Ultrasound guided distal transradial („snuff box” area) angiography and angioplasty using

5F guiding or 6F sheathless guiding system

Ruzsa Z., Tóth J., Molnár L., Édes I. F., Bárczi Gy., Merkely B.

AimRadial 2017

Page 2: E-poster07 Ruzsa aimradial20170921 Snuff box access

Disclosures

• I have no conflict of interest to declare

Page 3: E-poster07 Ruzsa aimradial20170921 Snuff box access

Background• First introduced for haemodialysis access in 1996

• Snuff box access published in 1998

• My first case in 2010 for Cimino fistula intervention and my fisrt coronary case in 2014

• Avtandil Babunashvili started the TENDERA study

• Snuff box access published by F Kiemeney in 2017

Page 4: E-poster07 Ruzsa aimradial20170921 Snuff box access

Background- Anatomy

Page 5: E-poster07 Ruzsa aimradial20170921 Snuff box access

Methods

• Prospective study performing all transradial diagnostic catheterrisationsand interventions from the anatomical „snuff box” area with a 5F guidingor 6F sheathless guiding

• (150 patients and 76 fully analysed)

• Primary end-point• Technical success of the intervention

• Procedural complications

• Secondary end-point• MACCE at 2 months and one year

• Procedural releated factors (Radiation, Contrast, Hospitalisation)

Page 6: E-poster07 Ruzsa aimradial20170921 Snuff box access

Ultrasonography

• Vivid 5 US

• US guided puncture in all cases

• US dimensions: distal RA diameter, calcification

• Control US on the next postoperative day

Page 7: E-poster07 Ruzsa aimradial20170921 Snuff box access

Coronary angiography and intervention• US guided puncture

• 5F TR sheath

• 5F diagnostic catheter

• PCI with 5F guiding (Launcher) or 6.5F sheathless guidingcatheter

• Rotational atherectomy with 1.25 mm Burr

• Bifurcation strategy: T stent and TAP

• CTO: Biradial access- for left 5F and for right 7F sheathless

• FFR measurement – 5F guiding

• IVUS- 5F Boston or 6F Volcano but with 6.5 F sheathless

Page 8: E-poster07 Ruzsa aimradial20170921 Snuff box access

Postoperative management

Compression bandage for 4 hours

Page 9: E-poster07 Ruzsa aimradial20170921 Snuff box access

Results

• 150 pts

• 100% success and no cross over to femoral access site

• 5F guiding or diagnostic catheter in 108 cases and 6.5F guiding in 42 patients

• Procedure releted factors• Mean contrast consumption. 115 [86-14.3] ml

• DAP: 34.8 [18.7-51.5] Gy

• Fluoroscopy time 7.1 [4.5-9-8] minute

• Hospitalisation 0.6 day

Page 10: E-poster07 Ruzsa aimradial20170921 Snuff box access

Complications

• Vascular complications• Radial artery occlusion 0%

• Forearm haematoma 1/150 (0.6%)

• MACCE• No MACCE at one month

Page 11: E-poster07 Ruzsa aimradial20170921 Snuff box access

Limitations and advantages

• Limitations• RAO is the major limitation• Left arm must straighten !!!!• Due to 5F guiding many techniques are not available therefore we need new

strategy in bifurcation, left main, CTO, calcification• 6.5 sheathless guiding has the same uter diameter as the 5F sheath

• Advantages• Compression is very easy• Fast ambulation (4h ??, 2 h)• For CTO cases the left arm position is comfortable and the operateur radiation

is low

Page 12: E-poster07 Ruzsa aimradial20170921 Snuff box access

Limitation - RAO

Page 13: E-poster07 Ruzsa aimradial20170921 Snuff box access

LAD Rotablationand BVS implantation

Page 14: E-poster07 Ruzsa aimradial20170921 Snuff box access

Current clinical admission

• CCS 3 angina

• Rutherford class 3 claudication

• Positive stress test

• Positive stress echo

• Echo: inferior hypokinesis

Plan: - LAD PCI via right radial access (snuff box)- Right coronary CTO recanalisation??

Page 15: E-poster07 Ruzsa aimradial20170921 Snuff box access

US guided radial artery puncture

Page 16: E-poster07 Ruzsa aimradial20170921 Snuff box access

Coronary angiography 2017.03 Right radial artery recanalisation(US guided- snuff box)

Page 17: E-poster07 Ruzsa aimradial20170921 Snuff box access

1. LAD PCI 2017.03

Page 18: E-poster07 Ruzsa aimradial20170921 Snuff box access

2. RCA stent CTO recanalisation

Page 19: E-poster07 Ruzsa aimradial20170921 Snuff box access

RCA CTO recanalisation

Page 20: E-poster07 Ruzsa aimradial20170921 Snuff box access

What to do??- Bilateral angiography5F left radial JL3.5

Caravel microcatheterMiracle Bross

Page 21: E-poster07 Ruzsa aimradial20170921 Snuff box access

Selective angiography

Page 22: E-poster07 Ruzsa aimradial20170921 Snuff box access

Contralateral angio

Page 23: E-poster07 Ruzsa aimradial20170921 Snuff box access

Pd or PL branch??

Page 24: E-poster07 Ruzsa aimradial20170921 Snuff box access

RCA PD ballooning

Page 25: E-poster07 Ruzsa aimradial20170921 Snuff box access

RCA ballooning

Page 26: E-poster07 Ruzsa aimradial20170921 Snuff box access

RCA stenting

Onyx 3.5x18, Onyx 3x32, Onyx 2.75x28, Onyx 2.5x18 mm

Page 27: E-poster07 Ruzsa aimradial20170921 Snuff box access

Final angiography

Page 28: E-poster07 Ruzsa aimradial20170921 Snuff box access

Conclusion

• Ultrasound guided distal transradial access from the snuff box area is safe and effective and the rate of radial artery occlusion is extremely low