e02-017: lifetime of heavy hypernuclei introduction and status xiyu qiu lanzhou university hall c...
TRANSCRIPT
![Page 1: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/1.jpg)
E02-017: Lifetime of Heavy Hypernuclei
Introduction and Status
Xiyu QiuLanzhou University
Hall C meetingJan 13, 2012
![Page 2: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/2.jpg)
Outline
• Physics motivation• Experimental setup• Data analysis status Position & Timing Reconstruction• Future
![Page 3: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/3.jpg)
Physics motivation• Study hadronic weak interactions by the
unique (non-mesonic) decay in the nuclear medium after formation of hypernuclei– Non-mesonic decay (NNN) is believed to be dominant for
heavy hypernuclei– Large release energy from decay causes binary fission
which is utilized by this experiment
• Provide crucial information on the short range nature of the hyperon-baryon interaction– A dependence to heavy mass region is needed
![Page 4: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/4.jpg)
Physics motivation – cont.
• Limited data in light to medium mass region indicates a constant lifetime about 200-220ps.• COSY-13 result was from indirect measurements and is the only one in heavy mass region. It contradicts to our general believe and could not be explained by the current theories
Our goals: 1) An independent but direct lifetime measurement in heavy mass region (Challenge or confirm the COSY result) 2) Possible A dependence from multiple target materials: Fe, Cu, Ag, Au, and Bi
![Page 5: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/5.jpg)
Experimental Setup The main detector of this exp.
![Page 6: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/6.jpg)
FFD structure
![Page 7: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/7.jpg)
Analysis: Source (Cf-252) Data Calibration
Source fragment trajectory Single plane residual <0.9mm
Position determination: Xi =(Xil-Xir)/2.0, i = 1, 2, 3, 4.
![Page 8: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/8.jpg)
Analysis: Data with Beam
target fragment trajectory Events distribution on the target
Position determination: Xi =(Xil-Xir)/2.0, i = 1, 2, 3, 4.
X0
Z0
![Page 9: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/9.jpg)
Analysis: Beam Data Timing
Definitions: Measured time of flights: T_12 = T1-T2, T_43 = T4-T3; Calculated time of flights: using the fixed Z distances between planes and measured TOFs; T_10, T_20, T_30, T_40 (“0” refers to fission point on target)
_ 30_ 30 * _ 34
_ 34
LT T
L
For example:
(without needed corrections)
![Page 10: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/10.jpg)
Analysis: Beam Data Timing(I)Fission time zero: T0_f Algorithm:
![Page 11: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/11.jpg)
Analysis: Beam Data Timing(II)
Fission time zero 0 _T f
1 2 3(0 _ 3 _ 30 _ 4 3) ( 1 2) ( 4 1)10 f TT f T T T T f T T f T T
1( 4 3)f T T ------Energy loss correction
2 ( 1 2)f T T ------additional energy loss correction using the correlation between fragment I and II
3( 4 1)f T T ------ Trigger time walk correction
![Page 12: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/12.jpg)
Analysis: Beam Data Timing(III)Production time zero:T0_pAlgorithm:
![Page 13: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/13.jpg)
Analysis: Beam Data Timing(IV)
3232
_100 _ ( 1.0) 18 ( _10)
18
RF TT p Int RF T
0 _T p
Which is the ideal formula, must includes Energy loss correction in the calculation.
Production time zero:
![Page 14: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/14.jpg)
Analysis: Time SpectrumBeam data: T = T0_p - T0_f
Simulation:
Prompt:Delay = 1:1
Expected Prompt/Delay: ~ 400:1
![Page 15: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/15.jpg)
What’s learned from simulation
New Extracting Method:1) Fit the main Prompt events;2) Substract the Prompt events from Time Spectrum;3) Fit the left-over spectrum.
The ratio between the prompt and delay in the mixture has important impact on extracting the lifetime of hypernuclei.
![Page 16: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/16.jpg)
SummaryAfter long time struggling, the Fission timezero, Production time zero and the TimeSpectrum have been extracted.
To Do Work on the investigation for other new Lifetime Extracting Method, then evaluate the system error.
![Page 17: E02-017: Lifetime of Heavy Hypernuclei Introduction and Status Xiyu Qiu Lanzhou University Hall C meeting Jan 13, 2012](https://reader035.vdocuments.mx/reader035/viewer/2022062305/5697bf8a1a28abf838c8a8dd/html5/thumbnails/17.jpg)
Thanks for your attention!