e7935-5-10-12_of5mini_lq.pdf

Upload: chanayire

Post on 03-Apr-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/27/2019 E7935-5-10-12_OF5mini_LQ.pdf

    1/4

    E7.9

    35.5

    /10.1

    2

    141

    Filtromat

    OF 5 Mini

    DescrptonThe stationary uid service unitOF5 Mini is designed to ll/lter

    hydraulic and lubrication tanks and tolter ofine. The change-over valveis provided to bypass the lter whenemptying tanks.

    AppcatonszHydraulic and lubrication oilsystems in a variety of industries

    zMobile hydraulics

    AdvantageszConvenient ofine ltration

    zVery compact designzGreater system availability

    zReduction of Life Cycle Cost LCC

    Technical specifcations

    Max. ow rate 15 l/min

    Operating pressure 4.5 bar maxPermitted suction pressure at suction port -0.4 bar ... +0.6 bar

    Pump type Gerotor or vane pump

    Viscosity range 15 ... 350 mm/s

    Permitted operating uid Mineral oil (others on request)

    Fluid temperature range -10 ... 80 C

    Ambient temperature range -20 ... 40 C

    Protection class IP 55

    Weight 20 kg

    Eectrc motor output

    Gerotor pump 0,37 kW @ 50 HzVane pump 0,2 kW @ 50 Hz

  • 7/27/2019 E7935-5-10-12_OF5mini_LQ.pdf

    2/4

    Mode code

    OF5 M 20 V 1 M 2 N5DM002 E - /Basc typeOF5

    VersonM = Stationary with change-over valve

    Type code20 = StandardSpecial models on request

    SeasV = FPM (Viton)

    Motor-pump untCode Approx. ow rate at 1450 rpm Electric motor input at 50 Hz1 15 l/min (at 40 mm/s) 0.37 kWother on request

    VotageL = 115 V - 1 Ph T = 12V DCM = 230 V - 1 Ph* U = 24V DCN = 400 V - 3 Ph*X = other voltages on requestM60 = operation at 60Hz* Standard in Europe according to CENELEC HD472 S1 at 50 Hz

    Fter sze2 = 1 Element N5

    Fter eementN 5 DM 002 = DIMICRON 2 m absoluteN 5 DM 005 = DIMICRON 5 m absoluteN 5 DM 010 = DIMICRON 10 m absoluteN 5 DM 020 = DIMICRON 20 m absoluteN 5 AM 001 = AQUAMICRON 1 m absoluteN 5 AM 002 = AQUAMICRON 2 m absoluteN 5 AM 020 = AQUAMICRON 20 m absolute

    Coggng ndcatorE = Standard, pressure gauge

    Suppementary detas

    Accessores (optona)- OF5M anti-vibration mounting kit

    for universal mountingPart. No.: 3124658

    Repacement eements

    Ftraton ratng Eement type Part No

    2 m (Dimicron) N5DM002 349494

    5 m (Dimicron) N5DM005 3068101

    10 m (Dimicron) N5DM010 3102924

    20 m (Dimicron) N5DM020 3023508

    1 m (Aquamicron) N5AM001 3114428

    2 m (Aquamicron) N5AM002 349677

    20 m (Aquamicron) N5AM020 3040345

  • 7/27/2019 E7935-5-10-12_OF5mini_LQ.pdf

    3/4

    E7.9

    35.5

    /10.1

    2

    143

    Dmensons

    Hydrauc crcut dagram

    I Emptying tank, lter is bypassed

    A B

    II Filtering ofine A T III Filling via lter B T

    A Suction port G1

    B Transfer port G3/4

    T Tank port G3/4

  • 7/27/2019 E7935-5-10-12_OF5mini_LQ.pdf

    4/4

    Note

    The information in this brochure relates tothe operating conditions and applicationsdescribed.

    For applications and operating conditionsnot described, please contact the relevanttechnical department.

    Subject to technical modications.

    HYDAC FilTER SYSTEMS GMBH

    IndustriegebietD-66280 Suzbach / SaarTel.:+49 (0) 6897/509-01Fax:+49 (0) 6897/509-846Internet: www.hydac.comE-Mail: [email protected]