Page 2: Portable Control & Measurement Device

The PCD: Portable & user friendly

Low-priced

Versatile & multi-purposed

Measure and display results instantly

Store data for later re-evaluation

Control over environment

Customization and extension of feature-set in

HW & SW

Page 3: Portable Control & Measurement Device

Project goals• Self-learning process:– Data sheets, schematics, HW & SW, MPLab

• Assemble & HW debug

• Sensors debug and driver implementation

• Multiple devices production – 9 boards

• Boxes production

• Main menu improvement

• BOM & inventory management

Page 4: Portable Control & Measurement Device

Main Menu• PCD voltage shows battery value.

• Dcdc opens automatically when needed.

• Dcdc and all related sensors turn off when

temperature sensor is on.

• Each menu has different sensors according

to what is assembled on its board.

Page 5: Portable Control & Measurement Device

Accelerometer

A micro-machined device measuring static acceleration.Output voltage alternates according to 3 dimensional axis.

Page 6: Portable Control & Measurement Device

Pressure

A silicon sensor measuring absolute pressure.Output voltage can be converted to

pressure by:

קומה פישבך13

קומה פישבך1

Page 7: Portable Control & Measurement Device

Buzzer

An electronic audio device working by alternating on and off the signal source given by the PIC, thus creating different frequencies which give a big array of sounds.

for (b=0;b<9000;b++){}for (b=0;b<18000;b++){ if ((b%100)==0) MCU_AUX_BUZZER = !MCU_AUX_BUZZER;}for (b=0;b<9000;b++){}for (b=0;b<18000;b++){ if ((b%190)==0) MCU_AUX_BUZZER = !MCU_AUX_BUZZER;}

Page 8: Portable Control & Measurement Device

UV

A “Shotki” photodiode for UV sensing. The sensor is brought to the surface of the box in order to efficiently absorb all UV rays. Max value in full UV exposure is 3.3.

Shadow

Through window

Full sun light

Page 9: Portable Control & Measurement Device

IR

IR transmitter/receiver.Receiving function is checked using ISR due to high frequencies.

Page 10: Portable Control & Measurement Device

Magnetic

Measures the earths’ magnetic field. Nickel-iron strips change their voltage in presence of a magnetic field. Output voltage alternates according to 2 dimensional axis.

Page 11: Portable Control & Measurement Device

Optic

A CMOS optic sensor that decides on direction of movement by taking 1700 frames per second and comparing them. The sensor needs an external led and prism to work. Output voltage (“1”/”0”) needs to be processed in a FSM. 2 outputs for each direction.

Page 12: Portable Control & Measurement Device

FSM:

Optic

Page 13: Portable Control & Measurement Device

• In order to meet the nyquist condition sampling must occur every 30 microsec.

• Sampling in the main func occurs every 30 milisec.

• There is a need for a short ISR every 30 microsec of the main func.

• Entrance to ISR is made by “Timer 0” .• Only sampling inside the ISR

Optic

Page 14: Portable Control & Measurement Device

ISR must be shorter than the timer, therefore only a minimal number of actions are made inside.

• Sampling sensor output.• Comparing to last value saved in array.• Saving new value in array, only if changed.

FSM and the decision about what direction to move to are done in the main func.

void isr_timer0(void){A=SENS_MCU_MOUSE_X1;B=SENS_MCU_MOUSE_X2;C=SENS_MCU_MOUSE_Y1;D=SENS_MCU_MOUSE_Y2;current_byte = D + (C << 1) + (B << 2) +

(A << 3);if ((current_byte ^ last_byte)) {

OPT[w]= current_byte;last_byte = current_byte;w=(w+1);

}}

Optic

Page 15: Portable Control & Measurement Device

Multiple devices production• Common malfunctions:–Design mistakes–Assemble mistakes–Defective components–Short/open circuit –Borderline design–Unexpected high “Pic” resistant–Out of range “Pic” input voltages

Page 16: Portable Control & Measurement Device

Multiple devices production• Locate malfunctions:–Visual check–Voltage measure using Scope–Comparison to proper boards–Confirmation with “Data Sheet”–Resistant measurement w/o component–Disconnect (“lifting”) components (“legs”)–SW

Page 17: Portable Control & Measurement Device

Status Report8 7 6 5 4 3 2 1 0 Device No/.

Sensors

+ + + + + + + + IR

+ + + + + + + + + Temperature

+ + + + + + + + + Buzzer

+ + + + + + Pressure

+ + + + + + + + + Accelerometer

+ + + Microphone

+ + + + + + + + + SD

+ + + + UV

+ + + + + + Magnetic

+ Optic

3 batteries missing – fund alternative

Page 18: Portable Control & Measurement Device

Future improvements • Improvements and amplifier for the microphone • Optic sensor:– Add speed detection – integration to the main menu (change timer)

• Clock

• Improvement of buzzer resolution

• Case for buttons

• Additional memory

Page 19: Portable Control & Measurement Device

Future applications • GUI for PC

• IR - remote control

• IR + microphone – volume control

• Optic – digital ruler

• Optic – OCR

• Accelerometer – digital leveler

• Accelerometer – angle gauge

• UV + buzzer – high radiation indicator

Page 20: Portable Control & Measurement Device