dr. terauchi guttapercha removal instrument, with peek handle
TRANSCRIPT
90 deg.
Dr. Terauchi Guttapercha Removal Instrument, with PEEK handle
Ref. 8422 EGPR-L/R 30 mm, Guttapercha removal instrument, hook to LEFT and RIGHT
Ref. 8423 EGPR-U/D 30 mm, Guttapercha removal instrument, hook UP and DOWN
Ref. 8424 EGPR-L/R 18 mm, Guttapercha removal instrument, hook to LEFT and RIGHT
Ref. 8425 EGPR-U/D 18 mm, Guttapercha removal instrument, hook UP and DOWN
1
Dr. Terauchi Instrument for Guttapercha Removal &
Penetration of Calcified or Ledged Canal
0.2
mm
Diamond coating
It is used to remove a ledged canal or a calcified canal or Guttapercha filling material because of the sharp edge and its rough surface like sandpaper.
Ref. 8426 Dr. Terauchi instrument – for calcified or ledged canal # ELES
MTA PELLET FORMING BLOCK REF. 8420 AND THE CLEE DELIVERY|CARVER INSTRUMENT REF. 8421 acc. to Dr. LEE(Patent #6,203,319)
MTA Block ** new, improved version 2017 ** # 8420- New: grooves with 0.6 mm, 0.8 mm, 1.0 mm, 1.2 mm- New: diameters of the grooves are laser marked- Made from autoclavable plastic material
MTA Carver ** new, improved version 2017**# 8421- New: lightweight PEEK handle for improved balance- Carver marked with „D“ vor Delivery working end and „C“ for Carver working end- New: Working tips ENDOBLACK® coated for better visibility under microscope
3
• Instructions on how to use the MTA Pellet Forming Block. Read carefully. (Patent #6,203,319)
• For intra-canal applications such as perforation repair and apical plugs (ortho-grade application):
• Mix the MTA to the proper consistency. Avoid a mix that is too wet or too dry. If the MTA mix is too wet, the pellet will not form. If the MTA mix is too dry, it will be crumbly and unmanageable. As a general rule, the mix should have a matte finish and not a watery gloss.
• Use a spatula to bring a small amount of MTA to the block (Figure 1). Fill one half of the long groove with MTA and wipe away the MTA outside the groove with a cotton swab or with a gloved finger. The results should look like Figure 2.
• Slide an endodontic plugger, (size 9 or 10 Schilder plugger) into the groove and push out the MTA. A small pellet of MTA, shaped like the groove, should be at the tip of the instrument. The results should look like Figure 3.
• Place the pellet into the repair site and condense. Repeat step 1 through 3 as needed.
MTA PELLET FORMING BLOCK REF. 8420 AND THE CLEE DELIVERY|CARVER INSTRUMENT REF. 8421
4
• For Root-end fillings (retro-grade application):
• Prepare the canal using ultrasonic instrumentation. Dry the canal.
• Mix the MTA to the proper consistency. Avoid a mix that is too wet or too dry. If the MTA mix is too wet, the pellet will not form. If the MTA mix is too dry, it will be crumbly and unmanageable. As a general rule, the mix should have a matte finish and not a watery gloss.
• Choose the appropriate size groove to fit the root-end preparation. Start with the smallest groove if you are uncertain. Use a spatula to bring a small amount of MTA to the block (Figure 1). Place the MTA into the groove and wipe away the MTA outside the groove with a cotton swab or with a gloved finger. The results should look like Figure 4.
• Place the tip of the CLEE Delivery|Carver Instrument Ref. 8421 into the groove (Figure 5) and slide out the MTA, (the delivery end of the instrument is the end with the letter “D” on the handle grip). A small pellet of MTA, shaped like the groove, should be at the tip of the instrument. The results should look like Figure 6a und 6b.
• Insert the pellet into the root-end preparation and condense with a plugger. Add pellets and condense until the canal is completely filled. Carve away the excess MTA with the other end of the instrument (the carving end of the instrument is the end with the letter “C” on the handle grip).
MTA PELLET FORMING BLOCK REF. 8420 AND THE CLEE DELIVERY|CARVER INSTRUMENT REF. 8421
5
• Helpful hints:
• We recommend using the J.Morita blue colored mixing pad. The MTA mixture will desiccate faster on other types of mixing pads, thus decreasing working time.
• It is easier to use a small size endodontic mixing spatula when mixing and placing the MTA into the grooves.
• For root-end fillings, the canal should be sized to an Analytic p-1L plugger or larger. Most molar and bicuspid preparations will take the small size groove. Anterior teeth generally take the larger size groove.
• Avoid digging the CLEE Delivery|Carver Instrument Ref. 8421 into the plastic when sliding the MTA pellet out of the groove.
• The MTA pellet forming block is autoclavable.
• Benefits of MTA pellet-forming technique:
• Selects for the right consistency of MTA.
• MTA can be delivered to difficult areas of the tooth.
• Clean delivery of MTA. Minimizes waste.
MTA PELLET FORMING BLOCK REF. 8420 AND THE CLEE DELIVERY|CARVER INSTRUMENT REF. 8421
6
Endo explorer DG 16/N Ref. 3249 - extra thin spring steelwith TRINOVO PEEK handle, uncoated to keep flexibility
7
Instrument for removal of broken endo files, Ref. 8400- extra thin, long working “Stieglitz style” beaks for deep gripping- ratchet handle for a safe and tight power transmission from the handle to the working beaks
8
9
Original Dovgan MTA Carriers
- bendable tubes/pluggers
- dismantable for sterilization
- single spare parts available
# 3577 Dovgan MTA Carrier 0,99 mm
# 3578 Dovgan MTA Carrier 0,8 mm
# 3579 Dovgan MTA Carrier 1,6 mm
Spare parts:
# 3580 Replacement plugger/ring for Dovgan
MTA Carrier 0,99 mm
# 3581 Replacement plugger/ring for Dovgan
MTA Carrier 0,8 mm
# 3582 Replacement plugger/ring for Dovgan
MTA Carrier 1,6 mm
# 3583 Replacement tube for Dovgan
MTA Carrier 0,99 mm
# 3584 Replacement tube for Dovgan
MTA Carrier 0,8 mm
# 3585 Replacement tube for Dovgan
MTA Carrier 1,6 mm
# 3586 Replacement body for Dovgan
MTA Carrier
Mini Mouth Mirrors
Front surface - Rhodium
They fit in any regular mouth mirror handle
with simple stem thread.
#8395 10 mm dia., packing unit: 1 piece
#8396 12 mm dia., packing unit: 1 piece
#8397 14 mm dia., packing unit: 1 piece
10
Endodontic surgery retractors acc. to Dr. KIM / U PennMountable retractor tips and handle
#7571 Handle for endo retractor acc. to Dr. KIM, 115 mm
#7572 Blade for endo retractor acc. to Dr. KIM(RKP1) 125 mm
#7573 Blade for endo retractor acc. to Dr. KIM (RKP2) 125 mm
#7574 Blade for endo retractor acc. to
Dr. KIM (RKP3) 125 mm
#7575 Blade for endo retractor acc. to
Dr. KIM (RKP4) 70 mm
#7576 Blade for endo retractor acc. to
Dr. KIM (RKP1M) 95 mm
#7577 Blade for endo retractor acc. to
Dr. KIM (RKP2M) 95 mm
#7578 Blade for endo retractor acc. toDr. KIM (RKP3M) 95 mm
#7579 Replacement screw for endo retractor
11
Retractor UCLA Dr. Han # 8440
12
Mini Blades, bendable:
#3559 (S-6300, IB6300)
speer point, straight, 6/Box
#3560 (S-6400, IBSM6400)
radius edge, 12/Box
#3561 (S-6900, IB6900)
full radius and sides, 6/Box
#3566 (6961, IB6961)
round tip, straight, 6/Box
#3567 (6962, IB6962)
round tip, 25 degrees, 6/Box
• The blades are bendable to the desired angle, by means of needle holder or pliers
• Sterile and individually wrapped
• Manufacturer: Surgistar, USA
• Fit into KOHLER # 6789 Micro Blade Handle (with 7 mm slot for US blades)
13
Mini-Micro Blades, bendable:
#3562 (USM6700, IBM6700)
radius edge, narrow, 6/Box
#3563 (USM6900, IBSM6900)
full radius and sides, 6/Box
#3564 (USM6910, IBM6910)
full radius and sides, 10 degrees
6/Box
#3565 (N6900, IBN6900)
Nordland, 6/Box
• The blades are bendable to the desired angle, by means of needle holder or pliers
• Sterile and individually wrapped
• Manufacturer: Surgistar, USA
• Fit into KOHLER # 6789 Micro Blade Handle (with 7 mm slot for US blades)
14