e-100-a and e-100-l-a - applied products tpgapplied-tpg.com/media/8499/e_100_a_e_100_l_a_ds.pdf ·...

4
H56829 2/12 www.tycothermal.com 1 of 3 1. Self- Regulat- ing Cables 14. Index 2. Power- Limiting Cables 3. Mineral Insulated Cables 4. Longline Heating 5. Tubing Bundles 6. Tank Heating 7. Snow and Ice 8. Control and Monitoring 9. Heat-Trace Panels 10. Engineered Products 11. Steam- Tracing Systems 12. Technical Data Sheets 13. Appendixes E-100-A and E-100-L-A Visit www.tycothermal.com for more information on our ten-year extended warranty. End seal and lighted end seal kits The E-100-A and E-100-L-A serve as above- insulation end seal kits for Raychem brand BTV, QTVR, XTV, KTV, or VPL heating cables. They are approved by FM and CSA for use in hazardous locations. Both the E-100-A and the E-100-L-A are mounted on the pipe and project through the thermal insulation and cladding for ease of maintenance. The E-100-L-A end seal with signal light uses an array of bright LEDs for exceptional visibility and long product life. These rugged end seals are made from high- performance engineering polymer and resist impact, high temperature, and chemical and UV exposure. The stand allows for up to four inches (100 mm) of thermal insulation. The encapsulated light and boot reliably prevent moisture and dust ingress. The industrial- grade electronics used in the E-100-L-A are encapsulated. Both the E-100-A and E-100-L-A are re-enter- able, allowing easy access for testing. Voltage and continuity checks can be done by simply unscrewing the E-100-A cap and removing the reusable sealing boot. The E-100-L-A makes maintenance even easier by allowing for visual inspection of heating circuit continuity. The E-100-L-A is available in two voltages and can be retrofitted into previously installed E-100-A end seals. The light module is replaceable. The kits contain all the necessary materials for a complete installation except for one pipe strap, which must be ordered separately. E-100-A E-100-L-A E-100-A E-100-L-A Description Above-insulation end seal, cold-applied Above-insulation end seal with red signal light, cold-applied *Not for use with 480 V VPL Kit Contents Note: Order appropriate pipe strap separately (one per kit) 1 end seal 1 end seal with red indicator light

Upload: dinhcong

Post on 20-Jan-2019

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E-100-A and E-100-L-A - Applied Products TPGapplied-tpg.com/media/8499/E_100_A_E_100_L_A_DS.pdf · BR-Ex e II E-100-A E-100-L-A ... Frostex Plus, Frostguard, FroStop, FSE, Gardian,

H56829 2/12 www.tycothermal.com 1 of 3

1. Self- Regulat- ing Cables

14. Index2. Pow

er- Lim

iting Cables

3. Mineral

Insulated Cables

4. Longline Heating

5. Tubing Bundles

6. Tank Heating

7. Snow and

Ice8. Control and

Monitoring

9. Heat-Trace Panels

10. Engineered Products

11. Steam-

Tracing System

s

12. Technical Data Sheets

13. Appendixes

E-100-A and E-100-L-A

Visit www.tycothermal.com for more information on our ten-year extended warranty.

End seal and lighted end seal kits

The E-100-A and E-100-L-A serve as above-insulation end seal kits for Raychem brand BTV, QTVR, XTV, KTV, or VPL heating cables. They are approved by FM and CSA for use in hazardous locations.

Both the E-100-A and the E-100-L-A are mounted on the pipe and project through the thermal insulation and cladding for ease of maintenance. The E-100-L-A end seal with signal light uses an array of bright LEDs for exceptional visibility and long product life.

These rugged end seals are made from high-performance engineering polymer and resist impact, high temperature, and chemical and UV exposure. The stand allows for up to four inches (100 mm) of thermal insulation. The encapsulated light and boot reliably prevent moisture and dust ingress. The industrial-grade electronics used in the E-100-L-A are encapsulated.

Both the E-100-A and E-100-L-A are re-enter-able, allowing easy access for testing. Voltage

and continuity checks can be done by simply unscrewing the E-100-A cap and removing the reusable sealing boot. The E-100-L-A makes maintenance even easier by allowing for visual inspection of heating circuit continuity. The E-100-L-A is available in two voltages and can be retrofitted into previously installed E-100-A end seals. The light module is replaceable.

The kits contain all the necessary materials for a complete installation except for one pipe strap, which must be ordered separately.

E-100-A E-100-L-A

E-100-A E-100-L-A

Description Above-insulation end seal, cold-applied Above-insulation end seal with red signal light, cold-applied*Not for use with 480 V VPL

Kit Contents

Note: Order appropriate pipe strap separately (one per kit)

1 end seal 1 end seal with red indicator light

Page 2: E-100-A and E-100-L-A - Applied Products TPGapplied-tpg.com/media/8499/E_100_A_E_100_L_A_DS.pdf · BR-Ex e II E-100-A E-100-L-A ... Frostex Plus, Frostguard, FroStop, FSE, Gardian,

E-100-A AND E-100-L-A

2 of 3 www.tycothermal.com H56829 2/12

E-100-A E-100-L-A

ApprovalsClass I, Div. 2, Groups A, B, C, DClass II, Div. 1 and 2, Groups E, F, GClass III

CLI, ZN1, AEx e II T(2)

Hazardous Locations

(1)

(1) Except VPL(2) For T-rating, see heating cable or design documentation

Ex e II T(2) Ex em II T(2)

Class I, Div. 2, Groups A, B, C, DClass II, Div. 1 and 2, Groups E, F, GClass III

CLI, ZN1, AEx em II T(2)

Hazardous Locations

(1)

IECEx PTB 09.0038UEx e ll Ex tD A21 IP66

IECEx PTB 09.0038UEx emb llEx tD mbD A21 IP66

09-IEx-0004XBR-Ex e II

-ws

-ws

-ws

-ws

09-IEx-0004XBR-Ex e II

E-100-A E-100-L-A

Product Specifications

Heating cable capability BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT and VPL-CT

Ingress protection NEMA 4X (IP65) NEMA 4X (IP65)

Minimum installation temperature –40°F (–40°C) –40°F (–40°C)

Minimum ambient temperature –75°F (–60°C) –40°F (–40°C)

Maximum ambient temperature 132°F (56°C) 104°F (40°C)

Maximum pipe temperature 500°F (260°C) 500°F (260°C)

Maximum operating voltage 480 Vac 120 / 277 Vac

Overall height 7 in (175 mm) 8 in (200 mm)

Outer diameter at insulation 2.0 in (50 mm)Usable with up to 4 in (100 mm) thermal insulation

3 in (75 mm)

Materials High-performance glass-filled engineered polymer

High-performance glass-filled engineered polymer

Light source Super-bright light-emitting diodes (LEDs), red

Light source power supply Not applicable Linear (nonswitching)

Power consumption 0 W < 2 W

Ordering Details

End seal

Catalog number E-100-A (100–480 Vac)

E-100-L1-A (100–120 Vac)

E-100-L2-A (200–277 Vac)

Part number 046567-000 583377-000 478767-000

Weight 0.6 lb (272 g) 1.3 lb (630 g) 1.3 lb (630 g)

Spare boot pack for E-100

Catalog number E-100-BOOT-5-PACK

Part number 281053-000

Pack weight 0.25 lb (140 g)

Pack contents Five sealant-filled boots and five cable ties

Page 3: E-100-A and E-100-L-A - Applied Products TPGapplied-tpg.com/media/8499/E_100_A_E_100_L_A_DS.pdf · BR-Ex e II E-100-A E-100-L-A ... Frostex Plus, Frostguard, FroStop, FSE, Gardian,

E-100-A AND E-100-L-A

H56829 2/12 www.tycothermal.com 3 of 3

1. Self- Regulat- ing Cables

14. Index2. Pow

er- Lim

iting Cables

3. Mineral

Insulated Cables

4. Longline Heating

5. Tubing Bundles

6. Tank Heating

7. Snow and

Ice8. Control and

Monitoring

9. Heat-Trace Panels

10. Engineered Products

11. Steam-

Tracing System

s

12. Technical Data Sheets

13. Appendixes

Ordering Details

End seal

Replacement indicator light for E-100-LXX-A

Catalog number E-100-LR1-A (100–120 Vac)

E-100-LR2-A (200–277 Vac)

Part number 552225-000 874485-000

Weight 0.9 lb (450 g) 0.9 lb (450 g)

Page 4: E-100-A and E-100-L-A - Applied Products TPGapplied-tpg.com/media/8499/E_100_A_E_100_L_A_DS.pdf · BR-Ex e II E-100-A E-100-L-A ... Frostex Plus, Frostguard, FroStop, FSE, Gardian,

© 2

012

Tyc

o Th

erm

al C

ontro

ls L

LC

Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls' only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes—without notification to Buyer—to processing or materials that do not affect compliance with any applicable specification.

Worldwide HeadquartersTyco Thermal Controls7433 Harwin DriveHouston, TX 77036USATel: 800-545-6258Tel: 650-216-1526Fax: 800-527-5703Fax: [email protected]

Europe, Middle East, AfricaTyco Thermal ControlsRomeinse straat 143001 LeuvenBelgië / BelgiqueTel: +32 16 213 511Fax: +32 16 213 603

CanadaTyco Thermal Controls250 West St.Trenton, Ontario K8V 5S2CanadaTel: 800-545-6258Fax: 800-527-5703Tel: 613-392-6571Fax: 613-392-3999

Latin AmericaTyco Thermal ControlsAl. Araguaia, 2044 – Sala.1101, Bloco BEdificio CEA – AlphavilleBarueri – Sao Paulo – Brasil06455-000Tel: +55 11 2588 1400Fax: +55 11 2588 1410

Asia PacificTyco Thermal Controls20F, Innovation Building,1009 Yi Shan Rd,Shanghai 200233, P.R.ChinaTel: +86 21 2412 1688Fax: +86 21 5426 2937 / 5426 3167

Tyco, Alliance Integrated Systems, AMC, AutoMatrix, AutoSol, BTV, CapaciSense, Chemelex, DHSX, DigiTrace, DigiTrace logo, DigiTrace Supervisor, Duoterm, ElectroMelt, EM2XR, FHSM, FHSC, FlexFit, FlexiClic, Flowguard, FreezeTrace, FreezGard, Frostex, Frostex Plus, Frostguard, FroStop, FSE, Gardian, HAK, Handvise, HBTV, HCCL, HotCap, HQTV, HTPG, HTPI, HWAT, HXTV, IceStop, Interlock, Isocable, Isodrum, Isoheat, Isomantle, Isopad, Isopad Frostguard, Isopad logo, Isopanel, Isotape, Isotherm, JBM, JBS, K-Flex, K-Flex logo, KHE, KHH, KHL, KHP, KTV, Labsafe, LBTV, LHC, LHFV, LHRV, Metabond, Mini WinterGard, Miser WinterGard, MoniTrace, Multi-plus, NGC, PetroTrace, PLI, PolyMatrix, Pyro CiC, PyroFLX, Pyromaster, Pyropak, Pyrosil, PyroSizer, Pyrotenax, Pyrotenax Designer, Pyrotenax logo, QTVR, QuickNet, QuickNet logo, QuickStat, QuickTerm, RayClic, RaySol, RayStat, Retro WinterGard, RHS, RHSC, RHSM, RMM2, SBF, SBV, SC, SHC, Sheathmaster, ShowerGuard, SLBTV, Smart Heat for Comfort and Safety, SnoCalc, SnoCalc logo, STS, System 500, System 1850, System 1850-SE, System 2000, System 2200, T2, T2 logo, T2Blue, T2QuickNet, T2Red, T2Reflecta, TankCalc Plus, TempBus, Thermoheat, ThermoLimit, Thermo-Line, Total Care in Heat-tracing, Touch, Trac-Loc, Trac Calc, TraceCalc Net, TraceCalc Net logo, TraceCalc Pro logo, TraceGuard 277, TraceMaster, Tracer, Tracer logo, TRACERLYNX, TRACERLYNX logo, TraceStat, TraceTek, TraceTek logo, TruckPak, VLBTV, VLKTV, VPL, We manage the heat you need, WinterGard, WinterGard logo, WinterGard Plus, WinterGard Wet, XL-ERATE, XL-ERATE logo, XL-Trace, XTV and Zero EMI are registered and/or unregistered trademarks of Tyco Thermal Controls LLC or its affiliates.

All other trademarks are the property of their respective owners.