Download - BEAUMONT, AB
FOR SALE
PRIMEDEVELOPMENTSITEZONED FOR 23 TOWN HOMES
16 EXISTING UNITS
5109 55 STREETBEAUMONT, AB
Cushman & Wakefield EdmontonSuite 2700, TD Tower10088 102 AvenueEdmonton, AB T5J 2Z1 cwedm.comCushman & Wakefield Edmonton is independently owned and operated / A Member of the Cushman & Wakefield Alliance. No warranty or representation express or implied is mad to the accuracy or completeness of the information contained herein, and same is submitted subject to errors, omissions, change of price, rental or other conditions, withdrawal without notice, and to any special listing conditions imposed by the property owner(s). As applicable, we make no representation as to the condition of the property for properties in question. March 23, 2020
Doug RaePartner 780 429 9397 [email protected]
BEAUMONT, AB$2,300,000
PROPERTYHIGHLIGHTS
• In fill site shovel ready
• Services, road work in place
• Surrounded by established neighborhood
Z
Site
PROPERTY DETAILSLegal Description Lot1, Block1, Plan 782 1384
Municipal Address 5109 55 Street, Beaumont, AB
Zoning RMD2 - Residential medium density 2 district
Proposed Use Multi - Attached dwelling
Site Area 2.437 acres
Density (max) 80 dwelling units per gross hectare 23 proposed new units (16 existing units)
Min, Main Floor Area Required 56.67m2 (610 SF)for 2 story or more
Proposed Main Floor Area 57.11m2
Building Height (Max) up to 12.0m allowed
• $2,300,00
• Legal
• Muni
SITE PLANS
WH
WH
WH
WH 13' - 1 1/2"
4000
INDICATESEXISTINGTREE ON
SITE
INDICATESEXISTINGTREE ON
SITE
PROPOSEDNEW BUILDING E
8 UNITS
PROPOSEDNEW BUILDING B
6 UNITS
PROPOSEDNEW BUILDING D
9 UNITS
NEWAMENITY SPACE
NEWTRANSFORMER
NEW GARBAGEENCLOSURE
13' -
1 1/2"
52 AVE.
55 S
TREE
T
EXISTING MANHOLE
EXISTING FIREHYDRANT
EXISTING FIREHYDRANT
EXISTING FIREHYDRANT
EXISTING MAN HOLE
EXISTINGMAN HOLE
EXISTING MAN HOLE
EXISTING STREETLIGHT
EXISTING STREETLIGHT
EXISTING STREET LIGHT
EXISTINGTRANSFORMER
EXISTING STREETLIGHT
EXISTING MANHOLE
EXISTING MANHOLE
EXISTINGSITE ACCESS
EXISTINGSITE ACCESS
EXISTINGELEC. BOX
EXISTINGTELEPHONE
BOXES
EXISTINGTRANSFORMER
EXISTINGTELEPHONE
BOXES
EXISTINGTRANSFORMER
EXISTINGELEC. BOX
PRO
PER
TY L
INE
PROPERTY LINE
PROPERTY LINE
R=111.51A= 26.18 89°44'1
0.50
SETB
ACK
LINE
0.38
359
°
SETBACK LINE
SETBACK LINE
EXISTING ROAD
EXISTING BUILDING C5 UNITS
EXISTINGVISITORPARKING
EXISTINGVISITORPARKING
EXISTINGVISITORPARKING
EXISTING VISITORPARKING
EXISTING BUILDING A11 UNITS
EXIS
TIN
G R
OAD
EXISTING STREETLIGHT
EXISTINGTELEPHONE BOX
SHADED AREA REPRESENT SITE ANDBUILDINGS NOT IN THIS CONTRACT!
MIN2% SLOPE
NEW CONC.PAD(TYP.)
2 CAR GARAGEIN THE UNIT (TYP.)
PROPOSED MAIN FL. ELEV.731.75m
PROPOSED MAIN FL. ELEV.731.75m
PROPOSED MAIN FL. ELEV.731.20m
50' - 0"
15200
20' - 1"
6100
22' - 11 1/2"
7000
19' - 6"
5900
50' - 0"
15200
4' - 4 1/2"
1300
13' - 1 1/2"
4000
179'
- 7"
5470
0
33' -
3"
1010
0
28' -
3 1
/2"
8600
158'
- 9"
4840
0
24' -
10"
7600
119'
- 5"
3640
0
36' -
2"
1100
0
2H FIRE WALL
731.85
731.50
730.90
730.57
730.64
730.75
730.90
730.59
730.67
730.47
728.79
730.42
728.20
729.64
730.49
730.44
730.45
730.38
730.33
727.61
721.15
729.39730.37
730.62
730.45
PROPOSED GARAGE FL. ELEV.730.65m
PROPOSED GARAGE FL. ELEV.731.05m
731.15
731.06730.74
730.89
731.75
730.80
PROPOSED GARAGE FL. ELEV.731.00m
739.49
4' - 6"
NEW WOOD FENCESEE DETAIL 8/A02
NEW FENCE
66' - 7"
20300
367'
- 6"
1120
00
9 1/2"
200
A023
8' - 4
"10
' - 8"
5' - 1
0"A021
Sim
7' - 8"
2300
41' - 1"
12500
FOR THE LANDSCAPESEE LANDSCAPE DRAWINGS
FOR THE LANDSCAPESEE LANDSCAPE DRAWINGS
LEGAL DESCRIPTION: LOT1, BLOCK1, PLAN 782 1384
MUNICIPAL ADDRESS: 5109 - 55TH STREET, BEAUMONT, AB
ZONING: RMD2 - RESIDENTILA MEDIUM DENSITY 2 DISTRICT
PROPOSED USE: MULTI - ATTACHED DWELLING
SITE AREA: 9861.10m2 (2.437 acre)= 0.986 ha
DENSITY (max.) 80 DWELLING UNITS PER GROSS HECTARE23 PROPOSED NEW UNITS (16 EXISITNG UNITS)
MIN. MAIN FLOOR AREA REQUIRED = 56.67m2 (610 S.F.) FOR 2 STORY OR MOREPROPOSED MAIN FLOOR AREA = 57.11m2
BUILDING HEIGHT (MAX) UP TO 12.0m ALLOWED
SITE STATISTIC:
AERIAL VIEW
NOTE FOR LANDSCAPE DESIGNER:CHECK THE SITE FOR EXITING TREES1
LEGEND:
NEW PROPOSED BUILDING
AREA NOT IN CONTRACT
CONCRETE PAVING
WOOD FENCE
Scale
Project number Date
Drawn by Checked by
CONSULTANT
PERMIT STAMP
SEAL
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THEPROPERTY OF KUMAR ARCHITECTURE LTD, THE COPYRIGHT INTHE SAME BEING RESERVED TO THEM. NO REPRODUCTION ISALLOWED WITHOUT THE PERMISSION OF KUMARARCHITECTURE AND WHEN IT IS MADE MUST BEAR ITS NAME.THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR ISTO VERIFY THE DIMENSIONS AND DATA NOTED HEREIN WITHTHE CONDITIONS ON SITE AND IS RESPONSIBLE FORREPORTING ANY DISCREPANCY TO KUMAR ARCHITECTURE LTDFOR ADJUSTMENT.
PROJECT
DRAWING TITLE
REVISION
As indicated
1/4/
2019
9:4
4:57
AM
1A01
SITE PLAN
AB1618
STONEHOUSE CONDOS
November 5th 2018
ES DAN
1 : 250A01
1 SITE PLAN
Rev. yy-mm-dd Revision /Drawing Issue Drawn by1 2019-01-04 ISSUED FOR DEVELOPMENT PERMIT ES