Size (mm)2.5~1010~2525~4050~80100100~150150~250300350~10001000~3000

InstallationWaferFlangeSanitary (clamps, unions)

Temp. (˚C)-60~-25-25~-20-20~-5-5~00~+60+60~+90+90~+100+100~+120+120~+140+140~+180

Max.Press. (MPa)≤1≤1.6≤4>4

Conductivity≥0.05µS/cm≥5µS/cm

Liner materialCeramicTeflonRubberPolypropylene

ElectrodesHastelloy CPlatinumOthers

Protection type

CENELEC certifiedTIIS certified

Current outputDC4-20mA/0-20mAOthers

Pulse output≤10Hz (Scaled pulse)

Status output (Flow alarm, others)1 output2 outputs

Control input (Counter reset, others)Input

Communication functionHART communication

ApplicationPotable water, SewageChemicalsLow conductivityAdhesive liquidSlurryHigh concentration slurry

Paper, PulpPulsating flowBatch processHigh press.Sanitary process

EGM1010C

EGM4010C

EGM2010C

EGM5010C

EGM6010C

EGM5015C

EGM1300C

EGM4300C

EGM2300C

EGM5300C

MGM5090K-CAP

EGM6300C

10 Series 300 Series

Compact versionsS

EL

EC

TI

ON

GU

ID

AN

CE

MAGMAXSelection guide

Size (mm)2.5~1010~2525~4050~80100100~150150~250300350~10001000~3000

InstallationWaferFlangeSanitary (clamps, unions)

Temp. (˚C)-60~-25-25~-20-20~-5-5~00~+60+60~+90+90~+100+100~+120+120~+140+140~+180

Max.Press. (MPa)≤1≤1.6≤4>4

Conductivity≥0.05µS/cm≥5µS/cm

Liner materialCeramicTeflonRubberPolypropylene

ElectrodesHastelloy CPlatinumOthers

Protection typeTIIS certifiedCENELEC certified

Current outputDC4-20mA/0-20mA

OthersPulse output

≤10Hz (Scaled pulse)

Status output (Flow alarm, others)1 output2 outputs

Control input (Counter reset, others)Input

Communication functionHART communication

ApplicationPotable water, SewageChemicalsLow conductivityAdhesive liquidSlurry

High concentration slurryPaper, PulpPulsating flowBatch processHigh press.Sanitary process

EGS1000F

EGS4000F

EGS2000F

EGS5000F

EGS6000F

EGC010W

EGC300F

EGC300W

Primary head (Detector)

Separate versionsConverter (Electronics)

**

**

**

**

**

* Subject to converter performance and specification

EGM1010C

EGM5010C

EGM2010C

EGM6010C

EGM4010C

Primary head (detector) and converter(electronics) are integrated in one unit for easyinstallation, wiring and saving space.Two versions of converter unit are ready tochoose;

10 series Light weight plastic electronics housing,Price effective!

300 series Aluminum alloy housing with highperformance!

COMPACTVersions

Easy installation and wiringEasy installation and wiring

Size 10,15,25,40,50,80,100,150mmPress. 1.6MPa Max.Temp. -25~+120˚CMaterial Liner : PFA

Electrodes : Hastelloy CInstallation Wafer type

Economy and Ecology,Easy use

Size 10,15,25,40,50,65,80,100,125,150,200,250,300,350···1000mm

Press. 150MPa Max.Temp. -25~+120˚CMaterial Liner : PFA/PTFE/ETFE/Polyurethane rubber

Electrodes : SS316,HastelloyB/C,Tantalum,Platinum,Others

Installation Flange connection

Various liners andelectrode materialscovering a wide range ofapplications!

Size 25,40,50,65,80,100,125,150,200,300,350···1000mmPress. 15MPa Max.Temp. -5~+90˚CMaterial Liner : Polypropylene/Hard rubber

Electrodes : Hastelloy CInstallation Flange connection

Polypropylene/Hardrubber liner & Low price.Most suitable for thesewage and potable water

Size 2.5,4,6,10,15,25,40,50,80,100mmPress. Size 2.5~80mm : 4MPa Max.

Size 100mm : 1.6MPa Max.Temp. -25~+120˚CMaterial Measuring tube Size 2.5~15mm : Zirconia ceramics

Size 25~100mm : Alumina ceramicsElectrodes Size 2.5~15mm : Pt.CERMET

Size 25~100mm : PlatinumInstallation Wafer type

The original ceramic tubenow improved beyondthe reach of competitors.

Size 10,15,25,40,50,65,80mmPress. 4MPa Max.Temp. -25~+140˚CMaterial Liner : PFA (FDA approved)

Electrodes : SS316,Hastelloy C,OthersFittings : Stainless steel (SS304 or SS316)

Installation Sanitary clamps, unions (IDF,others)

For foods, pharmaceuticalapplicationsFDA approved PFA liner

EGM1300C

EGM4300C

EGM6300CEGM5300C

EGM2300C

Size 10,15,25,40,50,80,100,150mmPress. 1.6MPa Max.Temp. -25~+120˚CMaterial Liner : PFA

Electrodes : Hastelloy CInstallation Wafer type

Standardized with PFA liner andHastelloy C electrodes. Low cost and high performanceare realized.

Size 25,40,50,65,80,100,125,150,200,250,300,350···1000mm

Press. 15MPa Max.Temp. -5~+90˚CMaterial Liner : Polypropylene/Hard rubber

Electrodes : Hastelloy CInstallation Flange connection

Low cost and generalpurpose typeFor air conditioning andsewage applications

Size 10,15,25,40,50,65,80,100,125,150,200,250,300,350···1000mm

Press. 150MPa Max.Temp. -40~+140˚CMaterial Liner : PFA/PTFE/ETFE/Polyurethane rubber

Electrodes : SS316,HastelloyB/C,Tantalum,Platinum,Others

Installation Flange connection

The standardelectromagnetic flowmeter!Wide variation of liner andelectrode material

Size 2.5,4,6,10,15,25,40,50,80,100mmPress. Size 2.5~80mm : 4MPa Max.

Size 100mm : 1.6MPa Max.Temp. -60~+140˚CMaterial Measuring tube Size 2.5~15mm : Zirconia ceramics

Size 25~100mm : Alumina ceramicsElectrodes Size 2.5~15mm : Pt.CERMET

Size 25~100mm : PlatinumInstallation Wafer type

The new generation ofceramic tubeelectromagnetic flowmeterthat Tokyo Keiso offerswith absolute confidence!

Size 10,15,25,40,50,65,80mmPress. 4MPa Max.Temp. -40~+140˚CMaterial Liner : PFA (FDA approved)

Electrodes : SS316,Hastelloy C,OthersFittings : Stainless steel (SS304 or SS316)

Installation Sanitary clamps, unions (IDF,others)

Easy installation andremoval from processlines with IDF clamp /union connection.Best for foods andpharmaceuticalprocesses

EGC300W EGC300F EGC010W

Primary head

Primary head (detector) and converter(electronics) are separated.This version is suitable for ;

• Remote indication at separate location• High temperature circumstance• Strong process pipe vibration• Underground pit with possibility of

submersion,etc.

For underground pits, overhead lines and high temp. lines, etc.For underground pits, overhead lines and high temp. lines, etc.

SEPARATEVersions

Standardconverter withfull functions

Unique compactdesign converterWall or 2-inchpipe mount

Easy installation ontowall with compacthousing

Converter

EGS1000F

EGS2000F

EGS5000F

EGS4000F

EGS6000F

Size 25,40,50,65,80,100,125,150,200,250,300,350···1000mm

Press. 15MPa Max.Temp. -5~+90˚CMaterial Liner : Polyproplene/

Hard rubberElectrodes : Hastelloy C

Installation Flange connection

For sewage,water and hot water.Low cost and general purpose type

Size 10,15,25,40,50,80,100,150mm

Press. 1.6MPa Max.Temp. -25~+120˚CMaterial Liner : PFA

Electrodes : Hastelloy CInstallation Wafer type

PFA liner with Hastelloy Celectrodes!

Size 10,15,25,40,50,65,80,100,125,150,200,250,300,350···1000mm

Press. 150MPa Max.Temp. -40~+180˚CMaterial Liner : PFA/PTFE/ETFE

Polyurethane rubberElectrodes : SS316,Hastelloy B/C

Tantalum,Platinum,OthersInstallation Flange connection

The standard primary head Wide selection of liners andelectrodes

The new generation of ceramic tube!

Size 2.5,4,6,10,15,25,40,50,80,100mm

Press. Size 2.5~80mm : 4MPa Max.Size 100mm : 1.6MPa Max.

Temp. -60~+180˚CMaterial Measuring tube Size 2.5~15mm : Zirconia ceramics

Size 25~100mm : Alumina ceramicsElectrodes Size 2.5~15mm : Pt.CERMET

Size 25~100mm : PlatinumInstallation Wafer type

Size 10,15,25,40,50,65,80mmPress. 4MPa Max.Temp. -40~+180˚CMaterial Liner : PFA (FDA approved)

Electrodes : SUS316,Hastelloy C,Others

Fittings : Stainless steel(SS304 or SS316)

Installation Sanitary clamps, unions(IDF,others)

Sanitary primary head

EGM5015C

MGM5090K-CAP

MGM4090K-JEx/EEx MGM5090K-JEx/EEx

and high temp. lines, etc.and high temp. lines, etc.

EEx dq [ib] llC T3···T6(EEx)Ex ds [ib] llC T4(JEx)

10mm~300mm

EEx dme [ib] llC T3···T6(EEx)Ex dse [ib] llC T4(JEx)

2.5mm~100mm

PROTECTION Versions

Capacitance detection type NON CONTACT ELECTRODE Version

Thanks to new non contact electrode design, it is nowpossible to measure very low conductivity liquids, highconcentrated slurries and very adhesive liquid.

•Size 25,40,50,80,100mm

•Press. 4MPa Max.

•Temp. -25~+100˚C

•Material Measuring tube : Ceramic

•Installation Wafer type

•Type of protection EEx d llC T4···T6(EEx)Ex d llC T4(JEx)

FILLER FLOWMETER

•Size 2.5,4,6,10,15,25,40mm

•Press. 4MPa Max.

•Temp. -60~+140˚C

•Material Measuring tubeSize 2.5~15mm Zirconia ceramicsSize 2.5~40mm Alumina ceramics

ElectrodesSize 2.5~15mm PT.CERMETSize 2.5~40mm Platinum

•Construction IP67

Electromagnetic flowmeter forbottle or can filler machines.Aiming for high speed filling.Compact and high accuracy!

Diam

eter

2.5m

m

1/10

"

4mm

1/8"

6mm

1/4"

10mm

3/8"

15mm

1/2"

25mm

1"

50mm

2"

80mm

3"

100m

m

4"

150m

m

6"

200m

m

8"

250m

m

10"

300m

m

12"

350m

m

14"

400m

m

16"

500m

m

20"

40mm

11 / 2

"

32 4

12111098765

4

3

2

1

0.5�

0.30.01 2

2 3 4 5 6 7 8919 0.1 2 3 4 5 6 7 89 2 3 4 5 6 7 8 2 2 2 3 L/min3 4 5 6 7 89103 4 5 6 7 891091010

3 4 5 6 7 89 2 3 4 5 6 7 891 2 3 4 5 6 7 89 2 3 4 5 6 7 8 2 3 4 5 6 7 8 910 m3/h910 100.10 5 6 7 8 9 2 3

Flow rate

m/s

Flo

wve

loci

ty

SIZE SELECTIONFlow rate-velocity table

•Full scale of flowmeter can be set between 0.3~12 m/s velocity.Find the required full scale flow rate at the horizontal axis and trace shit vertically upward. The flowmeters of which red linecrosses such vertical line can be selected.

Head Office : Shiba Toho Building,1-7-24 Shibakoen, Minato-ku, Tokyo 105-8558Tel : 03-3431-1625(KEY) ; Fax : 03-3433-4922e-mail : [email protected] URL : http://www.tokyokeiso.co.jp

*Specification is subject to change without notice.

No.PH-EF101-2EMAR. 2007

Individual catalogues or technical guidances are available for all the products introduced in this guidance.Contact your agent or TOKYO KEISO.