el paso city council agenda item 8.6: title 18 amendment
DESCRIPTION
An Ordinance amending Title 18 (Building and Construction), Chapter 18.10 (Residential Code), of the El Paso City Code, to add an exception to the fire construction requirement for exterior walls, excepting zero lot line properties provided certain requirements are met, the penalty being as provided by Section 18.02.111 (Violations and Penalties) of the El Paso City Code . Applicant: City of El Paso, City Development Department. All DistrictsTRANSCRIPT
Recommendation/Public Input
• Building & Development Permitting Division recommendation: Approval
• CPC Vote: Approval Recommendation (N/A)
• Public Input: No communication received from the public in support or opposition to the proposed amendment.
City Development Department
July 15, 2014
City Development Department
Proposed Amendment to Title 18 (Building and Construction),
Chapter 18.10 (Residential Code) of the El Paso City Code.
City Development Department
Current provisions of 2009 IRC, Section 302.1Fire Resistant Construction
R302.1 Exterior walls. Construction, projections, openings and penetrations of exterior walls of dwellings and accessory buildings shall comply with Table R302.1.Exceptions:1. Walls, projections, openings or penetrations in walls perpendicular
to the line used to determine the fire separation distance.2. Walls of dwellings and accessory structures located on the same lot.3. Detached tool sheds and storage sheds, playhouses and similar
structures exempted from permits are not required to provide wall protection based on location on the lot. Projections beyond the exterior wall shall not extend over the lot line.
City Development Department
4. Detached garages accessory to a dwelling located within 2 feet (610 mm) of a lot line are permitted to have roof eave projections not exceeding 4 inches (102 mm).
5. Foundation vents installed in compliance with this code are permitted.
Current provisions of 2009 IRC, Section 302.1Fire Resistant Construction (Continued)
Table 302.1 Fire Resistant Construction• Prohibits glazing and openings when structure is less than 3 feet
from property line.• 25% maximum of wall area allowed to have openings between 3 to
5 feet. • Unlimited openings allowed when wall is ≥ 5feet
City Development Department
City Development DepartmentExample of current provision
City Development Department
Will allow non-operable glazing on Zero lot line where all the following apply:• A minimum of 10 feet is provided between structures.• Glazing is at a height of 14 feet above grade level• Glazing is not more that 10% of wall area• Eaves do not extend more than 12 inches from wall and are fire
rated.And allows unlimited operable openings when:• All structures are provided with a sprinkler system.
Proposed Revisions
Property Line10’ Between
structures
• Glazing is at a height of 14 feet above grade level
• Glazing is not more that 10% of wall area
• Openings prohibited
City Development Department
14’ Minimum Height
• Glazing is at a height of 14 feet above grade level
• Glazing is not more that 10% of wall area
• Openings prohibited
City Development Department
City Development Department
Questions