Page 1: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

National Energy Technology Laboratory

Driving Innovation ♦ Delivering Results

Victor KusumaNational Energy Technology Laboratory, AECOM

NETL Carbon Capture Technology Review Meeting 2016

Automated Post-combustion Flue Gas Membrane Performance Testing Skidat the National Carbon Capture Center

Page 2: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

2National Energy Technology Laboratory

Outline

• The NETL Post-combustion Membrane Testing Skid (PCMS)• Lessons learned • Initial testing results• Ongoing testing• Future outlook

Page 3: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

3National Energy Technology Laboratory

Our home at the PC4 Bench Scale Facility

Image courtesy of Patrick Crossley and Justin Anthony, Southern Company Services

PCMS

Page 4: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

4National Energy Technology Laboratory

Our home at the PC4 Bench Scale Facility

Image courtesy of Patrick Crossley and Justin Anthony, Southern Company Services

PCMS

Page 5: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

5National Energy Technology Laboratory

Post-Combustion Membrane Testing Skid

• The proving ground for our most promising membranes• Compact footprint: can be moved as one unit• Fully automated operation: set and forget

– Designed for multiday/multiweek experiments for medium/long term testing

Feed chiller

Electricals/Electronics

Monitor

Membrane+Circulator

GC

Flow control

Gas linesFeed pump

Page 6: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

6National Energy Technology Laboratory

Post-Combustion Membrane Testing Skid

• Based on standard constant pressure membrane testing system– Mixed gas analysis using gas chromatograph– Pressurizes feed up to 30 psig, filters particulate matter, and dehumidifies

feed to avoid condensation– Accepts hollow fiber modules and flat sheet modules

Flue MFC

MFC

PT

Argon MFC

0-50 sccm*

0-50 sccm

0-50 sccm

PT

PTC

PTC

15-30 psia

Chiller

Pumped to~30 psig+7 µm filters

FI

GC

15-30 psiaPrimary membrane moduleWater bath temp. control

5-80 °C

to flue gas return~2 slm feed bypass

FI

HMT

HMT

Page 7: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

7National Energy Technology Laboratory

Software and automation

• Embedded Windows 7 rugged computer/DAQ with custom LabVIEW-based software

• Enables “setup, start and walk away” operation philosophy• Up to 5 pre-programmed pressure/flow steps• Automated GC injections for mixed gas analysis from either feed or sweep

John O’Connor

NI cDAQ-9132

Page 8: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

8National Energy Technology Laboratory

Membrane assembly

Flat sheet membrane assemblyHollow fiber membrane assembly

(Single strand)

Typical area: 0.6 to 2.7 cm2

Cross-current flowTypical length: 10 cmCounter-current flow

Membrane module

Feed

Retentate

Sweep

Permeate

Page 9: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

9National Energy Technology Laboratory

December 2015 campaign timeline

12/7/15 12/8/15 12/9/15 12/10/15 12/11/15 12/12/15

12/13/15 12/14/15 12/15/15 12/16/15 12/17/15 12/18/15

• Primary task: install and confirm PCMS operating properly– Extensive tests at NETL minimizes installation and shakedown time at NCCC

• Secondary task: test membranes (24-hour tests)– 7 membranes successfully tested: 4 hollow fibers, 3 dense flat sheet membranes

PCMS arrives@ NCCC

PCMS installation

GC bakeout

GC Cal

PDMS

HF-1

TFEPPZ HF-2

Cal

HF-3

HF-4

Film C

Unit 5 shutdown

Page 10: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

10National Energy Technology Laboratory

December 2015 feed characteristics

CO2, O2 and N2 feed compositions analyzed from retentate + permeate streams

PCMS-analyzed feed composition matches well with NCCC’s

Feed dewpoint depends on outside temperature (reduced by feed chiller to prevent condensation)

Page 11: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

11National Energy Technology Laboratory

Reference membrane: PDMS

H2O(g) permeability of PDMS: Metz, SJ; van de Ven, WJC; et al.: JMS 2005. 251, 29

• Commercial polydimethylsiloxane film

• Stable performance:– ~3300 barrer CO2– CO2/N2 around 8.5– O2/N2 around 1.9– All the above numbers

agree with lit. data• Insufficient flowrate to

measure water vapor permeability– Around 16k-18k barrer

H2O – much lower than literature ref. (40k)

– 10 sccm not enough to avoid conc. polarization

Page 12: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

12National Energy Technology Laboratory

Gen 1 mixed matrix coated hollow fibers

SIFSIX-2Cui: Nugent, P; et. al.: Nature 2013. 495, 80

SIFSIX-2Cui

PN

OCH2CF3

OCH2CF3 n

poly(bistrifluoroethoxy)phosphazene(TFE-PPZ)flat sheet TFE-PPZ/SIFSIX-2Cui (not tested at PCMS)

HF-1 (TFE-PPZ/30 wt% SIFSIX-2Cui coating)high surface porosity Torlon hollow fibers

Polymer

MOF

+Fiber

Page 13: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

13National Energy Technology Laboratory

Mixed matrix coated hollow fiber membranes

• PPZ/SIFSIX mixed matrix coated hollow fiber (HF-1)– Slight decline in all gas

permeance over 22h: CO2 from ~75 GPU to ~70 GPU

– Insufficient time to determine decline significance

All hollow fibers are assumed: length = 10 cm, outer diameter = 540 µm

Page 14: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

14National Energy Technology Laboratory

Summer 2016 campaign timeline

5 6 7 8

27 28 29

July

8

24 25 26 22 23

August September

• Three membranes planned this season– Focus on medium term tests (3-4 weeks) to gain operational

experience– Whenever available, test thin film hollow fiber composite membranes– One three-week test successfully concluded on a free-standing film– Ongoing testing on membrane #2

Page 15: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

15National Energy Technology Laboratory

PDMS re-run to verify operation

• Confirmed PCMS still working after 6 months downtime

• Confirmed CO2, O2, N2results against previous run

• Higher apparent H2O permeability (25k-28k barrer) with 50 sccmfeed flowrate

• Hourly sampling frequency

Page 16: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

16National Energy Technology Laboratory

Conclusions

• We have an operational membrane testing skid at NCCC– Versatile for testing different membrane formats– Short term testing gives data well corroborated with literature values

and/or other testing equipment at NETL– Sufficient feed flowrate is required to quantify water vapor permeance

accurately• Short term membrane performance at low humidity +

contaminants consistent with performance under dry, ideal conditions

• The PCMS can be operated unattended for longer periods of time– We have completed a three-week unattended test– The skid can tolerate several process upsets (e.g. temporary loss of feed

flue gas)– Gas chromatograph maintenance imposes the biggest limitation on testing

length

Page 17: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

17National Energy Technology Laboratory

Future plan

• Finish current testing season at NCCC– Up to two additional membranes to be tested

(4 week runs)– Upgrade feed flowrate capability to measure

water vapor permeance

• Design improvements– More efficient water vapor removal to

protect GC columns– Flow components to accommodate small

multi-fiber modules

• Continue developing membranes with focus on thin film composite hollow fiber membranes

Gen 1 coated HF (tested)

Gen 2 coated HF (in development)

Page 18: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

18National Energy Technology Laboratory

Acknowledgements

NETL• Justin Anthony• Bob Lambrecht• NCCC process engineers• Caddell construction crew

• Heather Juzwa• Mark Waksmonski• Yuan Lin

NCCC

Shimadzu Corp.

• Kevin Resnik• Dave Hopkinson• John O’Connor• Jeffrey Hash• Ron Hirsh• Ray Rokicki• Bill Walker• Rocky Stoneking• Rich Valdisera• Surendar Venna• Shan Wickramanayake• Ganpat Dahe • Ali Sekizkardes• Christina Myers

Page 19: Driving Innovation Delivering Results Library/Events/2016/c02 cap review/1... · Driving Innovation ... start and walk away” operation philosophy ... – Sufficient feed flowrateis

19National Energy Technology Laboratory

This project was funded by the Department of Energy, National Energy Technology Laboratory, an agency of the United States Government, through a support contract with AECOM. Neither the United States Government nor any agency thereof, nor any of their employees, nor AECOM, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

Thank you for your attention!

This technical effort was performed in support of the National Energy Technology Laboratory’s ongoing research under the RES contract DE‐FE0004000.