The DP3000M modular design features a removable power
module. Replacement power modules are available on a
service-exhange basis.
Minimum downtime, simpler on-site repairs.
Local design and manufacture equates to:
Ÿ Prompt response for customer needs.
Ÿ Customer engineering to meet clients’ specific
requirements.
Ÿ Reliable communication paths between customer and
manufacturer.
Ÿ True online double conversion design for maximum
protection against power line disturbances and outages.
Ÿ Extended battery run times available.
Ÿ Micro processor controlled for maximum reliability.
Ÿ Advanced communications.
Ÿ Full static and manual bypass so that power is available
23/7.
Ÿ Available in other voltages ie 110V and 525V on request.
Choose the UPS that has a proven track-record in the
information Technology, Industrial and Mining Industries.
Proven designs based on an understanding of the power problems
prevalent in Southern Africa.
Quality installation & after-sales service
DP3000UNINTERRUPTIBLE POWER SUPPLY
2 Samantha Street, Strijdom Park, Randburg, Johannesburg, 2194
Tel: (+27) 11 886-7874 | Fax: (+27) 11 787 0178 [email protected] | www.sinetech.co.zaSinetech
Advanced Power Products
TRUE ONLINE
DOUBLE CONVERSION
DP3000UNINTERRUPTIBLE POWER SUPPLY
DP3000-UPS-19/5Ma/Ver01
Models
Nominal Power Rating at 0.8 pf
Output Parameters
Inverter Type
Output power
Output Current at rated KVA
Output Voltage (VAC)
Output Voltage Regulation
Output Voltage THD
Output Frequency
Output Frequency Regulation
Output Frequency Window
Output Voltage Dynamic Regulation
Voltage Displacement (deg)
Overload Capacity KVA (%FL)
Overload Capacity KW (%FL)
Efficiency AC-AC
Efficiency Inverter/Converter
Output Transformer
Output Protection
Input Parameters
Rectifier Type
Input Voltage to Rectifier
Input Voltage to Bypass
Input Voltage Range to Rectifier (VAC)
Input Frequency
Input Frequency Range for Rectifier
Input Current THD at nominal Voltage
Input Power Factor at nominal Voltage
Battery
Battery Type
Nominal Battery Bus (VDC)
AC ripple current in float mode
DC ripple voltage in Float mode
End of Discharge
Static Bypass
Type
Rated Current
Maintenance Bypass
Overload Capacity
Physical Parameters
Dimensions UPS (mm)
Weight UPS
Colour
Protection
Standards
Environmental
Operating Temperature
Humidity
Maximum Altitude
While every precaution has been taken to ensure accuracy of this specification, Sinetech assumes no responsibility, and disclaims all liability for damages resulting from use of
this information. Specification subject to change without notice.
DP3010 DP3015 DP3020 DP3030 DP3040 DP3050 DP3060 DP3080
10kVA 15kVA 20kVA 30kVA 40kVA 50kVA 60kVA 80kVA
High frequency IGBT DSP controlled
8kW 12kW 16kW 24kW 32kW 40kW 48kW 64kW
14A 22A 29A 43A 58A 72A 87A 116A
380/400/415 (400V standard) 3PH 4W + Neutral
+/- 1%
<2% for linear loads, <5% for 3:1 Crest factor loads
50Hz
50Hz +/- 0.02
48Hz-52Hz synch to mains
+/-5% (100% load step) Recovery to 2% within 5ms
120 deg +/-1deg
105% continuous/ 110% 10min / 125% 1min / 150% 25sec
110% continuous/ 150% 1min / 180% 25sec
90% at full load and rated input voltage
92% at full load
Standard
Electronic and Fuse
6 pulse microprocessor controlled silicon rectifier
380/400/415 (400V standard) 3PH 4W + Neutral
380/400/415 (400V standard) 3PH 4W + Neutral +/- 10%
352 to 477
50Hz
40 to 65Hz
<30% at full load standard
>0.7 at full load
VRLA (Valve Regulated Lead Acid) or Wet
360 (Float 405V) User Adjustable
<5 % of C10 Ahr rating of battery
<1
User Adjustable
Thyristor Bridge
1.5 In
Standard
200% 1Min 1000% 10ms
W560 D780 H1170 W660 D800 H1370
235kg 295kg 325kg 350kg 400kg 425kg 500kg 600kg
Anthracite Grey RAL7016
Ip21
IEC 62040-3, IEC60146-1-1, IEC 61000-4-2, EN 50091
0-40 deg Celsius, 15 to 25 degrees recommended, 0 to 35 deg continuous
0-90% non condensing
0-2000 meters without de-rating
TRUE ONLINE