www.drgem.co.kr
GXR-SD SERIESGXR-SD SERIESDigital Radiography System
High Performance and Reliability
GXR-SD Series
Vertical Wall Bucky Stand
The Optimal System for Digital SolutionThe GXR-SD Series is a diagnostic digital radiography system providing reliable high quality digital radiographic images with reduced dose. The GXR-SD DR systems provides comprehen-sive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors, reliable high-frequency x-ray generator which has worldwide reputation on excellent performance, lifetime and stability. Also user-friendly designed various tube stands, patient table and wall stand are offered for user’s choice. The GXR-SD Series DR system will improves your workflow, exam throughput and efficiency with excellent performance.
Floor-Ceiling MountedTube Stand
Floating Tabletop Table
www.drgem.co.kr
Elevating Table
Floor MountedTube Stand
Ceiling SuspendedTube Stand
GXR-SD DIGITAL RADIOGRAPHY SYSTEMHigh Performance and Reliability
ACQUIDRACQUIDR is the digital imaging system included in GXR-SD composed of a digital flat-panel detector and an imaging workstation with software. ACQUIDR provides outstanding quality diagnostic digital images with convenient interface and designed to suit a variety of x-ray rooms. The digital flat-panel detector and fully featured imaging software with excellent digital image processing meets most of needs in diagnostic digital radiographic field. Selection of an anatomi-cal study on the imaging software automatically sets up the x-ray generator’s preprogrammed exposure technique setting and post image processing for the selected study.
For Chiropractors
Rotating tray with 4336R for the Vertical Wall Bucky Stand
RemovableHigh Resolution Grid
Rotating Tray
Rotating tray with 4336R for the Patient Table
Rotating Tray
RemovableHigh Resolution Grid
Remote Diagnosis via Internet
RemoteDiagnosisSoftware
Computer
Internet
USBConnection
Server(DRGEM)Engineer
(Service Provider)Customer Support
(DRGEM)
Solution
GXR-SD
GXR-SD Series
Floating Tabletop TableModel PBT-4
LongitudinalTransverse(Lateral)
LongitudinalInherent FiltrationMax. Patient Weight
Size
MovingFD 34~44inch,
103 lpi, ratio 10:1
EM Lock, Beam sensor on/offBuzzer sound at transverse center
100–240VAC, 200VA, 50/60Hz2,200(W) x 750(D) x 660 or 720(H) mm
150kg(330lbs)
Stationary
FD 100cm, 200lpi, ratio 10:1Optional removable grid
1,000(±500)mm250(±125)mm
350mmLess than 1.2mmAl at 100kV
300kg (660lbs)2,200(W) x 750(D) x 70(H) mm
Bucky Type
Lock(Brake)Center indicationElectrical Rating
Dimension Weight
Grid
Movement
* Rotating tray for 4336R portable DR detector with enclosure.
Tabletop
Tabletop
Detector
Elevating TableModel PBT-6
LongitudinalTransverse(Lateral)
TravelSpeed
Operating
LongitudinalInherent FiltrationMax. Patient Weight
SizeMoving
FD 34~44inch,103 lpi, ratio 10:1
EM Lock, Foot switch on/off
Buzzer sound at transverse center, Auto stop at vertical center
2-story telescopic100–240VAC, 400VA, 50/60Hz
Max. 2200(W) x 810(D) x 850(H) mm260kg(573lbs)
Stationary
FD 100cm, 200lpi, ratio 10:1Optional removable grid
1,000(±500)mm250(±125)mm
300(550~850)mm,21mm/sec
Motorized movement by Foot SwitchDC-motor (Linear Actuator)
350mmLess than 1.2mmAl at 100kV
300kg(660lbs)2,200(W) x 810(D) x 45(H) mm
Bucky Type
Lock(Brake)
Center indication
Side coverElectrical Rating
DimensionWeight
Grid
Movement
* Rotating tray for 4336R portable DR detector with enclosure.
Tabletop
Tabletop
Detector
Vertical
Vertical Wall Bucky StandModel WBS
EM Lock, Switch on/offCounter Weight
24VDC, 1AMax. 1,920(H) x 740(W) x 410(D) mm
120kg(264lbs)
Vertical 1,390mm(420~1,810mm from floor to Bucky center)
Optional extended stroke
Moving
FD 40~72inch,103 lpi, ratio 10:1
Stationary
FD 150cm, 200lpi, ratio 10:1Optional removable grid
DetectorMovement
Bucky Type
Grid
Lock(Brake)Balance
Electrical RatingDimension
Weight
* Rotating tray for 4336R portable DR detector with enclosure.
Floor-Ceiling Mounted Tube StandModel TS-FC6
Longitudinal
Transverse(Lateral)
Vertical
EM Lock, Switch on/offCounter Weight
90° step, Electric or Foot push switch24VDC, 3A
2,060(H) x 1,140(D) mm180kg(397lbs)
Max. 2,500mmOptional extended stroke
220mm (Center detent)
1,330mm(430~1,760mm from floor to focus)
Optional extended stroke
Lock(Brake)Balance
Column RotationElectrical Rating
DimensionWeight
±180°(Display: ±135°)Tube RotationAngle
Tube stroke
Floor Mounted Tube StandModel TS-FM6
Longitudinal
Transverse(Lateral)
Vertical
EM Lock, Switch on/offCounter Weight
90° step, Electric or Foot push switch24VDC, 3A
2,060(H) x 1,140(D) mm240kg(529lbs)
Max. 2,100mmOptional extended stroke
220mm (Center detent)
1,330mm(430~1,760mm from floor to focus)
Optional extended stroke
Lock(Brake)Balance
Column RotationElectrical Rating
DimensionWeight
±180°(Display: ±135°)Tube RotationAngle
Tube stroke
Ceiling Suspended Tube StandModel TS-CSA
Horizontal axis
Vertical axis
LongitudinalLateralVertical
Motorized and / or Manual, Touch screen LCDLCD display
EM Lock, Switch on/offSpring
100–240VAC, 500VA, 50/60Hz190kg(419lbs)
±180° (LCD display)
-150 ~ +180°(mechanical detents at every 90°)
3,300mm2,150mm1,500mm
OperationSID Indication
Lock(Brake)Balance
Electrical RatingWeight
Tube RotationAngle
Tube stroke
* Optional vertical tube synchronization with WBS and PBT-6
www.drgem.co.kr
Options- AEC with ion-chamber
- DAP (Dose Area Product)
- Vertical tube synchronization
- Full-Spine Imaging
- Table Bucky auto tracking with tube stand(FC or FM)
- Removable grid
- Patient hand grips (Tabletop, Overhead)
CollimatorControl
Field Shape
Max. Field Size
Leakage Radiation
Max. kVp shield
Luminosity
Option
Electrical Rating
Manual or Motorized
Rectangular
More than 43x43cm(17x17inch) at 100cm SID
Less than 100mR/hr
150kV
Over 160LUX at 100cm SID
Tape measure
24VAC, 6.3A, 50/60Hz
SystemSystem Model GXR-32SD GXR-40SD GXR-52SD GXR-68SD
Generator Model
Output Rating
GXR-32
32kW
GXR-40
40kW
GXR-52
52kW
GXR-68
68kW
10 to 400mA 10 to 500mA 10 to 640mA 10 to 800mA
640mA@81kV
500mA@104kV
400mA@130kV
320mA@150kV
800mA@85kV
640mA@106kV
500mA@136kV
400mA@150kV
GXR-82SD
GXR-82
82kW
10 to 1,000mA
1,000mA@82kV
800mA@102kV
640mA@128kV
500mA@150kV
220/230VAC, 1Ф, ±10%380/400/480VAC, 3Ф, ±10%
380/400/480VAC, 3Ф, ±10%
40~150kV, 1kV step40~125kV, 1kV step
Dual Speed including Dynamic BrakeLow Speed (Optional DC Brake)
50*/60Hz, * : Outside North America
0.001 to 10 sec, 38 steps
0.1 to 500mAs (Optional higher mAs)
400mA@50kV
320mA@100kV
250mA@125kV
500mA@80kV
400mA@100kV
320mA@125kV
Line Nominal, Phase
Coefficient of Variation : kV < 0.005, Time < 0.005, mAs < 0.01
kV < ±(1%+1kV), mA < ±(3%+1mA), Time < ±(1%+0.5ms), mAs < ±(3%+0.1mAs)
Coefficient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
Reproducibility
Accuracy
Linearity
Max. Power Output
Line Frequency
kV Range
mA Range
Timer Range
mAs Range
Rotor Supply
X-ray Tube AssemblySystem Model GXR-32SD / GXR-40SD GXR-52SD / GXR-68SD GXR-82SD
Tube Model
Manufacturer
Focal Spot Size
Rating(0.1s)
Max. Anode HU
Max. kV
1.0/2.0mm
22.5/47kW
140kHU
125kV
E7239X
Toshiba
0.6/1.5mm
18/50kW
200kHU
125kV
E7242X
Toshiba
RAD-14
Varian
0.6/1.2mm
32/77kW
300kHU
150kV
E7252X
Toshiba
0.6/1.2mm
27/75kW
300kHU
150kV
RAD-21
Varian
0.6/1.2mm
36/100kW
300kHU
150kV
E7255X
Toshiba
0.6/1.2mm
40/102kW
300kHU
150kV
Imaging Workstation
CPU
Memory
Display
Storage
Monitor
Intel(R) Core i3-530 (2.93GHz, 1333MHz FSB, 4MB L2 Cache)
2GB DDR3 1333MHz SDRAM
NVIDIA Quadro FX380
500GB x 2, 7200RPM SATA HDD
23 inch Color LCD (LED Backlight, Antiglare) Display resolution: 1920 x 1080 pixels
Digital Flat Panel DetectorModel
imaging Area / Pixel Matrix
Manufacturer
Pixe Pitch / Resolution
Screen
A/D Conversion
Interface
4336R
14 x 17 inch (2,560 x 3,072)
Varian
139um (3.6 lp/mm)
CsI or DRZ+
14-bits
Gigabit Ethernet
4343R
17 x 17 inch (3,072 x 3,072)
Ⓒ 2012 DRGEM Corporation - All rights reserved.Reproduction in whole or in part is prohibited without the written consent of the copyright-holder.
Specifications and features are subject to change without notice.All changes will be in compliance with regulations governing manufacture of medical equipment.
7Fl, E-B/D Gwangmyeong Techno-Park, 60 Haan-ro, Gwangmyeong-si, Gyeonggi-do, Korea 423-795TEL : +82-2-869-8566 / FAX : +82-2-869-8567 / www.drgem.co.kr / [email protected]