NEW: 2022 SeriesFilter Assembly
Data Sheet PIM 2022
Features
• 316 Stainless Steel construction
• Accepts Pall 21⁄2 ˝ diameter elements with M3 seals
• Optional bypass valve
• Flows to 110 Lpm (30 gpm)
• Pressures to: 17.9 bar (260 psi)
• Port size: 3⁄4 ˝ and 1˝
Notes and SpecificationsMaximum Working Pressure: 17.9 bar (260 psi)
40° C (104° F)Design Pressure: 13.8 bar (200 psi)
150° C (302° F)Materials of Construction: 316 stainless steel Element Construction:Poly-Fine® XLD cartridges All polypropylene constructionDynalloy® cartridges Sintered 316 stainless steel
fibersDynamesh™ cartridges Woven 316 stainless steel
wire cloth
Pressure Drop InformationFigure 1. Housing pressure drop.Housing pressure drop is directly proportional to specificgravity.
Element Pressure Drop. For liquids other than water, multiply pressure drop x newviscosity in cSt x new S.G.
1
Flow Rate (gpm)
Diff
eren
tialP
ress
ure
(psi
d)
03
0405
MEDIA
GRADE 06
09
12
40
.1
.07
.05
.04
.03
.02
.01
1
.7
.5
.4
.3
.2
2 3 4 7 10 20 30 4050 70 100
0.5
0.4
0.3
0.2
0.1
0
8
6
4
2
00
0 25 50 75 100
10 20 30Flow Rate (gpm)
Flow Rate (Lpm)
Diff
eren
tialP
ress
ure
(bar
)
Diff
eren
tialP
ress
ure
(psi
d)
Note: For liquid other than water, multiply the pressure dropby the specific gravity of the fluid.
2022 series filter housing
0.3
0.25
0.3
0.15
0.1
0.05
01 2 4 5
Flow Rate (gpm)
Diff
eren
tialP
ress
ure
(psi
d)
3 6
3.0 µm
4.5 µm
10 µm
20 µm
Dynalloy/Dynamesh Series Filter Cartridges
Poly-Fine® XLD Series Filter Cartridges
© Copyright 2006, Pall Corporation. Pall, , are trademarks of Pall Corporation. ® Indicates a Pall trademark registered in the USA. is a service mark of Pall Corporation.
Ordering Information
Assembly P/N: H 2022 ++ T
Table 1 Table 2 Table 4 Table 5 Table 6 Table 7
Poly-Fine XLD Cartridge P/N:XLD - U M3
Table 3 Table 4 Table 1
Dynalloy Cartridge P/N:PSP - S M3*
Table 3 Table 4
*Note: O-ring seals must be ordered separately. Order 2 pieces p/n D10540-456 for nitrile, 2 pieces p/n D10540-457 for fluorocarbon
Dynamesh Cartridge P/N:PWC - S M3*
Table 3 Table 4
*Note: O-ring seals must be ordered separately. Order 2 pieces p/n D10540-456 for nitrile, 2 pieces p/n D10540-457 for fluorocarbon
Dimensional Drawings Table 1: Seal Options
Housing Cartridge SealsCode Code*
H N Nitrile
Z V Fluoro-carbon
* Poly-Fine XLD cartridges only
Table 3: Filter Cartridge Options
Cartridge Series Code Rating Rating Method
3 3 µm
4.5 4.5 µm
10 10 µm
20 20 µm
03 3 µm
04 4 µm
05 5 µm
06 6 µm
09 9 µm
10 12 µm
40 40 µm
70 70 µm
100 100 µm
Table 6: Differential Pressure Indicator Options*
Code Indicator
E SST visual with glasscover
B SST port plug
* Note: Other indicator options available — contact factory
Table 2: Port Options
Code Port
A12 3/4 ˝ SAE J514 straight thread
B12 3/4 ˝ NPT
A16 1˝ SAE J514 straight thread
B16 NPT
Table 4: Length Options
Housing Element LengthCode Code (in)*
K 10 10
L 20 20
* Nominal length in inches
Table 5: Bypass Valve Options
Code Valve
A 1.7 bar (25 psid)
B 3.4 bar (50 psid)
N Non- bypass
Table 7: Mounting BracketOptions
Code Option
0 none
1 Mounting bracket kit
Industrial Manufacturing25 Harbor Park DrivePort Washington, NY 11050
888.333.7255 toll free516.484.3600 phone 516.484.6247 fax
Pall Corporation has offices and plants throughout the world in locations including: Argentina,Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India, Indonesia, Ireland,Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand, Norway, Poland, PuertoRico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, UnitedKingdom, United States, and Venezuela. Distributors are located in all major industrial areasof the world.
Visit us on the Web at www.pall.com/m&e
Poly-Fine XLD 99.9% efficiency
Absolute
NominalDynamesh
Dynalloy
PALL
INLET
OU
TLET
B B
4 3/16 ˝
1 1/2 ˝
1 3/16 ˝TYP
(4) 1/4-20x1/2 ˝
2 5/8 ˝
1 5/16 ˝TYP
K=13 3/4 ˝ LG Ø3 9/16 ˝
1˝
REQUIRED SPACENEEDED FOR SHELLREMOVAL
K=12-5/8 ˝L=22-1/2 ˝
L=23 3/4 ˝ LG
7500/02 Series Spin-On Filter Assemblies
Description
Flows to 90 gpm (325 L/min) (7500); 150gpm (565 L/min) (7502) Pressures to 200 psi (14 bar) Port sizes: 1", 1-1/4" and 1-1/2" (7500) 1-1/2" and 2" (7502)
Specifications
Features
� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Gasket Seal � Spin-On Canister � Mounting Surface � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element � Optional Anti-Back Flow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level
Maximum Acceptable Working Pressure: 200 psi (14 bar) Fatigue Pressure Rating: 200 psi (14 bar) (100,000 cycles 0-200 psi) Typical Burst Pressure: 290 psi (20 bar) (Gasket extrusion) Temperature Range: Nitrile seals -20°F to 225°F (-29°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: 7500: R length–8 lbs. (3.6 kg) S length–9 lbs. (4.1 kg) 7502: R length–20 lbs. (9.1 kg) S length–22 lbs. (10 kg) Filter Element Collapse Pressure: 7500–100 psid (7 bar) 7502–100 psid (7 bar) Caution: 100 psi (7 bar) maximum for 7500/7502 Series non-bypass valve options (prevents possible filter element collapse)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
7502 series uses two 7500 series elements. Factors above are for flow through both elements in a 7502.
Ordering Information
7500 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4" N/A 0.21 0.18 0.14 0.10
8" 0.23 0.11 0.10 0.07 0.05
7502 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4" N/A 0.10 0.09 0.07 0.05
8" 0.12 0.05 0.05 0.04 0.03
Assembly P/N: H 750 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 7500 S
Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z* Fluorocarbon
*Non-standard: available for KP media only.
TABLE 2: HOUSING OPTIONS
Code Description
0 Single element
2 Double element
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT
D* Flange SAE J518c-Code 61
*7502 series only.
TABLE 4: PORT SIZE OPTIONS
Code Size Availability
16 1" 7500
20 1-1/4" 7500
24 1-1/2" 7500/7502
32 2" 7502*
*A & B port styles only.
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ* <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
*8" length only
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
R 4
S 8
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
W Non-bypass
8 25 psid with ABFV*
9 50 psid with ABFV
V Non-bypass with ABFV
* ABFV - Anti-backflow valve.
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
PM Visual indicator with thermal lockout
DM Visual indicator with no thermal lockout
LL Electrical switch (SPDT) with 6" leads
TL Electrical switch with DIN connector
ML ‘TL’ type switch with matching wiring cap
SL Electrical switch with MS receptacle
PL Same as PM but with plastic body
DL Same as DM but with plastic body
© Copyright Pall Corporation Visit us on the Web at www.pall.com
7400 Series Spin-On Filter Assemblies
Description
Flows to 35 gpm (125 L/min) Pressures to 250 psi (17 bar) Port sizes: 3/4" and 1"
Specifications
Features
� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Gasket Seal � Spin-On Canister � Optional Anti-Back Flow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level � Mounting Surface � Gray Cast Iron Head � O-Ring Seal � Ultipor® III Element
Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: 250 psi (17 bar) (60,000 cycles 0-250 psi) Typical Burst Pressure: 400 psi (28 bar) Temperature Range: Nitrile seals -20°F to 225°F (-29°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 4 lbs. (1.8 kg) S length– 4.6 lbs. (2.1 kg) Filter Element Collapse Pressure: 7400 series–100 psid (7 bar) Caution: 100 psi (7 bar) maximum for 7400 Series non-bypass valve options (prevents possible filter element collapse)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
7400 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4" 0.82 0.36 0.30 0.22 0.15
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
8" 0.43 0.19 0.15 0.12
Assembly P/N: H 7400 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Element P/N: HC 7400 S Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z* Fluorocarbon
*Non-standard: available for KP media grade in 4" length only.
TABLE 2: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT
TABLE 3: PORT SIZE OPTIONS
Code Size
12 3/4"
16 1"
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT* 25 22
* 4" length only.
TABLE 5: LENGTH OPTIONS*
Assembly Code Element Code**
R 4
S 8
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
W Non-bypass
8 25 psid with ABFV*
9 50 psid with ABFV
V Non-bypass with ABFV
* ABFV- Anti-backflow valve.
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
PM Visual indicator with thermal lockout
DM Visual indicator with no thermal lockout
LL Electrical switch (SPDT) with 6" leads
TL Electrical switch with DIN connector
ML ‘TL’ type switch with matching wiring cap
SL Electrical switch with MS receptacle
PL Same as PM but with plastic body
DL Same as DM but with plastic body
© Copyright Pall Corporation Visit us on the Web at www.pall.com
8924 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 75 gpm (284 L/min) Pressures to 400 psi (27.5 bar) Port sizes: 1" and 1¼"
Specifications
Maximum Acceptable Working Pressure: 400 psi (27.5 bar)
Fatigue Pressure Rating: 400 psi (27.5 bar) 0-2,000,000 cycles
Typical Burst Pressure: 1500 psi (103.4 bar)
Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids
Filter Element Collapse Pressure: 150 psid (10 bar)
Materials of Construction: Ductile iron head/cover Steel tube Powder coat finish
Dimensional Drawings
Performance
Pressure Drop Information
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9404 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.29 0.15 0.11 0.08 0.06
13" 0.19 0.09 0.07 0.05 0.04
16" 0.09 0.05 0.04 0.03 0.02
Assembly P/N: H 8924 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Element P/N: HC 9404 F Table4 Table5 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2: Port Style Options
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
Table 3: Port Size Options
Code Size
16 1"
20 1 1/4"
Table 4: Filter Element Options
Code �x 200 �x(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
Table 5: Length Options*
Assembly Code Element Code**
S 8
T 13
U 16
*Use code in second column for element part no. **Nominal length in inches
Table 6: Bypass Valve Options
Code Description
A 25 psid
B 50 psid
W Non bypass
Contact Information
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Table 7: Differential Pressure Device Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
S Electrical switch with MS receptacle
B Bleed plug and seal in place of indicator
3 "P" in cover, "S" in head
2 "P" in cover, "L" in head
1 Plastic plug
8300/04/10/14 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 300 gpm (1135 L/min) Pressures to 400 psi (28 bar) Port sizes: 1-1/2", 2 and 2-1/2" With Dual Manifold: Flows to 600 gpm (2270 L/min) Port Size: 3"
Specifications
Features
� T-Handle Easy Service Cover � Bleed Port Plug � O-Ring Seals � Optional Differential Pressure Devices � Anodized Aluminum Alloy-Head, Tube and Cover � Fill Port � Full Flow Fast Response Bypass Valves � Ultipor® III Element � Drain Port and Plug
Maximum Acceptable Working Pressure: 400 psi (28 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 330 psi (23 bar) Typical Burst Pressure: 2100 psi (145 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: U length– 45 lbs. (20.5 kg) X length– 92 lbs. (42 kg) Filter Element Collapse Pressure: 8300/04/14–150 psid (10 bar) 8310–100 psid (7 bar) Caution: 120 psi (8 bar) maximum for 8300/04/14 Series 80 psi (5.5 bar) maximum for 8310 Series non-bypass valve options (prevents possible filter element collapse).
Dimensional Drawings
Performance
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.
8300 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
16" 0.078 0.034 0.028 0.021 0.014
39" 0.039 0.015 0.012 0.009 0.006
8304 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
16" 0.101 0.049 0.041 0.031 0.022
39" 0.038 0.018 0.015 0.012 0.008
8310/14 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
16" 0.089 0.047 0.040 0.031 0.022
39" 0.034 0.018 0.015 0.012 0.008
Assembly P/N: H 83 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 83 F Table2 Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Option
00 Standard capacity
04 Coreless, standard capacity
10 High capacity
14 Coreless, high capacity
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
D Flange SAE J518c-Code 61
TABLE 4: PORT SIZE OPTIONS
Code Size Style Availability
24 1-1/2" A, D
32 2" A, D
40 2-1/2" D
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
U 16
X 39
* Use Code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
Y Non-bypass with 16 psid indicator
N Non-bypass with 35 psid indicator
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
Dual Manifold P/N: H 8300-SP2A3 Table1 Mounting Bracket P/N: 1129210
© Copyright Pall Corporation Visit us on the Web at www.pall.com
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
2 'P' and 'L'
3 'P' and 'S'
Electrical indicators in base only.
8110 Series Filter Assemblies
Description
Flows to 40 gpm (145 L/min) Pressures to 600 psi (41 bar) Port sizes: 3/4" and 1"
Specifications
Features
� Optional Differential Pressure Devices � Gray Cast Iron Head � Painted External Finish � Drawn Steel Bowl � High Strength Fatigue Rated Housing � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element � Optional Drain Port (Not Shown)
Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: 600 psi (41 bar) (2,000,000 cycles to 600 psi) Typical Burst Pressure: 2400 psi (165 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 9 lbs. (4.1 kg) S length– 10 lbs. (4.6 kg) T length– 11 lbs. (5 kg) Filter Element Collapse Pressure: 9100–290 psid (20 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9100 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4" 1.01 0.44 0.36 0.27 0.19
8" 0.53 0.25 0.21 0.16 0.11
13" 0.32 0.14 0.11 0.09 0.06
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
Assembly P/N: H 8110 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 9100 F Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
TABLE 3: PORT SIZE OPTIONS
Code Size
12 3/4"
16 1"
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 5: LENGTH OPTIONS*
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Assembly Code Element Code**
R 4
S 8
T 13
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
A 25 psid ± 5
B 50 psid ± 5
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
TABLE 8: OPTIONAL DRAIN PORTS
Code Description
Omit No drain
6 1/4" SAE drain port and plug
8600/04/06 Series Rotolok Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 40 gpm (145 L/min) Pressures to 600 psi (41 bar) Port sizes: 3/4" and 1"
Specifications
Features
� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: 600 psi (41 bar) (2,000,000 cycles to 600 psi) Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 8 lbs. (3.6 kg) S length– 9 lbs. (4.1 kg) T length- 11 lbs. (5 kg) Filter Element Collapse Pressure: 9600–290 psid (20 bar) 9604–150 psid (10 bar) 9606–600 psid (207 bar) Caution: 120 psi (8 bar) maximum for 8600 Series non-bypass valve options (prevents possible filter element collapse).
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9600/9604* Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4" 0.81 0.36 0.29 0.22 0.15
8" 0.46 0.20 0.17 0.12 0.09
13" 0.27 0.12 0.07 0.07 0.05
*9604 not available in 4" length.
9606 Series Element P factor (psid/gpm)
Length DS
4" 0.17
8" 0.09
13" 0.05
Assembly P/N: H 860 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 960 F Table2 Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
CODE OPTION
0 Standard
4 Coreless
6* High collapse
* 8606 is available with non-bypass valve options and ‘DS’ filter media only.
TABLE 3: PORT STYLE OPTIONS
CODE PORT STYLE
A SAE J514 straight thread
B NPT tapered pipe thread
TABLE 4: PORT SIZE OPTIONS
CODE SIZE
12 3/4"
16 1"
TABLE 5: FILTER ELEMENT OPTIONS
Code ßX 200 ßx(c) = 1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DS* 12 10
* 8606 only.
© Copyright Pall Corporation Visit us on the Web at www.pall.com
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
R*** 4
S 8
T 13
* Use code in second column for element part no. ** Nominal length in inches. ***Not available for 8604 series/9604 element.
TABLE 7: BYPASS VALVE OPTIONS
CODE DESCRIPTION
A 25 psid
B 50 psid
W* Non-bypass
8 25 psid with ABFV**
9 50 psid with ABFV**
V* Non-bypass with ABFV**
* Not available for 8604. ** ABFV– Anti-backflow valve.
TABLE 8: Differential Pressure Device Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual /electrical with DIN connector
B Plug in place of indicator
2804 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 45 gpm (170 L/min) Pressures to 600 psi (41.4 bar) Port size 1"
Specifications
Maximum Acceptable Working Pressure: 600 psi (41.4 bar) Fatigue Pressure Rating: 400 psi (27.5 bar) (106 cycles per NFPA T2.6.1-1991) Typical Burst Pressure: 2000 psi (140 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) Filter Element Collapse Pressure: 150 psid (10 bar) Materials of Construction: Cast Aluminum Head/Bowl Fluid Compatibility: Compatible with petroleum oils. Not recommended for use with water based fluids. Fluorocarbon seals are required for industrial phosphate esters, diesters and specified synthetics.
Dimensional Drawings
Performance
Pressure Drop Information
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cST), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9104 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.53 0.25 0.21 0.16 0.11
Assembly P/N: H 2804 A 16 S Table1 Table2 Table3 Table4
Element P/N: HC 9104 F 8 Table2
Table1
Contact Information
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: FILTER ELEMENT OPTIONS
Code �x 200 �x(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 3: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
W Non bypass
TABLE 4: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)
© Copyright Pall Corporation Visit us on the Web at www.pall.com
8200/04/10/14 Series Rotolok Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 110 gpm (400 L/min) Pressures to 600 psi (41 bar) Port sizes: 1", 1-1/4" and 1-1/2"
Specifications
Features
� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: 600 psi (41 bar) 2,000,000 cycles Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 17 lbs. (7.75 kg) T length– 20 lbs. (9.1 kg) U length– 23 lbs. (10.5 kg) Filter Element Collapse Pressure: 8200–150 psid (10 bar) 9604–150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
8200/9604 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.46 0.20 0.17 0.12 0.09
13" O.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
Assembly P/N: H 82 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 8200 (8200/10 Housing) F Table5 Table6 Table1
HC 9604 (8204/14 Housing) F Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
* 'L' = L head 'T' = T head
TABLE 2: ELEMENT OPTIONS
Code Option*
00 ‘L’ (standard element)
04 ‘L’ (coreless element)
10 ‘T’ (standard element)
14 ‘T’ (coreless element)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
D Flange SAE J518c–Code 61
TABLE 4: PORT SIZE OPTIONS
Code Size Style Availability
16 1" A, B
20 1-1/4" A,B,D
24 1-1/2" A,B,D
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
8 25 psid with ABFV*
9 50 psid with ABFV*
* ABVF-anti-backflow valve available with 8214 model only.
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
1 Machined part with plastic shipping plug
TABLE 9: EJECTOR SPRING OPTIONS
Code Description
N No ejector spring
S Ejector spring
© Copyright Pall Corporation Visit us on the Web at www.pall.com
8800/10 Series Rotolok Filter Assemblies
Description
Flows to 120 gpm, 454 L/min Pressures to 600 psi (41 bar) Port sizes: 1-1/2" and 2"
Specifications
Features
� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 600 psi (41 bar) Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 23 lbs. (10.5 kg) T length– 25 lbs. (11.4 kg) U length– 27 lbs. (12.3 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psid (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse).
Dimensional Drawings
Performance
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
8800 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.37 0.17 0.14 0.10 0.07
13" 0.23 0.10 0.08 0.06 0.04
16" 0.17 0.08 0.06 0.05 0.03
Assembly P/N: H 88 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10
Element P/N: HC 8800 F Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2: Head Options
Code Head Option
00 'L' Head
10 'T' Head
Table 3: Port Style Options
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
D Flange SAE J518c-code 61
Table 4: Port Size Options
Code Size
24 1-1/2"
32 2"
Table 5: Filter Element Options
Code ßx 200 ßx(c) = 1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
Table 6: Length Options*
Assembly Code Element Code**
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
Table 7: Bypass Valve Options
Code Description
A 25 psid
B 50 psid
W* Non-bypass
8* 25 psid with ABFV
9* 50 psid with ABFV
V* Non-bypass with ABFV
* ABFV- Anti-backflow valve, available for 'T' head units only: 8810.
Table 8: Differential Pressure Device Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
Table 9: Auxiliary Ports
Code Auxiliary Port
N Unmachined
B Both† sides
R* Right only†
L* Left only†
© Copyright Pall Corporation Visit us on the Web at www.pall.com
* Special order-contact factory. † Shipping plugs provided only.
Table 10: Ejector Spring Options
Code Description
N No ejector spring
S Ejector spring
8900/04/10/14 Series Rotolok Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 200 gpm (755 L/min) Pressures to 600 psi (41 bar) Port sizes: 2" and 2-1/2"
Specifications
Features
� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 600 psi (41 bar) Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 26 lbs. (12 kg) T length– 28 lbs. (13 kg) U length– 30 lbs. (14 kg) Filter Element Collapse Pressure: 150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
8900 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.30 0.14 0.12 0.09 0.06
13" 0.19 0.09 0.07 0.05 0.04
16" 0.14 0.07 0.05 0.04 0.03
8904 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.36 0.17 0.14 0.10 0.07
13" 0.21 0.10 0.08 0.06 0.04
16" 0.15 0.07 0.06 0.04 0.03
Assembly P/N: H 89 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10
Element P/N: HC 8900 (8900/10 Housing) F HC 8904 (8904/14 Housing) Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2: Element/Head Options
Code Option*
00 'L' (standard element)
04 'L' (coreless element)
10 'T' (standard element)
14 'T' (coreless element)
"L" = L Head. "T" = T Head.
Table 3: Port Style Options
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
D Flange SAE J518c-code 61
Table 4: Port Size Options
Code Size
32 2"
40* 2-1/2"
* D ports only.
Table 5: Filter Element Options
Code ßx 200 ßx(c) = 1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
Table 6: Length Options*
Assembly Code Element Code**
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
Table 7: Bypass Valve Options
Code Description
A 25 psid
B 50 psid
© Copyright Pall Corporation
W* Non-bypass
8* 25 psid with ABFV
9* 50 psid with ABFV
V* Non-bypass with ABFV
* ABFV - Anti-backflow valve, available for 'T' head units only: 8910/14.
Table 8: Differential Pressure Device Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
Table 9: Auxiliary Ports
Code Auxiliary Ports
N Unmachined
B Both† sides
R* Right only†
L* Left only†
* Special order-contact factory. † Shipping plugs provided only.
Table 10: Ejector Spring Options
Code Description
N No ejector spring
S Ejector spring
Visit us on the Web at www.pall.com
9650/51/54 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 85 gpm (309 L/min) Pressures to 2000 psi (140 bar) Port sizes: 1" and 1-1/4"
Specifications
Features
� Optional Differential Pressure Devices � Ductile Iron Head � Ductile Iron Cover � Steel Tube � Ultipor® III Element � Full Flow Fast Response Bypass Valve
Maximum Acceptable Working Pressure: 2000 psi (140 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 2000 psi (140 bar) 1500 psi (103 bar) with K ports Typical Burst Pressure: 10,000 psi (690 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 24 lbs. (11 kg) U length– 35 lbs. (16 kg) Filter Element Collapse Pressure: 9604–150 psid (10 bar) 9650–290 psid (20 bar) 9651– 3000 psid (207 bar) Materials of Construction: Ductile iron head and cover steel tube
DImensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9650/9604 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.46 0.20 0.17 0.12 0.09
16" 0.20 0.09 0.07 0.05 0.04
9651 Series Element P factor (psid/gpm)
Length DP DT
8" 0.52 0.12
16" 0.25 0.07
Assembly P/N: H 965 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 96 F Table2 Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ASSEMBLY OPTIONS
Housing Code Element Code Option
0 50 Standard element
1 51 High collapse element
4 04 Coreless element
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
K Manifold mount
TABLE 4: PORT SIZE OPTIONS
Code Size Style Availability
16 1" A, B
20 1-1/4" A,B,K
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP 3 5
DT 17 15
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
U 16
*Use code in second column for element part no. **Nominal length in inches.
© Copyright Pall Corporation Visit us on the Web at www.pall.com
TABLE 7: BYPASS VALVE OPTIONS
Code Description
B 50 psid (9650, 9654)
W Non-bypass (9651 only)
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
9020/21/24 Series Filter Assemblies
Description
Featuring Coreless Element Technology
Flows to 20 gpm (75 L/min) Pressures to 3000 psi (207 bar) Port size: 3/4"
Specifications
Features
� Full Flow Fast Response Bypass Valve � Forged Aluminum Alloy Bowl (Anodized) � Optional Differential Pressure Devices � Extruded Aluminum Alloy Head (Anodized) � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 3000 psi (207 bar)
Fatigue Pressure Rating: (NFPA/T2.6 1 -1974 category 2/90) R length-1800 psi (124 bar) S length-1500 psi (103 bar)
Typical Burst Pressure: 15,000 psi (1035 bar)
Temperature Range: Nitrile seals-45°F to 225°F (-43°C to 107°C) Fluorocarbon seals-20°F to 250°F (-27°C to 121°C) 140°F (60°C) maximum in HWCF or water-glycol fluids
Dry Weights: R length-3.7 lbs. (1.7 kg) S length-5 lbs. (2.3 kg)
Filter Element Collapse Pressure: 9020-290 psid (20 bar) 9021-3000 psid (207 bar) 9024-150 psid (10 bar)
Dimensional Drawings
Performance
Pressure Drop Information
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9020 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4" 1.90 0.82 0.54 0.35 0.21
8" 0.96 0.41 0.27 0.18 0.11
9021 Series Element P factor (psid/gpm)
Length DP DT
4" 2.71 0.68
8" 1.35 0.34
9024 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 1.12 0.48 0.31 0.21 0.13
Assembly P/N: H 902 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 902 F Table2 Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2: Element Options
Code Rating
0 290 psid (standard)
1 3000 psid (high collapse)
4 150 psid (coreless)
Table 3: Port Style Options
Code Port Style
A SAE J514 straight thread
L Manifold side mount*
K Manifold mount
*Contact factory for drawings.
Table 4: Port Size Options
Code Size
12 3/4"
TABLE 5: FILTER ELEMENT OPTIONS
CODE ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*9021 series only.
Table 6: Length Options*
Assembly Code Element Code**
R*** 4
S 8
*Use code in second column for element part no. **Nominal length in inches ***Not available for 9024 series
Table 7: Bypass Valve Options
Contact Information
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Code Description
B 50 psid-9020/9024 only
W Non bypass 9021 only
Table 8: Differential Pressure Device Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
9720/24 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 125 gpm (475 L/min) Pressures to 4500 psi (310 bar) Port size: 1-1/2"
Specifications
Features
� Bleed Valve � Extra Long Threads � Full Flow Fast Response Bypass Valve � Ductile Head and Cap � O-Ring Seals � Heavy Wall Thickness Steel Tube � Ultipor® III Element � Optional Differential Pressure Devices � Drain Port and Plug � Flat Mounting Pad
Maximum Acceptable Working Pressure: 4500 psi (310 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3000 psi (207 bar) Typical Burst Pressure: 15,000 psi (1035 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: 1-high 61 lbs. (27.8 kg) 2-high 81 lbs. (37 kg) 3-high 101 lbs. (46 kg) Filter Element Collapse Pressure: 9700–290 psid (20 bar) 8904–150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9700 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
Ordering Information
Add a "1" suffix to specify a single length element for housing length option "2" or "3". Omit to specify multiple, single-length stacked elements. Note: Choose from the options in the following tables to compile the specific Product Number.
9" 0.26 0.12 0.10 0.08 0.05
18" 0.12 0.06 0.05 0.04 0.03
27" 0.08 0.04 0.03 0.02 0.02
8904 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.36 0.17 0.14 0.10 0.07
16" 0.15 0.07 0.06 0.04 0.03
26" 0.10 0.04 0.04 0.03 0.02
Assembly P/N: H 972 24 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Element P/N: HC 9720 (9720 Housing) F 8904 (9724 Housing) Table4 Table5 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Rating
0 290 psid (standard)
4 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
D Flange SAE J518c-Code 61
K Manifold mount
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
Table 5: Length Options*
Assembly Code Element Code**
1 9 (9720)
2 18 (9720)
3 27 (9720)
S 8 (9724)
U 16 (9724)
V 26 (9724)
* Use code in second column for element part no. ** Nominal length in inches. To stack 9" elements use Pall P/N HBS630-ID5 (reusable).
Table 6: Bypass Valve Options
Code Description
B 50 psid
C 50 psid bypass with reverse flow
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
© Copyright Pall Corporation Visit us on the Web at www.pall.com
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
9850/51/54 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 35 gpm (125 L/min) Pressures to 4061 psi (280 bar) Port sizes: 3/4" and 1"
Specifications
Features
� Optional Differential Pressure Devices � Ductile Iron Head � Forged Steel Bowl � Optional Drain Port and Plug � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 4061 psi (280 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3500 psi (241 bar) Typical Burst Pressure: 18,000 psi (1240 bar) Temperature Range: Nitrile seals -45°F to 225°F(-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 9.7 lbs. (4.4 kg) S length– 12.1 lbs. (5.5 kg) T length– 15.2 lbs. (6.9 kg) Filter Element Collapse Pressure: 9800– 290 psid (20 bar) 9801– 3000 psid (207 bar) 9804-150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9800/9804 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
*9800 only
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
4" * 1.83 0.72 0.56 0.40 0.26
8" 0.95 0.37 0.29 0.21 0.13
13" 0.58 0.23 0.18 0.13 0.08
9801 Series Element P factor (psid/gpm)
Length DP DT
4" 1.82 0.84
8" 0.90 0.39
13" 0.56 0.17
Assembly P/N: H 985 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10
Element P/N: HC 980 F Table2 Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Rating
0 290 psid (standard)
1 3000 psid (high collapse)
4 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
TABLE 4: PORT SIZE OPTIONS
Code Size Port Style
12 3/4" A
16 1" A, B
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*9851 only.
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
R*** 4
S 8
T 13
* Use code in second column for element part no. ** Nominal length in inches. *** 9850/51 only.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
B 50 psid- 9850/54 only
W Non-bypass- 9851 only
TABLE 8: DIFFERENTIAL PRESSURE DEVICE
© Copyright Pall Corporation Visit us on the Web at www.pall.com
OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
TABLE 9: SPECIAL OPTIONS
Code Description
L Indicator location (left or right when facing inlet port)
R Left is standard
TABLE 10: DRAIN PORT OPTIONS
Code Description
Omit No drain port
P Drain port
9800/01/04 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 55 gpm (200 L/min) Pressures to 6000 psi (414 bar) Port sizes: 3/4" and 1"
Specifications
Features
� Ductile Iron Head � O-Ring Seals � Forged Steel Bowl � Drain Port and Plug � Optional Differential Pressure Devices � Bleed Port and Plug � Full Flow Fast Response Bypass Valve � Ultipor® III Element
Maximum Acceptable Working Pressure: 6000 psi (414 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3500 psi (241 bar) Typical Burst Pressure: 20,000 psi (1380 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 9.7 lbs. (4.4 kg) S length– 12.4 lbs. (5.65 kg) T length– 15.7 lbs. (7.16 kg) Filter Element Collapse Pressure: 9800– 290 psid (20 bar) 9801– 3000 psid (207 bar) 9804– 150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9800/9804 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4"* 1.83 0.72 0.56 0.40 0.26
8" 0.95 0.37 0.29 0.21 0.13
13" 0.58 0.23 0.18 0.13 0.08
*9800 only.
9801 Series Element P factor (psid/gpm)
Length DP DT
4" 1.82 0.84
8" 0.90 0.39
13" 0.56 0.17
Assembly P/N: H 980 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 980 F Table2 Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Rating
0 290 psid (standard)
1 3000 psid (high collapse)
4 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT tapered pipe thread
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
K Manifold mount
Table 4: Port Size Options
Code Size Port Style
12 3/4" A
16 1" A,B,D,E,K
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*9801 only.
Table 6: Length Options*
Assembly Code Element Code**
R*** 4
S 8
T 13
* Use Code in second column for element part no. ** Nominal length in inches. ***9800/01 series only.
Table 7: Bypass Valve Options
Code Description
B 50 psid-9800/04 only
W Non-bypass- 9801 only
C 50 psid bypass with reverse flow (9800 only)
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
TABLE 9: MOUNTING BRACKET OPTIONS
Code Description
1 1 mounting bracket
2 2 mounting brackets
- No mounting brackets
© Copyright Pall Corporation Visit us on the Web at www.pall.com
9660/61/64 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 150 gpm (565 L/min) Pressures to 6000 psi (414 bar) Port sizes: 1", 1-1/4" and 1-1/2"
Specifications
Features
� Bleed Port and Plug � Multiple Port Options � Ductile Iron Head � Forged Steel Bowl � Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element � Drain Port and Plug
Maximum Acceptable Working Pressure: 6000 psi (414 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3000 psi (207 bar) Typical Burst Pressure: 20,000 psi (1380 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 22 lbs. (10 kg) S length– 27 lbs. (12.3 kg) T length– 33 lbs. (15 kg) U length– 44 lbs. (20 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 9604– 150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9600/9604 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4"* 0.81 0.36 0.29 0.22 0.15
8" 0.46 0.20 0.17 0.12 0.09
13" 0.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
* 9600 only.
9601 Series Element P factor (psid/gpm)
Length DP DT
4" 1.04 0.25
8" 0.52 0.12
13" 0.32 0.08
16" 0.25 0.07
Assembly P/N: H 966 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10
Element P/N: HC 960 F Table2 Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Rating
0 290 psid (standard)
1 3000 psid (high collapse)
4 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
K Manifold mount (9660/61 only)
Table 4: Port Size Options
Code Size Style Availability
16 1" A,D,E
20 1-1/4" A,D,E
24 1-1/2" A,B,D,K
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*9661 only.
Table 6: Length Options*
Assembly Code Element Code**
R*** 4
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches. *** Not available for 9664.
Table 7: Bypass Valve Options
Code Description
B 50 psid-9660/64 only
C 50 psid bypass with reverse flow (9660/64 only)
W Non-bypass- 9661 only
K Non-bypass with reverse flow-9661 only
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
TABLE 9: MOUNTING BRACKET OPTIONS
Code Description
1 1 mounting bracket
2 2 mounting brackets
- No mounting brackets
TABLE 10: SPECIAL OPTIONS
Code Description
Y411* Heavy duty ‘B’,‘C’ or ‘K’ valve for highly cyclic applications
Y151 3/4" mounting bolt holes for ‘K’ head (1/2" bolt holes standard)
* Not available for 9664
© Copyright Pall Corporation Visit us on the Web at www.pall.com
9900/01/04 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 250 gpm (910 L/min) Pressures to 6000 psi (414 bar) Port sizes: 1-1/2" and 2"
Specifications
Features
� Bleed Port and Plug � Multiple Port Options � Steel Tube � Ductile Iron Head � Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element
Maximum Acceptable Working Pressure: 6000 psi (414 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3000 psi (207 bar) Typical Burst Pressure: 15,000 psi (1035 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: T length– 80 lbs. (36.5 kg) V length– 108 lbs. (49.2 kg) X length– 134 lbs. (61.1 kg) Filter Element Collapse Pressure: 9400– 290 psid (20 bar) 9901– 3000 psid (207 bar) 9404– 150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9400/9404 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
13" 0.19 0.09 0.07 0.05 0.04
26" 0.09 0.05 0.04 0.03 0.02
39" 0.06 0.03 0.02 0.02 0.01
9901 Series Element P factor (psid/gpm)
Length DP DT
13" 0.19 0.06
26" 0.10 0.03
39" 0.06 0.02
Assembly P/N: H 990 Note: For heavy duty valve (B,C,or K option) add Y128 to end of part number Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC F Table2 Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Element Code Rating
0 9400 290 psid (standard)
1 9901 3000 psid (high collapse)
4 9404 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
TABLE 4: PORT SIZE OPTIONS
Code Size
24 1-1/2"
32 2"
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*9901 only.
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
T 13
V 26
X 39
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
B 50 psid- 9900/04 only
© Copyright Pall Corporation Visit us on the Web at www.pall.com
C 50 psid bypass with Reverse Flow-9900/04 only
W Non-bypass-9901 only
K Non-bypass with reverse flow-9901 only
N No element no flow- valve 9901 only
Valve options W,K,N require use of 3000 psid collapse element (series code ending in ‘l’).
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 'P' and 'L'
3 'P' and 'S'
4510/11/14 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 35 gpm (130L/min) Pressures to 6500 psi (450 bar) Port sizes: 3/4" and 1"
Specifications
Features
� Optional Differential Pressure Devices � Patented Sealing Interface - Positive sealing with standard O-rings � Forged Steel Bowl � Ductile Iron Head � Full Flow Fast Response Bypass Valve � Sampling or Bleed Port � Ultipor® III Element � Optional ¼" Drain Port
Maximum Acceptable Working Pressure: 6500 psi (450 bar)
Fatigue Pressure Rating: (NFPA/T2.6.1-1991 category B/90) 5800 psi (400 bar)-Stainless steel indicators required above 3000 psi (207 bar) RFP
Typical Burst Pressure: 23,000 psi (1600 bar)
Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids
Dry Weights: R length - 15 lbs. (6.8 kg) S length - 18 lbs. (8.2 kg)
Filter Element Collapse Pressure: 9800-290 psid (20 bar) 9801-3000 psid (207 bar) 9804-150 psid (10 bar)
Dimensional Drawings
Performance
Pressure Drop Information
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cST), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9800/9804 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
4"* 1.83 0.72 0.56 0.40 0.26
8" 0.95 0.37 0.29 0.21 0.13 *9800 series only.
9801 Series Element P factor (psid/gpm)
Length DP
4" 1.82
8" 0.90
Assembly P/N: H 451 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 980 F Table2 Table5
Table6
Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Rating
0 290 psid (standard)
1 3000 psid (high collapse)
4 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
TABLE 4: PORT SIZE OPTIONS
Code Size
12 3/4"
16 1"
TABLE 5: FILTER ELEMENT OPTIONS
Code �x 200 �x(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*4511 ONLY. *Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000 psi, stainless steel indicators are necessary. Designate with an 'H' in model Code (e.g., PH, LH, etc.).
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
R*** 4
Contact Information
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)
© Copyright Pall Corporation Visit us on the Web at www.pall.com
S 8
*Use Code in second column for element part no. **Nominal length in inches. ***Not available for 4514.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
B 50 psid - 4510/14 only
C 50 psid bypass with reverse flow-4510 only
W Non-bypass - 4511 only
K Non-bypass with reverse flow - 4511 only
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
2 'P' and 'L'
3 'P' and 'S'
4610/11/14 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 70 gpm (265 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1" and 1-1/4"
Specifications
Features
� Optional Differential Pressure Devices � Patented Sealing Interface - Positive sealing with standard O-rings � Forged Steel Bowl � Ductile Iron Head � Full Flow Fast Response Bypass Valve � Sampling or Bleed Port � Ultipor® III Element � Optional ¼" Drain Port
Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1991 category B/90) 5800 psi (400 bar) Stainless steel indicators required above 3000 psi (207 bar) RFP Typical Burst Pressure: 23,000 psi (1600 bar) Filter Element Collapse Pressure: 290 psid (20 bar) minimum per ISO 2941 Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 33 lbs. (15 kg) T length– 39 lbs. (17.7 kg) Filter Element Collapse Pressure: 9100–290 psid (20 bar) 9101–3000 psid (207 bar) 9104–150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9100/9104 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.53 0.25 0.21 0.16 0.11
13" 0.32 0.14 0.11 0.09 0.06
9101 Series Element P factor (psid/gpm)
Length DP DT
8" 0.55 0.23
13" 0.34 0.16
Assembly P/N: H 461 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 910 F Table2 Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Code Rating
0 290 psid (standard)
1 3000 psid (high collapse)
4 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
TABLE 4: PORT SIZE OPTIONS
Code Size
16 1"
20 1-1/4"
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*4611 only *Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model Code (e.g., PH, DH, etc.).
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
T 13
* Use Code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
B 50 psid- 4610/14 only
© Copyright Pall Corporation Visit us on the Web at www.pall.com
C 50 psid bypass with reverse flow-4610 only
W Non-bypass- 4611 only
K Non-bypass with reverse flow-4611 only
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
4710/11/14 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 130 gpm (490 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1-1/4" and 1-1/2"
Specifications
Features
� Optional Differential Pressure Devices � Patented Sealing Interface - Positive sealing with standard O-rings � Forged Steel Bowl � Ductile Iron Head � Full Flow Fast Response Bypass Valve � Sampling or Bleed Port � Ultipor® III Element � Optional ¼" Drain Port
Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1991 category B/90) 5800 psi (400 bar) Stainless steel indicators required above 3000 psi (207 bar) RFP Typical Burst Pressure: 23,000 psi (1600 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: T length- 54 lbs. (24.5 kg) U length- 60 lbs. (27 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 4704– 150 psid (10 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9600/4704 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
13" 0.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
9601 Series Element P factor (psid/gpm)
Length DP DT
13" 0.32 0.08
16" 0.25 0.07
Assembly P/N: H 471 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC F Table2 Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Assembly Code Element Code Rating
0 9600 290 psid (standard)
1 9601 3000 psid (high collapse)
4 4704 150 psid (coreless)
TABLE 3: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
TABLE 4: PORT SIZE OPTIONS
Code Size
20 1-1/4"
24 1-1/2"
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
*4711 only. *Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model code (e.g., PH, DH, etc.).
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
B 50 psid- 4710/14 only
C 50 psid bypass with reverse flow-4710 only
W Non-bypass- 4711 only
K Non-bypass with reverse flow-4711 only
© Copyright Pall Corporation Visit us on the Web at www.pall.com
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
8340/70 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 400 gpm (1500 L/min) Pressures to 400 psi (28 bar) Port sizes: 3" and 4"
Specifications
Features
� 8310 or 8314 Assembly (Ultipor® III Element) � Commuter Valve - Built in Design Requires No External Lines. Use to Equalize Pressure During
Element Change � Duplex Check Valve at Outlet - Seals Off-Line Filter to Prevent Backflow; Simplifies Element Change � Ball Type Open Center Transfer Valve - Ensures Continuous Filtration While Changing Elements
Without Shutting Down the Machine
Maximum Acceptable Working Pressure: 400 psi (28 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 330 psi (23 bar) Typical Burst Pressure: 2100 psi (145 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights:
Filter Element Collapse Pressure: 8310–100 psid (7 bar) 8314–150 psid (10 bar) Materials of Construction: Head, cover, handle, tube, manifold and valve bodies – aluminum alloy. Center post, core, and internal valve parts – coated carbon steel. Dimensional Drawings
8340/8370: U length–165 lbs. (75 kg)X length– 260 lbs. (118 kg)
8342/8372: X length– 475 lbs. (215 kg)8343/8373: X length– 680 lbs. (310 kg)8344/8374: X length– 890 lbs. (405 kg)
Performance
Element Pressure Drop Factor* Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.
8310/14 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
16" 0.089 0.047 0.040 0.031 0.022
39" 0.034 0.018 0.015 0.012 0.008
* Based on flow through each housing/element. Divide total flow by number of housings per side to determine flow per each housing/element.
Assembly P/N: H 83 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
Element P/N: HC 83 F Table2 Table5 Table6 Table1
Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Assembly Code Element Code* Description
4 10 Conventional
7 14 Coreless
*Nominal length in inches. Use code in second column for element part no.
TABLE 3: QUANTITY OF HOUSINGS
Code Description
0 2 Housings (1/side)
2 4 Housings (2/side)
3 6 Housings (3/side)
4 8 Housings (4/side)
TABLE 4: PORT SIZE OPTIONS
Code Size
D48 3" flange SAE J518c-Code 61
D64 4" flange SAE J518c-Code 61
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code**
U 16
X 39
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
Y Non-bypass with 16 psid indicator
N Non-bypass with 35 psid indicator
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
2 'P' and 'L'
3 'P' and 'S'
Electrical indicators in base only.
© Copyright Pall Corporation Visit us on the Web at www.pall.com
8384/85 Series Service Bypass Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 200 gpm (760 L/min) Pressures to 400 psi (28 bar) Port sizes: 2" and 2-1/2" SAE split flange
Specifications
Features
� Optional Differential Pressure Device � Changeover Handle with Latching Pin Mechanism � 8310 or 8314 Series (Ultipor® III Element)
Maximum Acceptable Working Pressure: 400 psig (28 bar) Fatigue Pressure Rating: 330 psig (23 bar) (107 cycles per NFPA T2.6.1-1974) Typical Burst Pressure: 2100 psig (145 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 8314–150 psid (10 bar) 8310–100 psid (7 bar) Materials of Construction: Head, cover, handle, tube, manifold and valve bodies – aluminum alloy. Center post, core, and internal valve parts – coated carbon steel.
Performance
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
8310/14 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
16" 0.089 0.047 0.040 0.031 0.022
39" 0.034 0.018 0.015 0.012 0.008
Assembly P/N: H 838 D Table1 Table2 Table3 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 831 F Table4 Table5 Table6 Table1
Table 1: Seal Options
Code Seals
H Buna N
Z Fluorocarbon
Table 2: Housing Series Options
Code Element
4 Coreless (use Code '4' in table 4)
5 Standard (use Code '0' in table 4)
Table 3: Port Size Options
Code Size
32 2" SAE flange
40 2-1/2" SAE flange
*Caution: If non-bypass configuration is selected, do not use in systems with surge pressures over 90 psig (8385) or 120 psig (8384), in order to avoid possible filter element collapse and containment passing
downstream.
Table 4: Element Series Options
Code Options
4 8314 series coreless filter elements
0 8310 series filter elements (with core)
Table 5: Filter Element Options
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
Table 6: Length Options*
Assembly Code Element Code** Dry Weight Maximum
U 16 61 lb.
X 39 82 lb.
* Use code in second column for element part no. ** Nominal length in inches.
Table 7: Bypass Valve Options
Code Description
A 25 psid ± 3 psid bypass
B 50 ± 5 psid bypass
Y Without bypass* 16 psid P indicator
N Without bypass* 35 psid P indicator
1 Without bypass* with P device F or B
Table 8: Differential Pressure Device Options
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Code Description Location
B Plug in place of P device Both
P Visual indicator with thermal lockout Cover
D 'P' type with no thermal lockout Cover
L Electrical switch (SPDT) with 6" leads Base
S Electrical switch with MS receptacle Base
T 'L' type with DIN connector Base
M 'T' type with wiring cap Base
2 'P' and 'L' As above
3 'P' and 'S' As above
Table 9: Handle Orientation Options
Code Handle Orientation
L Handle on left side when facing inlet port
R Handle on right side when facing inlet port
8670/71/74 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 50 gpm (190 L/min) Pressures to 1200 psi (80 bar) Port sizes: 1-1/4"
Specifications
Features
� Non-Welded Construction (Gray Iron Head) � Vent Plugs � Changeover Handle with Latching Pin Mechanism � Filter Element Change Instruction Plate � Forged Steel Bowls � Commuter Valve (To Repressurize Idle Side After Element Change) � O-Ring Seals Throughout � Filter "In-Service" Pointer � Differential Pressure Device (Optional) � Ultipor® III Element � Drain Plug
Maximum Acceptable Working Pressure: 1200 psi (80 bar) Typical Burst Pressure: 5500 psi (380 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 65 lbs. (29 kg) T length– 75 lbs. (33.5 kg) U length– 85 lbs. (38 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 4704–150 psid (10 bar)
Performance
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
9600/4704 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.46 0.20 0.17 0.12 0.09
13" 0.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
9601 Series Element P factor (psid/gpm)
Length DP DT
8" 0.52 0.12
13" 0.32 0.08
16" 0.25 0.07
Assembly P/N: H 867 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Element P/N: HC F Table2 Table4 Table5 Table1
Table 1: Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 2: Element Options
Assembly Code Element Code Rating
0 9600 290 psid (standard)
1 9601 3000 psid (high collapse)
4 9604 150 psid (coreless)
Table 3: Port Options
Code Description
A20 1-1/4" SAE J514 straight thread
D20 1-1/4" Flange SAE J518c-code 61
Table 4: Filter Element Options
Code ßX 200 ßx(c) = 1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
* 8671 only.
Table 5: Length Options*
Assembly Code Element Code**
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
Table 6: Bypass Valve Options
Code Description
A* 25 psid bypass 8670/8674 only
B 50 psid bypass 8670/8674 only
W Non-bypass 8670 to 120 psi max. 8671 to 1200 psi max. Not available for 8674.
* A valve-25 gpm max flow.
Table 7: Differential Pressure Device Options
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M 'T' type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
9685 Series Service Bypass Filter Assemblies
Description
Flows to 65 gpm (250 L/min) Pressures to 6000 psi (400 bar) Port sizes: 1-1/4"
Specifications
Features
� Ductile Iron Head � Commuter Valve (To Repressurize After Element Change) � Bleed Valve � O-Ring Seals � Ultipor® III Element � Drain Port and Plug � Optional Differential Pressure Device � Stainless Steel Bypass Valve with Nylon Poppet (Not Shown) � Stainless Steel Ball Valve with PTFE Seats (Not Shown) � Change Over Handle with Latching Pin Mechanism � All Non-Stainless Steel Parts Corrosion Protected
Maximum Acceptable Working Pressure: 6000 psi (400 bar) Fatigue Pressure Rating: 4000 psi (275 bar) Typical Burst Pressure: 24,360 psi (1680 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 45 lbs. (21 kg) T length– 50 lbs. (23 kg) U length– 55 lbs. (25 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific
gravity.
9600 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.46 0.20 0.17 0.12 0.09
13" 0.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
Assembly P/N: H 9685 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Element P/N: HC 9600 F Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
D Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
TABLE 3: PORT SIZE OPTIONS
Code Size Style Availability
20 1-1/4" All
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 5: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
T 13
© Copyright Pall Corporation Visit us on the Web at www.pall.com
U 16
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
L 58 psid
TABLE 7: Differential Pressure Device Options
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Bleed plug and seal in place of indicator
All differential pressure devices for the 9685 set at 44 psid.
4740/41/44 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 90 gpm (340 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1-1/2"
Specifications
Features
� Open Center Transfer Valve 3-Way Ball Type � Low Torque Handle � O-Ring Seals � Optional Differential Pressure Devices � Bleed Valves � Commuter Valve � Ultipor® III Element
Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: 5800 psi (400 bar) with stainless steel indicator Typical Burst Pressure: 23,200 psi (1600 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 114 lbs. (52 kg) T length– 120 lbs. (55 kg) U length– 131 lbs. (60 kg) Filter Element Collapse Pressure: 9600-290 psid (20 bar) 9601-3000 psid (207 bar) 4704-150 psid (10 bar) Materials: –Ductile iron head –Forged steel bowls
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.
9600/4704 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.46 0.20 0.17 0.12 0.09
13" 0.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
9601 Series Element P factor (psid/gpm)
Length DP DT
8" 0.52 0.12
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
13" 0.32 0.08
16" 0.25 0.07
Assembly P/N: H 474 24 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Element P/N: HC F Table2 Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Assembly Code Element Code Rating
0 9600 290 psid (standard)
1 9601 3000 psid (high collapse)
4 4704 150 psid (coreless)
TABLE 3: PORT OPTIONS
Code Port Style
A SAE J514 straight thread
D* Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
*D ports rated at 3000 psi (207 bar).
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
* 4741 only.
TABLE 5: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
B 50 psid-4740/44 only
W Non-bypass-4741 only
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
Note: Above indicators fatigue rated at 3000 psi. For cyclic pressure above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model code (e.g., PH, DH, etc.).
© Copyright Pall Corporation Visit us on the Web at www.pall.com
6220 Series Filter Assembies
Description
Flows to 40 gpm (150 L/min) Pressures to 150 psi (10 bar) Port size: 1"
Specifications
Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Maximum Operating Pressure: 150 psi (10 bar) Typical Burst Pressure: 1200 psi (83 bar) Filter Element Collapse Pressure: 290 psid (20 bar) minimum Fluid Compatibility: Petroleum oils, water glycols, water-oil emulsions, and HWCF. Fluorocarbon seals required for industrial phosphate esters, diesters, and specified synthetics. 140°F (60°C) max in water containing fluids. Materials of Construction: Aluminum alloy head, cover and canister
Dimensional Drawings
Performance
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
6200 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
4" 1.1 0.56 0.30 0.19 0.14
8" 0.53 0.27 0.15 0.10 0.07
Assembly P/N: H 6220 A 16 B Table1 Table2 Table3 Table4
Element P/N: HC 6200 F Table2 Table3 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 3: LENGTH OPTIONS*
Assembly Code Element Code** Assembly Dry Wt. (lbs.)
R 4 2.2
S 8 2.4
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 4: P DEVICE OPTIONS
Code P Option H Dim.
G Pressure gauge (0-150 psi) 1.25" (32 mm)
B Plugged 1/8" NPT gauge port supplied 0.5" (12 mm)
8 Electrical absolute pressure switch. Electrical ratings suffix 24 volts DC–24 DC 220 volts AC-220 AC
2.7" (69 mm)
© Copyright Pall Corporation Visit us on the Web at www.pall.com
6300 Series Filter Assemblies
Description
Flows to 120 gpm (450 L/min) Pressures to 250 psi (17 bar) Port sizes: 1-1/4" and 1-1/2"
Specifications
Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 250 psi (17 bar) Typical Burst Pressure: 1200 psi (83 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 18.5 lbs. (8.4 kg) T length– 20.0 lbs. (9.1 kg) U length– 23.5 lbs. (10.7 kg) V length– 27.0 lbs. (12.3 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
6300 Series Element P factor (psid/gpm)
Length DP DN DS DT
8" 0.29 0.18 0.13 0.09
13" 0.19 0.10 0.08 0.07
16" 0.14 0.08 0.06 0.05
26" 0.11 0.05 0.04 0.03
Assembly P/N: H 6300 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 6300F Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT
D Flange SAE J518c-Code 61
TABLE 3: INLET PORT SIZE OPTIONS
Code Size
20 1-1/4"
24 1-1/2"
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
DP 3 5
DN 6 7
DS 12 12
DT 25 22
TABLE 5: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
T 13
U 16
V 26
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
W Non-bypass
8 25 psid with ABFV*
9 50 psid with ABFV
V Non-bypass with ABFV
* ABFV- Anti-backflow valve.
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
PM Visual indicator with thermal lockout
DM Visual indicator with no thermal lockout
© Copyright Pall Corporation Visit us on the Web at www.pall.com
LL Electrical switch (SPDT) with 6" leads
TL Electrical switch with DIN connector
ML ‘TL’ type switch with matching wiring cap
SL Electrical switch with MS receptacle
BL Plug in place of indicator
PL Same as PM but with plastic body
DL Same as DM but with plastic body
Indicator and switch pressure settings. 16 psid with "A" and "8" bypass valve. 35 psid with "W," "V," "B," and "9" option.
TABLE 8: SECONDARY PORT OPTIONS
Code Port Option Port Size
S Port machined 1"
N Non-machined -
Port opposite main inlet in style consistent with main inlet port (see Table 2) except that "A" style secondary port is used with "D" style main inlet port.
TABLE 9: AUXILIARY PORT OPTIONS
Code Port Option Port Size
R Right side* 3/4"
L Left side* 3/4"
B Both 3/4"
N Non-machined -
* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2), except that "A" style auxiliary port(s) is used with "D" style main inlet port.
6400 Series Filter Assemblies
Description
Flows to 200 gpm (755 L/min) Pressures to 250 psi (17 bar) Port sizes: 1-1/2" and 2"
Specifications
Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 250 psi (17 bar) Typical Burst Pressure: 1200 psi (83 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 22.5 lbs. (10.2 kg) T length– 23.7 lbs. (10.8 kg) U length– 25.0 lbs. (11.3 kg) V length– 31.0 lbs. (14.1 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
6400 Series Element P factor(psid/gpm)
Length DP DN DS DT
8" 0.26 0.16 0.12 0.08
13" 0.17 0.09 0.07 0.06
16" 0.13 0.07 0.05 0.04
26" 0.10 0.05 0.04 0.03
Assembly P/N: H 6400 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 6400F Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT
D Flange SAE J518c-Code 61
TABLE 3: INLET PORT SIZE OPTIONS
Code Size
20 1-1/4"
24 1-1/2"
TABLE 4: FILTER Element OPTIONS
Code ßx 200 ßx(c)=1000
DP 3 5
DN 6 7
DS 12 12
DT 25 22
TABLE 5: LENGTH OPTIONS*
Assembly Code Element Code**
S 8
T 13
U 16
V 26
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
W Non-bypass
8 25 psid with ABFV*
9 50 psid with ABFV
V Non-bypass with ABFV
* ABFV- Anti-backflow valve.
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
PM Visual indicator with thermal lockout
DM Visual indicator with no thermal lockout
LL Electrical switch (SPDT) with 6" leads
TL Electrical switch with DIN connector
© Copyright Pall Corporation Visit us on the Web at www.pall.com
ML ‘TL’ type switch with matching wiring cap
SL Electrical switch with MS receptacle
BL Plug in place of indicator
PL Same as PM but with plastic body
DL Same as DM but with plastic body
Indicator and switch pressure settings. 16 psid with "A"and "8" bypass valve. 35 psid with "W," "V," "B," and "9" option.
TABLE 8: SECONDARY PORT OPTIONS
Code Port Option Port Size
S Port machined 1-1/4"
N Non-machined -
Port opposite main inlet in style consistent with main inlet port (see Table 2).
TABLE 9: AUXILIARY PORT OPTIONS
Code Port Option Port Size
R Right side* 1"
L Left side* 1"
B Both 1"
N Non-machined -
* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2), except that "A" style auxiliary port(s) is used with "D" style main inlet port.
6500 Series Filter Assemblies
Description
Flows to 300 gpm (1135 L/min) Pressures to 250 psi (17 bar) Port sizes: 2" and 2-1/2"
Specifications
Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 250 psi (17 bar) Typical Burst Pressure: 1200 psi (83 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: T length– 26.0 lbs. (11.8 kg) U length– 30.0 lbs. (13.6 kg) V length– 35.5 lbs. (16.1 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)
Dimensional Drawings
Performance
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
6500 Series Element P factor (psid/gpm)
Length DP DN DS DT
13" 0.14 0.08 0.06 0.05
16" 0.11 0.06 0.04 0.04
26" 0.08 0.04 0.03 0.02
Assembly P/N: H 6500 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Element P/N: HC 6500F Table4 Table5 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: PORT STYLE OPTIONS
Code Port Style
A SAE J514 straight thread
B NPT
D Flange SAE J518c-Code 61
TABLE 3: INLET PORT SIZE OPTIONS
Code Size
32 2"
40 2-1/2"
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
DP 3 5
DN 6 7
DS 12 12
DT 25 22
TABLE 5: LENGTH OPTIONS*
Assembly Code Element Code**
T 13
U 16
V 26
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
A 25 psid
B 50 psid
W Non-bypass
8 25 psid with ABFV*
9 50 psid with ABFV
V Non-bypass with ABFV
* ABFV- Anti-backflow valve.
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
PM Visual indicator with thermal lockout
DM Visual indicator with no thermal lockout
LL Electrical switch (SPDT) with 6" leads
TL Electrical switch with DIN connector
ML ‘TL’ type switch with matching wiring cap
SL Electrical switch with MS receptacle
BL Plug in place of indicator
© Copyright Pall Corporation Visit us on the Web at www.pall.com
PL Same as PM but with plastic body
DL Same as DM but with plastic body
Indicator and switch pressure settings 16 psid with "A"and "8" bypass valve 35 psid with "W," "V," "B," and "9" option.
TABLE 8: SECONDARY PORT OPTIONS
Code Port Option Port Size
S Port machined 1-1/2"
N Non-machined -
Port opposite main inlet in style consistent with main inlet port (see Table 2).
TABLE 9: AUXILIARY PORT OPTIONS
Code Port Option Port Size
R Right side* 1-1/4"
L Left side* 1-1/4"
B Both 1-1/4"
N Non-machined -
* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2).
301/381 Series ASME Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 150 gpm (570 lpm), 301 Series; 300 gpm (1135 lpm), 381 Series Pressures to 675 psig (46.5 bar) Port Sizes: 2", 3", and 4" ANSI Flange Connections
Specifications
Maximum Acceptable Working Pressure: Class 150: 260 psig (18 bar); Class 300: 675 psig (46.5 bar) at 200°F (93°C) Temperature Range: -20°F to 200°F (-29°C to 93°C); 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 150 psid (10 bar) Hydrostatic Test Pressure: Class 150: 390 psig (26.9 bar) Class 300: 1013 psig (69.8 bar) Materials of Construction: Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless steel 304L valve ball and stem on “D” duplex model Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve body, valve ball, and stem on “D” duplex model Finish: Interior finish: coated with rust preventative Permanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.
Dimensional Drawings
Performance
Dimensions (301 Series)
Port Size
‘A’ Simplex Only
‘B’ Duplex Only
‘C’ Duplex Only
‘D’ ‘E’ ‘F’ Duplex Only
‘G’ ‘L’ V-Length
‘L’ X-Length
JO2 7.88 3.94 19.69 6.00 8.66 5.12 6.63 46.06 59.06
J03 7.88 5.12 20.87 6.00 11.42 6.89 6.63 46.06 59.06
Dimensions (381 Series)
Port Size
‘A’ Simplex Only
‘B’ Duplex Only
‘C’ Duplex Only
‘D’ ‘E’ ‘F’ Duplex Only
‘G’ ‘L’ V-Length
‘L’ X-Length
JO3 10.00 5.12 25.12 8.00 11.42 6.89 8.63 N/A 61.75
J04 10.00 5.90 25.90 6.00 13.78 7.28 8.63 N/A 61.75
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Maximum Clean Element Pressure Drop for Bypass Valves Calculated clean element pressure drop should not exceed the values listed in the table for the selected bypass valve option.
Housing Pressure drop is directly proportional to specific gravity. 301 Series with 8904 Elements
381 Series with 8314 Elements
8904 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
26" 0.10 0.044 0.037 0.028 0.019
39" 0.062 0.029 0.024 0.018 0.013
8314 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
39" 0.034 0.018 0.015 0.012 0.008
Bypass ‘E’ ‘F’ ‘D’ ‘A’ ‘B’ ‘W’
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
Option (5 psid) (12 psid) (18 psid) (25 psid) (50 psid) (non-bypass)
Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P
Assembly P/N: H 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Replacement Element P/N: HC 8904F
Table5 Table6 Table1 HC 8314F
Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: HOUSING OPTION*
Code Option
01 8904 element
81 8314 element
*Housings accept a single element.
TABLE 3: HOUSING STYLE OPTIONS
Code Style
S Simplex - ports on same side
D Duplex
TABLE 4: PORT OPTIONS
Code Port Availability
J02 2" ANSI B16.5 class 150 flanges 301 series
J03 3" ANSI B16.5 class 150 flanges 301 and 381 series
J04 4" ANSI B16.5 class 150 flanges 381 series
N02 2" ANSI B16.5 class 300 flanges 301 series
N03 3" ANSI B16.5 class 300 flanges 301 and 381 series
N04 4" ANSI B16.5 class 300 flanges 381 series
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code** Availability
V 26 301 series only
X 39 301 and 381 series
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Cracking Pressure
A 25 psid
B 50 psid
D 18 psid
E 5 psid
F 12 psid
W Non-bypass
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
O No indicator
B Bleed plug and seal in place of indicator
P Visual indicator with thermal lockout
S Electrical switch with MS receptacle
L Electrical switch with 6" leads
V Electrical/visual indicator
TABLE 9: HOUSING MATERIAL OPTIONS
Code Option
© Copyright Pall Corporation Visit us on the Web at www.pall.com
7 Carbon steel
9 304L stainless steel
307/387 Series ASME Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 900 gpm (3406 lpm), 307 Series; 1500 gpm (5678 lpm), 387 Series Pressures to 675 psig (46.5 bar) Port Sizes: 4" and 6" ANSI Flange Connections
Specifications
Maximum Acceptable Working Pressure: Class 150: 260 psig (18 bar); Class 300: 675 psig (46.5 bar) at 200°F (93°C) Temperature Range: -20°F to 200°F (-29°C to 93°C); 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 150 psid (10 bar) Hydrostatic Test Pressure: Class 150: 390 psig (26.9 bar) Class 300: 1013 psig (69.8 bar) Materials of Construction: Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless steel 304L valve ball and stem on “D” duplex model Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve body, valve ball, and stem on “D” duplex model Finish: Interior finish: coated with rust preventative Permanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.
Dimensional Drawings
Performance
Dimensions (307 Series)
Port Size
‘A’ Simplex Only
‘B’ Duplex Only
‘C’ Duplex Only
‘D’ ‘E’ ‘F’ Duplex Only
‘G’ ‘L’ V-Length
‘L’ X-Length
JO4 11.85 5.90 29.60 8.00 13.78 7.28 14.00 50.06 63.06
J06 11.85 11.81 35.50 6.50 23.62 8.46 14.00 59.90 72.90
Dimensions (387 Series)
Port Size
‘A’ Simplex Only
‘B’ Duplex Only
‘C’ Duplex Only
‘D’ ‘E’ ‘F’ Duplex Only
‘G’ ‘L’ V-Length
‘L’ X-Length
JO6 17.85 11.81 47.50 8.00 23.62 8.46 20.00 N/A 72.75
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
*Factors listed above have been adjusted to represent the total number of elements per housing.
Housing Pressure drop is directly proportional to specific gravity. 307 Series with 8904 Elements
387 Series with 8314 Elements
*8904 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
26" 0.014 0.006 0.005 0.004 0.003
39" 0.009 0.004 0.003 0.003 0.002
*8314 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
39" 0.0049 0.0026 0.0021 0.0017 0.0011
Maximum Clean Element Pressure Drop for Bypass Valves Calculated clean element pressure drop should not exceed the values listed in the table for the selected bypass valve option.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
Bypass Option
‘E’ (5 psid)
‘F’ (12 psid)
‘D’ (18 psid)
‘A’ (25 psid)
‘B’ (50 psid)
‘W’ (non-bypass)
Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P
Assembly P/N: H 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Replacement Element P/N: HC 8904F
Table5 Table6 Table1 HC 8314F
Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: HOUSING OPTION*
Code Option
07 8904 element
87 8314 element
*Housings accept 7 elements.
TABLE 3: HOUSING STYLE OPTIONS
Code Style
S Simplex - ports on same side
D Duplex
TABLE 4: PORT OPTIONS
Code Port Availability
J04 4" ANSI B16.5 class 150 flanges 307 series
J06 6" ANSI B16.5 class 150 flanges 307 and 387 series
N04 4" ANSI B16.5 class 300 flanges 307 series
N06 6" ANSI B16.5 class 300 flanges 307 and 387 series
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code** Availability
V 26 307 series only
X 39 307 and 387 series
* Use Code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Cracking Pressure
A 25 psid
B 50 psid
D 18 psid
E 5 psid
F 12 psid
W Non-bypass
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
O No indicator
B Bleed plug and seal in place of indicator
© Copyright Pall Corporation Visit us on the Web at www.pall.com
P Visual indicator with thermal lockout
S Electrical switch with MS receptacle
L Electrical switch with 6" leads
V Electrical/visual indicator
TABLE 9: HOUSING MATERIAL OPTIONS
Code Option
7 Carbon steel
9 304L stainless steel
303/383 Series ASME Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 400 gpm (1510 lpm), 303 Series; 700 gpm (2650 lpm), 383 Series Pressures to 675 psig (46.5 bar) Port Sizes: 2", 3", 4" and 6" ANSI Flange Connections
Specifications
Maximum Acceptable Working Pressure: Class 150: 260 psig (18 bar); Class 300: 675 psig (46.5 bar) at 200°F (93°C) Temperature Range: -20°F to 200°F (-29°C to 93°C); 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 150 psid (10 bar) Hydrostatic Test Pressure: Class 150: 390 psig (26.9 bar) Class 300: 1013 psig (69.8 bar) Materials of Construction: Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless steel 304L valve ball and stem on “D” duplex model Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve body, valve ball, and stem on “D” duplex model Finish: Interior finish: coated with rust preventative Permanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.
Dimensional Drawings
Performance
Dimensions (303 Series)
Port Size
‘A’ Simplex Only
‘B’ Duplex Only
‘C’ Duplex Only
‘D’ ‘E’ ‘F’ Duplex Only
‘G’ ‘L’ V-Length
‘L’ X-Length
JO2 10.00 3.94 23.94 8.00 8.66 5.12 10.75 50.06 63.06
J03 10.00 5.12 25.12 8.00 11.42 6.89 10.75 50.06 63.06
J04 10.00 5.90 25.90 8.00 13.78 7.28 10.75 50.06 63.06
Dimensions (383 Series)
Port Size
‘A’ Simplex Only
‘B’ Duplex Only
‘C’ Duplex Only
‘D’ ‘E’ ‘F’ Duplex Only
‘G’ ‘L’ V-Length
‘L’ X-Length
JO4 14.10 5.90 34.20 8.00 13.78 7.28 16.00 N/A 61.75
J06 14.10 11.81 40.00 8.00 23.62 8.46 16.00 N/A 61.75
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Housing Pressure drop is directly proportional to specific gravity. 303 Series with 8904 Elements
383 Series with 8314 Elements
*8904 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
26" 0.033 0.015 0.012 0.009 0.006
39" 0.021 0.010 0.008 0.006 0.004
*8314 Series Element P factor (psid/gpm)
Maximum Clean Element Pressure Drop for Bypass Valves Calculated clean element pressure drop should not exceed the values listed in the table for the selected bypass valve option.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
Length KZ KP KN KS KT
39" 0.011 0.006 0.005 0.004 0.003
*Factors listed above have been adjusted to represent the total number of elements per housing.
Bypass Option
‘E’ (5 psid)
‘F’ (12 psid)
‘D’ (18 psid)
‘A’ (25 psid)
‘B’ (50 psid)
‘W’ (non-bypass)
Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P
Assembly P/N: H 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9
Replacement Element P/N: HC 8904F
Table5 Table6 Table1 HC 8314F
Table5 Table6 Table1
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: HOUSING OPTION*
Code Option
03 8904 element
83 8314 element
*Housings accept 3 elements.
TABLE 3: HOUSING STYLE OPTIONS
Code Style
S Simplex - ports on same side
D Duplex
TABLE 4: PORT OPTIONS
Code Port Availability
J02 2" ANSI B16.5 class 150 flanges 303 series
J03 3" ANSI B16.5 class 150 flanges 303 series
J04 4" ANSI B16.5 class 150 flanges 303 and 383 series
J06 6" ANSI B16.5 class 150 flanges 383 series
N02 2" ANSI B16.5 class 300 flanges 303 series
N03 3" ANSI B16.5 class 300 flanges 303 series
N04 4" ANSI B16.5 class 300 flanges 303 and 383 series
N06 6" ANSI B16.5 class 300 flanges 383 series
TABLE 5: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 6: LENGTH OPTIONS*
Assembly Code Element Code** Availability
V 26 303 series only
X 39 303 and 383 series
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS
Code Cracking Pressure
A 25 psid
© Copyright Pall Corporation Visit us on the Web at www.pall.com
B 50 psid
D 18 psid
E 5 psid
F 12 psid
W Non-bypass
TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
O No indicator
B Bleed plug and seal in place of indicator
P Visual indicator with thermal lockout
S Electrical switch with MS receptacle
L Electrical switch with 6" leads
V Electrical/visual indicator
TABLE 9: HOUSING MATERIAL OPTIONS
Code Option
7 Carbon steel
9 304L stainless steel
2544 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 120 gpm (454 L/min) Pressures to 500 psi (34.5 bar) Port sizes: 1-1/4" and 1-1/2"
Specifications
Maximum Acceptable Working Pressure: 500 psi (34.5 bar) Bypass Valve: 25 psid (1.724 bar) Seals: Nitrile–Compatible with petroleum oils, water-oil emulsions and water-glycol Temperature Range: -45°F to 225°F (-43°C to 107°C) Filter Element Collapse Pressure: 150 psid (10 bar) Materials: – Aluminum head and nipple – Aluminum and steel bypass valve – Carbon steel canister and core assembly
Dimensional Drawings
Performance
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Housing Pressure drop is directly proportional to specific gravity.
Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Note: Choose from the options in the following tables to compile the specific Product Number.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.
2544 Series Element P factor (psid/gpm)
Length KP KN KS KT
9" 0.12 0.08 0.06 0.05
19" 0.06 0.04 0.03 0.02
Assembly P/N: HH 2544 A Table1 Table2 Table3 Table4 Table5 Table6
Element P/N: HC 2544F H Table2 Table3
TABLE 1: PORT OPTIONS
Code Port Option
A20 1-1/4" SAE straight thread O-ring boss per SAE J514H
A24 1-1/2" SAE straight thread O-ring boss per SAE J514H
B20 1-1/4" NPT
B24 1-1/2" NPT
TABLE 2: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KP 3 5
KN 6 7
KS 12 12
KT 25 22
TABLE 3: LENGTH OPTIONS*
Assembly Code Element Code**
S 9
U 19
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 4: INDICATOR OPTIONS
Code Device
G Pressure gauge (25 psi), other port plugged (1/8" NPT)
8 Pressure switch (15 psi) N.O. S.P.S.T. screw terminals, other port plugged (1/8" NPT)
2 Pressure gauge (25 psi) and pressure switch (15 psi) N.O. S.P.S.T. screw terminals
B Port plugs (1/8" NPT)
TABLE 5: SECONDARY PORT OPTIONS
Code Description
OMIT No secondary port
20* 1-1/4" port (same port style as primary port)
* Available only with A24 and B24 primary ports.
© Copyright Pall Corporation Visit us on the Web at www.pall.com
TABLE 6: OUTLET OPTIONS
Code Description
OMIT 1-5/8" discharge
D Diffuser with adapter
4750/51/54 Series Filter Assemblies
Description
Featuring Coreless Element Technology Flows to 90 gpm (340 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1-1/2"
Specifications
Features
� Low Torque Handle � Commuter Valve � Optional Differential Pressure Devices � Bleed Valves � O-Ring Seals � Ultipor® III Element � Open Center Transfer Valve 3-Way Ball Type
Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: 5800 psi (400 bar) with stainless steel indicator Typical Burst Pressure: 23,200 psi (1600 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 4704– 150 psid (10 bar) Materials: –Ductile iron head –Forged steel bowls
Dimensional Drawings
Performance
Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
Ordering Information
Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.
9600/4704 Series Element P factor (psid/gpm)
Length KZ KP KN KS KT
8" 0.46 0.20 0.17 0.12 0.09
13" 0.27 0.12 0.10 0.07 0.05
16" 0.20 0.09 0.07 0.05 0.04
9601 Series Element P factor (psid/gpm)
Length DP DT
8" 0.52 0.12
13" 0.32 0.08
16" 0.25 0.07
Assembly P/N: H 475 24 Table1 Table2 Table3 Table4 Table5 Table6 Table7
Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS
Code Seals
H Nitrile
Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS
Assembly Code Element Code Rating
0 9600 290 psid (standard)
1 9601 3000 psid (high collapse)
4 4704 150 psid (coreless)
TABLE 3: PORT OPTIONS
Code Port Style
A SAE J514 straight thread
D* Flange SAE J518c-Code 61
E Flange SAE J518c-Code 62
*D ports rated at 3000 psi (207 bar).
TABLE 4: FILTER ELEMENT OPTIONS
Code ßx 200 ßx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
DP* 3 5
DT* 17 15
* 4751 only.
TABLE 5: LENGTH OPTIONS*
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Assembly Code Element Code**
S 8
T 13
U 16
* Use code in second column for element part no. ** Nominal length in inches.
TABLE 6: BYPASS VALVE OPTIONS
Code Description
B 50 psid-4750/54 only
W Non-bypass-4751 only
TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
Code Description
P Visual indicator with thermal lockout
D Visual indicator with no thermal lockout
L Electrical switch (SPDT) with 6" leads
T Electrical switch with DIN connector
M ‘T’ type switch with matching wiring cap
S Electrical switch with MS receptacle
V Combined visual/electrical with DIN connector
B Plug in place of indicator
2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
Note: Above indicators fatigue rated at 3000 psi. For cyclic pressure above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model code (e.g., PH, DH, etc.).
Ultipleat SRT Filter Assemblies
Description
Ordering Information
© Copyright Pall Corporation Visit us on the Web at www.pall.com
Data Sheet IM2035EN
2035 Series High Pressure Filter Assemblies
Features• High collapse 4500 psid (310 bard) filter element using
Rigimesh® stainless steel medium
• Flows to 38 lpm (10 gpm)
• Port sizes: 3⁄8" NPT, 1⁄2" NPT
Notes and Specifications
Maximum working pressure:6,000 psi (413 bar)
Typical burst pressure: min. 24,000 psi (1655 bar)
Temperature rating:-10°F (-23°C) to 225°F (107°C)
Materials of Construction:Head and Body: Stainless SteelSeal material: PTFE encapsulated fluorocarbon
(Nitrile and Chloroprene alsoavailable)
Filter elementcollapse pressure: 4500 psid (310 bard)Elementconstruction: Rigimesh all stainless steel (no resin
binders) medium, stainless steel end caps
Seal Material: Chloroprene, Nitrile, PTFE encapsulated fluorocarbon
Flow (gpm)
Flow (lpm)
0 4 8 12 16
∆P(p
sid)
50
40
30
20
10
0
0 15 30 45 60
2.8
1.4
0 ∆P(b
ar)
3/8˝ port
1/2˝ port
Flow (gpm)
Flow (lpm)
0 2.5 5 7.5 10
∆P(p
sid)
10
8
6
4
2
0
0 10 20 30
0.6
0.5
0.4
0.3
0.2
0.1
0 ∆P(b
ar)
NK
NJ
Pressure Drop Information
Housing Pressure DropFluid at 14.3 cSt (75 SUS), 0.88 S.G.
Housing pressure drop is directly proportional to specificgravity.
Element Pressure DropFluid at 14.3 cSt (75 SUS), 0.88 S.G.
Correct for other fluids by multiplying new viscosity incSt/14.3 (SUS/75) x new S.G./0.88.
USA25 Harbor Park DrivePort Washington, NY 11050+1 888 333 7255 (toll free in U.S. only)+1 516 484 3600 phone+1 516 484 6247 fax
United KingdomEuropa House, Havant StreetPortsmouth PO1 3PDHampshire, England+44 (0) 23 9230 3303 phone+44 (0) 23 9230 2507 faxm&[email protected] email
Visit us on the Web at www.pall.com
Pall Corporation has offices and plants throughout the world in locations including:Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India,Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand,Norway, Poland, Puerto Rico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland,Taiwan, Thailand, United Kingdom, United States, and Venezuela. Distributors are located in allmajor industrial areas of the world.
Code Bypass Valve ✖ Type
W Non-bypass,(100 psid indicator settingwhere equipped)
Code Seal◆ Material
H NitrileP ChloropreneZ PTFE
encapsulatedfluorocarbon
Part Numbers/Ordering InformationH ◆ 2035 ▼ ■ ● ✖ v ❚ (e.g., HZ2035B06NKRWE1)
Bulletin #IM2035EN 2/07
© Copyright 2007, Pall Corporation. Pall, , and Rigimesh are trademarks of Pall Corporation. ® Indicates a Palltrademark registered in the USA. is a service mark of Pall Corporation.
Code Type of▼ Port
B06 3⁄8" NPTB08 1⁄2" NPT
Code Filter Media■ Grade Options
NK 5 µmNJ 10 µm++ Housing only
Dimensional Drawings
Rigimesh Element Part NumberHC2035E ■ 4 ◆ Y923 (e.g., HC2035ENK4ZY923)
Code Filter Media■ Grade Options
NK 5 µm(3)
NJ 10 µm(3)
Code Seal◆ MaterialH NitrileP Chloroprene
Z PTFE encapsulatedfluorocarbon
Code Additional❚ Options
Omit None
1 Mountingbracketassembly
.17
∅ 3.97
∅2 .97
1.05 (0.28 with BH plug)
3.85
6.67
.33
1” HEX
2.75
1.102
.984
.984
3.00
1.102
.75
1.735 1.735
4X .375-16 LNC-2BTHREAD .70 DEEP
INLETOUTLET
OUTLET INTL
ET
FRONT VIEW (1)(2)
TOP VIEW (1)(2)
1 Dimensions are in inches.2 3.0" required for element removal.3 98% efficiency.
Code Length● (nominal)
R 4"
Code ∆P Devicev Options
E visual, 6,000 psirated
0 No port
BH Plug
Features• Ultipor® III or Rigimesh® stainless steel media• Flows to 75 lpm (20 gpm) • Pressures:
2050 Series: 690 bar (10,000 psi) 2060 Series: 1034 bar (15,000 psi)2070 Series: 1379 bar (20,000 psi)
• Port sizes: 3/8″, to 3/4″
Notes and SpecificationsMaximum Working Pressure:
2050 series: 690 bar (10,000 psi)2060 series: 1000 bar (14,500 psi)2070 series: 1379 bar (20,000 psi)
Proof Pressure:2050 series: 1034 bar (15,000 psi)2060 series: 1500 bar (21,750 psi)2070 series: 2068 bar (30,000 psi)
Typical Burst Pressure:2050 series: 2758 bar (40,000 psi)2060 series: 3490 bar (50,750 psi)2070 series: 5516 bar (80,000 psi)
Temperature Range: Nitrile seals: -43˚C to 107˚C (-45˚F to 225˚F)Fluorocarbon Seals: -29˚C to 120˚C (–20˚F to 250˚F)60˚C (140˚F) maximum in HWCFor water glycol fluids with Ultipor III media
Filter Element Collapse Pressure: 9020 series: 20 bar (290 psid);
9021 series: 207 bar (3000 psid);310 bar (4500 psid) with Rigimesh all stainless steel media (NK or NJ options)
Materials of Construction: Stainless steel; titanium bowl(2070/71)
Element Construction: Ultipor III: Inorganic fibers impreg-nated and bonded with epoxyresins; stainless steel hardware.Rigimesh: All stainless steel (noresin binders)
Pressure Drop InformationFigure 1. Housing pressure drop using fluid with 0.9 S.G. Housing pressure drop is directly proportional to specific gravity.2050/2060 Series
2070 Series
Element Pressure Drop Multiply actual flow rate times factor to determine pressure dropwith fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids bymultiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9.Note: factors are per 1000 lpm and per 1 gpm.
9020 Series Filter Elements — bar/1000 lpm (psid/gpm)
Length Code KZ KP KN KS KT
4 34.61 (1.90) 14.94 (0.82) 9.84 (0.54) 6.38 (0.35) 3.83 (0.21)8 17.49 (0.96) 7.47 (0.41) 4.92 (0.27) 3.28 (0.18) 2.00 (0.11)
9021 Series Filter Elements — bar/1000 lpm (psid/gpm)
Length Code DP DS/NK DT/NJ
4 49.37 (2.71) 36.54 (0.53) 12.39 (0.68)8 24.59 (1.35) 17.24 (0.25) 6.19 (0.34)
2050/2060/2070 SeriesHigh Pressure Filter Assemblies
2050, 2060, and 2070 series filter housings
Data Sheet PM&E 2050/2060/2070-A
0
10
20
30
40
50
0 2 4 6 8 10 12 14 20
0 10
Flow (gpm)
Δ P
(bar
)
Δ P
(psi
d)
Flow (lpm)
16 18
V06 B06V09V09
, C, W, C, WA, BA, BBB08/121
20 30 40 50 60
0
1.0
2.0
3.0
70
0
10
20
30
40
50
0 2 4 6 8 10 12 14 16
0 10
Flow (gpm)
P (b
ar)
P (p
sid)
Flow (lpm)
V06V09W12V12
20 30 40 50 60
0
1.0
2.0
3.0
2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 1
Dimensional Drawings
Ordering Information
Assembly P/N: H 20 T
Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8
Ultipor Element P/N: HC F Y923
Table 2 Table 4 Table 5 Table 1
Rigimesh Element P/N: HC 9021 E
Table 4 Table 5 Table 1
Table 3: Port Options
Code Port SeriesA08 1/2″ SAE J514 straight thread 2050/51, 2060/61
A12 3/4″ SAE J514 straight thread 2050/51
B06 3/8″ NPT 2050/51, 2060/61
B08 1/2″ NPT 2050/51, 2060/61
B12 3/4″ NPT 2050/51
C08 1/2″ BSP ISO 228 threads 2050/51, 2060/61
C12 3/4″ BSP ISO 228 threads 2050/51
V06 3/8″ medium pressure threaded 2050/51, 2060/61, 2070
V09 9/16″ medium pressure threaded 2050/51, 2060/61, 2070
V12 3/4″ medium pressure threaded 2050/51, 2060/61, 2070
W12 3/4″ weld sockets 2050/51
Table 6: Bypass Valve Options
Code Valve Housing SeriesB 3.4 bar (50 psid ) 2050, 2060, 2070
J 10 bar (150 psid ) 2051, 2061, 2071
S 13.8 bar (200 psid ) 2051, 2061, 2071
W Non-bypass, 100 psid indicator 2051, 2061, 2071*
N Non-bypass, 35 psid indicator 2051, 2061, 2071*
Table 7: Differential Pressure Indicator Options*
Code Indicator ‘H’ Dim.W Explosion proof 79 mm (3.1 in)
E SST visual 28 mm (1.1 in)
0 No indicator port N/A
B SST port plug 3 mm (0.12 in)
Table 8: Mounting Bracket Options
Code Option0 None
1 Mounting bracket kit
*Notes: 1. Select 2 indicator option codes per housing2. Enter indicator codes alphabetically; put “0” code after alpha code if applicable3. 2070/71 series does not have indicator ports; enter “00” in part number
* Note: 2071 series does not have indicator ports
New York – USA+1 516 484 3600 telephone +1 888 333 7255 toll free+1 516 625 3825 fax
Portsmouth – UK+44 (0)23 9230 3303 telephone+44 (0)23 9230 2507 faxm&[email protected]
Visit us on the Web at www.pall.com/m&e
Table 2: Series Options
Housing Code Description Element Code50 690 bar (10,000 psi) housing with 50 psi
bypass valve 9020
60 1000 bar (14,500 psi) housing with 50 psi bypass valve 9020
70 1379 bar (20,000 psi) housing with 50 psibypass valve 9020
51 690 bar (10,000 psi) 9021
61 1034 bar (15,000 psi) 9021
71 1379 bar (20,000 psi) 9021
© Copyright 2005, Pall Corporation. Pall, , Ultipor and Rigimesh are trademarks of Pall Corporation. ® Indicates a Pall trademark registered in the USA. is a service mark of Pall Corporation.
Table 1: Seal Options
Code SealsH Nitrile
Z Fluorocarbon
Table 5: Length Options
Housing Element Length (in)Code CodeR 4 4
S 8 8
Table 4: Filter Element Options
Code Bx(c)≥ Element 1000 Series
KZ 3 9020 (Ultipor III)
KP 5 9020 (Ultipor III)
KN 7 9020 (Ultipor III)
KS 12 9020 (Ultipor III)
KT 22 9020 (Ultipor III)
DP 5 9021 (Ultipor III)
DS 12 9021 (Ultipor III)
DT 15 9021 (Ultipor III)
NK 5 µm* 9021 (Rigimesh)
NJ 10 µm* 9021 (Rigimesh)
* Nominal length
*
2X10.31 mmØ.406 in
57.15 mm2.25 in
22.10 mm.87 in
INLET OUTLET
25.4 mm1.00 in
101 mm4 in
95 mm3.75 in
Element change
1.19 Hex.
249.94 mm/9.84 in (R-length)345.44 mm/13.60 in (S-length)
150 Ref. mm 5.9 Ref. in
‘H’ Dim.Ref.
‘H’ Dim. Ref.
Visualindicator
Explosionproof indicator
69.85 mm2.75 in
30.23 mm1.19 in
OUTLET
92.20 mm3.63 in
24.99 mm.984 inINLET
OUTL
ET
24.99 mm.984 in
27.99 mm1.102 in
4 X 3/8-16 UNC 2B .70 deep
Secondary portlocation (2050/51and 2060/61 only)
Primary portlocation (2050/51and 2060/61 only)
104.8 mm4.125 in
111.4 mmØ4.385 in
Mounting dimensions same as other options.INLET
OUTL
ET
V12 portoption only
* 98% efficiency
2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 2