© Blue Graphics Concept Sauer-Danfoss© Blue Graphics Concept Sauer-Danfoss
Design Closed Circuit
Introduction, May 2012
![Page 2: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/2.jpg)
2
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 3: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/3.jpg)
3
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 4: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/4.jpg)
4
MENU
1. System OverviewHydrostatic Transmission• Continuously variable speed w/o loss of traction
A
BSpeed [km/h]
Tra
cti v
e F
orc e
[N]
Pump Ratio Motor Ratio
Installed Engine Power
hydrostatic transmission
- source 1 -
![Page 5: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/5.jpg)
5
MENU
1. System OverviewHydrostatic Transmission
• Motor output torque and speed depends on pump and motor displacement
• Speed of hydrostatic transmission is reciprocal to displacements
• Torque is proportional to displacements
![Page 6: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/6.jpg)
6
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 7: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/7.jpg)
7
MENU
2. Functionality of ComponentsIntegrated Charge Pump
![Page 8: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/8.jpg)
8
MENU
2. Functionality of Components Integrated Charge Pump • Charge pump is a fixed displacement pump (gerotor-type)
which is directly connected to the pump input shaft
• Charge pump displacement should be sized to approximately 10% of whole system displacement (pump and motor(s) displacements) in most applications
![Page 9: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/9.jpg)
9
MENU
2. Functionality of Components Charge Pump - Functions
Charge Pump flow rate functions:• Replenish leakage oil of pump and motor• Replenish loop flushing oil through the flushing valve• Provide flow for the servo control systems• Provide flow for auxiliary circuit functions e.g. parking brake
release
Charge Pump pressure functions: • Maintain low loop pressure• Provide sufficient pressure to activate the servo control
systems
![Page 10: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/10.jpg)
10
MENU
2. Functionality of ComponentsCharge Pressure Relief Valve
![Page 11: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/11.jpg)
11
MENU
2. Functionality of Components Charge Pressure Relief Valve• Charge pressure relief valve is necessary
to maintain low loop pressure• Protects the charge pump by limiting the
charge pressure• Excess charge pump output flow is
directed into the pump case
![Page 12: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/12.jpg)
12
MENU
2. Functionality of ComponentsCharge Check Valve
![Page 13: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/13.jpg)
13
MENU
2. Functionality of Components Charge Check Valve• It protects the charge pressure system
(charge pump), otherwise a backflow from high pressure side will damaged the charge pump
![Page 14: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/14.jpg)
14
MENU
2. Functionality of ComponentsLoop Flushing System
![Page 15: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/15.jpg)
15
MENU
2. Functionality of ComponentsLoop Flushing System• Loop Flushing is necessary because of cooling
requirements and contamination removal of system circuit
• The LF-system removes fluid from the low pressure side of the closed circuit system
• Loop Flushing valves are available with different flow rates to optimize flush flow requirements in all system operating conditions
![Page 16: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/16.jpg)
16
MENU
2. Functionality of ComponentsHigh Pressure Relief Valve (HPRV)
![Page 17: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/17.jpg)
17
MENU
2. Functionality of ComponentsHigh Pressure Relief Valve (HPRV)• High pressure relief valves are needed in hydrostatic
transmission systems to limit maximum pressures– Pressures above the product ratings will damage the
transmission– HPRV protect pumps, motors, hoses and other system
components
![Page 18: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/18.jpg)
18
MENU
2. Functionality of Components Pressure Limiter• Pressure Limiter is a non dissipative high pressure
control
• Limits the heat generated in the system when pressures are too high
• PL changes the displacement of the pump in response to high system pressure
![Page 19: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/19.jpg)
19
MENU
2. Functionality of Components Bypass• Bypass function allows an internal connection to be
made between the two loops in the hydrostatic transmission
• Function allows the vehicle to be moved without the engine running– Allows for disabled vehicles to be loaded onto a trailer or moved
off the road– Intended to be for slow, short durations otherwise the
hydrostatic transmission can be damaged
![Page 20: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/20.jpg)
20
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 21: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/21.jpg)
21
MENU
3. Hydraulic FluidsWhat do you know about Hydraulic Fluids?
Dirt
Blood
SunWaterAir
Alcohol
![Page 22: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/22.jpg)
22
MENU
3. Hydraulic FluidsOverview Hydraulic Fluid Groups
1. Mineral oil based hydraulic fluids
2. Biogradeable hydraulic fluids• Syntetic ester (HEES) • Rape oil alkaline (HETG)
3. Fire resistance fluids• ATEX Regulation
![Page 23: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/23.jpg)
23
MENU
3. Hydraulic FluidsRecommended Hydraulic Fluids• Find recommended Hydraulic Fluids for Sauer-Danfoss
hydrostatic components in Technical Literature*
• Fluids meeting the technical literature requirements will very likely provide acceptable unit life
• field testing is the only truly indication of fluid performance
• Sauer-Danfoss warranty claim policies do not apply for fluid related damage
*: “Hydraulic Fluids and Lubricants Technical Information”; page 20
![Page 24: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/24.jpg)
24
MENU
3. Hydraulic FluidsPhysical Behavior
1. Viscosity• Viscosity grade (VG)• Depends on temperature and pressure• Compromise between flow losses and leakage
2. Density• Depends on temperature and pressure
![Page 25: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/25.jpg)
25
MENU
3. Hydraulic FluidsPhysical Behavior
Temperature-Behavior Pressure-Behaviour
Temperature Temperature
kine
mat
ic Vi
scos
ity
kine
mat
ic Vi
scos
ity
![Page 26: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/26.jpg)
26
MENU
3. Hydraulic FluidsViskosity and Temerature Limits• Viscosity and temperature limits in the table “Viscosity and
temperature limits” in technical information* are to be observed
• Under normal operating condition it is recommended to keep the temperature in the range of 30 °C to 60 °C
• Rule of thumb: fluid temperature increase from 80 °C [176 °F] to 90 °C [194 °F] may reduce fluid life by 50 %
*: “Hydraulic Fluids and Lubricants Technical Information”; page 19
![Page 27: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/27.jpg)
27
MENU
3. Hydraulic FluidsAdditives
Improvement of oil attributes • Viscosity-temperature behavior• Wear protection• Corrosion protection• Ageing resistance• Foam prevention• Bond to dirt particles
![Page 28: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/28.jpg)
28
MENU
3. Hydraulic FluidsSelection Criteria• Manufacturer‘s instructions
• Release of diverse oils
• Depends on system• Application (vehicle, temperature conditions) • Fill rate
• Application environment• Climate• Area of application (i.e. environmental, flammability regulations, etc.)
![Page 29: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/29.jpg)
29
MENU
3. Hydraulic FluidsAdditional Information• Technical Information “Hydraulic Fluids and Lubricants”
(520L0463)• Technical Information “Experience with Biodegradable
Hydraulic Fluids” (520L0465)
![Page 30: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/30.jpg)
30
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 31: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/31.jpg)
31
MENU
4. FiltrationContamination
Sources of contamination:– Installation– System components– Fill oil– Repair of a unit
Types of contamination:– Metal– Synthetic materials– Organic materials– Plastic– Water– Etc.
Scratches on Piston Shoe
![Page 32: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/32.jpg)
32
MENU
4. Filtration Cleanliness ClassesISO 4406 1999:• Specification of three cleanliness
classes correlated to particle size ≥4; ≥6; ≥14 [μm]
• Example:ISO 18/16/13
number of particles 1/ml
cleanliness classes (ISO 4406)
0,01-0,02 10,02-0,04 20,04-0,08 30,08-0,16 40,16-0,32 50,32-0,64 6
etc. etc.40-80 1380-160 14160-320 15320-640 16
640-1300 171300-2500 182500-5000 19
5000-10000 2010000-20000 2120000-40000 2240000-80000 2380000-160000 24
![Page 33: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/33.jpg)
33
MENU
4. Filtration Cleanliness ClassesSauer-Danfoss recommends the cleanliness classes below for different applications*
Product Required cleenliness class ISO 4406-1999
Steering components with open center 22/20/17Orbital motors 22/20/16Steering components with LS and closed center
21/19/16Proportional spool valvesAxial + radial piston pumps and motors
22/18/13Gear pumps and motorsCartridge and electrohydraulic valves 18/16/13
Maximum class at machine start up 25/22/17
*: “Design Guideline for Hydraulic Fluid Cleanliness Technical Information” (520L0467), p. 13, Spreadsheet: “Fluid cleanliness requirements according to product“
![Page 34: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/34.jpg)
34
MENU
4. Filtration Kind of FiltrationPartial flow filtration
+ Small filter- Partial backflow of oil w/o filtration - Charge pump unprotected (pre-filtration
necessary)
![Page 35: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/35.jpg)
35
MENU
4. Filtration Kind of FiltrationFull flow filtration
+ Complete oil filtration + Small filter- Charge pump unprotected ( pre-filtration necessary)
![Page 36: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/36.jpg)
36
MENU
4. Filtration Kind of FiltrationSuction filtration
+ Charge pump protected- Large filter surface necessary- Disadvantageous at low temperature
![Page 37: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/37.jpg)
37
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 38: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/38.jpg)
38
MENU
5. ReservoirOverviewArt der FilterungTasks:• Fluid reservoir
• Ensures there is enough oil for hydraulic system
• Cooling
• Separates dirt, water and air
• Assures smooth fluid flow (laminar flow) at suction
![Page 39: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/39.jpg)
39
MENU
Main Menu
Basic Hydrostatic (closed circuit)
System Overview
Functionality of
components
Hydraulic Fluids
Filtration Reservoir Heat Exchanger
![Page 40: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/40.jpg)
40
MENU
6. Heat ExchangerFunction and TypeRemoval of hydraulic-system heat
• Prevents overheating of oil• Ideal oil-temperature should be 60 to 80°C
Construction type in mobile hydraulic• Oil-air-heat exchanger
Oil-air heat exchanger
![Page 41: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/41.jpg)
41
MENU
6. Heat ExchangerDesign Criteria
vehicle engine cooler fan SD FD system
![Page 42: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/42.jpg)
42
MENU
6. Heat ExchangerSauer-Danfoss Fan Driveexample: closed circuit
![Page 43: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/43.jpg)
43
MENU
The EndMENU
![Page 44: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/44.jpg)
44
MENU
Many Thanks for YOUR Attention!
When Chuck Norris says “420 bar" he is not quoting the pressure rating of the H1B motor, he is telling you how much pressure his foot will apply to your face.
The three things that make hydraulics work:1. Flow2. Pressure3. Chuck Norris
![Page 45: Design Closed Circuit](https://reader036.vdocuments.mx/reader036/viewer/2022081503/56816330550346895dd3b082/html5/thumbnails/45.jpg)
45
MENU
Overview Literature SourcesMENU
- Source 1 - Ölhydraulik – Handbuch für die hydrostatisch Leistungsübertragung in der
Fluidtechnik; Findeisen, D.; Springer