Transcript
Page 1: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

NEW: 2022 SeriesFilter Assembly

Data Sheet PIM 2022

Features

• 316 Stainless Steel construction

• Accepts Pall 21⁄2 ˝ diameter elements with M3 seals

• Optional bypass valve

• Flows to 110 Lpm (30 gpm)

• Pressures to: 17.9 bar (260 psi)

• Port size: 3⁄4 ˝ and 1˝

Notes and SpecificationsMaximum Working Pressure: 17.9 bar (260 psi)

40° C (104° F)Design Pressure: 13.8 bar (200 psi)

150° C (302° F)Materials of Construction: 316 stainless steel Element Construction:Poly-Fine® XLD cartridges All polypropylene constructionDynalloy® cartridges Sintered 316 stainless steel

fibersDynamesh™ cartridges Woven 316 stainless steel

wire cloth

Pressure Drop InformationFigure 1. Housing pressure drop.Housing pressure drop is directly proportional to specificgravity.

Element Pressure Drop. For liquids other than water, multiply pressure drop x newviscosity in cSt x new S.G.

1

Flow Rate (gpm)

Diff

eren

tialP

ress

ure

(psi

d)

03

0405

MEDIA

GRADE 06

09

12

40

.1

.07

.05

.04

.03

.02

.01

1

.7

.5

.4

.3

.2

2 3 4 7 10 20 30 4050 70 100

0.5

0.4

0.3

0.2

0.1

0

8

6

4

2

00

0 25 50 75 100

10 20 30Flow Rate (gpm)

Flow Rate (Lpm)

Diff

eren

tialP

ress

ure

(bar

)

Diff

eren

tialP

ress

ure

(psi

d)

Note: For liquid other than water, multiply the pressure dropby the specific gravity of the fluid.

2022 series filter housing

0.3

0.25

0.3

0.15

0.1

0.05

01 2 4 5

Flow Rate (gpm)

Diff

eren

tialP

ress

ure

(psi

d)

3 6

3.0 µm

4.5 µm

10 µm

20 µm

Dynalloy/Dynamesh Series Filter Cartridges

Poly-Fine® XLD Series Filter Cartridges

Page 2: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright 2006, Pall Corporation. Pall, , are trademarks of Pall Corporation. ® Indicates a Pall trademark registered in the USA. is a service mark of Pall Corporation.

Ordering Information

Assembly P/N: H 2022 ++ T

Table 1 Table 2 Table 4 Table 5 Table 6 Table 7

Poly-Fine XLD Cartridge P/N:XLD - U M3

Table 3 Table 4 Table 1

Dynalloy Cartridge P/N:PSP - S M3*

Table 3 Table 4

*Note: O-ring seals must be ordered separately. Order 2 pieces p/n D10540-456 for nitrile, 2 pieces p/n D10540-457 for fluorocarbon

Dynamesh Cartridge P/N:PWC - S M3*

Table 3 Table 4

*Note: O-ring seals must be ordered separately. Order 2 pieces p/n D10540-456 for nitrile, 2 pieces p/n D10540-457 for fluorocarbon

Dimensional Drawings Table 1: Seal Options

Housing Cartridge SealsCode Code*

H N Nitrile

Z V Fluoro-carbon

* Poly-Fine XLD cartridges only

Table 3: Filter Cartridge Options

Cartridge Series Code Rating Rating Method

3 3 µm

4.5 4.5 µm

10 10 µm

20 20 µm

03 3 µm

04 4 µm

05 5 µm

06 6 µm

09 9 µm

10 12 µm

40 40 µm

70 70 µm

100 100 µm

Table 6: Differential Pressure Indicator Options*

Code Indicator

E SST visual with glasscover

B SST port plug

* Note: Other indicator options available — contact factory

Table 2: Port Options

Code Port

A12 3/4 ˝ SAE J514 straight thread

B12 3/4 ˝ NPT

A16 1˝ SAE J514 straight thread

B16 NPT

Table 4: Length Options

Housing Element LengthCode Code (in)*

K 10 10

L 20 20

* Nominal length in inches

Table 5: Bypass Valve Options

Code Valve

A 1.7 bar (25 psid)

B 3.4 bar (50 psid)

N Non- bypass

Table 7: Mounting BracketOptions

Code Option

0 none

1 Mounting bracket kit

Industrial Manufacturing25 Harbor Park DrivePort Washington, NY 11050

888.333.7255 toll free516.484.3600 phone 516.484.6247 fax

Pall Corporation has offices and plants throughout the world in locations including: Argentina,Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India, Indonesia, Ireland,Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand, Norway, Poland, PuertoRico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, UnitedKingdom, United States, and Venezuela. Distributors are located in all major industrial areasof the world.

Visit us on the Web at www.pall.com/m&e

Poly-Fine XLD 99.9% efficiency

Absolute

NominalDynamesh

Dynalloy

PALL

INLET

OU

TLET

B B

4 3/16 ˝

1 1/2 ˝

1 3/16 ˝TYP

(4) 1/4-20x1/2 ˝

2 5/8 ˝

1 5/16 ˝TYP

K=13 3/4 ˝ LG Ø3 9/16 ˝

REQUIRED SPACENEEDED FOR SHELLREMOVAL

K=12-5/8 ˝L=22-1/2 ˝

L=23 3/4 ˝ LG

Page 3: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

7500/02 Series Spin-On Filter Assemblies

Description

Flows to 90 gpm (325 L/min) (7500); 150gpm (565 L/min) (7502) Pressures to 200 psi (14 bar) Port sizes: 1", 1-1/4" and 1-1/2" (7500) 1-1/2" and 2" (7502)

Specifications

Features

� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Gasket Seal � Spin-On Canister � Mounting Surface � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element � Optional Anti-Back Flow Valve (not shown). Prevents drainage of reservoir or lines where filter is

mounted below fluid level

Maximum Acceptable Working Pressure: 200 psi (14 bar) Fatigue Pressure Rating: 200 psi (14 bar) (100,000 cycles 0-200 psi) Typical Burst Pressure: 290 psi (20 bar) (Gasket extrusion) Temperature Range: Nitrile seals -20°F to 225°F (-29°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: 7500: R length–8 lbs. (3.6 kg) S length–9 lbs. (4.1 kg) 7502: R length–20 lbs. (9.1 kg) S length–22 lbs. (10 kg) Filter Element Collapse Pressure: 7500–100 psid (7 bar) 7502–100 psid (7 bar) Caution: 100 psi (7 bar) maximum for 7500/7502 Series non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings

Page 4: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Page 5: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

7502 series uses two 7500 series elements. Factors above are for flow through both elements in a 7502.

Ordering Information

7500 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" N/A 0.21 0.18 0.14 0.10

8" 0.23 0.11 0.10 0.07 0.05

7502 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" N/A 0.10 0.09 0.07 0.05

8" 0.12 0.05 0.05 0.04 0.03

Assembly P/N: H 750 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 7500 S

Page 6: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z* Fluorocarbon

*Non-standard: available for KP media only.

TABLE 2: HOUSING OPTIONS

Code Description

0 Single element

2 Double element

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D* Flange SAE J518c-Code 61

*7502 series only.

TABLE 4: PORT SIZE OPTIONS

Code Size Availability

16 1" 7500

20 1-1/4" 7500

24 1-1/2" 7500/7502

32 2" 7502*

*A & B port styles only.

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ* <1 2.5

Page 7: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

KP 3 5

KN 6 7

KS 12 12

KT 25 22

*8" length only

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R 4

S 8

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV - Anti-backflow valve.

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Page 8: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 9: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

7400 Series Spin-On Filter Assemblies

Description

Flows to 35 gpm (125 L/min) Pressures to 250 psi (17 bar) Port sizes: 3/4" and 1"

Specifications

Features

� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Gasket Seal � Spin-On Canister � Optional Anti-Back Flow Valve (not shown). Prevents drainage of reservoir or lines where filter is

mounted below fluid level � Mounting Surface � Gray Cast Iron Head � O-Ring Seal � Ultipor® III Element

Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: 250 psi (17 bar) (60,000 cycles 0-250 psi) Typical Burst Pressure: 400 psi (28 bar) Temperature Range: Nitrile seals -20°F to 225°F (-29°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 4 lbs. (1.8 kg) S length– 4.6 lbs. (2.1 kg) Filter Element Collapse Pressure: 7400 series–100 psid (7 bar) Caution: 100 psi (7 bar) maximum for 7400 Series non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings

Page 10: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

7400 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 0.82 0.36 0.30 0.22 0.15

Page 11: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

8" 0.43 0.19 0.15 0.12

Assembly P/N: H 7400 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 7400 S Table4 Table5 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z* Fluorocarbon

*Non-standard: available for KP media grade in 4" length only.

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

TABLE 3: PORT SIZE OPTIONS

Code Size

12 3/4"

16 1"

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

Page 12: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

KT* 25 22

* 4" length only.

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

R 4

S 8

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Page 13: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 14: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8924 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 75 gpm (284 L/min) Pressures to 400 psi (27.5 bar) Port sizes: 1" and 1¼"

Specifications

Maximum Acceptable Working Pressure: 400 psi (27.5 bar)

Fatigue Pressure Rating: 400 psi (27.5 bar) 0-2,000,000 cycles

Typical Burst Pressure: 1500 psi (103.4 bar)

Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure: 150 psid (10 bar)

Materials of Construction: Ductile iron head/cover Steel tube Powder coat finish

Dimensional Drawings

Page 15: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Pressure Drop Information

Page 16: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9404 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.29 0.15 0.11 0.08 0.06

13" 0.19 0.09 0.07 0.05 0.04

16" 0.09 0.05 0.04 0.03 0.02

Assembly P/N: H 8924 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 9404 F Table4 Table5 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Port Style Options

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

Page 17: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Table 3: Port Size Options

Code Size

16 1"

20 1 1/4"

Table 4: Filter Element Options

Code �x 200 �x(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 5: Length Options*

Assembly Code Element Code**

S 8

T 13

U 16

*Use code in second column for element part no. **Nominal length in inches

Table 6: Bypass Valve Options

Code Description

A 25 psid

B 50 psid

W Non bypass

Page 18: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Contact Information

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Table 7: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

S Electrical switch with MS receptacle

B Bleed plug and seal in place of indicator

3 "P" in cover, "S" in head

2 "P" in cover, "L" in head

1 Plastic plug

Page 19: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8300/04/10/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 300 gpm (1135 L/min) Pressures to 400 psi (28 bar) Port sizes: 1-1/2", 2 and 2-1/2" With Dual Manifold: Flows to 600 gpm (2270 L/min) Port Size: 3"

Specifications

Features

� T-Handle Easy Service Cover � Bleed Port Plug � O-Ring Seals � Optional Differential Pressure Devices � Anodized Aluminum Alloy-Head, Tube and Cover � Fill Port � Full Flow Fast Response Bypass Valves � Ultipor® III Element � Drain Port and Plug

Maximum Acceptable Working Pressure: 400 psi (28 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 330 psi (23 bar) Typical Burst Pressure: 2100 psi (145 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: U length– 45 lbs. (20.5 kg) X length– 92 lbs. (42 kg) Filter Element Collapse Pressure: 8300/04/14–150 psid (10 bar) 8310–100 psid (7 bar) Caution: 120 psi (8 bar) maximum for 8300/04/14 Series 80 psi (5.5 bar) maximum for 8310 Series non-bypass valve options (prevents possible filter element collapse).

Dimensional Drawings

Page 20: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Page 21: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.

Bypass valve pressure drops are directly proportional to specific gravity.

8300 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.078 0.034 0.028 0.021 0.014

39" 0.039 0.015 0.012 0.009 0.006

8304 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.101 0.049 0.041 0.031 0.022

39" 0.038 0.018 0.015 0.012 0.008

8310/14 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

Page 22: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

16" 0.089 0.047 0.040 0.031 0.022

39" 0.034 0.018 0.015 0.012 0.008

Assembly P/N: H 83 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 83 F Table2 Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Option

00 Standard capacity

04 Coreless, standard capacity

10 High capacity

14 Coreless, high capacity

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

TABLE 4: PORT SIZE OPTIONS

Code Size Style Availability

24 1-1/2" A, D

32 2" A, D

Page 23: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

40 2-1/2" D

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

U 16

X 39

* Use Code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

Y Non-bypass with 16 psid indicator

N Non-bypass with 35 psid indicator

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

Page 24: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Dual Manifold P/N: H 8300-SP2A3 Table1 Mounting Bracket P/N: 1129210

© Copyright Pall Corporation Visit us on the Web at www.pall.com

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Electrical indicators in base only.

Page 25: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8110 Series Filter Assemblies

Description

Flows to 40 gpm (145 L/min) Pressures to 600 psi (41 bar) Port sizes: 3/4" and 1"

Specifications

Features

� Optional Differential Pressure Devices � Gray Cast Iron Head � Painted External Finish � Drawn Steel Bowl � High Strength Fatigue Rated Housing � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element � Optional Drain Port (Not Shown)

Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: 600 psi (41 bar) (2,000,000 cycles to 600 psi) Typical Burst Pressure: 2400 psi (165 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 9 lbs. (4.1 kg) S length– 10 lbs. (4.6 kg) T length– 11 lbs. (5 kg) Filter Element Collapse Pressure: 9100–290 psid (20 bar)

Dimensional Drawings

Page 26: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9100 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 1.01 0.44 0.36 0.27 0.19

8" 0.53 0.25 0.21 0.16 0.11

13" 0.32 0.14 0.11 0.09 0.06

Page 27: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

Assembly P/N: H 8110 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 9100 F Table4 Table5 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

TABLE 3: PORT SIZE OPTIONS

Code Size

12 3/4"

16 1"

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 5: LENGTH OPTIONS*

Page 28: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Assembly Code Element Code**

R 4

S 8

T 13

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid ± 5

B 50 psid ± 5

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

TABLE 8: OPTIONAL DRAIN PORTS

Code Description

Omit No drain

6 1/4" SAE drain port and plug

Page 29: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8600/04/06 Series Rotolok Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 40 gpm (145 L/min) Pressures to 600 psi (41 bar) Port sizes: 3/4" and 1"

Specifications

Features

� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is

mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: 600 psi (41 bar) (2,000,000 cycles to 600 psi) Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 8 lbs. (3.6 kg) S length– 9 lbs. (4.1 kg) T length- 11 lbs. (5 kg) Filter Element Collapse Pressure: 9600–290 psid (20 bar) 9604–150 psid (10 bar) 9606–600 psid (207 bar) Caution: 120 psi (8 bar) maximum for 8600 Series non-bypass valve options (prevents possible filter element collapse).

Dimensional Drawings

Page 30: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Page 31: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9600/9604* Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 0.81 0.36 0.29 0.22 0.15

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.07 0.07 0.05

*9604 not available in 4" length.

9606 Series Element P factor (psid/gpm)

Length DS

4" 0.17

8" 0.09

13" 0.05

Assembly P/N: H 860 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 960 F Table2 Table5 Table6 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Page 32: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

CODE OPTION

0 Standard

4 Coreless

6* High collapse

* 8606 is available with non-bypass valve options and ‘DS’ filter media only.

TABLE 3: PORT STYLE OPTIONS

CODE PORT STYLE

A SAE J514 straight thread

B NPT tapered pipe thread

TABLE 4: PORT SIZE OPTIONS

CODE SIZE

12 3/4"

16 1"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßX 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DS* 12 10

* 8606 only.

Page 33: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R*** 4

S 8

T 13

* Use code in second column for element part no. ** Nominal length in inches. ***Not available for 8604 series/9604 element.

TABLE 7: BYPASS VALVE OPTIONS

CODE DESCRIPTION

A 25 psid

B 50 psid

W* Non-bypass

8 25 psid with ABFV**

9 50 psid with ABFV**

V* Non-bypass with ABFV**

* Not available for 8604. ** ABFV– Anti-backflow valve.

TABLE 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual /electrical with DIN connector

B Plug in place of indicator

Page 34: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

2804 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 45 gpm (170 L/min) Pressures to 600 psi (41.4 bar) Port size 1"

Specifications

Maximum Acceptable Working Pressure: 600 psi (41.4 bar) Fatigue Pressure Rating: 400 psi (27.5 bar) (106 cycles per NFPA T2.6.1-1991) Typical Burst Pressure: 2000 psi (140 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) Filter Element Collapse Pressure: 150 psid (10 bar) Materials of Construction: Cast Aluminum Head/Bowl Fluid Compatibility: Compatible with petroleum oils. Not recommended for use with water based fluids. Fluorocarbon seals are required for industrial phosphate esters, diesters and specified synthetics.

Dimensional Drawings

Page 35: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Pressure Drop Information

Page 36: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cST), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9104 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.53 0.25 0.21 0.16 0.11

Assembly P/N: H 2804 A 16 S Table1 Table2 Table3 Table4

Element P/N: HC 9104 F 8 Table2

Table1

Page 37: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Contact Information

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: FILTER ELEMENT OPTIONS

Code �x 200 �x(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 3: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non bypass

TABLE 4: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

Page 38: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 39: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8200/04/10/14 Series Rotolok Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 110 gpm (400 L/min) Pressures to 600 psi (41 bar) Port sizes: 1", 1-1/4" and 1-1/2"

Specifications

Features

� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is

mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: 600 psi (41 bar) 2,000,000 cycles Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 17 lbs. (7.75 kg) T length– 20 lbs. (9.1 kg) U length– 23 lbs. (10.5 kg) Filter Element Collapse Pressure: 8200–150 psid (10 bar) 9604–150 psid (10 bar)

Dimensional Drawings

Page 40: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 41: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 42: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 43: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 44: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

8200/9604 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" O.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

Assembly P/N: H 82 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 8200 (8200/10 Housing) F Table5 Table6 Table1

HC 9604 (8204/14 Housing) F Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

Page 45: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

* 'L' = L head 'T' = T head

TABLE 2: ELEMENT OPTIONS

Code Option*

00 ‘L’ (standard element)

04 ‘L’ (coreless element)

10 ‘T’ (standard element)

14 ‘T’ (coreless element)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c–Code 61

TABLE 4: PORT SIZE OPTIONS

Code Size Style Availability

16 1" A, B

20 1-1/4" A,B,D

24 1-1/2" A,B,D

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Page 46: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

8 25 psid with ABFV*

9 50 psid with ABFV*

* ABVF-anti-backflow valve available with 8214 model only.

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

1 Machined part with plastic shipping plug

TABLE 9: EJECTOR SPRING OPTIONS

Code Description

N No ejector spring

S Ejector spring

Page 47: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 48: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8800/10 Series Rotolok Filter Assemblies

Description

Flows to 120 gpm, 454 L/min Pressures to 600 psi (41 bar) Port sizes: 1-1/2" and 2"

Specifications

Features

� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is

mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 600 psi (41 bar) Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 23 lbs. (10.5 kg) T length– 25 lbs. (11.4 kg) U length– 27 lbs. (12.3 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psid (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse).

Dimensional Drawings

Page 49: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Page 50: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

8800 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.37 0.17 0.14 0.10 0.07

13" 0.23 0.10 0.08 0.06 0.04

16" 0.17 0.08 0.06 0.05 0.03

Assembly P/N: H 88 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 8800 F Table5 Table6 Table1

Table 1: Seal Options

Code Seals

Page 51: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

H Nitrile

Z Fluorocarbon

Table 2: Head Options

Code Head Option

00 'L' Head

10 'T' Head

Table 3: Port Style Options

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c-code 61

Table 4: Port Size Options

Code Size

24 1-1/2"

32 2"

Table 5: Filter Element Options

Code ßx 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 6: Length Options*

Assembly Code Element Code**

S 8

T 13

Page 52: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

U 16

* Use code in second column for element part no. ** Nominal length in inches.

Table 7: Bypass Valve Options

Code Description

A 25 psid

B 50 psid

W* Non-bypass

8* 25 psid with ABFV

9* 50 psid with ABFV

V* Non-bypass with ABFV

* ABFV- Anti-backflow valve, available for 'T' head units only: 8810.

Table 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Table 9: Auxiliary Ports

Code Auxiliary Port

N Unmachined

B Both† sides

R* Right only†

L* Left only†

Page 53: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

* Special order-contact factory. † Shipping plugs provided only.

Table 10: Ejector Spring Options

Code Description

N No ejector spring

S Ejector spring

Page 54: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8900/04/10/14 Series Rotolok Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 200 gpm (755 L/min) Pressures to 600 psi (41 bar) Port sizes: 2" and 2-1/2"

Specifications

Features

� Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � Easy Service Rotolok Ring � Drawn Steel Bowl � Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is

mounted below fluid level � High Strength Fatigue Rated Housing � Gray Cast Iron Head � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 600 psi (41 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 600 psi (41 bar) Typical Burst Pressure: 2800 psi (193 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 26 lbs. (12 kg) T length– 28 lbs. (13 kg) U length– 30 lbs. (14 kg) Filter Element Collapse Pressure: 150 psid (10 bar)

Dimensional Drawings

Page 55: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.

Page 56: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

8900 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.30 0.14 0.12 0.09 0.06

13" 0.19 0.09 0.07 0.05 0.04

16" 0.14 0.07 0.05 0.04 0.03

8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.36 0.17 0.14 0.10 0.07

13" 0.21 0.10 0.08 0.06 0.04

16" 0.15 0.07 0.06 0.04 0.03

Assembly P/N: H 89 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 8900 (8900/10 Housing) F HC 8904 (8904/14 Housing) Table5 Table6 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Element/Head Options

Code Option*

00 'L' (standard element)

04 'L' (coreless element)

10 'T' (standard element)

14 'T' (coreless element)

"L" = L Head. "T" = T Head.

Page 57: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Table 3: Port Style Options

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c-code 61

Table 4: Port Size Options

Code Size

32 2"

40* 2-1/2"

* D ports only.

Table 5: Filter Element Options

Code ßx 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 6: Length Options*

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches.

Table 7: Bypass Valve Options

Code Description

A 25 psid

B 50 psid

Page 58: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation

W* Non-bypass

8* 25 psid with ABFV

9* 50 psid with ABFV

V* Non-bypass with ABFV

* ABFV - Anti-backflow valve, available for 'T' head units only: 8910/14.

Table 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Table 9: Auxiliary Ports

Code Auxiliary Ports

N Unmachined

B Both† sides

R* Right only†

L* Left only†

* Special order-contact factory. † Shipping plugs provided only.

Table 10: Ejector Spring Options

Code Description

N No ejector spring

S Ejector spring

Page 59: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Visit us on the Web at www.pall.com

Page 60: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9650/51/54 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 85 gpm (309 L/min) Pressures to 2000 psi (140 bar) Port sizes: 1" and 1-1/4"

Specifications

Features

� Optional Differential Pressure Devices � Ductile Iron Head � Ductile Iron Cover � Steel Tube � Ultipor® III Element � Full Flow Fast Response Bypass Valve

Maximum Acceptable Working Pressure: 2000 psi (140 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 2000 psi (140 bar) 1500 psi (103 bar) with K ports Typical Burst Pressure: 10,000 psi (690 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 24 lbs. (11 kg) U length– 35 lbs. (16 kg) Filter Element Collapse Pressure: 9604–150 psid (10 bar) 9650–290 psid (20 bar) 9651– 3000 psid (207 bar) Materials of Construction: Ductile iron head and cover steel tube

DImensional Drawings

Page 61: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 62: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 63: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 64: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 65: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9650/9604 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

16" 0.20 0.09 0.07 0.05 0.04

9651 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

16" 0.25 0.07

Assembly P/N: H 965 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 96 F Table2 Table5 Table6 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Page 66: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 2: ASSEMBLY OPTIONS

Housing Code Element Code Option

0 50 Standard element

1 51 High collapse element

4 04 Coreless element

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

K Manifold mount

TABLE 4: PORT SIZE OPTIONS

Code Size Style Availability

16 1" A, B

20 1-1/4" A,B,K

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP 3 5

DT 17 15

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

U 16

*Use code in second column for element part no. **Nominal length in inches.

Page 67: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid (9650, 9654)

W Non-bypass (9651 only)

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

Page 68: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9020/21/24 Series Filter Assemblies

Description

Featuring Coreless Element Technology

Flows to 20 gpm (75 L/min) Pressures to 3000 psi (207 bar) Port size: 3/4"

Specifications

Features

� Full Flow Fast Response Bypass Valve � Forged Aluminum Alloy Bowl (Anodized) � Optional Differential Pressure Devices � Extruded Aluminum Alloy Head (Anodized) � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 3000 psi (207 bar)

Fatigue Pressure Rating: (NFPA/T2.6 1 -1974 category 2/90) R length-1800 psi (124 bar) S length-1500 psi (103 bar)

Typical Burst Pressure: 15,000 psi (1035 bar)

Temperature Range: Nitrile seals-45°F to 225°F (-43°C to 107°C) Fluorocarbon seals-20°F to 250°F (-27°C to 121°C) 140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights: R length-3.7 lbs. (1.7 kg) S length-5 lbs. (2.3 kg)

Filter Element Collapse Pressure: 9020-290 psid (20 bar) 9021-3000 psid (207 bar) 9024-150 psid (10 bar)

Dimensional Drawings

Page 69: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Pressure Drop Information

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Page 70: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9020 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 1.90 0.82 0.54 0.35 0.21

8" 0.96 0.41 0.27 0.18 0.11

9021 Series Element P factor (psid/gpm)

Length DP DT

4" 2.71 0.68

8" 1.35 0.34

9024 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 1.12 0.48 0.31 0.21 0.13

Assembly P/N: H 902 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 902 F Table2 Table5 Table6 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Element Options

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

Page 71: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Table 3: Port Style Options

Code Port Style

A SAE J514 straight thread

L Manifold side mount*

K Manifold mount

*Contact factory for drawings.

Table 4: Port Size Options

Code Size

12 3/4"

TABLE 5: FILTER ELEMENT OPTIONS

CODE ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9021 series only.

Table 6: Length Options*

Assembly Code Element Code**

R*** 4

S 8

*Use code in second column for element part no. **Nominal length in inches ***Not available for 9024 series

Table 7: Bypass Valve Options

Page 72: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Contact Information

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Code Description

B 50 psid-9020/9024 only

W Non bypass 9021 only

Table 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

Page 73: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9720/24 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 125 gpm (475 L/min) Pressures to 4500 psi (310 bar) Port size: 1-1/2"

Specifications

Features

� Bleed Valve � Extra Long Threads � Full Flow Fast Response Bypass Valve � Ductile Head and Cap � O-Ring Seals � Heavy Wall Thickness Steel Tube � Ultipor® III Element � Optional Differential Pressure Devices � Drain Port and Plug � Flat Mounting Pad

Maximum Acceptable Working Pressure: 4500 psi (310 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3000 psi (207 bar) Typical Burst Pressure: 15,000 psi (1035 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: 1-high 61 lbs. (27.8 kg) 2-high 81 lbs. (37 kg) 3-high 101 lbs. (46 kg) Filter Element Collapse Pressure: 9700–290 psid (20 bar) 8904–150 psid (10 bar)

Dimensional Drawings

Page 74: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9700 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

Page 75: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Add a "1" suffix to specify a single length element for housing length option "2" or "3". Omit to specify multiple, single-length stacked elements. Note: Choose from the options in the following tables to compile the specific Product Number.

9" 0.26 0.12 0.10 0.08 0.05

18" 0.12 0.06 0.05 0.04 0.03

27" 0.08 0.04 0.03 0.02 0.02

8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.36 0.17 0.14 0.10 0.07

16" 0.15 0.07 0.06 0.04 0.03

26" 0.10 0.04 0.04 0.03 0.02

Assembly P/N: H 972 24 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 9720 (9720 Housing) F 8904 (9724 Housing) Table4 Table5 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

K Manifold mount

Page 76: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 5: Length Options*

Assembly Code Element Code**

1 9 (9720)

2 18 (9720)

3 27 (9720)

S 8 (9724)

U 16 (9724)

V 26 (9724)

* Use code in second column for element part no. ** Nominal length in inches. To stack 9" elements use Pall P/N HBS630-ID5 (reusable).

Table 6: Bypass Valve Options

Code Description

B 50 psid

C 50 psid bypass with reverse flow

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

Page 77: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Page 78: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9850/51/54 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 35 gpm (125 L/min) Pressures to 4061 psi (280 bar) Port sizes: 3/4" and 1"

Specifications

Features

� Optional Differential Pressure Devices � Ductile Iron Head � Forged Steel Bowl � Optional Drain Port and Plug � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 4061 psi (280 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3500 psi (241 bar) Typical Burst Pressure: 18,000 psi (1240 bar) Temperature Range: Nitrile seals -45°F to 225°F(-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 9.7 lbs. (4.4 kg) S length– 12.1 lbs. (5.5 kg) T length– 15.2 lbs. (6.9 kg) Filter Element Collapse Pressure: 9800– 290 psid (20 bar) 9801– 3000 psid (207 bar) 9804-150 psid (10 bar)

Dimensional Drawings

Page 79: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9800/9804 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

Page 80: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

*9800 only

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

4" * 1.83 0.72 0.56 0.40 0.26

8" 0.95 0.37 0.29 0.21 0.13

13" 0.58 0.23 0.18 0.13 0.08

9801 Series Element P factor (psid/gpm)

Length DP DT

4" 1.82 0.84

8" 0.90 0.39

13" 0.56 0.17

Assembly P/N: H 985 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 980 F Table2 Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

Page 81: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 4: PORT SIZE OPTIONS

Code Size Port Style

12 3/4" A

16 1" A, B

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9851 only.

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R*** 4

S 8

T 13

* Use code in second column for element part no. ** Nominal length in inches. *** 9850/51 only.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 9850/54 only

W Non-bypass- 9851 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE

Page 82: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

TABLE 9: SPECIAL OPTIONS

Code Description

L Indicator location (left or right when facing inlet port)

R Left is standard

TABLE 10: DRAIN PORT OPTIONS

Code Description

Omit No drain port

P Drain port

Page 83: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9800/01/04 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 55 gpm (200 L/min) Pressures to 6000 psi (414 bar) Port sizes: 3/4" and 1"

Specifications

Features

� Ductile Iron Head � O-Ring Seals � Forged Steel Bowl � Drain Port and Plug � Optional Differential Pressure Devices � Bleed Port and Plug � Full Flow Fast Response Bypass Valve � Ultipor® III Element

Maximum Acceptable Working Pressure: 6000 psi (414 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3500 psi (241 bar) Typical Burst Pressure: 20,000 psi (1380 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 9.7 lbs. (4.4 kg) S length– 12.4 lbs. (5.65 kg) T length– 15.7 lbs. (7.16 kg) Filter Element Collapse Pressure: 9800– 290 psid (20 bar) 9801– 3000 psid (207 bar) 9804– 150 psid (10 bar)

Dimensional Drawings

Page 84: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Page 85: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9800/9804 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4"* 1.83 0.72 0.56 0.40 0.26

8" 0.95 0.37 0.29 0.21 0.13

13" 0.58 0.23 0.18 0.13 0.08

*9800 only.

9801 Series Element P factor (psid/gpm)

Length DP DT

4" 1.82 0.84

8" 0.90 0.39

13" 0.56 0.17

Assembly P/N: H 980 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 980 F Table2 Table5 Table6 Table1

Table 1: Seal Options

Code Seals

Page 86: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

K Manifold mount

Table 4: Port Size Options

Code Size Port Style

12 3/4" A

16 1" A,B,D,E,K

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9801 only.

Page 87: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Table 6: Length Options*

Assembly Code Element Code**

R*** 4

S 8

T 13

* Use Code in second column for element part no. ** Nominal length in inches. ***9800/01 series only.

Table 7: Bypass Valve Options

Code Description

B 50 psid-9800/04 only

W Non-bypass- 9801 only

C 50 psid bypass with reverse flow (9800 only)

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

TABLE 9: MOUNTING BRACKET OPTIONS

Code Description

1 1 mounting bracket

2 2 mounting brackets

- No mounting brackets

Page 88: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 89: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9660/61/64 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 150 gpm (565 L/min) Pressures to 6000 psi (414 bar) Port sizes: 1", 1-1/4" and 1-1/2"

Specifications

Features

� Bleed Port and Plug � Multiple Port Options � Ductile Iron Head � Forged Steel Bowl � Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element � Drain Port and Plug

Maximum Acceptable Working Pressure: 6000 psi (414 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3000 psi (207 bar) Typical Burst Pressure: 20,000 psi (1380 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: R length– 22 lbs. (10 kg) S length– 27 lbs. (12.3 kg) T length– 33 lbs. (15 kg) U length– 44 lbs. (20 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 9604– 150 psid (10 bar)

Dimensional Drawings

Page 90: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Page 91: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9600/9604 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4"* 0.81 0.36 0.29 0.22 0.15

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

* 9600 only.

9601 Series Element P factor (psid/gpm)

Length DP DT

4" 1.04 0.25

8" 0.52 0.12

13" 0.32 0.08

16" 0.25 0.07

Assembly P/N: H 966 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 960 F Table2 Table5 Table6 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

Page 92: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

K Manifold mount (9660/61 only)

Table 4: Port Size Options

Code Size Style Availability

16 1" A,D,E

20 1-1/4" A,D,E

24 1-1/2" A,B,D,K

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9661 only.

Table 6: Length Options*

Assembly Code Element Code**

R*** 4

S 8

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches. *** Not available for 9664.

Page 93: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Table 7: Bypass Valve Options

Code Description

B 50 psid-9660/64 only

C 50 psid bypass with reverse flow (9660/64 only)

W Non-bypass- 9661 only

K Non-bypass with reverse flow-9661 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

TABLE 9: MOUNTING BRACKET OPTIONS

Code Description

1 1 mounting bracket

2 2 mounting brackets

- No mounting brackets

TABLE 10: SPECIAL OPTIONS

Code Description

Y411* Heavy duty ‘B’,‘C’ or ‘K’ valve for highly cyclic applications

Y151 3/4" mounting bolt holes for ‘K’ head (1/2" bolt holes standard)

* Not available for 9664

Page 94: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 95: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9900/01/04 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 250 gpm (910 L/min) Pressures to 6000 psi (414 bar) Port sizes: 1-1/2" and 2"

Specifications

Features

� Bleed Port and Plug � Multiple Port Options � Steel Tube � Ductile Iron Head � Optional Differential Pressure Devices � Full Flow Fast Response Bypass Valve � O-Ring Seals � Ultipor® III Element

Maximum Acceptable Working Pressure: 6000 psi (414 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 3000 psi (207 bar) Typical Burst Pressure: 15,000 psi (1035 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: T length– 80 lbs. (36.5 kg) V length– 108 lbs. (49.2 kg) X length– 134 lbs. (61.1 kg) Filter Element Collapse Pressure: 9400– 290 psid (20 bar) 9901– 3000 psid (207 bar) 9404– 150 psid (10 bar)

Dimensional Drawings

Page 96: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Page 97: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9400/9404 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

13" 0.19 0.09 0.07 0.05 0.04

26" 0.09 0.05 0.04 0.03 0.02

39" 0.06 0.03 0.02 0.02 0.01

9901 Series Element P factor (psid/gpm)

Length DP DT

13" 0.19 0.06

26" 0.10 0.03

39" 0.06 0.02

Assembly P/N: H 990 Note: For heavy duty valve (B,C,or K option) add Y128 to end of part number Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC F Table2 Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Element Code Rating

0 9400 290 psid (standard)

1 9901 3000 psid (high collapse)

4 9404 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Page 98: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Code Port Style

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

24 1-1/2"

32 2"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9901 only.

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

T 13

V 26

X 39

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 9900/04 only

Page 99: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

C 50 psid bypass with Reverse Flow-9900/04 only

W Non-bypass-9901 only

K Non-bypass with reverse flow-9901 only

N No element no flow- valve 9901 only

Valve options W,K,N require use of 3000 psid collapse element (series code ending in ‘l’).

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Page 100: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

4510/11/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 35 gpm (130L/min) Pressures to 6500 psi (450 bar) Port sizes: 3/4" and 1"

Specifications

Features

� Optional Differential Pressure Devices � Patented Sealing Interface - Positive sealing with standard O-rings � Forged Steel Bowl � Ductile Iron Head � Full Flow Fast Response Bypass Valve � Sampling or Bleed Port � Ultipor® III Element � Optional ¼" Drain Port

Maximum Acceptable Working Pressure: 6500 psi (450 bar)

Fatigue Pressure Rating: (NFPA/T2.6.1-1991 category B/90) 5800 psi (400 bar)-Stainless steel indicators required above 3000 psi (207 bar) RFP

Typical Burst Pressure: 23,000 psi (1600 bar)

Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights: R length - 15 lbs. (6.8 kg) S length - 18 lbs. (8.2 kg)

Filter Element Collapse Pressure: 9800-290 psid (20 bar) 9801-3000 psid (207 bar) 9804-150 psid (10 bar)

Dimensional Drawings

Page 101: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Pressure Drop Information

Page 102: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cST), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9800/9804 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4"* 1.83 0.72 0.56 0.40 0.26

8" 0.95 0.37 0.29 0.21 0.13 *9800 series only.

9801 Series Element P factor (psid/gpm)

Length DP

4" 1.82

8" 0.90

Assembly P/N: H 451 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 980 F Table2 Table5

Table6

Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

Page 103: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

12 3/4"

16 1"

TABLE 5: FILTER ELEMENT OPTIONS

Code �x 200 �x(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*4511 ONLY. *Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000 psi, stainless steel indicators are necessary. Designate with an 'H' in model Code (e.g., PH, LH, etc.).

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R*** 4

Page 104: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Contact Information

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation Visit us on the Web at www.pall.com

S 8

*Use Code in second column for element part no. **Nominal length in inches. ***Not available for 4514.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid - 4510/14 only

C 50 psid bypass with reverse flow-4510 only

W Non-bypass - 4511 only

K Non-bypass with reverse flow - 4511 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Page 105: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

4610/11/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 70 gpm (265 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1" and 1-1/4"

Specifications

Features

� Optional Differential Pressure Devices � Patented Sealing Interface - Positive sealing with standard O-rings � Forged Steel Bowl � Ductile Iron Head � Full Flow Fast Response Bypass Valve � Sampling or Bleed Port � Ultipor® III Element � Optional ¼" Drain Port

Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1991 category B/90) 5800 psi (400 bar) Stainless steel indicators required above 3000 psi (207 bar) RFP Typical Burst Pressure: 23,000 psi (1600 bar) Filter Element Collapse Pressure: 290 psid (20 bar) minimum per ISO 2941 Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 33 lbs. (15 kg) T length– 39 lbs. (17.7 kg) Filter Element Collapse Pressure: 9100–290 psid (20 bar) 9101–3000 psid (207 bar) 9104–150 psid (10 bar)

Dimensional Drawings

Page 106: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Page 107: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9100/9104 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.53 0.25 0.21 0.16 0.11

13" 0.32 0.14 0.11 0.09 0.06

9101 Series Element P factor (psid/gpm)

Length DP DT

8" 0.55 0.23

13" 0.34 0.16

Assembly P/N: H 461 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 910 F Table2 Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Page 108: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

16 1"

20 1-1/4"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*4611 only *Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model Code (e.g., PH, DH, etc.).

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

* Use Code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 4610/14 only

Page 109: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

C 50 psid bypass with reverse flow-4610 only

W Non-bypass- 4611 only

K Non-bypass with reverse flow-4611 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

Page 110: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

4710/11/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 130 gpm (490 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1-1/4" and 1-1/2"

Specifications

Features

� Optional Differential Pressure Devices � Patented Sealing Interface - Positive sealing with standard O-rings � Forged Steel Bowl � Ductile Iron Head � Full Flow Fast Response Bypass Valve � Sampling or Bleed Port � Ultipor® III Element � Optional ¼" Drain Port

Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1991 category B/90) 5800 psi (400 bar) Stainless steel indicators required above 3000 psi (207 bar) RFP Typical Burst Pressure: 23,000 psi (1600 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: T length- 54 lbs. (24.5 kg) U length- 60 lbs. (27 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 4704– 150 psid (10 bar)

Dimensional Drawings

Page 111: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Page 112: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

13" 0.32 0.08

16" 0.25 0.07

Assembly P/N: H 471 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC F Table2 Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid (high collapse)

4 4704 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

Page 113: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

20 1-1/4"

24 1-1/2"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*4711 only. *Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model code (e.g., PH, DH, etc.).

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 4710/14 only

C 50 psid bypass with reverse flow-4710 only

W Non-bypass- 4711 only

K Non-bypass with reverse flow-4711 only

Page 114: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

Page 115: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8340/70 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 400 gpm (1500 L/min) Pressures to 400 psi (28 bar) Port sizes: 3" and 4"

Specifications

Features

� 8310 or 8314 Assembly (Ultipor® III Element) � Commuter Valve - Built in Design Requires No External Lines. Use to Equalize Pressure During

Element Change � Duplex Check Valve at Outlet - Seals Off-Line Filter to Prevent Backflow; Simplifies Element Change � Ball Type Open Center Transfer Valve - Ensures Continuous Filtration While Changing Elements

Without Shutting Down the Machine

Maximum Acceptable Working Pressure: 400 psi (28 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 330 psi (23 bar) Typical Burst Pressure: 2100 psi (145 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights:

Filter Element Collapse Pressure: 8310–100 psid (7 bar) 8314–150 psid (10 bar) Materials of Construction: Head, cover, handle, tube, manifold and valve bodies – aluminum alloy. Center post, core, and internal valve parts – coated carbon steel. Dimensional Drawings

8340/8370: U length–165 lbs. (75 kg)X length– 260 lbs. (118 kg)

8342/8372: X length– 475 lbs. (215 kg)8343/8373: X length– 680 lbs. (310 kg)8344/8374: X length– 890 lbs. (405 kg)

Page 116: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor* Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.

Bypass valve pressure drops are directly proportional to specific gravity.

8310/14 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.089 0.047 0.040 0.031 0.022

39" 0.034 0.018 0.015 0.012 0.008

* Based on flow through each housing/element. Divide total flow by number of housings per side to determine flow per each housing/element.

Assembly P/N: H 83 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 83 F Table2 Table5 Table6 Table1

Page 117: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code* Description

4 10 Conventional

7 14 Coreless

*Nominal length in inches. Use code in second column for element part no.

TABLE 3: QUANTITY OF HOUSINGS

Code Description

0 2 Housings (1/side)

2 4 Housings (2/side)

3 6 Housings (3/side)

4 8 Housings (4/side)

TABLE 4: PORT SIZE OPTIONS

Code Size

D48 3" flange SAE J518c-Code 61

D64 4" flange SAE J518c-Code 61

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Page 118: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

U 16

X 39

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

Y Non-bypass with 16 psid indicator

N Non-bypass with 35 psid indicator

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Electrical indicators in base only.

Page 119: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 120: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8384/85 Series Service Bypass Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 200 gpm (760 L/min) Pressures to 400 psi (28 bar) Port sizes: 2" and 2-1/2" SAE split flange

Specifications

Features

� Optional Differential Pressure Device � Changeover Handle with Latching Pin Mechanism � 8310 or 8314 Series (Ultipor® III Element)

Maximum Acceptable Working Pressure: 400 psig (28 bar) Fatigue Pressure Rating: 330 psig (23 bar) (107 cycles per NFPA T2.6.1-1974) Typical Burst Pressure: 2100 psig (145 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 8314–150 psid (10 bar) 8310–100 psid (7 bar) Materials of Construction: Head, cover, handle, tube, manifold and valve bodies – aluminum alloy. Center post, core, and internal valve parts – coated carbon steel.

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Page 121: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

8310/14 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.089 0.047 0.040 0.031 0.022

39" 0.034 0.018 0.015 0.012 0.008

Assembly P/N: H 838 D Table1 Table2 Table3 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 831 F Table4 Table5 Table6 Table1

Table 1: Seal Options

Code Seals

H Buna N

Z Fluorocarbon

Table 2: Housing Series Options

Code Element

4 Coreless (use Code '4' in table 4)

5 Standard (use Code '0' in table 4)

Table 3: Port Size Options

Code Size

32 2" SAE flange

40 2-1/2" SAE flange

Page 122: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

*Caution: If non-bypass configuration is selected, do not use in systems with surge pressures over 90 psig (8385) or 120 psig (8384), in order to avoid possible filter element collapse and containment passing

downstream.

Table 4: Element Series Options

Code Options

4 8314 series coreless filter elements

0 8310 series filter elements (with core)

Table 5: Filter Element Options

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 6: Length Options*

Assembly Code Element Code** Dry Weight Maximum

U 16 61 lb.

X 39 82 lb.

* Use code in second column for element part no. ** Nominal length in inches.

Table 7: Bypass Valve Options

Code Description

A 25 psid ± 3 psid bypass

B 50 ± 5 psid bypass

Y Without bypass* 16 psid P indicator

N Without bypass* 35 psid P indicator

1 Without bypass* with P device F or B

Table 8: Differential Pressure Device Options

Page 123: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Code Description Location

B Plug in place of P device Both

P Visual indicator with thermal lockout Cover

D 'P' type with no thermal lockout Cover

L Electrical switch (SPDT) with 6" leads Base

S Electrical switch with MS receptacle Base

T 'L' type with DIN connector Base

M 'T' type with wiring cap Base

2 'P' and 'L' As above

3 'P' and 'S' As above

Table 9: Handle Orientation Options

Code Handle Orientation

L Handle on left side when facing inlet port

R Handle on right side when facing inlet port

Page 124: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

8670/71/74 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 50 gpm (190 L/min) Pressures to 1200 psi (80 bar) Port sizes: 1-1/4"

Specifications

Features

� Non-Welded Construction (Gray Iron Head) � Vent Plugs � Changeover Handle with Latching Pin Mechanism � Filter Element Change Instruction Plate � Forged Steel Bowls � Commuter Valve (To Repressurize Idle Side After Element Change) � O-Ring Seals Throughout � Filter "In-Service" Pointer � Differential Pressure Device (Optional) � Ultipor® III Element � Drain Plug

Maximum Acceptable Working Pressure: 1200 psi (80 bar) Typical Burst Pressure: 5500 psi (380 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 65 lbs. (29 kg) T length– 75 lbs. (33.5 kg) U length– 85 lbs. (38 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 4704–150 psid (10 bar)

Page 125: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.

Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.

Page 126: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

13" 0.32 0.08

16" 0.25 0.07

Assembly P/N: H 867 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC F Table2 Table4 Table5 Table1

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Element Options

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid (high collapse)

4 9604 150 psid (coreless)

Page 127: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Table 3: Port Options

Code Description

A20 1-1/4" SAE J514 straight thread

D20 1-1/4" Flange SAE J518c-code 61

Table 4: Filter Element Options

Code ßX 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

* 8671 only.

Table 5: Length Options*

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches.

Table 6: Bypass Valve Options

Code Description

A* 25 psid bypass 8670/8674 only

B 50 psid bypass 8670/8674 only

W Non-bypass 8670 to 120 psi max. 8671 to 1200 psi max. Not available for 8674.

* A valve-25 gpm max flow.

Table 7: Differential Pressure Device Options

Page 128: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

Page 129: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

9685 Series Service Bypass Filter Assemblies

Description

Flows to 65 gpm (250 L/min) Pressures to 6000 psi (400 bar) Port sizes: 1-1/4"

Specifications

Features

� Ductile Iron Head � Commuter Valve (To Repressurize After Element Change) � Bleed Valve � O-Ring Seals � Ultipor® III Element � Drain Port and Plug � Optional Differential Pressure Device � Stainless Steel Bypass Valve with Nylon Poppet (Not Shown) � Stainless Steel Ball Valve with PTFE Seats (Not Shown) � Change Over Handle with Latching Pin Mechanism � All Non-Stainless Steel Parts Corrosion Protected

Maximum Acceptable Working Pressure: 6000 psi (400 bar) Fatigue Pressure Rating: 4000 psi (275 bar) Typical Burst Pressure: 24,360 psi (1680 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 45 lbs. (21 kg) T length– 50 lbs. (23 kg) U length– 55 lbs. (25 kg) Filter Element Collapse Pressure: 9600– 290 psid (20 bar)

Dimensional Drawings

Page 130: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific

gravity.

9600 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

Assembly P/N: H 9685 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 9600 F Table4 Table5 Table1

Page 131: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 3: PORT SIZE OPTIONS

Code Size Style Availability

20 1-1/4" All

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

Page 132: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

U 16

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

L 58 psid

TABLE 7: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

All differential pressure devices for the 9685 set at 44 psid.

Page 133: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

4740/41/44 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 90 gpm (340 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1-1/2"

Specifications

Features

� Open Center Transfer Valve 3-Way Ball Type � Low Torque Handle � O-Ring Seals � Optional Differential Pressure Devices � Bleed Valves � Commuter Valve � Ultipor® III Element

Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: 5800 psi (400 bar) with stainless steel indicator Typical Burst Pressure: 23,200 psi (1600 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 114 lbs. (52 kg) T length– 120 lbs. (55 kg) U length– 131 lbs. (60 kg) Filter Element Collapse Pressure: 9600-290 psid (20 bar) 9601-3000 psid (207 bar) 4704-150 psid (10 bar) Materials: –Ductile iron head –Forged steel bowls

Dimensional Drawings

Page 134: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.

Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.

Bypass valve pressure drops are directly proportional to specific gravity.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

Page 135: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

13" 0.32 0.08

16" 0.25 0.07

Assembly P/N: H 474 24 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC F Table2 Table4 Table5 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid (high collapse)

4 4704 150 psid (coreless)

TABLE 3: PORT OPTIONS

Code Port Style

A SAE J514 straight thread

D* Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

*D ports rated at 3000 psi (207 bar).

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

Page 136: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

KT 25 22

DP* 3 5

DT* 17 15

* 4741 only.

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

B 50 psid-4740/44 only

W Non-bypass-4741 only

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

Note: Above indicators fatigue rated at 3000 psi. For cyclic pressure above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model code (e.g., PH, DH, etc.).

Page 137: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 138: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

6220 Series Filter Assembies

Description

Flows to 40 gpm (150 L/min) Pressures to 150 psi (10 bar) Port size: 1"

Specifications

Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Maximum Operating Pressure: 150 psi (10 bar) Typical Burst Pressure: 1200 psi (83 bar) Filter Element Collapse Pressure: 290 psid (20 bar) minimum Fluid Compatibility: Petroleum oils, water glycols, water-oil emulsions, and HWCF. Fluorocarbon seals required for industrial phosphate esters, diesters, and specified synthetics. 140°F (60°C) max in water containing fluids. Materials of Construction: Aluminum alloy head, cover and canister

Dimensional Drawings

Page 139: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 140: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

6200 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

Page 141: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

4" 1.1 0.56 0.30 0.19 0.14

8" 0.53 0.27 0.15 0.10 0.07

Assembly P/N: H 6220 A 16 B Table1 Table2 Table3 Table4

Element P/N: HC 6200 F Table2 Table3 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 3: LENGTH OPTIONS*

Assembly Code Element Code** Assembly Dry Wt. (lbs.)

R 4 2.2

S 8 2.4

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 4: P DEVICE OPTIONS

Code P Option H Dim.

G Pressure gauge (0-150 psi) 1.25" (32 mm)

B Plugged 1/8" NPT gauge port supplied 0.5" (12 mm)

8 Electrical absolute pressure switch. Electrical ratings suffix 24 volts DC–24 DC 220 volts AC-220 AC

2.7" (69 mm)

Page 142: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 143: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

6300 Series Filter Assemblies

Description

Flows to 120 gpm (450 L/min) Pressures to 250 psi (17 bar) Port sizes: 1-1/4" and 1-1/2"

Specifications

Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 250 psi (17 bar) Typical Burst Pressure: 1200 psi (83 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 18.5 lbs. (8.4 kg) T length– 20.0 lbs. (9.1 kg) U length– 23.5 lbs. (10.7 kg) V length– 27.0 lbs. (12.3 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings

Page 144: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 145: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 146: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.

Page 147: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

6300 Series Element P factor (psid/gpm)

Length DP DN DS DT

8" 0.29 0.18 0.13 0.09

13" 0.19 0.10 0.08 0.07

16" 0.14 0.08 0.06 0.05

26" 0.11 0.05 0.04 0.03

Assembly P/N: H 6300 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 6300F Table4 Table5 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

TABLE 3: INLET PORT SIZE OPTIONS

Code Size

20 1-1/4"

24 1-1/2"

Page 148: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

DP 3 5

DN 6 7

DS 12 12

DT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

U 16

V 26

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

Page 149: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

BL Plug in place of indicator

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Indicator and switch pressure settings. 16 psid with "A" and "8" bypass valve. 35 psid with "W," "V," "B," and "9" option.

TABLE 8: SECONDARY PORT OPTIONS

Code Port Option Port Size

S Port machined 1"

N Non-machined -

Port opposite main inlet in style consistent with main inlet port (see Table 2) except that "A" style secondary port is used with "D" style main inlet port.

TABLE 9: AUXILIARY PORT OPTIONS

Code Port Option Port Size

R Right side* 3/4"

L Left side* 3/4"

B Both 3/4"

N Non-machined -

* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2), except that "A" style auxiliary port(s) is used with "D" style main inlet port.

Page 150: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

6400 Series Filter Assemblies

Description

Flows to 200 gpm (755 L/min) Pressures to 250 psi (17 bar) Port sizes: 1-1/2" and 2"

Specifications

Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 250 psi (17 bar) Typical Burst Pressure: 1200 psi (83 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: S length– 22.5 lbs. (10.2 kg) T length– 23.7 lbs. (10.8 kg) U length– 25.0 lbs. (11.3 kg) V length– 31.0 lbs. (14.1 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings

Page 151: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 152: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 153: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.

Page 154: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

6400 Series Element P factor(psid/gpm)

Length DP DN DS DT

8" 0.26 0.16 0.12 0.08

13" 0.17 0.09 0.07 0.06

16" 0.13 0.07 0.05 0.04

26" 0.10 0.05 0.04 0.03

Assembly P/N: H 6400 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 6400F Table4 Table5 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

TABLE 3: INLET PORT SIZE OPTIONS

Code Size

20 1-1/4"

24 1-1/2"

Page 155: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 4: FILTER Element OPTIONS

Code ßx 200 ßx(c)=1000

DP 3 5

DN 6 7

DS 12 12

DT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

U 16

V 26

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

Page 156: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

BL Plug in place of indicator

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Indicator and switch pressure settings. 16 psid with "A"and "8" bypass valve. 35 psid with "W," "V," "B," and "9" option.

TABLE 8: SECONDARY PORT OPTIONS

Code Port Option Port Size

S Port machined 1-1/4"

N Non-machined -

Port opposite main inlet in style consistent with main inlet port (see Table 2).

TABLE 9: AUXILIARY PORT OPTIONS

Code Port Option Port Size

R Right side* 1"

L Left side* 1"

B Both 1"

N Non-machined -

* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2), except that "A" style auxiliary port(s) is used with "D" style main inlet port.

Page 157: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

6500 Series Filter Assemblies

Description

Flows to 300 gpm (1135 L/min) Pressures to 250 psi (17 bar) Port sizes: 2" and 2-1/2"

Specifications

Maximum Acceptable Working Pressure: 250 psi (17 bar) Fatigue Pressure Rating: (NFPA/T2.6.1-1974 category 2/90) 250 psi (17 bar) Typical Burst Pressure: 1200 psi (83 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Dry Weights: T length– 26.0 lbs. (11.8 kg) U length– 30.0 lbs. (13.6 kg) V length– 35.5 lbs. (16.1 kg) Filter Element Collapse Pressure: 150 psid (10 bar) Caution: 120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings

Page 158: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 159: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE
Page 160: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.

Page 161: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

6500 Series Element P factor (psid/gpm)

Length DP DN DS DT

13" 0.14 0.08 0.06 0.05

16" 0.11 0.06 0.04 0.04

26" 0.08 0.04 0.03 0.02

Assembly P/N: H 6500 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 6500F Table4 Table5 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

TABLE 3: INLET PORT SIZE OPTIONS

Code Size

32 2"

40 2-1/2"

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

Page 162: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

DP 3 5

DN 6 7

DS 12 12

DT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

T 13

U 16

V 26

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

BL Plug in place of indicator

Page 163: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Indicator and switch pressure settings 16 psid with "A"and "8" bypass valve 35 psid with "W," "V," "B," and "9" option.

TABLE 8: SECONDARY PORT OPTIONS

Code Port Option Port Size

S Port machined 1-1/2"

N Non-machined -

Port opposite main inlet in style consistent with main inlet port (see Table 2).

TABLE 9: AUXILIARY PORT OPTIONS

Code Port Option Port Size

R Right side* 1-1/4"

L Left side* 1-1/4"

B Both 1-1/4"

N Non-machined -

* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2).

Page 164: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

301/381 Series ASME Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 150 gpm (570 lpm), 301 Series; 300 gpm (1135 lpm), 381 Series Pressures to 675 psig (46.5 bar) Port Sizes: 2", 3", and 4" ANSI Flange Connections

Specifications

Maximum Acceptable Working Pressure: Class 150: 260 psig (18 bar); Class 300: 675 psig (46.5 bar) at 200°F (93°C) Temperature Range: -20°F to 200°F (-29°C to 93°C); 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 150 psid (10 bar) Hydrostatic Test Pressure: Class 150: 390 psig (26.9 bar) Class 300: 1013 psig (69.8 bar) Materials of Construction: Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless steel 304L valve ball and stem on “D” duplex model Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve body, valve ball, and stem on “D” duplex model Finish: Interior finish: coated with rust preventative Permanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.

Dimensional Drawings

Page 165: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Dimensions (301 Series)

Port Size

‘A’ Simplex Only

‘B’ Duplex Only

‘C’ Duplex Only

‘D’ ‘E’ ‘F’ Duplex Only

‘G’ ‘L’ V-Length

‘L’ X-Length

JO2 7.88 3.94 19.69 6.00 8.66 5.12 6.63 46.06 59.06

J03 7.88 5.12 20.87 6.00 11.42 6.89 6.63 46.06 59.06

Dimensions (381 Series)

Port Size

‘A’ Simplex Only

‘B’ Duplex Only

‘C’ Duplex Only

‘D’ ‘E’ ‘F’ Duplex Only

‘G’ ‘L’ V-Length

‘L’ X-Length

JO3 10.00 5.12 25.12 8.00 11.42 6.89 8.63 N/A 61.75

J04 10.00 5.90 25.90 6.00 13.78 7.28 8.63 N/A 61.75

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.

Page 166: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Maximum Clean Element Pressure Drop for Bypass Valves Calculated clean element pressure drop should not exceed the values listed in the table for the selected bypass valve option.

Housing Pressure drop is directly proportional to specific gravity. 301 Series with 8904 Elements

381 Series with 8314 Elements

8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

26" 0.10 0.044 0.037 0.028 0.019

39" 0.062 0.029 0.024 0.018 0.013

8314 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

39" 0.034 0.018 0.015 0.012 0.008

Bypass ‘E’ ‘F’ ‘D’ ‘A’ ‘B’ ‘W’

Page 167: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

Option (5 psid) (12 psid) (18 psid) (25 psid) (50 psid) (non-bypass)

Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P

Assembly P/N: H 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Replacement Element P/N: HC 8904F

Table5 Table6 Table1 HC 8314F

Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: HOUSING OPTION*

Code Option

01 8904 element

81 8314 element

*Housings accept a single element.

TABLE 3: HOUSING STYLE OPTIONS

Code Style

S Simplex - ports on same side

D Duplex

TABLE 4: PORT OPTIONS

Code Port Availability

J02 2" ANSI B16.5 class 150 flanges 301 series

J03 3" ANSI B16.5 class 150 flanges 301 and 381 series

J04 4" ANSI B16.5 class 150 flanges 381 series

N02 2" ANSI B16.5 class 300 flanges 301 series

N03 3" ANSI B16.5 class 300 flanges 301 and 381 series

N04 4" ANSI B16.5 class 300 flanges 381 series

Page 168: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code** Availability

V 26 301 series only

X 39 301 and 381 series

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Cracking Pressure

A 25 psid

B 50 psid

D 18 psid

E 5 psid

F 12 psid

W Non-bypass

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

O No indicator

B Bleed plug and seal in place of indicator

P Visual indicator with thermal lockout

S Electrical switch with MS receptacle

L Electrical switch with 6" leads

V Electrical/visual indicator

TABLE 9: HOUSING MATERIAL OPTIONS

Code Option

Page 169: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

7 Carbon steel

9 304L stainless steel

Page 170: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

307/387 Series ASME Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 900 gpm (3406 lpm), 307 Series; 1500 gpm (5678 lpm), 387 Series Pressures to 675 psig (46.5 bar) Port Sizes: 4" and 6" ANSI Flange Connections

Specifications

Maximum Acceptable Working Pressure: Class 150: 260 psig (18 bar); Class 300: 675 psig (46.5 bar) at 200°F (93°C) Temperature Range: -20°F to 200°F (-29°C to 93°C); 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 150 psid (10 bar) Hydrostatic Test Pressure: Class 150: 390 psig (26.9 bar) Class 300: 1013 psig (69.8 bar) Materials of Construction: Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless steel 304L valve ball and stem on “D” duplex model Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve body, valve ball, and stem on “D” duplex model Finish: Interior finish: coated with rust preventative Permanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.

Dimensional Drawings

Page 171: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Dimensions (307 Series)

Port Size

‘A’ Simplex Only

‘B’ Duplex Only

‘C’ Duplex Only

‘D’ ‘E’ ‘F’ Duplex Only

‘G’ ‘L’ V-Length

‘L’ X-Length

JO4 11.85 5.90 29.60 8.00 13.78 7.28 14.00 50.06 63.06

J06 11.85 11.81 35.50 6.50 23.62 8.46 14.00 59.90 72.90

Dimensions (387 Series)

Port Size

‘A’ Simplex Only

‘B’ Duplex Only

‘C’ Duplex Only

‘D’ ‘E’ ‘F’ Duplex Only

‘G’ ‘L’ V-Length

‘L’ X-Length

JO6 17.85 11.81 47.50 8.00 23.62 8.46 20.00 N/A 72.75

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.

Page 172: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

*Factors listed above have been adjusted to represent the total number of elements per housing.

Housing Pressure drop is directly proportional to specific gravity. 307 Series with 8904 Elements

387 Series with 8314 Elements

*8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

26" 0.014 0.006 0.005 0.004 0.003

39" 0.009 0.004 0.003 0.003 0.002

*8314 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

39" 0.0049 0.0026 0.0021 0.0017 0.0011

Page 173: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Maximum Clean Element Pressure Drop for Bypass Valves Calculated clean element pressure drop should not exceed the values listed in the table for the selected bypass valve option.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

Bypass Option

‘E’ (5 psid)

‘F’ (12 psid)

‘D’ (18 psid)

‘A’ (25 psid)

‘B’ (50 psid)

‘W’ (non-bypass)

Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P

Assembly P/N: H 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Replacement Element P/N: HC 8904F

Table5 Table6 Table1 HC 8314F

Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: HOUSING OPTION*

Code Option

07 8904 element

87 8314 element

*Housings accept 7 elements.

TABLE 3: HOUSING STYLE OPTIONS

Code Style

S Simplex - ports on same side

D Duplex

TABLE 4: PORT OPTIONS

Page 174: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Code Port Availability

J04 4" ANSI B16.5 class 150 flanges 307 series

J06 6" ANSI B16.5 class 150 flanges 307 and 387 series

N04 4" ANSI B16.5 class 300 flanges 307 series

N06 6" ANSI B16.5 class 300 flanges 307 and 387 series

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code** Availability

V 26 307 series only

X 39 307 and 387 series

* Use Code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Cracking Pressure

A 25 psid

B 50 psid

D 18 psid

E 5 psid

F 12 psid

W Non-bypass

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

O No indicator

B Bleed plug and seal in place of indicator

Page 175: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

P Visual indicator with thermal lockout

S Electrical switch with MS receptacle

L Electrical switch with 6" leads

V Electrical/visual indicator

TABLE 9: HOUSING MATERIAL OPTIONS

Code Option

7 Carbon steel

9 304L stainless steel

Page 176: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

303/383 Series ASME Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 400 gpm (1510 lpm), 303 Series; 700 gpm (2650 lpm), 383 Series Pressures to 675 psig (46.5 bar) Port Sizes: 2", 3", 4" and 6" ANSI Flange Connections

Specifications

Maximum Acceptable Working Pressure: Class 150: 260 psig (18 bar); Class 300: 675 psig (46.5 bar) at 200°F (93°C) Temperature Range: -20°F to 200°F (-29°C to 93°C); 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 150 psid (10 bar) Hydrostatic Test Pressure: Class 150: 390 psig (26.9 bar) Class 300: 1013 psig (69.8 bar) Materials of Construction: Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless steel 304L valve ball and stem on “D” duplex model Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve body, valve ball, and stem on “D” duplex model Finish: Interior finish: coated with rust preventative Permanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.

Dimensional Drawings

Page 177: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Dimensions (303 Series)

Port Size

‘A’ Simplex Only

‘B’ Duplex Only

‘C’ Duplex Only

‘D’ ‘E’ ‘F’ Duplex Only

‘G’ ‘L’ V-Length

‘L’ X-Length

JO2 10.00 3.94 23.94 8.00 8.66 5.12 10.75 50.06 63.06

J03 10.00 5.12 25.12 8.00 11.42 6.89 10.75 50.06 63.06

J04 10.00 5.90 25.90 8.00 13.78 7.28 10.75 50.06 63.06

Dimensions (383 Series)

Port Size

‘A’ Simplex Only

‘B’ Duplex Only

‘C’ Duplex Only

‘D’ ‘E’ ‘F’ Duplex Only

‘G’ ‘L’ V-Length

‘L’ X-Length

JO4 14.10 5.90 34.20 8.00 13.78 7.28 16.00 N/A 61.75

J06 14.10 11.81 40.00 8.00 23.62 8.46 16.00 N/A 61.75

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.

Page 178: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Housing Pressure drop is directly proportional to specific gravity. 303 Series with 8904 Elements

383 Series with 8314 Elements

*8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

26" 0.033 0.015 0.012 0.009 0.006

39" 0.021 0.010 0.008 0.006 0.004

*8314 Series Element P factor (psid/gpm)

Page 179: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Maximum Clean Element Pressure Drop for Bypass Valves Calculated clean element pressure drop should not exceed the values listed in the table for the selected bypass valve option.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

Length KZ KP KN KS KT

39" 0.011 0.006 0.005 0.004 0.003

*Factors listed above have been adjusted to represent the total number of elements per housing.

Bypass Option

‘E’ (5 psid)

‘F’ (12 psid)

‘D’ (18 psid)

‘A’ (25 psid)

‘B’ (50 psid)

‘W’ (non-bypass)

Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P

Assembly P/N: H 3 Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Replacement Element P/N: HC 8904F

Table5 Table6 Table1 HC 8314F

Table5 Table6 Table1

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: HOUSING OPTION*

Code Option

03 8904 element

83 8314 element

*Housings accept 3 elements.

TABLE 3: HOUSING STYLE OPTIONS

Code Style

S Simplex - ports on same side

D Duplex

Page 180: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 4: PORT OPTIONS

Code Port Availability

J02 2" ANSI B16.5 class 150 flanges 303 series

J03 3" ANSI B16.5 class 150 flanges 303 series

J04 4" ANSI B16.5 class 150 flanges 303 and 383 series

J06 6" ANSI B16.5 class 150 flanges 383 series

N02 2" ANSI B16.5 class 300 flanges 303 series

N03 3" ANSI B16.5 class 300 flanges 303 series

N04 4" ANSI B16.5 class 300 flanges 303 and 383 series

N06 6" ANSI B16.5 class 300 flanges 383 series

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code** Availability

V 26 303 series only

X 39 303 and 383 series

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Cracking Pressure

A 25 psid

Page 181: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

B 50 psid

D 18 psid

E 5 psid

F 12 psid

W Non-bypass

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

O No indicator

B Bleed plug and seal in place of indicator

P Visual indicator with thermal lockout

S Electrical switch with MS receptacle

L Electrical switch with 6" leads

V Electrical/visual indicator

TABLE 9: HOUSING MATERIAL OPTIONS

Code Option

7 Carbon steel

9 304L stainless steel

Page 182: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

2544 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 120 gpm (454 L/min) Pressures to 500 psi (34.5 bar) Port sizes: 1-1/4" and 1-1/2"

Specifications

Maximum Acceptable Working Pressure: 500 psi (34.5 bar) Bypass Valve: 25 psid (1.724 bar) Seals: Nitrile–Compatible with petroleum oils, water-oil emulsions and water-glycol Temperature Range: -45°F to 225°F (-43°C to 107°C) Filter Element Collapse Pressure: 150 psid (10 bar) Materials: – Aluminum head and nipple – Aluminum and steel bypass valve – Carbon steel canister and core assembly

Dimensional Drawings

Page 183: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.

Housing Pressure drop is directly proportional to specific gravity.

Page 184: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Element Pressure Drop Factor Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Note: Choose from the options in the following tables to compile the specific Product Number.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G. Bypass valve pressure drops are directly proportional to specific gravity.

2544 Series Element P factor (psid/gpm)

Length KP KN KS KT

9" 0.12 0.08 0.06 0.05

19" 0.06 0.04 0.03 0.02

Assembly P/N: HH 2544 A Table1 Table2 Table3 Table4 Table5 Table6

Element P/N: HC 2544F H Table2 Table3

TABLE 1: PORT OPTIONS

Code Port Option

A20 1-1/4" SAE straight thread O-ring boss per SAE J514H

A24 1-1/2" SAE straight thread O-ring boss per SAE J514H

B20 1-1/4" NPT

B24 1-1/2" NPT

Page 185: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

TABLE 2: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 3: LENGTH OPTIONS*

Assembly Code Element Code**

S 9

U 19

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 4: INDICATOR OPTIONS

Code Device

G Pressure gauge (25 psi), other port plugged (1/8" NPT)

8 Pressure switch (15 psi) N.O. S.P.S.T. screw terminals, other port plugged (1/8" NPT)

2 Pressure gauge (25 psi) and pressure switch (15 psi) N.O. S.P.S.T. screw terminals

B Port plugs (1/8" NPT)

TABLE 5: SECONDARY PORT OPTIONS

Code Description

OMIT No secondary port

20* 1-1/4" port (same port style as primary port)

* Available only with A24 and B24 primary ports.

Page 186: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

TABLE 6: OUTLET OPTIONS

Code Description

OMIT 1-5/8" discharge

D Diffuser with adapter

Page 187: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

4750/51/54 Series Filter Assemblies

Description

Featuring Coreless Element Technology Flows to 90 gpm (340 L/min) Pressures to 6500 psi (450 bar) Port sizes: 1-1/2"

Specifications

Features

� Low Torque Handle � Commuter Valve � Optional Differential Pressure Devices � Bleed Valves � O-Ring Seals � Ultipor® III Element � Open Center Transfer Valve 3-Way Ball Type

Maximum Acceptable Working Pressure: 6500 psi (450 bar) Fatigue Pressure Rating: 5800 psi (400 bar) with stainless steel indicator Typical Burst Pressure: 23,200 psi (1600 bar) Temperature Range: Nitrile seals -45°F to 225°F (-43°C to 107°C) Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids Filter Element Collapse Pressure: 9600– 290 psid (20 bar) 9601– 3000 psid (207 bar) 4704– 150 psid (10 bar) Materials: –Ductile iron head –Forged steel bowls

Dimensional Drawings

Page 188: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Performance

Element Pressure Drop Factor. Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

Ordering Information

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G. Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.

Bypass valve pressure drops are directly proportional to specific gravity.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

13" 0.32 0.08

16" 0.25 0.07

Assembly P/N: H 475 24 Table1 Table2 Table3 Table4 Table5 Table6 Table7

Page 189: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid (high collapse)

4 4704 150 psid (coreless)

TABLE 3: PORT OPTIONS

Code Port Style

A SAE J514 straight thread

D* Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

*D ports rated at 3000 psi (207 bar).

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

* 4751 only.

TABLE 5: LENGTH OPTIONS*

Page 190: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no. ** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

B 50 psid-4750/54 only

W Non-bypass-4751 only

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

Note: Above indicators fatigue rated at 3000 psi. For cyclic pressure above 3000 psi, stainless steel indicators are necessary. Designate with an ‘H’ in model code (e.g., PH, DH, etc.).

Page 191: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Ultipleat SRT Filter Assemblies

Description

Ordering Information

© Copyright Pall Corporation Visit us on the Web at www.pall.com

Page 192: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Data Sheet IM2035EN

2035 Series High Pressure Filter Assemblies

Features• High collapse 4500 psid (310 bard) filter element using

Rigimesh® stainless steel medium

• Flows to 38 lpm (10 gpm)

• Port sizes: 3⁄8" NPT, 1⁄2" NPT

Notes and Specifications

Maximum working pressure:6,000 psi (413 bar)

Typical burst pressure: min. 24,000 psi (1655 bar)

Temperature rating:-10°F (-23°C) to 225°F (107°C)

Materials of Construction:Head and Body: Stainless SteelSeal material: PTFE encapsulated fluorocarbon

(Nitrile and Chloroprene alsoavailable)

Filter elementcollapse pressure: 4500 psid (310 bard)Elementconstruction: Rigimesh all stainless steel (no resin

binders) medium, stainless steel end caps

Seal Material: Chloroprene, Nitrile, PTFE encapsulated fluorocarbon

Flow (gpm)

Flow (lpm)

0 4 8 12 16

∆P(p

sid)

50

40

30

20

10

0

0 15 30 45 60

2.8

1.4

0 ∆P(b

ar)

3/8˝ port

1/2˝ port

Flow (gpm)

Flow (lpm)

0 2.5 5 7.5 10

∆P(p

sid)

10

8

6

4

2

0

0 10 20 30

0.6

0.5

0.4

0.3

0.2

0.1

0 ∆P(b

ar)

NK

NJ

Pressure Drop Information

Housing Pressure DropFluid at 14.3 cSt (75 SUS), 0.88 S.G.

Housing pressure drop is directly proportional to specificgravity.

Element Pressure DropFluid at 14.3 cSt (75 SUS), 0.88 S.G.

Correct for other fluids by multiplying new viscosity incSt/14.3 (SUS/75) x new S.G./0.88.

Page 193: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

USA25 Harbor Park DrivePort Washington, NY 11050+1 888 333 7255 (toll free in U.S. only)+1 516 484 3600 phone+1 516 484 6247 fax

United KingdomEuropa House, Havant StreetPortsmouth PO1 3PDHampshire, England+44 (0) 23 9230 3303 phone+44 (0) 23 9230 2507 faxm&[email protected] email

Visit us on the Web at www.pall.com

Pall Corporation has offices and plants throughout the world in locations including:Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India,Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand,Norway, Poland, Puerto Rico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland,Taiwan, Thailand, United Kingdom, United States, and Venezuela. Distributors are located in allmajor industrial areas of the world.

Code Bypass Valve ✖ Type

W Non-bypass,(100 psid indicator settingwhere equipped)

Code Seal◆ Material

H NitrileP ChloropreneZ PTFE

encapsulatedfluorocarbon

Part Numbers/Ordering InformationH ◆ 2035 ▼ ■ ● ✖ v ❚ (e.g., HZ2035B06NKRWE1)

Bulletin #IM2035EN 2/07

© Copyright 2007, Pall Corporation. Pall, , and Rigimesh are trademarks of Pall Corporation. ® Indicates a Palltrademark registered in the USA. is a service mark of Pall Corporation.

Code Type of▼ Port

B06 3⁄8" NPTB08 1⁄2" NPT

Code Filter Media■ Grade Options

NK 5 µmNJ 10 µm++ Housing only

Dimensional Drawings

Rigimesh Element Part NumberHC2035E ■ 4 ◆ Y923 (e.g., HC2035ENK4ZY923)

Code Filter Media■ Grade Options

NK 5 µm(3)

NJ 10 µm(3)

Code Seal◆ MaterialH NitrileP Chloroprene

Z PTFE encapsulatedfluorocarbon

Code Additional❚ Options

Omit None

1 Mountingbracketassembly

.17

∅ 3.97

∅2 .97

1.05 (0.28 with BH plug)

3.85

6.67

.33

1” HEX

2.75

1.102

.984

.984

3.00

1.102

.75

1.735 1.735

4X .375-16 LNC-2BTHREAD .70 DEEP

INLETOUTLET

OUTLET INTL

ET

FRONT VIEW (1)(2)

TOP VIEW (1)(2)

1 Dimensions are in inches.2 3.0" required for element removal.3 98% efficiency.

Code Length● (nominal)

R 4"

Code ∆P Devicev Options

E visual, 6,000 psirated

0 No port

BH Plug

Page 194: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Features• Ultipor® III or Rigimesh® stainless steel media• Flows to 75 lpm (20 gpm) • Pressures:

2050 Series: 690 bar (10,000 psi) 2060 Series: 1034 bar (15,000 psi)2070 Series: 1379 bar (20,000 psi)

• Port sizes: 3/8″, to 3/4″

Notes and SpecificationsMaximum Working Pressure:

2050 series: 690 bar (10,000 psi)2060 series: 1000 bar (14,500 psi)2070 series: 1379 bar (20,000 psi)

Proof Pressure:2050 series: 1034 bar (15,000 psi)2060 series: 1500 bar (21,750 psi)2070 series: 2068 bar (30,000 psi)

Typical Burst Pressure:2050 series: 2758 bar (40,000 psi)2060 series: 3490 bar (50,750 psi)2070 series: 5516 bar (80,000 psi)

Temperature Range: Nitrile seals: -43˚C to 107˚C (-45˚F to 225˚F)Fluorocarbon Seals: -29˚C to 120˚C (–20˚F to 250˚F)60˚C (140˚F) maximum in HWCFor water glycol fluids with Ultipor III media

Filter Element Collapse Pressure: 9020 series: 20 bar (290 psid);

9021 series: 207 bar (3000 psid);310 bar (4500 psid) with Rigimesh all stainless steel media (NK or NJ options)

Materials of Construction: Stainless steel; titanium bowl(2070/71)

Element Construction: Ultipor III: Inorganic fibers impreg-nated and bonded with epoxyresins; stainless steel hardware.Rigimesh: All stainless steel (noresin binders)

Pressure Drop InformationFigure 1. Housing pressure drop using fluid with 0.9 S.G. Housing pressure drop is directly proportional to specific gravity.2050/2060 Series

2070 Series

Element Pressure Drop Multiply actual flow rate times factor to determine pressure dropwith fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids bymultiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9.Note: factors are per 1000 lpm and per 1 gpm.

9020 Series Filter Elements — bar/1000 lpm (psid/gpm)

Length Code KZ KP KN KS KT

4 34.61 (1.90) 14.94 (0.82) 9.84 (0.54) 6.38 (0.35) 3.83 (0.21)8 17.49 (0.96) 7.47 (0.41) 4.92 (0.27) 3.28 (0.18) 2.00 (0.11)

9021 Series Filter Elements — bar/1000 lpm (psid/gpm)

Length Code DP DS/NK DT/NJ

4 49.37 (2.71) 36.54 (0.53) 12.39 (0.68)8 24.59 (1.35) 17.24 (0.25) 6.19 (0.34)

2050/2060/2070 SeriesHigh Pressure Filter Assemblies

2050, 2060, and 2070 series filter housings

Data Sheet PM&E 2050/2060/2070-A

0

10

20

30

40

50

0 2 4 6 8 10 12 14 20

0 10

Flow (gpm)

Δ P

(bar

)

Δ P

(psi

d)

Flow (lpm)

16 18

V06 B06V09V09

, C, W, C, WA, BA, BBB08/121

20 30 40 50 60

0

1.0

2.0

3.0

70

0

10

20

30

40

50

0 2 4 6 8 10 12 14 16

0 10

Flow (gpm)

P (b

ar)

P (p

sid)

Flow (lpm)

V06V09W12V12

20 30 40 50 60

0

1.0

2.0

3.0

2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 1

Page 195: NEW: 2022 Series Filter Assembly - jhbennett.com 2022 Series Filter Assembly ... A SAE J514 straight thread B NPT D* Flange SAE J518c-Code 61 *7502 series only. TABLE 4: PORT SIZE

Dimensional Drawings

Ordering Information

Assembly P/N: H 20 T

Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8

Ultipor Element P/N: HC F Y923

Table 2 Table 4 Table 5 Table 1

Rigimesh Element P/N: HC 9021 E

Table 4 Table 5 Table 1

Table 3: Port Options

Code Port SeriesA08 1/2″ SAE J514 straight thread 2050/51, 2060/61

A12 3/4″ SAE J514 straight thread 2050/51

B06 3/8″ NPT 2050/51, 2060/61

B08 1/2″ NPT 2050/51, 2060/61

B12 3/4″ NPT 2050/51

C08 1/2″ BSP ISO 228 threads 2050/51, 2060/61

C12 3/4″ BSP ISO 228 threads 2050/51

V06 3/8″ medium pressure threaded 2050/51, 2060/61, 2070

V09 9/16″ medium pressure threaded 2050/51, 2060/61, 2070

V12 3/4″ medium pressure threaded 2050/51, 2060/61, 2070

W12 3/4″ weld sockets 2050/51

Table 6: Bypass Valve Options

Code Valve Housing SeriesB 3.4 bar (50 psid ) 2050, 2060, 2070

J 10 bar (150 psid ) 2051, 2061, 2071

S 13.8 bar (200 psid ) 2051, 2061, 2071

W Non-bypass, 100 psid indicator 2051, 2061, 2071*

N Non-bypass, 35 psid indicator 2051, 2061, 2071*

Table 7: Differential Pressure Indicator Options*

Code Indicator ‘H’ Dim.W Explosion proof 79 mm (3.1 in)

E SST visual 28 mm (1.1 in)

0 No indicator port N/A

B SST port plug 3 mm (0.12 in)

Table 8: Mounting Bracket Options

Code Option0 None

1 Mounting bracket kit

*Notes: 1. Select 2 indicator option codes per housing2. Enter indicator codes alphabetically; put “0” code after alpha code if applicable3. 2070/71 series does not have indicator ports; enter “00” in part number

* Note: 2071 series does not have indicator ports

New York – USA+1 516 484 3600 telephone +1 888 333 7255 toll free+1 516 625 3825 fax

Portsmouth – UK+44 (0)23 9230 3303 telephone+44 (0)23 9230 2507 faxm&[email protected]

Visit us on the Web at www.pall.com/m&e

Table 2: Series Options

Housing Code Description Element Code50 690 bar (10,000 psi) housing with 50 psi

bypass valve 9020

60 1000 bar (14,500 psi) housing with 50 psi bypass valve 9020

70 1379 bar (20,000 psi) housing with 50 psibypass valve 9020

51 690 bar (10,000 psi) 9021

61 1034 bar (15,000 psi) 9021

71 1379 bar (20,000 psi) 9021

© Copyright 2005, Pall Corporation. Pall, , Ultipor and Rigimesh are trademarks of Pall Corporation. ® Indicates a Pall trademark registered in the USA. is a service mark of Pall Corporation.

Table 1: Seal Options

Code SealsH Nitrile

Z Fluorocarbon

Table 5: Length Options

Housing Element Length (in)Code CodeR 4 4

S 8 8

Table 4: Filter Element Options

Code Bx(c)≥ Element 1000 Series

KZ 3 9020 (Ultipor III)

KP 5 9020 (Ultipor III)

KN 7 9020 (Ultipor III)

KS 12 9020 (Ultipor III)

KT 22 9020 (Ultipor III)

DP 5 9021 (Ultipor III)

DS 12 9021 (Ultipor III)

DT 15 9021 (Ultipor III)

NK 5 µm* 9021 (Rigimesh)

NJ 10 µm* 9021 (Rigimesh)

* Nominal length

*

2X10.31 mmØ.406 in

57.15 mm2.25 in

22.10 mm.87 in

INLET OUTLET

25.4 mm1.00 in

101 mm4 in

95 mm3.75 in

Element change

1.19 Hex.

249.94 mm/9.84 in (R-length)345.44 mm/13.60 in (S-length)

150 Ref. mm 5.9 Ref. in

‘H’ Dim.Ref.

‘H’ Dim. Ref.

Visualindicator

Explosionproof indicator

69.85 mm2.75 in

30.23 mm1.19 in

OUTLET

92.20 mm3.63 in

24.99 mm.984 inINLET

OUTL

ET

24.99 mm.984 in

27.99 mm1.102 in

4 X 3/8-16 UNC 2B .70 deep

Secondary portlocation (2050/51and 2060/61 only)

Primary portlocation (2050/51and 2060/61 only)

104.8 mm4.125 in

111.4 mmØ4.385 in

Mounting dimensions same as other options.INLET

OUTL

ET

V12 portoption only

* 98% efficiency

2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 2