11.12 Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 Individually adjustable forced air heaters for each room — the best solution for low-energy and passive houses ECO SERIES www.climecon.fi 1

Upload: others

Post on 20-Aug-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

11.1

2

Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

Individually adjustable forced air heaters for each room — the best solution for low-energy and passive houses

ECO SERIES

www.climecon.fi 1

Page 2: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

2www.climecon.fi Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

The silent ECO series forced-air heaters work by heating preheated air based on

the requirements of each room individually. Heating is controlled by accurate PI

control ensuring high thermal comfort. The intelligent system reacts quickly to

temperature changes and keeps the room temperature precisely at the desired

level.

One of the features of the ECO series is accurate heating adjustment for each

room separately. Because heating takes place in the room as needed, ECO

products involve minimal heat losses in the air ducts. The ECO series is the

perfect choice for optimal energy efficiency, simplicity and clarity in heating

adjustment and high thermal comfort in every room.

ECO

Page 3: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

3www.climecon.fi Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

0 2 4 6 8 10 12 14 16 18 20 22 24Time (h)

Heat load35

30

25

20

15

10

Supply air temperatureRoom air temperature

Heating capacity decreases

Heating o�

Heating resumes

1

2

3

1

2

3

A passive house requires the right type of heatingBuilding technology design for passive houses starts from minimising the need for heating and cooling. At best, the energy requirement for heating a passive house is no more than 20–30 kWh per gross square metre and 10–20 W per square metre for the rooms. These figures correspond with the definition of a passive house by the Technical Research Centre of Finland. The low overall heating power consumption requires that the heating system also works at low power and, most importantly, that it reacts quickly to changes. Room temperatures must be individually controllable to achieve high energy efficiency and thermal comfort.

The graph shows the drop in supply air temperature with an additional heat load in the room, such as heat from the sun, fireplace or people. Supply air temperature drops below room temperature to compen-sate for the additional heat load and main-tain a constant room temperature.

Your best choice: individual forced-air heating for each roomThe best heating method for a passive house is forced-air heating.

When heating rooms individually, air flows do not need to be changed as heating needs vary because the supply air temperature will be automatically regulated according to the heating needs of each room.

0.5

0.42

0.33

0.25

0.17

0.08

0.00

Flow velocity

[m/s]

23.00

22.80

22.60

22.40

22.20

22.00

21.80

21.60

21.40

21.20

21.00

Temperature

Flow velocity Temperature

ECO forced-air heaters achieve an even, draught-free air distribution in the entire room, thanks to their high mixing ratio.

The temperature distribution within the entire room space is extremely even in passive houses and its rooms heated with ECO forced-air heaters. The cooler area at the front of the graph was caused by cooler air through the window.

With the structures and materials specially desig-ned for passive houses and built carefully, even air supplied from above close to the ceiling will be distributed evenly throughout the room.

Page 4: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

4www.climecon.fi Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

Silent, energy-efficient heatThe silently operating ECO forced-air heaters work by heating air that is approximately 15–17°C based on the requirements of each room individually.

Precise adjustment for best comfortHeating is controlled by accurate PI control ensuring high thermal comfort. The higher the deviation from the preset value, the higher the heating power. When the room temperature is close to the preset value, the unit works at lower power.

The control unit that houses the room temperature sensor has no heat-emitting components. This achieves a very accurate measurement of room temperature.

The intelligent system reacts quickly to temperature changes and keeps the room temperature precisely at the desired level.

Comfortable heat with low energy consumptionThe ECO system switches on for extremely short, precisely defined cycles, keeping the surface temperature of the heating element as low as possible. The low surface temperature, due to the large surface area of the element, does not burn dust.

Preheated supply air ~ 15–17°C

Supply air heated to room requirements

Heating control unit

The heating energy consumption of ECO forced-air heater in two similar 186-m2 passive houses in the Helsinki, Finland, region in 2010 and 2011(*

House B: Heated through a combination of an air-source heat pump and ECO forced-air heaters. Winter 2011 included a period when people were not present in the house and the floor heating, for example, was minimised. This is reflected as a peak in the energy consumption of the ECO heaters.

House A: ECO forced-air heaters are the only prin-cipal heat sources besides a fireplace. Note! In 2011, the targeted air flow and heating adjustments were achieved and heating energy consumption lowered.

*)Consumption figures valid only for these example houses.

700

600

500

400

300

200

100

0

kWh

20102011

January

February

March April

May

JuneJuly

August

Septem

ber

October

Novem

ber

Decem

ber

400

350

300

250

200

150

100

50

0

20102011

January

February

March April

May

JuneJuly

August

Septem

ber

October

Novem

ber

Decem

ber

kWh

Page 5: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

5www.climecon.fi Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

Air flow, dm3/s

Device fully open, top edge 10 mm from ceiling

Device fully open, top edge 100 mm from ceiling

Device fully open

5 8 10 15 20 30

Air flow, dm3/s5 8 10 15 20 30

Air flow, dm3/s5 8 10 15 20 30

2520

30

25

20

30

LpA10, dB(A)

LpA10, dB(A)

LpA10, dB(A)

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

Air flow, dm3/s

Thro

w le

ngth

L0.

2, mTh

row

leng

th L

0.2, m

6 8 10 20 30

Air flow, dm3/s6 8 10 20 30 40 50 80 100

Air flow, dm3/s5 10 15 30 40 50 80

4,0

2,0

1,5

1,0

654

3

2

1

Thro

w le

ngth

L0.

2, m

654

3

2

1

Adjustment position, horizontal rows open

4 6 max ECO1

ECO2

ECO3

3

20 40 60

69

max

max

Adjustment position, horizontal rows open

Adjustment position, vertical rows open

30

25

20

Air flow, dm3/s

Device fully open, top edge 10 mm from ceiling

Device fully open, top edge 100 mm from ceiling

Device fully open

5 8 10 15 20 30

Air flow, dm3/s5 8 10 15 20 30

Air flow, dm3/s5 8 10 15 20 30

2520

30

25

20

30

LpA10, dB(A)

LpA10, dB(A)

LpA10, dB(A)

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

Air flow, dm3/s

Thro

w le

ngth

L0.

2, mTh

row

leng

th L

0.2, m

6 8 10 20 30

Air flow, dm3/s6 8 10 20 30 40 50 80 100

Air flow, dm3/s5 10 15 30 40 50 80

4,0

2,0

1,5

1,0

654

3

2

1

Thro

w le

ngth

L0.

2, m

654

3

2

1

Adjustment position, horizontal rows open

4 6 max ECO1

ECO2

ECO3

3

20 40 60

69

max

max

Adjustment position, horizontal rows open

Adjustment position, vertical rows open

30

25

20

Air flow, dm3/s

Device fully open, top edge 10 mm from ceiling

Device fully open, top edge 100 mm from ceiling

Device fully open

5 8 10 15 20 30

Air flow, dm3/s5 8 10 15 20 30

Air flow, dm3/s5 8 10 15 20 30

2520

30

25

20

30

LpA10, dB(A)

LpA10, dB(A)

LpA10, dB(A)

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a

Air flow, dm3/s

Thro

w le

ngth

L0.

2, mTh

row

leng

th L

0.2, m

6 8 10 20 30

Air flow, dm3/s6 8 10 20 30 40 50 80 100

Air flow, dm3/s5 10 15 30 40 50 80

4,0

2,0

1,5

1,0

654

3

2

1

Thro

w le

ngth

L0.

2, m

654

3

2

1

Adjustment position, horizontal rows open

4 6 max ECO1

ECO2

ECO3

3

20 40 60

69

max

max

Adjustment position, horizontal rows open

Adjustment position, vertical rows open

30

25

20

ECO 1, wall mounting

ECO 2, wall mounting

ECO 3, ceiling mounting

ECO 4, wall mounting

ECO control unit

Device fully open, top edge 10 mm from ceiling

Air flow, dm3/s5 8 10 15 20 30

25

20

30

100

80

50

40

30

20

10Tota

l pre

ssur

e, P

a Air flow, dm3/s6 8 10 20 30

Thro

w le

ngth

L0.

2, m

4 6 10 14max22

4,0

2,0

1,5

1,0

LpA10, dB(A)

ECO4Adjustment position, horizontal rows open

Sound power level

Size f, Hz 63 125 250 500 1k 2k 4k 8kECO1 K, dB 0 -4 -1 2 0 -4 -17 -11ECO2 K, dB -10 -7 -3 1 1 -6 -15 -11ECO3 K, dB -1 -4 -1 1 0 -4 -13 -16ECO4 K, dB -8 -6 -5 -1 0 -5 -10 -11

Size f, Hz 63 125 250 500 1k 2k 4k 8kECO1 ∆L, dB 21 14 9 4 2 4 5 6ECO2 ∆L, dB 21 14 9 3 2 4 4 5ECO3 ∆L, dB 20 14 9 5 2 4 6 7ECO4 ∆L, dB 20 14 8 2 1 4 4 5

Sound attenuation

Lwokt= LpA10+K

Sound level will increase if cover distance is below 3xØd:- after bend +4 dB (A)- after T joint +8 dB (A)

Sound level increase

Change in supply air temperature does not affect throw length. Width of throw pattern increases. See page 6.

Change in supply air temperature does not affect throw length. Width of throw pattern increases. See page 6.

Change in supply air temperature does not affect throw length.

Change in supply air temperature does not affect throw length.

Page 6: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

6

L0,2

L0,2

L0,2ECO1 Lb = 0,5 x L0,2

ECO2 Lb = 0,4 x L0,2ECO4 Lb = 0,4 x L0,2

Heating on: ECO1 Lb = 0,7 x L0,2ECO2 Lb = 0,6 x L0,2ECO4 Lb = 0,6 x L0,2

Lb

H

H1

H2

d

min.

ECO-controlunit

ECO-controlunit

CD

B

A

250

200

49,3

151,

50

12

48

183,50 nim. 125

L0,2

L0,2

L0,2ECO1 Lb = 0,5 x L0,2

ECO2 Lb = 0,4 x L0,2ECO4 Lb = 0,4 x L0,2

Heating on: ECO1 Lb = 0,7 x L0,2ECO2 Lb = 0,6 x L0,2ECO4 Lb = 0,6 x L0,2

Lb

H

H1

H2

d

min.

ECO-controlunit

ECO-controlunit

CD

B

A

250

200

49,3

151,

50

12

48

183,50 nim. 125

L0,2

L0,2

L0,2ECO1 Lb = 0,5 x L0,2

ECO2 Lb = 0,4 x L0,2ECO4 Lb = 0,4 x L0,2

Lämmitys päällä: ECO1 Lb = 0,7 x L0,2ECO2 Lb = 0,6 x L0,2ECO4 Lb = 0,6 x L0,2

Lb

H

H1

H2

d

min.

ECO-säädin

ECO-säädinCD

B

A

250

200

49,3

151,

50

12

48

183,50 nim. 125

Examples of the connection cables

www.climecon.fi Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

L0,2

L0,2

L0,2ECO1 Lb = 0,5 x L0,2

ECO2 Lb = 0,4 x L0,2ECO4 Lb = 0,4 x L0,2

Heating on: ECO1 Lb = 0,7 x L0,2ECO2 Lb = 0,6 x L0,2ECO4 Lb = 0,6 x L0,2

Lb

H

H1

H2

d

min.

ECO-controlunit

ECO-controlunit

CD

B

A

250

200

49,3

151,

50

12

48

183,50 nim. 125

L0,2

L0,2

L0,2ECO1 Lb = 0,5 x L0,2

ECO2 Lb = 0,4 x L0,2ECO4 Lb = 0,4 x L0,2

Heating on: ECO1 Lb = 0,7 x L0,2ECO2 Lb = 0,6 x L0,2ECO4 Lb = 0,6 x L0,2

Lb

H

H1

H2

d

min.

ECO-controlunit

ECO-controlunit

CD

B

A

250

200

49,3

151,

50

12

48

183,50 nim. 125

Throw patterns

ECO 1, ECO 2, ECO 4 ECO 3

Dimensions Connection

Technical specifications of forced-air heater

Voltage 230V / 50 Hz

Power max 300–400 W (8–15 dm3/s)

Circuit breaker 10 A for one forced-air heater

16 A for two forced-air heaters

Duct size Ø125 mm

Technical specifications of control unit

Voltage 24 Vac (20–26 Vac)

Accuracy ± 0,5°C

Connectors 1.5 mm

Enclosure class IP20, surface mounted

Factory setting Adjustment range centre 21°C,

adjustment range 18–24°C

Technical specificationsECO 4

ECO 1, 2, 3

Ø d ØH A B C D min

ECO1 125 135 200 158 65 40 10 ECO2 125 135 280 177 73 40 70 ECO3 125 135 Ø255 - 70 45 500 ECO4 125 (H1)194x(H2)162 250 200 12 96,5 10

Code Description

ECOxT Forced-air heater + control unit ECOx Forced-air heater ECOT Control unit

ECO product alternatives

Page 7: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

7www.climecon.fi Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

Excellent heating with small air flowsIn a passive house, the air permeability of the building’s envelope must be below 0.6 1/h. This avoids draught problems and heavily layered temperatures, both typical in old houses.

Forced-air heating in a passive house will work per-fectly. With ECO forced-air heaters, you can achieve a good indoor climate with an air volume of 6 - 8 dm3/s/person with a total outdoor air flow of at least 0.35 dm3/s/m2. On hot summer days, an accelerated out-door air flow is used for cooling if necessary.

A suitable heating method for wet rooms with tiled surfaces in passive houses is low-power floor heating, which will also accelerate the drying of the floor sur-faces. Floor temperature should exceed room tempe-rature by only 2–4°C.

Only the right product guarantees functionalityThe devices for forced-air heating must be specially designed for their purpose. The pressure difference must be sufficient, not less than 20 Pa, to achieve the best mixing ratio and thermal comfort. As the heated supply air is blown from the top of the walls or from the ceiling toward windows, there will be no temperature layers or a feeling of draught. Window constructions should be designed specifically for pas-sive houses.

Forced-air heating in individual rooms brings many benefits+ Temperatures adjustable individually in each room

+ Minimised heat losses in air ducts

+ Reliability of a decentralised system

+ Quick response to heat load changes in rooms

These factors have a direct effect on the energy con-sumption and temperature control of your house. As a result, you will get increased thermal comfort and a good, safe indoor climate.

Temperature setback switch for even better energy efficiencyYou can optimise your energy consumption even more by using the stepless temperature drop function available for the ECO heating system. When you leave the house, you can lower the room temperature by 3–10°C from the preset value.

The function is activated through potential free con-tact information from your home automation system, or simply by a manual switch installed next to the front door.

Easy maintenance—only cleaning requiredYour heating system should be easy to maintain and clean. The ECO series products can be easily opened for cleaning both the device itself and the air ducts. That is all the maintenance the system will require.

One to three devices per roomFor smaller rooms, such as bedrooms, one ECO forced-air heater is usually enough. Two or three heaters are usually installed in larger rooms, such as living rooms. Even if the room has two or three devices, control is still performed using only one ECO series control unit.

In a normal heating environment, the power of an ECO forced-air heater is 30–400 W, depending on your hea-ting requirements. The starting current spike of the self-limiting ceramic heater core element should be taken into account when dimensioning the system.

The excellent air and sound performance of the ECO series, as well as its advanced PI control method and high-quality components provide an energy-efficient, silent, comfortable and safe indoor climate in a passive house.

Climecon’s ECO products, made in Finland, are tested by the Technical Research Centre of Finland*). Electrical safety is guaranteed through approval by SGS Fimko and the FI sign.

Page 8: ECO SERIES - mapuk.com  Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609 2 The silent ECO series forced-air …

www.climecon.fi

www.climecon.fi 8Lämmittäjänkatu 4 A, FI-00880 HELSINKI, Finland · Telephone +358 20 198 6600, Fax +358 020 198 6609

Installation example of ECO forced-air heaters

Installation example for a passive house Two to three ECO forced-air heaters are installed in large spaces, all controlled by one ECOT control unit. One ECO forced-air heater is suffi-cient for smaller rooms.