dx condensing units for both cooling and heat pump

8
3 DX Condensing Units for both cooling and heat pump applications

Upload: others

Post on 18-May-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DX Condensing Units for both cooling and heat pump

3

DX Condensing Units for both cooling and heat pump applications

Page 2: DX Condensing Units for both cooling and heat pump

2

VES Andover offer a comprehensive range of condensing units for both cooling only and heat pump application, designed to match your VES air handling unit.

Both outdoor and plantroom units are available.

Duty range from 5.0kw to 431.0kw.

VES offer you a choice - from budget no frills units to high spec.super quiet units.

All have nationwide service back up.

Comprehensive technical and installation instructions provided for all units.

PRODUCT GUIDE

A SERIESSuper quiet running, sophisticated control functions and low running costs.Cooling only and heat pump option.Duty range 9.4kw to 94.7 kw.

C SERIESVertical indoor condensing units with centrifugal fanfor ducted discharge. Cooling only and heat pumpoption. Duty range 19.4kw to 111.6kw.

E SERIESHigh spec. units with dual compressors in tandemproviding up to six steps of control from only tworefrigerant circuits. Ultra quiet operation.Duty range 46.3kw to 431.0kw.

H SERIESBudget range of condensing and heat pump units.Duties from 5.2kw to 17.5kw.

ASERIES

CSERIES

ESERIES

HSERIES

For the air that we breatheFor the air that we breatheVES Andover LimitedEagle Close, Chandlers Ford Industrial Estate,Chandlers Ford, Eastleigh, Hampshire SO53 4NF

Tel: 08702 40 43 40Fax: 08702 40 45 50e-mail: [email protected]

VES reserve the right to amend productspecifications and details without notice.

© 2003 VES Andover Ltd. Leaflet No. 795-8/03ISO 9001-2000

Cert. No. Q5375

Page 3: DX Condensing Units for both cooling and heat pump

3

Standard Features

Optional Extras

Technical Details

Crankcase heater.

VECON Cooling Cooling Heating Supply No. No. of No. of Power Maximum MaximumModel capacity capacity capacity voltage of compressors/ capacity consumption current starting

kw kw kw circuits fans steps kw amps currentevap.5°C evap.8°C amps

H 18/C* 5.2 5.7 - 230v, 1 ph 1 1/1 1 1.8 9.7 48.9H 24/C* 7.1 8.0 - 230v, 1 ph 1 1/1 1 2.3 11.3 61.9H 36/C-1* 9.8 10.9 - 230v, 1 ph 1 1/1 1 3.4 16.4 98.9H 36/C-3 9.8 10.9 - 400v, 3 ph 1 1/1 1 3.6 7.0 47.0H 48/C 12.3 13.7 - 400v, 3 ph 1 1/1 1 4.8 9.8 66.1H 65/C 15.8 17.5 - 400v, 3 ph 1 1/1 1 5.9 9.8 76.1H 24/P* 7.1 8.0 4.6 230v, 3 ph 1 1/1 1 2.3 11.3 61.9H 36/P-1* 9.8 10.9 7.0 230v, 1 ph 1 1/1 1 3.4 16.4 98.9H 36/P-3 9.8 10.9 7.0 400v, 3 ph 1 1/1 1 3.6 7.0 47.0H 48/P 12.3 13.7 8.7 400v, 3 ph 1 1/1 1 4.8 9.8 66.1H 65/P 15.8 17.5 11.7 400v, 3 ph 1 1/1 1 5.9 9.8 76.1

Dimensions

VECON Model Height W x L Weight(mm) (mm) (kgs)

H 18/C, H24/C, H24/P 635 616 67H 36/C, H 36/P 838 616 75H 48/C, H48/P 838 616 89H 65/C, H 65/P 946 718 96

Sound LevelsPWL, dB, re 10-12 watts

VECON dBA dBA 63 125 250 500 1000 2000 4000 8000 Model @ 3 metres @ 10 metres Hz Hz Hz Hz Hz Hz Hz Hz

H 18/C 53 43 70 68 69 68 67 67 60 56H 24/C 53 43 71 69 68 67 68 67 60 58H 36/C 56 46 70 68 72 69 71 66 61 62H 48/C 60 50 82 80 76 78 73 71 66 61H 65/C 61 51 82 80 76 76 74 73 69 65H 24/P 53 43 71 69 68 67 68 67 60 58H 36/P 56 46 70 68 72 69 71 66 61 62H 48/P 60 50 82 80 76 78 73 71 66 61H 65/P 61 51 82 80 76 76 74 73 69 65

C units - cooling only, P units - heat pump.Cooling capacity based on evaporating at +5°C or +8°C with ambient temperature of 30°C.* Units supply voltage 230V, 1 Ph, 50Hz, otherwise 400V. 3 Ph, 50Hz.All condenser fans 230V, 1 Ph, 50Hz.

Budget range 5.0 - 17.5 kw.

Cooling only and heat pump options.

R407C refrigerant.

Hermetic scroll compressors in all models.

Filter dryer.

HP/LP switch protection.

All units: 1 refrigerant circuit,1 compressor, 1 fan.

Galvanised steel case with powder coatpaint finish, colour beige.

BS, CE and PED compliant.

51Air inlet to all sides

PLAN VIEWSIDE VIEW

HSERIES

Condensing

Units

W x L

Height

© 2003 VES Andover Ltd.

Page 4: DX Condensing Units for both cooling and heat pump

4

ASERIES

Condensing

Units

Standard Features Optional Extras

On/off condenser head pressure control (low ambient kit) includes crank case heater

Proportional condenser head pressure control(low ambient kit) includes crank case heater

Mains switch (only on models 24E to 86D)

Phase sequence protection

Soft starter (reducing peak compressor startingcurrent by 40%)

Hot gas bypass valve (only on models 24E to 86D)

Condenser coil protection grille (Note: standard on models 10E to 22E)

Coil fin anti-corrosion protection (for aggressive environments)

Anti vibration mounts (rubber)

Low noise kit (comprising of compressor acousticjacket and proportional head pressure control)

Service valves (10E - 22E with flared connections,24E to 86D with welded connections)

R407C refrigerant pre-charged at factory (includesservice valves) but does not allow for systemcharge of refrigerant (for connection lines)

Low noise, high specification duty range 9.4 to 94.7kW

Cooling only and heat pump option

R407C refrigerant

Galvanised and painted to RAL 9010

Hermetic scroll compressors

Quiet operation

HP/LP protection

Common fault indication

Remote on/off

Performance DataVECON Cooling Cooling Heating No. of No. of No. of Power Maximum MaximumModel* capacity capacity capacity circuits compressors capacity consumption current starting

kw when kw when kw /fans steps kw amps currentevap. 5°C evap. 8°C amps

A10E 9.4 10.6 - 1 1/1 1 2.7 9.7 46.0A12E 11.9 13.5 - 1 1/2 1 3.2 12.5 50.0A16E 14.1 15.9 - 1 1/2 1 4.2 15.4 66.0A18E 16.9 19.0 - 1 1/2 1 4.8 18.4 74.0A22E 18.5 20.9 - 1 1/2 1 5.7 20.7 101.0A24E 21.0 23.7 19.2 1 1/2 1 5.9 15.6 100.6A32E 29.2 32.9 25.8 1 1/1 1 8.8 24.5 130.5A38E 36.1 40.7 31.7 1 1/1 1 10.8 29.1 161.5A43E 41.0 46.0 37.0 1 1/1 1 13.5 33.5 192.5A48D 41.6 47.0 38.4 2 2/2 2 12.7 34.0 119.0A64D 58.3 65.8 51.7 2 2/2 2 17.6 49.0 155.0A76D 72.1 81.4 63.4 2 2/2 2 21.6 58.2 190.6A86D 84.0 94.7 74.0 2 2/2 2 25.9 67.0 226.0

*Model no’s: add suffix ‘C’ for cooling only or ‘P’ for heat pump operation.Cooling capacity based on evaporating at +5°C or +8°C with ambient temperature of 30°C.Heating capacity kw when ambient 0°C.All units supply voltage 400 volt 3 phase 50Hz, plus neutral.All condensing units are supplied with a nitrogen holding charge as standard.

Page 5: DX Condensing Units for both cooling and heat pump

5

ASERIES

Condensing

Units

VECON Length Height Depth Weight Liquid line connection Suction line connectionModel mm mm mm kg size (inches) size (inches)

A10E 973 931 333 73 ³⁄₈ ³⁄₄

A12E 973 1235 333 99 ³⁄₈ ³⁄₄

A16E 973 1235 333 109 ³⁄₈ ³⁄₄

A18E 973 1235 386 130 ¹⁄₂ ⁷⁄₈

A22E 973 1235 386 131 ¹⁄₂ ⁷⁄₈

A24E 1195 1375 660 225 ⁵⁄₈ 1¹⁄₈

A32E 980 1375 1195 250 ⁵⁄₈ 1¹⁄₈

A38E 980 1375 1195 270 ³⁄₄ 1³⁄₈

A43E 980 1375 1195 300 ⁷⁄₈ 1⁵⁄₈

A48D 1960 1375 1195 485 2 x ⁵⁄₈ 2 x 1¹⁄₈

A64D 1960 1375 1195 490 2 x ⁵⁄₈ 2 x 1¹⁄₈

A76D 1960 1375 1195 530 2 x ³⁄₄ 2 x 1³⁄₈

A86D 1960 1375 1195 590 2 x ⁷⁄₈ 2 x 1⁵⁄₈

Dimensions & Weights

Noise DataVECON Sound power spectrum PWL dB(A) weighted Sound SoundModel 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz pressure pressure

3m dB(A) 10m dB(A)

A10E Standard 68.0 69.4 67.7 66.9 65.8 64.0 62.4 52.0 53 43With low noise kit 59.0 61.2 61.0 61.9 60.8 61.7 54.4 50.0 49 39

A12E Standard 71.0 72.4 70.7 70.1 69.3 66.9 65.0 55.0 56 46With low noise kit 61.0 62.5 64.2 65.5 65.3 63.4 58.2 53.0 52 42

A16E Standard 71.0 72.4 70.7 70.2 69.9 67.5 64.5 55.0 57 47With low noise kit 61.0 62.6 64.1 66.6 66.3 63.7 58.7 53.0 52 42

A18E Standard 71.0 72.4 70.7 70.2 69.8 68.4 65.2 58.0 57 47With low noise kit 62.0 62.8 63.4 65.8 65.5 63.3 59.8 53.0 52 42

A22E Standard 71.0 72.4 70.7 70.2 70.5 69.5 66.6 58.0 58 48With low noise kit 62.0 65.4 65.9 65.6 65.9 65.2 62.5 54.0 53 43

A24E Standard 77.6 64.8 61.2 70.4 68.8 70.5 66.3 58.5 57 47With low noise kit 65.0 59.0 60.0 67.4 64.4 65.6 62.0 55.0 53 43

A32E Standard 78.1 78.7 70.8 72.8 76.5 75.7 67.7 62.4 63 53With low noise kit 71.0 70.0 65.0 68.5 69.0 68.7 61.9 54.0 56 46

A38E Standard 78.1 78.5 70.6 73.6 75.6 76.5 71.6 62.5 63 53With low noise kit 73.0 70.0 65.0 67.2 68.0 70.3 65.8 54.7 57 47

A43E Standard 78.1 78.6 70.8 75.9 76.6 78.9 71.6 62.8 65 55With low noise kit 74.0 72.0 65.0 70.9 70.0 72.4 64.9 55.0 58 48

A48D Standard 84.7 71.9 67.9 74.1 72.5 73.8 69.5 57.0 61 51With low noise kit 68.0 62.0 63.0 70.4 67.4 68.6 65.0 55.0 56 46

A64D Standard 81.1 81.7 73.8 73.8 79.5 78.7 70.7 65.4 66 56With low noise kit 74.0 73.0 68.0 68.0 72.0 71.7 64.9 57.0 59 49

A76D Standard 81.1 81.5 73.6 76.6 78.6 79.5 74.6 65.5 66 56With low noise kit 76.0 73.0 68.0 70.2 71.0 73.3 68.8 57.7 60 50

A86D Standard 81.1 81.6 73.8 78.9 79.6 81.9 74.6 65.8 68 58With low noise kit 77.0 75.0 68.0 73.9 73.0 75.4 67.9 58.0 61 51

A48D condenser with low noise kitfitted to compressors.

© 2003 VES Andover Ltd.

Page 6: DX Condensing Units for both cooling and heat pump

6

Standard Features Optional Extras

Performance Data

Condenser coil fin protection treatment- Alucoat Epoxy coating

HP/LP liquid filled gauges

Electronic soft starters

IP55 control panel

Anti vibration mounts: spring or rubber

Removable core filter drier

Compressor acoustic enclosure withaccess panels

Compressor suction valve

Compressor discharge valve

In line sight glass

Multi unit controller - digital display tocontrol up to 8 units

Crank case heaters

Door interlocked main on/off switch

Condenser coil protection grille

VECON Cooling Cooling Power Power Maximum Maximum No. of No. of No. ofModel capacity capacity consumption consumption current starting circuits compressors capacity

kw kw kw when kw when amps current /fans stepsevap. 5°C evap. 8°C evap. 5°C evap. 8°C amps

E040SLN 46.3 50.5 11.9 12.2 32 120 1 2/2 2E045SLN 53.2 57.9 14.5 14.9 40 145 1 2/2 2E065SLN 73.4 79.7 21.8 22.6 53 185 1 2/2 2E075SLN 84.5 91.7 25.9 26.9 63 215 1 2/2 2E100STD 103.0 111.0 39.8 41.3 80 120 1 3/2 3E100LN 109.0 118.0 36.5 37.6 80 220 1 3/2 3E100SLN 110.0 120.0 33.3 34.4 78 210 1 3/3 3E110STD 114.0 123.0 49.2 51.3 97 255 1 3/2 3E110LN 123.0 133.0 44.4 46.0 96 255 1 3/2 3E110SLN 127.0 138.0 39.5 40.9 93 245 1 3/3 3E090DSTD 101.0 109.0 34.9 36.0 80 195 2 4/2 4E090DLN 102.0 111.0 34.3 35.4 80 195 2 4/2 4E090DSLN 106.0 116.0 29.7 30.5 90 90 2 4/4 4E130DSTD 139.0 150.0 52.6 54.5 109 250 2 4/3 4E130DLN 140.0 159.0 52.1 45.8 108 250 2 4/3 4E130DSLN 147.0 159.0 44.3 45.8 103 235 2 4/4 4E150DSTD 155.0 167.0 64.7 67.3 129 290 2 4/3 4E150DLN 166.0 181.0 58.1 91.3 128 290 2 4/3 4E150DSLN 169.0 183.0 52.5 54.3 123 275 2 4/4 4E200DSTD 210.0 227.0 85.8 89.2 169 360 2 4/4 4E200DLN 223.0 242.0 78.3 80.8 168 360 2 4/4 4E200DSLN 220.0 239.0 66.4 68.6 154 285 2 6/6 6E230DSTD 258.0 279.0 108.0 112.0 204 440 2 4/4 4E230DLN 270.0 292.0 101.0 105.0 203 440 2 4/4 4E230DSLN 254.0 276.0 79.1 81.9 184 335 2 6/6 6E300DSTD 312.0 337.0 130.0 135.0 250 445 2 6/6 6E300DLN 333.0 362.0 118.0 122.0 250 440 2 6/6 6E300DSLN 329.0 357.0 120.0 124.0 241 420 2 6/8 6E370DSTD 387.0 418.0 162.0 169.0 304 540 2 6/6 6E370DLN 405.0 438.0 152.0 158.0 303 540 2 6/6 6E370DSLN 398.0 431.0 155.0 161.0 293 520 2 6/8 6

Cooling capacity based on evaporating at +5°C or +8°C with ambient temperature of 30°C.All units supply voltage 400V, 3 Ph, 50Hz, plus neutral.Separate 230V, 1 Ph, 50Hz supply required to energise crank case heaters.

Low noise, high specification condensing units

Standard, low noise and super low noise options

R407C refrigerant

Galvanised and fully painted to RAL 9010

Hermetic scroll compressors

Unique design providing up to six steps of control with 2 refrigerant circuits

User friendly microprocessor control -STD/LN models

User friendly microprocessor control with digital display - SLN models (option on STD/LN models)

ESERIES

Condensing

Units

HP/LP protection

Duty sharing compressors ensureslonger life

Compressor anti-cycling protection

Volt free contact forremote failure indication

Lifting eyes for simpleplant handling

Page 7: DX Condensing Units for both cooling and heat pump

7

Noise Data

VECON Sound power spectrum PWL per octave band dB(A) Sound pressure Sound pressureModel 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 3m dB(A) 10m dB(A)

E040SLN 49 62 69 74 71 66 57 46 57 47E045SLN 49 62 69 74 71 68 61 46 58 48E065SLN 49 62 69 75 72 68 63 46 58 48E075SLN 49 62 69 74 72 69 64 46 58 48E100STD 47 69 75 84 88 87 85 72 75 65E100LN 46 67 72 79 83 83 78 67 70 60E100SLN 51 64 70 76 74 70 65 48 60 50E110STD 47 69 75 83 88 87 85 72 74 64E110LN 47 67 72 79 83 83 79 67 70 60E110SLN 51 64 70 76 74 71 66 48 60 50E090DSTD 52 69 75 83 87 87 85 72 74 64E090DLN 51 67 72 78 83 83 78 67 70 60E090DSLN 52 65 72 77 74 71 64 49 61 51E130DSTD 48 71 77 85 89 89 86 74 76 66E130DLN 48 68 73 81 85 85 80 69 72 62E130DSLN 52 65 72 78 75 71 66 49 61 51E150DSTD 49 71 77 85 90 89 87 74 76 66E150DLN 48 68 74 80 85 85 80 69 72 62E150DSLN 52 65 72 77 75 72 67 49 61 51E200DSTD 53 72 78 87 91 90 88 75 78 68E200DLN 53 70 75 83 86 86 82 70 73 63E200DSLN 54 67 73 79 77 73 68 51 63 53E230DSTD 51 72 78 88 91 90 88 75 78 68E230DLN 50 70 75 84 86 86 82 70 73 63E230DSLN 54 67 73 79 77 74 69 51 63 53E300DSTD 55 74 80 89 93 92 90 77 80 70E300DLN 55 71 77 85 88 88 83 72 75 65E300DSLN 55 68 75 81 79 75 72 52 65 55E370DSTD 52 74 80 90 93 92 90 77 80 70E370DLN 52 71 77 86 88 88 83 72 75 65E370DSLN 55 68 75 81 79 75 71 52 65 55

ESERIES

Condensing

Units

VECON Length Height Depth Weight Liquid line connection Suction line connectionModel mm mm mm kg size (inches) size (inches)

E040SLN 3304 1940 1054 843 ⁷⁄₈ 1⁵⁄₈E045SLN 3304 1940 1054 867 ⁷⁄₈ 1⁵⁄₈E065SLN 3304 1940 1054 915 ⁷⁄₈ 2¹⁄₈E075SLN 3304 1940 1054 968 ⁷⁄₈ 2¹⁄₈E100STD 3304 1912 1054 876 1¹⁄₈ 2¹⁄₈E100LN 3304 1940 1054 917 1¹⁄₈ 2¹⁄₈E100SLN 4704 1940 1054 1206 1¹⁄₈ 2¹⁄₈E110STD 3304 1912 1054 909 1¹⁄₈ 2¹⁄₈E110LN 3304 1940 1054 948 1¹⁄₈ 2¹⁄₈E110SLN 4704 1940 1054 1272 1¹⁄₈ 2¹⁄₈E090DSTD 4704 1912 1054 1142 2 x ⁷⁄₈ 2 x 1⁵⁄₈E090DLN 4704 1940 1054 1159 2 x ⁷⁄₈ 2 x 1⁵⁄₈E090DSLN 3304 1962 1904 1426 2 x ⁷⁄₈ 2 x 1⁵⁄₈E130DSTD 4704 1912 1054 1217 2 x ⁷⁄₈ 2 x 2¹⁄₈E130DLN 4704 1940 1054 1236 2 x ⁷⁄₈ 2 x 2¹⁄₈E130DSLN 3304 1962 1904 1538 2 x ⁷⁄₈ 2 x 2¹⁄₈E150DSTD 4704 1912 1054 1258 2 x ⁷⁄₈ 2 x 2¹⁄₈E150DLN 4704 1940 1054 1311 2 x ⁷⁄₈ 2 x 2¹⁄₈E150DSLN 3304 1962 1904 1635 2 x ⁷⁄₈ 2 x 2¹⁄₈E200DSTD 3304 1934 1904 1718 2 x 1¹⁄₈ 2 x 2¹⁄₈E200DLN 3304 1962 1904 1852 2 x 1¹⁄₈ 2 x 2¹⁄₈E200DSLN 4704 1962 1904 2108 2 x 1¹⁄₈ 2 x 2¹⁄₈E230DSTD 3304 1934 1904 1773 2 x 1¹⁄₈ 2 x 2¹⁄₈E230DLN 3304 1962 1904 1910 2 x 1¹⁄₈ 2 x 2¹⁄₈E230DSLN 4704 1962 1904 2246 2 x 1¹⁄₈ 2 x 2¹⁄₈E300DSTD 4704 1934 1904 2413 2 x 1³⁄₈ 2 x 2⁵⁄₈E300DLN 4704 1962 1904 2614 2 x 1³⁄₈ 2 x 2⁵⁄₈E300DSLN 6404 2002 1901 3126 2 x 1³⁄₈ 2 x 2⁵⁄₈E370DSTD 4704 1934 1904 2479 2 x 1³⁄₈ 2 x 3¹⁄₈E370DLN 4704 1962 1904 2668 2 x 1³⁄₈ 2 x 3¹⁄₈E370DSLN 6404 2002 1901 3230 2 x 1³⁄₈ 2 x 3¹⁄₈

Dimensions & Weights

All E-Series condensing units are supplied with a nitrogen holding charge.

© 2003 VES Andover Ltd.

Page 8: DX Condensing Units for both cooling and heat pump

Standard Features

Technical Details

Vertical free standing condensing unit with centrifugal fan

R407C refrigerant

Galvanised and fully painted to RAL 9010

Hermetic scroll compressors

Quiet operation

HP/LP protection

Volt free contacts for remote failure indication (fan, compressor 1, compressor 2)

Digital input connections for initiating fan and compressors

Remote on/off

VECON Cooling Cooling Heating No. No. No. of Power Max. Max Condenser AvailableModel capacity capacity capacity of of capacity consumption current starting fan pressure

kw evap. kw evap. kw circuits compressors steps kw amps current airflow @given5°C 8°C amps (m3/hr) airflow Pa

C22 19.4 22.0 15.2 1 1 1 7.8 16.6 104.7 5600 170C24 21.3 23.4 17.1 1 1 1 8.8 17.7 107.2 5600 160C28 25.6 29.1 20.5 1 1 1 10.6 20.1 126.7 5600 140C32 29.5 32.8 22.9 1 1 1 12.0 26.1 132.1 6500 300C38 36.2 39.9 27.6 1 1 1 14.6 32.8 165.2 9000 300C44D 38.9 42.9 30.3 2 2 2 15.6 33.2 121.3 11200 170C48D 42.5 48.3 34.2 2 2 2 17.8 35.4 120.4 11200 160C56D 51.2 56.5 40.9 2 2 2 21.2 40.2 146.8 11200 140C64D 58.9 66.1 45.9 2 2 2 24.0 52.2 158.2 13000 300C76D 72.5 79.7 55.2 2 2 2 29.2 65.6 198.0 18000 300C86D* 86.9 97.0 67.3 2 2 2 36.0 78.2 237.2 21000 270C100D* 100.7 111.6 77.1 2 4 4 43.6 89.4 195.8 23000 360

VECON Length Height Depth Weight Liquid line connection Suction line connectionModel mm mm mm kg size (inches) size (inches)

C22 1285 1375 803 205 ⁵⁄₈ ⁷⁄₈C24 1285 1375 803 265 ⁵⁄₈ ⁷⁄₈C28 1285 1375 803 275 ⁵⁄₈ ⁷⁄₈C32 1285 1375 803 280 ⁵⁄₈ ⁷⁄₈C38 1410 1440 803 360 ³⁄₄ 1³⁄₈ C44D 2340 803 1380 400 2 x ⁵⁄₈ 2 x ⁷⁄₈C48D 2340 803 1380 520 2 x ⁵⁄₈ 2 x 1¹⁄₈C56D 2340 803 1380 540 2 x ⁵⁄₈ 2 x 1¹⁄₈C64D 2340 803 1380 545 2 x ⁵⁄₈ 2 x 1³⁄₈C76D 2590 803 1445 670 2 x ³⁄₄ 2 x 1³⁄₈C86D 2 x 1570 2 x 1445 2 x 803 850 2 x ⁷⁄₈ 2 x 1⁵⁄₈C100D 2 x 1570 2 x 1445 2 x 803 900 2 x ⁷⁄₈ 2 x 1⁵⁄₈

VECON Sound power spectrum PWL per octave band dB(A) weighted Sound pressure Sound pressureModel 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz level 3m dB(A) level 10m dB(A)

C22 65 71 77 77 78 77 71 61 51C24 64 68 77 77 77 78 72 61 51C28 64 68 77 77 77 78 72 61 51C32 63 67 76 76 76 77 72 61 51C38 67 73 79 81 81 79 74 61 51C44D 66 72 79 80 81 80 74 61 51C48D 66 71 80 81 82 80 72 61 51C56D 67 72 80 81 82 81 73 62 52C64D 68 73 78 79 81 81 74 62 52C76D 70 76 82 93 84 82 76 63 53C86D 68 74 82 83 82 81 75 64 54C100D 70 78 84 85 85 84 78 65 55

Dimensions & Weights

Noise Data

Model no’s.: add suffix ‘C’ for cooling only or ‘P’ for heat pump unit.Cooling capacity based on evaporating at +5°C or +8°C with ambient temperature of 30°C.Heating capacity based on 21°C room temperature, -5°C external.All units supply voltage 400 volt 3 phase 50Hz, plus neutral.* Controls as a master and slave arrangement, supplied in 2 sections.All condensing units are supplied with a nitrogen holding charge as standard.

Optional Extras

On/off condenser head pressurecontrol (low ambient kit) includescrank case heater

Mains switch

Phase sequence protection

Soft starter (reducing peak compressor starting current by 40%)

Hot gas bypass

Vertical discharge kit

High static discharge kit - to 350Pa

Indoor Ducted Condensing Unit

CSERIES

Condensing

Units