ducted - lg usa · why lg ducted air conditioning designed for the way you live, our ducted air...
TRANSCRIPT
DUCTED AIR CONDITIONERS
Come home to comfort with LG
LG makes life good by connecting with the real needs and desires of our customers and innovating around them. We passionately believe in improving the day-to-day lives of Australians via forward-thinking technological advancement.
Why LG Ducted Air Conditioning
Designed for the way you live, our ducted air conditioners can be installed in a new home or tailored to an existing one. Our ducted units can typically be installed discreetly in residential houses - so you can create a space that’s cool, comfortable and stylish.
To give you peace of mind, we also provide a 5 year parts and labour warranty on our ducted systems, so comfort will be with you for years to come.
With LG Ducted System air conditioning products, you’ll also enjoy benefits such as:
• Optional Wi-Fi Control - so that you can control your unit with your Smartphone, even when you’re not at home*.
• Improved Energy Efficiency - The latest Inverter technology from LG helps to lower cooling costs in the summer
• Zone Control - take control of up to 8 zones with the LG premium controller and indicate each zone name such as Office, Hallway, etc
For ease of installation, energy efficiency and flexibility to design your home stylishly, LG ducted air conditioning systems are the smart choice.
*Wi-Fi Dongle Module required. Sold separately.Feature can be accessed using LG SmartThinQ App on Android (v 4.1or later) iOS (v iOS9 or later) smartphone. Internet connection required.
Come Home To Comfortwith LG air conditioners
MODEL LINE-UP
176 177
COM
MERC
IAL
27dB(A)
55dB(A)Of f ice
78dB(A)Typing
40dB(A)Library
50dB(A)Talking
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Air intake at the rear or bottomAir intake at the only rear
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional Standard Inverter Low Static Duct
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CM18R N10 CM24R N10
Capacity Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.8Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2
Power Input (Set)Cooling Nom kW 1.46 2.03Heating Nom kW 1.60 2.20
Power Input (Indoor)Min / Max (ESP 2.5mmAq) W 50 / 80 50 / 90Min / Max (ESP 8.0mmAq) W 90 / 160 100 / 180
Running Current Cooling / Heating Nom A 6.5 / 7.1 9.0 / 9.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50EER 3.42 3.35 COP 3.74 3.40 SEER 6.30 6.81SCOP 4.15 4.01Pdesign (@-10°C) kW 4.1 5.4 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 278 / 1,383 350 / 1,890
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32Sound Power Cooling Max dBA 59 60Dehumidification Rate l/h 1.5 2.5Dimensions Body W x H x D mm 900 x 270 x 700 900 x 270 x 700Net Weight Body kg 26.5 26.5 External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147)
OUTDOOR UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary
Airflow Rate Nom m3/min 50 58
Sound PressureCooling Nom dBA 47 48
Heating Nom dBA 52 52
Sound Power Cooling Max dBA 63 67
Dimensions W x H x D mm 870 x 650 x 330 950 x 834 x 330
Net Weight kg 44.8 56.1
Refrigerant
Type R32 R32
Charge g 1,100 1,600
Additional Charge (after 7.5m) g/m 20 35
GWP 675 675
t-CO2 eq 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5
Transmission Cable No. x mm2 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50
Piping Elevation Difference IDU - ODU Max m 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)
Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)
HIGH STATIC PRESSURE- CM18R / CM24R
UU24WRUU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT(LOW STATIC PRESSURE)
SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
176 177
COM
MERC
IAL
27dB(A)
55dB(A)Of f ice
78dB(A)Typing
40dB(A)Library
50dB(A)Talking
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Air intake at the rear or bottomAir intake at the only rear
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional Standard Inverter Low Static Duct
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CM18R N10 CM24R N10
Capacity Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.8Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2
Power Input (Set)Cooling Nom kW 1.46 2.03Heating Nom kW 1.60 2.20
Power Input (Indoor)Min / Max (ESP 2.5mmAq) W 50 / 80 50 / 90Min / Max (ESP 8.0mmAq) W 90 / 160 100 / 180
Running Current Cooling / Heating Nom A 6.5 / 7.1 9.0 / 9.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50EER 3.42 3.35 COP 3.74 3.40 SEER 6.30 6.81SCOP 4.15 4.01Pdesign (@-10°C) kW 4.1 5.4 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 278 / 1,383 350 / 1,890
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32Sound Power Cooling Max dBA 59 60Dehumidification Rate l/h 1.5 2.5Dimensions Body W x H x D mm 900 x 270 x 700 900 x 270 x 700Net Weight Body kg 26.5 26.5 External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147)
OUTDOOR UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary
Airflow Rate Nom m3/min 50 58
Sound PressureCooling Nom dBA 47 48
Heating Nom dBA 52 52
Sound Power Cooling Max dBA 63 67
Dimensions W x H x D mm 870 x 650 x 330 950 x 834 x 330
Net Weight kg 44.8 56.1
Refrigerant
Type R32 R32
Charge g 1,100 1,600
Additional Charge (after 7.5m) g/m 20 35
GWP 675 675
t-CO2 eq 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5
Transmission Cable No. x mm2 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50
Piping Elevation Difference IDU - ODU Max m 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)
Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)
HIGH STATIC PRESSURE- CM18R / CM24R
UU24WRUU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT(LOW STATIC PRESSURE)
SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
Indoor Unit Outdoor UnitCooling Capacity (kW)
Min ~ Rated ~ Max
Heating Capacity (kW)
Min ~ Rated ~ Max
UBN
24R
2.8 ~ 6.8 ~ 7.8 3.2 ~ 7.5 ~ 8.3
UBN
36R
4.5 ~ 9.5 ~ 13.0 5.0 ~ 10.8 ~ 13.7
SLIM DUCTED R32
176 177
COM
MERC
IAL
27dB(A)
55dB(A)Of f ice
78dB(A)Typing
40dB(A)Library
50dB(A)Talking
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Air intake at the rear or bottomAir intake at the only rear
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional Standard Inverter Low Static Duct
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CM18R N10 CM24R N10
Capacity Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.8Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2
Power Input (Set)Cooling Nom kW 1.46 2.03Heating Nom kW 1.60 2.20
Power Input (Indoor)Min / Max (ESP 2.5mmAq) W 50 / 80 50 / 90Min / Max (ESP 8.0mmAq) W 90 / 160 100 / 180
Running Current Cooling / Heating Nom A 6.5 / 7.1 9.0 / 9.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50EER 3.42 3.35 COP 3.74 3.40 SEER 6.30 6.81SCOP 4.15 4.01Pdesign (@-10°C) kW 4.1 5.4 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 278 / 1,383 350 / 1,890
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32Sound Power Cooling Max dBA 59 60Dehumidification Rate l/h 1.5 2.5Dimensions Body W x H x D mm 900 x 270 x 700 900 x 270 x 700Net Weight Body kg 26.5 26.5 External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147)
OUTDOOR UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary
Airflow Rate Nom m3/min 50 58
Sound PressureCooling Nom dBA 47 48
Heating Nom dBA 52 52
Sound Power Cooling Max dBA 63 67
Dimensions W x H x D mm 870 x 650 x 330 950 x 834 x 330
Net Weight kg 44.8 56.1
Refrigerant
Type R32 R32
Charge g 1,100 1,600
Additional Charge (after 7.5m) g/m 20 35
GWP 675 675
t-CO2 eq 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5
Transmission Cable No. x mm2 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50
Piping Elevation Difference IDU - ODU Max m 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)
Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)
HIGH STATIC PRESSURE- CM18R / CM24R
UU24WRUU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT(LOW STATIC PRESSURE)
SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
5LG Ducted Air Conditioners
R410AHIGH STATIC DUCTEDIndoor Unit Outdoor Unit
Cooling Capacity (kW)
Min ~ Rated ~ Max
Heating Capacity (kW)
Min ~ Rated ~ Max
B30A
WY7
G6
B30AWYN7G6 B30AWYU4G6
2.5 ~ 8.8 ~ 9.6 2.7 ~ 9.4 ~ 11.1
B36A
WY7
G6
B36AWYN7G6 B36AWYU3G6
3.2 ~ 10.5 ~ 13.0 3.4 ~ 13.0 ~ 13.7
B42A
WY7
G6
B42AWYN7G6 B42AWYU3G6
4.0 ~ 12.5 ~ 14.8 4.0 ~ 15 ~ 16.5
B55A
WY7
G6
B55AWYN7G6 B55AWYU3G6
4.8 ~ 15.0 ~ 15.8 4.8 ~ 17.0 ~ 18.0
B62A
WY9
L6
B62AWYN9L6 B62AWYU7L6
7.2 ~ 18.0 ~ 19.8 8.2 ~ 20.6 ~ 22.7
B70A
WY9
L6
B70AWYN9L6 B70AWYU7L6
8.0 ~ 20.0 ~ 22.0 9.0 ~ 22.6 ~ 24.9
SLIM DUCTED R32
6
E.S.P. (External Static Pressure) ControlThis function easily controls volume of the air by a remote controller. The BLDC motor can control fan speed and air volume regardless of the external static pressure. Additional accessories are not required to control air flow.
High Head Drain PumpHigh head drain pump automatically drains water up to a height of 200mm of drain-head height. It provides the perfect solution for draining of water. (Standard Inverter : Accessory (ABDPG) / Low-Static Duct : Included)
Comfort Cooling / Heating
Comfort Cooling / Heating
Over Cooling / Heating
Short Piping
Weak Cooling / Heating
Long Piping
Without E.S.P. Control E.S.P. Control
Drain Pipe Slope (1/50 ~ 1/100)
Wat
er d
rain
age
up to
700
mm
450mm
Flexible Drain Hose
Fixture
Drain Pipe
300mm
CEILING CONCEALED DUCTSINGLE SPLIT KEY FEATURES
172 173
COM
MERC
IAL
CEILING CONCEALEDDUCT
E.S.P. (External Static Pressure) ControlThis function easily controls volume of the air by a remote controller. The BLDC motor can control fan speed and air volume regardless of the external static pressure. Additional accessories are not required to control air flow.
High Head Drain PumpHigh head drain pump automatically drains water up to a height of 200mm of drain-head height. It provides the perfect solution for draining of water. (Standard Inverter : Accessory (ABDPG) / Low-Static Duct : Included)
Comfort Cooling / Heating
Comfort Cooling / Heating
Over Cooling / Heating
Short Piping
Weak Cooling / Heating
Long Piping
Detachable Drain Pump
Available for Natural Drainage
Conventional E.S.P. Control
Drain Pipe Slope (1/50 ~ 1/100)
Wat
er d
rain
age
up to
700
mm
450mm
Flexible Drain Hose
Fixture
Drain Pipe
300mm
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT
7LG Ducted Air Conditioners
Two Thermistors ControlThe indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can better optimise indoor air temperature for a more comfortable environment.
Operation for Multiple Rooms
Using a spiral duct (Embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously. Also, zone control is available with zone controller accessory (ABZCA)
Zone control features• Controls different zones (up to 4 zones) by external thermostat (AC a24V)• Maintain proper air volume of each zone• Auto variation of dampers• Auto control of fan speed and On / Off operation
Compares temperatures sensed from different positions, and automatically selects the optimum temperature for users
174 175
COM
MERC
IALTwo Thermistors Control
The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.
Minimized HeightNew mid-static ducts provide ideal solution for installation in limited space.
Operation for Multiple RoomsUsing a spiral duct (Embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously.Also, zone control is available with zone controller accessary (ABZCA)
Zone control features• Controls different zones (up to 4 zones) by external thermostat (AC a24V)• Maintain proper air volume of each zone• Auto variation of dampers• Auto control of fan speed and On / Off operation
Wide Operation RangeRemote Controller Thermistor(PREMTB001, PREMTB100)
Indoor Unit Thermistor
Compares temperatures sensed fromdifferent positions, and automaticallyselects the optimum temperaturefor users
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor)
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor) Easily Detach / Attach Filter
270mm
8/10kW 12.5kW
Standard Inverter Standard InverterConventional
298mm
270mm
Conventional
380mm
270mm
Outdoor temperature for cooling operation (°C DB) Outdoor temperature for heating operation (°C WB)
Easy Service & MaintenanceUsers are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and the other for fan/motor. The user can easily detach and re-attach the filter in the available limited space.
STANDARD INVERTER
R32 R410A
2.5~7 kW 10~15 kW 20.0/25.0 kW
-18
18
-28
18
-15
48
-15
48
-18
18
-20
48
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT
Zone Controlsub PCB
Indoor Unit(Duct Type)
ROOM1 ROOM2
ROOM3 ROOM4
Thermostat Temperature sensor
Temperature sensor Temperature sensor
174 175
COM
MERC
IALTwo Thermistors Control
The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.
Minimized HeightNew mid-static ducts provide ideal solution for installation in limited space.
Operation for Multiple RoomsUsing a spiral duct (Embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously.Also, zone control is available with zone controller accessary (ABZCA)
Zone control features• Controls different zones (up to 4 zones) by external thermostat (AC a24V)• Maintain proper air volume of each zone• Auto variation of dampers• Auto control of fan speed and On / Off operation
Wide Operation RangeRemote Controller Thermistor(PREMTB001, PREMTB100)
Indoor Unit Thermistor
Compares temperatures sensed fromdifferent positions, and automaticallyselects the optimum temperaturefor users
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor)
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor) Easily Detach / Attach Filter
270mm
8/10kW 12.5kW
Standard Inverter Standard InverterConventional
298mm
270mm
Conventional
380mm
270mm
Outdoor temperature for cooling operation (°C DB) Outdoor temperature for heating operation (°C WB)
Easy Service & MaintenanceUsers are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and the other for fan/motor. The user can easily detach and re-attach the filter in the available limited space.
STANDARD INVERTER
R32 R410A
2.5~7 kW 10~15 kW 20.0/25.0 kW
-18
18
-28
18
-15
48
-15
48
-18
18
-20
48
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT
Zone Controlsub PCB
Indoor Unit(Duct Type)
ROOM1 ROOM2
ROOM3 ROOM4
Thermostat Temperature sensor
Temperature sensor Temperature sensor
CEILING CONCEALED DUCTSINGLE SPLIT KEY FEATURES
8
Minimised HeightNew mid-static ducts provide ideal solution for installation in limited space.
174 175
COM
MERC
IALTwo Thermistors Control
The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.
Minimized HeightNew mid-static ducts provide ideal solution for installation in limited space.
Operation for Multiple RoomsUsing a spiral duct (Embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously.Also, zone control is available with zone controller accessary (ABZCA)
Zone control features• Controls different zones (up to 4 zones) by external thermostat (AC a24V)• Maintain proper air volume of each zone• Auto variation of dampers• Auto control of fan speed and On / Off operation
Wide Operation RangeRemote Controller Thermistor(PREMTB001, PREMTB100)
Indoor Unit Thermistor
Compares temperatures sensed fromdifferent positions, and automaticallyselects the optimum temperaturefor users
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor)
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor) Easily Detach / Attach Filter
270mm
8/10kW 12.5kW
Standard Inverter Standard InverterConventional
298mm
270mm
Conventional
380mm
270mm
Outdoor temperature for cooling operation (°C DB) Outdoor temperature for heating operation (°C WB)
Easy Service & MaintenanceUsers are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and the other for fan/motor. The user can easily detach and re-attach the filter in the available limited space.
STANDARD INVERTER
R32 R410A
2.5~7 kW 10~15 kW 20.0/25.0 kW
-18
18
-28
18
-15
48
-15
48
-18
18
-20
48
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT
Zone Controlsub PCB
Indoor Unit(Duct Type)
ROOM1 ROOM2
ROOM3 ROOM4
Thermostat Temperature sensor
Temperature sensor Temperature sensor
270mm
8/10kW 12.5kW
Standard Inverter Standard InverterConventional
298mm
270mm
Conventional
380mm
270mm
Easy Service & MaintenanceUsers are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and the other for fan/motor. The user can easily detach and re-attach the filter in the available limited space.
Wide Operation Range
Outdoor temperature for cooling operation (°C DB) Outdoor temperature for heating operation (°C WB)
STANDARD INVERTER
R32 R410A
2.5~7 kW 10~15 kW 20.0/25.0 kW
-18
18
-28
18
-15
48
-15
48
-18
18
-20
48
174 175
COM
MERC
IALTwo Thermistors Control
The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.
Minimized HeightNew mid-static ducts provide ideal solution for installation in limited space.
Operation for Multiple RoomsUsing a spiral duct (Embedded or flexible type) and stream chamber, it is possible to operate cooling / heating for several rooms simultaneously.Also, zone control is available with zone controller accessary (ABZCA)
Zone control features• Controls different zones (up to 4 zones) by external thermostat (AC a24V)• Maintain proper air volume of each zone• Auto variation of dampers• Auto control of fan speed and On / Off operation
Wide Operation RangeRemote Controller Thermistor(PREMTB001, PREMTB100)
Indoor Unit Thermistor
Compares temperatures sensed fromdifferent positions, and automaticallyselects the optimum temperaturefor users
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor)
Front Panel(Heat Exchanger)
Rear Panel(Fan / Motor) Easily Detach / Attach Filter
270mm
8/10kW 12.5kW
Standard Inverter Standard InverterConventional
298mm
270mm
Conventional
380mm
270mm
Outdoor temperature for cooling operation (°C DB) Outdoor temperature for heating operation (°C WB)
Easy Service & MaintenanceUsers are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and the other for fan/motor. The user can easily detach and re-attach the filter in the available limited space.
STANDARD INVERTER
R32 R410A
2.5~7 kW 10~15 kW 20.0/25.0 kW
-18
18
-28
18
-15
48
-15
48
-18
18
-20
48
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT
Zone Controlsub PCB
Indoor Unit(Duct Type)
ROOM1 ROOM2
ROOM3 ROOM4
Thermostat Temperature sensor
Temperature sensor Temperature sensor
9LG Ducted Air Conditioners
176 177
COM
MERC
IAL
27dB(A)
55dB(A)Of f ice
78dB(A)Typing
40dB(A)Library
50dB(A)Talking
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Air intake at the rear or bottomAir intake at the only rear
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional Standard Inverter Low Static Duct
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CM18R N10 CM24R N10
Capacity Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.8Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2
Power Input (Set)Cooling Nom kW 1.46 2.03Heating Nom kW 1.60 2.20
Power Input (Indoor)Min / Max (ESP 2.5mmAq) W 50 / 80 50 / 90Min / Max (ESP 8.0mmAq) W 90 / 160 100 / 180
Running Current Cooling / Heating Nom A 6.5 / 7.1 9.0 / 9.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50EER 3.42 3.35 COP 3.74 3.40 SEER 6.30 6.81SCOP 4.15 4.01Pdesign (@-10°C) kW 4.1 5.4 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 278 / 1,383 350 / 1,890
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32Sound Power Cooling Max dBA 59 60Dehumidification Rate l/h 1.5 2.5Dimensions Body W x H x D mm 900 x 270 x 700 900 x 270 x 700Net Weight Body kg 26.5 26.5 External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147)
OUTDOOR UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary
Airflow Rate Nom m3/min 50 58
Sound PressureCooling Nom dBA 47 48
Heating Nom dBA 52 52
Sound Power Cooling Max dBA 63 67
Dimensions W x H x D mm 870 x 650 x 330 950 x 834 x 330
Net Weight kg 44.8 56.1
Refrigerant
Type R32 R32
Charge g 1,100 1,600
Additional Charge (after 7.5m) g/m 20 35
GWP 675 675
t-CO2 eq 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5
Transmission Cable No. x mm2 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50
Piping Elevation Difference IDU - ODU Max m 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)
Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)
HIGH STATIC PRESSURE- CM18R / CM24R
UU24WRUU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT(LOW STATIC PRESSURE)
SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Air intake at the rear or bottomAir intake at the only rear
Previous Models Standard Inverter Low Static Duct
CEILING CONCEALED DUCT (LOW STATIC PRESSURE)
SINGLE SPLIT KEY FEATURES
10
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
CEILING CONCEALED DUCT (R32)
SINGLE SPLIT SPECIFICATIONS
Model Unit UBN24R UBN36R
Rated CapacityCooling kW 6.80 9.50
Heating kW 7.50 10.80
Capacity RangeCooling Min ~ Max kW 2.8 ~ 7.8 4.5 ~ 13.0
Heating Min ~ Max kW 3.2 ~ 8.3 5.0 ~ 13.7
Rated Power InputCooling kW 2.08 2.43
Heating kW 2.21 2.85
AEER / ACOP Cooling / Heating - 3.254 / 3.377 3.829 / 3.723
EER / COP Cooling / Heating - 3.277 / 3.400 3.909 / 3.789
Rated Current Cooling / Heating A 9.00 / 9.80 10.6 / 12.4
Max. Current (Full Load Amps)Indoor Unit A 1.6 2.3
Set A 17 28
Air Flow Rate L/s 300 / 275 / 242 533 / 466 / 400
External Static Pressure Pa 25 ~ 150 40 ~ 450
Indoor
Sound Level at 1.5m H / M / L Pressure dB(A) 35 / 34 / 32 36 / 34 / 33
Dimensions W x H x D mm 900 x 270 x 700 1,250 x 270 x 700
Weight kg 24.2 28.5
Outdoor
Sound Level at 1.5m Cooling / Heating Pressure dB(A) 48 / 52 52 / 54
Sound Power Level dB(A) 67 66
Dimensions W x H x D mm 950 x 834 x 330 950 x 1,380 x 330
Weight kg 56.1 87.5
Power Supply V / Phase / Hz 220-240, 1, 50 220-240, 1, 50
Circuir Breaker A 25 40
Compressor Type - Twin Rotary LG Inverter Scroll
RefrigerantType - R32 R32
Precharged Length m 7.5 7.5
Pipe Sizes
Liquid mm/inch ∅ 9.52 (3/8) ∅ 9.52 (3/8)
Gas mm/inch ∅ 15.88 (5/8) ∅ 15.88 (5/8)
Drain OD / ID mm ∅ 32 / 25 ∅ 32 / 25
Max. Pipe Length m 50 85
Max. Height Difference ODU ~ IDU m 30 30
Supply Air Opening H x W, Flange mm 200 x 857 200 x 1,206
Return Air Opening H x W, Flange mm 231x 850 230x 1,205
Continuous Operating RangeCooling °C DB - 15 ~ 48 - 15 ~ 48
Heating °C WB - 18 ~ 18 - 18 ~ 18
Demand Response - X X
UBN24RUBN36R
176 177
COM
MERC
IAL
27dB(A)
55dB(A)Of f ice
78dB(A)Typing
40dB(A)Library
50dB(A)Talking
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Air intake at the rear or bottomAir intake at the only rear
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional Standard Inverter Low Static Duct
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CM18R N10 CM24R N10
Capacity Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.8Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2
Power Input (Set)Cooling Nom kW 1.46 2.03Heating Nom kW 1.60 2.20
Power Input (Indoor)Min / Max (ESP 2.5mmAq) W 50 / 80 50 / 90Min / Max (ESP 8.0mmAq) W 90 / 160 100 / 180
Running Current Cooling / Heating Nom A 6.5 / 7.1 9.0 / 9.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50EER 3.42 3.35 COP 3.74 3.40 SEER 6.30 6.81SCOP 4.15 4.01Pdesign (@-10°C) kW 4.1 5.4 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 278 / 1,383 350 / 1,890
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32Sound Power Cooling Max dBA 59 60Dehumidification Rate l/h 1.5 2.5Dimensions Body W x H x D mm 900 x 270 x 700 900 x 270 x 700Net Weight Body kg 26.5 26.5 External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147)
OUTDOOR UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary
Airflow Rate Nom m3/min 50 58
Sound PressureCooling Nom dBA 47 48
Heating Nom dBA 52 52
Sound Power Cooling Max dBA 63 67
Dimensions W x H x D mm 870 x 650 x 330 950 x 834 x 330
Net Weight kg 44.8 56.1
Refrigerant
Type R32 R32
Charge g 1,100 1,600
Additional Charge (after 7.5m) g/m 20 35
GWP 675 675
t-CO2 eq 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5
Transmission Cable No. x mm2 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50
Piping Elevation Difference IDU - ODU Max m 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)
Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)
HIGH STATIC PRESSURE- CM18R / CM24R
UU24WRUU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT(LOW STATIC PRESSURE)
SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
11LG Ducted Air Conditioners
176 177
COM
MERC
IAL
27dB(A)
55dB(A)Of f ice
78dB(A)Typing
40dB(A)Library
50dB(A)Talking
Quiet Operation The noise level of low static ducts have been reduced, even though ESP has been increased.
CL09R N20 CL12R N20 CL18R N20 CL24R N30
Sound Pressure(High / Medium / Low)
dB (A) 31 / 28 / 27 31 / 28 / 27 36 / 34 / 31 39 / 35 / 32
Air intake at the rear or bottomAir intake at the only rear
Flexible Installation Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional Standard Inverter Low Static Duct
Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Definition of Power Input Nominal conditions – Performance tested under EN14511 3. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 5. This product contains fluorinated greenhouse gases (R32)
INDOOR CM18R N10 CM24R N10
Capacity Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.8Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2
Power Input (Set)Cooling Nom kW 1.46 2.03Heating Nom kW 1.60 2.20
Power Input (Indoor)Min / Max (ESP 2.5mmAq) W 50 / 80 50 / 90Min / Max (ESP 8.0mmAq) W 90 / 160 100 / 180
Running Current Cooling / Heating Nom A 6.5 / 7.1 9.0 / 9.8Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50EER 3.42 3.35 COP 3.74 3.40 SEER 6.30 6.81SCOP 4.15 4.01Pdesign (@-10°C) kW 4.1 5.4 Seasonal Energy Label Cooling / Heating A++ / A+ A++ / A+Annual Energy Consumption Cooling / Heating kWh 278 / 1,383 350 / 1,890
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)Drain O.D. / I.D. mm 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m3/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32Sound Power Cooling Max dBA 59 60Dehumidification Rate l/h 1.5 2.5Dimensions Body W x H x D mm 900 x 270 x 700 900 x 270 x 700Net Weight Body kg 26.5 26.5 External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147)
OUTDOOR UU18WR U20 UU24WR U40Compressor Type Twin Rotary Twin Rotary
Airflow Rate Nom m3/min 50 58
Sound PressureCooling Nom dBA 47 48
Heating Nom dBA 52 52
Sound Power Cooling Max dBA 63 67
Dimensions W x H x D mm 870 x 650 x 330 950 x 834 x 330
Net Weight kg 44.8 56.1
Refrigerant
Type R32 R32
Charge g 1,100 1,600
Additional Charge (after 7.5m) g/m 20 35
GWP 675 675
t-CO2 eq 0.74 1.08
Operation Range (Outdoor)Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm2 3C x 2.5 3C x 2.5
Transmission Cable No. x mm2 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50
Piping Elevation Difference IDU - ODU Max m 30 30
Piping ConnectionLiquid mm (inch) Ø 6.35 (1/4) Ø 9.52 (3/8)
Gas mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8)
HIGH STATIC PRESSURE- CM18R / CM24R
UU24WRUU18WR
STANDARD INVERTER (R32)
LG participates in the ECP programme for EUROVENT AC program.Check ongoing validity of certification : www.eurovent-certification.com
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT(LOW STATIC PRESSURE)
SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
HIGH STATIC DUCTED
R410A
12
13LG Ducted Air Conditioners
KEY FEATURES
RESIDENTIAL
The LG Smart ThinQ App lets you access and control your air conditioner with your smartphone* even when you're not at home, so you can come home to comfort. (Optional Wi-Fi dongle module sold separately).
*Wi-Fi Dongle Module required. Sold separately. Feature can be accessed using LG SmartThinQ App on Android (v 4.1 or later) iOS (v iOS9 or later) smartphone. Internet connection required.
Wi-Fi Smart Control CompatibleCome home to comfort
I Controlling & Monitoring I I Smart Diagnosis & Filter Manager I
I Integrated Home Appliances Control I
14
It is possible to control up to 8 zones from the premium controller and indicate a zone name such as Office, Hallway, etc. There are 18 names to choose from.
Zone Control
*Controllers sold separately.
Control up to 8 zones with the LG Premium Controller
KEY FEATURES
RESIDENTIAL
15LG Ducted Air Conditioners
Touch Colour Screen Controller*
Variable Airflow Technology (VAT)
Premium Controller
Variable Airflow Technology monitors the dampers so that only the required amount of air is discharged into the space. This helps to lower energy consumption by up to 20%*.
The LG Individual controller provides intuitive GUI with colour LCD and touch type interface Main Screen Selection - Choose between detailed and simple formats to meet your Schedule Control needs - Allows temperture control in conjunction with the time of day, allowing a customised setting that suits your lifestyle.
*Sold seperately.
Touch Screen
Premium Controller
Main Display Zone Control
Weekly Schedule
*LG internal test result based on previous 15kW Duct model B55AWYN7G5 vs. new 15kW Duct model B55AWYN7G6.
16
KEY FEATURES
CONTROLLERS
Premium Design with Intuitive Interface
Energy Monitoring
The luxurious design of the premium controller complements the interior design through a colourful display coupled with a simple user friendly button layout, making it easier to control.
The Premium Controller provides additional visibility on energy usage
Total accumulated power consumption only.
003 248.7 kWh
Premium Controller
Weekly / Monthly / Yearly (kWh & hr)
Year on year usage
Standard Controller
Zone ControlThe Premium Controller provides control over more zones (eight) and allows zones to be renamed.
On/Off only Zone naming is available.- Pre-set : Zone, Office, Hallway, Lobby, Room, Living, Kitchen, Etc
Premium Controller
17LG Ducted Air Conditioners
Filter Clean Information
Child Lock Function
The Premium Controller provides additional information on how long you have until you need to clean your filter.
The Premium Controller provides additional child lock options.
Only display
Premium Controller
Standard Controller
- All LockIt locks all button operation
- On/Off LockIt locks the On/Off button
- Mode LockIt locks the operation mode button
-Temperature Range LockIt is the function that can limit the range of the desired temperature
Lower limit: 16°C~30°CUpper limit: 18°C~30°C
Child Lock (All Lock) only
Premium Controller
Standard Controller
18
2 Set-Point Auto (Home Leave - Premium Controller Only)
Summer Hours Setting (Premium Controller Only)
The Premium Controller "Home Leave“ function sets the room temperature to stay between a range of two set temperature points when your home is unoccupied. This allows for a quicker return to a comfortable indoor environment when you return.
Summer time: The premium controller allows you to advance the time by 1 hour from the spring and return back in Autumn when the day gets shorter.
Ex) When it becomes AM 02:00 on the AEDST start date, the current time changes to AM 03:00, and when it becomes AM 02:00 of the AEDST end date, the current time changes to AM 01:00.
30.0˚C 16.0˚C
Home Leave OffHome Leave On
C 30˚C
H 16˚C
H 20˚C
C 28˚C
Premium Controller
Premium Controller
KEY FEATURES
CONTROLLERS
19LG Ducted Air Conditioners
KEY FEATURES SUMMARY
CONTROLLERS
CategoryStandard Premium
PREMTB001 PREMTA000
Size (mm, W x H x D) 121 x 120 x 15 137 x 121 x 16.5
Basic Control
On/Off, Fan Speed • •
Desired Temperature • •
Operation Mode • •
Reservation
Simple On/Off • •
Sleep • •
ON Time • •
OFF Time • •
Weekly • •
Yearly •
Holiday • •
Energy Monitor •
Time Limit Control •
Child Lock / All Lock • •
Time Display • •
Electric Failure Compensation • (3 hours) • (50 hours)
Wireless R/C IR Receiver • •
20
KEY FEATURES
RESIDENTIAL
The energy efficiency increase vs previous LG models (10.5kw), helps to lower operating costs. (Cooling AEER 14%↑ and Heating ACOP 24%↑)
Pressure control is more efficient* so it takes less time to reach your desired temperature.
Efficiency Comparison
LG Quick Cooling
Energy Efficiency
I Cooling Mode I I Heating Mode I
Cooling AEER is 14% higher than LG previous model based on 10.5kW model.
Heating ACOP is 24% higher than LG previous model based on 10.5kW model.
New ModelLG Previous Model
3.39
3.88Max 14% Increase
New ModelLG Previous Model
3.35
4.19Max 24% Increase
Pressure +Tempertaure Control
Time (min)
Out
let T
emp.
(°C)
32
12°C
Temperature Control
LG Conventional
Real Pressure
* vs. LG Conventional.
21LG Ducted Air Conditioners
Cooling Season energy simulation condition:
1) Model : Inverter B42AWYN7G5A / B42AWYU3G5A, Inverter B42AWYN7G6 / B42AWYU3G6
2) Location : Australia, Sydney
3) Cooling load : 12.5 kW
4) Operation time : 12pm – 9pm / Nov. – Feb.
5) Setting Temperature : AEER 3.80
6) Electric rate : 0.25 AUS$/kWh (for Residential)
7) Simulated by LG Energy Estimate Program
Cooling Season - Operation Cost ReductionThe latest Inverter technology from LG helps to lower cooling costs in the summer.
LG New Inverter
LG Previous Model
I LG Previous Model vs. LG New Inverter I
Operation cost ($ / Cooling Season)
145
109
25%
22
Unoccupied ModeWhen you leave your home unoccupied, instead of turning your system off and letting your home get hot or cold, you can press the dedicated unoccupied button which will set the room temperature to stay between a range of two set temperture points. This allows for a quicker return to a comfortable indoor environment when you return.
* Home Leave Set Temperature function can only be used in a 2 set control mode.
In occupied schedule mode, the set range is narrow to keep the indoor environment optimised as per temperature preference.
When you go out, instead of turning off your air conditioning, you can use unoccupied schedule mode. The set range is wide which allows the indoor environment to be restored to your preference quicker, than if you turned off your air conditioning.
CoolingCooling
HeatingHeating
Just setting one time, keeping comfortable
at all times
I Unoccupied II Occupied I
AM PM
KEY FEATURES
RESIDENTIAL
23LG Ducted Air Conditioners
Quiet ModeNight Silent Operation can reduce noise levels at night time by setting the dip switch on the PCB of the outdoor unit*.
*Based on cooling operation
When the technician sets to low noise operation, the cooling capacity may be decreased. The value of noise level is based on 15kW model.
Time
Noi
se L
evel
(dB(
A))
90
85
80
75
70
65
60
55
Mode End9 hours 18 hours Mode Start
Sound Level
Outdoor Temp.
Capacity
Up to 10dB(A)
24
External Controller Management*
Home Automation System*
Programmable thermostats have become popular due to their energy saving benefits, improved comfort and convenience.
A home automation system can control lighting, climate, entertainment systems and appliances.
* LG dry contact sold seperately. Please check with your dealer to ensure compatibility between your 3rd party thermostat and the LG Air Conditioner
* LG Modbus RTU gateway sold seperately.
Dry contact for thermostat
3rd partythermostat
• Operation On / Off• Thermo On / Off• Operation mode (Fan, Heat, Cool)• Set fan speed (Low, Middle, High)
KEY FEATURES
RESIDENTIAL
25LG Ducted Air Conditioners
Compact Indoor Unit
Double Drain Pan
The premium ducted split system has a small chassis. This small split type of indoor unit helps make it easy to install in narrow and small spaces*.
To prevent damage caused by accidental leakage or blocked drain, the indoor unit has an integrated safety tray.
Extra leakage protection
First Drain Pan for evaporator
Second Drain Pan (Base Panel Integrated Drain Pan)
* Image not to scale. For illustrative purposes only. Consult air conditioning installer for installation options.
26
Smart Diagnosis*
Detection of Refrigerant Change
Monitor the status of your air conditioner and diagnose problems by connecting it to a smartphone via a SIMs chip*.
The refrigerant levels are continuously monitored. If the amount of refrigerant drops to 60%, an alert will be sounded and running will be stopped.
*SIMs Module optional (technician only option).
SIM app: 1. Use a SIM's chip to connect a smartphone to an air-conditioner. 2. Monitor & diagnose in real time using the SIM app.
CH 35Refrigerant
Leakage 405060708090100
Rate
d Ca
paci
ty
Amount of Refrigerant in the system (%)
Error Zone
KEY FEATURES
RESIDENTIAL
27LG Ducted Air Conditioners
Full Load Consumption : 4.6 kW
Max. power Consumption : 3.6 kW
Max. power Consumption : 3.1 kW
Step 1
Step 2
• Based on 15 kW model• LG Internal test result
22% reduction
Peak Current Control
GoldFin™
Through the peak current control technology, it is possible to save energy and operational costs.
The gold-coloured special coating on the fin of the heat exchanger prevents corrosion, extending the life of the unit.
By limiting to the maximum running current, the air conditioner can avoid running on the peak current level.
This function can reduce energy cost during peak periods when electric charge is expensive.
I How to set dip switch I
Runn
ing
Curr
ent
Time
Peak
Cut-off
Limited Current
Energy Saving
Step 1
Step 2
33% reduction
28
SPECIFICATIONS
PREMIUM RANGE
B30AWY7G6B36AWY7G6
B42AWY7G6B55AWY7G6
Model Unit B30AWY7G6 B36AWY7G6 B42AWY7G6 B55AWY7G6
Rated CapacityCooling kW 8.8 10.5 12.5 15
Heating kW 9.4 13 15 17
Capacity RangeCooling Min ~ Max kW 2.5 ~ 9.6 3.2 ~ 13 4.0 ~ 14.8 4.8 ~ 15.8
Heating Min ~ Max kW 2.7 ~ 11.1 3.4 ~ 13.7 4.0 ~ 16.5 4.8 ~ 18.0
Rated Power InputCooling kW 2.58 2.75 3.35 4.6
Heating kW 2.32 3.1 3.8 4.68
AEER /ACOP Cooling / Heating - 3.39 / 4.0 3.79 / 4.1 371 / 3.93 3.25 / 3.62
EER / COP Cooling / Heating - 3.41 / 4.05 3.82 / 4.19 3.73 / 3.95 3.26 / 3.63
Rated Current Cooling / Heating A 11.4 / 10.3 12.2 / 13.8 14.9 / 16.9 20.4 / 20.8
Max. Current (Full Load Amps) A 17 29 29 29
Rated Air Flow Rate L/s 533 / 433 / 333 700 / 600 / 467 833 / 717 / 600 1000 / 833 / 667
Indoor
Sound Level at 1.5m H / M / L Pressure dB(A) 41 / 40 / 39 43 / 41 / 40 44 / 42 / 41 45 / 44 / 42
Dimensions W x H x D mm 1,320 x 400 x 534 1,320 x 400 x 534 1,320 x 400 x 534 1,320 x 400 x 534
Weight kg 48 48 52 52
Outdoor
Sound Level at 1m Cooling / Heating Pressure dB(A) 51 / 52 53 / 54 53 / 54 54 / 56
Sound Power Level dB(A) 64 65 66 68
Dimensions W x H x D mm 950 x 834 x 330 950 x 1,380 x 330 950 x 1,380 x 330 950 x 1,380 x 330
Weight kg 58.5 87.5 87.5 87.5
Power Supply V / Phase / Hz 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50
Circuit Breaker A 25 40 40 40
Compressor Type - Inverter Twin Rotary Inverter Scroll Inverter Scroll Inverter Scroll
RefrigerantType - R410A R410A R410A R410A
Precharged Length m 10 20 20 20
Pipe Sizes
Liquid mm/inch ∅ 9.52 (3/8) ∅ 9.52 (3/8) ∅ 9.52 (3/8) ∅ 9.52 (3/8)
Gas mm/inch ∅ 15.88 (5/8) ∅ 15.88 (5/8) ∅ 15.88 (5/8) ∅ 15.88 (5/8)
Drain OD / ID mm ∅ 32 / 25 ∅ 32 / 25 ∅ 32 / 25 ∅ 32 / 25
Max. Piping Length m 30 75 75 75
Max. Height Difference
ODU ~ IDU m 30 30 30 30
Supply Air Opening H x W, Flange mm 287 x 840 287 x 840 287 x 840 287 x 840
Return Air Opening Oval mm 317 x 1,172 317 x 1,172 317 x 1,172 317 x 1,172
Continuous Operating Range
Cooling °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48
Heating °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18
Demand Response - Capable Capable Capable Capable
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are in accordance with ASNZS3823.1.2
Cooling: - Indoor Temperature 27°C DB /19°C WB
- Outdoor Temperature 35°C DB /24°C WB
Heating: - Indoor Temperature 20°C DB / 15°C WB
- Outdoor Temperature 7°C DB / 6°C WB
29LG Ducted Air Conditioners
SPECIFICATIONS
STANDARD RANGE
B62AWYN9L6 B70AWYN9L6
Model Unit B62AWY9L6 B70AWY9L6
Rated CapacityCooling kW 18.0 20.0
Heating kW 20.6 22.6
Capacity RangeCooling Min ~ Max kW 7.2 ~ 19.8 8.0 ~ 22.0
Heating Min ~ Max kW 8.2 ~ 22.7 9.0 ~ 24.9
Rated Power InputCooling kW 5.47 6.47
Heating kW 5.49 6.19
EER / COP Cooling / Heating - 3.29 / 3.75 3.09 / 3.65
Rated Current Cooling / Heating A 9.3 / 9.6 10.9 / 10.5
Rated Air Flow Rate L/s 1,333 / 1,200 / 1,067 1,333 / 1,200 / 1,067
Indoor
Sound Level at 1.5m H / M / L Pressure dB(A) 43 / 41 / 40 43 / 41 / 40
Dimensions W x H x D mm 1,563 x 458 x 791 1,563 x 458 x 791
Weight kg 89 89
Outdoor
Sound Level at 1m Cooling / Heating Pressure dB(A) 59 / 60 59 / 60
Sound Power Level dB(A) 71 71
Dimensions W x H x D mm 1,090 x 1,625 x 380 1,090 x 1,625 x 380
Weight kg 144 144
Rated Power InputIndoor
V / Phase / Hz220-240, 1, 50 220-240, 1, 50
Outdoor 380-415, 3, 50 380-415, 3, 50
Circuit Breaker A 30 30
Compressor Type - Hermetically Sealed Scroll Hermetically Sealed Scroll
RefrigerantType - R410A R410A
Precharged Length m 15 15
Pipe Sizes
Liquid mm/inch ∅ 12.7 (1/2) ∅ 12.7 (1/2)
Gas mm/inch ∅ 22.8 (7/8) ∅ 22.8 (7/8)
Drain OD / ID mm ∅ 32 / 25 ∅ 32 / 25
Max. Piping Length m 75 75
Max. Height Difference
ODU ~ IDU m 30 30
Supply Air Opening H x W, Flange mm 286 x 1,044 286 x 1,044
Return Air Opening Oval mm 392 x 1,368 392 x 1,368
Continuous Operating Range
Cooling °C DB -20 ~ 48 -20 ~ 48
Heating °C WB -18 ~ 18 -18 ~ 18
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are in accordance with ASNZS3823.1.2
Cooling: - Indoor Temperature 27°C DB /19°C WB
- Outdoor Temperature 35°C DB /24°C WB
Heating: - Indoor Temperature 20°C DB / 15°C WB
- Outdoor Temperature 7°C DB / 6°C WB
30
ACCESSORIES
Control Method Objective/Use Unit Name and Model Function Parts Features
PI485
PMNFP14A1
To connect Outdoor unit to CNU or SimpleCentral Controller
• RS485 Converter with software• For Max.16 Indoor
• PCB Assembly• Bracket• Lead wire: 3ea• Screw 4EA• Tie wrap• Clamp• Manual
• 1set/1 Outdoor
Dry Contact
PDRYCB100
For connect Indoor unit to other Forced on/off Controller
• RS485 Converter with software
• PCB Assembly• Top case• Bottom case• Screw• Lead wire 3• Sub PCB set (1 leadwire + 1 sub PCB)• Manual
• 1set/1 Indoor unit
Dry Contact
PDRYCB400
For connect Indoor unit to other Forced on/off Controller
• Contact signal to air-con signal converter
• PCB Assembly• Top/Bottom case• Screw• Lead wire 3ea• Sub PCB set (1 leadwire + 1 sub PCB)• Manual
• 1set/1 indoor unit• 2 Contact points• No need AC input• Expected temperature setting is possible
*Dred/Dry contact.
INTERFACE DEVICE
PREMIUM DUCTED SYSTEM ACCESORIES*Model Description
PREMTB001 Standard Wired Wall Controller
PREMTA000 Premium Controller
PBZC80 Damper Controller 8 Zone
PQWRHQ0FDB Wireless Remote Control
ABDPG Mid Static Drain Pump
ABDP7 Drain Pump Kit (8.8kW - 15kW)
PBDP9 Drain Pump Kit (18kW - 20kW)
PWFMDD200 WiFi Dongle + 1.1m Cable
PWYREW000 10m Cable
ABZCA Damper 4 Zone Controller
*Refer to each model PDB for application accessories.
31LG Ducted Air Conditioners
Control Method Objective/Use Unit Name and Model Function Parts Features
BNU-LW
PLNWKB000
To connect PI485 to LONWORKS BMS system
• Interface between BMS and LG air-conditioners (LonMark certified : Operation system based on LNS)
• Interface Assembly
• 12V DC adaptor• Manual
• 64 indoor units• ACP function (central controller) included
BNU-BAC
PQNFB17C 0
To connect PI485 to BACnet BMS system
• Interface between BMS and LG air-conditioners (BTL certified : Operation system based on BACnet service)
• Interface Assembly• 12V DC adaptor• Manual
• 256 Indoor units• ACP function (central controller) included• BTL certification (B-ASC)
PDI STANDARD
PPWRDB000
To Power consumption Distribution of each indoor unit2-port
• Accumulation of total power consumption• Indication of current power in use• Indication of accumulated power for period• Indication of standby power (option setting)
• PDI Assembly Manual
• 1 PDI / 2 Outdoor
PDI Premium
PQNUD1S40
To power consumption distribution of each indoor unit8-port
• Accumulation of total power consumption • Indication of current power in use• Indication of accumulated power for period • Indication of standby power• Blackout protection
• PDI Assembly manual
• 1 PDI / 8 Outdoor
1) PI485 : Product Interface unit for RS 485 transmission
BUILDING MANAGEMENT DEVICES
ACCESSORIES
For more information visitlg.com/au/ducted-air-conditioning