Eclipse Powerhouse Gripper Arm Replacement Instructions Part Number ECLPHARMKIT Please follow these instructions to install replacement gripper arms into your Eclipse Powerhouse. Tools Needed: Torx® T15 screwdriver (recommended length: 80mm) 1 Remove four (4) screws from back of Eclipse Powerhouse. 2 Carefully lift back plate (be sure not to rip any wires out). Unplug one connection from board. 3 Remove six (6) screws from plastic shims and place screws and shims to the side. 4 Rotate shims (next to shaft) to the side to remove shaft. 5 Slide metal shaft up and out of plastic cradle. 6 Pull metal shaft up and out of gripper arms. Gripper arms should slide out. Dispose of gripper arms. www.bullard.com

Upload: others

Post on 27-Jun-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Eclipse Powerhouse Gripper Arm Replacement Instructions...Eclipse Powerhouse Gripper Arm Replacement Instructions Part Number ECLPHARMKIT Please follow these instructions to install

Eclipse Powerhouse Gripper Arm Replacement Instructions

Part Number ECLPHARMKIT

Please follow these instructions to install replacement gripper arms into your Eclipse Powerhouse.

Tools Needed: Torx® T15 screwdriver (recommended length: 80mm)

1

Remove four (4) screws from back of Eclipse Powerhouse.

2

Carefully lift back plate (be sure not to rip any wires out). Unplug one connection from board.

3

Remove six (6) screws from plastic shims and place screws and shims to the side.

4

Rotate shims (next to shaft) to the side to remove shaft.

5

Slide metal shaft up and out of plastic cradle.

6

Pull metal shaft up and out of gripper arms. Gripper arms should slide out. Dispose of gripper arms.

w w w . b u l l a r d . c o m

Page 2: Eclipse Powerhouse Gripper Arm Replacement Instructions...Eclipse Powerhouse Gripper Arm Replacement Instructions Part Number ECLPHARMKIT Please follow these instructions to install

©2017 Bullard. All rights reserved.

60510011636A EN (0317)

ISO 9001 certified

w w w . b u l l a r d . c o m

Americas:Bullard1898 Safety Way Cynthiana, KY 41031-9303 • USAToll-free within USA: 877-BULLARD (285-5273)Tel: +1-859-234-6616 Fax: +1-859-234-8987

Europe:Bullard GmbHLilienthalstrasse 1253424 Remagen • GermanyTel: +49-2642 999980 Fax: +49-2642 9999829

Asia-Pacific:Bullard Asia Pacific Pte. Ltd.LHK Building701, Sims Drive, #04-03 Singapore 387383Tel: +65-6745-0556 Fax: +65-6745-5176

9

Thread the screws through the plastic shims and tighten screws to secure gripper arms and shaft.

10

When closing the powerhouse, thread wires through hole in plate to keep them accessible.

7

Line gripper arms as shown with notch resting in opening of second gripper arm (as shown). Slide gripper arms down into housing.

8

Thread shaft through hole of gripper arm, placing top of shaft back in plastic cradle. Pin in center of shaft will slide into notches, and shaft will align correctly.

11

Plug connector back into board.

12