2PDT
20A, 120/277 V DIMMER SWITCH
GENERAL NOTES:
20A, 120/277 V SWITCH
20A, 120/277 V SWITCH
20A, 120/277 V SWITCH
20A, 120/277 V SWITCH
4 WAY
3 WAY
SPST
10-50 R
5-20 R
5-20 R
1-15 R
125/250V, 3P, SIMPLEX, 3W,
125V, 2P, DUPLEX, 3W
125V, 2P, SIMPLEX, 3W
125V, 2P, SIMPLEX,
DESCRIPTIONSYMBOL
BACKGROUND PLAN AND ONE LINE SYMBOLS
LOW VOLTAGE DISCONNECT SWITCH
DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL
SEE CIRCUITS FOR SPECIFIC TYPE
CONTROL SWITCH (SEL. OR P.B.)
C
3,
4
2P
D
EMERGENCY BATTERY PACK
HIGH INTENSITY DISCHARGE LIGHT
INCANDESCENT LUMINAIRE
FLUORESCENT LUMINAIRE
EM
K
CP
JB
HS
DS
LB
A
R
SEE CIRCUITS FOR SPECIFIC TYPE
FLOAT SWITCH
TEMPERATURE SWITCH OR RTD
LIMIT - PRESSURE - VACUUM SWITCH
ELECTRICAL OR MECHANICAL ALTERNATOR
(SEE WIRING)
OVERLOAD SWITCH OR DEVICE
TERMINAL BOX
PHOTOCELL LINE VOLTAGE
INTERCOMMUNICATION SYSTEM
AMPLIFIER - WALL STATION - LINE BALANCE
INTERCOMMUNICATION DESK SET
INTERCOM. SPEAKER (SURFACE MTD.)
INTERCOM. SPEAKER (CEILING LAY-IN)
TELEPHONE OUTLET OR JUNCTION BOX
WELDING RECEPTACLE - NEMA L9-50R
600V, 2P, 3W, SIMPLEX
LOW VOLTAGE FUSE (BELOW 600V)
(2S,2W) TWO SPEED, TWO WINDING
600V, 3 POLE MOLDED CASE CIRCUIT
BREAKER, FRAME & RATING AS SHOWN
SINGLE PHASE, FRACTIONAL HP MOTOR
THREE PHASE LOAD WITH IDENTIFICATION
HIGH VOLTAGE FUSE (ABOVE 600 V)
TAG NO. (BALLOON) FOR DEVICE INDICATED
FOR POWER (SEE GEN. NOTE 4)
3/4"C(2/C#18 SHLD.)CONDUIT AND WIRE
RUN FROM DEVICE INDICATED TO
LOCATION INDICATED
CAPACITOR, 3 PHASE, SIZE AS INDICATED
DISCONNECT SWITCH
(F) = FUSED (C) = CIRCUIT BREAKER
(BACKGROUND DRAWINGS ONLY)
FUSED UNLESS NOTED (CIRCUIT BREAKER)
COMBINATION LIGHTING CONTACTOR
WITH HAND-OFF-AUTO SWITCH
MANUAL STARTER
(R) = REVERSING
CONTROL PANEL
TEMPERATURE CONTROL PANEL
UNIT HEATER, 1/8 HORSEPOWER
600 VOLT FEEDER BUS DUCT
(AMPERAGE AS INDICATED)
LIGHTNING ARRESTOR
NEMA 4 WATERTIGHT
NEMA 4X WATERTIGHT AND CORROSION PROOF
NEMA 7
EXPLOSION PROOF -
CLASS I, DIVISION I, GROUP D
NEMA 9
EXPLOSION PROOF -
CLASS II, DIVISION 1
AS NOTED (LIGHTING PANEL, CONTROL PANEL,
DISTRIBUTION PANEL ETC.) WALL MOUNTED
JUNCTION BOX
HEATER
CABLE REEL
TRANSFORMER
CONDUIT WITH CONDUIT SEAL FITTING
CONDUIT EXPOSED
CONDUIT CONCEALED / UNDERGROUND
1 2 3
4 5 6
CONCRETE ENCASED DUCT BANK, WITH
CABLE LOCATIONS AND SPARE DUCTS AS
INDICATED ON DRAWINGS
LOW VOLTAGE HOME RUNS
120/208 V 120/240 V (SEE GEN. NOTE 4)
2S,2W
SIZE 2
UH-19
BUS DUCT
THERMAL SWITCH
VFD LOCK OUT SWITCH
INTERCOM HANDSET - SURFACE MOUNTED
WITH REMOTE SPEAKER AMPLIFIER
TO LOCATION INDICATED (SEE GEN. NOTE 4)
MAGNETIC STARTER
COMBINATION MAGNETIC STARTER
EXIT LIGHT
KEYLOCK
OVERHEAD LINE
CONCRETE ENCASED UNDERGROUND DUCT BANK
SD
3
FVR
2
RV
1
(RV) REDUCED VOLTAGE
(FVR) FULL VOLTAGE REVERSING
OTHERWISE INDICATED
VOLTAGE NON-REVERSING UNLESS
ALL STARTERS SHALL BE FULL
DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL
LATCHING CABLE SWITCH
U
CR
L
CR
T
ETI
1
O
R
PRESS. ACTUATED SWITCH
FLOAT ACTUATED SWITCH
FLOW ACTUATED SWITCH
TEMP. ACTUATED SWITCH
TIME-DELAY FUSE
CONTROL RELAY COIL
TWO COIL LATCHING RELAY
TIMING RELAY COIL
120 VAC TRANSFORMER
SELECTOR SWITCH OPERATOR
WITH FUNCTION SHOWN
FIELD LOCATED STOP BUTTON
SOLENOID OR CLUTCH
ELAPSED TIME INDICATOR
MAINTAINED PUSH-PULL
OPERATOR
MAINTAINED STOP-START
PUSHBUTTON OPERATOR
ZERO SPEED OR ANTI-
PLUGGING SWITCH
LIMIT SWITCH-
NORMALLY OPEN
LIMIT SWITCH-
NORMALLY CLOSED
LIMIT SWITCH-NORMALLY
CLOSED-HELD OPEN
LIMIT SWITCH-NORMALLY
OPEN-HELD CLOSED
CONTROL RELAY
CONTACT-NORMALLY OPEN
CONTROL RELAY
CONTACT-NORMALLY CLOSED
TIMED CLOSED CONTACT
ON ENERGIZATION
TIMED OPEN CONTACT
ON ENERGIZATION
TIMED OPEN CONTACT
ON DE-ENERGIZATION
TIMED CLOSED CONTACT
ON DE-ENERGIZATION
MOMENTARY PUSHBUTTON
OPERATOR-NORMALLY OPEN
MOMENTARY PUSHBUTTON
OPERATOR-NORMALLY CLOSED
PUSHBUTTON OPERATOR
WITH MUSHROOM HEAD
PUSH-TO-TEST
INDICATING LIGHT
MAINTAINED STOP-
MOMENTARY START
PUSHBUTTON (JOG)
LOCAL TERMINALS WITH
EXTERNAL WIRING
TIMING RELAY
H A
INST.
INST.
CR
INSTANTANEOUS CONTACTS
CONTROL CIRCUIT & PILOT DEVICE LEGEND
F
T
L P V
ALT
OS
TB
PC
1. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN LIGHT LINE WEIGHTS ON THE DRAWINGS
ARE EXISTING ITEMS TO REMAIN. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN HEAVY
LINE WEIGHTS ARE NEW UNDER THIS CONTRACT.
2. ITEMS SHOWN CROSSHATCHED ON THE DRAWINGS ARE EXISTING ITEMS TO BE REMOVED.
3. FOR ITEMS INDICATED AS "FIELD LOCATE" CHECK DRAWINGS OF OTHER TRADES (IN PARTICULAR
PIPING AND STRUCTURAL) FOR INTERFERENCE AND FOR LOCATIONS OF MOUNTING FLANGES,
CONNECTION POINTS, ETC.
4. INSTALL A SINGLE CONDUCTOR INSULATED (RHW, THHN, OR XHHW) COPPER GROUND WIRE IN EACH
CONDUIT, SIZE AS SHOWN ON DRAWINGS OR AS A MINIMUM PER THE NATIONAL ELECTRICAL CODE.
THIS GROUND WIRE SHALL BE CONNECTED AT EACH END TO THE EQUIPMENT GROUND.
5. THE FOLLOWING COMPONENT IDENTIFICATION SHALL BE USED AS APPROPRIATE:
(F) FIELD MOUNTED, NOT AT STARTER OR OTHER CONTROL PANELS.
(S) STARTER PANEL MOUNTED.
(MCP) AT MAIN CONTROL PANEL.
(1) AT CONTROL PANEL NO. 1
(2) AT CONTROL PANEL NO. 2
(TCP) AT TEMPERATURE CONTROL PANEL.
6. EQUIPMENT SHOWN INSIDE SHALL BE RATED NEMA 12 AND EQUIPMENT SHOWN OUTSIDE SHALL BE
RATED NEMA 4X, STAINLESS STEEL UNLESS OTHERWISE INDICATED.
7. MINIMUM CONTROL WIRE SIZE SHALL BE EITHER #14 AWG OR 2/C#18SH AND MINIMUM POWER WIRE
SIZE SHALL BE #12 AWG, UNLESS OTHERWISE INDICATED.
8. MINIMUM CONDUIT SIZE SHALL BE 1", UNLESS OTHERWISE INDICATED.
9. PROVIDE INSULATED CONDUCTORS PER SPECIFICATION 16120.
10. PROVIDE 20% SPARE I/O MINIMUM FOR EACH DISCRETE AND ANALOG TYPE PER PANEL, UNLESS
OTHERWISE INDICATED.
11. WIRE NUMBERS (1,3 & 5) ETC. SHALL BE PREFIXED WITH STARTER TAG NUMBERS. THE WIRE NUMBER
AFTER THE PREFIX, MAY BE THE MANUFACTURERS WIRE NUMBERING SYSTEM. WIRE MARKERS MAY
BE USED AT EACH WIRE TERMINATION POINT.
12. PROVIDE 316-STAINLESS STEEL FOR NEMA 4X AREAS, UNLESS NOTED OTHERWISE.
13. HOMERUNS SHALL BE MINIMUM 1"C(2#12, 1#12) UNLESS NOTED OTHERWISE.
14. ALL CONDUITS (INCLUDING POWER AND CONTROL CONDUITS) BELOW GRADE SHALL BE CONCRETE
ENCASED WITH RED DYE ON TOP OF DUCT BANK.
15. CONTRACTOR SHALL VERIFY ALL CONDUIT SIZES MEET NEC CONDUIT FILL REQUIREMENTS.
16. ALL DOOR INTRUSIONS SWITCH CONTACTS SHALL BE 24 VOLTS DC.
17. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2011 NEC.
SMOKE DETECTOR
GROUND
DS
DOOR INTRUSION SWITCH 24V CONTACT.
a
3-DESIGNATES 3-WAY SWITCHING,
a-DESIGNATES CONTROLING "a" FIXTURES ONLY
COPPER-CLAD GROUND ROD
EXIT
CS
HORN/STROBE (110CD)
CLOCK
HANGER
RANGE
TYPE
TS
LOC
MOTOR SPACE HEATER
MSH
POLE MOUNTED SITE LIGHT FIXTURE
WIRING DEVICE SCHEDULE
NEMA TYPE
SOLENOID VALVE
FLOW SWITCHFS
304 ITEM NO. INTERCOM EQUIPMENT
LOUVER DAMPER ACTUATOR
MD
600V, 2P, 3W, SIMPLEX WELDING
5-15R
125V, 2P, MULTI-RECEPTACLE
6-50R250V, 2P, SIMPLEX, 3W, 50A
6-20R
L14-20R
208V, 3P, SIMPLEX, 4W, LOCKING
L9-50R
250V, 2P, SIMPLEX, 3W, 20A
277V, 2P, DUPLEX, 3W
7-15R
20A, 120/277 V SWITCH - MOTOR RATED
M
SPST
ST
SHUNT TRIP PUSH BUTTON
C
CONTACTOR
50/51
MEDIUM VOLTAGE OVERLOAD REALY
AS
AMP SELECTOR SWITCH
AM
AMMETER
52
CS
MEDIUM VOLTAGE DRAWOUT BREAKER
STATION ARRESTOR
SURGE ARRESTOR
KKIRK KEY
SPDSURGE PROTECTION DEVICE
VFDVARIABLE FREQUENCY DRIVE
SOLID STATE SOFT STARTERSS
M
LOW VOLTAGE MOTION SENSOR- DUAL TECHNOLOGY,
CEILING MOUNTED
PP
LINE VOLTAGE SWITCH PACK WITH LOW VOLTAGE POWER
SUPPLY FOR SENSORS
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/2
1/2
01
7 9
:3
1:4
3 A
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-0
01
E
LE
CT
RIC
AL
L
EG
EN
D.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-001
ELE
CT
RIC
AL LE
GE
ND
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:0
4:3
3 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-0
02
E
LE
CT
RIC
AL
A
BB
RE
VIA
TIO
NS
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-002
ELE
CT
RIC
AL
AB
BR
EV
IA
TIO
NS
AC AIR CONDITIONING, ALTERNATING CURRENTACU AIR CONDITIONING UNITADD ADDENDUMADDN ADDITIONAFF ABOVE FINISH FLOORAHU AIR HANDLING UNITALT ALTERNATEAMP AMPEREAPPROX APPROXIMATE (LY)ARCH ARCHITECT (URAL)AUD AUDITORIUMAUTO AUTOMATICAV ACID VENTAVE AVERAGE
B BOILER, BRICK, BOTTOMBCU BLOWER COIL UNITBOT BOTTOMBP BY-PASSBTU BRITISH THERMAL UNITSBTUH BRITISH THERMAL UNITS PER HOUR
C CONDUITCATV CABLE TELEVISIONCB CIRCUIT BREAKERCCTV CLOSED CIRCUIT TELEVISIONCFM CUBIC FEET PER MINUTECFMF COLD FORMED METAL FRAMING
CHUV CEILING HUNG UNIT VENTILATORCLG CEILINGCLRM CLASSROOMCOL COLUMNCOMB COMBINATIONCOMP COMPRESS (ED) (ION) (IBLE)CONN CONNECTIONCONST CONSTRUCTIONCONT CONTINOUSCONTR CONTRACT (OR)COORD COORDINATECORR CORRIDORCR CEILING REGISTERCT CURRENT TRANSFORMERCTR CENTERCU CONDENSING UNITCUH CABINET UNIT HEATERCV CONVECTOR
D DEPTH
DC DIRECT CURRENTDDC DIRECT DIGITAL CONTROLDEG DEGREESDEMO DEMOLISHDIA DIAMETERDIAG DIAGONALDIM DIMENSIONDIST DISTANCEDIV DIVISIONDN DOWNDWG DRAWING
DTL DETAILDS DOOR INTRUSION SWITCH
E EASTEA EACHEC ELECTRICAL CONTRACTOREF EXHAUST FANELEC ELECTRIC (AL)ELEV ELEVATIONEM EMERGENCYEMT ELECTRICAL METALLIC TUBINGENCL ENCLOSUREEQ EQUAL, EQUIVALENTEQUIP EQUIPMENT
EWC ELECTRIC WATER COOLEREX EXISTINGEXH EXHAUSTEXT EXTERIOR, EXTERNAL
ABBREVIATIONS
EUH ELECTRIC UNIT HEATER
CH COUNTER HEIGHT
F FAHRENHEITFA FIRE ALARMFCU FAN COOLING UNITFF FINISH FLOORFIXT FIXTUREFL FLUSHFLEX FLEXIBLEFLR FLOORFLUOR FLUORESCENTFM FLOOR MOUNTEDFMC FLEXIBLE METAL CONDUITFP FIREPROOF (ING)FPM FEET PER MINUTEFS FLOW SWITCHFT FEETFTG FOOTING
GALV GALVANIZEDGC GENERAL CONTRACT (OR)GFI GROUND FAULT INTERRUPTERGFCI GROUND FAULT CIRCUIT INTERUPTERG, GND GROUND
H HEIGHTHC HEATING CONTRACT (OR), HANDICAPHDW HARDWAREHORIZ HORIZONTALHP HORSEPOWER, HEAT PUMPHR HOUR
HT HEIGHTHSP HIGH SERVICE PUMP
HV HIGH VOLTAGEHVAC HEATING/VENTILATING/AIR CONDITIONINGHVU HEATING AND VENTILATING UNIT
IN INCHESINCL INCLUDE (D) (ING)INS INSULATE (D) (ION)INT INTERIORINV INVERT
JAN, JC JANITORS CLOSETJB JUNCTION BOXJCT JUNCTION
KW KILOWATTKWH KILOWATT PER HOURKV KILOVOLTKVA KILOVOLT AMPERE
L LENGTH, LONGLA LIGHTNING ARRESTORLAV LAVATORYLB POUNDLBL LABELLE LEVEL ELEMENTLF LINEAR FOOTLFMC LIQUID-TIGHT FLEXIBLE METAL CONDUITLFNC LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUITLG LENGTH, LONGLGI LARGE GROUP INSTRUCTIONLH LEFT HANDLIT LLEVEL INDICATING TRANSMITTERLKR LOCKERLP LIGHTING PANELLT LIGHTLV LOW VOLTAGELTG LIGHTING
MAN MANUALMAT MATERIALMAU MAKE UP AIR UNITMAX MAXIMUM
MD MOTORIZED DAMPERME MECHANICAL EQUIPMENTMECH MECHANICAL (LY)MED MEDIUMMEZZ MEZZANINEMFR MANUFACTURE (R)
MH MAN HOLEMIN MINIMUMMISC MISCELLANEOUSMOD MODULE (OR), MODEL
MTD MOUNTEDMTG MOUNTINGMTR METER
N NORTH, NEUTRALNC NORMALLY CLOSEDNEC NATIONAL ELECTRIC CODENEG NEGATIVENIC NOT IN CONTRACTNO NUMBER, NORMALLY OPENNOM NOMINALNTS NOT TO SCALE
OC ON CENTEROE OVERHEAD ELECTRICOPP OPPOSITEOPP HD OPPOSITE HAND
P POLEPART PARTITIONPC PHOTOCELLPERF PERFORATE (ION) (ED)PERI PERIMETERPERP PERPENDICULARPGB PPUMP GROUND BUSPM PLUGMOLDPNL PANELPOC POINT OF CONNECTION
PR PAIRPRE POWER ROOF EXHAUSTERPREP PREPARE (ATION)PROJ PROJECTPS POWER SUPPLYPSI POUNDS PER SQUARE INCHPT POINTPVC POLYVINYL CHLORIDEPVMT PAVEMENTPWE POWER WALL EXHAUSTER
R RADIUS, RETURNRAD RADIATIONRAF RETURN AIR FANRC ROOFING CONTRACT (OR)RCP REFLECTED CEILING PLANRCU REMOTE CONDENSING UNITRECEPT RECEPTACLEREF REFERENCEREFL REFLECT (ED) (IVE) (OR)REFR REFRIGERATORREG REGISTERREINF REINFORCE (D) (ING)REM REMOVEDREQD REQUIREDRET RETURNREV REVISION, REVISEDRGS RIGID GALVANIZED STEELRH RIGHT HANDRHC REHEAT COILRM ROOMRMC RIGID METAL CONDUITRNC RIGID NONMETALLIC CONDUITRPM REVOLUTIONS PER MINUTERTH ROOF TOP HOODRTU ROOF TOP UNIT
S SOUTH, SUPPLY, SURGE PROTECTEDSA SUPPLY AIRSAN SANITARYSCHED SCHEDULESEC SECTIONSF SQUARE FEETSGI SMALL GROUP INSTRUCTIONSHT SHEETSIM SIMILARSP SPACE (ING) (ES)SPEC SPECIFICATION (S)SPD SURGE PROTECTION DEVICESQ SQUARESSSS SOLID STATE SOFT STARTERSTD STANDARDSTOR STORAGESTRU STRUCTURALSURF SURFACESV SOLENOID VALVESYM SYMMETRICALSYS SYSTEM
T THERMOSTATTB TACK BOARDTBD TO BE DETERMINEDTC TELECOMMUNICATIONS CONTRACTORTEL TELEPHONETEMP TEMPERATURE
TV TELEVISIONTYP TYPICAL
UC UNDERGROUND COMMUNICATIONSUE UNDERGROUND ELECTRICUG UNDERGROUNDUH UNIT HEATERUNO UNLESS NOTED OTHERWISEUT UNDERGROUND TELEPHONEUV UNIT VENTILATOR
V VOLTVAR VARIES, VARIABLEVAV VARIABLE AIR VOLUMEVERT VERTICALVEST VESTIBULEVFD VARIABLE FREQUENCY DRIVEVOL VOLUME
W WEST, WIDTH, WIDE, WATT, WALL HUNG, WIRE
WM WIREMOLDWP WATER PROOFWR WATER REPELLENT, WALL REGISTERWT WEIGHTWWHP WATER TO WATER HEAT PUMPW/ WITHW/O WITHOUT
SYMBOLSL
&
@
DEGREE
DIAMETER
AT
AND
ANGLE
A AMP
DB DUCT BANK
IP INSTRUMENT PANEL
MCP MAIN CONTROL PANELMCC MOTOR CONTROL CENTER
MGB MAIN GROUND BUS
MPR MOTOR PROTECTION RELAYMSH MOTOR SPACE HEATER
PP POWER PANEL
TS TAMPER SWITCHTGB TELEPHONE GROUND BUS
WIT WEIGHT INSTRUMENT TRANSMITTERWE WEIGHT ELEMENT
-
FH
FH
x xx
x
x
x
x
xx
xx
xx
xx
xx
x
xxxxxxxxxx
xx
xx
xx
xx
xx
xx
x
x
x
x
x
x
x
x
x
x
xxx
xx
xx
xx
xx
x
x x x
x
x xx
xx x x
xx
xx
x
x
x
x
x
x
x
x
x
x
x
xxxxxxxxx
x
DB
H
D
H
D
H
D
DB
DB DB DB DB DB DB DB DB DB DB DB DB DB DB DB DB
DB
0301
AIT
0301
AE
JB
0302
AIT
0302
AE
0306
AIT
0306
AE
0307
AIT
0307
AE
x
x
x
DB DB DB DB DB DB DB DB DB DB
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:1
5:3
1 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-101
OV
ER
ALL
SIT
E E
LE
CT
RIC
AL P
LA
N
E-102
E-103
E-104
E-105
E-106
0
SCALE:
75' 150' 300'
1" = 150'
N
E-107
MA
TC
H L
IN
E "A
"
E-211
MA
TC
H L
IN
E "A
"
SEE AVALON ROAD GATE
ENLARGED PLAN ON SHEET
E-211.
TREATMENT BUILDING
WATER SUPPLY
FACILITY MAIN
GATE
WATER
CONSERV II
MAIN GATE
OVERHEAD
UTILITY LINES BY
DUKE ENERGY
GST NO. 1
GST NO. 2
WELL NO. 4
WELL NO. 3
WELL NO. 2
WELL NO. 5
WELL NO. 6WELL NO. 1
CONNECTION TO
EXISTING DUKE ENERGY
UTILITY LINES.
SR
5
45
A
VA
LO
N R
OA
D
NOTES:
1. SEE CIVIL DRAWINGS FOR ADDITIONAL SITE
INFORMATION.
2. REMOVE EXISTING PULL BOX. PROVIDE NEW PULL
BOX (MATCH EXISTING SIZE) WITH H-20 RATED
TRAFFIC COVER. PULL BOX DEPTH SHALL BE
DETERMINED IN FIELD. PULL BOX SHALL HAVE OPEN
BOTTOM. COORDINATE WITH OWNER AND WCII A
MINIMUM OF 48 HOURS IN ADVANCE OF ANY WORK.
3. PROVIDE PULL BOX SEE DETAIL 32/E-505.
SEE NOTE 2
SEE NOTE 2
SEE NOTE 2
SEE NOTE 2
SEE NOTE 2
SEE NOTE 2
SEE NOTE 2
SEE NOTE 3
SEE NOTE 3SEE NOTE 3SEE NOTE 3
SEE NOTE 3SEE NOTE 3
TELEPHONE PEDESTAL,
CONTRACTOR SHALL COORDINATE
WITH TELEPHONE COMPANY
2-2" C WITH PULL
STRING FOR
FIBER SERVICE.
A
E-101
4'-0" MIN.
1'-0" MIN.
UNDERGROUND
DUCT SECTIONA
E-101
SCALE: NTS
OVERHEAD
UTILITY LINES BY
DUKE ENERGY
54" EXISTING
MAIN
COUNTY RD 388
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
6/2
01
7 9
:3
6:4
1 A
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-102
SIT
E E
LE
CT
RIC
AL P
LA
N
0
SCALE:
15' 30' 60'
1" = 30'
N
MATCH LINE - SEE SHEET E-103 FOR CONTINUATION
MATCH LINE - SEE SHEET E-107 FOR CONTINUATION
NOTES:
1. LIGHT POLES SHOWN ON THIS DRAWING SHALL
NOT HAVE PHOTOCELL.
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:1
7:5
0 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-103
SIT
E E
LE
CT
RIC
AL P
LA
N
0
SCALE:
15' 30' 60'
1" = 30'
N
MATCH LINE - SEE SHEET E-102 FOR CONTINUATION
MA
TC
H L
IN
E - S
EE
S
HE
ET
E
-104 F
OR
C
ON
TIN
UA
TIO
N
NOTES:
1. LIGHT POLES SHOWN ON THIS DRAWING SHALL
NOT HAVE PHOTOCELL.
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:1
8:5
1 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-104
SIT
E E
LE
CT
RIC
AL P
LA
N
0
SCALE:
15' 30' 60'
1" = 30'
N
MATCH LINE - SEE SHEET E-105 FOR CONTINUATION
MA
TC
H L
IN
E - S
EE
S
HE
ET
E
-103 F
OR
C
ON
TIN
UA
TIO
N
NOTES:
1. FOR WELL LOCATIONS REFER TO CIVIL AND
PROCESS SHEETS.
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:2
0:0
8 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-105
SIT
E E
LE
CT
RIC
AL P
LA
N
0
SCALE:
15' 30' 60'
1" = 30'
N
MATCH LINE - SEE SHEET E-104 FOR CONTINUATION
MATCH LINE - SEE SHEET E-106 FOR CONTINUATION
NOTES:
1. FOR WELL LOCATIONS REFER TO CIVIL AND
PROCESS SHEETS.
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:2
1:2
2 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-106
SIT
E E
LE
CT
RIC
AL P
LA
N
0
SCALE:
15' 30' 60'
1" = 30'
N
MATCH LINE - SEE SHEET E-105 FOR CONTINUATION
NOTES:
1. FOR WELL LOCATIONS REFER TO CIVIL AND
PROCESS SHEETS.
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:2
2:1
7 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
01
E
LE
CT
RIC
AL
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-107
SIT
E E
LE
CT
RIC
AL P
LA
N
0
SCALE:
15' 30' 60'
1" = 30'
N
MATCH LINE - SEE SHEET E-102 FOR CONTINUATION
-
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:2
3:0
4 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
08
D
UC
T B
AN
K S
EC
TIO
NS
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
E-108
DU
CT
B
AN
K S
EC
TIO
NS
NOTES:
1. ALL CONDUITS (POWER AND CONTROLS) BELOW
GRADES SHALL BE CONCRETE ENCASED WITH RED
DYED CONCRETE. DUCT BANKS SHALL BE INSTALLED
PER LOW AND MEDIUM VOLTAGE DUCT SECTIONS
DETAILS ON SHEETS E-503, AND E-507.
A
E-102
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
3. 1 1/4"C(4#3, 1#3)
4. 1"C(2#8, 1#8)
5. 1"C(2#8, 1#8)
6. 1"C(2#8, 1#8)
7. 1"C(4#8, 1#8)
POWER SPARES:
8. 4"C(PULL-STRING)
9. 2"C(4 SP, PULL-STRING)
10. 1"C(8 SP, PULL STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
3. 1"C(4#14)
4. 1"C(4#14)
5. 1"C(2/C#16SH)
6. 1"C(2/C#16SH)
7. 1-1/2"C(10-2/C#16SH)
8. 1"C(8#14)
COMMUNICATIONS SPARES:
9. 2"C(3 SP, PULL-STRING)
10. 1"C(8 SP, PULL-STRING)
1. PMS-4 TO SWGR-1
2. SWGR-1 TO WELL NO. 2
3. RECEPTACLES TO PANEL LP-33,41
4. LIGHT POLES TO PANEL PP-12,14
5. LE/LIT-0101 TO PANEL IP-9
6. LE/LIT-0102 TO PANEL IP-11
7. AE/AIT-0301,0302,0306,0307 TO PANEL IP-16,18
8. PMS-4 TO SWGR-1
9. JUNCTION BOX TO ELECTRICAL ROOM
10. JUNCTION BOX TO ELECTRICAL ROOM
1. WELL NO. 4 TO MCP
2. MCP TO WELL NO. 2
3. GROUND STORAGE TANK NO. 1 TO MCP
4. GROUND STORAGE TANK NO. 2 TO MCP
5. GROUND STORAGE TANK NO. 1 TO MCP
6. GROUND STORAGE TANK NO. 2 TO MCP
7. AE/AIT-0301,0302,0306,0307 TO MCP
8. AE/AIT-0301,0302,0306,0307 TO MCP
9. JUNCTION BOX TO ELECTRICAL ROOM
10. JUNCTION BOX TO ELECTRICAL ROOM
C
E-103
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANKCOMMUNICATIONS DUCTBANK
9
3 4
9 9 9
10 10 10 10
10 10 10 10
6
2 3 4 5
7 8 9 9
10 10 10 10 9
10 10
J
E-102
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER DUCTBANK
1
POWER:
1. 1"C(2#8, 1#8)
POWER SPARES:
2. 1"C(2 SP, PULL-STRING)
1. LIGHT POLES TO PANEL PP-8,10
2. ELECTRICAL ROOM TO JUNCTION BOX
2 2
E
E-103
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANK COMMUNICATIONS DUCTBANK
1
POWER:
1. 1 1/4"C(4#3, 1#3)
2. 1"C(2#8, 1#8)
3. 1"C(2#8, 1#8)
4. 1"C(2#8, 1#8)
5. 1"C(4#8, 1#8)
POWER SPARES:
6. 2"C(PULL-STRING)
7. 1"C(2SP, PULL-STRING)
COMMUNICATIONS:
1. 1"C(4#14)
2. 1"C(4#14)
3. 1"C(2/C#16SH)
4. 1"C(2/C#16SH)
5. 1-1/2"C(10-2/C#16SH)
COMMUNICATIONS SPARES:
6. 2"C(PULL-STRING)
7. 1"C(2 SP, PULL-STRING)
1. RECEPTACLES TO PANEL LP-33, 41
2. LIGHT POLES TO PANEL PP-12, 14
3. LE/LIT-0101 TO PANEL IP-9
4. LE/LIT-0102 TO PANEL IP-11
5. AE/AIT-0301,0302,0306,0307 TO IP-16,18
6. JUNCTION BOX TO JUNCTION BOX
7. JUNCTION BOX TO JUNCTION BOX
1. GROUND STORAGE TANK NO. 1 TO MCP
2. GROUND STORAGE TANK NO. 2 TO MCP
3. GROUND STORAGE TANK NO. 1 TO MCP
4. GROUND STORAGE TANK NO. 2 TO MCP
5. AE/AIT-0301,0302,0306,0307 TO MCP
6. JUNCTION BOX TO JUNCTION BOX
7. JUNCTION BOX TO JUNCTION BOX
1 2 31 22 3
5 6 7
4 1 2 31 22 3
6 7 7
4
D
E-103
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
3
POWER
DUCTBANK
COMMUNICATIONS DUCTBANK
1 2
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
3. 1"C(2#8, 1#8)
POWER SPARES:
4. 4"C(PULL-STRING)
5. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(2 SP, PULL-STRING)
1. PMS-4 TO SWGR-1
2. SWGR-1 TO WELL NO. 2
3. LIGHT POLES TO PANEL PP-12,14
4. PMS-4 TO SWGR-1
5. PMS-4 TO SWGR-1
1. WELL NO. 4 TO MCP
2. MCP TO WELL NO. 2
3. JUNCTION BOX TO JUNCTION BOX
2
3 3
7
10
1 2
8 8
5 6
5kv DUCTBANK
1
POWER DUCTBANKCOMMUNICATIONS DUCTBANK
9
3 4
9 9 9
10 10 10 10
10 10 10 10
6
2 3 4 5
7 8 9 9
10 10 10 10 9
10 10 10
1 2
8 8
5 6
5kv DUCTBANK
7
7
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
3. 1 1/4"C(4#3, 1#3)
4. 1"C(2#8, 1#8)
5. 1"C(2#8, 1#8)
6. 1"C(2#8, 1#8)
7. 1"C(4#8, 1#8)
POWER SPARES:
8. 4"C(PULL-STRING)
9. 2"C(4 SP, PULL-STRING)
10. 1"C(8 SP, PULL STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
3. 1"C(4#14)
4. 1"C(4#14)
5. 1"C(2/C#16SH)
6. 1"C(2/C#16SH)
7. 1-1/2"C(10-2/C#16SH)
8. 1"C(8#14)
COMMUNICATIONS SPARES:
9. 2"C(3 SP, PULL-STRING)
10. 1"C(8 SP, PULL-STRING)
1. PMS-4 TO SWGR-1
2. SWGR-1 TO WELL NO. 2
3. RECEPTACLES TO PANEL LP-33,41
4. LIGHT POLES TO PANEL PP-12,14
5. LE/LIT-0101 TO PANEL IP-9
6. LE/LIT-0102 TO PANEL IP-11
7. AE/AIT-0301,0302,0306,0307 TO PANEL IP-14,16
8. PMS-4 TO SWGR-1
9. JUNCTION BOX TO ELECTRICAL ROOM
10. JUNCTION BOX TO ELECTRICAL ROOM
1. WELL NO. 4 TO MCP
2. MCP TO WELL NO. 2
3. GROUND STORAGE TANK NO. 1 TO MCP
4. GROUND STORAGE TANK NO. 2 TO MCP
5. GROUND STORAGE TANK NO. 1 TO MCP
6. GROUND STORAGE TANK NO. 2 TO MCP
7. AE/AIT-0301,0302,0306,0307 TO MCP
8. AE/AIT-0301,0302,0306,0307 TO MCP
9. JUNCTION BOX TO ELECTRICAL ROOM
10. JUNCTION BOX TO ELECTRICAL ROOM
5
1 2
4 5
10
10
M
E-105
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
4. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-3 TO PMS-2
2. PMS-3 TO PMS-2
3. JUNCTION BOX TO JUNCTION BOX
4. JUNCTION BOX TO JUNCTION BOX
1. WELL NO. 3 TO WELL NO. 2
2. WELL NO. 1 TO MCP
3. JUNCTION BOX TO JUNCTION BOX
1 21 2
3 3
1
3
2
4
COMMUNICATIONS DUCTBANK5kv DUCTBANK
K
E-104
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
4. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-1 TO PMS-5
2. PMS-5 TO PMS-1
3. PMS-5 TO PMS-3
4. PMS-5 TO PMS-3
1. WELL NO. 2 TO WELL NO. 6
2. WELL NO. 5 TO WELL NO. 1
3. JUNCTION BOX TO JUNCTION BOX
1 21 2
3 3
1
3
2
4
COMMUNICATIONS DUCTBANK5kv DUCTBANK
N
E-105
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
COMMUNICATIONS DUCTBANK
1 2
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-2 TO WELL NO. 2
2. PMS-2 TO WELL NO. 2
3. JUNCTION BOX TO WELL NO. 2
1. WELL NO. 3 TO WELL NO. 2
2. WELL NO. 2 TO WELL NO. 6
3. WELL NO. 2 TO JUNCTION BOX
3 3
2
3
5kv DUCTBANK
1
L
E-104
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-3 TO WELL NO. 3
2. WELL NO. 3 TO PMS-3
3. JUNCTION BOX TO WELL NO. 3
1. WELL NO. 3 TO WELL NO. 2
2. WELL NO. 4 TO WELL NO. 3
3. WELL NO. 3 TO JUNCTION BOX
COMMUNICATIONS DUCTBANK
1 2
3 3
2
3
5kv DUCTBANK
1
F
E-104
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1 2
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
4. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(2 SP, PULL-STRING)
1. PMS-4 TO PMS-3
2. PMS-4 TO PMS-3
3. JUNCTION BOX TO JUNCTION BOX
4. JUNCTION BOX TO JUNCTION BOX
1. WELL NO. 4 TO WELL NO. 3
2. WELL NO. 1 TO MCP
3. PMS-4 TO PMS-3
1 2
3 3
1
3
2
4
COMMUNICATIONS DUCTBANK5kv DUCTBANK
G
E-104
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
4. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(2 SP, PULL-STRING)
1. SWGR-1 TO PMS-4
2. SWGR-1 TO PMS-4
3. SWGR-1 TO PMS-4
4. SWGR-1 TO PMS-4
1. MCP TO WELL NO. 4
2. WELL NO. 1 TO MCP
3. PMS-4 TO JUNCTION BOX
1 21 2
3 3
1
3
2
4
COMMUNICATIONS DUCTBANK5kv DUCTBANK
H
E-104
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
COMMUNICATIONS DUCTBANK
1 2
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-4 TO WELL NO. 4
2. WELL NO. 4 TO PMS-4
3. WELL NO. 4 TO PMS-4
1. WELL NO. 4 TO WELL NO. 3
2. MCP TO WELL NO. 4
3. WELL NO. 4 TO PMS-4
3 3
2
3
5kv DUCTBANK
1
5kv DUCTBANK
-
E-109
DU
CT
B
AN
K S
EC
TIO
NS
ww
w.te
tra
te
ch
.co
m
MA
RK
DA
TE
DE
SC
RIP
TIO
NB
Y
11
/1
4/2
01
7 4
:2
3:4
3 P
M - \\T
TS
18
1F
S1
\P
RO
JE
CT
S\IE
R\1
00
34
\2
00
-1
00
34
-1
40
01
\C
AD
\S
HE
ET
FIL
ES
\E
-1
09
D
UC
T B
AN
K S
EC
TIO
NS
.D
WG
- C
HA
NC
EL
LO
R, W
YA
TT
1
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
Co
pyrig
ht: T
etra
T
ech
MA
LC
OLM
R
OA
D W
AT
ER
S
UP
PLY
F
AC
ILIT
Y
20
1 E
AS
T P
IN
E S
TR
EE
T, S
UIT
E 1
00
0
OR
LA
ND
O, F
LO
RID
A 3
28
01
PH
ON
E: 4
07
-8
39
-3
95
5 F
AX
: 4
07
-8
39
-3
79
0
BID SET
EN
GIN
EE
RIN
G B
US
IN
ES
S N
O. 2429
U
E-102
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANK COMMUNICATIONS DUCTBANK
1
POWER:
1. 2"(3#4, 1#4)
POWER SPARES:
2. 2"C(2 SP, PULL-STRING)
3. 1"C(2 SP, PULL-STRING)
COMMUNICATIONS:
1. 3"C(PULL-STRING)
2. 3"C(PULL-STRING)
3. 2"C(FIBER OPTIC)
4. 1"C(5#14, 1#14)
COMMUNICATIONS SPARES:
5. 2"C(2 SP, PULL-STRING)
6. 1"C(2 SP, PULL-STRING)
1. GATE JUNCTION BOX NO. 1 TO PANEL LP-28,30
2. ELECTRICAL ROOM TO FRONT GATE
3. ELECTRICAL ROOM TO FRONT GATE
1. COMMUNICATIONS HANDHOLE TO 4'X8' COMM
BACKBOARD IN CONTROL ROOM.
2. COMMUNICATIONS HANDHOLE TO 4'X8' COMM
BACKBOARD IN CONTROL ROOM.
3. GATE MAIN CONTROLLER TO GATE JUNCTION BOX NO. 1
4. MCP TO GATE JUNCTION BOX NO. 1
5. ELECTRICAL ROOM TO FRONT GATE
6. ELECTRICAL ROOM TO FRONT GATE
2 2
3 3
2 3
5 5 6
V
E-102
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANK
POWER:
1. 4"C(4#500kCMIL (5kV), 1#2/0)
POWER SPARES:
2. 4"C(PULL-STRING)
1. UTILITY TRANSFORMER TO SWGR-1
2. UTILITY TRANSFORMER TO SWGR-1
2
W
E-102
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANK (12.47V)
POWER:
1. 4"C(PULL-STRING)
POWER SPARE:
1. 4"C (PULL-STRING)
1. UTILITY TRANSFORMER TO UTILITY POLE
1. UTILITY TRANSFORMER TO UTILITY POLE
2
X
E-102
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
COMMUNICATIONS DUCTBANK
COMMUNICATIONS:
1. 3"C(PULL-STRING)
2. 3"C(PULL-STRING)
1. UTILITY COMMUNICATIONS HANDHOLE TO 4'X8' COMM BACKBOARD
IN CONTROL ROOM.
2. COMMUNICATIONS HANDHOLE TO 4'X8' COMM BACKBOARD IN
CONTROL ROOM.
2
4
Y
E-103
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANK COMMUNICATIONS DUCTBANK
1
POWER:
1. 1"C(2#12, 1#12)
2. 1"C(2#12, 1#12)
COMMUNICATIONS:
1. 1"C(4#14)
2. 1"C(2/C#16SH)
1. RECEPTACLES TO PANEL LP-33
2. LE/LIT-0101 TO PANEL IP-9
1. GROUND STORAGE TANK NO. 1 TO MCP
2. GROUND STORAGE TANK NO. 1 TO MCP
1 21 22 1 21 22
Z
E-103
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
1
POWER DUCTBANK COMMUNICATIONS DUCTBANK
1
POWER:
1. 1"C(2#12, 1#12)
2. 1"C(2#12, 1#12)
COMMUNICATIONS:
1. 1"C(4#14)
2. 1"C(2/C#16SH)
1. RECEPTACLES TO PANEL LP-41
2. LE/LIT-0101 TO PANEL IP-11
1. GROUND STORAGE TANK NO. 2 TO MCP
2. GROUND STORAGE TANK NO. 2 TO MCP
1 21 22 1 21 22
6
NOTES:
1. ALL CONDUITS (POWER AND CONTROLS) BELOW
GRADES SHALL BE CONCRETE ENCASED WITH RED
DYED CONCRETE. DUCT BANKS SHALL BE INSTALLED
PER LOW AND MEDIUM VOLTAGE DUCT SECTIONS
DETAILS ON SHEETS E-503, AND E-507.
T
E-106
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-1 TO PMS-6
2. PMS-6 TO PMS-1
3. PMS-1 TO PMS-6
1. WELL NO. 5 TO WELL NO. 1
2. WELL NO. 1 TO MCP
3. PMS-1 TO PMS-6
COMMUNICATIONS DUCTBANK
1 2
3 3
5kv DUCTBANK
2
3
1
R
E-106
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
4. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-2 TO PMS-1
2. PMS-1 TO PMS-2
3. PMS-2 TO WELL NO. 1
4. PMS-2 TO WELL NO. 1
1. WELL NO. 2 TO WELL NO. 6
2. WELL NO. 1 TO MCP
3. JUNCTION BOX TO JUNCTION BOX
1 21 2
3 3
1
3
2
4
COMMUNICATIONS DUCTBANK5kv DUCTBANK
O
E-105
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
COMMUNICATIONS DUCTBANK
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-5 TO WELL NO. 5
2. WELL NO.5 TO PMS-5
3. PMS-5 TO WELL NO. 5
1. WELL NO. 6 TO WELL NO. 5
2. WELL NO. 5 TO WELL NO. 1
3. WELL NO. 5 TO JUNCTION BOX
5kv DUCTBANK
1 2
3
2
3
1
Q
E-106
SECTION
DUCTBANK
SCALE: NTS (SEE NOTE 1)
POWER:
1. 4"C(3#4/0 (5kV), 1#2)
2. 4"C(3#4/0 (5kV), 1#2)
POWER SPARES:
3. 4"C(PULL-STRING)
COMMUNICATIONS:
1. 2"C(FIBER OPTIC)
2. 2"C(FIBER OPTIC)
COMMUNICATIONS SPARES:
3. 2"C(PULL-STRING)
1. PMS-5 TO WELL NO. 6
2. WELL NO.6 TO PMS-5
3. PMS-6 TO WELL NO. 6
1. WELL NO. 2 TO WELL NO. 6
2. WELL NO. 6 TO WELL NO. 5
3. WELL NO. 6 TO JUNCTION BOX
COMMUNICATIONS DUCTBANK
1 2
3 3
2
3
5kv DUCTBANK
1
3