EGi Secura "primma" is an alarm and intercommunication system to be used in public
installations and specially in hospitals and residential homes for the elderly.
As it is easy to operate and to install, Secura Primma is the most competitive and suitable
solution for hospitals and residential homes for the elderly which have up to 1020 rooms.
These rooms can be controlled from one or more places which, in turn, can be re-addressed
to a different control point (e.g. to the night duty post).
Assistance communication
in hospitals and residential
homes for the elderly
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 4/12
4
EGi Secura "primma" is an alarm and intercommunication
system wich allows:
Assistance communication
in hospitals and residences
for the elderly,up to 1020 rooms.
Alarm management either manual or
automatically generated from rooms (bedrooms) or other places.
Call identification (room origin,
type of alarm, ...) and
assistance information.
In-the-room lighting signal indicating
alarm activation and its type:presence, normal, urgency or emergency.
Bi-directional communicationbetween resident and control point.
Computer connection for querying,
on screen or printed report,of historical alarm events ordered by type,
date or resident.
Easy bus type installation.
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 5/12
5
Assistance communication
in hospitals and residentialhomes for the elderly
Medical and health centres
Hospitals
Emergency centres
Specialized clinics
Spa
Residential homes for the elderly
Residences
Apartments
Day care centres
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 6/12
6
5503
125
110
70mm5503
Under order
Remote room terminal
Placed in the floor bus, this device connects 2 single rooms or a double room
(with 2 beds) to its nurse calling station. It is connected to the system by a 6-wire bus cable (power, data and audio)
EGi ref. 5504.
To be fastened to DIN rail (7u. width) and placed in a surface mounting box
or flush mounting box.
It is equiped with plug-in connectors to make the installation easier.
It must be placed as close as possible to the room(s) to be controlled. It can
be concealed in a false ceiling as long as a solid structure it is used (never
loose-fitting or leant on the false ceiling).
Available per room:
Digital inputs: assistant care presence, normal call and urgency call
(through normally closed push-button activation).
Digital outputs: presence and call signals.
Configurable auxiliary port.
Preamplified microphone and loudspeaker to allow bidirectionalconversation with the floor control unit.
Up to 510 remote room terminals can be installed (which means up to 1020
single rooms).
The terminal can be configurable as:
MODE 1: installation for 2 single rooms with individual recognition of the
patient generating the call; auxiliary port available to be used as input/output,
or installation in a double room without individual recognition of the patient
generating the call; auxiliary port not available as it is being used by the
second bed of each room.
MODE 2: installation in a double room, with individual recognition of the
patient generating the call; auxiliary port available to be used as input/output.
Configurable auxiliary port can be set as input/output (the configuration for
both rooms is shared). When set as input, it could be used to generate either
normal or urgency calls as soon as the room will be provided with additional
warning elements (presence sensor, window opening sensor,...). When set as
output, it can be used to activate any device through a free-voltage contact.
Equipped with fast connectors to make the installation easier
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 7/12
7
5303
5803
71
71
49mm
248
200
180mm
5803
5303
Under order
Floor interface
Floor interface is the device that links the floor bus into the inter-floor bus. In
the same way, it links a group of remote room terminals into its corresponding
nurse calling station. Even more, any call from a room can be diverted to the
main nurse calling station whenever its nurse calling station is out of order.
The following connections are allowed:
to the nurse calling station through a flexible cable (included) with RJ12
connectors at both ends
to floor bus and inter-floor bus through terminal blocks connections (*),
to the computer through the interface 5805 with a flexible cable with RJ12
connectors at both ends.
VERY IMPORTANT: connection between the floor interface and the inter-floor
bus will always be made through the bus signal generator 5804 (a 100x100
mm junction box is recommended). DO NOT CONNECT THE FLOOR
INTERFACE DIRECTLY TO THE INTER-FLOOR BUS
Nurse calling station
It allows to receive calls from the assigned rooms as well as establish an audio
communication with them.
It has been thought as an independent unit for each floor of a building so that
it can answer the calls received from that floor.
All the calls from any floor can be diverted from its assigned calling station
to the designated main nurse calling station, so that any call from any room
can be answered in only one place. IT IS RECOMMENDED to have a place
where a main nurse calling station can supervise the good working order of
the system.
The main nurse calling station displays all the events permanently but it will
not take part on a room alarm unless the calls from that floor are diverted.
Any nurse calling station can be configurated as main, but there can only be
one.
The nurse calling station consists of 2 devices:
a customized telephone terminal
a console with display screen, desk microphone and loudspeaker.
Apart from answering the calls from the residents, it can establish a conversation
with the rooms by simply dialing the room number on the telephone keyboard.
There are two ways of answering a call:
by using the console microphone and loudspeaker (halfduplex conversation
mode), by pressing and releasing the speaking push-button
by picking-up the handset once the call is selected on the console (private
and full-duplex conversation mode).
The unit has 2 connectors:
RJ12 to be connected to the floor interface
RJ45 to connect the customized telephone terminal (included).
There are 2 potentiometers available to adjust the loudspeaker volume level
and the micro-loudspeaker volume level of the handset.
Maximum 32 nurse calling stations per installation.
A nurse calling station contains: A customized telephone
terminal. A nurse console with
display, gooseneckmicrophone andloudspeaker.
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 8/12
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 9/12
9
5201
5201
5701
5103
5202
5204
5104
G26U/16
5701
5103
5202
5104
G26U/16
5204
520607.12LED corridor lights
Allow the visual information about the type of call generated in one room.
Can be installed in standard 60 mm flush-mount box.
LED technology to reduce consumption and maintenance costs.
Green and red colour.
White coloured when in "off" mode and red or green coloured when activated.
This makes it easy to distinguish when the system is activated, while allowing
easy integration into the hospital decor.
Bathroom pull-cord wall unit
To be installed in a 60 mm standard box, it can combine with other series of
electrical switchgear.
It works together with the bathroom pull-cord EGi 5701.
Bathroom pull-cord
Ergonomic design.
It incorporates a 2m cord with anti-strangling system.
Fluorescent ring to facilitate visibility in the dark.
To connect to EGi 5201.
Acoustic alarm when pulling the cord.
Bedside push-button wall unit
To be installed in a 60 mm standard box, it can combine with other series ofelectrical switchgear.
It works together with the bedside push-button EGi 5202.
Jack connector reduces accidental pull-off. In this case, an alarm is generated.
Bedside push-button
Ergonomic design.
Fluorescent ring to facilitate visibility in the dark.
To connect to EGi 5103.
Acoustic alarm when pushing the button.
It incorporates anti-strangling system.
Nurse presence push-button
To be installed in a 60 mm standard box, it can combine with other series of
electrical switchgear.
When pushed, it allows to notify nurse presence in the patients room.
Microphone + preamplifier
To be installed in a 60 mm standard box, it can combine with other series of
electrical switchgear.
It works together with the loudspeakerG26U/16 or other EGi 16 loudspeakers.
It allows hands-free conversation between the user and care assistants.
Under order
Loudspeaker 2 W 16 W
2" wall loudspeaker for 60 mm mounting box. Wide band. 16 impedance.
5211
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 10/12
1 0
The installation is based on the use of a field bus of 6-wire cable (powersupply, digital data and audio).
Bus topology is described on the image below. Two bus levels are
considered: floor bus and inter-floor bus. Floor bus gathers remote roomterminals of this floor and its nurse calling station; inter-floor bus gathers
System architecture
floor buses through bus signal generators. One or more 15 Vdc powersupply are needed depending on the number of connected devices.
Each remote room terminal can control two single rooms or a double
room. It incorporates input and output ports for controlling alarm activation.
1st Floor
Hall/Reception
2nd Floor
"N" Floor
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 11/12
8/8/2019 EGi - Secura Primma Brochure (English) - 004806
http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 12/12
D I S T R I B U T O R
Avenida Almozara, 7950003 ZARAGOZASPAIN
Tel. +34 976 40 53 56Fax +34 976 40 53 54
e-mail: [email protected]
D E
S I N G A
N D P
R E - P R I N T I N G :
+ 3 4 9 7 6 5 9 0 7 4 9
C ó d . 0 0 4 8 0 6
D . L . : Z - 0 0 0 0 - 0 0