Druck- und Temperaturmesstechnik

GSoft / Testing and Callibratiion Technology / 25.03.2009

Testing- and Calibration Technology

Data logger evaluation software GSoft

1

Data logging in process

…with handheld CPH 6200 / CTH 6200 and data logger evaluation software GSoft

2

Handheld with evaluation software GSoft

Software features:

- Easy operation due to self-explanatory icon buttons- Zoom function available- Remote operation via PC possible- Data can be exported to Excel®, etc.- Language: English, German, France, Spain, ...

CPH 6200 CTH 6200

Instrument features:

- CPH 6200 and CTH 6200 can store measurement data (Logger integrated)- Possibility of cyclic storage of the measurement data- Storage up to 16,200 measurement data (depending on the model)

pressure

temperature

3

2sec

Starting logger (measurement storage)

Logger activeMeasuring mode

Cyclic measurement storage is active. Logger

active: until stopped manual by the user or logger reaches total

storage capacity (up to 16,200 measurement data)

Initial state:measuring mode*

*cyclic logger has been activated before via menu.

4

Button stops the logger Initial state:measuring mode

Stop logger?NOLogger active

Stop logger?YES?

Measuring mode

Cyclic measurement storage is active. Logger

can be stopped: by pressing

Safety function: should measurement storage be

stopped? Choice via

or

Stopping logger (measurement storage)

5

Measurement data

Transfer of the measurement data to PC via RS232- or USB-interface

GSoft offers the possibility to show the measurement data on PC as table or diagram

Connecting the Handheld with PC

6

User interface of software GSoft

7

1. Interface configuration

Click to choose the interface

8

1. Interface configuration

Confirmation of interface

9

2. Creating a connection with the Handheld

Search Handheld

10

3. Read actual status of the Handheld

Transfer actual status of the Handheld

11

Stored logger data are shown

Read logger data

4. Showing actual status of the Handheld

Sensor data at the moment when the actual status is read out

12

Create chart

Logger data are shown

5. Logger data are shown as table

13

Select data

6. Presettings of the graph

14

7. Logger data are shown as diagram

15

Further information1.) Graph options: zoom function

2.) Peak detection via min/max function

3.) Start logger, if any data are already in the logger

4.) Software update

5.) Outlook

6.) Product Support

16

After marking an area with the left mouse button, the zoomed graph will be shown

1.) Graph options: zoom function

17

1.) Graph options: zoom function

Via the scrolling button you can scroll your zoomed graph in every position you want

18

2.) Peak detection via min/max function

Available peak in the time span between 17:40:03 and 17:40:04

Actual measure data 17:40:04

In addition to the actual measured value, the min- and max-values also will be stored and can be shown in the graph. (Choice via the window “Create New Diagram”)

The sample shows, in the time span between 17:40:03 and 17:40:04 there was a peak of about 0,64 bar which will be read out and shown in the graph parallel to the actual measure data of the time 17:40:04.

19

3.) Start logger, if any data are already in the logger

Safety function: should the stored measurement data

really be cleared? Choice via

or

Button clears the existing measurement data

Initial state: New logger data can be stored

(see description above)

Clear existing logger data? NO?

Measuring mode

Measuring mode

Clear existing logger data? YES?

Delete old measurement data: by pressing

for 2seconds

2sec

20

4.) Software updateSoftware update on www.wika.de : //Download/Software/Calibration Technologyfor free.

21

4.) Software updateDownload file (update file) has to be stored in the same folder in which the program GSoft is located

22

4.) Software updateStarting the update file

To start the update, double-click on the update file

23

5.) OutlookPossibility to show pressure- and temperature data in one graph

Both data sets have to be stored as 2 files. Thus both files can be opened and displayed in one diagram.

24

5.) OutlookPossibility of „Copy and Paste“. Easy to import measurement data in a Excel-sheet