e air force standard design as indicated ......attached kennel layout - no dog house (single loaded)...

8
USE THESE DOCUMENTS IN CONJUCTION WITH THE STANDARD DESIGN DOCUMENT AND INTERACTIVE PROGRAMMING WORKSHEET. GENERAL NOTES 1. 1 F PHASE: SCALE: SHEET NUMBER AIR FORCE CIVIL ENGINEER CENTER 2 3 4 5 6 7 8 9 E D C B A NOT FOR CONSTRUCTION DATE: AS INDICATED C-1 COVER SHEET ANY AFB, CONUS CIVIL ENGINEER SQUADRON: MILITARY WORKING DOG FINAL JUNE 2018 DRAWING LIST NUMBER NAME C-1 COVER SHEET A-1 STANDARD DESIGN PLAN - 1 A-2 STANDARD DESIGN PLAN - 2 A-3 MODULES A, B, & C PLANS & AXONS A-4 MODULES D PLANS & AXONS A-5 MODULES E & F PLANS & AXONS A-6 MODULE G PLANS & AXONS A-7 TRAINING EQUIPMENT AIR FORCE STANDARD DESIGN MILITARY WORKING DOG FACILITY JUNE 2018

Upload: others

Post on 13-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

USE THESE DOCUMENTS IN CONJUCTION WITH THE STANDARD DESIGN DOCUMENT AND INTERACTIVE PROGRAMMING WORKSHEET.

GENERAL NOTES

1.

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

C-1

CO

VER

SH

EET

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

DRAWING LIST

NUMBER NAMEC-1 COVER SHEETA-1 STANDARD DESIGN PLAN - 1A-2 STANDARD DESIGN PLAN - 2A-3 MODULES A, B, & C PLANS & AXONSA-4 MODULES D PLANS & AXONSA-5 MODULES E & F PLANS & AXONSA-6 MODULE G PLANS & AXONSA-7 TRAINING EQUIPMENT

AIR FORCE STANDARD DESIGNMILITARY WORKING DOG FACILITY

JUNE 2018

Page 2: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

THIS BASIS OF DESIGN CONCEPT FLOOR PLAN IS BASED ON THE APPROVED FUNCTIONAL ADJACENCY DIAGRAM. THE ROOM CRITERIA IS LOCATED IN THE ROOM DATA SHEETS IN THE STANDARD DESIGN DOCUMENT AND THE ROOM SIZES ARE LOCATED IN THE INTERACTIVE PROGRAMMING WORKSHEET. THE OVERALL DIMENSIONS ARE APPROXIMATE AS THE BASIS OF DESIGN CONCEPT PLAN DOES NOT INDICATE STRUCTURAL ELEMENTS, ALL PLUMBING CHASES , MISCELLANEOUS UTILITY ROOMS ( MECHNICAL, ELECTRICAL, COMMUNICATIONS) OR WALL THICKNESSES, ETC. MODULE LEGEND

A - ADMINISTRATION

B - SPECIAL USE

C - COMMON USE / SUPPORT

D - KENNEL

E - TOILET

F - BUILDING SUPPORT

G - OUTDOOR SUPPORT

CIRCULATION

A1A3

E3 C1

C2

F2 F3

B4

F1

B3

B1 B2

D3

D2

D1E1 E2A2

D5

D4

D5

D6

D7

68' -

0"60

' - 0"

32' -

0"

174' - 6"

57' - 6"99' - 0"

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-1

STAN

DAR

D D

ESIG

NPL

AN -

1

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

STANDARD DESIGN PLAN 10 8' 16' 32'

SCALE:1/16"=1'

Page 3: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

MODULE LEGEND

A - ADMINISTRATION

B - SPECIAL USE

C - COMMON USE /SUPPORT

D - KENNEL

E - TOILET

F - BUILDINGSUPPORT

G - OUTDOORSUPPORT

CIRCULATION

A1A3

E3 C1

C2

F2 F3

B4

F1

B3

B1 B2

D3D2D1

E1 E2A2

D4

D7

D6

99' -

0"

60' -

0"

111' - 0" 46' - 0"

THIS BASIS OF DESIGN CONCEPT FLOOR PLAN IS BASED ON THE APPROVED FUNCTIONAL ADJACENCY DIAGRAM. THE ROOM CRITERIA IS LOCATED IN THE ROOM DATA SHEETS IN THE STANDARD DESIGN DOCUMENT AND THE ROOM SIZES ARE LOCATED IN THE INTERACTIVE PROGRAMMING WORKSHEET. THE OVERALL DIMENSIONS ARE APPROXIMATE AS THE BASIS OF DESIGN CONCEPT PLAN DOES NOT INDICATE STRUCTURAL ELEMENTS, ALL PLUMBING CHASES , MISCELLANEOUS UTILITY ROOMS ( MECHNICAL, ELECTRICAL, COMMUNICATIONS) OR WALL THICKNESSES, ETC.

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-2

STAN

DAR

D D

ESIG

NPL

AN -

2

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

STANDARD DESIGN PLAN 20 8' 16' 32'

SCALE:1/16"=1'

Page 4: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

A3

A1A2

B1 B2

B3 B4

C1

C2

G G

F

BA

D

E C

AB

C

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-3

MO

DU

LES

A, B

, & C

PLAN

S &

AXO

NS

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

MODULE A:ADMINISTRATION0 8' 16' 32'

SCALE:1/16"=1'

MODULE B:SPECIAL USE

MODULE C:COMMON USE / SUPPORT

0 8' 16' 32'

SCALE:1/16"=1'

TOTAL AREA OF MODULE = 1,615 NET SF

A1 KENNEL MASTERA2 TRAINERS

B1 TACK ROOMB2 FOOD STORAGE & PREPARATION

C1 TA-50 LOCKER ROOM

TOTAL AREA OF MODULE = 1,125 NET SF

TOTAL AREA OF MODULE = 925 NET SF

KEYPLAN

C2 MULTI-PURPOSE ROOM

0 8' 16' 32'

SCALE:1/16"=1'

A3 HANDLERS

B3 EXAM ROOMB4 SURGERY

Page 5: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

D3

D1

D2

D3

D2

D4

D5

D5

D7

D6

G G

F

BA

D

E C

AB

C

D3D2D1

D4

D7

D6

D3D2

D4

D7

D6D3

D2

D1

D4

D5

D5

D7

D6

D3

D2

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-4

MO

DU

LES

D P

LAN

S &

AXO

NS

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

D1 DOG HOUSED2 INDOOR KENNELD3 OUTDOOR KENNEL

TOTAL AREA OF MODULE = 3,650 NET SF0 8' 16' 32'

SCALE:1/16"=1'

KEYPLAN

MODULE D:KENNEL

D4 KENNEL CORRIDOR

ATTACHED KENNEL LAYOUT - W/ DOG HOUSE(DOUBLE LOADED)

DETACHED KENNEL LAYOUT - W/OUT DOG HOUSE(DOUBLE LOADED)

DETACHED KENNEL LAYOUT - W/ DOG HOUSE

(SINGLE LOADED)

ATTACHED KENNEL LAYOUT - NO DOG HOUSE(SINGLE LOADED)

*TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL

REQUIRED

CONCEPTUAL BASIS OF DESIGN

D5 EXTERIOR KENNEL CORRIDORD6 WET STORAGED7 DRY STORAGE

Page 6: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

F1 F3F2

E1 E2 E3

G G

F

BA

D

E C

AB

C

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-5

MO

DU

LES

E &

FPL

ANS

& AX

ON

S

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

MODULE F:BUILDING SUPPORT

MODULE E:TOILET,SHOWER, LOCKER

F2 MECHANICAL ROOMF3 ELECTRICAL ROOM

F1 IT/COMMUNICATIONS ROOM

TOTAL AREA OF MODULE = 535 NET SF *

*BUILDING SUPPORT AREAS ARE ESTIMATES ONLY AND ACTUAL SIZE IS DEPENDENT ON REQUIREMENTS

FOR CLIMATE ZONE, LOCATION, SYSTEM, ETC. (SQ. FT. NOT INCLUDED IN TOTAL CONCEPT PLAN NET

FLOOR AREA AS THIS AREA IS INCLUDED IN NET TO GROSS MULTIPLIER OF 25%)

TOTAL AREA OF MODULE = 685 NET SF

E1 MEN'S TOILET,SHOWER, LOCKERE2 WOMEN'S TOILET,SHOWER, LOCKER

0 8' 16' 32'

SCALE:1/16"=1'

0 8' 16' 32'

SCALE:1/16"=1'

E3 JANITOR

Page 7: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

G1G4

G2 G3

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-6

MO

DU

LE G

PLA

NS

&AX

ON

S

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

MODULE G:OUTDOOR SUPPORT

G1 OUTDOOR STORAGE G2 DOG BREAK AREA

G4 OBEDIENCE COURSE

G3 OPTIONAL PORTABLE EXPLOSIVE STORAGE

Page 8: E AIR FORCE STANDARD DESIGN AS INDICATED ......ATTACHED KENNEL LAYOUT - NO DOG HOUSE (SINGLE LOADED) *TOTAL AREA MAY VARY BASED ON LAYOUT ARRANGEMENT AND TOTAL NUMBER OF KENNEL REQUIRED

1

F

PHAS

E:

SCAL

E:

SHEET NUMBER

AIR

FO

RC

ECI

VIL

ENG

INEE

R

CENT

ER

2 3 4 5 6 7 8 9

E

D

C

B

A

NOT FOR CONSTRUCTION

DATE

:

AS I

NDIC

ATED

A-7

TRAI

NIN

GEQ

UIP

MEN

T

ANY

AFB,

CO

NU

S

CIVI

L EN

GIN

EER

SQUA

DRO

N:M

ILIT

ARY

WO

RKIN

G D

OG

FIN

AL

JUN

E 2

018

TRAINING EQUIPMENT

CONCRETE DOG WALK WOOD DOG WALK

CONCRETE TUNNELOPTIONAL BLEACHERS

METAL TUNNEL BARRELS

CONCRETE STAIRS WOOD STAIRS

CONCRETE A - FRAME WOOD A - FRAME

CONCRETE WINDOW WOOD JUMP/HURDLECONCRETE JUMP/HURDLE WOOD WINDOW