Transcript

www.bucherhydraulics.com motion and progress

Germany South / AustriaBucher Hydraulics AGJosef SieberRupert Gugg Str. 51AT - 5280 BraunauTel.: +43 7722 64 715Fax: +43 7722 64 716Mobile: +49 172 867 84 [email protected]

Germany WestBucher Hydraulics AGPhilippe RooseBlumenstrasse 24D-65366 GeisenheimTel.: +49 6722 753 72Fax: +49 6722 753 61Mobile: +49 172 610 46 [email protected]

Germany NorthBucher Hydraulics AGAndreas NickelJoachim-Ringelnatz-Str. 45D-12683 BerlinTel.: +49 30 547 12377Fax: +49 30 547 12378Mobile: +49 151 152 800 [email protected]

Service Center GermanyBucher Hydraulics AGJürgen ZehrerFranz Schubert Strasse 13D-90768 FürthTel.: +49 911 72 06 45Fax: +49 911 72 06 51Mobile: +49 172 810 51 [email protected]

FinlandIng. Buero J. Teittinen KyH. Jukka TeittinenHatanpään valtatie 34 AFI-33100 TampereTel: +358 3 214 08 81Fax: +358 3 214 63 53Mobile: +358 400 637 [email protected]

United KingdomBucher Hydraulics Ltd.Colin WillUnit 9 Eastboro FieldsHemdale, NuneatonGB-Warwickshire CV11 6GLTel.: +44 2476 353 568Fax: +44 2476 353 572Mobile: +44 7721 611 [email protected]

HungaryOlmalift KFTLaszlo LukacsÜteg Utca 9/AH-1139 BudapestTel.: +36 1 339 4308Fax: +36 1 320 [email protected]

TurkeyBucher Hidrolik Sist. Tic. Ltd. Sti.Turhan AltinörsISTOÇ5. Ada No. 41TR-34550 Mahmutbey–IstanbulTel.: +90 212 659 0488 PBXFax: +90 212 659 0489Mobile: +90 532 788 [email protected]

GreeceMinos Ltd.T. Gavalas 22 Kifissou Ave.GR-10442 AthensTel.: +30 1 513 49 00Fax: +30 1 515 02 [email protected]

BulgariaALEX EA Co. Ltd.Alexander Alexandrov7, Filip Kutev Str.BG-1220 SofiaTel.: +35 929 62 22 62Fax: +35 929 69 70 [email protected]

Service Center BeneluxTechnovice (Service)Ger SnelPostbus 225NL-8250 AE DrontenTel.: +31 321 33 66 35Fax: +31 321 38 13 [email protected]

JapanBucher Hydraulics (KK)T. HiroseSakae-Cho 723-1-102Yoshikawa-ShiJP-Saitama-Ken 342-0050Tel.: +81 48 984 3713Fax: +81 48 984 [email protected]

ChinaSuzhou Bucher Hydraulics Co. Ltd.Timothy LinNo. 168, Shexing RoadLili TownCN-Wujiang City, JiangsuTel.: +86 512 6 322 1434Fax: +86 512 6 322 1033Mobile: +86 13706 250 [email protected]

IsraelMONDEO (1999) Ltd.N. Stav Bet Hapa'mon20 Hata'as Str.IL-44425 Kfar SabaTel.: +972 9 766 56 32Fax: +972 9 765 45 28Mobile: +972 52 925 [email protected]

USABucher Hydraulics, Inc.300 North Midland Ave.Saddle BrookN.J. 07663-5514Tel.: +1 201 703 8384Fax: +1 201 703 [email protected]

TaiwanBucher Hydraulics Co. Ltd.Timothy LinNo. 22 Ding Hwu 5th StreetKuasun ShiangTW-Taoyuan TaiwanTel.: +886 3 328 77 28Fax: +886 3 328 83 [email protected]

IranALMAS NEGIN LIFT CO.Mohammad Reza ZohrehvandiHighway Africa, Street PadidarSharuz Building, 3th floor, no. 10Tehran - IranTel.: +98 21 888 67 14Fax: +98 21 888 67 [email protected]

Middle East contact USA contact

Spare Parts Center GermanyBucher Hydraulics AGSusanne SieberLoferer Weg 3aD-82140 OlchingTel.: +49 8142 4870 36Fax: +49 8142 4870 [email protected]

Service Center World WideBucher Hydraulics AGIndustriestrasse 15CH-6345 NeuheimTel.: +41 41 757 03 33Fax: +41 41 757 03 [email protected]

SwitzerlandBucher Hydraulics AGIndustriestrasse 15CH-6345 NeuheimTel.: +41 41 757 03 33Fax: +41 41 757 03 [email protected]

Head Office, Elevators

European contacts

Elevator Division

Asia contacts

1

3

4

82

6

5

7

© BUCHER HYDRAULICS NEUHEIM - 300-P-9010205-E-00/10.05

Legend

1 Relevelling unit

2 Pressure switch

3 Oil level sight gauge

4 Tank heater

5 Oil level float switch

6 Cooler connections

7 Thermostat

8 Hand pump

Additional accessories on request, i.e. Softstarter

Optional accessories

Saturn b with Beringer LRV-1

Example of use

UDA 150 with control cabinet UDA 150 with assembling cabinet Machine room cabinet

Saturn b

DC

B

A

)

N

S

50100

1501600

bar

DELCON

NTA-2

M

18

17

5

2

1

4

3

5

6 7 8

9

10

19

Z

20

11122123

Z3

Z2Z1

13

14

15

16

22

20 bar / 10 °C20 bar / 30 °C20 bar / 70 °C40 bar / 10 °C40 bar / 30 °C40 bar / 70 °C

10

6

2

0

4

8

-2

-4

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

Z1

Z2

Z3

P

T

Z

We

rese

rve

the

right

of m

odifi

catio

n w

ithou

t not

ice.

/ D

etai

led

info

rmat

ion

acco

rdin

g P

rodu

ct C

atal

ogue

.

Power consumption at 15 mm²/s

Lower stopping place 0,0 mUpper stopping place 3,8 m

Dimensions and oil flow

Digital Electronic Card for Beringer Lift Control Valves LRV, LRV-A, LRV-1 and VF-LRV

compatible with analog cards ELRV-A / ELRV-1improved travel characteristicsdisplay of travel curves on PCdemand/feedback value control (SIU1) and speed control in door zone (SIU4) simultaneously possiblefault loggeradjustments by means of a miniterminal at front plateoptions for simplified and comfortable setting with Handterminal HT or Software Windelta32 (CD)

••••

•••

Functional diagram LRV-1

Travel characteristic: at 250 mm²/s, empty car(Oil HLP 46 at 10°C)

Travel characteristic: at 15 mm²/s, full load(Oil HLP 46 at 70°C)

wide range of operating temperaturereduction of power lossreduced energy coststotal travel time reduced due to short levelling distancesdown speed can be increased up to 50% without extra costs or loss of comfortinsensitive to changes in pressure and temperatureno cooling or heating necessary in many casesexcellent travel comfort

••••••••

Advantages

Travelling characteristic

The electronically controlled Lift Valve

Leve

lling

acc

urac

y (m

m)

(Diff

eren

ce fr

om fl

oor

leve

l)

mechanical valves of competitors electronic controlled LRV-1

Start-com-mand

Start-com-mand

Idle time

Motor running time

V Speed

V Speed

Idle time

Motor running time

Time

Time differenceat 15 mm²/s

Time

Open loop control (mechanical)Characteristics at temperature differences

Idle time variableAcceleration variableTravel speed variableDeceleration variableLevelling speed variableTravelling time variablePower consumption variablePower loss high

••••••••

Closed loop control (LRV-1)Characteristics at temperature differences

Idle time short and constantAcceleration constantTravel speed constantDeceleration constantLevelling speed constantTravelling time constantPower consumption constantPower loss low

••••••••

kWh in % = 70

kWh in % = 100

Levelling accuracy(Based on 20 bar / 30 °C)

The Power Unit Series

Advantages

standardized rangeoptimized filling volumereliable technology with electronically controlled Lift Valve Beringer LRV-1minimum space requiredbest heat radiationreduced noise leveleasy service and maintenanceoperating range from Standard Ele-vator up to Heavy Goods Lift

•••

•••••

Pressure relief valve (set screw)Bypass pressure set screwLowering speed adjustmentPressure relief valvePilot filterTest port, DIN 16271Pressure gaugePressure gauge shuttoff valveVentilation screwFeedback sensorMain filterFlow-rate metering systemManual emergency loweringDOWN SpoolCheck valveUP SpoolDamping jet, UPDamping jet, DOWN Pipe rupture valve RSGBall valve KHPressure switch DZ, DPHand pumpCheck valvePressure switch portPressure switch portHand pump portPump portTank portCylinder portaccessible from outside

DOWN

UP

Valve Flow [l/min.] Dyn. pressure [bar] Viscosity [cSt] Temperature [°C]min. nom. max. max. min. max. max.

LRV 175-1 15 175 250 80 20 500 70

LRV 350-1 251 350 500 80 20 500 70

LRV 700-1 401 700 1000 67 20 500 70

Technical data

Tank type max. oil volu-me [l]

max. usable oil volume [l]

LRV A B C D Motor power Pump type

Typ mm mm mm mm 50 Hz kW l/min

UDA 150 154 88 175-1 870 304 722 1132 3-20 20-240

UDA 230 228 146175-1350-1

870 354 88513401370

3-24 20-240

UD 350 330 200175-1350-1

1004 480 94514001430

6-33 40-370

UD 500 530 340175-1350-1700-1

1184 550 1115157016001700

6-47 40-500

UC 750 720 540175-1350-1700-1

1472 760 1090155015801680

6-77 40-800

UC 1000 1045 850350-1700-1

1572 820 129017801880

6-77 40-800

Beringer LRV-1 Delta Controller DELCON Saturn b

DC

B

A

)

N

S

50100

1501600

bar

DELCON

NTA-2

M

18

17

5

2

1

4

3

5

6 7 8

9

10

19

Z

20

11122123

Z3

Z2Z1

13

14

15

16

22

20 bar / 10 °C20 bar / 30 °C20 bar / 70 °C40 bar / 10 °C40 bar / 30 °C40 bar / 70 °C

10

6

2

0

4

8

-2

-4

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

Z1

Z2

Z3

P

T

Z

We

rese

rve

the

right

of m

odifi

catio

n w

ithou

t not

ice.

/ D

etai

led

info

rmat

ion

acco

rdin

g P

rodu

ct C

atal

ogue

.

Power consumption at 15 mm²/s

Lower stopping place 0,0 mUpper stopping place 3,8 m

Dimensions and oil flow

Digital Electronic Card for Beringer Lift Control Valves LRV, LRV-A, LRV-1 and VF-LRV

compatible with analog cards ELRV-A / ELRV-1improved travel characteristicsdisplay of travel curves on PCdemand/feedback value control (SIU1) and speed control in door zone (SIU4) simultaneously possiblefault loggeradjustments by means of a miniterminal at front plateoptions for simplified and comfortable setting with Handterminal HT or Software Windelta32 (CD)

••••

•••

Functional diagram LRV-1

Travel characteristic: at 250 mm²/s, empty car(Oil HLP 46 at 10°C)

Travel characteristic: at 15 mm²/s, full load(Oil HLP 46 at 70°C)

wide range of operating temperaturereduction of power lossreduced energy coststotal travel time reduced due to short levelling distancesdown speed can be increased up to 50% without extra costs or loss of comfortinsensitive to changes in pressure and temperatureno cooling or heating necessary in many casesexcellent travel comfort

••••••••

Advantages

Travelling characteristic

The electronically controlled Lift Valve

Leve

lling

acc

urac

y (m

m)

(Diff

eren

ce fr

om fl

oor

leve

l)

mechanical valves of competitors electronic controlled LRV-1

Start-com-mand

Start-com-mand

Idle time

Motor running time

V Speed

V Speed

Idle time

Motor running time

Time

Time differenceat 15 mm²/s

Time

Open loop control (mechanical)Characteristics at temperature differences

Idle time variableAcceleration variableTravel speed variableDeceleration variableLevelling speed variableTravelling time variablePower consumption variablePower loss high

••••••••

Closed loop control (LRV-1)Characteristics at temperature differences

Idle time short and constantAcceleration constantTravel speed constantDeceleration constantLevelling speed constantTravelling time constantPower consumption constantPower loss low

••••••••

kWh in % = 70

kWh in % = 100

Levelling accuracy(Based on 20 bar / 30 °C)

The Power Unit Series

Advantages

standardized rangeoptimized filling volumereliable technology with electronically controlled Lift Valve Beringer LRV-1minimum space requiredbest heat radiationreduced noise leveleasy service and maintenanceoperating range from Standard Ele-vator up to Heavy Goods Lift

•••

•••••

Pressure relief valve (set screw)Bypass pressure set screwLowering speed adjustmentPressure relief valvePilot filterTest port, DIN 16271Pressure gaugePressure gauge shuttoff valveVentilation screwFeedback sensorMain filterFlow-rate metering systemManual emergency loweringDOWN SpoolCheck valveUP SpoolDamping jet, UPDamping jet, DOWN Pipe rupture valve RSGBall valve KHPressure switch DZ, DPHand pumpCheck valvePressure switch portPressure switch portHand pump portPump portTank portCylinder portaccessible from outside

DOWN

UP

Valve Flow [l/min.] Dyn. pressure [bar] Viscosity [cSt] Temperature [°C]min. nom. max. max. min. max. max.

LRV 175-1 15 175 250 80 20 500 70

LRV 350-1 251 350 500 80 20 500 70

LRV 700-1 401 700 1000 67 20 500 70

Technical data

Tank type max. oil volu-me [l]

max. usable oil volume [l]

LRV A B C D Motor power Pump type

Typ mm mm mm mm 50 Hz kW l/min

UDA 150 154 88 175-1 870 304 722 1132 3-20 20-240

UDA 230 228 146175-1350-1

870 354 88513401370

3-24 20-240

UD 350 330 200175-1350-1

1004 480 94514001430

6-33 40-370

UD 500 530 340175-1350-1700-1

1184 550 1115157016001700

6-47 40-500

UC 750 720 540175-1350-1700-1

1472 760 1090155015801680

6-77 40-800

UC 1000 1045 850350-1700-1

1572 820 129017801880

6-77 40-800

Beringer LRV-1 Delta Controller DELCON Saturn b

DC

B

A

)

N

S

50100

1501600

bar

DELCON

NTA-2

M

18

17

5

2

1

4

3

5

6 7 8

9

10

19

Z

20

11122123

Z3

Z2Z1

13

14

15

16

22

20 bar / 10 °C20 bar / 30 °C20 bar / 70 °C40 bar / 10 °C40 bar / 30 °C40 bar / 70 °C

10

6

2

0

4

8

-2

-4

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

Z1

Z2

Z3

P

T

Z

We

rese

rve

the

right

of m

odifi

catio

n w

ithou

t not

ice.

/ D

etai

led

info

rmat

ion

acco

rdin

g P

rodu

ct C

atal

ogue

.

Power consumption at 15 mm²/s

Lower stopping place 0,0 mUpper stopping place 3,8 m

Dimensions and oil flow

Digital Electronic Card for Beringer Lift Control Valves LRV, LRV-A, LRV-1 and VF-LRV

compatible with analog cards ELRV-A / ELRV-1improved travel characteristicsdisplay of travel curves on PCdemand/feedback value control (SIU1) and speed control in door zone (SIU4) simultaneously possiblefault loggeradjustments by means of a miniterminal at front plateoptions for simplified and comfortable setting with Handterminal HT or Software Windelta32 (CD)

••••

•••

Functional diagram LRV-1

Travel characteristic: at 250 mm²/s, empty car(Oil HLP 46 at 10°C)

Travel characteristic: at 15 mm²/s, full load(Oil HLP 46 at 70°C)

wide range of operating temperaturereduction of power lossreduced energy coststotal travel time reduced due to short levelling distancesdown speed can be increased up to 50% without extra costs or loss of comfortinsensitive to changes in pressure and temperatureno cooling or heating necessary in many casesexcellent travel comfort

••••••••

Advantages

Travelling characteristic

The electronically controlled Lift Valve

Leve

lling

acc

urac

y (m

m)

(Diff

eren

ce fr

om fl

oor

leve

l)

mechanical valves of competitors electronic controlled LRV-1

Start-com-mand

Start-com-mand

Idle time

Motor running time

V Speed

V Speed

Idle time

Motor running time

Time

Time differenceat 15 mm²/s

Time

Open loop control (mechanical)Characteristics at temperature differences

Idle time variableAcceleration variableTravel speed variableDeceleration variableLevelling speed variableTravelling time variablePower consumption variablePower loss high

••••••••

Closed loop control (LRV-1)Characteristics at temperature differences

Idle time short and constantAcceleration constantTravel speed constantDeceleration constantLevelling speed constantTravelling time constantPower consumption constantPower loss low

••••••••

kWh in % = 70

kWh in % = 100

Levelling accuracy(Based on 20 bar / 30 °C)

The Power Unit Series

Advantages

standardized rangeoptimized filling volumereliable technology with electronically controlled Lift Valve Beringer LRV-1minimum space requiredbest heat radiationreduced noise leveleasy service and maintenanceoperating range from Standard Ele-vator up to Heavy Goods Lift

•••

•••••

Pressure relief valve (set screw)Bypass pressure set screwLowering speed adjustmentPressure relief valvePilot filterTest port, DIN 16271Pressure gaugePressure gauge shuttoff valveVentilation screwFeedback sensorMain filterFlow-rate metering systemManual emergency loweringDOWN SpoolCheck valveUP SpoolDamping jet, UPDamping jet, DOWN Pipe rupture valve RSGBall valve KHPressure switch DZ, DPHand pumpCheck valvePressure switch portPressure switch portHand pump portPump portTank portCylinder portaccessible from outside

DOWN

UP

Valve Flow [l/min.] Dyn. pressure [bar] Viscosity [cSt] Temperature [°C]min. nom. max. max. min. max. max.

LRV 175-1 15 175 250 80 20 500 70

LRV 350-1 251 350 500 80 20 500 70

LRV 700-1 401 700 1000 67 20 500 70

Technical data

Tank type max. oil volu-me [l]

max. usable oil volume [l]

LRV A B C D Motor power Pump type

Typ mm mm mm mm 50 Hz kW l/min

UDA 150 154 88 175-1 870 304 722 1132 3-20 20-240

UDA 230 228 146175-1350-1

870 354 88513401370

3-24 20-240

UD 350 330 200175-1350-1

1004 480 94514001430

3-33 20-370

UD 500 530 340175-1350-1700-1

1184 550 1115157016001700

3-47 20-800

UC 750 720 540175-1350-1700-1

1472 760 1090155015801680

3-77 20-800

UC 1000 1045 850350-1700-1

1572 820 129017801880

6-77 40-800

Beringer LRV-1 Delta Controller DELCON Saturn b

www.bucherhydraulics.com motion and progress

Germany South / AustriaBucher Hydraulics AGJosef SieberRupert Gugg Str. 51AT - 5280 BraunauTel.: +43 7722 64 715Fax: +43 7722 64 716Mobile: +49 172 867 84 [email protected]

Germany WestBucher Hydraulics AGPhilippe RooseBlumenstrasse 24D-65366 GeisenheimTel.: +49 6722 753 72Fax: +49 6722 753 61Mobile: +49 172 610 46 [email protected]

Germany NorthBucher Hydraulics AGAndreas NickelJoachim-Ringelnatz-Str. 45D-12683 BerlinTel.: +49 30 547 12377Fax: +49 30 547 12378Mobile: +49 151 152 800 [email protected]

Service Center GermanyBucher Hydraulics AGJürgen ZehrerFranz Schubert Strasse 13D-90768 FürthTel.: +49 911 72 06 45Fax: +49 911 72 06 51Mobile: +49 172 810 51 [email protected]

FinlandIng. Buero J. Teittinen KyH. Jukka TeittinenHatanpään valtatie 34 AFI-33100 TampereTel: +358 3 214 08 81Fax: +358 3 214 63 53Mobile: +358 400 637 [email protected]

United KingdomBucher Hydraulics Ltd.Colin WillUnit 9 Eastboro FieldsHemdale, NuneatonGB-Warwickshire CV11 6GLTel.: +44 2476 353 568Fax: +44 2476 353 572Mobile: +44 7721 611 [email protected]

HungaryOlmalift KFTLaszlo LukacsÜteg Utca 9/AH-1139 BudapestTel.: +36 1 339 4308Fax: +36 1 320 [email protected]

TurkeyBucher Hidrolik Sist. Tic. Ltd. Sti.Turhan AltinörsISTOÇ5. Ada No. 41TR-34550 Mahmutbey–IstanbulTel.: +90 212 659 0488 PBXFax: +90 212 659 0489Mobile: +90 532 788 [email protected]

GreeceMinos Ltd.T. Gavalas 22 Kifissou Ave.GR-10442 AthensTel.: +30 1 513 49 00Fax: +30 1 515 02 [email protected]

BulgariaALEX EA Co. Ltd.Alexander Alexandrov7, Filip Kutev Str.BG-1220 SofiaTel.: +35 929 62 22 62Fax: +35 929 69 70 [email protected]

Service Center BeneluxTechnovice (Service)Ger SnelPostbus 225NL-8250 AE DrontenTel.: +31 321 33 66 35Fax: +31 321 38 13 [email protected]

JapanBucher Hydraulics (KK)T. HiroseSakae-Cho 723-1-102Yoshikawa-ShiJP-Saitama-Ken 342-0050Tel.: +81 48 984 3713Fax: +81 48 984 [email protected]

ChinaSuzhou Bucher Hydraulics Co. Ltd.Timothy LinNo. 168, Shexing RoadLili TownCN-Wujiang City, JiangsuTel.: +86 512 6 322 1434Fax: +86 512 6 322 1033Mobile: +86 13706 250 [email protected]

IsraelMONDEO (1999) Ltd.N. Stav Bet Hapa'mon20 Hata'as Str.IL-44425 Kfar SabaTel.: +972 9 766 56 32Fax: +972 9 765 45 28Mobile: +972 52 925 [email protected]

USABucher Hydraulics, Inc.300 North Midland Ave.Saddle BrookN.J. 07663-5514Tel.: +1 201 703 8384Fax: +1 201 703 [email protected]

TaiwanBucher Hydraulics Co. Ltd.Timothy LinNo. 22 Ding Hwu 5th StreetKuasun ShiangTW-Taoyuan TaiwanTel.: +886 3 328 77 28Fax: +886 3 328 83 [email protected]

IranALMAS NEGIN LIFT CO.Mohammad Reza ZohrehvandiHighway Africa, Street PadidarSharuz Building, 3th floor, no. 10Tehran - IranTel.: +98 21 888 67 14Fax: +98 21 888 67 [email protected]

Middle East contact USA contact

Spare Parts Center GermanyBucher Hydraulics AGSusanne SieberLoferer Weg 3aD-82140 OlchingTel.: +49 8142 4870 36Fax: +49 8142 4870 [email protected]

Service Center World WideBucher Hydraulics AGIndustriestrasse 15CH-6345 NeuheimTel.: +41 41 757 03 33Fax: +41 41 757 03 [email protected]

SwitzerlandBucher Hydraulics AGIndustriestrasse 15CH-6345 NeuheimTel.: +41 41 757 03 33Fax: +41 41 757 03 [email protected]

Head Office, Elevators

European contacts

Elevator Division

Asia contacts

1

3

4

82

6

5

7

© BUCHER HYDRAULICS NEUHEIM - 300-P-9010205-E-00/10.05

Legend

1 Relevelling unit

2 Pressure switch

3 Oil level sight gauge

4 Tank heater

5 Oil level float switch

6 Cooler connections

7 Thermostat

8 Hand pump

Additional accessories on request, i.e. Softstarter

Optional accessories

Saturn b with Beringer LRV-1

Example of use

UDA 150 with control cabinet UDA 150 with assembling cabinet Machine room cabinet

Saturn b


Top Related