Page 1: Spill Containment, Controls and Countermeasures 1

1

Spill Containment, Controls and Countermeasures

Page 2: Spill Containment, Controls and Countermeasures 1

Spill Containment, Control and Countermeasures

SPCC

Page 3: Spill Containment, Controls and Countermeasures 1

SPCC

• 40 CFR 112• Compliance Dates for all Facilities– on or before August 16, 2002

• maintain its existing SPCC Plan

• amend and implement the SPCC Plan no later than November 10, 2010After that date, plan before/up to 6 months for production

Page 4: Spill Containment, Controls and Countermeasures 1

What are the items under SPCC• Petroleum products• Animal fats• Oils – new and used

Page 5: Spill Containment, Controls and Countermeasures 1

What is counted?

• Underground storage– 42,000 gallons or

more

• Above ground storage-1,320 in containers larger than 55 gallons.

Page 6: Spill Containment, Controls and Countermeasures 1

What is excluded?

Not counted………• Anything below 55

gallons• Mobile sources• pesticide application

equipment and related mix containers.

• any oil storage container that is permanently closed.

Frequently overlooked• Hydraulic reservoirs

on fixed equipment. • Used oil containers

Page 7: Spill Containment, Controls and Countermeasures 1

Definition of Loading/UnloadingRack

• EPA finalized a definition for loading/unloading

rack which governs whether a facility is subject to§112.7(h)

• Definition of “loading/ unloading rack” is:

– based on set of characteristics generally associated

with loading/unloading rack– based on both the description in

the SPCC Guidance for Regional Inspectors and a definition suggested by industry representatives

– a slightly modified version of the definition proposed in Oct 07

Page 8: Spill Containment, Controls and Countermeasures 1

What is a loading Arm• • Loading/unloading arm is a key component of

a loading/unloading rack.• • A loading/unloading arm typically – is a movable piping assembly that may

include fixed piping or a combination of fixed and flexible piping

– has at least one swivel joint (that is, at least two articulated parts that are connected in such a way that relative movement is feasible to transfer product via top or bottom loading/unloading to a tank truck or rail car).

Page 9: Spill Containment, Controls and Countermeasures 1

9

Loading ArmsCertain loading/unloading arm configurations present at

loading racks may include a loading/unloading arm that is a combination of flexible piping (hoses) and rigid piping without a swivel joint. – In this case, a swivel joint is not present on the loading arm because flexible piping is attached directly to the rigid piping of the loading arm and the flexible hose provides the movement needed to conduct loading or unloading operations in lieu of the

Page 10: Spill Containment, Controls and Countermeasures 1

Current (1973) RegulatoryDefinition of “Navigable Waters

The term “navigable waters” of the United States means“navigable waters” as defined in section 502(7) of theFWPCA, and includes:

• (1) all navigable waters of the United States, as defined in judicialdecisions prior to the passage of the 1972 Amendments of theFederal Water Pollution Control Act, (FWPCA) (Pub. L. 92-500)also known as the Clean Water Act (CWA), and tributaries ofsuch waters as;

• (2) interstate waters;• (3) intrastate lakes, rivers, and streams which are utilized by

interstate travelers for recreational or other purposes; and• (4) intrastate lakes, rivers, and streams from which fish or

shellfishare taken and sold in interstate commerce.

Page 11: Spill Containment, Controls and Countermeasures 1

Self Certifying: who can

• "Tier I" qualified facilities have an additional option to complete and implement a streamlined, self-certified SPCC Plan template (Appendix G to the rule).

Page 12: Spill Containment, Controls and Countermeasures 1

Tier I Qualifications • 10,000 gallons or less in aggregate aboveground oil

storage capacity; and• For the 3 years prior to Plan certification, or since

becoming subject to the rule if it has operated for less than 3 years, the facility must not have had:

– A single discharge of oil to navigable waters or adjoining

shorelines exceeding 1,000 U.S. gallons, or – Two discharges of oil to navigable waters or adjoining

shorelines each exceeding 42 U.S. gallons within any 12- month period; and

• Maximum individual aboveground oil storage container capacity of 5,000 U.S. gallons.

Page 13: Spill Containment, Controls and Countermeasures 1

Tier I and Tier II: the differences• All qualified facilities that are not Tier I are “Tier II

qualified facilities.”• A Tier I owner/operator would be able to choose Tier I or Tier II status if qualifying criteria are met.• The requirements for Tier II qualified facilities remain

the same as they were when these requirements were

promulgated in December 2006.• Tier II qualified facilities are not able to use the

Appendix G template because it does not include all of the SPCC requirements that may apply for these facilities.

Page 14: Spill Containment, Controls and Countermeasures 1

14

Training is important

• Train to the plan

• Annually at least

• Quarterly drills

• Discuss drills both good and bad

Page 15: Spill Containment, Controls and Countermeasures 1

15

• http://www.youtube.com/watch?v=rKmS8VfNNgQ

Page 16: Spill Containment, Controls and Countermeasures 1

16

Questions Please

The End