithout OUT2
RO-
OUT3
RelaySSRWithout OUT3
RO-
Interface
RS 485 Without interface
S-
Control input
Floating inputWithout control input
D-
Type K 85
166
Technical data K 30
Control characteristics 2-point (on / off), 3-point (neutral zone), PID, dual PID
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0.5 % full scale + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
Resistance thermometerJ Pt100 / 3-wire -50...850 °C ±0.5 % full scale+ 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ Type RJ Type TJ 0...50 mV, 0(12)...60 mV
0...1000 °C ±0.5 % full scale + 1 digit0...1370 °C ±0.5 % full scale + 1 digit0...1760 °C ±1 % full scale + 1 digit0...1760 °C ±0.5 % full scale + 1 digit0...400 °C ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale+ 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
OutputsOutput OUT1J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC10 VDC, 20 mA
Output OUT2J Relay (100 000 cycles)J SSR drive
SPDT, 8 A / 3 A / 250 VAC10 VDC, 20 mA
Output OUT3J Relay (100 000 cycles)J SSR drive
SPST, 8 A / 3 A / 250 VAC10 VDC, 20 mA
Output OUT4J Relay (100 000 cycles)J SSR drive
SPST, 8 A / 3 A / 250 VAC10 VDC, 20 mA
Display WithoutResolutionJ TemperatureJ Current / voltage
1 °C or 0.1 °C over the range -199.9...999.9 °CFreely scalable, adjustable decimal point
Temperature units °C, °FPower supply 24 VAC / DC ±10 %, 50 / 60 Hz
100...240 VAC ±10 %, 50 / 60 Hz
K 30
Housing
Degree of protection (front) IP40
Connections Screw terminal connection
Dimensions (W x H x D) 30 x 88 x 78 mm
Configuration
Parameter configuration input TTL 5-pin
Control input 2 floating inputs
Transmitter supply 12 VDC / 20 mA
COM interface Serial RS 485 (ModBus)
Timer 4 functions
Programmer 4 groups, 8 segments
167
Order example K30 T L C R R R R S
Model
ControllerController + TimerController + Timer + Programmer
-TP
Power supply
24 V100...240 V
LH
Measuring inputs
TC + Pt100 + mVTC + PTC + NTC + mVNorm signal mANorm signal V
CEIV
OUT1
RelaySSR
RO
OUT2
RelaySSRWithout OUT2
RO-
OUT3
RelaySSRWithout OUT3
RO-
OUT4
RelaySSRWithout OUT4
RO-
Interface
RS 485 + floating inputWithout interface / Control input
S-
Connection block
Plug-in type incl. female connectorPlug-in without female connectorFix screw terminals
EN-
Type K 30
168
KR 3, KM 3 and KX 3
Technical data KR 3 KM 3 KX 3
Control characteristics 2-point (on / off), 3-point (neutral zone), PID, dual PID, 3-point incremental
Inputs
SemiconductorJ PTC KTY 81-121J NTC 103-AT2
-50...150 °C ±0.5 % full scale + 1 digit-50...109 °C ±0.5 % full scale + 1 digit
Resistance thermometerJ Pt100 / 3-wireJ Pt1000 / 2-wire
-200...850 °C ±0.5 % full scale + 1 digit-200...850 °C ±0.5 % full scale + 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ Type RJ Type TJ 0...50 mV, 0(12)...60 mV
-50...1000 °C ±0.5 % full scale + 1 digit-50...1370 °C ±0.5 % full scale + 1 digit-50...1760 °C ±1 % full scale + 1 digit-50...1760 °C ±0.5 % full scale + 1 digit-70...400 °C ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0.5 % full scale + 1 digit-1999...9999 ±0.5 % full scale + 1 digit
Outputs
Output OUT1J Relay (100 000 cycles)J SSR driveJ Analogue norm signal
SPDT, 4 A / 2 A / 250 VAC12 VDC, 15 mA0(4)...20 mA / 0(2)...10 VDC
SPST, 4 A / 2 A / 250 VAC12 VDC, 15 mA0(4)...20 mA / 0(2)...10 VDC
Output OUT2J Relay (100 000 cycles)J SSR drive
SPST, 2 A / 1 A / 250 VAC12 VDC, 15 mA
Output OUT3J Relay (100 000 cycles)J SSR drive
SPST, 2 A / 1 A / 250 VAC12 VDC, 15 mA
Output OUT4J SSR drive 12 VDC, 20 mA
DisplayJ 7-segment LEDJ Supplementary display
Double-row4-digit, red / green / orange, 15.5 mm Setpoint value indicator, green, 7 mm
Double-row and bargraph4-digit, red / green / orange, 15.5 mm Setpoint value indicator, green, 10 mm
ResolutionJ TemperatureJ Current / voltage
1 °C or 0.1 °C over the range -199.9...999.9 °CFreely scalable, adjustable decimal point
Temperature units °C, °F
Power supply 24 VAC / DC ±10 %, 50 / 60 Hz100...240 VAC ±10 %, 50 / 60 Hz
Housing KR 3 KM 3 KX 3
Degree of protection (Front)
IP65
Connections Screw terminal connection (fix), screw terminal connection (flex)
Dimensions (W x H x D)
75 x 33 x 78 mm
48 x 48 x 63 mm
48 x 96 x 76 mm
Configuration KR 3 KM 3 KX 3
Parameter configuration input TTL 5-pin
Control input 1 or 2 floating input
Transmitter supply 12 VDC / 20 mA
Programmer 4 groups, 8 segments
Timer 5 functions
COM interface Serial RS 485 (ModBus)
Other Dynamic display, Eco-Mode
169
* OUT4 is always preinstalled** 3-point incremental output relay always OUT2 + OUT3
Order example KM3 T L C R R R D S ETypeKR 3KM 3KX 3
KR3KM3KX3
TypeControllerController + TimerController + Timer + Programmer
-TP
Power supply24 V100...240 V
LH
InputsTC + mV + RTD + mA + VTC + mV + NTC + PTC + mA + V
CE
OUT1RelaySSRNorm signal mA + V
ROI
OUT2RelaySSR3-point incremental output relay**Without OUT2
ROM-
OUT3RelaySSR3-point incremental output relay**Without OUT3
ROM-
OUT4 (programmierbar*)
SSR, transmitter supply or floating input DInterfaceRS 485Without RS 485
S-
Connection block
Plug-in type incl. female connectorPlug-in without female connectorFix screw terminals
EN-
Typ KM 3
170
Overview series CON
: Optional available
CON-Basic CON-Solid
E 51 A W 09 TCPDE M TLZ 35 R 38 TLK 96 S
Dimensions 65 x 33 x 50 75 x 122 x 34 48 x 48 107 70 x 84 x 60 75 x 33 x 64 96 x 96 x 73
Display Single-row Single-row Analogue Single-row Single-row Single-row
Outputs
Relay (max.) 1 1 1 2 2 2
SSR drive
Analogue output
Control characteristics
2-point (on / off) ü ü ü ü ü ü
3-point (neutral zone)
PID ü ü
Dual PID
3-point incremental
Inputs
Semiconductor ü ü ü
Thermocouple ü ü ü
Resistance thermometer ü
Norm signals
Ausstattung
Configuration interface ü ü ü
Digital control input ü
Transmitter supply
Serial RS 485 interface
Timer
Programmer
Sensitive-touch-keys
Converter input
Power supply
12 VAC / DC ü ü
24 VAC / DC ü
115 VAC / 230 VAC ü ü ü
171
CON-Premium
TLK 72 KR 1 KM 1 KX 1 K 85 K 30 KR 3 KM 3 KX 3
72 x 72 x 98 75 x 33 x 75 48 x 48 x 62 48 x 96 x 76 70 x 84 x 60 30 x 88 x 78 75 x 33 x 75 48 x 48 x 62 48 x 96 x 76
Single-row Double-row Double-row Double-row Single-row Blind Zweizeilig Double-row Double-row
3 3 3 4 3
ü ü
ü ü ü ü
ü ü ü ü
ü ü ü ü
ü ü ü ü
ü ü
ü ü ü ü
ü ü
ü ü
On request
ü ü ü ü
172
Technical data TSIA 2000 TSIA 20
Inputs
Resistance thermometerJ Pt100 / 3-wireJ Pt1000 / 2-wire
-200...850 °C ±0.3 % full scale + 1 digit-50...850 °C ±0.3 % full scale + 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ Type TJ Type NJ 0...50 mV, 0(12)...60 mV
-170...950 °C ±0.3 % full scale + 1 digit-270...1350 °C ±0.3 % full scale + 1 digit-50...1750 °C ±0.5 % full scale + 1 digit-270...400 °C ±0.3 % full scale + 1 digit-270...1350 °C ±0.3 % full scale + 1 digit-1999...9999 ±0.3 % full scale + 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0.2 % full scale + 1 digit-1999...9999 ±0.2 % full scale + 1 digit
OutputsOutput OUT1J SSR driveJ Standardised analogue signal 0(4)...20 mA, 0...10 V
28 VDC / 1 A
Output OUT2J SSR drive 28 VDC / 1 A
DisplayJ 7-segment LED
Double-row4-digit, red, 13 mm
Double-row4-digit, red, 10 mm
ResolutionJ TemperatureJ Current / voltage
1 °C or 0.1 °C over the range -50.0...999.9 °CFreely scalable, adjustable decimal point
1 °C or 0.1 °C over the range -50.0...999.9 °CFreely scalable, adjustable decimal point
Temperature units °C, °F °C, °FPower supply 12 VAC / DC ±5 %, 50 / 60 Hz
24 VAC ±5 %, 50 / 60 Hz115 VAC ±5 %, 50 / 60 Hz230 VAC ±5 %, 50 / 60 Hz
9...28 VDC ±10 % (no galvanic isolation)
TSIA 2000 and TSIA 20
Electronic indicators, series IND
173
Order example TSIA20 G
Power supply
9...28V G
Order example TSIA2000 F CD
Power supply
12 V24 VDC24 VAC115 V230 V
FYACD
OUT1*
0(4)...20 mA (DC)0...10 V (DC)0(4)...20 mA (AC)0...10 V (AC)Kein OUT1
CDVDCAVA-
Type TSIA 2000
Type TSIA 20
Housing TSIA 2000 TSIA 20
Degree of protection (Front) IP65 IP54
Connections Screw terminal connection Screw terminal connection
Dimensions (W x H x D) 96 x 48 x 115 mm 48 x 24 x 65 mm
Configuration TSIA 2000 TSIA 20
Parameter configuration input 24 VDC / 22 mA
COM interface Serial RS 485 (EB-protocol) Serial RS 485 (EB-protocol)
* Include supply voltage
174
Technical data TSIA 2002
Inputs
Resistance thermometerJ Pt100 / 3-wireJ Pt1000 / 2-wire
-200...850 °C ±0.3 % full scale + 1 digit-50...850 °C ±0.3 % full scale + 1 digit
ThermocoupleJ Type JJ Type KJ Type SJ Type TJ Type NJ 0...50 mV, 0(12)...60 mV
-170...950 °C ±0.3 % full scale + 1 digit-270...1350 °C ±0.3 % full scale + 1 digit-50...1750 °C ±0.5 % full scale + 1 digit-270...400 °C ±0.3 % full scale + 1 digit-270...1350 °C ±0.3 % full scale + 1 digit-1999...9999 ±0.3 % full scale + 1 digit
Standardised signal inputsJ 0(4)...20 mAJ 0(1)...5 V, 0(2)...10 V
-1999...9999 ±0.2 % full scale + 1 digit-1999...9999 ±0.2 % full scale + 1 digit
OutputsOutput OUT1J Relay (100 000 cycles)J SSR driveJ Standardised analogue signal
SPST, 5 A / 2 A / 250 VAC6 VDC, 15 mA0(4)...20 mA, 0...10 V
Output OUT2J Relay (100 000 cycles)J SSR drive
SPDT, 10 A / 4 A / 250 VAC6 VDC, 15 mA
Output OUT3J Relay (100 000 cycles)J SSR drive
SPDT, 1 A / 0,6 A / 40 VAC14 VDC, 15 mA
DisplayJ 7-segment LED
Single-row4-digit, red, 13 mm
ResolutionJ TemperatureJ Current / voltage
1 °C or 0.1 °C over the range -50.0...999.9 °CFreely scalable, adjustable decimal point
Temperature units °C, °FPower supply 12 VDC ±5 %
24 VAC / DC ±5 %, 50 / 60 Hz115 VAC ±5 %, 50 / 60 Hz230 VAC ±5 %, 50 / 60 Hz
TSIA 2002
175
Order example TSIA2002 F CD R RD
Power supply
12 V24 VDC24 VAC115 V230 V
FYACD
OUT1*
RelaySSR0(4)...20 mA (DC)0...10 V (DC)0(4)...20 mA (AC)0...10 V (AC)Without OUT1
ROCDVDCAVA-
OUT2
0(4)...20 mA (DC)0...10 V (DC)0(4)...20 mA (AC)
RO-
OUT3*
Relay (DC)SSR (DC)Relay (AC)SSR (AC)0(4)...20 mA (DC)0...10 V (DC)0(4)...20 mA (AC)0...10 V (AC)Without OUT3
RDODRAOACDVDCAVA-
* Include supply voltage
Type TSIA 2002
Housing
Degree of protection (front) IP65
Connections Screw terminal connection
Dimensions (W x H x D) 96 x 48 x 115 mm
Configuration
Transmitter supply 24 VDC / 22 mA
COM interface Serial RS 485 (EB-Protokoll)
176
177
DIGITAL THERMOMETERS
J Series DiTemp
J Series SolarTemp
DS_Digital_thermometers 05/2014
Including products with:
178
The SolarTemp and DiTemp series offers remarkable features and performance characteristics for local indication of temperature. Consistent accuracy and freedom from maintenance for the entire lifespan of the product is thus combined in one instrument.
The extremely low energy consumption of electronic digital thermometers from SIKA makes them a completely new kind of instrument. The DiTemp has a lithium battery as energy source that has a service life of around 10 years.
The SolarTemp uses a solar cell integrated into the display module as energy source and the instrument works reliably in artificial light levels of 50 lux or more. Since the statutory minimum light level for industrial operations is 100 lux, the SIKA SolarTemp can be used practically anywhere.
Without external power supply
179
Mechanical thermometers for local indication of temperature are already available for the industrial sector. But although they manage without an external power supply, they have only an analogue display. These are filled with mercury or gas or supplied in the form of bimetal dial thermometers.
These instruments function without measuring liquids such as mercury, which also poses a risk to the health, so potential environmental pollution is effectively removed both during production and at disposal.Remote-working thermometers are also available. These are considerably easier to install since routing a flexible electrical cable presents few problems compared to a rigid capillary tube. The sensor is connected to the display unit by a plug connector. A front pane of hardened glass with FDA approval is available for food applications.
Advantages • No maintenance whatsoever required over the lifespan of the product through the use of a photovoltaic cell for artificial light
from 50 lux or a lithium battery with aservice life of approx. 10 years
• Because these instruments do not have a mechanical measuring mechanism, they are extremely vibration-proof and wear-free
• Optionally available with analogue output or freely programmable switching contacts
• The integrated transducer saves space as well as acquisition and installation costs
• Easy to read display, both analogue and digital
• Intrinsically safe to RL 94/9/EG (ATEX) for zone 1 / 21
Wearfree and environmentally compatible
The display unitThe DiTemp and SolarTemp have an easily readable LCD display. Two different types of display are available.
The basic reasoning behind the design of the dual display unit was to give it the appearance of a traditional dial instrument. We achieved this with a circular arrangement of LCD elements. This quasi-analogue format enables you to interpret the reading as instantly as a conventional dial instrument. However, a 4-digit, 7-segment display is additionally incorporated for times when you want to know the exact temperature.
The measuring principleDigital thermometers of the DiTemp and SolarTemp series work with a discrete-time process with one measurement cycle taking 3 seconds. The user can therefore read off the current temperature even in passing. A flashing activity symbol on the display indicates correct functioning of the instrument during the measurement cycle.
Electronic and accurate - digital and analogue
181
Mechanical constructionInstruments of the DiTemp and SolarTemp and have a robust mechanical assembly and are designed for both industrial applications and use in harsh environmental conditions. The IP65 protection level ensures these requirements are met. The immunity to electromagnetic interference satisfies the requirements of the current industrial standards.
Continuous self-testAfter switch-on, the instrument performs an internal selftest that includes a check of the connected sensor. Automatic diagnostic routines continuously monitor the sensor signal and a broken sensor is indicated via the display unit. The microprocessor constantly tests the sensor signal for plausibility. In the event of a fault, the results are indicated on the display as an error code.
Integrated measurement transducerIntegration of the measurement transducer into the local display unit means the space requirement is substantially reduced along with acquisition and installation costs, since a complete measuring point is saved. The measurement transducer system is independent of the local display unit, providing you with a redundant measuring system. The instrument is supplied via the transmitter, so there is no load on the battery or solar cell unless the current loop fails. This means the local display is both reliable and independent.
Freely programmable switching contactThe absence of mechanical contacts makes the thermometer fail-safe and prevents unwanted switching operations through vibration, for example. In addition to the programmable alarm contact, the instrument has a signalling contact that indicates all faulty operating states such as broken sensor or battery charge level. The contacts are designed as normally open contacts. Programming is performed without touching the instrument and is menu assisted. All operating states are monitored by the electronics. In contrast to mechanical instruments, the user has the benefit of a measuring system that is significantly more reliable und stable over the long term.
182
Technical datas
Measuring input
Pt1000 / 2-wire
Display Single-row , 3½ digit 7 segment LCD, 21 mm high
Resolution 0.1 °C in range -40.0...199.9 °C
Cycle time 6 sec.
Accuracy ±1 % full scale ±1 digit
Housing Bajonet caseStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Degree of protection
IP65 (frontside)
Dimensions Ø 100 mm, depth 20 mm
Power supply Button cell, 4 years service life
Type LCK-03
LCK
Series DiTemp
183
Order example 9A2 42 100 1 0 0 1 0 0 0
Connection type
Immersion tube routed to the rear (axial) LCK-02Immersion tube 90° LCK-03Immersion tube universally adjustable LCK-07
9A29A39A7
Range*
-40...200 °C 42
Immersion tube length* L1 / Nominal length L = L1 + 35
100 mm 135 mm160 mm 195 mm250 mm 285 mm400 mm 435 mm
100160250400
Immersion tube type*
Plain without thread ACoupling AK
19
Thread type*
None Coupling with male thread AKaCoupling with female thread AKi
023
Thread type dg*
NoneG¼G½G¾M20 x 1.5M27 x 2
0L2379
Material of tube* / Material clamp coupling*
Stainless steel 1.4571 no couplingStainless steel 1.4571 Stainless steel 1.4571
13
Immersion tube diameter
8 mm 0
Connecting cable*
None 0
Special features*
NoneShatter-proof plastic front screen (FDA version)
02
* Other specifications are available on request
Order code
184
Technical data
Measuring input
Pt1000 / 2-wire
Display Single-row, 3½ digit 7 segment LCD, 21 mm high
Resolution 0.1 °C in range -40.0...199.9 °C, else 1 °C
Cycle time 3 sec.
Accuracy ±1 % full scale ±1 digit
Housing Bajonet caseStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Degree of protection
IP65 (frontside)
Dimensions Ø 100 mm, depth 45 mm
Power supply Lithium battery, 10 years service life
Type ICB-02
ICB
Options
Analog output
• 4…20 mA / 2-wire
• 15-26 VDC loop power supply
• Pre-programmed to client specifications, error signals as per NAMUR NE43
• M12 plug including suitable connection socket
Alarm output
• Freely programmable switch point and hysteresis
• 15-26 VDC power supply
• 2 x NO contacts, fail-safe mode
• Semi-conductor relay output 24 VAC / DC 100 mA
• M12 plug including suitable connection socket
185
Order example 9E1 48 100 1 0 0 1 0 0 0
Connection type:
Immersion tube routed downwards (vertical) ICB-01Immersion tube routed to the rear (axial) ICB-02Immersion tube universally adjustable ICB-07M12 socket at bottom, with wall holder ICB-10M12 socket at bottom, mounting flange at rear ICB-20M12 socket at bottom, mounting flange at front ICB-30
9E19E29E39F09G09H0
Range*
-40...80 °C0...120 °C0...200 °C0...300 °C
48122030
Immersion tube length* L1 / Nominal length L = L1 + 35
100 mm 135 mm 160 mm 195 mm250 mm 285 mm 400 mm 435 mm
100160250400
Immersion tube type*
Plain without thread ACoupling AK
19
Thread type*
None Coupling with male thread AKaCoupling with female thread AKi
023
Thread type dg*
NoneG¼G½G¾M20 x 1.5M27 x 2
0L2379
Material of tube* / Material clamp coupling*
Stainless steel 1.4571 no couplingStainless steel 1.4571 Stainless steel 1.4571
13
Immersion tube diameter
8 mm6 mm
01
Connecting cable*
NoneCable length 1 m**Cable length 3 m**Cable length 5 m**Cable length 10 m**
0135A
Special features*
None4-20 mA analog output (pre-programmed to display rangealarm output (freely programmable in display range)shatter-proof plastic front screen (FDA version)
0352
* Other specifications are available on request ** ICB-10, ICB-20, ICB-30
Order code
186
DT3
Technical data
Measuring input
Pt1000 / 2-wire
Display Single-row, 3½ digit 7 segment LCD, 14 mm high, programmable bar graph 17 divisions
Resolution 0.1 °C in range -40.0...199.9 °C, else 1 °C
Cycle time 3 sec.
Accuracy ±1 % full scale ±1 digit
Housing Bajonet caseStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Protection level IP65 (frontside)
Dimensions Ø 80 mm, depth 45 mm
Power supply Lithium battery, 10 years service life
Type DT3-01
Options
Analog output
• 4…20 mA / 2-wire
• 15-26 VDC loop power supply
• Pre-programmed to client specifications, error signals as per NAMUR NE43
• M12 plug including suitable connection socket
Alarm output
• Freely programmable switch point and hysteresis
• 15-26 VDC power supply
• 2 x NO contacts, fail-safe mode
• Semi-conductor relay output 24 VAC / DC 100 mA
• M12 plug including suitable connection socket
187
Order code
Order example 961 48 100 1 0 0 1 0 0 0
Connection type
Immersion tube routed downwards (vertical) DT3-01Immersion tube routed to the rear (axial) DT3-02Immersion tube universally adjustable DT3-07M12 socket at bottom, with wall holder DT3-10M12 socket at bottom, mounting flange at rear DT3-20M12 socket at bottom, mounting flange at front DT3-30
961962967970980990
Range*
-40...80 °C0...120 °C0...200 °C0...300 °C
48122030
Immersion tube length* L1 / Nominal length L = L1 + 35
100 mm 135 mm 160 mm 195 mm250 mm 285 mm 400 mm 435 mm
100160250400
Immersion tube type*
Plain without thread ACoupling AK
19
Thread type*
None Coupling with male thread AKaCoupling with female thread AKi
023
Thread type dg*
NoneG¼G½G¾M20 x 1.5M27 x 2
0L2379
Material of tube* / Material clamp coupling*
Stainless steel 1.4571 no couplingStainless steel 1.4571 Stainless steel 1.4571
13
Immersion tube diameter
8 mm6 mm
01
Connecting cable*
NoneCable length 1 m**Cable length 3 m**Cable length 5 m**Cable length 10 m**
0135A
Special features*
None4-20 mA analog output (pre-programmed to display rangeAlarm output (freely programmable in display range)Shatter-proof plastic front screen (FDA version)
0352
* Other specifications are available on request ** DT3-10, DT3-20, DT3-30
188
901-Ex - 930-Ex
Technical Data
Measuring input
Pt1000 / 2-wire
Display Single-row, 4 digit 7 segment LCD, 11 mmhigh, programmable bar graph 61 divisions
Resolution 0.1 °C in range -40.0...199.9 °C, else 1 °C
Cycle time 3 sec.
Accuracy ±1 % full scale ±1 digit
Housing Bajonet caseStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Degree of Protection
IP65 (frontside)
Dimensions Ø 80 mm, depth 45 mm
Power supply Lithium battery, 10 years service life
Type 901-EX
Options
Analog output
• 4…20 mA / 2-wire
• 15-26 VDC loop power supply
• Pre-programmed to client specifications, error signals as per NAMUR NE43
• Angle plug including suitable connection socket
Alarm output
• Freely programmable switch point and hysteresis
• 15-26 VDC power supply
• 2 x NO contacts, fail-safe mode
• Semi-conductor relay output 24 VAC / DC 100 mA
• Angle plug including suitable connection socket
189
Order code
Order example 901 48 100 1 0 0 1 0 0 1
Connection type
Immersion tube routed downwards (vertical) 901-EXImmersion tube routed to the rear (axial) 902-EXImmersion tube universally adjustable 907-EXM12 socket at bottom, with wall holder 910-EXM12 socket at bottom, mounting flange at rear 920-EXM12 socket at bottom, mounting flange at front 930-EX
901902907910920930
Range*
-40...80 °C0...120 °C0...200 °C0...300 °C
48122030
Immersion tube length* L1 / Nominal length L = L1 + 35
100 mm 135 mm 160 mm 195 mm250 mm 285 mm 400 mm 435 mm
100160250400
Immersion tube type*
Plain without thread ACoupling AK
19
Thread type*
None Coupling with male thread AKaCoupling with female thread AKi
023
Thread type dg*
NoneG¼G½G¾M20 x 1.5M27 x 2
0L2379
Material of tube* / Material clamp coupling*
Stainless steel 1.4571 no couplingStainless steel 1.4571 Stainless steel 1.4571
13
Immersion tube diameter
8 mm6 mm
01
Connecting cable*
NoneCable length 1 m**Cable length 3 m**Cable length 5 m**Cable length 10 m**
0135A
Special features*
Hazardous area version PTB 05 ATEX 2036 Eex ia IIC T34-20 mA analog output and hazardous area version (pre-programmed to display range)Alarm output and hazardous area version (freely programmable in display range)
146
* Other specifications are available on request ** 910-EX, 920-EX, 930-EX
190
Series SolarTemp
Technical data
Measuring input
Pt1000 / 2-wire
Display Single-row, 3½ digit 7 segment LCD, 21 mm high
Resolution 0.1 °C in range -40.0...199.9 °C
Cycle time 3 sec.
Accuracy ±1 % full scale ±1 digit
Housing Bajonet caseStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Degree of protection
IP65 (frontside)
Dimensions Ø 100 mm, depth 20 mm
Power supply Solar cell, 80 lux
Type LC-03
LC
191
Order example 8A2 42 100 1 0 0 1 0 0 0
Connection type
Immersion tube routed to the rear (axial) LC-02Immersion tube 90° LC-03Immersion tube universally adjustable LC-07
8A28A38A7
Range*
-40...200 °C 42
Immersion tube length* L1 / Nominal length L = L1 + 35
100 mm 135 mm160 mm 195 mm250 mm 285 mm400 mm 435 mm
100160250400
Immersion tube type*
Plain without thread ACoupling AK
19
Thread type*
None Coupling with male thread AKaCoupling with female thread AKi
023
Thread type dg*
NoneG¼G½G¾M20 x 1.5M27 x 2
0L2379
Material of tube* / Material clamp coupling*
Stainless steel 1.4571 no couplingStainless steel 1.4571 Stainless steel 1.4571
13
Immersion tube diameter
8 mm 0
Connecting cable*
None 0
Special features*
NoneShatter-proof plastic front screen (FDA version)
02
* Other specifications are available on request
Order code
192
IC
Technical data
Measuring input
Pt1000 / 2-wire
Display Single-row, 3½ digit 7 segment LCD, 21 mm high
Resolution 0.1 °C in range -40.0...199.9 °C, else 1 °C
Cycle time 3 sec.
Accuracy ±1 % full scale ±1 digit
Housing Bajonet caseStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Degree of Protection
IP65 (frontside)
Dimensions Ø 100 mm, depth 45 mm
Power supply Solar cell, 80 lux
Type IC-10
Options
Analog output
• 4…20 mA / 2-wire
• 15-26 VDC loop power supply
• Pre-programmed to client specifications, error signals as per NAMUR NE43
• M12 plug including suitable connection socket
Alarm output
• Freely programmable switch point and hysteresis
• 15-26 VDC power supply
• 2 x NO contacts, fail-safe mode
• Semi-conductor relay output 24 VAC / DC 100 mA
• M12 plug including suitable connection socket
193
Order code
Order example 8E1 48 100 1 0 0 1 0 0 0
Connection type
Immersion tube routed downwards (vertical) IC-01Immersion tube routed to the rear (axial) IC-02Immersion tube universally adjustable IC-07M12 socket at bottom, with wall holder IC-10M12 socket at bottom, mounting flange at rear IC-20M12 socket at bottom, mounting flange at front IC-30
8E18E28E78F08G08H0
Range*
-40...80 °C0...120 °C0...200 °C0...300 °C
48122030
Immersion tube length* L1 / Nominal length L = L1 + 35
100 mm 135 mm 160 mm 195 mm250 mm 285 mm 400 mm 435 mm
100160250400
Immersion tube type*
Plain without thread ACoupling AK
19
Thread type*
None Coupling with male thread AKaCoupling with female thread AKi
023
Thread type dg*
NoneG¼G½G¾M20 x 1.5M27 x 2
0L2379
Material of tube* / Material clamp coupling*
Stainless steel 1.4571 no couplingStainless steel 1.4571 Stainless steel 1.4571
13
Immersion tube diameter
8 mm6 mm
01
Connecting cable*
NoneCable length 1 m**Cable length 3 m**Cable length 5 m**Cable length 10 m**
0135A
Special features*
None4-20 mA analog output (pre-programmed to display range)Alarm output (freely programmable in display range)Shatter-proof plastic front screen (FDA version)
0352
* Other specifications are available on request ** IC-10, IC-20, IC-30
194
850
Technical data
Measuring input
Pt1000 / 2-wire
Display Single-row, 4 digit 7 segment LCD,25 mm high
Resolution 0.1 °C in range 0...650 °C
Cycle time 3 sec.
Accuracy ±0.2 % full scale ±1 digit
Housing Molded housingStainless steel 1.4301 with polished front frame Glass or plastic front screenAmbient temperature -20…60 °C
Degree of protection
IP65 (frontside)
Dimensions 144 mm x 144 mm, depth 30 mm
Power supply Solar cell, 50 lux
Type 850
Options
Analog output
• 4…20 mA / 2-wire
• 15-26 VDC loop power supply
• Error signals as per NAMUR NE43
• M12 plug including suitable connection socket
195
Order code
Order example 850 65 P54 1
Type
SolarTemp 850 850
Range*
0...650 °C 65
Measurement systems
Temperaturmessung für Anzeige (1 x Pt1000)Temperaturmessung für Anzeige und Transmitter (2 x Pt1000)
P54P53
Special features*
NoneAnalogue output 4...20 mA (pre-programmed to display range) 0...300 °CAnalogue output 4...20 mA (pre-programmed to display range) 0...600 °C
1330360
* Other specifications are available on request
196
Overview Connection types
Solid tube at bottom
Solid tube, 90°
M12 socket at bottom,wall holder
M12 socket at bottom,mounting flange at rear
M12 socket at bottom,mounting flange at front
Solid tube to the rear
Solid tube routed to the rear
Universal adjustable tube,with optional output*
Universal adjustable tube
DT3 / 901 - 930 housing, Ø80 mm x 45 mm
LCK / LC housing, Ø100 mm x 20 mm
Nominal length L = L1 + 35 mm
Nominal length L = L1 + 35 mm
Nom
inal
leng
th L
= L
1 +
35 m
m
Nom
inal
leng
th L
= L
1 +
35 m
m
Imm
ersi
on tu
be le
ngth
L1
Nom
inal
leng
th L
= L
1 +
35 m
m
Nom
inal
leng
th L
= L
1 +
35 m
m
197
Solid tube at bottom
M12 socket at bottom,wall holder
Front Side
M12 socket at bottom,mounting flange at rear
M12 socket at bottom,mounting flange at front
Solid tube to the rear,with optional output*
Universal adjustable tube
850 housing, 144 mm x 144 mm, depth 30 mm
ICB / IC housing, Ø100 mm x 45 mm
Nominal length L = L1 + 35 mm
Nom
inal
leng
th L
= L
1 +
35 m
m
Nom
inal
leng
th L
= L
1 +
35 m
m
130
155
6 x
Ø6,
2
35
130
155
6 x
Ø6,
2
35
198
Basic Solid Premium
LCK-02 LCK-03 LCK-07 ICB-01 ICB-02 ICB-07 ICB-10 ICB-20 ICB-30 DT3-01 DT3-02 DT3-07 DT3-10 DT3-20 DT3-30 901 902 907 910 920 930
Housing Bajonet case, Ø 100 mm x 20 mm Bajonet case, Ø 100 mm x 45 mm Bajonet case, Ø 80 mm x 45 mm Bajonet case, Ø80 mm x 45 mm
Power supply Button cell, 4 years service life Lithium battery, 10 years service life Lithium battery, 10 years service life Lithium battery, 10 years service life
LCD Display 3½ digit, 21 mm high 3½ digit, 21 mm high 3½ digit, 14 mm high, bar graph 17 divisions 4 digit, 11 mm high, bar graph 61 divisions
Temperature range -40...199.9 °C -40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
-40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
-40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
Cycle time 6 sec 3 sec 3 sec 3 sec
Accuracy ±1 % full scale ±1 % full scale ±0.2 % full scale ±1 % full scale ±0.2 % full scale ±1 % full scale ±0.2 % full scale
Connection Solid tubeat bottom
Solid tubeat bottom, 90°
Universal tubeat bottom
Solid tube at bottom
Solid tube at bottom
Universal tubeat bottom
M12 socket at bottom Solid tubeat bottom
Solid tubeat bottom
Universal tubeat bottom
M12 socket at bottom Solid tube at bottom
Solid tube at bottom
Universal tubeat bottom
M12 socket at bottom
Mounting Direct Direct Wallholder
At rear At front Direct Wall holder
At rear At front Direct Wall holder
At rear At front
Immersion tube-Ø 8 mm 8 mm6 mm
8mm6mm
8 mm6 mm
Length L1 100 mm 100 mm 100 mm 100 mm
Neck tube Ø 14 x 35 mm Ø 25 x 35 mm
Ø14 x 35 mm Ø25 x 35 mm
Ø14 x 35 mm Ø25 x 35 mm
Analogue output
Alarm output
Hazardous area version
Overview DiTemp
199
Basic Solid Premium
LCK-02 LCK-03 LCK-07 ICB-01 ICB-02 ICB-07 ICB-10 ICB-20 ICB-30 DT3-01 DT3-02 DT3-07 DT3-10 DT3-20 DT3-30 901 902 907 910 920 930
Housing Bajonet case, Ø100 mm x 20 mm Bajonet case, Ø100 mm x 45 mm Bajonet case, Ø 80 mm x 45 mm Bajonet case, Ø 80 mm x 45 mm
Power supply Button cell, 4 years service life Lithium battery, 10 years service life Lithium battery, 10 years service life Lithium battery, 10 years service life
LCD Display 3½ digit, 21 mm high 3½ digit, 21 mm high 3½ digit, 14 mm high, bar graph 17 divisions 4 digit, 11 mm high, bar graph 61 divisions
Temperature range -40...199.9 °C -40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
-40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
-40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
Cycle time 6 sec 3 sec 3 sec 3 sec
Accuracy ±1 % full scale ±1 % full scale ±0.2 % full scale ±1 % full scale ±0.2 % full scale ±1 % full scale ±0.2 % full scale
Connection Solid tubeat bottom
Solid tubeat bottom, 90°
Universal tubeat bottom
Solid tube at bottom
Solid tube at bottom
Universal tubeat bottom
M12 socket at bottom Solid tubeat bottom
Solid tubeat bottom
Universal tubeat bottom
M12 socket at bottom Solid tube at bottom
Solid tube at bottom
Universal tubeat bottom
M12 socket at bottom
Mounting Direct Direct Wallholder
At rear At front Direct Wall holder
At rear At front Direct Wall holder
At rear At front
Immersion tube-Ø 8 mm 8 mm6 mm
8mm6mm
8 mm6 mm
Length L1 100 mm 100 mm 100 mm 100 mm
Neck tube Ø14 x 35 mm Ø25 x 35 mm
Ø 14 x 35 mm Ø 25 x 35 mm
Ø 14 x 35 mm Ø 25 x 35 mm
Analogue output
Alarm output
Hazardous area version
200
Overview SolarTemp
Basic Solid Solid Premium
LC-02 LC-03 LC-07 IC-01 IC-02 IC-07 IC-10 IC-20 IC-30 850
Housing Bajonet case, Ø 100 mm x 20 mm Bajonet case, Ø 100 mm x 45 mm Bajonet case, Ø100 mm x 45 mm Molded housing, 144 mm x 144 mm, depth 30 mm
Power supply Solar cell, 80 lux Solar cell, 80 lux Solar cell, 80 lux Solar cell, 50 lux
LCD Display 3½ digit, 21 mm high 3½ digit, 21 mm high 3½ digit, 21 mm high 4 digit, 25 mm high
Temperature range -40...199.9 °C -40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
-40...650 °C
Cycle time 3 sec 3 sec 3 sec 3 sec
Accuracy ±1 % full scale ±1 % full scale ±0.2 % full scale ±0.2 % full scale
Connection Solid tubeat bottom
Solid tubeat bottom, 90°
Universal tubeat bottom
Solid tubeat bottom
Solid tubeat bottom, 90°
Universal tubeat bottom
M12 socket at bottom M12 socket at bottom
Mounting Direct Direct Wall holder At rear At front Wall mounting
Immersion tube-Ø 8 mm 8 mm6 mm
Length L1 100 mm 100 mm
Neck tube Ø 14 x 35 mm Ø25 x 35 mm
Analogue output
Alarm output
Hazardous area version
201
Basic Solid Solid Premium
LC-02 LC-03 LC-07 IC-01 IC-02 IC-07 IC-10 IC-20 IC-30 850
Housing Bajonet case, Ø100 mm x 20 mm Bajonet case, Ø100 mm x 45 mm Bajonet case, Ø 100 mm x 45 mm Molded housing, 144 mm x 144 mm, depth 30 mm
Power supply Solar cell, 80 lux Solar cell, 80 lux Solar cell, 80 lux Solar cell, 50 lux
LCD Display 3½ digit, 21 mm high 3½ digit, 21 mm high 3½ digit, 21 mm high 4 digit, 25 mm high
Temperature range -40...199.9 °C -40...199.9 °C200...400 °C
-40...199.9 °C200...650 °C
-40...650 °C
Cycle time 3 sec 3 sec 3 sec 3 sec
Accuracy ±1 % full scale ±1 % full scale ±0.2 % full scale ±0.2 % full scale
Connection Solid tubeat bottom
Solid tubeat bottom, 90°
Universal tubeat bottom
Solid tubeat bottom
Solid tubeat bottom, 90°
Universal tubeat bottom
M12 socket at bottom M12 socket at bottom
Mounting Direct Direct Wall holder At rear At front Wall mounting
Immersion tube-Ø 8 mm 8 mm6 mm
Length L1 100 mm 100 mm
Neck tube Ø14 x 35 mm Ø 25 x 35 mm
Analogue output
Alarm output
Hazardous area version
202
KOMBITEMP®
TEMPERATURE SENSOR WITH LOCAL DISPLAY
J Head form B
J Head form J
J Cable socket, angle type
DS_KombiTemp 05/2014
Including products with:
204
Ideal for every application The combination of electrical sensor with a local display has many advantages:
• Temperature monitoring from two completely independent measuring systems.
• Significantly increased accuracy, because the joint measuring point makes it possible to compare the electrical temperature sensor directly with the „on site“ display and vice versa.
• The installation costs for the temperature measuring instruments decrease because only one measuring point needs to be installed for the electrical temperature sensor and the local temperature measurement.
• The use of SIKA KombiTemp® increases the operational safety of the monitored plants because faulty electrical temperature sensors or industrial thermometers are immediately detected.
• Glass inserts and electrical temperature sensors conform with DIN standards, and can be replaced, except for the models K 122, K 422, K 510, K 520, and K 522.
• Upon request both temperature units, °C and °F, can be printed on the housing label (double scale display).
Dual temperature control with only one measuring point!
-205-205
DescriptionThe SIKA KombiTemp® consists of:
1. A SIKA-industrial glass thermometer with the following properties:
• Shock proof
• Very good readability
• Very good long-term stability of the capillary accuracy
• The capillaries of the thermometer are produced and calibrated in accordance with DIN 16195
• The housing surface is protected against external influences by a thick anodised coating
2. At customer‘s request, an electrical temperature sensor in the same housing and immersion tube as the industrial thermometer:
• Temperature sensors in accordance with DIN or customised
• Any electrical connection options available
205
206
Type K 410
K 410 and K 420 for measuring ranges between -60 to 200 °C
Head form B
Technical data Type K 410 Type K 420Design Straight, clamp connection Straight, fixed thread connectionMeasuring range -60…40 °C
-30…50 °C0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 135 mm or 160 mm 63 mm, 100 mm or 160 mmElectrical connection Head form B (DIN 43729)Mechanical connection G½ A G½ A, G¾ A or M20 x 1.5Electrical temperature sensor
1x NiCr-Ni (type K) or 1x Fe-CuNi (type J),2x NiCr-Ni (type K) or 2x Fe-CuNi (type J)1x Pt100 / 3-wire, 2x Pt100 / 3-wire, 1x Pt1000 / 2-wire,
Option head transmitter 4…20 mA or 0...10 V for Pt100
Housing
• Die cast aluminiumlenght 150 mm / width 36 mm, silver-coloured anodised
Thermometer capillaries
• Special glass prismatic, approx. 6 mm diameterwith black burnt-in scale
Thermometer filling
• Red (-60...40 °C)
• Blue (-30...200 °C)
Immersion tube
• Diameter 12 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
207
Type K 510
K 510 and K 520 for measuring ranges between -60 to 200 °C
Technical data Type K 510 Type K 520Design 90° clamp connection 90° fixed thread connectionMeasuring range -60…40°C
-30…50 °C0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 135 mm or 160 mm 63 mm, 100 mm or 160 mmElectrical connection Head form B (DIN 43729)Mechanical connection G½ A G½ A or M20 x 1.5Electrical temperature sensor
1x Pt100 / 3-wire / class B1x Pt1000 / 2-wire / class B
Option head transmitter 4…20 mA or 0...10 V for Pt100
Housing
• Die cast aluminiumlenght 150 mm / width 36 mm, silver-coloured anodised
Thermometer capillaries
• Special glass, approx. 5.5 mm diameter with black burnt-in scale
Thermometer filling
• Red (-60...40 °C)
• Blue (-30...200 °C)
Immersion tube
• Diameter 12 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
208
Type K 610
K 610 and K 620 for measuring ranges between -60 to 200 °C
Technical data Type K 610 Type K 620Design 90° clamp connection 90° fixed thread connectionMeasuring range -60…40 °C
-30…50 °C0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 135 mm or 160 mm 63 mm, 100 mm or 160 mmElectrical connection Head form B (DIN 43729)Mechanical connection G½ A G½ A or M20 x 1.5Electrical temperature sensor
1 x NiCr-Ni (Type K) or 1 x Fe-CuNi (Type J), 2 x NiCr-Ni (Type K) or 2 x Fe-CuNi (Type J)1 x Pt100 / 3-wire, 2 x Pt100 / 3-wire,1 x Pt100 / 4-wire or 1 x Pt1000 / 2-wire (class B)
Option head transmitter 4…20 mA or 0...10 V for Pt100
Housing
• Die cast aluminiumlenght 150 mm / width 36 mm, silver-coloured anodised
Thermometer capillaries
• Special glass, approx. 5.5 mm diameter with black burnt-in scale
Thermometer filling
• Red (-60...40 °C)
• Blue (-30...200 °C)
Immersion tube
• Diameter 12 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
209
Type K 120
K 110 and K 120 for measuring ranges between -30 to 200 °C
Technical data Type K 110 Type K 120Design Traight, clamp connection Straight, fixed thread connectionMeasuring range -30…50 °C
0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 135 mm or 160 mm 63 mm, 100 mm or 160 mmElectrical connection Head form J, topMechanical connection G½ A G½ A or M20 x 1.5Electrical temperature sensor
1x Pt100 / 3-wire / class B1x Pt1000 / 2-wire / class B
Option head transmitter 4…20 mA for Pt100
Head form J
Housing
• Die cast aluminiumlength 110 mm / width 30 mm, silver-coloured anodised
Thermometer capillaries
• Special glass prismatic, approx. 6 mm diameter with black burnt-in scale
Thermometer filling
• Blue
Immersion tube
• Diameter 12 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
210
Type K 122
Technical data Type K 122Design Straight, fixed thread connectionMeasuring range -30…50 °C
0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 63 mm, 100 mm or 160 mmElectrical connection Cable socket, angle type DIN EN 175301-803Mechanical connection G½ A or M20 x 1.5Electrical temperature sensor 1x Pt100 / 3-wire / class B
1x Pt1000 / 2-wire / class B
K 122 for measuring ranges between -30 to 200 °C
Cable socket, angle type
Housing
• Die cast aluminiumlength 110 mm / width 30 mm, gold-coloured anodised
Thermometer capillaries
• Special glass prismatic, approx. 6 mm diameter with black burnt-in scale
Thermometer filling
• Blue
Immersion tube
• Diameter 10 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
211
Type K 422
K 422 for measuring ranges between -30 to 200 °C
Technical data Type K 422Design Straight, fixed thread connectionMeasuring range -30…50 °C
0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 63 mm, 100 mm or 160 mmElectrcal connection Cable socket, angle type DIN EN 175301-803
Mechanical connection G½ A or M20 x 1.5Electrical temperature sensor 1x Pt100 / 3-wire / class B
1x Pt1000 / 2-wire / class B
Housing
• Die cast aluminiumlength 150 mm / width 36 mm, gold-coloured anodised
Thermometer capillaries
• Special glass prismatic, approx. 6 mm diameter with black burnt-in scale
Thermometer filling
• Blue
Immersion tube
• Diameter 10 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
212
Type K 522
K 522 for measuring ranges between -30 to 200 °C
Technical data Type K 522Design 90° fixed thread connectionMeasuring range -30…50 °C
0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 63 mm, 100 mm or 160 mmElectrical connection Cable socket, angle type DIN EN 175301-803Mechanical connection G½ A or M20 x 1.5Electrical temperature sensor 1x Pt100 / 3-wire / class B
1x Pt1000 / 2-wire / class B
Housing
• Die cast aluminiumlength 150 mm / width 36 mm, gold-coloured anodised
Thermometer capillaries
• Special glass prismatic, approx. 6 mm diameter with black burnt-in scale
Thermometer filling
• Blue
Immersion tube
• Diameter 10 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
213
Type K 130
K 130 for measuring ranges between -30 to 200 °C
Technical data Type K 130
Design 90° fixed thread connection
Measuring range -30…50 °C0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
Immersion tube length 63 mm, 100 mm or 160 mm
Electrical connection Cable socket, angle type DIN EN 175301-803
Mechanical connection G½ A or M20 x 1.5
Electrical temperature sensor 1x Pt100 / 3-wire / class B1x Pt1000 / 2-wire / class B
Housing
• Die cast aluminiumlength 110 mm / width 30 mm, gold-coloured anodised
Thermometer capillaries
• Special glass prismatic, approx. 6 mm diameter with black burnt-in scale
Thermometer filling
• Blue
Immersion tube
• Diameter 12 x 1 mm
Immersion tube material
• Brass, up to PN 16 bar
• Stainless steel, up to PN 40 bar
214
Order code
Choose your KombiTemp®
Example: KombiTemp® K 110 with measuring range between 0...60 °C, immersion tube length 135 mm, G½ A connection, made of brass with electrical temperature sensor Pt1000 / 2-wire, without head transmitter and scaled in °C is due to order number: K1100613521700ATTENTION - you have to choose an option on every property to get the 14-character order number
Head form B Head form J Cable socket, angle type
Type K 410 K 420 K 510 K 520 K 610 K 620 K 110 K 120 K 122 K 422 K 522 K 130
Measuring range
-60…40°C-30…50 °C0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
64350610121620
64350610121620
64350610121620
64350610121620
64350610121620
64350610121620
350610121620
350610121620
350610121620
350610121620
350610121620
350610121620
Immersion tube length
63 mm100 mm135 mm160 mm
135 160
063 100
160 135 160
063 100
160 135 160
063 100
160 135 160
063 100
160
063 100
160
063 100
160
063 100
160
063 100
160
Mechanical connection
G½ AG¾ AM20 x 1.5
2 2 3 7
2 2
7
2 2
7
2 2
7
2
7
2
7
2
7
2
7
Immersion tube material
BrassStainless steel
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
Electrical temperature sensor
1x Pt100 / 3-wire2x Pt100 / 3-wire1x Pt100 / 4-wire1x Pt1000 / 2-wire1x NiCr-Ni (Type K)2x NiCr-Ni (Type K)1x Fe-CuNi (Type J) 2x Fe-CuNi (Type J)
1 4
7 2 5 3 6
1 4
7 2 5 3 6
1
7
1
7
1 4 8 7 2 5 3 6
1 4 8 7 2 5 3 6
1 4
7 2
3
1 4
7 2
3
1
7
1
7
1
7
1 4
7 2
3
Head transmitter
Without transmitterWith 4...20 mAWith 0...10 V
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2
0 1
0 1
0 0 0 0
Scale
only °C°C and °F
0 0 0 0 2
0 0 0 0 0 2
0 2
0 0 2
215
Head form B Head form J Cable socket, angle type
Type K 410 K 420 K 510 K 520 K 610 K 620 K 110 K 120 K 122 K 422 K 522 K 130
Measuring range
-60…40°C-30…50 °C0…60 °C0…100 °C0…120 °C0…160 °C0…200 °C
64350610121620
64350610121620
64350610121620
64350610121620
64350610121620
64350610121620
350610121620
350610121620
350610121620
350610121620
350610121620
350610121620
Immersion tube length
63 mm100 mm135 mm160 mm
135 160
063 100
160 135 160
063 100
160 135 160
063 100
160 135 160
063 100
160
063 100
160
063 100
160
063 100
160
063 100
160
Mechanical connection
G½ AG¾ AM20 x 1.5
2 2 3 7
2 2
7
2 2
7
2 2
7
2
7
2
7
2
7
2
7
Immersion tube material
BrassStainless steel
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
Electrical temperature sensor
1x Pt100 / 3-wire2x Pt100 / 3-wire1x Pt100 / 4-wire1x Pt1000 / 2-wire1x NiCr-Ni (Type K)2x NiCr-Ni (Type K)1x Fe-CuNi (Type J) 2x Fe-CuNi (Type J)
1 4
7 2 5 3 6
1 4
7 2 5 3 6
1
7
1
7
1 4 8 7 2 5 3 6
1 4 8 7 2 5 3 6
1 4
7
1 4
7
1
7
1
7
1
7
1 4
7 2
3
Head transmitter
Without transmitterWith 4...20 mAWith 0...10 V
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2
0 1
0 1
0 0 0 0
Scale
only °C°C and °F
0 0 0 0 2
0 0 0 0 0 2
0 2
0 0 2
216
TEMPERATURE SENSORS
J Machinery and plant engineering
J Maritime sector and shipbuilding
J Heating and air-conditioning
DS_Temperature_sensors 05/2014
Including products with:
218
„Made in Germany“ seal of quality
Customers are impressed by the durability, robustness and precision of our products. To ensure all quality requirements are met, SIKA develops and manufactures its product range exclusively in Germany. In this way, we guarantee smooth co-engineering between us and our clients, superior branded goods and excellent delivery reliability.
Individual advice from the experts
We work closely with you right from the development stage to create cost-effective special solutions with optimized technology.On site, our field sales staff are at your side to offer you sound, professional advice. Through collaboration with our internal product specialists and engineering department, the end result is a temperature sensor that fits your application perfectly. And in this development process, you get to benefit from our 20-plus years of engineering expertise.
From conceptual design to series production
As your dependable, able partner for special applications, SIKA assists you in finding an individual solution to your measuring problem, and develops temperature sensors that are tailored to your application. The focus here is on small and medium series.
Special applications are our strength
219
Durability and reliability are the hallmarks of our products
Temperature sensors have very distinct fields of operation and the conditions they are subject to are often harsh. A variety of requirements must be considered when developing the sensors:
• Special installation locations
• Special environmental conditions
• Vibration resistance
• Short response times
• Long service life
The advantage for you is that our experienced engineers are aware of these requirements and factor them into the product design, providing a reliable and targeted solution to the problem.
Tailor-made, time-tested solutions
Resistance thermometers for temperatures up to 1000 °C, and sensors with modern bus systems, are testament to our technological leadership in a wide variety of applications.
• Combustion engines
• Railway engineering
• Construction equipment
• Wind turbines
• Air conditioning systems
• Industrial dishwashers
• Coffee dispensers
Modern production and testing technologies
Extensive in-house manufacturing with modern production facilities enables the production of the most unique temperature sensors. To comply with the strict product requirements, SIKA performs numerous tests during development and manufacture, such as:
• Detection of curve errors
• Response time check
• High-voltage and insulation testing
• Helium leak tests
• Tensile strength test
• Fatigue tests
• Vibration test
• Climate test
• EMC test
Furthermore, the products are also subject to certification by classification societies for the maritime and energy industry, and to ATEX type examinations by independent testing labs and certification bodies.
220
Type WBC
For machinery and plant engineering
WBC
Temperature sensor with protection tube form 2 and compression-type fitting. This sensor is used in industrial applications for measuring liquid and gaseous media.
Technical features
• Variable fitting length and simple alignment of the connection head using sliding compression-type fitting
• Also available with clamping flange
• Available with optional instrument transformer
• Customer-specific fitting lengths and fixing thread on request
Measuring insert
According to DIN 43735, interchangeable, Ø 6 mm Measuring insert no. 61
Diameter
• 9 mm
• 11 mm
• 12 mm
Degree of protection
IP54
Max. Temperature
• 400 °C resistance thermometer
• 600 °C on request
• 800 °C thermocouple
Process connection
• Plain immersion tube
• Clamp coupling
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
221
Order code
Order example WB B C P31 0277 B0 0
Type
Resistance thermometerThermocouple
WBTB
Diameter F1
9 mm11 mm12 mm
BDC
Material
Stainless steel 1.4571 C
Sensor element
1 x Pt100 3-wire / class B2 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
1 x Fe-CuNi (type J)2 x Fe-CuNi (type J)1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
Resistance thermometer / class A
P31P32P41
J11J12K11K12
AXX
Length L1* Measuring insert L5*
277 mm 315 mm367 mm 405 mm517 mm 555 mm
027703670517
Electrical connection
Head form B with ceramic socketHead form B with transmitter**
B0BT
Process connection d1
WithoutG½ AG¾ A steel, galvanizedG¾ A stainless steelClamp flange DIN 43734
0JABC
* Other specifications available on request** For more information, see chapter temperature transmitters
222
W06
Temperature sensor with protection tube form 2 and fixed connecting thread. This sensor is used in industrial applications for measuring liquid and gaseous media.
Technical features
• Excellent price-performance ratio
• Available with optional instrument transformer
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Interchangeable only for Ø 8 mm
Diameter
• 6 mm
• 8 mm
Degree of protection
IP54
Max. Temperature
200 °C resistance thermometer
Process connection
Fix connecting thread
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
Type W06
Immersion tube
Head Form B
223
Order example W 06 1 P21 050 0 B0 6
Type
Resistance thermometer W
Diameter F1*
6 mm8 mm
0608
Material*
Brass 2.0401Stainless steel 1.4571
13
Sensor element
1 x Pt100 2-wire / class B2 x Pt100 2-wire / class B1 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
Resistance thermometer / class A
P21P22P31P41
AXX
Immersion tube length L1*
50 mm100 mm150 mm200 mm
050100150200
Measuring insert
Not interchangeableInterchangeable (only for Ø 8 mm)
02
Electrical connection
Head form B with ceramic socketHead form B with transmitter**
B0M0
Process connection d1
M14 x 1.5M18 x 1.5G¼ AG½ A
G6L2
* Other specifications available on request** For more information, see chapter temperature transmitters
Order code
224
WBF
Temperature sensor with protection tube form 2 G / 2F and neck pipe. This sensor is used in industrial applications for measuring liquid and gaseous media.
Technical features
• Neck pipe 125 mm or 25 mm
• Flange DN 25 and DN 40 available
• Available with optional instrument transformer
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class A and B
• Thermocouple class 1
Measuring insert
According to DIN 43735, interchangeable, Ø 6 mm or 8 mm Measuring insert no. 61 or 81
Diameter
• 9 mm
• 11 mm
• 14 mm
Degree of protection
IP54
Max. Temperature
• 400 °C resistance thermometer
• 600 °C on request
• 800 °C thermocouple
Process connection
• Plain immersion tube
• Fix connecting thread
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
Type WBF
225
Order code
Order example WB B C P31 0100 B0 0 00
Type
Resistance thermometerThermocouple
WBTB
Diameter F1
9 mm 11 mm14 mm
BDF
Material
Stainless steel 1.4571 C
Sensor element
1 x Pt100 3-wire / class B2 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
1 x Fe-CuNi (type J)2 x Fe-CuNi (type J)1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
Resistance thermometer / class A
P31P32P41
J11J12K11K12
AXX
Length L1* Measuring insert L5*
100 mm 255 mm160 mm 315 mm250 mm 405 mm400 mm 555 mm
0100016002500400
Electrical connection
Head form B with ceramic socketHead form B with transmitter**
B0BT
Process connection d1*
WithoutG½ AM20 x 1.5 (no DIN)G 1 AFlange DN 25Flange DN 40
0KGLF25F40
Options
Neck tube 25 mm 00
* Other specifications available on request** For more information, see chapter temperature transmitters
226
Temperature sensor with light plastic-sheathed cable. This sensor is used in industrial applications for measuring liquid and gaseous media.Thanks to the flexible light plastic-sheathed cable, even measurement points that are difficult to access can be reached. It is also extremely resistant to external
Technical features
• Short response time
• High vibration resistance
• Optional mit Messumformer lieferbar
• Kundenspezifische Einbaulängen und Einschraubgewinde möglich
Accuracy class
• Resistance thermometer class A and B
• Thermocouple class 1
Measuring insert
According to DIN 43735, interchangeable, Ø 6 mm Measuring insert no. 61
Diameter
6 mm
Degree of protection
IP54
Max. Temperature
• 400 °C resistance thermometer
• 600 °C on request
• 800 °C thermocouple
Process connection
• Plain immersion tube
• Clamp coupling
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
Type WMM
WMM
Leng
th
227
Order example WM M M P21 0250 B0 00
Type
Resistance thermometerThermocouple
WMTM
Diameter
6 mm M
Material
Stainless steel 1.4541 / 1.4571 M
Sensor element
1 x Pt100 2-wire / class B2 x Pt100 2-wire / class B1 x Pt100 3-wire / class B2 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
1 x Fe-CuNi (type J)2 x Fe-CuNi (type J)1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
Resistance thermometer / class A
P21P22P31P32P41
J11J12K11K12
AXX
Length NL*
250 mm290 mm350 mm380 mm410 mm530 mm630 mm710 mm800 mm
025002900350038004100530063007100800
Electrical connection
Head form B with ceramic socketHead form B with transmitter**
B0BT
Process connection
WithoutG¼ A steel, galvanizedG½ A steel, galvanizedG¼ A stainless steelG½ A stainless steel
00I8J8I3J3
* Other specifications available on request** For more information, see chapter temperature transmitters
Order code
228
WD0
Temperature sensor with protection tube form 4 and form DS. This sensor is supplied with a one-piece protection tube for welding and is designed for measuring liquid and gaseous media in industrial applications that are subject to high loads.
Technical features
• Numerous different protection tube materials available
• Test certificate in accordance with EN 10204 for the protection tube available
• Available with optional instrument transformer
Accuracy class
• Resistance thermometer class A and B
• Thermocouple class 1
Measuring insert
According to DIN 43735, interchangeable, Ø 3 mm or 6 mm Measuring insert no. 31 or 61
Diameter
• 24 mm conical
• 18 mm conical
Degree of protection
IP54
Max. Temperature
• 400 °C resistance thermometer
• 600 °C on request
• 800 °C thermocouple
Process connection
With welding tube
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
Type WD0
Form 4 Form DS
229
Order code
Order example W D0 C P31 07 D1 B00
Type
Resistance thermometerThermocouple
WT
Diameter
24 mm, immersion tube form 418 mm, immersion tube form DS
D0S0
Material
Stainless steel 1.4571Stainless steel 1.7380Stainless steel 1.5415Stainless steel 1.7335
CDEF
Sensor element
1 x Pt100 3-wire / class B2 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
1 x Fe-CuNi (type J)2 x Fe-CuNi (type J)1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
Resistance thermometer / class A
P31P32P41
J11J12K11K12
AXX
Inside diameter D1
7 mm (only form 4)3.5 mm (only form DS)
073A
Immersion tube length L Insertion length U Measuring insert length L5
Version Form 4140 mm 65 mm 315 mm200 mm 125 mm 375 mm200 mm 65 mm 375 mm260 mm 125 mm 435 mmVersion Form DS140 mm 65 mm 315 mm200 mm 125 mm 375 mm200 mm 65 mm 375 mm
D1D2D3D4
1S2S3S
Electrical connection
Head form B with ceramic socketHead form B with transmitter*
B00BT0
* For more information, see chapter temperature transmitters
230
Temperature sensor with angle plug as electrical connection. This sensor is designed with compact dimensions and is intended for use in industrial applications for measuring liquid and gaseous media.
Technical features
• High vibration resistance
• Reliable electrical connection using screw-on connectors
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Interchangeable only for Ø 8 mm
Diameter
• 6 mm
• 8 mm
Degree of protection
IP65
Max. Temperature
200 °C Resistance thermometer, max. 125 °C at plug
Process connection
Fix connecting thread
Electrical connection
Cable socket, angle type, DIN EN 175 301-803, form A
Approvals
Germanischer Lloyd
Type W30
W30
Cable socket, angle typeDIN EN 175301-803form A PA 6.6 (max. 125 °C)
Knurled nut, Ø30, Al, anodised or plastic nut
Seal, silicone
231
Order example W 06 1 P21 050 0 10 2 GL
Type
Resistance thermometerMeasuring insert
WE
Diameter
6 mm8 mm
0608
Material
Brass 2.0401 / 2.0402Stainless steel 1.4571
13
Sensor element
1 x Pt100 2-wire / class B1 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
Resistance thermometer / class A
P21P31P41
AXX
Immersion tube length L1*
Without (only for type measuring insert)50 mm100 mm150 mm200 mm
000050100150200
Measuring insert
Not interchangeableInterchangeable (only for Ø 8 mm)
02
Electrical connection
Cable socket, angle type form A 10
Process connection d1
G½ AM18 x 1.5M20 x 1.5G¾ A
26N3
Optionen
Version Germanischer Lloyd GL
* Other specifications available on request
Order code
232
Temperature sensor with angle plug as electrical connection. This sensor is designed with compact dimensions and is intended for use in industrial applications for measuring liquid and gaseous media.
Technical features
• High vibration resistance
• Reliable electrical connection using screw-on connectors
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class B
Measuring insert
Interchangeable
Diameter
• 6 mm
• 8 mm
Degree of protection
IP65
Max. Temperature
150 °C Resistance thermometer, max. 85 °C at plug
Process connection
Fix connecting thread
Electrical connection
• Cable socket, angle type DIN EN 175 301-803, form A With transmitter built into the sensor housing
• Output 4...20 mA, 2-wire, power supply 10...35 VDC
W3M
Type W3M
Cable socket, angle typeDIN EN 175301-803form A PA 6.6 (max. 125 °C)
Knurled nut, Ø30, Al, anodised or plastic nut
Seal, silicone
233
Order example W 06 1 P21 050 0 90 2
Type
Resistance thermometer W
Diameter F1
6 mm8 mm
0608
Material
Brass 2.0401 / 2.0402Stainless steel 1.4571
13
Sensor element
1 x Pt100 2-wire / class B P21
Immersion tube length L1*
50 mm100 mm150 mm200 mm
050100150200
Measuring insert
Not interchangeable 0
Electrical connection
Cable socket, angle type form A 90
Process connection d1
G½ AM18 x 1.5M20 x 1.5G¾ A
26N3
* Other specifications available on request
Order code
234
Temperature sensor with M12 angle plug as an electrical connection. This sensor is designed with very compact dimensions and is intended for use in industrial applications for measuring liquid and gaseous media.
Technical features
• High vibration resistance
• Reliable and compact electrical connection using M12 connector
• High degree of protection against ingress of moisture, dust and dirt
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Interchangeable only for Ø 8 mm
Diameter
• 6 mm
• 8 mm
Degree of protection
IP65
Max. Temperature
200 °C Resistance thermometer, max. 90 °C at plug
Process connection
Fix connecting thread
Electrical connection
• M12 cable socket, angle type, with knurled nut
• Head form J made of aluminium diecasting, silver finish, max. temperature 200 °C
W08
Type W08
Cable socket, angle type
Immersion tube
235
Order example W 06 3 P21 050 0 30 G
Type
Resistance thermometer W
Diameter F1
6 mm8 mm
0608
Material
Stainless steel 1.4571 3
Sensor element
1 x Pt100 2-wire / class B2 x Pt100 2-wire / class B1 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
Resistance thermometer / class A
P21P22P31P41
AXX
Immersion tube length L1*
50 mm100 mm150 mm200 mm
050100150200
Measuring insert
Not interchangeableInterchangeable (only for Ø 8 mm)
02
Electrical connection
M12 Cable socket, angle type roundHead form J
30J0
Process connection d1
M14 x 1.5M10 x 1.0G¼ AG½ A
GPL2
* Other specifications available on request
Order code
236
Temperature sensor with spring-loaded immersion tube. This sensor was specially developed for measuring temperatures in gearbox mounts. The spring loading maintains a constant contact pressure between the sensor and the measurement point, thus ensuring excellent thermal coupling.A special seal between the immersion tube and the screw connection guarantees outstanding insulation.
Technical features
• High vibration resistance
• Reliable and compact electrical connection using M12 connector
• High degree of protection against ingress of moisture, dust and dirt
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Not interchangeable
Diameter
6 mm
Degree of protection
IP65
Max. Temperature
200 °C Resistance thermometer, max. 80 °C at plug
Process connection
Fix connecting thread
Insertion length
Variable, spring-loaded 10 mm
Electrical connection
• Small cable socket, angle type, with knurled nut
• Head form J made of aluminium diecasting, silver finish, max. temperature 200 °C
Type WJK
WJK
* +10 mm spring travel
L1 -
10 m
m sp
ring
trav
el
237
Order example W 06 1 P21 065 0 30 2JK
Type
Resistance thermometer W
Diameter
6 mm 06
Material
Brass 2.0401Stainless steel 1.4571
13
Sensor element
1 x Pt100 2-wire / class B2 x Pt100 2-wire / class B1 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
Resistance thermometer / class A
P21P22P31P41
AXX
Immersion tube length L1*
55-65 mm 95-105 mm135-145 mm165-175 mm
065105145175
Measuring insert
Not interchangeable 0
Electrical connection
Cable socket, angle type round / M12Head form J
30J0
Process connection d1
G½ AM18 x 1.5
2JK6JK
* Other specifications available on request
Order code
238
Temperature sensor with integrated instrument transformer and plug connection. This sensor is characterised by its robust construction and is intended for use in harsh environments such as construction and mining machines. The instrument transformer integrated into the housing offers an interference-proof and standardised output signal.
Technical features
• Very high vibration resistance
• Exceptionally durable connecting cable
• Reliable electrical connection thanks to robust Deutsch connector system
• High degree of protection against ingress of moisture, dust and dirt
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class B
Measuring insert
Not interchangeable
Diameter
7 mm
Degree of protection
IP54
Max. Temperature
150 °C Resistance thermometer, max. 85 °C at plug
Process connection
Fix connecting thread
Electrical connection
• Connection cable with plug sensor housing with built-in transducer
• Output 4...20 mA, 2-wire, power supply 10...35 VDC
• Output 0...10 V, 3-wire, power supply 15...30 VDC
WKO
Type WKO
239
Order example W 07 1 P21 030 27 2 01 I
Type
Resistance thermometer W
Diameter
7 mm 07
Material
Brass 2.0401Stainless steel 1.4571
13
Sensor element
1 x Pt100 2-wire / class B P21
Length L1*
30 mm100 mm
030100
Electrical connection
FEP-cable, wire-braidedKENPUR 500, orange
27xx
Process connection d1*
G½ A 2
Cable length LK
1.0 m1.5 m2.0 m2.5 m
01020304
Signal output
4...20 mA, 2-wire0...10 V, 3-wire
IU
* Other specifications available on request
Order code
240
Temperature sensor with light plastic-sheathed cable. This sensor is used for measuring liquid and gaseous media. Thanks to the flexible light plastic-sheathed cable, even measurement points that are difficult to access can be reached. It is also extremely resistant to external temperature influences.
Technical features
• Short response time
• High vibration resistance
• Connecting cable available with different insulating materials depending on application. Shielded variant also available on request
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class A and B
• Thermocouple class 1
Measuring insert
Interchangeable, Ø 6 mm Measuring insert no. 61
Diameter
• 3 mm
• 6 mm
Degree of protection
IP54
Max. Temperature
• 400 °C resistance thermometer
• 600 °C on request
• 800 °C thermocouple
Process connection
• Plain immersion tube
• Clamp coupling
Electrical connection
Cable
WMQ
Type WMQ
Cable
Shrink hose
6-way squeezed
Jacket wire orjacket thermocoupleØ 3 mm
Delivery optionalwith clamp conenction
241
Order example WM Q M P21 0100 P0 0 01
Type
Resistance thermometerThermocouple
WMTM
Diameter F1
3 mm6 mm
QM
Material
Inconel 2.4816Stainless steel 1.4571
HM
Sensor element
1 x Pt100 2-wire / class B2 x Pt100 2-wire / class B1 x Pt100 3-wire / class B2 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
1 x Fe-CuNi (type J)2 x Fe-CuNi (type J)1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
Resistance thermometer / class A
P21P22P31P32P41
J11J12K11K12
AXX
Length L1*
100 mm150 mm200 mm250 mm500 mm
01000150020002500500
Electrical connection
PVC cableFibre glass, wire-braidedSilicone cableFEP cable
P080S0F0
Process connection
WithoutG¼ A steel, galvanizedM10 x 1 steel, galvanizedG¼ A stainless steel 1.4571G½ A stainless steel 1.4571M10 x 1 stainless steel
0IAFKB
Cable length LK*
1.0 m 01
* Other specifications available on request
Order code
242
W20
Temperature sensor with connection head form B. This robust sensor is used for measuring exhaust gas temperatures. It is used in large diesel engines such as those on ships and in combined heat and power stations. It is also used in turbines and compressors.
Technical features
• Very high vibration resistance
• One-piece protection tube
• Available with optional instrument transformer
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class B
• Thermocouple class 1
Measuring insert
Interchangeable
Diameter
• 14 / 17 mm conical up to 150 mm
• 17 / 23 mm conical up to 150 mm
• 20 / 23 mm conical from 200 mm
Degree of protection
IP54
Max. Temperature
Depending on Immersion tube material
Process connection
Fix connecting thread
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
Approvals
Germanischer Lloyd
For maritime sector and shipbuilding
Type W20
≈121
25
25L1
SW24
SW24, 1.4571
SW1, 1.4571
d1
F1
Head form B
Cu seal
Cu seal
243
Order code
Order example W 17 3 P31 100 2 B0 3T6
Type
Resistance thermometerThermocouple
WT
Diameter F1
14 / 17 mm conical up to 150 mm17 / 23 mm conical up to 150 mm20 / 23 mm conical from 200 mm
141720
Material
Stainless steel 1.4571 (max. 450 °C)Stahl 1.7335, heat-resistant (max. 600 °C)
35
Sensor element
1 x Pt100 3-wire / class B1 x Pt1000 2-wire / class B
1 x Fe-CuNi (type J)2 x Fe-CuNi (type J)1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
Resistance thermometer / class A
P31P12
1TJ2TJ1TK2TK
AXX
Length L1*
100 mm120 mm150 mm200 mm250 mm300 mm
100120150200250300
Measuring insert
Interchangeable 2
Electrical connection
Head form B with ceramic socketHead form B with transmitter**
B0BT
Process connection d1*
G½ A (for Ø 14 / 17 mm)G¾ AM27 x 2M33 x 2
2T63T6HT6FT6
* Other specifications available on request** For more information, see chapter temperature transmitters
244
Temperature sensor with connecting cable. This robust sensor is designed for measuring exhaust gas temperatures. It is used in large diesel engines such as those on ships and in combined heat and power stations. It is also used in turbines and compressors.
Technical features
• Very high vibration resistance
• One-piece protection tube
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class B
• Thermocouple class 1
Measuring insert
Interchangeable
Diameter
12 mm
Degree of protection
IP54
Max. Temperature
600 °C
Process connection
Fix connecting thread
Electrical connection
Cable
Type T12
T12
245
Order code
Order example T 12 3 P31 120 20 5 2 01
Type
ThermocoupleResistance thermometer
TW
Diameter
12 mm 12
Material
Stainless steel 1.4571 3
Sensor element
1 x Pt100 3-wire / class B1 x Fe-CuNi (type J)1 x NiCr-Ni (type K)
P311TJ1TK
Immersion tube lenght L1*
120 mm150 mm170 mm200 mm220 mm250 mm
120150170200220250
Measuring insert
Interchangeable 20
Electrical connection
FEP-cable, wire-braided 5
Process connection d1*
G½ AG¾ AM27 x 2M33 x 2
23HF
Cable length LK*
1.0 m 01
* Other specifications available on request** For more information, see chapter temperature transmitters
246
Temperature sensor with connecting cable. This robust sensor is designed for measuring exhaust gas temperatures. It is used in diesel engines such as those on ships and in combined heat and power stations. It is also used in turbines and compressors.
Technical features
• Compact design
• Very high vibration resistance
• One-piece protection tube
• Exceptionally durable connecting cable
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Thermocouple class 1
Measuring insert
Interchangeable
Diameter
Conical 10 mm to 8 mm
Degree of protection
IP54
Max. temperature
850 °C for thermocouple
Process connection
Fix connecting thread
Electrical connection
Cable
Approvals
Germanischer Lloyd
T10
Type T10
247
* Other specifications available on request
Order example T 10 0 1TK 065 2 70 L 01
Type
Thermocouple T
Diameter
10 mm 10
Material
Steel 1.4876 0
Sensor element
1 x NiCr-Ni (Type K) 1TK
Length L1*
65 mm95 mm
065095
Measuring insert
Interchangeable 2
Electrical connection
FEP-cable, wire-braided 70
Process Connection d1*
M14 x 1.5G¼ A
GL
Cable length LK*
1.0 m1.5 m2.0 m2.5 m
01020304
Order code
248
Temperature sensor with connecting cable. This robust sensor is designed for measuring exhaust gas temperatures. It is used in diesel engines such as those on ships and in combined heat and power stations. It is also used in turbines and compressors.
Technical features
• High vibration resistance
• Optional protection tube available
• Exceptionally durable connecting cable
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Thermocouple class 2
Measuring insertNot demountable
Diameter
9.5 mm
Degree of protection
IP54
Max. temperature
600 °C for thermocouple
Process connection
• Without
• Clamp coupling
Electrical connection
• FEP cable, wire-braided
• Fibre glass, wire-braided
T95
LK
L1
Type T95
249
* All other lengths are also available on request
Order code
Order example T95 3 1TK 2000 07 0 02
Diameter
9.5 mm T95
Material
Stainless steel 1.4571 3
Sensor element
1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
1TK2TK
Length NL*
200 mm250 mm290 mm
200025002900
Electrical connection
FEP cable, wire-braidedFibre glass, wire-braided
0708
Process connection
WithoutAdjustable union nut M18 x 1.5
01
Cable length LK*
1.5 m2.5 m5.0 m
020309
250
Temperature sensor with connecting cable. This robust sensor is designed for measuring exhaust gas temperatures. It is used in large diesel engines such as those used on ships and in combined heat and power stations. It is also used in turbines and compressors.
Technical features
• Very high vibration resistance
• Exceptionally durable connecting cable
• Customer-specific fitting lengths on request
Accuracy class
Thermocouple class 1
Measuring insert
Interchangeable
Diameter
4.5 mm
Degree of protection
IP54
Max. temperature
800 °C for thermocouple
Process connection
Fitting
Electrical connection
Cable, wire-braided
Approvals
Germanischer Lloyd
T45
Type T45
251
Order example T 45 3 1TK 045 07 01 01
Type
Thermocouple T
Diameter
4.5 mm 45
Material
Stainless steel 1.4541Inconel 2.4816
34
Sensor element
1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
1TK2TK
Length L1*
45 mm80 mm104 mm138 mm150 mm
045080104138150
Electrical connection
FEP cable, wire-braided 07
Process connection*
Fitting SW5, 3-4 mm, stainless steel 1.4571 01
Cable length LK
1,0 m1,5 m2,0 m2,5 m
01020304
Order code
* Other specifications available on request
252
Temperature sensor with connecting cable and Cannon connector. This robust sensor is designed for measuring exhaust gas temperatures. It is used in diesel engines such as those on ships and in combined heat and power stations. It is also used in turbines and compressors.Thanks to the flexible light plastic-sheathed cable, even measurement points that are difficult to access can be reached. It is also extremely resistant to external temperature influences.
Technical features
• Reliable electrical connection thanks to robust Cannon connector system
• High vibration resistance
• Optional protection tube available
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Thermocouple class 2
Measuring insertNot demountable
Diameter
5.2 mm
Degree of protection
IP54
Max. temperature
800 °C for thermocouple
Process connection
Without or with clamp coupling
Electrical connection
Mineral insulated cable with Cannon plug
T55
M12 x 1
L1
Ø 5.2
10
Type T55
253
* All other lengths are also available on request
Order code
Order example T55 3 1TK 1500 X0 R
Diameter
5.2 mm T55
Material
Stainless steel 1.4571 3
Sensor element
1 x NiCr-Ni (type K)2 x NiCr-Ni (type K)
1TK2TK
Length L1*
1500 mm 1500
Electrical connection
Mineral insulated cable with Cannon plug X0
Process connection
M12 x 1 R
254
Temperature sensor with connecting cable. This robust sensor is designed for measuring exhaust gas temperatures. It is used in diesel engines such as those on ships and in combined heat and power stations. It is also used in turbines and compressors.
Technical features
• High vibration resistance
• Exceptionally durable connecting cable
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class B
• Thermocouple class 1
Measuring insert
Not interchangeable
Diameter
• 8 mm
• 12 mm
Degree of protection
IP54
Max. Temperature
• 600 °C resistance thermometer
• 800 °C thermocouple
Process connection
• Plain immersion tube
• Clamp coupling
Electrical connection
Compensation pipe, wire-braided
Approvals
Germanischer Lloyd (only for type TWE)
Type TWE
TWE
Protectivespring
255
Order code
Order example TVA C J11 0100 07 0 01
Diameter F1
8 mm12 mm
TVATWE
Material
Stainless steel 1.4571 C
Sensor element
1 x Fe-CuNi (type J)1 x NiCr-Ni (type K)1 x Pt100 3-wire / class B (type TWE only)2 x Pt100 3-wire / class B (type TWE only)
J11K11P31P32
Length L1*
100 mm150 mm200 mm250 mm
0100015002000250
Electrical connection
FEP-cable, wire-braidedFibre glass, wire-braided
0708
Process connection d1*
WithoutG¼ steel, galvanizedG½ steel, galvanizedG½ stainless steelM27 x 2 steel, galvanized
0IKJH
Cable length LK*
1.0 m 01
* Other specifications available on request
256
Temperature sensor with connection head form B. This robust sensor is designed for use in industrial and marine applications for measuring the temperature of cooling water, lubricants and hydraulic oil.
Technical features
• High vibration resistance
• One-piece protection tube
• Available with optional instrument transformer
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Interchangeable
Diameter
• 12 mm
• 14 mm
Degree of protection
IP54
Max. Temperature
200 °C resistance thermometer
Process connection
Fix connecting thread
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 200 °C
Head Form B
Cu seal
Cu seal
Type W12
W12
257
Order code
Order example W 12 3 P31 080 2 B0 2T2
Type
Resistance thermometer W
Diameter F1
12 mm14 mm
1214
Material
Stainless steel 1.4571 3
Sensor element
1 x Pt100 3-wire / class B2 x Pt100 3-wire / class B1 x Pt100 4-wire / class B
Resistance thermometer / class A
P31P32P41
AXX
Immersion tube length U1*
80 mm100 mm120 mm150 mm200 mm250 mm
080100120150200250
Measuring insert
Interchangeable 2
Electrical connection
Head form B with ceramic socketHead form B with transmitter**
B0BT
Process connection E*
G½ AG¾ AM27 x 2M33 x 2
2T23T2HT2FT2
* Other specifications available on request** For more information, see chapter temperature transmitters
258
Temperature sensor with connection head form J. This robust sensor is designed for use in industrial and marine applications for measuring the temperature of cooling water, lubricants and hydraulic oil.
Technical features
• Very high vibration resistance
• Simple alignment of the connection head
• One-piece protection tube
• Available with optional instrument transformer
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Interchangeable
Diameter
8 mm
Degree of protection
IP54
Max. Temperature
200 °C resistance thermometer
Process connection
Fix connecting thread
Electrical connection
Head form B made of aluminium diecasting, silver finish, max. temperature 125 °C
Approvals
ABS, BV, DNV, GL, LRS, RINA and Class NK
Type WMJ
WMJ
Zust Änderung Datum Name (Urspr.:)Bl.
Blatt
(Verwendungsbereich)
Datum NameBearb.
Gepr. Norm
Maßstab: (Gewicht)
(SIKA-Artikelnummer)
Dr. Siebert & KühnGmbH & Co KG Struthweg 7-934260 Kaufungen
(Werkstoff, Halbzeug) (Zul. Abw.) (Oberfläche)
(Ers. f.:) (Ers. d.:)
1:1
W083P220502J02WS
Widerstandsthermometer indrehbarer Ausführung
430-2433(K) 1 1
ISO 2768-m DIN ISO 1302
11.12.201313.12.2013
SadlowskiSadlowski
Wei
terg
abe
sow
ie V
ervi
elfä
ltig
ung
dies
er D
okum
ente
, V
erw
ertu
ng u
nd M
itte
ilung
ihr
es I
nhal
ts s
ind
verb
oten
,so
wei
t ni
cht
ausd
rück
lich
gest
atte
t. Z
uwid
erha
ndlu
ngen
ver
pflic
hten
zu
Sch
aden
ersa
tz.
All
e R
echt
e fü
r de
n Fa
ll d
er P
aten
t-,
Geb
rauc
hsm
uste
r- o
der
Ges
chm
acks
mus
tere
intr
agun
g vo
rbeh
alte
n.
SIK
A U
nter
nehm
ensg
rupp
e, K
aufu
ngen
, D
euts
chla
nd.
Any
una
utho
rize
d co
pyin
g, d
iscl
osur
e or
dis
trib
utio
n of
thi
s do
cum
ent
and
its
cont
ents
is
stri
ctly
for
bidd
enun
less
spe
cifi
call
y au
thor
ised
. A
ny v
iola
tion
will
lea
d to
ind
emni
ty.
All
rig
hts
rese
rved
, pa
rtic
ular
ly i
n th
e ev
ent
of p
aten
t gr
ant,
reg
istr
atio
n of
a u
tilit
y m
odel
or
desi
gn p
aten
t.S
IKA
Com
pany
Gro
up,
Kau
fung
en,
Ger
man
y
SW24
SW22
14
8
d1
L1≈81
rot/red rot/red
weiß/white weiß/white
259
Order code
Order example W0 8 3 P31 050 2 J0 2
Type
Resistance thermometer W0
Diameter
8 mm 8
Material
Stainless steel 1.4571 3
Sensor element
1 x Pt100 3-wire / class B2 x Pt100 2-wire / class B1 x Pt1000 2-wire / class B2 x Pt1000 2-wire / class B
Resistance thermometer / class A
P31P22P12P24
AXX
Immersion tube length L1*
50 mm80 mm100 mm150 mm
050080100150
Measuring insert
Interchangeable 2
Electrical connection
Head form J with ceramic socketHead form J with transmitter** (without approvals)
J0JT
Process connection d1*
G½ AG¼ AG¾ A
2L3
* Other specifications available on request** For more information, see chapter temperature transmitters
260
Temperature sensor with connecting cable. This robust sensor is designed for use in industrial and marine applications for measuring the temperature of cooling water, lubricants and hydraulic oil.
Technical features
• High vibration resistance
• Exceptionally durable connecting cable
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Interchangeable
Diameter
11 mm
Degree of protection
IP54
Max. Temperature
200 °C resistance thermometer
Process connection
Fix connecting thread
Electrical connection
Cable
W11
Type W11
11
d1
L1
LK≈ 50
261
Order example W 11 3 P31 080 20 5 2 01
Type
Resistance thermometer W
Diameter
11 mm 11
Material
Stainless steel 1.4571 3
Sensor element
1 x Pt100 3-wire / class BResistance thermometer / class A
P31AXX
Immersion tube length L1*
80 mm100 mm120 mm150 mm200 mm250 mm
080100120150200250
Measuring insert
Interchangeable 20
Electrical connection
FEP cable, wire-braided 5
Process connection d1*
G½ AG¾ AM20 x 1.5M27 x 2
23HF
Cable length LK*
1.0 m 01
* Other specifications available on request
Order code
262
For heating and air-conditioning
Temperature sensor with connecting cable . This sensor was specially developed for use in solar thermal energy plants.Thanks to the optional digital sensor with 1-wire Bus interface, only one connecting cable is required for communication and voltage supply. A large number of sensors can communicate on a bus line with the control system.
Technical features
• High electric strength
• Water-proof and steam-proof connection between bush and connecting cable
• Connecting cable available with different insulating materials depending on application. Shielded variant also available on request
Accuracy class
• Resistance thermometer class A and B
• Digital 1-wire bus temperature sensor ±0.5 °C (-10…85 °C)
Measuring insert
Not interchangeable
Diameter
• 4 mm
• 5.2 mm
• 6 mm
Degree of protection
IP54
Max. Temperature
Depending on connecting cable
Process connection
• Plain immersion tube
• Clamp coupling
Electrical connection
Cable
W04
Type W04
Cable
pressed
Deep drawing casing
263
Order example W 04 3 P21 040 001 0 01
Type
Resistance thermometer W
Diameter F1 Deep drawing casing length L1*
4 mm 40 mm**5.2 mm 57 mm6 mm 60 mm
040506
040057060
Material
Stainless steel 1.4571 3
Sensor element*
1 x Pt100 2-wire / class B2 x Pt100 2-wire / class B1 x Pt100 3-wire / class B (only for Ø 6 mm)1 x Pt100 4-wire / class B (only for Ø 6 mm)1 x Pt1000 2-wire / class B1 x DS18B20U + (digital) integrated protection circuit (Ø 6 mm only)
Resistance thermometer / class A
P21P22P31P41P12E01
AXX
Connection cable Temperature range
PVC cable (not for Ø 4 mm) -50...80 °CPVC cable, shielded (not for Ø 4 mm) -20...80 °CSilicone cable -20...180 °CSilicone cable, shielded (not for Ø 4 mm) -20...180 °CFEP cable (not for Ø 4 mm) -20...200 °CFibre glass, wire-braided (not for Ø 4 mm) 300...400 °C
001002003004005008
Process connection
WithoutM10 x 1G¼ A
0DI
Cable length LK*
1.0 m 01
* Other specifications available on request** 40 mm length is also available for Ø 6 mm
Order code
264
WBA
Surface temperature sensor with connecting cable. This sensor is designed for measuring surface temperatures by means of installation or bonding. This sensor is used e.g. on panel heaters.Indirect temperature measurement means that measurements do not need to be taken directly in the process. This prevents chemicals, for example, from influencing the sensor. Thanks to the optional digital sensor with 1-wire Bus interface, only one connecting cable is required for communication and voltage supply. A large number of sensors can communicate on a bus line with the control system.
Technical features
• Simple assembly
• High electric strength
• Water-proof and steam-proof connection between bush and connecting cable
• Available with optional drill hole to enable attachment to surfaces
• Connecting cable available with different insulating materials depending on application. Shielded variant also available on request
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class A and B
• Temperature sensor NTC 5k ±0.5 °C (beta 1 %)
• Digital 1-wire bus temperature sensor ±0.5 °C (-10…85 °C)
Measuring insert
Not interchangeable
Diameter
SW6 / SW8
Degree of protection
IP54
Max. temperature
70 °C resistance thermometer
Process connection
Square for build-in or glue-in
Electrical connection
Connection cable
Type WBA
Wei
terg
abe
sow
ie V
ervi
elfä
ltig
ung
dies
er D
okum
ente
, V
erw
ertu
ng u
nd M
itte
ilung
ihr
es I
nhal
ts s
ind
verb
oten
,so
wei
t ni
cht
ausd
rück
lich
gest
atte
t. Z
uwid
erha
ndlu
ngen
ver
pflic
hten
zu
Sch
aden
ersa
tz.
All
e R
echt
e fü
r de
n Fa
ll d
er P
aten
t-,
Geb
rauc
hsm
uste
r- o
der
Ges
chm
acks
mus
tere
intr
agun
g vo
rbeh
alte
n.
SIK
A U
nter
nehm
ensg
rupp
e, K
aufu
ngen
, D
euts
chla
nd.
Any
una
utho
rize
d co
pyin
g, d
iscl
osur
e or
dis
trib
utio
n of
thi
s do
cum
ent
and
its
cont
ents
is
stri
ctly
for
bidd
enun
less
spe
cifi
call
y au
thor
ised
. A
ny v
iola
tion
will
lea
d to
ind
emni
ty.
All
rig
hts
rese
rved
, pa
rtic
ular
ly i
n th
e ev
ent
of p
aten
t gr
ant,
reg
istr
atio
n of
a u
tilit
y m
odel
or
desi
gn p
aten
t.S
IKA
Com
pany
Gro
up,
Kau
fung
en,
Ger
man
y
Zust Änderung Datum Name (Urspr.:)Bl.
Blatt
(Verwendungsbereich)
Datum NameBearb.
Gepr. Norm
Maßstab: (Gewicht)
(SIKA-Artikelnummer)
Dr. Siebert & KühnGmbH & Co KG Struthweg 7-934260 Kaufungen
(Werkstoff, Halbzeug) (Zul. Abw.) (Oberfläche)
(Ers. f.:) (Ers. d.:)
W061C010400010SM
Widerstandsthermometer KTY81-210
430-2537(K) 1 1
ISO 2768-m DIN ISO 1302
11.12.201313.12.2013
SadlowskiSadlowski
F1
LK±5
0
45`
3
L1
265
Order code
Order example W 06 1 P12 040 01 0 01
Type
Resistance thermometer W
Square F1
SW6SW8
0608
Material
Brass 2.0401 / 2.0402Stainless steel 1.4571
13
Sensor element
1 x Pt1000 2-wire / class B1 x Pt1000 2-wire / class B1 x DS18B20U + (digital) integrated protection circuit1 x NTC 5k
P12P24E01N01
Length L1*
40 mm50 mm
040050
Electrical connection
PVC-connectionSilicone cableFEP-cableFEP-cable, wire-braidedDatabus-cable 120 Ohm, shieldedRadox-cable, shielded
01030507X1X2
Process connection*
Square for build-in or glue-inSquare with borehole 5 mm
01
Cable length LK
1.0 m1.5 m2.0 m2.5 m
01020304
* Other specifications available on request
266
Temperature sensor with M12 connector. This sensor is designed for measuring media, for example, in heating and air conditioning systems as well as in cooling circuits in machines and plants.Thanks to the optional digital sensor with 1-wire Bus interface, only one connecting cable is required for communication and voltage supply. A large number of sensors can communicate on a bus line with the control system.
Technical features
• High vibration resistance
• Reliable and compact electrical connection using M12 connector
• High degree of protection against ingress of moisture, dust and dirt
• Short response time
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class A and B
• Temperature sensor NTC 5k ±0.5 °C (beta 1 %)
• Digital 1-wire bus temperature sensor ±0.5 °C (-10…85 °C)
Measuring insert
Not interchangeable
Diameter
5.9 mm
Degree of protection
IP54
Max. temperature
100 °C resistance thermometer
Process connection
Fix connecting thread
Electrical connection
Plug M12 x 1, brass nickel-plated, max. temperature 100 °C
Type WDS
WDS
267
Order code
Order example W 06 1 P31 038 0 R0 R
Type
Resistance thermometer W
Diameter F1
6 mm 06
Material
Brass 2.0401 / 2.0402Stainless steel 1.4571
13
Sensor element
1 x Pt100 3-wire / class B2 x Pt100 2-wire / class B1 x Pt1000 2-wire / class B2 x Pt1000 2-wire / class B1 x DS18B20U + (digital) integrated protection circuit1 x NTC 5k
Resistance thermometer / class A
P31P22P12P24E01N01
AXX
Length L1*
38 mm50 mm80 mm100 mm150 mm
038050080100150
Measuring insert
Not interchangable 0
Electrical connection
Plug M12 x 1 R0
Process connection d1*
M12 x 1.5G¼ AG⅛ A
RLM
* Other specifications available on request
268
Temperature sensor with mini-fit connector. This sensor is designed for measuring media, for example, in heating and air conditioning systems as well as in cooling circuits in machines and plants.
Technical features
• Cost-effective electrical connection using mini-fit connector
• Short response time
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer B
• Temperature sensor NTC 5k ±0.5 °C (beta 1 %)
• Temperature sensor KTY 81-210 ± 1%
Measuring insert
Not interchangeable
Diameter
6.5 mm
Degree of protection
IP54
Max. Temperature
100 °C resistance thermometer
Process connection
Fix connecting thread
Electrical connection
Mini-fit plug, 2-pole, max. temperature 100 °C
WFI
Type WFI
Wei
terg
abe
sow
ie V
ervi
elfä
ltig
ung
dies
er D
okum
ente
, V
erw
ertu
ng u
nd M
itte
ilung
ihr
es I
nhal
ts s
ind
verb
oten
,so
wei
t ni
cht
ausd
rück
lich
gest
atte
t. Z
uwid
erha
ndlu
ngen
ver
pflic
hten
zu
Sch
aden
ersa
tz.
All
e R
echt
e fü
r de
n Fa
ll d
er P
aten
t-,
Geb
rauc
hsm
uste
r- o
der
Ges
chm
acks
mus
tere
intr
agun
g vo
rbeh
alte
n.
SIK
A U
nter
nehm
ensg
rupp
e, K
aufu
ngen
, D
euts
chla
nd.
Any
una
utho
rize
d co
pyin
g, d
iscl
osur
e or
dis
trib
utio
n of
thi
s do
cum
ent
and
its
cont
ents
is
stri
ctly
for
bidd
enun
less
spe
cifi
call
y au
thor
ised
. A
ny v
iola
tion
will
lea
d to
ind
emni
ty.
All
rig
hts
rese
rved
, pa
rtic
ular
ly i
n th
e ev
ent
of p
aten
t gr
ant,
reg
istr
atio
n of
a u
tilit
y m
odel
or
desi
gn p
aten
t.S
IKA
Com
pany
Gro
up,
Kau
fung
en,
Ger
man
y
Zust Änderung Datum Name (Urspr.:)Bl.
Blatt
(Verwendungsbereich)
Datum NameBearb.
Gepr. Norm
Maßstab: (Gewicht)
(SIKA-Artikelnummer)
Dr. Siebert & KühnGmbH & Co KG Struthweg 7-934260 Kaufungen
(Werkstoff, Halbzeug) (Zul. Abw.) (Oberfläche)
(Ers. f.:) (Ers. d.:)
W651PTC0151X0M
Temperatursensor Type KTY81/210
430-0860(K) 1 1
ISO 2768-m DIN ISO 1302
11.12.201313.12.2013
SadlowskiSadlowski
6,5
8,5
L19`
0,5
d1
13SW
269
Order code
Order example W 65 1 P21 015 0 X0 M
Type
Resistance thermometer W
Diameter
6.5 mm 65
Material
Brass CW602NStainless steel 1.4571 / 1.4404
13
Sensor element
1 x Pt100 2-wire / class B1 x Pt1000 2-wire / class B1 x NTC 5k1 x KTY81 / 210
P21P12N01PTC
Length L1*
15 mm30 mm
015030
Measuring insert
Not interchangeable 0
Electrical connection
Mini-fit, 2-pole X0
Process connection*
G⅛ A M
* Other specifications available on request
270
Temperature sensor with M8 connector. This sensor is designed for measuring media, for example, in heating and air conditioning systems as well as in cooling circuits in machines and plants.
Technical features
• Reliable and compact electrical connection using M8 connector
• Simple alignment of the electrical connection using optional vortex thread
• High degree of protection against ingress of moisture, dust and dirt
• Very short response time
• Customer-specific fitting lengths and fixing thread on request
Accuracy class
• Resistance thermometer class A and B
• Temperature sensor NTC 5k ±0.5 °C (beta 1 %)
Measuring insert
Not interchangeable
Diameter
4 mm
Degree of protection
IP54
Max. temperature
100 °C resistance thermometer
Process connection
• Fix connecting thread
• Vortex thread
Electrical connection
M8 plug, max. temperature 85 °C
WM8
Type WM8
Wei
terg
abe
sow
ie V
ervi
elfä
ltig
ung
dies
er D
okum
ente
, V
erw
ertu
ng u
nd M
itte
ilung
ihr
es I
nhal
ts s
ind
verb
oten
,so
wei
t ni
cht
ausd
rück
lich
gest
atte
t. Z
uwid
erha
ndlu
ngen
ver
pflic
hten
zu
Sch
aden
ersa
tz.
All
e R
echt
e fü
r de
n Fa
ll d
er P
aten
t-,
Geb
rauc
hsm
uste
r- o
der
Ges
chm
acks
mus
tere
intr
agun
g vo
rbeh
alte
n.
SIK
A U
nter
nehm
ensg
rupp
e, K
aufu
ngen
, D
euts
chla
nd.
Any
una
utho
rize
d co
pyin
g, d
iscl
osur
e or
dis
trib
utio
n of
thi
s do
cum
ent
and
its
cont
ents
is
stri
ctly
for
bidd
enun
less
spe
cifi
call
y au
thor
ised
. A
ny v
iola
tion
will
lea
d to
ind
emni
ty.
All
rig
hts
rese
rved
, pa
rtic
ular
ly i
n th
e ev
ent
of p
aten
t gr
ant,
reg
istr
atio
n of
a u
tilit
y m
odel
or
desi
gn p
aten
t.S
IKA
Com
pany
Gro
up,
Kau
fung
en,
Ger
man
y
Zust Änderung Datum Name (Urspr.:)Bl.
Blatt
(Verwendungsbereich)
Datum NameBearb.
Gepr. Norm
Maßstab: (Gewicht)
(SIKA-Artikelnummer)
Dr. Siebert & KühnGmbH & Co KG Struthweg 7-934260 Kaufungen
(Werkstoff, Halbzeug) (Zul. Abw.) (Oberfläche)
(Ers. f.:) (Ers. d.:)
1:1
W043P140150B00TR
WiderstandsthermometerPT1000/B/4 -10/+80
430-3280(K) 1 1
ISO 2768-m DIN ISO 1302
11.12.201313.12.2013
SadlowskiSadlowski
1 4
1
8M x1
SW8
5M
7
3
2 4
32
715
35
8SW
4
Wei
terg
abe
sow
ie V
ervi
elfä
ltig
ung
dies
er D
okum
ente
, V
erw
ertu
ng u
nd M
itte
ilung
ihr
es I
nhal
ts s
ind
verb
oten
,so
wei
t ni
cht
ausd
rück
lich
gest
atte
t. Z
uwid
erha
ndlu
ngen
ver
pflic
hten
zu
Sch
aden
ersa
tz.
All
e R
echt
e fü
r de
n Fa
ll d
er P
aten
t-,
Geb
rauc
hsm
uste
r- o
der
Ges
chm
acks
mus
tere
intr
agun
g vo
rbeh
alte
n.
SIK
A U
nter
nehm
ensg
rupp
e, K
aufu
ngen
, D
euts
chla
nd.
Any
una
utho
rize
d co
pyin
g, d
iscl
osur
e or
dis
trib
utio
n of
thi
s do
cum
ent
and
its
cont
ents
is
stri
ctly
for
bidd
enun
less
spe
cifi
call
y au
thor
ised
. A
ny v
iola
tion
will
lea
d to
ind
emni
ty.
All
rig
hts
rese
rved
, pa
rtic
ular
ly i
n th
e ev
ent
of p
aten
t gr
ant,
reg
istr
atio
n of
a u
tilit
y m
odel
or
desi
gn p
aten
t.S
IKA
Com
pany
Gro
up,
Kau
fung
en,
Ger
man
y
Zust Änderung Datum Name (Urspr.:)Bl.
Blatt
(Verwendungsbereich)
Datum NameBearb.
Gepr. Norm
Maßstab: (Gewicht)
(SIKA-Artikelnummer)
Dr. Siebert & KühnGmbH & Co KG Struthweg 7-934260 Kaufungen
(Werkstoff, Halbzeug) (Zul. Abw.) (Oberfläche)
(Ers. f.:) (Ers. d.:)
1:1
WXHÜTTINGER013
WiderstandsthermometerPT100/B/2 -10/+80
430-2234(K) 1 1
ISO 2768-m DIN ISO 1302
11.12.201313.12.2013
SadlowskiSadlowski
- 0,10,05+
15
8M7
≈18 SW10
34
1
1 4
M10
4,2
271
Order code
Order example W 04 3 P31 015 0 X0 L
Type
Resistance thermometer W
Diameter
4 mm 04
Material
Stainless steel 1.4571 3
Sensor element
1 x Pt100 3-wire / class B1 x Pt1000 2-wire / class B1 x NTC 5k
Resistance thermometer / class A
P31P12N01
AXX
Length*
15 mm 015
Measuring insert
Not interchangeable 0
Electrical connection
M8, 3-pole X0
Process connection*
M5M10 (with vortex thread)
LX
* Other specifications available on request
272
Temperature sensor for outside and wet room temperature measurement. This sensor is used in heating and air conditioning systems and in building services.
Technical features
• Housing made of impact-absorbing plastic
• Straightforward electrical connection using quick-release fasteners
• Available with external sensor tube
• Available with optional instrument transformer
Accuracy class
Resistance thermometer BTemperature sensor KTY 81-210 ± 1%
Measuring insert
Not interchangeable
Dimensions
72 x 64 x 32.4 mm
Degree of protection
IP65
Max. Temperature
-50...90 °C
Process connection
With screws for wall mounting
Electrical connection
0.14 - 1.5 m², with screw terminals
Type WIG
WIG
~10
7
72
64
14.8
37.8
M16x1,5
ø 6
30
~10
7
72
64
14.8
37.8
M16x1,5
~10
7
72
64
14.8
37.8
M16x1,5
ø 6
30
~10
7
72
64
14.8
37.8
M16x1,5
273
Order example SME8 ATF1WIGH P21 I
Type
Resistance thermometer SME8
Form
Casing without external sensor tubeCasing with external sensor tube
ATF1WIGHATF2WIGH
Sensor element*
1 x Pt100 2-wire / class B1 x Pt100 3-wire / class B1 x Pt1000 2-wire / class B1 x KTY 81-210
P21P31P12N01
Options
With transmitter 4...20 mAWith transmitter 0...10 V
IU
* Other specifications available on request
Order code
274
Temperature sensor for interior temperature measurement. This sensor is used in heating and air conditioning systems and in building services.
Technical features
• Housing made of impact-absorbing plastic
• With snap-on cap
• Available with optional instrument transformer
Accuracy class
Resistance thermometer class BTemperature sensor KTY 81-210 ± 1%
Measuring insert
Not interchangeable
Dimensions
85 x 91 x 27 mm
Degree of protection
IP30
Max. Temperature
-30...90 °C
Process connection
With screws for wall mounting
Electrical connection
0.14 - 1.5 m², with screw terminals
Type WIR
WIR
275
Order example SME8 RTF1WIGH P21 I
Type
Resistance thermometer SME8
Form
Casing RTF1WIGH
Sensor element*
1 x Pt100 2-wire / class B1 x Pt100 3-wire / class B1 x Pt1000 2-wire / class B1 x KTY 81-210
P21P31P12N01
Optionen
With Transmitter 4...20 mAWith Transmitter 0...10 V
IU
* Other specifications available on request
Order code
276
Temperature sensor with pipe clamp. This sensor is provided for use in industrial applications for measuring surface temperatures of pipe surfaces.
Technical features
• Simple assembly
• Connecting cable available with different insulating materials depending on application. Shielded variant also available on request
Accuracy class
Resistance thermometer class A and B
Measuring insert
Not interchangeable
Diameter
Diverse
Degree of protection
IP54
Max. Temperature
200 °C
Process connection
Hose clip stainless steel
Electrical connection
Silicone cable or fibre glass, wire-braided
WRO
Type WRO
Connection cable
Shrink hose
Hose clip width12 mm
277
Order example WRO C P31 0025 S00 01
Type
Resistance thermometer WRO
Form
Shrink hose C
Sensor element
1 x Pt100 3-wire / class BResistance thermometer class A
P31AXX
Diameter pipe*
15-25 mm 23-35 mm 32-50 mm 50-70 mm 70-90 mm 90-110 mm110-130 mm130-150 mm150-170 mm170-190 mm190-210 mm
00250035005000700090011001300150017001900210
Connection cable
Silicone cableFEP cableFibre glass, wire-braided
S00F00G00
Cable length LK*
1.0 m 01
* Other specifications available on request
Order code
278
279
PRESSURE SENSORS AND PRESSURE SWITCHES
J Relative pressure
J Absolute pressure
J Difference pressure
J Level measurement
J Pressure switches
DS_Pressure_sensors_and_pressure_switches 05/2014
280
Our pressure sensors are high-precision, thermally stable instruments that are designed for the measurement of pressure in liquids and gases. The functionality and sensor style are determined by the specific operating conditions. Thanks to the ease at which these reliable sensors can be installed, commissioned and operated, they are suitable for use in a wide variety of applications.
The in-depth knowledge and extensive expertise of our product specialists in both the field-sales and internal-sales teams translates to top-quality sensor solutions that are perfectly tailored to your measurement task. Furthermore, we also have a global network of hand-picked representatives.
Areas of application • Mechanical engineering
• Machine tools
• Measuring / control engineering
• Hydraulics / pneumatics
• Refrigeration technology
• Food industry
• Medical technology
• Filter control
• Automation
High-precision pressure measurement with SIKA
-281-281
By constantly examining technologies that can be applied to pressure measurement, we are committed to the continued refinement and development of our products.
Over the following pages you can get an insight into our extensive sensor portfolio, ranging from vacuum and pressure switches for liquids and gases, OEM pressure sensors for relative pressure measurement, sensors with a ceramic element for gauge pressure and differential pressure measurement, or piezoresistive solutions for absolute pressure, differential pressure or level measurement. Added to this, a wide range of bespoke special versions are also in use the world over.
282
Series DSW
Advantages
• Easy installation and commissioning
• Excellent value for money
• Short delivery times
• Linearity < 0.5 % of full scale value
• 2-fold overpressure-safe
Type DSW
Functional description
With this new pressure sensor, SIKA is ushering in a new generation of pressure measuring instruments for general industrial applications.
The DSW not only impresses users with its compact design, it also offers excellent quality at a very low price.
And with a range of international approvals, the DSW can be used worldwide. The various pressure ranges and process connections that are needed for the individual operating conditions are readily available.
Areas of application
• Mechanical engineering
• Machine tools
• Measuring / control engineering
• Hydraulics / pneumatics
• Pumps / compressors
Relative pressure
283
Technical data and dimensions
Technical data
General
Accuracy, linearity, hysteresis < ±0.5 % full scale
Temperature influence ≤ 1.0 % typ., ≤ 2.5 % max.
Response time < 4 msec
Medium temperature 0...80 °C (others on request)
Ambient temperature 0...80 °C (others on request)
Overpressure safety 2-fold full scale value
Fitting position Any
Connection G¼ A, ¼ NPT
Degree of protection IP65
Electrical data
Output / supply 4...20 mA, 8...30 VDC; 2-wire
Connection Angle plug DIN EN 175301-803 A
Load 2-wire: ≤ (Ub-8 V) / 0.02 A
Material
Housing Stainless steel 1.4404
Diaphragm NBR (nitrile butadiene)
Connection Stainless steel 1.4404
≈48
≈6114
SW27
∅28,5
G¼A
284
Order code
Order example DSW 43 1 H 1H 025Diaphragm
NBR (nitrile butadiene) 43Output
4...20 mAOthers
1X
SealingBack sealed H
Process connectionG¼ A¼ NPT
1H2H
Measuring range [bar]0...10...1.60...2.50...40...6
025035045055065
0...100...160...250...400...60
075085095105115
0...1000...1600...2500...4000...600
125135145155165
Other specifications on request
285
Advantages
• Good value
• Linearity < 0.5 % of full scale value
• 2-fold overpressure-safe
• High temperature resistance
• No mechanical ageing or creepage
• No filling liquid necessary
Type DSK
Functional description
A new type of ceramic sensor forms the core of these units.
It consists of a thin aluminium oxide diaphragm, on the rear side of which thick-film resistors are fitted in a Wheatstone bridge circuit.
For stabilisation purpose, this diaphragm is connected to a thickaluminium oxide baseplate and is mounted in an appropriate casing with threated connections.
If the diaphragm is subjected to pressure, it bends slightly and therby changing the resistance of the thick-film resistors.
A downstream electronic converts the resistance into an analog signal.
Areas of application
• Refrigeration technology
• Mechanical engineering
• Process engineering
• Hydraulics
Series DSK
286
Technical data
General
Accuracy, linearity, hysteresis < ±0.3 % full scale
Temperature influence < ±0.04 % full scale/K
Response time < 5 ms
Medium temperature -15...80 °C
Ambient temperature -15...80 °C
Overpressure safety 2-fold full scale value
Fitting position Any
Connection G¼ A, G½ A
Degree of protection IP65
Electrical data
Output / supply 4...20 mA, 11...33 VDC; 2-wire 0...5 V, 11...33 VDC; 3-wire0...10 V, 18...33 VDC; 3-wire
Connection Spark plug, DIN EN 175301-803 A
Load 2-wire: < (Ub-11 V) / 0.02 A 3-wire: > 10 kΩ / < 100 nF
Material
Housing Aluminium, anodised
Diaphragm FPM, NBR or EPDM
Connection Stainless steel 1.4305
Technical data and dimensions
to 40 bar to 60 bar
G G¼ A G½ A G¼ A G½ A
l 16 20 12 16
s 3 5 10≥100 bar = 69≤60 bar = 59
Ø 4
0
G
10
SW27
l
s
≥ 100 bar ~ 140 (mounted)≤ 60 bar ~ 94 (mounted)
287
Order code
* Only possible with Viton seal
Order example DSK 33 0 A 1H 315 ÖFDiaphragm
FKM (fluro-elastomer)NBR (nitrile butadiene)EPDM (ethylene butadiene)
334353
Output4...20 mA0...10 V0...5 V
123
SealingFront sealedBack sealed
AH
Process connectionG¼ AG½ A
1H3H
Measuring range [bar]-1...0-1...0.6-1...1.5-1...3-1...5
315505515525535
-1...90...0.30...0.60...10...1.6
545005015025035
0...2.50...40...60...100...16
045055065075085
0...250...400...600...1000...160
095105115125135
0...2500...400*0...600
145155165
OptionsOil and grease-free ÖF
288
Series DSA / DSP
Advantages
• High linearity < 0.5 % (0.25 %) of full scale value
• Good reproducibility
• Inside, front or front-flush diaphragm
• 3-fold overpressure-safe (max. bursting pressure)
• Robust design
Relative and absolute pressure
Type DSA
Functional description
Series DSA / DSP pressure sensors are used to measure relative pressure, overpressure or absolute pressure.
High-quality stainless steel and front-flush diaphragm also allow these sensors to be used in viscous or contaminated media.
The measuring element is a silicon chip, out of which a diaphragm has been etched. A Wheatstone bridge circuit is formed by the apllication of foreign ions to the silicon diaphragm.When the diaphragm bends, a resistance change results which is a measurement of the pressure. If the rear side of the chip is prestressed with a reference vaccum, absolute pressure can also be measured.
Since silicon chips are very sensitive, the entire chip is enclosed in a measurering element chamber. This is for reasons of media compatibility. The chamber is separated from the medium by a stainless steel diaphragm. The pressure is transmitted with neutral oil.
Areas of application
• Mechanical engineering
• Hydraulics
• Medical technology
289
Technical data
General
Accuracy, linearity, hysteresis ≤ ±0.25 % full scale
Temperature influence
0...70 °C (typical / max.)> 0.1...0.5 bar> 0.5...2 bar> 2...100 bar> 100...600 bar
≤ 1.0 % / 1.5 % full scale≤ 0.7 % / 1.0 % full scale≤ 0.7 % / 1.0 % full scale≤ 0.7 % / 1.0 % full scale
-25...100 °C (typical / max.)> 0.1...0.5 bar> 0.5...2 bar> 2...100 bar> 100...600 bar
≤ 2.0 % / 2.5 % full scale≤ 1.0 % / 1.5 % full scale≤ 1.0 % / 1.5 % full scale≤ 1.0 % / 1.5 % full scale
Response time < 1 ms / 10...90 % full scale
Medium temperature 0...70 °C-25...100 °C
Ambient temperature -40...100 °C
Overpressure safety 3-fold (min. 3 bar, max. burst pressure)
Connection G¼ A, G½ A, DIN and flange
Degree of protection IP65
Electrical data
Output / supply 4...20 mA, 11...33 VDC; 2-wire0...5 V, 15...33 VDC; 3-wire0...10 V, 15...33 VDC; 3-wire
Connection Angle plug, DIN EN 175301-803 A
Load 2-wire: (Ub-9 V) / 0.02 A3-wire: > 10 kΩ
Material
Housing Stainless steel 1.4435
Diaphragm FKM (Fluro-elastomer)
Connection Stainless steel 1.4435
Type DSA / DSP...A1H Type DSA / DSP...A3H
Technical data and dimensions
13,5
12
32,5
Ø27
Ø19
Ø24
Ø24
G 1
/2G
1/4
25
32,5 25
SW27
SW27
13,5
12
32,5
Ø27
Ø19
Ø24
Ø24
G 1
/2G
1/4
25
32,5 25
SW27
SW27
290
Order code
Order example DSA 24 1 A 1H 126Accuracy
0.25 % 24Output
4...20 mA0...10 V0...5 V
123
DiaphragmInsideFront (only G½ A possible)
AV
Process connectionG¼ AG½ A
1H3H
Measuring range [bar]0...0.10...0.160...0.250...0.40...0.6
126136146156015
0...10...1.60...2.50...40...6
025035045055065
0...100...16
075085
291
Order code
* nur mit G½ A möglich
Order example DSP 34 1 A 1H 126Accuracy
0.25 % 34Output
4...20 mA0...10 V0...5 V
123
DiaphragmInsideFront
AV
Process connectionG¼ AG½ A
1H3H
Measuring range [bar]0...0.10...0.160...0.250...0.40...0.6
126136146156015
0...10...1.60...2.50...40...6
025035045055065
0...100...160...250...400...60
075085095105115
0...1000...1600...2500...4000...600
125135145155165
292
Series DDS
Advantages
• Good value
• Linearity < 0.5 % of full scale value
• High temperature resistance
• No mechanical ageing
• Very low temperature sensitivity
• Protected against polarity change and short-circuit strength
• One-sided overload max. 2-folded pressure range
Difference pressure
Type DDS
Functional description
The structure of the difference pressure transmitter, series DDS, is based upon a new ceramic technology and is remarkable of a high temperature resistance and a special longterm stability.The thick-film resistors on the ceramic diaphragm form a Wheatstone bridge circuit.
The bridge circuit amplifier supplies the calibrated voltage or current signal as a standard signal.
The output signal is protected against polarity change and shortcircuit strength.
Areas of application
• Gaseous and liquid medium
• Heating technique
• Filter control
• Process engineering
293
Technical data
General
Accuracy, linearity, hysteresis < 0.5 % full scale
Temperature influence < 0.06 % full scale
Response time < 5 msec
Medium temperature -15...80 °C
Overpressure safety Max. 2-folded pressure range
Connection NozzleScrewed pipe joint
Degree of protection IP65With cable socket IP67
Static pressure Max. 25 bar
Electrical data
Output / supply 4...20 mA, 11...33 VDC; 2-wire0...10 V, 18...33 VDC; 3-wire0...5 V, 11...33 VDC; 3-wire
Connection Angle plug, DIN EN 175301-803 APlug DIN EN 60130-91.5 m cable with PG screwing
Load 2-wire: (Ub-11 V) / 0.02 A3-wire: >10 kΩ
Material
Housing Stainless steel 1.4305
Diaphragm FPM, EPDM, NBR, MVQ, CR
Connection Stainless steel 1.4305
Technical data and dimensions
SteckdoseDIN EN 175301-803-A
Stai
nles
s st
eel ~
136
/ PVD
F ~1
30 (m
ount
ed)
294
Order code
Order example DDS 33 1 H1 1 100Sealing material
FPM (fluro-elastomer)EPDM (ethylene butadiene)MVQ (silicone polymer)NBR (nitrile butadiene)CR (chloropren-butadiene)
3353634373
Output4...20 mA0...10 V0...5 V
2-wire3-wire3-wire
123
Process connectionTube connectionScrewed pipe joint
CuZn, 6 mm1.4305, 6 mm1.4305, 8 mm
H1H3H4
Electr. connectionAngle plug, DIN EN 175301-803 ACable 1.5 m with PG screwingPlug DIN EN 60130-9
123
Measuring range [bar]0...0.10...0.20...0.250...0.30...0.4
110120125130140
0...0.50...0.60...10...1.60...2.5
150160200216225
0...40...60...100...160...25
240260300316325
295
Series DSN / DSL
Advantages
• Linearity < 0.5 % (0.25 %) of full scale value
• 3-fold overpressure-safe
• Mechanically protected diaphragm
• 100 % leak-proof by virtue of being
• Fully welded
Level measurement
Type DSN
Functional description
Series DSN / DSL pressure sensors are mainly used to measure liquid filling levels.
The measuring element is a silicon chip, out of wich a diaphragm has been etched. A Wheatsone bridge circuit is formed by application of foreign ions to the silicon diaphragm.
When the diaphragm bends, a resistance change results which is a measurement of the pressure. In the level probe design the rear side of the diaphragm is connected to the surrounding air pressure by a compensating line.
The units can also be used in troubled media.
Areas of application
• Wells
• Open containers
• Bodies of water
296
Technical data and dimensions
Technical data
General
Accuracy, linearity ≤ ±0.25 % full scale
Temperature influence
-5...50 °C (typical / max.)> 1...5 bar> 5...20 bar
≤ 1 % / 1.5 % full scale≤ 0,7 % / 1 % full scale
-5...80 °C (typical / max.)> 1...5 bar> 5...20 bar
≤ 2 % / 2.5 % full scale≤ 1 % / 1.5 % full scale
Response time < 1 msec / 10...90 % full scale
Medium temperature -5...50 °C (-5...80 °C on request)
Overpressure safety 3-fold full scale value (min. 3 bar)
Degree of protection IP68
Electrical data
Output / supply 4...20 mA, 9...33 VDC; 2-wire0...5 V, 12...30 VDC; 3-wire0...10 V, 12...30 VDC; 3-wire0...20 mA, 18...33 VDC; 3-wire
Connection Cable with air pressure compensating tube
Load 2-wire: < (Ub-11V) / 0,02 A 3-wire: < 250 Ω
Material
Housing Stainless steel 1.4404
Diaphragm Viton (Standard), EPDM
Cabel PUR, FEP* or PE*
* On request
Ø6 P
E-/PU
R cable
Ø5 Teflon cable
DSN - without ballast weight 88DSL - with ballast weight 175
A [mm]
297
Order code
Order example DS N 23 000K 126 010Construction
ShortLong
NL
Accuracy0.25 % 24
Output4...20 mA0...10 V0...5 V
100K200K300K
Measuring range [bar]0...0.10...0.160...0.250...0.40...0.6
126136146156015
0...10...1.60...2.50...40...6
025035045055065
0...100...16
075085
Cable length [m]P. e. 10 m cable PUR XXX
298
Series DSU / DSV
Advantages
• Pressure range 2...6000 mbar
• Reproducibility 5 %
• Temperature range -40...80 °C
• High operation safety because of robust mechanics
• Switching difference adjustable
• Changeable as contact
• Maximum overpressure 1.5-fold operating pressure
Vacuum and pressure switches for liquids and gases
Type DSU 620
Type DSV 625
Functional description
Series DSU / DSV vacuum and pressure switches are used for surveilllance of liquids and gas in industrial applications.
The robust mechanics guarantees a highly operation safety, even in case of vibrations.
The units posses a highly long-term stability of the adjusted switch points.
They are especially remarkable of a standard program with many different versions and an ideal cost effectiveness.
Areas of application
• Process engineering
• Automation
• Heating, climate, ventilation
299
Technical data
General
Smallest cutting-in pressure 2 mbar
Smallest switching difference 1 mbar
ReproducibilityDiaphragm NBR or siliconDiaphragm FPM and EPDM
5 %10 %
Medium temperatureDiaphragm NBRDiaphragm FPM und EPDMDiaphragm silicon
0...80 °C-10...80 °C-40...80 °C
Connection Nozzle 6 mm or female thread M5Thread: G⅛ A, G¼ A, M12 x 1
Degree of protection IP54 with covering hoodIP00 without covering hood
General technical data
Connections AMP plug 6.3 mm
Contact system Switch 250 DAC 1 A or 6 A
Cable screw Screwing PG 9
Technical data and dimensions
Type DSU 620 Type DSU 625 Type DSV 625
300
Order code
Order example DSU 620 1 1H 008
Diaphragm
NBRFPMEPDMMVQ
nitrile butadienefluro-elastomerethylene butadienesilicone polymer
1234
Connection
TubeFemale thread
1H2H
Measuring range Max. operation pressure Contact rating 250 V
2...8 mbar6...75 mbar12...80 mbar12...200 mbar25...220 mbar
50 mbar500 mbar500 mbar500 mbar500 mbar
1 A1 A6 A1 A6 A
008075080200220
Accessories
Covering hood made of plastic DSU 620625000
Order example DSU 625 1 1H 008
Diaphragm
NBRFPMEPDMMVQ
nitrile butadienefluro-elastomerethylene butadienesilicone polymer
1234
Connection
G⅛ AM12 x 1G¼ AG¼ A
AluminiumAluminiumAluminiumBrass
1H2H3H4H
Measuring range pressure Max. operation pressure Contact rating 250 V
2...8 mbar6...75 mbar12...80 mbar12...200 mbar25...220 mbar80...2000 mbar120...2200 mbar1000...6000 mbar
50 mbar500 mbar500 mbar500 mbar500 mbar10000 mbar10000 mbar10000 mbar
1 A1 A6 A1 A6 A1 A6 A6 A
008075080200220020022060
Accessories
Covering hood made of plastic DSU 620625000
301
Order example DSV 625 1 1H 030
Membran
NBRFPMEPDMMVQ
nitrile butadienefluro-elastomerethylene butadienesilicone polymer
1234
Connection
G⅛ AM12 x 1G¼ AG¼ A
AluminiumAluminiumAluminiumBrass
1H2H3H4H
Measuring range vacuum Max. operation pressure Contact rating 250 V
-4...-30 mbar-15...-80 mbar-30...-150 mbar-50...-600 mbar-100...-900 mbar
100 mbar500 mbar500 mbar10000 mbar10000 mbar
1 A6 A6 A6 A6 A
030080150600900
Accessories
Covering hood made of plastic DSU 620625000
302
TEMPERATURE TRANSMITTERS
J Analogue transmitters
J Programmable transmitters
DS_Temperature_transmitters 05/2014
304
ApplicationThe task of electronic transmitters is to ensure that values measured by resistance thermometers, thermocouples or other physical sensors with small output signals are transmitted and displayed without distortion. Undesired distortion due to the connecting cable is, depending on the sensor technology, generally caused by
We transform!
• The ohmic resistance of the supply line (depending on the length, cross-section and temperature)
• Parasitic thermoelectric voltages (at terminals, when using various materials in the connecting cable)
• Electromagnetic interference (caused by machines, high- frequency transmitters, atmospheric pressure discharges, etc.)
Since the increase in interference and instabilities is directly proportional to the length of the connecting cable, the transmitter should be connected directly to the sensor output to ensure that interference to the unamplified signal is kept to a minimum. This requirement is met by so-called “head-mount transmitters”, installed in the (DIN) connection head of the sensor.
-305-305
FunctionTransmitters convert the sensor signal (e.g. resistance change or thermoelectric voltage) into a standardized current or voltage signal. Due to amplification, interference susceptibility is considerably reduced and the length of the cable is irrespective for signal currents. The transmitter is powered via the loop current or an external power supply unit.
Head-mount transmittersThese transmitters are installed directly in the connection head or angle connector of the sensor and guarantee an undistorted measuring signal, even at the end of the connecting cable. SIKA provides transmitters for resistance thermometers and thermocouples for DIN Form B connection head, Form J connection head and angle connector DIN 43650.
Rail-mount transmittersFor switch cabinet installation, SIKA provides transmitters for resistance thermometers and thermocouples, as well as signal converters for current and voltage signals. The transmitters are contained in an extremely compact housing which can be simply clipped on to all commercially available mounting rails.
Special transmittersSince head-mount or rail-mount installation is not always possible or switching outputs are required, SIKA also offers numerous special solutions. Connector-design transmitters are excellent for assembly in tubular housings. Connectors are used widely in the industry. This arrangement ensures cost-effective customized sensors with transmitters.
A relay is required to monitor temperatures or to realize simple controlled systems. A potential-free contact is operated when a freely selectable switching temperature is reached. The switching point and hysteresis can always be set.
305
306
Type MUB 103
Analogue transmitters
Head-mounting
Features
• Direct mounting in head type B
Housing
• Synthetic material polyurethane Ø approx. 44.5 mm, high approx. 26 mm, weight approx. 30 g
Operating temperature
• -25...85 °C
Connection
• Screw terminal (0.13…1.5 mm²)
Technical data For thermocouples For resistance thermometers
Input Type K, J (L), T (U), N, E, S and B Pt100 / Pt1000, 2- or 3-wire (class B)
Measurement current Max. 1 mA
Output / Power supply Type MUB 1014...20 mA, 2-wire / 10...35 VDCType MUB 1020...10 V, 3-wire / 15...35 VDC
Type MUB 1034...20 mA, 2-wire / 10...35 VDCType MUB 1040...20 mA, 3-wire / 18...30 VDCType MUB 1080...10 V, 3-wire / 15...35 VDC
Zero > -270 °C -200...800 °C
Span > 200 °C 20...800 °C
Accuracy < 1 % full scale
Response time < 0.1 sec
307
Type MUJ 143 Features
• Direct mounting in head type J
Housing
• Synthetic material polyurethane Ø approx. 25 mm, high approx. 15 mm, weight approx. 30 g
Operating temperature
• -25...85 °C
Connection
• Screw terminal (0.13…0.75 mm²)
Technical data For thermocouples For resistance thermometers
Input Type K, J (L), T (U), N, E, S and B Pt100 / Pt1000, 2- or 3-wire (class B)
Measurement current Max. 1 mA
Output / Power supply Type MUJ 1414...20 mA, 2-wire / 10...35 VDC
Type MUJ 1434...20 mA, 2-wire / 10...35 VDC
Zero > -270 °C -200...600 °C
Span > 200 °C 20...850 °C
Accuracy < 1 % full scale
Response time < 0.1 sec
308
Type MUS 408
For resistance thermometers (RTD) mounted in angle plug
Features
• Direct mounting in angle plug DIN 43650
Housing
• Transmitter mounted in cutomer specific round housing
• Dimensions of the printed circuit Board 26 x 15.5 x 12.5 mm, weight approx. 10 g
Operating temperature
• -25...85 °C
Connection
• Angle plug DIN 43650
Technical data
Input Resistance thermometers Pt100 / Pt1000 2- or 3-wire
Measuring current Max. 1 mA
Power supply Type MUS 4064...20 mA, 2-wire / 10...35 VDCType MUS 4080...10 V, 3-wire / 10...35 VDC
Sensor connection Solder contacts
Zero -200...800 °C
Span 20...800 °C
Accuracy < 0.1 % full scale
Response time < 0.1 sec
Resistance thermometers with angle plug DIN 43650 in chapter temperature sensors.
309
Type MUS 105
For resistance thermometers mounted in head
Features
• Direct mounting in head type B with adjustable relay output
Housing
• Synthetic material polyurethane Ø approx. 44.5 mm, high approx. 26 mm, weight approx. 40 g
Operating temperature
• -25...70 °C
Connection
• Screw terminal (0.13…1.5 mm²)
Technical data
Input Resistance thermometers Pt100 2-wire
Measurement current Max. 1 mA
Power supply Type MUS 105Potential free relay contact / 10...35 VDC
Setpoint 16 selectable ranges between -200...480 °C
Switching voltage 30 VDC, 250 VAC
Switching current Max. 5 A
Zero -200...800 °C
Span 20...800 °C
Accuracy < 1 % full scale
Response time < 0.1 sec
Resistance thermometers with mounted in head type B in chapter temperature sensors.
310
Programmable transmitters
For Rail-mounting
Type MUTFeatures
• Multifunction input for RTD, TC, mV, V, mA
• Programmable voltage and current output
• Programmable PC Software and DIP switch
• Input and output potential separated
• High accuracy
• Reconfigureable in field applications
Housing
• For rail-mounting according to DIN EN-50022 and EN 50035 112 x 90 x 12.5 mm (H x T x B), weight approx. 90 g
Operating temperature
• -20...60 °C
Supply voltage
• 18…30 VDC
Connection
• Screw terminal (0.13...1.5 mm²)
Technical data
Typ Measuring range Min. Span
Output MUT 4531 A, MUT 4531 B, MUT 4531 C
Current 0(4)...20 mA 4 mA
Voltage 0...10 V 1 V
MUT 4135
Current 0(4)...20 mA20...0(4) mA
4 mA4mA
Voltage 0...10 V10...0 V
1 V1 V
Other data
Load Max. 1000 Ω at 30 V
Linearity Resistance thermometer ±0.1 % full scaleThermocouples ±0.2 % full scale
Temperature drift 0.01 % / °C full scale
Program Configuration for cutomer specification or via PC-interface with SIKA-Prosoft software
311
Technical Data
Typ Measuring range Min. Span
Input MUT 4531 A
ThermocouplesJ JJ KJ SJ R J BJ EJ TJ N
-200...1200 °C-200...1300 °C0...1750 °C0...1750 °C0...1850 °C-200...1000 °C-200...400 °C-200...1300 °C
100 °C100 °C400 °C400 °C400 °C100 °C100 °C100 °C
VoltageJ mVJ mVJ mV
-100...90 mV-100...200 mV-100...800 mV
5 mV10 mV20 mV
MUT 4531 B
Resistance thermometerJ Pt100J Pt1000J Ni100J Ni1000
-200...850 °C-85...185 °C-60...180 °C-60...150 °C
50 °C30 °C50 °C30 °C
Resistance 0...500 Ω0...2000 Ω
50 Ω50 Ω
MUT 4531 C
PTCJ KTY81-210J KTY81-220J KTY84-130J KTY84-150
-55...150 °C-55...150 °C-40...300 °C-40...300 °C
50 °C50 °C50 °C50 °C
NTCJ 10KJ 1K
-10...100 °C-30...40 °C
50 °C25 °C
Potentiometer (<50 KΩ) 0...100 % 10 %
Technical Data
Typ Measuring range Min. Span
Input MUT 4135
ThermocouplesJ JJ KJ SJ R J BJ EJ TJ N
-200...1200 °C-200...1370 °C0...1760 °C0...1760 °C0...1820 °C-200...1000 °C-200...400 °C-200...1300 °C
100 °C100 °C400 °C400 °C400 °C100 °C100 °C100 °C
VoltageJ mVJ mVJ mV
-400...400 mV-400...700 mV-10 000...10 000 V
2 mV2 mV500 mV
Resistance thermometerJ Pt100J Pt1000J Ni100J Ni1000
-200...850 °C-200...200 °C-60...180 °C-60...150 °C
50 °C50 °C50 °C50 °C
Resistance 0...300 Ω0...2000 Ω
10 Ω0...200 Ω
Potentiometer 0...200 Ω200...500 Ω0.5...50 KΩ
10 %10 %10 %
Current -10...24 mA 2 mA
Technical Data
Accessories
Extensive SIKA Prosoft software is available to program the MUT transmitter series. Can be easily user configured via a PCinterface at an external computer.
SIKA Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7-9 34260 Kaufungen / Germany
Phone +49 5605 803-0 Fax +49 5605 803-54
Email: [email protected] www.sika.net
Mechanical Measuring Instruments
Flow Measuring Instruments
Electronic Measuring and Calibration Instruments
2014 Edition
Subject to technical modifications and errors
KAT600ELE00ENG