(drups) and its integration in "uptime institute tier"

46
IT & INFRASTRUCTURE DATACENTERS CONGRESS Brussels, 13th of October 2016 Yves Jansen

Upload: lylien

Post on 23-Dec-2016

241 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: (DRUPS) and its integration in "Uptime Institute Tier"

IT & INFRASTRUCTURE DATACENTERS CONGRESS

Brussels, 13th of October 2016

Yves Jansen

Page 2: (DRUPS) and its integration in "Uptime Institute Tier"

DIESEL ROTARY UPS (DRUPS) AND ITS INTERGRATION IN 

« UPTIME INSTITUTE TIER » ARCHITECTURE BASED DATA 

CENTRES

Page 3: (DRUPS) and its integration in "Uptime Institute Tier"

EURO‐DIESEL SADRUPS : NO‐BREAK KSTIER STANDARDNO‐BREAK KS AND THE TIER STANDARD

Page 4: (DRUPS) and its integration in "Uptime Institute Tier"

HQ EURO‐DIESEL SA, Belgium, Liege

EURO‐DIESEL SA

Holland

Belgium

Established in 1989

HQ Liège, Belgium

Consolidated revenue :  103 million EUR

Total number of employees : 250

Subsidiaries in Germany, UK, France, USA, Singapore, Brazil, Middle East, United Arab Emirates, Turkey, Mexico and Russia

Worldwide distributor network

Focus on power quality solutions: DRUPS

France

The Netherlands

Belgium

Luxemburg

BrusselsLiège

Page 5: (DRUPS) and its integration in "Uptime Institute Tier"

World Largest DRUPS Testing Facility

• 6300 M²

• Production capacity > 200 systems

• 18 Test stands

• Indoor enclosure assembly 

• 50 & 60 Hz testing

• Load banks > 18 MW

• Load banks & recordings, software operated

The Facility built in 2009:

Page 6: (DRUPS) and its integration in "Uptime Institute Tier"

Power Quality

Page 7: (DRUPS) and its integration in "Uptime Institute Tier"

Building a NO‐BREAK KS® System

Page 8: (DRUPS) and its integration in "Uptime Institute Tier"

Stato‐Alternator Side View

ACCU‐ROTOR < 3000 RPM 

MAIN SHAFT 1500 OR 1800 RPM 

Page 9: (DRUPS) and its integration in "Uptime Institute Tier"

100 kVA to 2750 kVA (50Hz); 3000 kVA (60Hz)

Page 10: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® Conditioning Mode

Page 11: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® Conditioning Mode

•Voltage regulator •Harmonics filter•Improvement of Power factor•Elimination of Microcuts

Page 12: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® Independent Mode

Page 13: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® SYSTEM CONFIGURATIONS

FOR DATA CENTRES

Page 14: (DRUPS) and its integration in "Uptime Institute Tier"

UPTIME Institute Tier Standard: Topology

• The functionality

• The capacity

• The availability  ( or performance) 

Tier Standard Topology is an objective basis for comparing:

of a particular site infrastructure design topology against other sites 

Page 15: (DRUPS) and its integration in "Uptime Institute Tier"

UPTIME Institute Tier Standard: Topology

• The functionality

• The capacity

• The availability  ( or performance) 

Tier Standard Topology is an objective basis for comparing:

of a particular site infrastructure design topology against other sites 

Tier Standard describes criteria four differentiate classifications of  site infrastructure

Page 16: (DRUPS) and its integration in "Uptime Institute Tier"

System Configurations for Data Centres

Tier I

Active Capacity Components to Support the IT Load N

Distribution Paths 1

Concurrently Maintainable No

Fault Tolerance No

Compartmentalization No

Diesel Engine Function Engine Limited on Consecutive Hours of Operation

Uptime Institute Design Criteria

Page 17: (DRUPS) and its integration in "Uptime Institute Tier"

System Configurations for Data Centres

Tier I Tier II

Active Capacity Components to Support the IT Load N N+1

Distribution Paths 1 1

Concurrently Maintainable No No

Fault Tolerance No No

Compartmentalization No No

Diesel Engine Function Engine Limited on Consecutive Hours of Operation

Engine Limited on Consecutive Hours of Operation

Uptime Institute Design Criteria

Page 18: (DRUPS) and its integration in "Uptime Institute Tier"

System Configurations for Data Centres

Tier I Tier II Tier III

Active Capacity Components to Support the IT Load N N+1 N+1

Distribution Paths 1 1 1 Active and 1 Alternative Path

Concurrently Maintainable No No Yes

Fault Tolerance No No No

Compartmentalization No No No

Diesel Engine Function Engine Limited on Consecutive Hours of Operation

Engine Limited on Consecutive Hours of Operation

Engine NO Limit on Consecutive Hours of Operation

Uptime Institute Design Criteria

Page 19: (DRUPS) and its integration in "Uptime Institute Tier"

System Configurations for Data Centres

Tier I Tier II Tier III Tier IV

Active Capacity Components to Support the IT Load N N+1 N+1 N: After a failure

Distribution Paths 1 1 1 Active and 1 Alternative Path 2 Simultaneously Active

Concurrently Maintainable No No Yes Yes

Fault Tolerance No No No Yes

Compartmentalization No No No Yes

Diesel Engine Function Engine Limited on Consecutive Hours of Operation

Engine Limited on Consecutive Hours of Operation

Engine NO Limit on Consecutive Hours of Operation

Engine NO Limit on Consecutive Hours of Operation

Uptime Institute Design Criteria

Page 20: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®    Single System – Tier I design

• Active capacity element to support active load : N

• Distribution path: 1

• Concurrently Maintainable: NO

• Fault Tolerant: NOTIER 1

Page 21: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier II Design

TIER 2

Critical load

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+1

1

NO

NO

Page 22: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier II Design

TIER 2

Critical load

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+1

2

NO

NO

Page 23: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier III Design

TIER 3

Critical load

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+1

2

YES

NO

Page 24: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier III Design

TIER 3

Critical load

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+1

2

YES

NO

Page 25: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier 3 Design

TIER 3

Critical load

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+N

2

YES

YES

subject to interpretation TIER 4

Page 26: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier IV Design

2 NO-BREAK KS ® of 1000 kVA+ 2 NO-BREAK KS ® of 2000 kVA

ECMWF READING UK:

Page 27: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier IV Design

TIER 4

Critical load

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+N

2 Active

YES

YES

Page 28: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier IV Design

TIER 4

PROXIMUS GAM EVERE :

PROXIMUS MECHELEN:

PROXIMUS SURFHOUSE EVERE:  

4+4 NO-BREAK KS ® of 1000 kVA

2+2 NO-BREAK KS ® of 1600 kVA

2+2 NO-BREAK KS ® of 1000 kVA

Page 29: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® MV Parallel – Tier IV Design

TIER 4

PROXIMUS MACHELEN:   5+5 NO-BREAK KS ® of 1700 kVA

Page 30: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® LV Parallel – Tier IV Design

TIER 4

Critical load

50%

• Active capacity :

• Distribution path:

• Concurrently Maintainable: 

• Fault Tolerant:

N+N

2 Active

YES

YES

50%

Load repartition

Page 31: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® Distributed Redundant

66% 66% 66%

Load repartition

Page 32: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS® Distributed Redundant

TIER 4

• Active capacity element to support active load : N+N

• Distribution path: 2 active

• Concurrently Maintainable: YES

• Fault Tolerant: YES

Page 33: (DRUPS) and its integration in "Uptime Institute Tier"

SOME OF OUR MAJOR REFERENCESIN DATA CENTRES

Page 34: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®5  16 x 2500 kVA, 400V

Etisalat Data Centre, Khalifa City A, Abu Dhabi, UAE

Page 35: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®5  10 x 1600 kVA, 415 V

Meeza Data Center, Qatar

Page 36: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®5 SB  18 X 1650 kVA, 400V 

Standard Bank of South Africa , Samrand, Midrand

Page 37: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®5SB  2 x 2500 kVA, 13.8 kV

Telus Modular data center, Rimouski , Canada

Page 38: (DRUPS) and its integration in "Uptime Institute Tier"

Ascenty Data Center, Jundiaí, Brazil

NO‐BREAK KS®5SB 9 x 1700 kVA, 13,8 kV

Page 39: (DRUPS) and its integration in "Uptime Institute Tier"

Ascenty Data Center, Hortolândia, Brazil

NO‐BREAK KS®5SB 9 x 1700 kVA, 480 V

Page 40: (DRUPS) and its integration in "Uptime Institute Tier"

KEPPEL DATAHUB T27, Singapore

NO‐BREAK KS®5  6 x 2000 kVA, 415V

Page 41: (DRUPS) and its integration in "Uptime Institute Tier"

Cisco Systems TX‐DC2, Dallas, USA

NO‐BREAK KS®5 SB  8 x 2100 kW, 4.16 kV

Page 42: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®5 SB  16 x 2500 kVA, 400V

Natixis, France

Page 43: (DRUPS) and its integration in "Uptime Institute Tier"

Global Switch, London, UK

NO‐BREAK KS®5 26 x 2000 kVA, 11 kV

Page 44: (DRUPS) and its integration in "Uptime Institute Tier"

NO‐BREAK KS®5  8 x 2250 kVA, 11 kV

Global Switch, Sydney, Australia

Page 45: (DRUPS) and its integration in "Uptime Institute Tier"

Global Switch, Hong Kong

NO‐BREAK KS®7  12 x 2625 kVA, 11 kV

Page 46: (DRUPS) and its integration in "Uptime Institute Tier"

For More Information • Please See Us ......

Thank You For Your Attention • With Compliments

Speaker • EURO‐DIESEL SA