DUW/DUX 1.0 DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS Producing Quality Heating & Cooling Equipment For Over 50 Years United Electric Company, L.P. 501 Galveston St. • Wichita Falls, TX 76301 • 940-397-2100 • Fax: 940-397-2166 • www.magicaire.com PI 08/05 3M MAGIC AIRE DU SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat DUW/DUX 1.0

Upload: trankiet

Post on 28-Apr-2018

273 views

Category:

Documents


11 download

TRANSCRIPT

Page 1: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

1 DUW/DUX 1.0

DUW/DUX SERIES1.5 THROUGH 5 TON

VERTICAL OR HORIZONTAL FAN COIL UNITS

Producing Quality Heating & Cooling Equipment For Over 50 Years

United Electric Company, L.P.501 Galveston St. • Wichita Falls, TX 76301 • 940-397-2100 • Fax: 940-397-2166 • www.magicaire.com

PI 08/05 3M

MAGIC AIRE DU SERIES FAN COILS ARE ETLCLISTED IN ACCORDANCE WITH UL 1995

AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

The Premium Quality Fan Coil Unitsfor Vertical, Horizontal (Left or Right)

Application with Direct Expansion,Hydronic or Electric Heat

DUW/DUX 1.0

Page 2: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

2

• SEER Ratings to 13+

• 24v 40 VA transformer and relay(s)

• 1" throwaway filter

• Two speed motors w/ thermal overloadprotection

• Hot Water Coils (Capacity to 124,000 BTU/H)with optional 115v pump assembly

• 3 and 4 row copper tube/aluminum fin DX coils tomatch most heat pump condensing units have pistonmetering refrigerant control

• Multiple access panels for easy servicing

• All metal parts are fabricated from heavy gaugegalvannealed steel w/polyurethane coating for thebest finish in the industry

• All interior surfaces are fully insulatedw/material to comply w/NFPA 90A and 90B

• Low RPM oversized fans are balanced forquiet, vibration free operation

DUX

• 1" throwaway filter

• Three speed motors w/ thermal overloadprotection

• Hot Water Coils (Capacity to 124,000 BTU/H)with optional 115v pump assembly

• 3 and 4 row water coils

• Electric heating elements to 20KW

• Multiple access panels for easy servicing

• All metal parts are fabricated from heavy gaugegalvannealed steel w/ polyurethane coating for

the best finish in the industry

• All interior surfaces are fully insulatedw/material to comply w/NFPA 90A and 90B

• Low RPM oversized fans are balanced forquiet, vibration free operation

• 24v transformer and fan relay

DUW

Magic Aire DUW/DUX Series fan coils are designed for upscale homes, apartments andcondominiums. Engineered with the distributor and installer in mind, one unit satisfies all demands.

Additional features include:

DU SERIES

Page 3: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

3 DUW/DUX 1.0

DU SERIES

Information subject to change without notice.

The Premium Quality, High Seer CombinationFan Coil Units for Vertical and Horizontal Applicationwith Hydronic or Electric Heat

Magic Aire® DU Series Fan Coils are designedfor upscale homes, apartments, and condominiums.Engineered with the distributor and installer in mind,one unit satisfies all demands.

All From One Unit!

Horizontal Left Hand

Horizontal Right Hand

Vert

ical U

pflo

w

Page 4: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

4

DUW UNIT DIMENSIONAL INFORMATION

NOTES:(1) Dimensions F, H, and K are for no heatand hydronic heat units. Dimensions G, J,and L apply to electric heat units only.(2) Return air openings – Side return airopenings require field modification.(3) On 60-DU electric heat units1/2HP-230v-1ø.(4) Hot Water Pump Module (not shown)is 115v (.52 FLA).

TOP VIEW(Hot WaterHeat Unit)

STANDARDONE PIECECABINET(Cooling

& Heating)

TWO PIECECABINET

LEFT VIEW FRONT VIEW RIGHT VIEW

OPTIONAL HOT WATEROR ELECTRIC HEATERSECTION FORFIELD INSTALLATION

COOLING SECTION

FILTERACCESS

PANEL

BLOWER/MOTORACCESS PANEL

HOT WATER COIL& PUMP MODULE/ELECTRIC HEATACCESS PANEL

SUPPLY

RETURN

PRIMARY &SECONDARYDRAIN CONN.3/4" NPT

OPTIONAL RIGHT ORLEFT SIDE RETURN(FIELD MODIFICATIONW/SIDE RETURNFILTER KIT)

SUPPLYRETURN

KNOCKOUTFORELECTRICALCONNECTIONS(BOTH SIDES)

KNOCKOUTFORELECTRICALCONNECTIONS(BOTH SIDES)

Page 5: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

5 DUW/DUX 1.0

AIRFLOW DATA DUW-B SERIES FAN COILCFM @ .00" – .50" ESP

NOTE: All data assumes dry cooling unit.

UNIT ELECTRICAL INFORMATION

NOTE: 10, 15 & 20KW require 2 supply circuits.

gniretnE)F(pmeTriA

)F(pmeTretaWgniretnE

001 o 011 o 021 o 031 o 041 o 051 o 061 o 071 o 081 o

05 o 914. 005. 975. 566. 247. 838. 719. 000.1 090.1

55 o 673. 064. 445. 926. 807. 197. 378. 369. 840.1

06 o 533. 914. 005. 975. 566. 247. 838. 719. 000.1

56 o 092. 673. 064. 445. 926. 807. 197. 378. 369.

07 o 152. 533. 914. 005. 975. 566. 247. 838. 719.

57 o 502. 092. 673. 064. 445. 926. 807. 197. 378.

08 o 761. 152. 533. 914. 005. 975. 566. 247. 838.

HOT WATER HEATING CORRECTION FACTORS

jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
jackr
Line
Page 6: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

6

DUWB-3 Coil Capacities02

4-D

UW

B-3

036-

DU

WB

-304

8-D

UW

B-3

060-

DU

WB

-3

2 Row Heating 3 Row Heating

024-

DU

WB

-2H

W03

6-D

UW

B-2

HW

024-

DU

WB

-3H

W03

6-D

UW

B-3

HW

Page 7: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

7 DUW/DUX 1.0

DUWB-4 Coil Capacities02

4-D

UW

B-4

036-

DU

WB

-404

8-D

UW

B-4

060-

DU

WB

-4

3 Row Heating 4 Row Heating

048-

DU

WB

-3H

W06

0-D

UW

B-3

HW

048-

DU

WB

-4H

W06

0-D

UW

B-4

HW

LWT LWT LWT

Page 8: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

8

Unit Dimensional Information

DUX SERIES

Page 9: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

9 DUW/DUX 1.0

Airflow Data DUX-B Series Fan CoilCFM @ .00" – .50" ESP

NOTE:

DUX SERIES

Page 10: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

10

NOTES:1. IMPORTANT – When application calls for DUX series used inconjunction with a heat pump, contact factory for ratings and to confirmcompatability with specific outdoor unit models.

2. DX cooling capacities are computer generated evaporator ratingsbased on specific entering conditions listed in the table. Actual perfor-mance with different condensing units may vary.

3. Contact factory for S.E.E.R. ratings with most major manufacturers'condensing units.

Direct ExpansionCoil Cooling Capacities

Hot WaterCoil Heating Capacities

DUX SERIES

4. When ordering DUX series units with hydronic heat, specifywhether pump module is required, and if so, whether it is required factoryinstalled or shipped separately as a kit (See LIST PRICES fordetails).

5. Contact the factory for wiring diagrams of all unit combinations.

6. Due to continuous efforts to improve our products, all specificationssubject to change without notice.

Page 11: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

11 DUW/DUX 1.0

DescriptionDUX series multi-position air handlers are available witha Multi-Function Controller that reduces the number ofelectrical connections and field supplied parts required to installthese units with boilers, pumps and condensing units.

Heating: Air handlers can now be directly wired from the boilerto the air handler without adding additional relays or relatedcontrols. Multiple air handlers may be connected to a single, high-efficiency natural gas or oil fired hot water boiler to providecomplete, whole house hydronic space heating. Each air handlerincludes a high-efficiency cooling coil, a separate hot water coil,drain pan,115, 208, 230 volt three speed blower motor, throwawayfilter and a 24V transformer.

Cooling: These air handlers are completely compatible with allsplit system type condensing units. Cooling coils in the DUX-HWair handlers are extra-large and engineered to offer coolingefficiencies to 13 SEER, depending on the condensing unit used.

DX Cooling / Boiler HeatingHeating Cycle1. Boiler Start Relay: Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler.2. Heating Cycle Blower Delay: User selectable 1, 3, or 4 minutes delay of the blower start to allow the coil to be preheated before

the blower energizes.Cooling Cycle1. Cooling Cycle Blower Delay: Maximizes cooling efficiency by allowing the blower to run 1 to 100 seconds after the

thermostat is satisfied.2. Horizontal Drain Pan: Factory installed. (re-positions within cabinet for right-to-left airflow)3. Drain Connections: Primary and secondary on cooling coil.Optional Features1. Freeze Protector: (Optional freeze protector switch required) Reduces the possibility of the water coil freezing by switching the

pump on if the water temperature is nearing a freezing condition.2. Aquastat: An optional aquastat is an available feature that ensures that there is hot water available prior to fan start up.Additional Standard Features1. The diagnostic lights show full functionality of the Fan Control. The green light should always be on indicating that power is

connected. Red lights indicate fan operation for heating and cooling modes.2. Pump dry contact activated for 2 minutes every 24 hours (boiler contacts not activated). User selectable.3. Pump dry contacts activated for 30 seconds every two weeks (boiler contacts not activated). User selectable.4. Compatible with most major brands of split condensing units.

Features Include:• Diagnostic Indicator Lights• 100% Factory Tested• Automatic Multi-Speed Switching• Prevents False Calls for Fan Operation• Simplified Wiring• Universal Thermostat Compatibility• Contractor Friendly PC Board Layout• Increased Operating Efficiency• Available in 115, 208, 230 volts• Made in USA

DUX SERIESMULTI-FUNCTION CONTROLLER

Page 12: DUW/DUX Series - Valtec · DUW/DUX SERIES 1.5 THROUGH 5 TON ... When application calls for DUX series used in conjunction with a heat pump, ... ARI 410 ARI 210

12DUW/DUX 1.0

United Electric Company, L.P.501 Galveston St. • Wichita Falls, TX 76301 • 940-397-2100 • Fax: 940-397-2166 • www.magicaire.com

PI 08/05 3M

MAGIC AIRE DU SERIES FAN COILS ARE ETLCLISTED IN ACCORDANCE WITH UL 1995

AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

• Cabinets shall be fabricated of LFQ (min) steel.External parts are to be made with a polyure-thane based powder coated heavy gaugegalvanealed, while internal parts are to be builtfrom heavy gauge galvanized steel. Units shall pass500 hour salt spray test as described inASTM B-117• Coils are to be tested at 500 PSI for operationat 400 PSI guage. All water coils have air vents.

ENGINEERING SPECIFICATIONS

• Fan wheel bearings shall be self aligning,sealed cartridge, permanently lubricated ballbearings that provide dependable fan operationfor an average life of 200,000 hours (beltdrive only).• Variable pitch motor sheaves.

United Electric Company designs and builds its Magic Aire® products tocomply and perform to one or more of the following standards:

WOLFRIA lareneG

tnempiuqEevirDtleBtnempiuqEevirDtceriD

012ACMA15EARHSA

034IRA044IRA

YTICAPACLIOC cinordyHnoisnapxEtceriD

014IRA012IRA

SGNITARDNUOSTCUDNI tnempiuqEgnivoMriA 86EARHSA033ACMA

SGNITSILYCNEGAYTEFAS slioC#tropeRLU

tnempiuqE

#tropeRLTE

702LU8343AS

632#2.22CASC/NAC5991-LU/ISNA

398194

SNOITACIFICEPSLAIRETAM lateMteehS

gnibuTreppoC

munimulA

525AMTSA725AMTSA

86BMTSA57BMTSA88BMTSA152BMTSA902BMTSA

STNENOPMOCROJAM srotoM

eriWlacirtcelE

sretliF

ssalgrebiF

tniaP

ASC/LUAMENASC/LUASC/LU

LU25EARHSA

181LU)05/52(327LU

48-EMTSA711BMTSA