Page 1: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

ELECTRICALVEHICLE

CHARGERS

Page 2: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770
Page 3: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Roaming Networks is one of the leading system integrators in Serbia and the Balkan region. We provide professional consulting, design, implementation, integration and maintenance services in the areas of radio communications, passive optical networks, ICT infrastructure and Data centers and Technical Protection and Automatic Control Systems.

In its portfolio of services, it has also included the provision of ready-made, complete solutions for charging electric vehicles - from compact, high-quality wall chargers for AC charging, reliable DC fast chargers, to innovative charging systems for electric buses on your request. We offer professional consulting, design, implementation, integration and maintenance of vehicle charging systems. We provide and deploy infrastructure that meets the needs of the

new generation of smart mobility, and our goal is to make such mobility

sustainable and accessible to everyone and everywhere.

By introducing innovative solutions for charging electric vehicles and modernizing processes, Roaming Networks has laid the foundation for smart, reliable environmental mobility of vehicles, without emissions and thus confirmed that it is a dynamic and innovative company which

operates responsibly towards society and the environment.

1

Page 4: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

General specifications:

1a CAR ChARGERS - AC ChARGERS I Terra AC wall charger

Product information

Charging type

Input/output power rating and current

Input/ouput voltage

Network typeSocket outlet or connector type

Protection

Overvoltage categoryEnergy metering

Mobile communication with nano SIM socketAvailable configurable contacts

Mode 3 charging, level 2 IEC ratings: Single phase up to 7.4 kW / 32 A Three phase up to 22 kW / 32 AUL ratings up to 19 kW / 80 ASingle phase: 110 … 240 VThree phase: 380 … 415 V, 50 / 60 HzTT, TN, ITType 2 socket with or without shutterType 1 or type 2 cable. Cable can be wrapped around the chargerOvercurrent, overvoltage, undervoltage, ground fault including DC leakage protection, integrated surge protectionIIIRevenue grade energy meter Class B (+/- 1%) , MID certification on display variants onlyEU: GSM, 4G, LTE, WCDMA US: 4G, LTE, WCDMA1 input, 1 output

2

Page 5: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

General characteristics

Certification and standards

Lifetime

IP and IK rating

NEMA enclosure typeOperating altitudeOperating temperature rangeStorage temperature rangeMountingDimensions H x W x D H x W x D

Safety standards

Codes and standards

CertificationWarranty

10 years. 16 h charging, 8 h standby, 5 charge sessions per dayIP54, IK10 (IK8+ for operating temperature from -35 to -30 °C)NEMA 4 and 4X4000 m-35...+50 °C (derating may apply)-40...+80 °CWall or floor using a pedestal320 x 195 x 110 mm12.60 x 7.68 x 4.33 inches

IEC/EN 61851-1, IEC/EN 62311, IEC/UL 62479, IEC/UL 62955TuV listed conforming to UL 2594, UL 2231-1, UL 2231-2, UL 1998, CSA C22.2. NO.280IEC 61851-21-2, EN 61000 -6 -1, EN 61000 -6 -2, EN 61000 -6 -3, EN 61000 -6 -4, EN 61000 -3-2, EN 61000 -3-3, EN 61000 -3-11, EN 61000 -3-12CE RED - WL AN / RFID / E-UTR A: EN 300 328 V2.1.1, EN 300 330 V2.1.1, EN 301 908-1 V11.1.2, EN 301 908-13FCC Part 15 Class BENERGY STARCE, CB, MID, UL24 months

3

Page 6: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specification:

1bProduct information

DC output powerDC output voltageDC output currentUser interfaceRFID system

Network connection

EnvironmentOperating temperature

ProtectionDimensions (H x W x D)Charge cableMass

24 kW peak - 22.5 kW continuous150 - 920 VDC

60 A7” full color touchscreen displayISO/IEC14443A/B, ISO/ IEC15693,NFC reader mode, Mifare, CalypsoGSM / 3G modem10/100 Base-T EthernetIndoor / outdoor-35 °C to +55 °C(de-rating characteristic applies)IP54, indoor and outdoor770 x 584 x 300 mmcable lengths 3.5 or 7 m60kg excluding backplate(10 kg) and cables

4

CAR ChARGERS - DC ChARGERS I Terra DC wallbox 24 DC

Page 7: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

CE models

Charging protocols

AC Input power connectionInput voltage rangeMax. rated input current

Efficiency

Compliance and safety

CCS 2CHAdeMO3P + N + PE400 VAC +/-10 % (50/60 Hz)3 x 40 ACurrent limiting options available94 % at nominal outputpowerCEEMC Class A today,EMC Class B Q3 2019

5

Page 8: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specification:

Optional models: Terra 94 DC/ Terra 124 DC/ Terra 184 DC

CAR ChARGERS - DC ChARGERS I Terra 54 DC

General specifications

Grid Interface

Charging sessions

EfficiencyEMC emissionEMC immunityEnvironment of useProtection ratingOperating temperatureDimensions (D x W x H)Mass

Input AC power connectionInput voltage rangeMax. rated input current &power (@ 50 Hz)

Power factor (full load)THD in all operating pointsOperating Noise level

1 DC session1 DC & 1 AC session (G & T models)94 % at nominal output powerIEC 61000-6-3 Class B - ResidentialIEC 61000-6-2 IndustrialIndoor / outdoorIP54, IK10 (cabinet), IK8 (screen)-35 °C to +55 °C (de-rating characteristics apply)780 mm x 565 mm x 1900 mm350 kg

3 Phases + Neutral + PE400 V

AC +/- 10 % (50 Hz or 60 Hz)C, CJ : 80 A, 55 kVACT, CJT : 112 A, 77 kVACJG, CG : 143 A, 98 kVA> 0.96< 4.5 %< 60 dBA

6

Page 9: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

User & Network Interfaces

Options

Outlet specifications C (default) J (option) G (option) T (option)

ScreenRFID systemNetwork connection

Communication protocol

Local payments

Power meterCable management system

Charging standardMaximum output powerOutput voltage Terra 54Output voltage Terra 54HVMaximum output currentConnector/socket typeCable length

CCS

50 kW

150 - 500 VDC

150 - 920 VDC

125 ADC

CCS 2 / IEC 62196 Mode-4

3.9 m

CHAdeMO 2.0

50 kW

150 - 500 VDC

150 - 500 VDC

125 ADC

CHAdeMO 2.0 / JEVS G105

3.9 m

Type 2 cable

22 or 43 kW

400 V +/- 10%

400 V +/- 10%

63 A

IEC62196 Mode-3 Type-2

3.9 m

Type 2 socket

22 kW

400 V +/- 10%

400 V +/- 10%

32 A

IEC62196 Mode-3 Type 2

7” touchscreenISO/IEC 14443A/B, ISO/IEC 15393Cellular modem: GSM / 3G / 4G LAN: 10/100 Base-T EthernetOpen Charger Point Protocol (OCPP) 1.6(and previous versions)

Credit Cards and NFC (including Apple Pay)readerDC & AC certified metersCharger prepared for CMS installation

7

Page 10: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specification:

CAR ChARGERS - DC ChARGERS I Terra HP

General specifications

Charge post

Compliance and certificationEnvironmentMechanical impact protectionOperating temperature

DC output current

DC output voltage rangeUser interfaceLights

RFID

Network connections

Dimensions (H x W x D)Weight

CE models and UL models availableIP 54, outdoor useIK 10 (screen: IK 08)-35 °C to +55 °C (with derating)

500 A CCS (liquid cooled)200 A CHAdeMO150 – 920 V

DC

7” high brightness touch screenRGB led strips with customizable colors White top lightISO/IEC 14443A/B, ISO/IEC 15393,FeliCa™1, NFC, Mifare, Calypso, (option: Legic)GSM/2G/3G10/100 base-T Ethernet2390 x 620 x 440 mm250 kg

8

Page 11: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Power cabinet

Output power per power cabinet

AC Input – CE models

AC Input – UL models

Efficiency (full load)Power factorEMC emission

Dimensions (H x W x D)Weight

175 kW peak160 kW continuous (375 A)400 VAC ±10%, 50 Hz3P + PE (no neutral)277 A nominal @400 VAC

(160 kW output)308 A peak @360 VAC

(175 kW output)480 VAC ±10%, 60 Hz3P + PE (no neutral)215 A nominal @480 VAC

(160 kW output)272 A peak @432 VAC

(175 kW output)≥ 94% at full load≥ 0.97Standard: Class A (industrial)Optional: Class B (residential)with external filter2030 x 1170 x 770 mm1340 kg

175 kW 375 A150-920 VDC

9

Page 12: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Connector specification:

1c

Technical specifications

PowerInput AC connectionRated input current & power (per 150 kW module)Input voltage rangeMaximum output current (per 150 kW power cabinet)Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature

Dimensions (W,D,H)

100 kW, 150 kW3P + PE100 kW: 3 x 170 A, 117 kVA150 kW: 3 x 250 A, 173 kVA400 V

AC +/-10% (50 Hz or 60 Hz)100 kW: 166 A150 kW: 200 A (limited by CCS cable)150- 850 V DC

IEC 61851-23 / DIN 70121/ ISO 15118CCS 1 or CCS 2lndoor / OutdoorStandard: -10 °C to +SO °C Optional: -35 °C to + 50 °CPower cabinet: 1170 x 770 x 2030 mmDepot eh arge box: 600 x 220 x 800 mm

CHARGERs fOR HEAVy COmmERCIAL VEHICLEsI model - HVC 100C/150C

10

Page 13: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specifications

Network connection

Protection

Sequential chargingCable length between depot charge box and cabinetCable length between 2 depot charge boxesCable length connector

GSM / 3G modern10/100 base-T EthernetCharge cabinet: IP54- IK10Depot charge box: IP65- IK10Yes, up to 3 outlets per chargerUp to 150 m

Up to 30 mStandard: 3.5 mOptional: 7 m

11

Page 14: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

12

Page 15: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specification:

Pantograph Down Specification – Overnight & Opportunity Charging

CHARGERs fOR HEAVy COmmERCIAL VEHICLEsI model HVC 150PD/300PD/450PD/600PD

General specifications

PowerInput AC connectionRated input current & power (per 150 kW power cabinet)Input voltage rangeMaximum output current (per 150 kW power cabinet)Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature

Dimensions (W,D,H)

Network connection

Protection

150 kW, 300 kW, 450 kW, 600 kW 3P + PE3x 250 A, 173 kVA

400 V AC +/- 10% (50 Hz or 60 Hz)

250 AMax is 600 A (limited by pantograph)150-850 V DC

IEC 61851-23 / OppCharge4-pole automatic connection systemlndoor / OutdoorStandard:-10 °C to +50 °C Optional: -35 °C to + 50 °CPower cabinet : 1170 x 770 x 2030 mmPole: 4850 x 1060 x 5820 mmGSM / 3G modern10/100 base-T EthernetIP54- IK10

13

Page 16: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specification:

Pantograph Up Specification – Opportunity Charging

CHARGERs fOR HEAVy COmmERCIAL VEHICLEsI model - HVC 150PU/350PU/450PU/600PU

General specifications

PowerInput AC connectionRated input current & power (per 150 kW power cabinet)Input voltage rangeMaximum output current (per 150 kW power cabinet)Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature

Dimensions (W,D,H)

Network connection

ProtectionCable length between power cabinet and pole

150 kW, 300 kW, 450 kW, 600 kW 3P + PE3x 250 A, 173 kVA

400 V AC +/- 10% (50 Hz or 60 Hz)

250 AMax is 600 A (limited by contact hood)150-850 V DC

IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact domelndoor / OutdoorStandard: -10 °C to +50 °C Optional: -35 °C to + 50 °CPower cabinet : 1170 x 770 x 2030 mmPole: 4850 x 1060 x 5820 mmGSM / 3G modern10/100 base-T EthernetIP54- IK10Up to 100 m

14

Page 17: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Technical specification:

Pantograph Up Specification – Overnight Charging

General specifications

PowerInput AC connectionRated input current & power

Input voltage rangeMaximum output current

Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature

Dimensions (W,D,H)

Network connection

Protection

Sequential charging Cable length between power cabinet and contact domeCable length between 2 contact domes

50 kW, 100 kW, 150 kW 3P + PE50 kW: 3x 80 A, 55 kVA100 kW: 3x 170 A, 117 kVA150 kW: 3x 250 A, 173 kVA400 V

AC +/-10 % (50 Hz or 60 Hz)50 kW: 125 A100 kW: 166 A150 kW: 250 A150- 850 V DC

IEC 61851-23 / DIN 70121/ ISO 151184-pole contact domelndoor / OutdoorStandard:-10 °C to +50 °C Optional: -35 °C to + 50 °C50 kW power cabinet: 325 mm x 770 mm x 1300 mm100-150 kW power cabinet: 1170 x 770 x 2030 mmControl box: 600 x 600 x 250 mmGSM / 3G modern10/100 base-T EthernetCharge cabinet: IP54-IK10Control box: IP65-IK10Yes, up to 3 outlets per chargerUp to 150 mUp to 30 m

15

Page 18: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

16

Page 19: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

General specifications:

CAR ChARGERS - AC ChARGERS I sicharge CC AC22

Product information

Charging connections

EfficiencyCharging processes

Environment of useProtection ratingOperating temperatureDimensions (H x D x W)MassInput AC power connectionInput voltage rangeMax. rated input current &power (@ 50 Hz)

DisplayRFID systemNetwork connectionCommunication protocol

AccountingPower meterFlexible connected load

2 x AC 22 kW, type 294 % at nominal output powerCharging mode according to IEC 61851 “Mode 3”, charging current regulationIndoor / outdoorIP54, IK10-25 °C to +50 °C1700 mm x 390 mm x 194 mm75 kg3 Phases + Neutral + PE230/400 V

AC, 50 Hz, 63AMain switch with fuses 63A, 3P+NMCB, 2x32A, 3P+N B type RCD, In 30 mA, with monitoring functionTFT LED 7“ color with pushbuttonISO 14443Connection via GPRS, UMTS and LTEOpen Charger Point Protocol (OCPP) 1.6(and previous versions)Accounting possible via backend systemBasic MID meterStatic load managementBackend-side load management (OCPP 1.6)

17

2a

Page 20: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

General specifications:

CAR ChARGERS - DC CHARGERs I CPC 50

Product information

Charging connections

EfficiencyNoise level(at full load)Environment of useProtection ratingOperating temperatureDimensions (H x D x W)MassInput AC power connectionAC Input voltage rangeAC Input current Power consumedRelative humidity

Authentication

CCS 50kW, CHAdeMO 50kW, AC 22kW type 2>94 %<55 dB

Indoor / outdoorIP54-30 °C to +50 °C1929 mm x 822 mm x 618 mmapprox. 650 kg 3 Phases + PE400 V

AC ± 10%3 x 150 AAC <130 W 5% to 95%(without condensation)RFID/NFC Reader/Writer

18

2b

Page 21: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

Product information

Network connection

Communication protocol

AccountingPower factor (50% load)AC output power

AC output voltageAC output currentDC output power

DC output voltage

DC output currentPayment systems

Ethernet, GSM, GPRS, UMTS (3G modem), LTE 4GOpen Charger Point Protocol (OCPP) 1.5(1.6 and 2.0 in preparation)Backend-side load management (OCPP 1.6)Accounting possible via backend system>97%22 kW/43 kW, IEC 62196 Mode 3, Type 2400 V

AC ± 10%3 x 32 AAC / 3 x 63 AAC

50 kW(CCS or CHAdeMO)920 VDC

(as of 850 V with derating)125 AISO 14443 A/B, Mifare,ISO 18092 (NFC),DESFire, FeliCA Mobile App

19

Page 22: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

20

General specifications:

CHARGERs fOR ELECTRIC HEAVy COmmERCIAL VEHICLEsI sicharge UC – Charging Center

Product information

Power, kWInput AC connectionCurrent at nominal voltage per phase, AInput voltage rangeMaximum output current,APeak power, kWOutput voltage rangeOperating temperature Power factor cos phiEnvironmentCharging standardsEMC standardsDimensions (W,D,H), mApprox. weight, kgNetwork connectionCommunication protocolProtection

** Complies with ISO15118-1 standard use-cases, further use-cases being implemented

50, 100, 150, 225, 300, 450, 6003P + PE76, 152, 228, 342, 456, 683, 911400 V AC +/- 10% (50 Hz or 6063, 125, 200, 300, 400, 600, 80063, 125, 200, 300, 400, 600, 80010-1000 V DC

-25 °C to +45 °C, extended upon request>0,98lndoor / OutdoorEN 61851-1/23/24, ISO 15118 (DIN 70121)**EN 55016-2-1 & -3; EN 61000-4-2 & -3 & -4 & -5 & -60,7x0,8x1,8; 0,91x1,0x2,0; 1,4x1,0x2,0; 2,4x1,0x2,0; 2,8x1,0x2,0700, 1000, 1400, 2000, 2600, 4000, 5200Ethernet / 3G and 4G / WLANOCPP 1.6 (J-SON)IP54- IK10

Page 23: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

21

General specifications:

Product information

Rated power standard, peak, liquid-cooled cable option, kWInput connectionRated input current & powerFrontend, Pantograph, HoodOutput current, AOutput (max. liquid cooled cable) current, (option), AOutput voltage rangeOperating range Pantograph, mm Material FrontendInv. pantograph / HoodHeight, installed, mm Cantiliver length, mmCommunication standardProtectionNumber of possible connectors (sequential charging)

150, 200 peak, 500 peak l-c option/600, 800 pea. /600, 800 pea.3P + PEFrom Charging CenterFully preinstalled, Electrically checked and equipped150 / 600 / 600500 / - / - 10-1000 V

DC Gal.steel powder coated/Gal.steel fib. glass panel/Gal.s painted RAL 9006 White alu.; 9017 Black matt / RAL 9006 White alu.With CCS cableUrban-industrial (extended) design/Industrial - T-shape design1765 / 5805-6576 / 5000 - / 3955-422-5200 / 3500-7000PLC / WiFi IEEE 802.11a / PLCIP54- IK10up to 5 / 1 / 2

CHARGERs fOR ELECTRIC HEAVy COmmERCIAL VEHICLEsI sicharge UC – Dispenser / Inverted Pantograph / mast mounted Hood

Page 24: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

22

Page 25: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

23

General specifications:

CAR ChARGERS - AC ChARGERS I EVlink Wallbox

Product information

Power per connector

Mounting

Charging connector

Environment of useProtection ratingOperating temperatureDimensions (H x W x D)MassPower supplyInput voltage rangeInput current, *Circuit breaker (overcurr.) *RCD (residual curr.)

*The charger operates autonomously. It has a dedicated protective device.

AC 3.7/7.4/22 kW; shuko/type 2Wall / FloorSocket outlet/domesticsocket option (TE)/attached cableIndoor / outdoorIP54, IK10-30 °C to +50 °C480 mm x 331,5 mm x 170 mm5,6 – 7,9 kg1 Ph. 3,7-7,4 kW; 3 Ph. 11 – 22 kW240/415 V

AC, 50/60 Hz16/32 A 20/40 A Curve C30 mA B Type

AuthenticationNetwork connectionCommunication protocol AnntenaEarthing systemEnergy metering

Key lock or RFID user authenticationWired Eth. 3 ports (LAN,WiFI,3G/4G, conn. to PC); Wi-Fi module or 3G/4G modem-accessoryMust be ordered separatelyTT, TN-S, TN-C-SIntegrated measuring of the apparent powerInterface with an external MID energy meter

3a

Page 26: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

24

General specifications:

CAR ChARGERS - DC CHARGERI EVlink DC Parking

Product information

ConnectorMountingCharging voltage/current

Environment of useProtection ratingOperating temperatureDimensions (H x W x D)MassPower supplyInput voltage rangeInput current, *Circuit breaker (overcurr.) *RCD (residual curr.)

Authentication

Network connectionCommunication protocolAnntenaEarthing systemEnergy metering

*The charger operates autonomously. It has a dedicated protective device.

7.4/22 kW per connector Wall / FloorWall mounted / Floor standingMode 3 with T2 or T2 with shutter socket outlet (T2/T1) regulationIndoor / outdoorIP54 (IEC 60529), IK10 (IEC 62262)-25 °C to +50 °C 413 (1146) mm x 413 mm x 220 (256) mm33-50 kg7,4 kW 220/240 V 1P+N or 22 kW 380/415 V 3P+N220-240/380-415 V

AC, 50/60 Hz10 A - 32 A 16/40 A Curve C30 mA B Type

RFID authentication; Mifare Ultralight, Mifare Classic 1K / 4K, I Code SLI, Tag-it HFITCP/IP; FTP, SMTP or HTTP data retrievalOpen Charger Point Protocol (OCPP) 1.5 or 1.6) Must be ordered separatelyTT, TN-S, TN-C-SIntegrated measuring of the apparent powerInterface with an external MID energy meter

3b

Page 27: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

25

General specifications:

CAR ChARGERS - DC CHARGERs EVlink DC fast Charge

Product information

ConnectorMountingCharging voltage/current

Environment of useProtection ratingOperating temperatureCharging powerMassPower supplyRelative humidityProtection

Communication

User interfaceCommunication protocolOperating altitudeCable lengthDimensions

DC CCS, CHAdeMO +AC typeWall / Floor150 to 530 V

DC / 1.5 to 65 A400 V ± 10% AC / 32 A maxIndoor / outdoorIP54, IK10-25 °C to +50 °C 24 kW DC; 22 kW AC

66 – 85 kg380 - 480 V, 3P+N+Earth, 50/60 Hz10% to 95%Against short circuit, overload; protected against overheating,temperature regulatedWireless 3G modem; LAN/TCP IP protocolRFID user authentication; 7-inch touch screenOpen Charger Point Protocol (OCPP) 1.5 or 1.6)2000 m max.3,25 mWall mounted:H 860 x L 507 x W 250 mmMono on pedestal: H 1533 x L 536 x W 336 mmMulti on pedestal: H 1835 x L 536 x W 336 mm

Page 28: ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor / Outdoor Standard: -10 C to +50 C Optional: -35 C to + 50 C Power cabinet : 1170 x 770

ROAMING NETWORKS I Oblakovska 51, 11000 Belgrade, Serbia

office +381 11 7854 74 I fax +381 11 7854 725 I www.roamingnetworks.com