electroanalytical tools for (bio)sensors 14.04.04 ... · advantages of dc amperometric...
TRANSCRIPT
![Page 1: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/1.jpg)
ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS
14.04.04 Wednesday: 1015 - 1200 (Classroom 300, Main Building)
"Amperometric detection on solid state electrodes. General."
Which organic substances can be detected withamperometric sensors and why? How do these sensors work?
![Page 2: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/2.jpg)
- DC Amperometry, Voltammetry
- Potentiometry
- Conductivity
- Tensammetry (double layer capacitance)
- Spectroelectrochemical
Electrochemical sensors:
+++
---
potentiometry
![Page 3: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/3.jpg)
electronics and electrolytics...
(amperometry)
potentio conductivity (Royce Rocklin, Dionex)
![Page 4: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/4.jpg)
amperometric sensors: working principle
1 potentiostat
2 counter electrode
3 working electrode
4 reference electrode
1
23
4
![Page 5: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/5.jpg)
counter electrode
workelectrode
iout
ref. el.
Ework (vs. ref.)
Ew + Er
potentiostat electronics
operational amplifiers as current follower or as voltage follower
![Page 6: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/6.jpg)
amperometry in hydrodynamic conditions
hydrodynamic voltammogram
current
diffusion limited current
e-
O
Rpotential
0 +500 mV vs Ag/AgCl
![Page 7: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/7.jpg)
amperometry in hydrodynamic conditions
Matsuda’s equation for the limiting current il for a wall-jet:
il = cst.c0. Fm3/4.D2/3.γ -5/12.a-1/2.r3/4
current
r
a
il
0 +500 mV
![Page 8: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/8.jpg)
current, i100% O
potential
100% R
0 +500 E, mV
il
E1/2
OR
nEE log059.0
2/1 −=
![Page 9: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/9.jpg)
current, i
il
1 2
0 500 E, mV
(1) Easily oxidizable compound.
(2) More difficult to oxidize compound.
'0
2/1 lnDD
nFRTEE −=
![Page 10: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/10.jpg)
current, i
1 2 3il
0 +500 E, mV
1 fast kinetics
2 slow kinetics
3 background
![Page 11: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/11.jpg)
Most popular electrode materials
Glassy carbon, carbon paste, Pt, Au
![Page 12: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/12.jpg)
B
oxacilline a thiaridazine b narcotine c desipramine d levomepromazine e chloropromazine f carbenicilline g amilaride h triamtereen i codeine j papaverine k amytriptiline l
Aparacetamol a procaine b salicylamide c sulphadiazine d sulphanilamide e diethylstibestrol f oxprenolol g
![Page 13: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/13.jpg)
• Amperometric detection coupled to LC
![Page 14: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/14.jpg)
• Setup in lab
![Page 15: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/15.jpg)
• Home-made large volume wall-jet cell and electrodes
Glassy carbon (left), glassy carbon with coating (right)
![Page 16: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/16.jpg)
0 10 20 min
A classical HPLC application:
catecholamines
1 norepinephrine
2 epinephrine
3 3,4 dihydroxybenzylamine
4 dopamine
5 serotonine
6 5-hydroxyindoleacetic acid
7 homovanillic acid
reversed phase, D.C. amp., glassy carbon, +0.8V(AgCl), phosphate buffer pH 3, gradient 5% to 56% methanol
![Page 17: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/17.jpg)
Is rapid on-line scanning, or the use of multiple electrode systems possible in HPLC, to obtain 3D chromatograms?
![Page 18: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/18.jpg)
low scan-rate
high scan-rate
![Page 19: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/19.jpg)
when scan-rates increase, the "hydrodynamic" character decreases
![Page 20: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/20.jpg)
Amperometry in non-hydrodynamic conditions
When there is no eluent flow, we scan the potential. Most popular: cyclic voltammetry. It tells us how molecules behave in amperometry.
![Page 21: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/21.jpg)
![Page 22: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/22.jpg)
O
OH
COOHH2N
O
O
+ + 2e- + H+
O
O
OH
OH
COOH
NH2
A
C
D
![Page 23: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/23.jpg)
NO2
NHCOCHCl2
OH
OH
chloramphenicol
![Page 24: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/24.jpg)
NO2 NH OH
+ H2O4H+ + 4e- +
NO
+ 2H+ + 2e-
A
B C
2/12/12/10 .)(....45.0 DSRTnFcAFnip =
![Page 25: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/25.jpg)
less common: reductive mode HPLC detection
-500mV(SCE)
benzoquinone
2-OH naphtoquinone
juglonevitamin K
![Page 26: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/26.jpg)
Other characteristics of amperometric detectors:
- Response time (below 1s)
- Coulometric efficiency (around 1% for wall-jet to 100% for porous electrodes)
- Interelectrode variation (36% for GC, n=10, own data)
![Page 27: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/27.jpg)
Is your compound a candidate for DC amperometric detection?
See internet: amperometric (electrochemical), + compound name
See also internet pages with applications, from equipment manufacturers Dionex, Antec, MetrOhm, BAS, Coulochem..
Check it with cyclic voltammetry
Try it with a simple FIA experiment
![Page 28: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/28.jpg)
OH
OH
OH
OH
O O
HO O
OH
HO
phenolics,
hydroxycoumarins, flavones..
![Page 29: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/29.jpg)
HO
O
HO
OEstrogens
Tocopherols
![Page 30: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/30.jpg)
NH2
NH2H2N
H2N SO2NH-RN
H
S
N
R
R-SH
RHO
OH
anilines, benzidines
sulfonamides
indolyl-3
5-hydroxyindoles
phenothiazines
mercaptans
vitamin A, carotenes
![Page 31: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/31.jpg)
O
O
OH
HO
OH
HO
R-SH R-S-S-R
redox status indicators for extra- and intracellular fluids: vitamin c and glutathion
![Page 32: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/32.jpg)
NO2 NH OH
+ H2O4H+ + 4e- +
reductive measurements: aromatic nitro- and nitroso-compounds
HN
OH
+ 2H+ + 2e-
NH2
+ H2O
problems: oxygen
![Page 33: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/33.jpg)
NH2
![Page 34: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/34.jpg)
Advantages of DC amperometric (electrochemical) detection in HPLC:
- Very sensitive. In HPLC: low pg levels
- Linear calibration curves over wide range
- Selective
- Cheap
Disadvantages in HPLC:
- Electrodes are surfaces. Surfaces are variable and require experience in handling
- Reference electrodes and air bubbles can give high impedances.
![Page 35: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/35.jpg)
What about the use of DC amperometry in CE and lab-on-chip?
Tanyanyiwa, J.; Leuthardt, S.; Hauser, P. C. Electrophoresis2002, 23, 3659-66.Some 90references on conductivity plus potentiometry in CE and microchip capillary. Mostly conductivity.
Wang, J. Talanta 2002, 56, 223-3123 applications of amperometry in miniaturized separation systems from 1998 to 2001.
![Page 36: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/36.jpg)
Amperometric sensors and microsensors for use in physiology, biomedical, cell cultures, bioreactors..Examples for NO:
Source: World Precision Instruments, Lab Equipment for the life sciences, catalog 2004. www.wpi-europe.com
![Page 37: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/37.jpg)
Source: World Precision Instruments, Lab Equipment for the life sciences, catalog 2004. www.wpi-europe.com
![Page 38: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/38.jpg)
Sensor surface uncovered Sensor surface covered with permselective membrane
Example: keeping dopamine out with an anion exchanger membrane
![Page 39: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/39.jpg)
small molecules, ions
minerals, bioparticles,..proteins,
oligosacharides, oils in micelles..
![Page 40: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/40.jpg)
colloidal systems like blood contain enzymes which provoke blood clotting (thrombosis) when sensors are inserted.
![Page 41: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/41.jpg)
Is in-vivo monitoring possible with (amperometric) sensors?
No, lipophilic sensor surfaces provoke blood clots within seconds to hours →thromboses.
And matrix too complex! Interferences unless biosensor is used!
Thrombocytes (platelets). Smallest cellular component of blood. 250,000 per cubic mm.They secrete the protein fibrinogen. Platelets, red and white blood cells get trapped infibres.
![Page 42: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/42.jpg)
Solutions eg for potentiometric sensors:
- Use hydrophilic materials for sensors (eg polyurethanes), or use techniques from leech: NO as anticoagulant + anaesthetic
Solutions for amperometric sensors:
- Do sampling with microdialysis, and analysis with µLC and ECD. Or use biosensors (glucose, urea).
![Page 43: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/43.jpg)
membranes
water………….solution………..colloïdal……….suspension
semi-permeable membrane
dialysis membrane
osmosis membrane filter
![Page 44: ELECTROANALYTICAL TOOLS FOR (BIO)SENSORS 14.04.04 ... · Advantages of DC amperometric (electrochemical) detection in HPLC: - Very sensitive. In HPLC: low pg levels - Linear calibration](https://reader034.vdocuments.mx/reader034/viewer/2022042122/5e9c6913b301ae1b9c72e2c8/html5/thumbnails/44.jpg)
to HPLC/ECD
microdialyse vanextracellulaire vochten(bloed, planten..)
0,1mm
microdialysis probe