download product information
TRANSCRIPT
Brachytherapy applicators and accessories
3
TreatmentDelivery
TreatmentPlanning
Imaging
At Nucletron, we believe that our solutions, services and extensive knowledge of precisely targeted
radiotherapy can play a vital role in the successful treatment of cancer. Our key technological advances
have resulted in an integrated package of treatment planning and delivery systems. This Nucletron
Applicator Guide provides a comprehensive overview of our applicator portfolio for brachytherapy.
Nucletron Brachytherapy Solutions With 35 years of experience, Nucletron is currently the preferred partner for about 60% of brachytherapy
institutions worldwide! Continuous research and development in close collaboration with our customers allow
us to find comprehensive and smart solutions to clinical needs, and to remain at the forefront of brachytherapy.
We continue to build on this with our global presence and an ongoing investment in brachytherapy innovation.
Nucletron Applicators Applicators are a pivotal part of Nucletron’s fully integrated solutions. With a broad portfolio of specialized
applicators, Nucletron offers a complete and customer-focused applicator range for more than 15 types of
cancer in a variety of anatomies.
Flexitron® and microSelectron® Remote Afterloading platforms Nucletron has established an unparalleled reputation for reliability, safety and performance in treatment
delivery. The groundbreaking software architecture of our remote afterloading platforms combines these
qualities with all-in-one versatility and unmatched flexibility.
Flexitron® is the newest afterloading platform in the market, offering unrivalled innovation potential.
Due to its extra source drive, it offers future possibilities for advanced brachytherapy techniques. The design
of Flexitron® was strongly driven by customer input, paying close attention to safety and quality of patient
treatment. MicroSelectron® Digital provides a platform for HDR brachytherapy that synergizes all the benefits
of a safe and reliable treatment solution, proving its worth on a daily basis in hundreds of brachytherapy
institutes around the world.
Oncentra® Brachy The Oncentra Brachy treatment planning platform enhances workflows by reducing planning time by up
to 50%, while delivering the highest levels of accuracy and confidence in treatment. Nucletron’s advanced
brachytherapy software also addresses the call for reproducibility. It leverages Applicator Modeling, allowing
automatic reconstruction of the exact applicator geometry and source path, and library plans to ensure
efficiency and consistency.
Introduction
4 5
Nucletron’s Brachytherapy Solutions 3
How to use this Applicator Guide 4
Applicator sections
Index 114
Tables for Flexitron markers and Transfer Tubes 118
Tables for microSelectron markers and Transfer Tubes 120
ContentHow to use this Applicator Guide
In this Applicator Guide, applicators are presented by body site. All body sites are easily identified by color coding.
Where a particular applicator can also be used for other body sites, a cross reference is given on the index-page at the
start of the relevant applicator section.
The applicators and accessories in this guide are designed for use with the Nucletron Flexitron® and microSelectron®
afterloaders only. Applicators and accessories that are specific to one or other afterloader are so indicated.
Corresponding transfer tubes, x-ray catheters and CT-markers per applicator (type) and afterloader can be found on
page 118 and 120.
Sterilization adviceSterilization advice provided in this document is indicative and applies to newly purchased applicators. For more
information regarding sterilization of a particular applicator, please consult the User Manual or Sterilization Advice
Chart. The latest version of this document is leading and can be downloaded from www.nucletron.com/applicators*
Safety in the Magnetic Resonance EnvironmentThe symbols shown below are used to indicate safety safety of medical devices in the Magnetic Resonance
environment.
MR Safe - an item that poses no known hazards in all MR environments.
MR Conditional - an item that has been demonstrated to pose no known hazards in a specified
MR environment with specified conditions of use (specified in the user manual).
* Register for a ‘My Nucletron’ account. The documentation can be found in the Resource Library.• Forinformationaboutapplicatorsthatarenotmentionedinthisbrochure,pleasecontactyourlocalsalesoffice.• Availabilityofproductspresentedinthisguideissubjecttolocalregulatoryapproval.
Gynecology - 6
Bronchus & Esophagus - 50
Breast - 60
Prostate, Rectum & Bladder - 68
Skin & Surface - 78
Head & Neck - 86
Pancreas & Bile Duct - 94
Needles & Flexible Implant Tubes - 98
Quality Assurance & Accessories - 108Visitwww.nucletron.com/applicatorsforthemostup-to-dateApplicatoroverview.
6 7
Cervix: Utrecht Interstitial CT/MR Applicator Set 8
Fletcher CT/MR Applicator Set 10
Cervix Rotterdam Applicator Set 12
Fletcher Williamson Applicator Sets 14
Standard CT/MR Applicator Set 16
Henschke Titanium Applicator Set 18
Interstitial Ring CT/MR Applicator Set 20
Vienna Ring CT/MR Applicator Set 22
Ring CT/MR Applicator Set 24
Ring Applicator Set 26
Adjustable Cervix Applicator Set 42
Vagina: Vaginal Mold Applicator Set 28
Vaginal CT/MR Multi Channel Applicator Set 30
Vaginal CT/MR Applicator Set 32
Ti Vaginal Cylinder Applicator Set 34
Shielded Cylindrical Applicator Set 36
Miami Vaginal Applicator Set 38
Vaginal Applicator Set 40
Endometrium: Norman Simon Applicator Set 44
Rotte Endometrial Applicator Set 46
Accessories Intrauterine Tube (4 mm) 47
MR Line Marker Set 48
Smit Sleeve 49
Alternatives for vaginal brachytherapy Section Prostate Stepper Template Set Prostate, Rectum & Bladder 72
MUPIT Applicator Set Prostate, Rectum & Bladder 74
Intracavitary Mold Applicator Set Prostate, Rectum & Bladder 76
Perineum Section MUPIT Applicator Set Prostate, Rectum & Bladder 74
GuidetoGynecologyapplicatordimensions
Ringapplicators:
Ring Tube
Intrauterine Tube
* Thedimensionsareapplicabletoallapplicators,withtheexceptionoftheCervixRotterdamApplicator. Refertorelevantpageforovoiddimensionsofthisapplicator.
Tandem&Ovoidapplicators:
Ovoid Tube
Intrauterine Tube
Ovoid Tube
Intrauterine Tube
Ovoid dimension*
xxmm
Ring dimension
xxmm
Ovoid angle
Intrauterine angle
Ring angle
Gynecology
8 9
• Canalsobeusedasastandardintracavitaryapplicator.• Asymmetricalovoidplacementispossible.• Useofneedleswithroundedtipcanreducetheriskofperforationofcriticalstructures, andisrecommendedforusewithinterstitialcervixapplicators.• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanual777.00077.
Order Information
Utrecht Interstitial CT/MR Applicator Set (6 mm)
part # 110.270A01Part Number Description
189.735 Ovoid Tube 1
189.740 Ovoid Tube 2
189.739 IntrauterineTube15º
189.745 IntrauterineTube30º
110.240 InterstitialovoidPair15mm,15º
110.241 InterstitialovoidPair20mm,15º
110.242 InterstitialovoidPair25mm,15º
110.243 InterstitialovoidPair30mm,15º
189.714 Insertion Tool
110.268 ObturatorsSet(Setof5)
189.751 RectalRetractor40
189.742 RectalRetractor30
189.741 FixationNutforRectalRetractor
189.722 Fixationmechanism
189.750 Fixationclip
189.930 FixationnutsSet(spare)(Setof5)
101.012 SterilizationCaps(packof50)
110.267 CervicalStopper
110.283 ScrewdriverforOvoidsandStopper
008.033 PlasticScrewM5PPSU(10pcs)
189.040 CleaningbrushSet
189.043 CleaningbrushSet
Utrecht Interstitial CT/MR Applicator Set (4 mm)
Part # 110.270A02
ThesameUtrechtInterstitialApplicatorSet,butfeaturingø4mmIntrauterineTubes
AccessoriesPart Number Description
110.230*ProGuideRoundNeedleSet,6Fx294mm(Setof5,singlepacked,deliveredsterile)
110.232*Guiding Tube for Ovoids (Setof5,singlepacked,deliveredsterile)
189.769 IntrauterineTube,diameter6mm,45º
110.296/298/300 IntrauterineTube,d=4mm,15°/30°/45°
110.272InterstitialOvoidSet25º(15mm,20mm,25mm,30mm)
101.031 FixationMechanismforOvoidTubes
189.566**SmitSleevesCT/MR(boxof10,l=40mm,d=9mm)
110.700 5pinsforAdjustableMechanism
189.894 SparepartsetPlasticScrewM5PPSU(10pcs)
189.724 Fixationpart1* Required for interstitial treatment. **Formoreoptions,refertolastpageoftheGynecologysection.
Utrecht Interstitial CT/MR Applicator Set
• Makingcomplextreatmentsfastandeasy• Targeteddoseoptimization• SeamlessintegrationwithOncentraBrachytreatmentplanning
Applicable body sites:
• Cervix• Endometrium
xxmm
Indication of ovoid dimensions of UtrechtInterstitialCT/MRApplicator
MR safe
Image shows the applicator with the Intrauterine Tube with 4 mm diameter.
“Combinedintracavitary/interstitialbrachytherapyforcervicalcancernotonlyprovidesthe possibilitytoincreasethetargetvolumedosebutalsotoreducethedosetoorgansatrisk”
InaJürgenliemk-Schulz UniversityMedicalCenter,Utrecht,theNetherlands
TheUtrechtInterstitialCT/MRApplicatorSethasbeenspecificallydevelopedforcombinedintracavitary/interstitialtreatmentofgynecologiccancers,withacombinationofintracavitaryandinterstitialbrachytherapy.ItsdesignisbasedontheFletcherCT/MRApplicatorSet,andusestheovoidsasatemplateforinterstitialneedleplacement.High-qualityProGuideneedlesareeasilyinsertedthroughguidingtubeswhentheapplicatorisinplace.Theinsertiondepthoftheneedlescanbecontrolledusingtheinsertiontool.Theyareindividuallylockedinplacefortreatment.Throughthecombinationofintracavitaryandinterstitialfunctionality,optimallyconformalcervicalandparametrialdosecoveragecan be achieved.
10 11
• TheseparateUtrechtInterstitialApplicatorComplementarySet(110.271)containsallcomponentstoadd interstitialfunctionalitytoaFletcherCT/MRapplicatorandtherebyupgradeittothestate-of-the-artUtrecht InterstitialCT/MRapplicator.• Asymmetricalovoidplacementispossible.• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanual090.713.
Fletcher CT/MR Applicator Set
• Optimizedfitwithpatientanatomy• CompatiblewithCTandMRimaging
Applicable body sites:
• Cervix• Endometrium
Order Information
Fletcher CT/MR Applicator Set, part # 189.730Part Number Description
189.735 Ovoid Tube 1
189.740 Ovoid Tube 2
189.739 IntrauterineTube15°
189.745 IntrauterineTube30°
189.783 OvoidPair15mm(half-ovoids)
189.754 OvoidPair20mm
189.755 OvoidPair25mm
189.756 OvoidPair30mm
189.757 OvoidPair35mm
189.758 OvoidPair40mm
189.742 RectalRetractor30mm
189.751 RectalRetractor40mm
189.741 FixationNutforrectalretractor
110.267 CervicalStopper
189.722 AdjustableFixingMechanism
189.750 FixationClip
198.930 Setof5fixationnuts(spare)
008.033 PlasticScrewM5PPSU(10pcs)
110.283 Screwdriverforovoidsandstopper
101.012 SterilizationCaps(packof50)
AccessoriesPart Number Description
110.296/.298/.300 IntrauterineTube,d=4mm,15°/30°/45°
189.566 SmitSleevesCT/MR(boxof10)
189.769 IntrauterineTube45°
101.031 OvoidTubeFixingMechanism
101.015 SterilizationBox
189.900 OvoidSetwithradius12.5mm(25,30,35,40mm)
189.901 OvoidSetwithradius15mm(30,35,40mm)
110.7005PinsforAdjustableMechanismofFletcherCT/MRApplicator
110.271UtrechtInterstitialApplicatorComplimentarySet,toexpandtheuseoftheFletcherCT/MRapplicatortointerstitialtreatments.
189.894 SparepartsetPlasticScrewM5PPSU(10pcs)
MR safe
xxmm
Indication of ovoid dimensions ofFletcherCT/MRApplicator
TheFletcherCT/MRApplicatorisanunshieldeddesign,usingFletcher-typedosepatterns,forthetreatmentofcervicalcancer.ItcanbeusedincombinationwithCTorMRimagingfortreatmentplanningpurposes.TheadjustablegeometryoftheFletcherCT/MRApplicatorensuresanoptimalfitwiththepatient’sanatomy.TheIntrauterineTubefeaturesacentimeterscaletocontroltheinsertiondepth.Theadjustablestoppercanbesetbetween10and80mm.
12 13
Cervix Rotterdam Applicator Set
• Fasttreatmentplanningthroughfixedgeometry• Strongandlightweightapplicator• Modulardesign
Applicable body sites:
• Cervix• Endometrium• Vagina
Order Information
Cervix Rotterdam Appl. Set IU-15° titanium, part # 137.218Part Number Description
137.235 RightovoidTubeI,IU-15°(ti)
137.236 LeftovoidTubeIII,IU-15°(ti)
137.191 OvoidPair,Ø20mm,small
137.192 OvoidPair,25mm,medium
137.193 OvoidPair,30mm,large
137.230 IntrauterineTubeIIIII,IU-15°,L=30mm,(ti)
137.232 IntrauterineTubeIIIII,IU-15°,L=50mm,(ti)
137.234 IntrauterineTubeIIIII,IU-15°,L=70mm,(ti)
137.246 OvoidTubecouplingfor15°,forovoidsonly(ti)
137.570 Closingcaps(25/pack)
137.574 Screwdriver for ovoid screws
Accessories for 15° SetPart Number Description
137.245 Vaginalcylinderlockingpin(ti)
137.237 Vaginalcylinder&cap15°,Ø30mm,L=60mm
137.207 Vaginalcylinder&cap15°,Ø37mm,L=60mm
137.238 Vaginalcylinder&cap15°,Ø40mm,L=60mm
Cervix Rotterdam Appl. Set IU-30° titanium, part # 137.206 Part Number Description
137.248 RightovoidTubeI,IU-30°(ti)
137.249 LeftovoidTubeIII,IU-30°(ti)
137.191 OvoidPair,Ø20mm,small
137.192 OvoidPair,25mm,medium
137.193 OvoidPair,30mm,large
137.251 IntrauterineTubeIIIII,IU-30°,L=30mm,(ti)
137.253 IntrauterineTubeIIIII,IU-30°,L=50mm,(ti)
137.255 IntrauterineTubeIIIII,IU-30°,L=70mm,(ti)
137.256 OvoidTubecouplingfor30°,forovoidsonly(ti)
137.570 Closingcaps(25/pack)
137.574 Screwdriver for ovoid screws
Accessories for 30° SetPart Number Description
137.245 Vaginalcylinderlockingpin(ti)
137.299 Vaginalcylinder&cap30°,Ø30mm,L=60mm
137.257 Vaginalcylinder&cap30°,Ø37mm,L=60mm
137.239 Vaginalcylinder&cap30°,Ø40mm,L=60mm
Cervix Rotterdam Appl. Set IU-45° titanium, part # 137.217 Part Number Description
137.219 RightovoidTubeI,IU-45°(ti)
137.220 LeftovoidTubeIII,IU-45°(ti)
137.191 OvoidPair,Ø20mm,small
137.192 OvoidPair,25mm,medium
137.193 OvoidPair,30mm,large
137.222 IntrauterineTubeIIIII,IU-45°,L=30mm,(ti)
137.224 IntrauterineTubeIIIII,IU-45°,L=50mm,(ti)
137.226 IntrauterineTubeIIIII,IU-45°,L=70mm,(ti)
137.247 OvoidTubecouplingfor45°,forovoidsonly(ti)
137.570 Closingcaps(25/pack)
137.574 Screwdriver for ovoid screws
Accessories for 45° SetPart Number Description
137.245 Vaginalcylinderlockingpin(ti)
137.240 Vaginalcylinder&cap45°,Ø30mm,L=60mm
137.228 Vaginalcylinder&cap45°,Ø37mm,L=60mm
137.241 Vaginalcylinder&cap45°,Ø40mm,L=60mm
Accessories for all Cervix Rotterdam ApplicatorsPart Number Description
137.244 Rectalspacerlockingpin(ti)
137.243 Rectalspacer,30mmwide,5mmspacingunderovoid
137.242 Rectalspacer,30mmwide,behindovoid
137.190 MiniovoidPair,15mm
137.577 Spareovoidscrews(Setof5pcs)
189.676and following *
SmitSleevesCT/MRforTiIntrauterineTube,L=20mmandlonger,D=6mm(boxof10pcs)
*Formoreoptions,refertothelastpageofgynecologysection.
• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanual777.00114.
* Optional vaginal cylinder parts can be added to extend dosimetry reach.
xxmm
Indication of ovoid dimensions ofCervixRotterdamapplicator
ThetitaniumCervixRotterdamApplicatorhasbeendesignedtosupportfastandsafetreatmentdelivery.Theeasyandstableinsertionsystem,combinedwithitsfixedgeometry,ensurespreciseandreproduciblepositioningofthelightweightapplicator,andseamlessintegrationwithOncentraBrachy.Itcanbeeasilyre-insertedintothecervixusingtheSmitSleeve.Withtheoptionalvaginalcylinderyoucaneasilyextentthetreatmenttoincludethevaginalwallinthesame treatment fraction.
14 15
Fletcher Williamson Applicator Set
• Embeddedshieldingreducesdosetocriticalorgans
Applicable body sites:
• Cervix• Endometrium
Order Information
• TheapplicatorscanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.604.
ThisapplicatorisbasedonthedosimetryoftheconventionalShieldedFletcherStyleApplicator.AlightweighttungstenalloyshieldingisincorporatedintheovoidTubestoreducethedosetothebladderandrectum.Ovoidsarepositionedata60°angletothevaginalaxis.Thesetincludesminiovoidsfornarrowvaginasandthin3.2mmIntrauterineTubes.AspecificFletcherWilliamson`AsiaPacific’ApplicatorSetisavailablewhichisunshieldedandhassmallgeometryovoids.
“TheFletcherWilliamsonapplicatorisawellcrafted,precisioninstrumentwithbladderandrectalshielding. Thisinstrumentallowsustocontinueaqualitytechnicalapproachtogynecologicalbrachytherapywithhigh doseratebrachytherapy.”
J.Stitt,M.D. UniversityofWisconsin,Madison,WIUSA
Fletcher Williamson Asia Pacific Set, part # 085.260Part Number Description
085.233 Ovoid Tube 1
085.234 Ovoid Tube 2
084.203 OvoidPair,Mini
084.041 OvoidPair,half,unshielded
084.042 OvoidPair,20mm,Small,Unshielded
084.028 FixingMechanism,OvoidTube
084.024 IntrauterineTube15°
084.025 IntrauterineTube30°
084.026 IntrauterineTube45°
084.030 CervicalStopper,Small
084.027 AdjustableFixingMechanism
084.158 SterilizingCaps,3.2mm
006.182 Screwdriver
085.258 SterilizationBox
Fletcher Williamson Appl. Set, part # 085.230Part Number Description
085.233 Ovoid Tube 1
085.234 Ovoid Tube 2
085.231 Shielded Ovoid Tube 1
085.232 Shielded Ovoid Tube 2
084.203 OvoidPair,Mini
085.235 OvoidCapPair,20mm,Small
085.236 OvoidCapPair,25mm,Medium
085.237 OvoidCapPair,30mm,Large
084.028 FixingMechanism,OvoidTube
084.024 IntrauterineTube15°
084.025 IntrauterineTube30°
084.026 IntrauterineTube45°
084.030 CervicalStopper,Small
084.027 AdjustableFixingMechanism
084.158 SterilizingCaps,3.2mm(50pcs)
006.182 Screwdriver
085.238 SterilizationBox
16 17
Standard CT/MR Applicator Set
• NodistortionsonCTorMRimages• Applicatorwithfixedgeometrythatensuresreproduciblegeometry• Reproducesstandardlowdoserateisodosedistributions
Applicable body sites:
• Cervix• Endometrium
Order Information
• ApplicatorcanbesterilizedusingsteamsterilizationorEtO.• Usermanual090.613.
MR safe
TheStandardCT/MRApplicatorSetisdesignedusingacompositefibertubingtoeliminatedistortiononCTorMRimages.Thisenablesconformaltreatmentplanningwiththeuseoftransverseslices.Toensureapplicatorandtreatmentintegrity,theStandardCT/MRApplicatorhasafixedgeometry.
Standard CT/MR Applicator Set, part # 101.020Quantity Part Number Description
1 101.021 Ovoid Tube 1
1 101.022 Ovoid Tube 2
1 101.023 IntrauterineTube40mm
1 101.024 IntrauterineTube50mm
1 101.025 IntrauterineTube60mm
1 101.026 OvoidPair20mm
1 101.027 OvoidPair25mm
1 101.028 OvoidPair30mm
1 101.029 RectalRetractor30mm
1 101.030 RectalRetractor40mm
1 101.031 OvoidTubeFixingMechanism
1 008.034 ScrewdriverforOvoidandStopper
1 101.012 SterilizingCaps,CT/MR
16 008.033 Ovoid Screws
1 090.613 UserManual
10 008.033 Ovoid Screws
AccessoriesPart Number Description
101.015 CT-MRSterilizationBox
110.302 IntrauterineTube(4mm),l=50mm,40º
189.566 SmitSleevesCT/MR(l=40mm,d=9mm)(boxof10)
18 19
Henschke Titanium Applicator Set
• Lightweightshieldingtoreducedosetocriticalorgans• Adjustableovoidseparationandshielding
Applicable body sites:
• Cervix• Endometrium
• CEmarked,notavailableforsalesintheUS.• TheapplicatorcanbesterilizedusingsteamsterilizationorEtO.• Plasticcapstoincreasethediameteroftheovoids.• Thecolpostatcapsareavailableindifferentdiameterstoreducethemucosaldose.• Theovoidassemblyisadjustableandassistsineasyinsertion.• Usermanual777.00144.
TheHenschkeTitaniumApplicatorSetisbasedontheoriginallowdosedesignbyDr.Henschke,withadditionalinputfromMemorialSloaneKetteringHospital,NewYork.TheHenschkeTitaniumApplicatorSetreproducesstandardlowdoserateGYNisodosedistributions.
Order Information
Henschke Titanium Applicator Set, part # 110.018Part Number Description
110.019 DualColpostattube
110.435 Intrauterine Tube straight
110.436 IntrauterineTube,15°
110.437 IntrauterineTube,30°
110.438 IntrauterineTube,45°
065.085 ColpostatCapØ25(pair)
065.086 ColpostatCapØ30(pair)
110.283 Screwdriverforovoidsandstopper
110.430 Cervicalstopper
008.033 PlasticScrewM5PPSU(10pcs)
20 21
Set d=34 mm, 60º (max. 9 needles), part # 110.332 A01 Part Number Description
110.352 InterstitialRingTube,diameter34mm,60º
101.051 IntrauterineTube,length20mm,60º(6mm)
101.052 IntrauterineTube,length40mm,60º(6mm)
101.053 IntrauterineTube,length60mm,60º(6mm)
101.057 RectalRetractor,60º
189.930 FixationNutsSet(spare),Setof5
101.012 SterilizationCapsCT/MR,packof50
110.268 Obturators,Setof5
189.714 Insertion Tool
189.040 CleaningbrushSet
189.043 CleaningbrushSet
• Makingcomplextreatmentsfastandeasy• Targeteddoseoptimization• DesignedtoworkwithOncentratreatmentplanningsolutions
Applicable body sites:
• Cervix• Endometrium
Interstitial Ring CT/MR Applicator Set
Order Information
Interstitial Ring CT/MR Applicator Sets (6 mm)
Set d=26 mm, 60º (max. 7 needles), part # 110.330 A01 Part Number Description
110.350 InterstitialRingTube,diameter26mm,60º
101.051 IntrauterineTube,length20mm,60º(6mm)
101.052 IntrauterineTube,length40mm,60º(6mm)
101.053 IntrauterineTube,length60mm,60º(6mm)
101.057 RectalRetractor,60º
189.930 FixationNutsSet(spare),Setof5
101.012 SterilizationCapsCT/MR,packof50,50pieces
110.268 Obturators,Setof5
189.714 Insertion Tool
189.040 CleaningbrushSet
189.043 CleaningbrushSet
• Canalsobeusedasregularintracavitaryringapplicator.• Useofneedleswithroundedtipcanreducetheriskofperforationofcriticalstructures,andis recommendedforusewithinterstitialcervixapplicators.• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanual777.00083.
Accessories for all sets Part Number Description
110.230*ProGuideRoundNeedleSet,6Fx294mm(Setof5,singlepacked,deliveredsterile)
110.273*Guiding Tube for Ring Set for Interstitial Ring (Setof5,singlepacked,deliveredsterile)
110.350 InterstitialRingTube,diameter26mm,60º
110.351 InterstitialRingTube,diameter30mm,60º
110.352 InterstitialRingTube,diameter34mm,60º
189.566SmitSleevesCT/MRfor6mmIntrauterineTube,l=40mm,d=9mm,openended(boxof10)
189.676and following**
SmitSleevesCT/MRfor4mmIntrauterineTube,l=20mmandlonger,d=6mm(boxof10)
101.054 PerinealBar
110.305/306/307 IntrauterineTube,d=4mm,60°,L=20/40/60mm
110.290 MRLineMarkerSet* Required for interstitial treatment.**Formoreoptions,refertotheendoftheGynecologysection.
Interstitial Ring CT/MR Applicator Sets (4 mm)
ThesameInterstitialRingCT/MRApplicatorSets,featuringø4mmIntrauterineTubes
Part Number Description
110.330A02 InterstitialRingApplicatorSetd=26mm,60˚(4mm)
110.331A02 InterstitialRingApplicatorSetd=30mm,60˚(4mm)
110.332A02 InterstitialRingApplicatorSetd=34mm,60˚(4mm)
Set d=30 mm, 60º (max. 9 needles), part # 110.331 A01 Part Number Description
110.351 InterstitialRingTube,diameter30mm,60º
101.051 IntrauterineTube,length20mm,60º(6mm)
101.052 IntrauterineTube,length40mm,60º(6mm)
101.053 IntrauterineTube,length60mm,60º(6mm)
101.057 RectalRetractor,60º
189.930 FixationNutsSet(spare),Setof5
101.012 SterilizationCapsCT/MR,packof50
110.268 Obturators,Setof5
189.714 Insertion Tool
189.040 CleaningbrushSet
189.043 CleaningbrushSet
MR safe
TheInterstitialRingCT/MRApplicatorSet,basedontheRingCT/MRApplicatorSet,allowsforcombinedintracavitaryandinterstitialbrachytherapyprocedures.TheringservesasatemplatetoinsertProGuideinterstitialneedleswhentheapplicatorisinplace.Theinsertiondepthoftheneedlescanbeeasilycontrolledusingtheinsertiontool.Theneedlesareindividuallylockedinplacefortreatment.TheapplicatorisCTandMR-compatible,andenablesconformaltreatmentplanningwiththeuseoftransversalslices.TheInterstitialRingCT/MRApplicatorSetoffersaflexiblesolutiontoachieveoptimallyconformalcervicalandparametrialdosecoverage.
22 23
• Canalsobeusedasastandardintracavitaryringapplicator.• Useofneedleswithroundedtipcanreducetheriskofperforationofcriticalstructures,andisrecommended forusewithinterstitialcervixapplicators.• Non-clinicaltestinghasdemonstratedthatthetitaniumneedlesandtheneedlefixationtoolareMRConditional. Theseproductscanbescannedsafelyunderthefollowingconditions:Staticmagneticfieldupto0.23Tesla.• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanual090.720.
• Optimaldosesculptingforextendedtumorstages• Rigidneedlesandfixedapplicatorgeometry
Applicable body sites:
• Cervix• Endometrium
Vienna Ring CT/MR Applicator Set
Order Information
Vienna Ring CT/MR Appl. Set 26 mm, 60°, part # 189.699Part Number Description
189.713 ViennaRingCT/MRTube,60°(for7needles)
101.051 IntrauterineTube,l=20mm,60°
101.052 IntrauterineTube,l=40mm,60°
101.053 IntrauterineTube,l=60mm,60°
101.057 RectalRetractor,60°
189.930 Setof5FixingNuts(spare)
101.012 SterilizationCaps,CT/MR,50pieces
110.720 NeedleFixationTool,d=26mm
189.040 CleaningbrushSet
189.043 CleaningbrushSet
Vienna Ring CT/MR Appl. Set 30 mm, 60°, part # 189.792 Part Number Description
189.799 ViennaRingCT/MRTube,60°(for9needles)
101.051 IntrauterineTube,l=20mm,60°
101.052 IntrauterineTube,l=40mm,60°
101.053 IntrauterineTube,l=60mm,60°
101.057 RectalRetractor,60°
189.930 Setof5FixingNuts(spare)
101.012 SterilizationCaps,CT/MR
110.721 NeedleFixationTool,d=30mm
189.040 CleaningbrushSet
189.043 CleaningbrushSet
Vienna Ring CT/MR Appl. Set 34 mm, 60°, part # 189.569 Part Number Description
189.567 ViennaRingCT/MRTube,60°(for9needles)
101.051 IntrauterineTube,l=20mm,60°
101.052 IntrauterineTube,l=40mm,60°
101.053 IntrauterineTube,l=60mm,60°
101.057 RectalRetractor,60°
189.930 Setof5FixingNuts(spare)
101.012 SterilizationCaps,CT/MR
189.995 NeedleFixationTool,d=34mm
189.040 CleaningbrushSet
189.043 CleaningbrushSet
Accessories Part Number Description
110.720 NeedleFixationTool,d=26mm
110.721 NeedleFixationTool,d=30mm
189.995 NeedleFixationTool,d=34mm
110.025RoundPointTi.NeedleSet,1.9mmx240mm,60°,30mm(Setof5needles)
110.027RoundPointTi.NeedleSet,1.9mmx240mm,60°,40mm(Setof5needles)
110.029RoundPointTi.NeedleSet,1.9mmx240mm,60°,50mm(Setof5needles)
083.252 Obturatorforneedle(l=100mm)*
089.636 HandleforObturator
189.566*SmitSleevesCT/MR(boxof10,l=40mm,d=9mm)
101.054 PerinealBar
110.305/.306/.307 IntrauterineTube,d=4mm,60°,L=20/40/60mm*Formoreoptions,refertolastpageofthegynecologysection.
TheViennaRingCT/MRApplicatorisbasedontheCT/MRRingApplicator,enhancedwiththeadditionofnineguideholesintheringTube.TheseguideholesallowplacementofinterstitialtitaniumneedlesusingtheringTubeasaneedletemplate,whilemaintainingthetreatmentchanneloftheringTube.Theadditionofinterstitialneedlesmakesitpossibletoachieveasymmetricalterationofthedosedistribution.Theneedlesareinsertedperpendiculartotheringandinparalleltothetandem.Theapplicator’splasticandcompositefibermaterialsminimizedistortiononCTorMRimaging.TheRoundPointneedleisdesignedtominimizetissuedamageandforeaseinimplantation.Thisapplicator,developedbyrenownedclinicalexperts,offersthesolutionfortreatmentofextendedtumorstageswithanoptimiseddosewithoutthelimitationcausedbyvicinityoforgansatrisk.
24 25
• Thisapplicatorcanbesterilizedusingsteamsterilization.• Usermanual090.617.
• Fixedgeometry
Applicable body sites:
• Cervix• Endometrium
Ring CT/MR Applicator Set
Order Information
Ring CT/MR Applicator Set, part # 101.035Part Number Description
101.060 RingApplicatorSet,30°,CT/MR
101.061 RingApplicatorSet,45°,CT/MR
101.062 RingApplicatorSet,60°,CT/MR
101.038 RingTube,d=34mm,30°
101.044 RingTube,d=34mm,45°
101.050 RingTube,d=34mm,60°
101.054 PerinealBar
AccessoriesPart Number Description
189.566SmitSleeveCT/MR(length=40mm,diameter=9mm)
101.054PerinealBar(forpart#101.060/.061/.062)
101.038RingTube,d=34mm,30° (forpart#101.060)
101.044RingTube,d=34mm,45°(forpart#101.061)
101.050RingTube,d=34mm,60°(forpart#101.062)
110.303/.304/.305/.306/.307
IntrauterineTube,d=4mm,l=4030°/45°/60°
101.015 SterilizationBox
110.290 MRLineMarkerSet
Ring CT/MR Applicator Set 30°, part # 101.060Part Number Description
101.036 RingTube,d=26mm,30°
101.037 RingTube,d=30mm,30°
101.039 IntrauterineTube,l=20mm,30°
101.040 IntrauterineTube,l=40mm,30°
101.041 IntrauterineTube,l=60mm,30°
101.056 RectalRetractor,30°
101.012 SterilizingCapsCT/MR(packof50)
Ring CT/MR Applicator Set 45º, part # 101.061Part Number Description
101.042 RingTube,d=26mm,45°
101.043 RingTube,d=30mm,45°
101.045 IntrauterineTube,l=20mm,45°
101.046 IntrauterineTube,l=40mm,45°
101.047 IntrauterineTube,l=60mm,45°
101.055 RectalRetractor,45°
101.012 SterilizingCapsCT/MR(packof50)
Ring CT/MR Applicator Set 60º, part # 101.062Part Number Description
101.048 RingTube,d=26mm,60°
101.049 RingTube,d=30mm,60°
101.051 IntrauterineTube,l=20mm,60°
101.052 IntrauterineTube,l=40mm,60°
101.053 IntrauterineTube,l=60mm,60°
101.057 RectalRetractor,60°
101.012 SterilizingCapsCT/MR(packof50)
MR safe
Thisnon-metallicapplicatorhasbeendesignedusingcompositefibertubingtoeliminatedistortiononCTorMRimages.Thisenablesconformaltreatmentplanningwiththeuseoftransverseslices.Thisapplicatorhasbeendesignedwithafixedgeometrytoensureapplicatorandtreatmentintegrity.
“Weusetheringapplicatortomatch thedosimetryoftheStockholmbox.”
T.H.Knocke,M.D. UniversitätsklinikfürStrahlentherapie,Wien,Austria
26 27
Ring Applicator Set
Applicable body sites:
• Cervix• Endometrium
TheRingApplicatorsimulatestheStockholmBoxtechniqueusingaringandarigidintrauterinetube.TheabilityoftheafterloadertoaltersourcepositionanddwelltimesenablestheapplicatortobeusedtoshapesimilardosimetrytotheFletcherorManchestertechniques.Arectalretractorcanbeusedtopushtherectal/vaginalwalltoafixeddistancefromthe source.
• ApplicatorcanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.610.
Order Information
Complete Ring Applicator Set, part # 084.050Part Number Description
085.095 RingApplicatorSet,30°
085.096 RingApplicatorSet,45°
085.097 RingApplicatorSet,60°
084.072 Perineal bar
084.056 RingTube,d=34mm,30°
084.055 RingTube,d=34mm,45°
084.054 RingTube,d=34mm,60°
084.051 RingCap,d=34mm
AccessoriesPart Number Description
084.056 RingTube,d=34mm,30°(forpart#085.095)
084.055 RingTube,d=34mm,45°(forpart#085.096)
084.054 RingTube,d=34mm,60°(forpart#085.097)
084.072 PerinealBar(alreadyincludedinpart#084.050)
189.676andfollowing*
SmitSleevesCT/MRfor4mmIntrauterineTube,length20mmandlonger,d=6mm(boxof10)
*Formoreoptions,refertolastpageofthegynecologysection.
Ring Applicator Set 30°, part # 085.095Part Number Description
084.062 RingTube,d=26mm,30°
084.059 RingTube,d=30mm,30°
084.065 IntrauterineTube,length20mm,30°
084.064 IntrauterineTube,length40mm,30°
084.063 IntrauterineTube,length60mm,30°
084.316 RectalRetractor,30°
084.053 RingCap,d=26mm
084.052 RingCap,d=30mm
084.158 SterilizingCaps,3.2mm(50pcs)
Ring Applicator Set 45°, part # 085.096Part Number Description
084.061 RingTube,d=26mm,45°
084.058 RingTube,d=30mm,45°
084.068 IntrauterineTube,length20mm,45°
084.067 IntrauterineTube,length40mm,45°
084.066 IntrauterineTube,length60mm,45°
084.335 RectalRetractor,45°
084.053 RingCap,d=26mm
084.052 RingCap,d=30mm
084.158 SterilizingCaps,3.2mm(50pcs)
Ring Applicator Set 60°, part # 085.097Part Number Description
084.060 RingTube,d=26mm,60°
084.057 RingTube,d=30mm,60°
084.070 IntrauterineTube,length20mm,60°
084.069 IntrauterineTube,length40mm,60°
084.063 IntrauterineTube,length60mm,60°
084.316 RectalRetractor,60°
084.053 RingCap,d=26mm
084.052 RingCap,d=30mm
084.158 SterilizingCaps,3.2mm(50pcs)
28 29
• TheVaginalMoldChannelassembliesarereusable,andcanbesterilizedusingsteamsterilizationandEtO.• TheVaginalMoldTubesareforsingleuseonly,andcanbesterilizedusingEtO.• Usermanual090.708.
• Tailoredirradiation• Precisedosedistribution
Applicable body sites:
• Vagina• Cervix
Vaginal Mold Applicator Set
Vaginal Mold Applicator Set, part # 189.018 Part Number Description
189.020 VaginalMoldChannel1Assembly
189.021 VaginalMoldChannel2Assembly
189.022 VaginalMoldChannel3Assembly
189.019 VaginalMoldTubesSet(30pieces)
084.158 SterilizingCaps(50pieces)
Order Information
TheVaginalMoldApplicatorSetwasdevelopedinclosecooperationwithCenterOscarLambretinLille,France.ItenablestheusertoapplytheFrench“moulage”,orInstitutGustaveRoussy,techniqueforafterloading.Theaimofthismethodispersonalizedirradiationwithprecisedosedistributionandgoodpatienttolerance.Thesetconsistsofthree,mechanicallycoded,stainlesssteelchannelassemblieswhichcanbeeasilyconnectedtotheflexibleVaginalMoldTubes.Theseareembeddedinthecustomizedmold.
30 31
Vaginal CT/MR Multi Channel Appl. Set, part # 110.750Part Number Description
101.002 Intravaginal Tube
110.752 Setofcylindercomponents,Ø25mm(features6surfacechannels)
110.756 Setofcylindercomponents,Ø30mm(features8surfacechannels)
110.761 Setofcylindercomponents,Ø35mm(features8surfacechannels)
101.012 SterilizingCapsCT/MR(packof50)
Order Information
AccessoriesPart Number Description
110.800*CatheterSetwithCollar6Fx293mm(deliveredsterileandforsingleuseonly)
110.766 Setofcylindercomponents,Ø40mm(features10surfacechannels)
101.003 CT/MRIntrauterineTube15°,L=40mm,Ø6mm
101.004 CT/MRIntrauterineTube30°,L=60mm,Ø6mm
101.005 CT/MRIntrauterineTube45°,L=80mm,Ø6mm
110.787**CTexpansionSet,featuringthintitaniumIntrauterineTubesL=40,60and80mm
110.773 PerinealBarSet
110.771 Setoffixationsscrews(5pcs)
110.778 ApplicatorClampAdapterSet
101.015 SterilizationBox* Required for use.**WhenusingTitaniumIntrauterineTubestheapplicatorisMRunsafe.
• Thecenterofthesurfacechannelsislocated5mmunderneaththecylindersurface.• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanualforapplicator777.00171.• Usermanualforcatheters777.00172.
Vaginal CT/MR Multi Channel Applicator Set
Precise Dose Delivery Solution
• Reachwhereitmattersmost• Uniquetreatmentprecision• Practicaldesign
Applicable body sites:
• Vagina• Cervix• Endometrium
MR safe
ThenewVaginalCT/MRMultiChannel(VCMC)Applicatoristhefirstapplicatorforvaginalbrachytherapyinthetreatmentofendometrialandothergynecologiccancersthatfeaturescurvedtreatmentchannelsintheapplicator’stip.Bybringingdosimetrymeasurablyclosertothevaginalvault,conformityandtreatmentprecisioncanbedramaticallyimproved.Thetreatmentchannelscanalsobeloadedseparately,andaddtotheabilitytotreatmorecomplexoradvanced tumors.
Fortreatment,acatheterisinsertedintherequiredtreatmentchannelsandconnectedtotheafterloader.Thesechannelsarelocatedimmediatelyunderneaththesurfaceoftheapplicator,toprovideoptimalcontroloverthedosimetryatthetargetandaroundorgansatrisk.
TheVCMCapplicatorcanbeseamlesslyintegratedwithOncentraBrachy’sApplicatorModelingmoduleandLibraryPlans.ThecombinationoftheVCMCapplicatorwithOncentraBrachyoffersanaccurateandreproducible3Dplanningsolutionforvaginalbrachytherapy.
32 33
Vaginal CT/MR Applicator Set
• Reproducibledosimetry• Easilyadaptabletopatientanatomy
Applicable body sites:
• Vagina• Cervix• Endometrium• Rectum
Complete Set, part # 101.001 Part Number Description
101.002 Vaginal Tube
101.003 ApplicatorTube15°,40mm
101.004 ApplicatorTube30°,60mm
101.005 ApplicatorTube45°,80mm
101.007 Setof4cylinders,20mm
101.008 Setof4cylinders,25mm
101.009 Setof4cylinders,30mm
101.010 Setof4cylinders,35mm
101.006 Cylinderfixation
101.013 PerinealBar
101.012 SterilizingCapsCT/MR(packof50)
Order Information
AccessoriesPart Number Description
101.011 Setof4cylinders,40mm
189.566 SmitSleeveCT/MR(length=40mm,diameter=9mm)
101.015 SterilizationBox
101.149 KnobPPSU**Minimumorderquantityis5pieces.
• Thisapplicatorcanbesterilizedusingsteamsterilization.• Usermanual090.612.
MR safe
TheVaginalCT/MRApplicatorSetisdesignedfortreatmentofthevaginalcuff.Thiseasytouseapplicatorisavailableindifferentcylinderdiameters,toreducethesurfacedose.Byvaryingthenumberofsegmentsofthecylinder,thelengthofthecylindercanbeadaptedtoclinicalneeds.Thenon-metallicmaterialsoftheapplicatorsetsupportitsuseincombinationwithCTandMRimagingmodalities.
34 35
Ti Vaginal Cylinder Applicator Set
• Embeddedmarkers• Strongandlightweight
Applicable body sites:
• Vagina• Cervix• Endometrium• Rectum
Ti Vaginal Cylinder Applicator Set, part # 137.400Part Number Description
137.194 CylinderSet,d=20mm
137.195 CylinderSet,d=25mm
137.196 CylinderSet,d=30mm
137.416 Intra-vaginalapplicatorTube(Ti)
137.402 Intra-vaginal/intra-uterineTube,40mm(Ti)
137.403 Intra-vaginal/intra-uterineTube,60mm(Ti)
137.404 Intra-vaginal/intra-uterineTube,80mm(Ti)
137.401 Perineal bar 1
137.415 SpringlockTube(Ti)
137.570 Closingcaps(25pcs)
Order Information
AccessoriesPart Number Description
137.197 CylinderSet,d=15mm
137.198 CylinderSet,d=35mm
137.199 CylinderSet,d=40mm
137.573 Sterilizationtray
189.677/679/682 Smit Sleeve
• Theapplicatorcanbesterilizedusingsteamsterilization.• Usermanual777.00118.
TheTitanium(Ti)VaginalCylinderApplicatorisaneasysolutionforintracavitaryvaginaltreatments.WhenusedwithanIntrauterineTube,theVaginalApplicatoralsooffersasimplesolutionfortreatmentofthecervix,rectumorendometrium.Theembeddedtitaniummarkersinthecylindersegmentssupportvisualizationoftheinsertedapplicatorwhileminimizingcontaminationrisk.ThesetisavailableinarangeofdifferentdiametersandcurvaturesoftheIntrauterineTube,toprovideindividuallyoptimizedtreatmentoptionsanddosedistribution.
36 37
Shielded Cylindrical Applicator Set
Applicable body sites:
• Vagina• Rectum Shielded Cylindrical Applicator Set, part # 084.320
Quantity Part Number Description
1 084.321 CentralTube
1 084.329 TungstenShielding,180°
2 084.328 TungstenShielding,90°
1 084.322 Cylinder,d=25mm
1 084.323 Cylinder,d=30mm
1 084.324 Cylinder,d=35mm
1 084.325 Cylinder,d=40mm
1 084.327 FixingNut
1 084.158 SterilizingCaps,3.2mm(50pcs)
1 084.330 SterilizationBox
• Usermanual090.609.
AccessoriesPart Number Description
084.348 Plasticfiller,90°geometry
084.349 Plasticfiller,180°geometry
Order Information
TheShieldedCylindricalApplicatorisdesignedforintracavitarytreatmentsinwhichpartialshieldingisrequiredtoreducethedosetocriticalorgans.Theshieldingpositionscanbedefinedbytheuserthroughtheuseoftungstenalloysegmentswithdifferentshieldingangles.Markersindicatethepositionoftheshielding.
38 39
• ApplicatorcanbesterilizedusingEtO.• Usermanual090.601.
Miami Vaginal Applicator Set
Applicable body sites:
• Vagina• Cervix• Endometrium• Rectum
Order Information
Miami Applicator Set, part # 085.210Part Number Description
085.211 CentralTube
084.455 Intrauterinetube,straight
084.456 Intrauterinetube,15°
084.457 Intrauterinetube,30°
085.212 Cylinder,d=30mm,withmarker
085.213 CylinderSleeve,d=35mm
085.214 CylinderSleeve,d=40mm
085.218 Coneinsert
006.182 Screwdriver
598.027 AllenKeyScrewdriver3mm
083.147 SterilizingCaps,1.9mm(50pcs)
084.158 SterilizingCaps,3.2mm(50pcs)
189.676andfollowing*
SmitSleevesCT/MRfor4mmIntrauterineTube,length20mmandlonger,d=6mm(boxof10)
*Formoreoptions,refertotheendoftheGynecologysection.
TheMiamiVaginalApplicatorSetwasdevelopedincooperationwiththeUniversityofMiami.Theapplicatorcontains6lateraltubes,whichareequallyspacedaroundthesurfaceofthecylinderforoptimizedtreatment.
Acentraltubeanddifferentintrauterinetubesexpandthepossibletreatmentoptions.Threedifferentcurvaturesofintrauterinetubesareincludedandadjusttotheuterinelength.Thevaginalcylinderis30mmindiameterwithcylindersleevesof35and40mm.Thisenablesversatilityinthetreatmentofvaginal,cervical,uterineandrectalcarcinomas.
40 41
• ApplicatorcanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.606
Vaginal Applicator Set
• Reproducibledosimetry• Easilyadaptabletopatientgeometry
Applicable body sites:
• Vagina• Cervix• Endometrium• Rectum
Order Information
Vaginal Applicator Set, part # 084.350Part Number Description
084.002 Vaginal Tube
084.003 IntrauterineTube,length40mm,15°
084.004 IntrauterineTube,length60mm,30°
084.005 IntrauterineTube,length80mm,45°
084.010 CylinderLockingPipe
084.351 4Cylinderparts,d=0mm,withmarker
084.352 4Cylinderparts,d=25mm,withmarker
084.353 4Cylinderparts,d=30mm,withmarker
084.354 4Cylinderparts,d=35mm,withmarker
084.158 SterilizingCaps,3.2mm(50pcs)
084.089 SterilizationBox,for084.350
AccessoriesPart Number Description
084.008 PerinealBar
084.009 CervicalStopper
084.355 4Cylinderparts,d=40mm,withmarker
084.875 4Cylinderparts,d=15mm,withmarker
101.149 KnobPSU
189.676andfollowing*
SmitSleevesCT/MRfor4mmIntrauterineTube,length20mmandlonger,d=6mm(boxof10)
*Formoreoptions,refertotheendoftheGynecologysection.
TheVaginalApplicatorSetforintracavitarytreatmentisveryuser-friendly.Thesetisavailablewiththreedifferentlengthsandcurvaturesoftheintrauterinetubetoprovideadditionaltreatmentoptions.Thecylindersareavailableindifferentdiameterstooptimizethedosedistributionandreducethemucosaldose.
TheVaginalApplicatorcanbeusedtotreatvaginalcuff,cervix,rectumorendometriumwhenusedwithanintrauterine tube.
42 43
• Usermanual090.611.
Adjustable Cervix Applicator Set
Other applicable body sites:
• Cervix• Endometrium• Vagina• Rectum
Order Information
Adjustable Cervix Applicator Set, part # 084.450Part Number Description
084.455 IntrauterineTube,straight
084.456 IntrauterineTube,angle15°
084.457 IntrauterineTube,angle30°
084.451 Cylinder,d=20mm,withmarker
084.452 Cylinder,d=25mm,withmarker
084.453 Cylinder,d=30mm,withmarker
084.454 Cylinder,d=35mm,withmarker
084.158 SterilisingCaps,3.2mm(packof50)
TheAdjustableCervixApplicatorforintracavitarytreatmentisveryuser-friendly.Thecylindersareavailableindifferentdiameterstooptimizethedosedistributionandreducethemucosaldose.Theintrauterinetubeisavailableinthreecurvatureswithdifferentlengths.Conjointly,thisgivesaversatileapplicatorforcervical,uterine,vaginalandrectalcancer treatment.
44 45
Norman Simon Applicator Set
Applicable body sites:
• Endometrium
• Regulatoryapprovalforthisapplicatorispending.• ForusewithmicroSelectronafterloaderonly.• TheapplicatorscanbesterilizedusingEtOsterilization.Theincludedobturatorscanalsobesterilized usingsteamsterilization.
• X-Raycatheterset#089.097facilitateuseof10-18applicators.• Usermanual090.616.
TheNormanSimonApplicatorSetisintendedtoduplicatethelowdoserateHeymanPackingtechniquefortreatmentofendometrial cancer.
Order Information
Basic Norman Simon Applicator Set, part # 089.079Quantity Part Number Description
5 089.191 NormanSimonApplicator1,d=6mm
5 089.192 NormanSimonApplicator2,d=6mm
5 089.193 NormanSimonApplicator3,d=6mm
5 089.194 NormanSimonApplicator4,d=6mm
5 089.195 NormanSimonApplicator5,d=6mm
5 089.196 NormanSimonApplicator6,d=6mm
5 089.197 NormanSimonApplicator7,d=6mm
5 089.198 NormanSimonApplicator8,d=6mm
5 089.199 NormanSimonApplicator9,d=6mm
1 089.096 X-RayCatheterSet(1-9),NormanSimonApplicators
AccessoriesPart Number Description
083.272 InsertionObturatorfor1.9mmNeedlex294mm
46 47
Rotte Endometrial Applicator Set
• Excellentreproducibilityofdosedistribution• Straightforwardworkflow
Applicable body sites:
• Endometrium
Basic Rotte Applicator Set, 32 mm, part # 084.230Part Number Description
084.231 ApplicatorTube1,RightUterus
084.232 ApplicatorTube2,LeftUterus
084.158 SterilisingCaps,3.2mm(50pcs)
Complete Set, part # 084.434Part Number Description
084.435 BasicRotteApplicatorSet,20mm
084.230 BasicRotteApplicatorSet,32mm
084.436 BasicRotteApplicatorSet,40mm
084.437 BasicRotteApplicatorSet,50mm
084.158 SterilisingCaps,3.2mm(50pcs)
Accessories for Gynecology Applicators
Intrauterine Tube (4 mm)
Theø4mmIntrauterineTubesarespecificallydevelopedforusewithgynecologicCT/MRapplicators.Theirthindiameterfacilitateseasyinsertion,whiletheinnerlumenallowsuseofMRLineMarkerstovisualizeandreconstructthesourcepathonMRI.
• ø6mmSmitSleevescanbeusedwiththe4mmIntrauterineTubes.• TheIntrauterineTubescanbesterilizedusingsteamsterilizationandEtO.• Usermanual777.00088.
Intrauterine Tube for use with:
189.
730
Flet
cher
CT/
MR
Appl
icat
or
110.
270
Utr
echt
Int
erst
itia
l
CT/M
R A
pplic
ator
101.
020
Stan
dard
CT/
MR
Ap-
plic
ator
101.
035
CT/M
R R
ing
Appl
icat
or
189.
569/
699/
792
Vien
na R
ing
CT/M
R
Appl
icat
or
110.
330/
331/
332
Inte
rsti
tial
Rin
g
CT/M
R A
pplic
ator
Part Number Description
110.296 IntrauterineTube(4mm),15ºIncl.SpecialStopper(part#110.326) x x
110.298 IntrauterineTube(4mm),30ºIncl.SpecialStopper(part#110.326) x x
110.300 IntrauterineTube(4mm),45ºIncl.SpecialStopper(part#110.326) x x
110.302 IntrauterineTube(4mm),l=50mm,40ºIncl.SpecialStopper(part#189.768) x
110.303 IntrauterineTube(4mm),l=40mm,30º x
110.304 IntrauterineTube(4mm),l=40mm,45º x
110.305 IntrauterineTube(4mm),l=20mm,60º x x x
110.306 IntrauterineTube(4mm),l=40mm,60º x x x
110.307 IntrauterineTube(4mm),l=60mm,60º x x x
OptionalRectalRetractors,foruseincombinationwithIntrauterineTube4mmandspecificapplicator
110.315 RectalRetractor30mmwithslot x x
110.335 RectalRetractor40mmwithslot x x
101.057 Rectalretractor60° x x
Nospecialrectalretractorrequired x x
TheRotteEndometrialApplicator(orRotte“Y”applicator)hasbeendevelopedwithProfessorK.RotteoftheUniversitäts-Frauenklinik,Würzburg,Germany,andisspecificallydesignedforhighdoseratetreatmentoftheendometrium.Theapplicatoriseasytoinsert,usingtwoopposedIntrauterineTubes.TheIntrauterineTubescanbelockedinpositionwithasingleaction.Oncelocked,theapplicatorhasafixedgeometrywhichprovidesenexcellentreproducibilityofthedosedistribution.TheRotteEndometrialApplicatoroffersatreatmentalternativeforthe`Heyman’packingtechnique.
• Usermanual090.620.
48 49
MR Line Marker Set
TheMRLineMarkerisusedtomakethesourcepathofgynecologicCT/MRapplicatorsvisiblewithMR-imaging.TheLineMarker,consistingofaplastictubetobefilledwithfluid,isplacedinsidethesourcechanneloftheapplicators.ThesetcontainsfourLineMarkers.
• Deliverednon-sterileandnotfilledwithfluid.• Usermanual777.00081.
Smit Sleeve, ø 6 mm
Smit Sleeve, ø 9 mm
Smit Sleeve
TheSmitSleeveisdesignedforfractionatedendometrialtreatment.TheSmitSleeveisaplastictubewithdrainageholesthatisinsertedintothecervicalosandsuturedinplacepriortothefirsttreatment.
WiththeSmitSleevethecervixremainsdilatedforsubsequentapplicatorinsertionsthroughoutthecourseoftreatment.TheSmitSleeveprovidestissuespacingtoreducemucosaldose.Italsoactsasacervicalstopper.
• Canremaininplaceupto28days.• AllSmitSleevesareCTandMRcompatible.• Comesterilized,aresingle-packed,andforsingleuseonly.• Usermanual090.712.
Smit Sleeve, ø 6 mm (Boxes of 10)
ForIntrauterineTubesuptoø4mm
Part Number Description
189.676 SmitSleeve,l=20mm
189.677 SmitSleeve,l=40mm
189.679 SmitSleeve,l=60mm
189.681 SmitSleeve,l=70mm
189.682 SmitSleeve,l=80mm
189.683 SmitSleeve,l=100mm
Part Number Description
110.290 MRLineMarkerSet
Smit Sleeve, ø 9 mm (Box of 10)
ForIntrauterineTubesofø6mm
Part Number Description
189.566 SmitSleeveCT/MR,l=40mm
MR safe
50 51
Bronchus Lumencath Applicator Set 52
Fritz Adjustable Intralumenal Applicator Set 54
Esophagus Bonvoisin-Gérard Esophageal Applicator Set 56
Esophageal Applicator Set 58
Alternative for Esophageal brachytherapy Fritz Adjustable Intralumenal Applicator Set 54
Bronchus & Esophagus
52 53
•Lumencathcatheterscomesterilized,aresingle-packed,andareforsingleuseonly.•Theminimumcurvatureradiusofthecathetersis20mm.•Centimeterscaleavailableoncatheterover85cmfromdistalend.•Thefixingmaskincludedcanbeusedforapplicatorimmobilization.•FormicroSelectronnotransfertubeisrequired:theapplicatorsetcontainsanadapterthatconnectsthe Lumencath catheter directly to the afterloader. • ForFlexitron,adapter#137.064isrequiredforuse.• Usermanual090.717.
Lumencath Applicator Set
• Accuratecatheterplacementthroughvisualguidance• Optimalcontroloverinsertiondepth• Cathetersdeliveredsterilizedforimmediateclinicaluse
Applicable body sites:
• Bronchus• BileDuct• Bladder
Order Information for microSelectron
5F, 100 cm Set, part # 189.797Quantity Part Number Description
2 189.773 Lumencath5F,I=100cm(packof5)
10 083.029 GuideWire,l=260cm
1 089.400 X-RayCatheterSet,l=100cm
3 080.024 ApplicatorAdapter5F
1 084.099 FixingMask*Whenorderedseparatelytheminimumorderquantityis2packs.
5F, 150 cm Set, part # 189.798Quantity Part Number Description
2 189.774 Lumencath5F,I=150cm(packof5)
10 083.029 GuideWire,l=260cm
1 089.510 X-RayCatheterSet,l=150cm
3 080.024 ApplicatorAdapter5F
1 084.099 FixingMask*Whenorderedseparatelytheminimumorderquantityis2packs.
Order Information for Flexitron
5F, 140 cm Set, part # 110.600Quantity Part Number Description
2 110.601 Lumencath5F,I=1400mm(packof5)
10 083.029 GuideWire,l=260cm
1 137.673 X-raycatheter1400mm-channel1
3 137.064 ApplicatorAdapter5F
1 084.099 FixingMask*Whenorderedseparatelytheminimumorderquantityis2packs.
AccessoriesPart Number Description
189.773 Lumencath5F,100cm(packof5)
189.774* Lumencath5F,150cm(packof5)
189.771 Lumencath6F,100cm(packof5)
189.772* Lumencath6F,150cm(packof5)
110.601 Lumencath5F,140cm(packof5)
137.064** Adaptorfor5Fcatheters
137.674 X-raymarker1400mm-channel2*CanonlybeusedwithmicroSelectron.**CanonlybeusedwithFlexitron.
6F, 100 cm Set, part # 189.795Quantity Part Number Description
2 189.771 Lumencath6F,I=100cm(packof5)
10 083.029 GuideWire,l=260cm
1 089.400 X-RayCatheterSet,l=100cm
3 080.026 ApplicatorAdapter6F
1 084.099 FixingMask*Whenorderedseparatelytheminimumorderquantityis2packs.
6F, 150 cm Set, part # 189.796Quantity Part Number Description
2 189.772 Lumencath6F,I=150cm(packof5)
10 083.029 GuideWire,l=260cm
1 089.510 X-RayCatheterSet,l=150cm
3 080.026 ApplicatorAdapter6F
1 084.099 FixingMask*Whenorderedseparatelytheminimumorderquantityis2packs.
MR safe*
TheLumencathApplicatorSetisspeciallydesignedtofitintothechannelofabronchoscopeforendobronchialbrachytherapy.TheLumencathtreatmentcathetercanthereforebepositionedintothetreatmentareaunderdirectvisualcontrol.Thelowfrictionmaterialofthecatheterallowsoptimalflexibilityduringinsertionaswellasasmoothtransferofthesourceduringtreatment.TheLumencathtreatmentcathetersareequippedwithcentimeterscalesforoptimalcontrolovertheinsertiondepth.TheLumencathApplicatorSetcanalsobeusedtotreatvariousotherbodysitesthatallowinsertionofsuchflexiblecatheters.*PleasenotethattheconnectorandfixingmaskarenotMRsafe.
54 55
• Theminimumbendingradiusis25mm.• Theflexibletreatmenttubecomessterilizedforimmediateclinicaluse.• Notransfertubeisrequired.Theapplicatorsetconnectsdirectlytotheafterloader.• ThisapplicatorsetcanonlybeusedonmicroSelectronafterloaders.• TheapplicatorsetcanbesterilizedusingEtO.• Usermanual090.636.
Order Information
100 cm Set, part # 085.009Part Number Description
089.401 X-RayCatheterno.1,100cm
084.410 FixingMaskSet
039.015 GuideWire,l=1.5m
084.158 SterilizingCaps,3.2mm
085.028 FlexibleTube,2incisions
085.029 FlexibleTube,3incisions
085.015 AdjustableIntralumenal,100cm
094.361 SterilizationAdviceChart
AccessoriesPart Number Description
189.004 EsophagealFixingMaskSet
Fritz Adjustable Intralumenal Applicator Set
• ExpandableouterTubeforimmobilizationandcenteringwithinthelumen• Allowssufficientairflowaroundtheapplicatorforpatientcomfort
Applicable body sites:
• Esophagus• Trachea• Bronchus(MainStem)
150 cm Set, part # 085.070Part Number Description
089.511 X-RayCatheterno.1,150cm
084.410 FixingMaskSet
039.015 GuideWire,l=1.5m
084.158 SterilizingCaps,3.2mm
085.028 FlexibleTube,2incisions
085.029 FlexibleTube,3incisions
085.073 AdjustableIntralumenal,150cm
094.361 SterilizationAdviceChart
TheFritzAdjustableIntralumenalApplicatorisdesignedfortreatmentoftheesophagus,tracheaorbronchus(mainstem).Afterinsertion,theoutertubingexpandstocentertheapplicator,assistinginimmobilizationandcenteringoftheapplicatorwithinthelumen.Thepatientcanthereforebetreatedcomfortablywithsufficientairflowaroundtheapplicator.
“TheFritzAdjustableIntralumenalApplicatorwasdevelopedbecauseitwasnecessary tocentertheapplicatorwithinthemainstembronchustoavoidahighmucosaldose.”
Prof.Dr.Fritz Marienkrankenhaus,Siegen,Germany
56 57
• Notransfertubeisrequired.Theapplicatorsetconnectsdirectlytotheafterloader.• SeparateapplicatorsetsareavailableforFlexitronandmicroSelectronafterloaders.• Refertotheapplicablemanualforsterilizationadvice.• Usermanual:090.628for#085.035;777.00116for#137.258.
Order Information for microSelectron
Order Information for Flexitron
Complete Set, part # 085.035Part Number Description
085.036 Treatment Tube
085.037 BougieTube,d=13mm
189.004 EsophagealFixingMaskSet
592.973 GuideWire,l=2m
089.401 X-RayCatheter#1,100cm
084.170 SterilizingCaps,6mm,50pieces
094.353 SterilizationAdviceChart
Complete Set, part # 137.258Part Number Description
137.259 1400mmflexibletreatmentcatheter
137.261 BonvoisinGerardesophagealappl.,18F(Ø6mm)
137.263 BonvoisinGerardesophagealappl.,24F(Ø8mm)
137.265 BonvoisinGerardesophagealappl.,30F(Ø10mm)
137.276 ApplicatorfixationMask
137.277 Applicatorcleaningaccessories
137.279 ApplicatorMaskstrap(packof5)
Bonvoisin-Gérard Esophageal Applicator Set
• Easyapplicatorinsertionusingendoscopy• Excellentsourcecentering• Radio-opaqueapplicatormarkingassistsplacementandlocalization Accessories for microSelectron Set
Part Number Description
085.033 BougieTube,d=10mm
085.034 BougieTube,d=15mm
Accessories for Flexitron SetPart Number Description
137.267 Applicator36F(Ø12mm)
137.270 Applicator45F(Ø15mm)
137.278 GuideWirePackof5pcs(sterile)
137.064** Adaptorfor5Fcatheters**RequiredforusewithFlexitron.
TheBonvoisin-GérardEsophagealApplicatorisdesignedtoassistinthetreatmentofanendoscopicallyobstructedesophagus.Byusingthisspecialdilationapplicatorwithtaperedflexibletipthetreatmentareacanbereachedbybouginage.Thebougietubewillalsoassistincenteringthetreatmentcatheterinternallytominimizethemucosaldose,whileensuringoptimaldepthdosepenetrationoftheesophagealwall.Radiographicmarkersonthebougietubeaidinfluoroscopicplacementandlocalizationoftheapplicator.
58 59
• Theminimumcurvatureis25mm.• Notransfertubeisrequired.Theapplicatorconnectsdirectlytotheindexer.• ThisapplicatorsetcanonlybeusedonmicroSelectronafterloaders.• TheapplicatorcanbesterilizedusingEtO.• Usermanual090.607.
Esophageal Applicator Set
• Specificouterapplicatorsurfacereducesdosetomucosa• Easyapplicatorinsertionusingfluoroscopy
Order Information
8 mm, 100 cm Set, part # 085.005Quantity Part Number Description
2 085.006 EsophagealApplicator,d=8mm,100cm
1 189.004 EsophagealFixingMaskSet
1 039.015 GuideWire,l=1.5m
1 089.401 X-RayCatheter#1,100cm
1 084.170 SterilizingCaps,6mm,50pieces
1 094.356 SterilizationAdviceChart
6 mm, 100 cm Set, part # 084.011Quantity Part Number Description
2 084.012 EsophagealApplicator,d=6mm,100cm
1 189.004 EsophagealFixingMaskSet
1 039.015 GuideWire,l=1.5m
1 089.401 X-RayCatheter#1,100cm
1 084.170 SterilizingCaps,6mm,50pieces
1 094.356 SterilizationAdviceChart
6 mm, 150 cm Set, part # 085.055Quantity Part Number Description
2 085.056 EsophagealApplicator,d=6mm,150cm
1 189.004 EsophagealFixingMaskSet
1 039.015 GuideWire,l=1.5m
1 089.511 X-RayCatheter#1,150cm
1 084.170 SterilizingCaps,6mm,50pieces
1 094.356 SterilizationAdviceChart
AccessoriesPart Number Description
085.007 Esophagealapplicator,d=8mm,150cm(forpart#085.055)
085.006 Esophagealapplicator,d=8mm,100cm(forpart#084.011)
084.012 Esophagealapplicator,d=6mm,100cm(forpart#085.005)
189.004 EsophagealFixingMaskSet
TheEsophagealApplicatorisdesignedfordirectinsertionintotheesophagus.Theapplicatorcanbepositionedorallyunderfluoroscopyorendoscopicexamination.Itisprovidedwithanadditionalouterlayertoreducethedosetotheesophagealmucosaandsupportapplicatorintegrity.
60 61
Breast Templates Breast CT/MR Template Set 62
Kuske Breast Applicator Set 64
OncoSmart Catheters OncoSmart Catheter System 66
Breast
62 63
Breast CT/MR Template Set
• Supportsoptimizedimplant:fastandeasy• Moreconvenientforthepatient• CTandMRcompatible
Order Information
Breast CT/MR Template Set, part # 110.518Part Number Set components
110.517 Adjustabletemplatebridge
110.536 Setoftemplatelevers
110.516 DoublePlane,10mmTemplatePairs,5Pairs:3-4,4-5,5-6,6-7and7-8holes.
110.519 DoublePlane,16mmTemplatePairs,5Pairs:3-4,4-5,5-6,6-7and7-8holes.
110.520 TriplePlane,10mmTemplatePairs,4Pairs:3-4-5,4-5-6,5-6-7and6-7-8holes.
110.523 TriplePlane,16mmTemplatePairs,4Pairs:3-4-5,4-5-6,5-6-7and6-7-8holes.
AccessoriesPart Number Set components
110.528 DoublePlane,12mmTemplatePairs,5Pairs:3-4,4-5,5-6,6-7and7-8holes.
110.529 DoublePlane,14mmTemplatePairs,5Pairs:3-4,4-5,5-6,6-7and7-8holes.
110.530 DoublePlane,18mmTemplatePairs,5Pairs:3-4,4-5,5-6,6-7and7-8holes.
110.532 TriplePlane,12mmTemplatePairs,4Pairs:3-4-5,4-5-6,5-6-7and6-7-8holes.
110.533 TriplePlane,14mmTemplatePairs,4Pairs:3-4-5,4-5-6,5-6-7and6-7-8holes.
110.534 TriplePlane,18mmTemplatePairs,4Pairs:3-4-5,4-5-6,5-6-7and6-7-8holes.
various* Proguideneedles5Fand6F
various* Metalneedlesø1.5andø1.9mm
various* OncoSmart catheter system* See relevant section
• ThebreastCT/MRTemplateSetcanbesterilizedusingsteamsterilization.• Usermanual777.00141.
MR safe
TheBreastCT/MRTemplateSetisdesignedtofacilitatemulti-catheterimplants,usingCTandMRimagingmodalities.Thelightweightdesignofthetemplateprovidespatientcomfortandmakeshandlingthetemplateduringtheneedleinsertionsimpleandquick.Arangeoftemplateconfigurationsareincludedintheset,offeringachoiceintemplatesthatbestfittheimplant.Eachtemplateconfigurationprovidesadosedistributionaccordingtothe‘ParisDosimetrySystem’.
64 65
Kuske Breast Applicator Set
• Designedforoptimalfitwithpatientanatomy• Optimaltargetcoverage,includingwidevolumes• Excellentdoseconformity
Order Information
Kuske Breast Applicator Set, part # 189.006Quantity Part Number Description
1 189.012 KuskeBreastTemplateSet
4 189.307 LeaderInsertionNeedle,1.5x200mm(boxof36)
1 189.231 Insertion Tool
6 189.445CT/MRFlexibleImplantTube,6F, SingleLeader,30cm(boxof36)
1 189.458 RadioLucentButtonwhite,6F(boxof72)
1 189.460 RadioLucentButtonblack,6F(boxof72)
1 189.462 RadioLucentButtonred,6F(boxof72)
1 189.464 RadioLucentButtonblue,6F(boxof72)
1 189.466 RadioLucentButtongreen,6F(boxof72)
1 189.041 CleaningBrushø3x100(Setof3)
1 189.043 CleaningBrushø6.5x100(Setof3)
1 189.367 CutterFlexibleImplants
AccessoriesPart Number Description
594.456 EmergencyButtonCutter
189.468 Radio-LucentButtonyellow,6F,(boxof72)
189.470 Radio-LucentButtonbrown,6F,(boxof72)
089.420 X-RayCatheterSet,30cm(1-18)
030.100 Push-FitDisconnectionTool
089.348 KinkProtectionTubefor6FFlexible*
089.345 KinkProtectionTubeforTransferTube**Minimumorderquantityis50pieces.
Kuske Breast Template Set, part # 189.012Quantity Part Number Description
1 189.015 KuskeBreastTemplateHolder
1 189.026 LeftTemplateClamp
1 189.027 RightTemplateClamp
1 189.046 ImplantTemplate
1 189.047 TargetTemplate
1 189.048 GuidingTemplate
2* 189.222 ImplantTemplateFixationNut
2 189.223 BridgeFixationNut
2 189.224 TargetTemplateFixationNut
2 189.225 SlideFixation
2* 189.226 GuidingTemplateFixationNut
1 094.446 SterilizationAdviceChart*Whenorderedseparately,theminimumorderquantityis5pieces.
• TheKuskeBreastTemplateSetcanbesterilizedusingEtO.• Usermanual090.706.
MR safe*
TheKuskeBreastApplicatorSetwasdevelopedinclosecooperationwithDr.RobertKuske.TheadjustabletemplatewithintegratedguidingplateensuresexactplacementofneedlesandOncoSmartCathetersorFlexibleImplantTubes.Thesinglelargetemplatepairwithspecialholegeometryensuresoptimalcoverageofthecompletetargetvolume.Markersareintegratedinthetemplatetoaidtheimagingproceduresandprovidetheopportunitytooptimizepositioningofthetemplate.*PleasenotethattheconnectorandfixingmaskarenotMRsafe.
“Theapplicatorenablestheusertocreatelargevolumebreastimplants.Theadjustabletemplatehasan integratedguidingtemplatewhichensuresanexactplacementofneedlesandflexibleimplantsorOncoSmart Catheters.Alsothesinglelargetemplatehasaspecialhole-geometry.Theresultisanexcellentcoverageof thetargetvolumeandanoptimizedconformitywiththepatient‘sanatomy.”
R.KuskeM.D. ArizonaOncologyServices-Scottsdale,AZ,USA
66 67
• TheCatheterSetcontentsareforsingleuseonly,andcomesterilized,withtheexceptionofthe4FProGuide NeedlesandtheStoptags.• Setcontentsarepackedper6items,exceptfor#189.802.• Usermanual090.709.
Order Information
OncoSmart Catheter System
• Supportingoutpatienttreatments• Minimumpatientdiscomfortbetweenfractions• Quickandaccuratereconnectionforfollow-upfractions
Applicable body sites:
• Breast•Head&Neck• Sarcomas• Tongue
OncoSmart Flange Molding Set, part # 189.016Quantity Part Number Description
1 189.320 FlangeMoldingTool
2 417.018 Li-ionBatteryPack
1 417.006 BatteryChargeStation
1 189.316 FlangeMoldingCutter
1 189.367 CutterFlexibleImplants
1 189.369 SparepartsetFlangeMoldingTool
CT/MR OncoSmart Catheter Set, part # 189.410Quantity Part Number Description
5 189.418CT/MROncoSmartCatheterSet,L=240mm(contains18Flexibleimplanttubes,4FProguideneedles(240mm),stoptags,buttons,andinsertionneedles(200mm))
1 189.016 OncoSmartFlangeMoldingSet
OncoSmart Introduction Set for microSelectron, part # 103.111Part Number Description
189.410 CT/MROncoSmartCatheterSystem
189.012 KuskeBreastTemplateSet
189.231 Insertion Tool
189.036 CT-MarkerSet,240mm,Black
030.100 PushFitDisconnectionTool
111.071 TransferTubeSetfor4FFlexible(1-9)
111.081 TransferTubeSetfor4FFlexible(10-18)
OncoSmart Upgrade Set for microSelectron, part #103.110Part Number Description
189.410 CT/MROncoSmartCatheterSystem
189.036 CT/MROncoSmartCatheterSystem
030.100 PushFitDisconnectionTool
111.071 TransferTubeSetfor4F,Flexibles(1-9)
111.081 TransferTubeSetfor4F,Flexibles(10-18)
CT/MR OncoSmart Catheter SetsPart Number Description
189.416CT/MROncoSmartCatheterSet,L=240mm(contains30Flexibleimplanttubes,4FProguideneedles(240mm),stoptags,buttons,andinsertionneedles(200mm))
189.418CT/MROncoSmartCatheterSet,L=240mm(contains18Flexibleimplanttubes,4FProguideneedles(240mm),stoptags,buttons,andinsertionneedles(200mm))
189.802CT/MROncoSmartCatheterSet,L=240mm,singlepackage(contains6Flexibleimplanttubes,4FProguideneedles(240mm),stoptags,buttons,andinsertionneedles(200mm))
189.801CT/MROncoSmartCatheterSet,L=200mm,forHead&Neck(contains6Flexibleimplanttubes,4FProguideneedles(200mm),stoptags,buttons,andinsertionneedles(160mm))
189.840CT/MROncoSmartCatheterSet,L=294mm(contains30Flexibleimplanttubes,4FProguideneedles(294mm),stoptags,buttons,andinsertionneedles(280mm))
189.846CT/MROncoSmartCatheterSet,L=294mm(contains30Flexibleimplanttubes,4FProguideneedles(294mm),stoptags,buttons,andinsertionneedles(200mm))
TheOncoSmartCatheterSystemisatreatmentsolutiondesignedforbreastirradiationinAPBISettings.Itcreatestheopportunityfortreatingpatientsonanoutpatientbasiswithminimumdiscomfortforthepatient.Treatmentcathetersareinsertedduringtheactualtreatmentonly.Betweenfractions,thetreatmentcathetersareremovedandonlyasetofflexibleguidingcathetersremainsinplacewithsmallbuttonstolocktheminthetreatmentarea.Thesebuttonsarepre-numberedforquick,accurateandeasySetupateverytreatmentfraction.Thetwo-partcatheterdesignreducestheriskofcatheterskinkingduringinsertionorbetweenfractions.
OncoSmartCatheterSetscanbeusedforothertreatmentsaswell,forexampleheadandnecktumorsandsarcoma’s.OncoSmartCatheterSetsareavailableforusewithCTandMRimagingmodalities.Thesetscontainradio-lucentbuttonsforoptimalvisualization.* Please note that the insertion needles are not MR safe.
MR safe*
68 69
Prostate Martinez Prostate Template Set 70
Prostate Stepper Template Set 72
Rectum MUPIT Applicator Set 74
Intracavitary Mold Applicator Set 76
Alternatives for rectal brachytherapy Section Prostate Stepper Template Set Prostate, Rectum & Bladder 72
Vaginal CT/MR Applicator Set Gynecology 32
Shielded Cylindrical Applicator Set Gynecology 36
Alternatives for bladder brachytherapy Lumencath Applicator Set Bronchus & Esophagus 52
Prostate, Rectum & Bladder
70 71
Martinez Prostate Template Set
• Smallultralighttemplate• Individualneedlelocksforvariousneedlesizes• Noreadjustmentsafterinsertion• Quickimplantremoval• Canbeusedwithastepperorfreehandtechnique• Notoolsneededfordisassembly
Order Information
AccessoriesPart Number Description
137.286 LockInsertsSetfor5FPlasticNeedles
137.287* LockInsertsSetfor6FPlasticNeedles
137.288 LockInsertsSetfor7FPlasticNeedles
137.289 LockInsertsSetfor1.5mmMetalNeedles
137.282 TemplateHolderforRTPstepper
137.283 TemplateHolderforAccuseedstepper
137.284 TemplateHolderforD&K&CivcoclassicAccucarestepper
various** ProGuideNeedles5F
various** ProGuideNeedles6F
various** Ø1,5mmneedles
various** Ø1.9mmneedles*6FinsertscanalsobeusedforØ1.9mmmetalneedles.**SeesectionNeedles&FlexibleImplantTubes.
Complete Set, part # 137.280Part Number Description
137.281
ProstateTemplateconsistingof:TemplateholderforRTPstepperTemplatefixationpins(2pcs)Lockinsertsfor5Fplasticneedles(pouchof20pcs)(black)
137.290 NeedleLockTool
137.285 TemplateFixationPinsSet
• TheTemplateSetcanbesterilizedusingsteamsterilization.• Usermanual777.00117.
TheMartinezBrachytherapyProstateTemplateforPDR&HDRBrachytherapyhasbeendesignedtoassistinenhancingprecision.Theultralighttemplatelockstothestepperorstabilizerduringinsertionandguidesneedlesunderultrasoundimaging.Theneedlescanbeindividuallyre-positionedandlockedfortreatment.Theindividuallockinginsertensuresthatthepositionofeachneedlewillremainunchangedwhenadjustinganotherneedle.
72 73
• Holderandgridfaceplatesneedtobeorderedseparately.• ThetemplatepartscanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.699.
Prostate Stepper Template Set
• Universalgridarrayforguidanceofneedles• Allneedleslockedinasinglemovement• Lightweighttemplate• Compatiblewithawiderangeofstepperdevices
Applicable body sites:
• Prostate• Vagina• Perineum•Rectum
Order Information
Complete Clinical Set 5F, part # 189.069Quantity Part Number Description
1 189.066 ProstateStepperTemplate,5F
2 189.604 OncoSmartProGuideSharpNeedleSet,5Fx240mm
Fixation PlatesPart Number Description
189.164 Setof10disposableFixationPlates,5F(5x2)
Complete clinical Set 6F, part # 189.070Quantity Part Number Description
1 189.067 ProstateStepperTemplate,6F
2 189.602 OncoSmartProGuideSharpNeedleSet,6Fx200mm
Fixation PlatesPart Number Description
189.164 Setof10disposableFixationPlates,6F(5x2)
Prostate Stepper Template Set, 5F part # 189.066Quantity Part Number Description
1 189.157 BasePlateStepper5F
1 189.160 FrontPlateStepper5F
1 189.166 FixationPlateSupportAssy
1 189.164 DisposableFixationPlates5F,10pieces
1 189.167 EccentricAxle
2 189.170 AssemblyBoltTemplate
1 189.205 AssemblyScrewdriver
1 189.173 FixationScrewdriver
1 189.041 CleaningBrushSetø3x100mm
1 189.043 CleaningBrushSetø6.5x100mm
Stepper HoldersPart Number Description
189.071 StepperHolderSet,Tayman
189.083 StepperHolderAssembly,Tayman44.5mm
189.075 StepperHolderAssembly,Tayman73.4mm
189.072 StepperHolderSet,OncoSelect
189.076 StepperHolderAssembly,OncoSelect
189.092 StepperHolderSet,B-K
189.095 StepperHolderAssembly,B&K
189.093 StepperHolderSet,Barzell-Whitmore
189.096 StepperHolderAssembly,BW-MB
Prostate Stepper Template Set, 6F part # 189.067Quantity Part Number Description
1 189.158 BasePlateStepper6F
1 189.161 FrontPlateStepper6F
1 189.166 FixationPlateSupportAssy
1 189.165 DisposableFixationPlates6F(10pcs)
1 189.167 EccentricAxle
2 189.170 AssemblyBoltTemplate
1 189.205 AssemblyScrewdriver
1 189.173 FixationScrewdriver
1 189.041 CleaningBrushSetø3x100mm
1 189.043 CleaningBrushSetø6.5x100mm
Grid Face PlatesPart Number Description
189.073 GridFacePlateSet,GE/Siemens
189.174 GridFacePlate,GE/Siemens
189.206 GridL-frameforGE/Siemens
189.074 GridFacePlateSet,B&K
189.175 GridFacePlate,B&K
189.207 GridL-frame,B&KTheProstateStepperTemplateSetprovidesahelpfulsolutionforapplyinginterstitialtechniquesinhighdoserateprostatetreatments.Thesquarelightweightsteppertemplatehasauniversalgridarrayandcanbesuturedtothepatient.Itisplacedinastepperholderandthemountedontoastepperdevice.Thestepperholderisavailableforvariousultrasoundstepperdevices.Toplacetheneedlesinthedesiredposition,gridfaceplatesmatchingtheultrasoundimagegridaremountedonthestepperholder.Theadvancedneedlefixationdesignusesaplatethatlocksallneedlesinasingleaction.TheProstateStepperTemplatecanbeusedwitheithermetalneedlesorthehigh-performanceProGuideplasticneedles.
74 75
• Onlymetalneedles(Ø1.5or1.9mm)canbeusedwiththesesets.ProGuideneedlescannotbeused.• TheapplicatorcanbesterilizedusingsteamsterilizationorEtO.• Usermanual090.629.
MUPIT Applicator Set
• Easytousetemplateforavarietyofbodysitetreatments• Needleplacementprovidesdoseoptimizationtotheareaofinterest
Applicable body sites:
• Perineum• Rectum• Vagina
Order Information
Complete Set Ø 1.5 mm, part # 089.055
Complete Set Ø 1.9 mm, part # 083.570
Complete Sets consist of:
QuantityØ 1.5 mm Set
Part Number
Ø 1.9 mm Set
Part NumberDescription
1* 089.056 083.571 MUPITTemplateSubSet
35* 083.918 083.054 TrocarNeedle120mm
35* 083.922 083.058 TrocarNeedle160mm
35* 083.926 083.062 TrocarNeedle200mm
3* 089.005 083.254 Obturator120mm
3* 089.009 083.258 Obturator160mm
3* 089.013 083.262 Obturator200mm*Whenorderedseparately,theminimumorderquantityis10pieces.
Template Set Ø 1.5 mm, part # 089.056
Template Set Ø 1.9 mm, part # 083.571
Template SubSets consist of:
QuantityØ 1.5 mm Set
Part Number
Ø 1.9 mm Set
Part NumberDescription
1 045.459 083.590 BasePlate,small
1 045.457 083.588 BasePlatefiller,12mmhole
2 045.450 CoverPlatefiller,needles
1 045.449 CoverPlatefiller,8mmhole
1 045.460 083.586 RectalCylinder
2* 505.157 Screwforbaseplate
1 045.458 083.589 BasePlate,large
3 045.456 083.587 BasePlatefiller,Needles
1 045.443 CoverPlate
1 045.448 CoverPlatefiller,12mmhole
1 045.461 083.581 VaginalCylinder
3 045.171 083.289 CylinderAdapter,Needle
14 045.172 FixingScrew,CoverPlate
2* 505.154 ScrewforCylinder
2* 518.307 Screwfor045.449
1 598.026 AllenKeyScrewdriver,2.5mm
1 045.004 TorqueScrewdriver,1.27mm
35* 089.025 045.303 NeedleStopper
2 045.455 FixingScrew,for045.449*Whenorderedseparatelytheminimumorderquantityis10pieces.
TheMartinezUniversalPerinealInterstitialTemplate(MUPIT)isdesignedforinterstitialplacementofneedles(1.5mmor1.9mm)totreatcancerintheperineum,rectumorvagina.Theperipheryofthetemplatehasangledholesfortheneedlestoreachthewidesttumorspread.Rectalandvaginalcylindersareincludedtoprovidebettertemplatestabilityandadditionaltreatmentoptions.
76 77
• TheIntracavitaryMoldsaresingle-packedandforsingleuseonly.• Kinkprotectionsetsarepackedseparately,including5setsperbox.• Thereusablepartsofthisapplicatorcanbesterilizedusingsteamsterilization(at134°C/273°F).• Usermanual090.705.* Regulatoryapprovalpending.
Intracavitary Mold Applicator Set
• Fordown-sizinganddown-stagingoftumor
Applicable body sites:
• Rectum
Order Information for microSelectron
Order Information for Flexitron
Intracavitary Mold Applicator Set, part # 189.011Part Number Description
189.094 IntracavitaryMoldSet,ø20mm(boxof5)
189.099 SupportBlock
189.256 Number Tag Ring
189.264 InsertionTool,d=4mm
189.257 InsertionTool,d=8mm
189.277 InsertionTool,d=10mm
089.786 Screwdriver
189.040 CleaningBrushø2.5mmx250(Setof3)
189.043 CleaningBrushø6.5mmx100(Setof3)
Intracavitary Mold Applicator Set Ft, part # 110.224*
AccessoriesPart Number Description
189.094 IntracavitaryMoldSet,Ø20mm(boxof5)
189.538 KinkProtectionSet(boxof5)
189.100 CentralCatheterSet(boxof5)
189.932 ApplicatorClampandBasePlate
189.931 ApplicatorClampwithAxle
TheIntracavitaryMoldapplicatorisaninnovativesolutioninthemanagementofrectalcancers.TheIntracavitaryMoldisusedpre-operativelyintreatmentregimensaimedatreducingthetumorsize,eitherasthesolemodalityindeliveringthedesireddose,orasaboostalongsideEBRT.TheflexibilityoftheIntracavitaryMoldapplicatorassistsinadjustingtotherectalcurvature,andensurespatientcomfort.Theeightradiallydistributedtreatmentcathetersjustbelowthesurfaceofthecylinderensureperfectcoverageofthetargetvolumewhilesparingadjacenthealthytissue.TheIntracavitaryMoldapplicatorhasbeendevelopedincollaborationwithDr.T.VuongoftheMcGillUniversityHealthCenterinMontreal,Canada,insupportoftheirneoadjuvanttreatmentforpatientswithresectablerectalcancer[1],[2].[1]VuongT,etal,HighDoseRateEndorectalBrachytherapyasaNeoadjuvantTreatmentforPatientswithResectableRectalCancer.ClinOncol2007;19:701-705.
[2]Poonetal.Dosimetriccharacterizationofanovelintracavitarymoldapplicatorfor192Irhighdoserateendorectalbrachytherapytreatment.Med.Phys.2006;33:4515-4526.
78 79
Skin & Surface
Rigid Applicators Valencia Skin Applicator 80
Leipzig Applicator 82
Flexible Applicator Freiburg Flap Applicator Set 84
80 81
• Applicatorprovidedwithtwotypesoftreatmentcaps,forsimulationandfortreatment.• Applicatormustbeusedwithtreatmentcapinplace.• TheapplicatorsetcanbesterilizedusingsteamsterilizationandEtO.• Usermanual777.00237.
Order Information for microSelectron
Valencia Skin Applicator Set, part # 189.701Quantity Part Number Description
1 189.788 ValenciaSkinApplicator,d=20mm
1 189.760 ValenciaSkinApplicator,d=30mm
2 085.115 Capwithmarkerring,d=20mm
2 085.116 Capwithmarkerring,d=30mm
2 085.118 Cap,d=20mm
2 085.119 Cap,d=30mm
1 084.158 SterilizationCaps(packof50)
AccessoriesPart Number Description
189.786*WellChamberAdapterforHDR1000PLUS(StandardImaging,Middleton,Wisconsin)
189.787*WellChamberAdapterforTM33004(PTW,FreiburgGermany)
189.932 CT/MRApplicatorClampwithBaseplate
189.931 CT/MRApplicatorClampwithAxle* Required for use
Valencia Skin Applicator
• Non-invasivetreatmentmodality• Homogeneousandreproducibledosecoveragesuitableforbiggerskinlesions• Reliabletreatmentthroughsecureddistalreferencepointforthesourceintheapplicator
Applicable body sites:
• Surfacetreatments
Advanced Skin Applicator Set, part # 103.118Part Number Description
085.041 LeipzigApplicatord=10mm
085.042 LeipzigApplicatord=20mm
085.043 LeipzigApplicatord=30mm
085.114 Cap,d=10mmwithmarkingring
085.115 Cap,d=20mmwithmarkingring
085.116 Cap,d=30mmwithmarkingring
085.117 Cap,d=10mm
085.118 Cap,d=20mm
085.119 Cap,d=30mm
089.095 FreiburgFlapApplicatorSet
189.701 ValenciaAplpicatorSet
ThisuniqueapplicatorisaresultofcooperationbetweentheLaFéUniversityHospital,Valencia,SpainandNucletron.ThistungstenshieldedHDRapplicatorisdesignedforsurfacelesions,utilizingacontacttreatmenttechnique.Itisequippedwithauniquefixedflatteningfilterthatwillprovideaflathomogeneousisodosepattern.Itcanbeusedforsuperficialandintra-orallesions.
82 83
• Applicatorprovidedwithdosimetryandtreatmentcaps.• Applicatormustbeusedwithtreatmentcapinplace.• ThisapplicatorisalsoavailableaspartoftheAdvancedSkinpackage#103.118.• TheapplicatorsetcanbesterilizedusingsteamsterilizationandEtO.• Usermanual777.00237.
Order Information
Leipzig Applicator Set, part # 085.040Part Number Description
085.041 LeipzigApplicator,d=10mm
085.044 LeipzigApplicatord=10mm,straight
085.114 Cap,d=10mmwithmarkerring
085.117 Cap,d=10mm
085.042 LeipzigApplicator,d=20mm
085.045 LeipzigApplicatord=20mm,straight
085.115 Cap,d=20mmwithmarkerring
085.118 Cap,d=20mm
085.043 LeipzigApplicator,d=30mm
085.046 LeipzigApplicatord=30mm,straight
085.116 Cap,d=30mmwithmarkerring
085.119 Cap,d=30mm
084.158 SterilizingCaps,3.2mm
Leipzig Applicator
• Easytouse• Perfectforsuperficiallesions
Applicable body sites:
• Skin&Surface• Intra-oraltreatment• VaginalCuff
Advanced Skin Applicator Set, part # 103.118Part Number Description
085.041 LeipzigApplicatord=10mm
085.042 LeipzigApplicatord=20mm
085.043 LeipzigApplicatord=30mm
085.114 Cap,d=10mmwithmarkingring
085.115 Cap,d=20mmwithmarkingring
085.116 Cap,d=30mmwithmarkingring
085.117 Cap,d=10mm
085.118 Cap,d=20mm
085.119 Cap,d=30mm
089.095 FreiburgFlapApplicatorSet
189.701 ValenciaAplpicatorSet
Thisapplicatoristungstenshieldedanddesignedfortreatmentofsurfacelesions,utilizingacontacttreatmenttechnique.Itcanbeusedforsuperficialskin,intra-oralandvaginalcufflesions.Itprovidesanexcellentalternativefor orthovoltage or electron treatments.
“TheLeipzigApplicatorsweredesignedtogive theoptimumisodoseandtreattothecorrectdepth withoutcausingexcessiveskinreaction.”
Prof. Dr. Prager UniversitätLeipzig,Leipzig,Germany
84 85
• Applicableforupto28days’implantation.• Treatmentchannelsareset10mmapartfromeachother,andhavealengthof240mm.• TheFlexibleImplantTubesandbuttonscomesterilizedandareforsingle-useonly.• Usermanual090.677.
Order Information
Freiburg Flap Applicator Set, part # 089.095Part Number Description
592.976 FreiburgFlap
189.445CT/MRFlexibleImplantTube6F,singleleader,30cm(6pouchesof6pcs)
189.367 Cutter,FlexibleImplantTubes
189.458 RadiolucentButton,white(72pieces)
Freiburg Flap Applicator Set
• Adaptabletoanybodysiteororgansurface• Reproducibledosimetry
Applicable body sites:
• Skin&Surface• Intra-operative
Advanced Skin Applicator Set, part # 103.118Part Number Description
085.041 LeipzigApplicatord=10mm
085.042 LeipzigApplicatord=20mm
085.043 LeipzigApplicatord=30mm
085.114 Cap,d=10mmwithmarkingring
085.115 Cap,d=20mmwithmarkingring
085.116 Cap,d=30mmwithmarkingring
085.117 Cap,d=10mm
085.118 Cap,d=20mm
085.119 Cap,d=30mm
089.095 FreiburgFlapApplicatorSet
189.701 ValenciaAplpicatorSet
MR safe*
TheFreiburgFlapisaflexiblemeshstylesurfacemoldforskinorintra-operativesurfacetreatments.Itcontains36channelsforFlexibleImplantTubes.Themoldcanbeeasilyadaptedtoanyshape.Itensuresaconstantdistanceofthetreatmentcathetertotheskinof5mm,forreproducibledosimetry.Themoldprovidesanexcellentalternativefororthovoltage or electron treatments.* Please note that the obturators are not MR safe.
“Theequidistanceoftheholesguaranteesapreciseseparationofthecatheters.TheFreiburgFlap materialallowsaprecisepositioninginrespectofthetargetandverificationofthetreatmentarea.”
Dr. S. Stange AlbertLudwigsUniversität,Freiburg,Germany
86 87
Head & Neck
Nasopharynx Standard Nasopharyngeal Applicator Set 88
Rotterdam Nasopharyngeal Mold 90
Tongue Pipard Tongue Template Set 92
Alternative for Tongue brachytherapy Section OncoSmart Catheter System Breast 66
88 89
• Theballoondoesnotcomesterilizedandisforsingleuseonly.• TheapplicatorcanbesterilizedusingsteamsterilizationorEtO(085.067onlywithEtO).• Usermanual090.630.
Order Information
Complete Set, part # 085.065Quantity Part Number Description
2 085.066 StandardNasopharyngealApplicator
5 085.067 NasopharyngealBalloon
1 084.158 SterilizingCaps,3.2mm
Standard Nasopharyngeal Applicator Set
• Designedforeasyplacementwithoutgeneralanesthetic• Balloonensuresimmobilizationandreducessurfacedose
TheStandardNasopharyngealApplicatorisdesignedfortreatmentofthenasopharyngealcavity.Itcontainsanexpandableballoonthatisinflatedafterinsertionintothenasopharyngealcavity.Thisprovidesimmobilizationoftheapplicatorandensuresoptimaldosepenetration,whilereducingthesurfacedose.Theballooniseasilyinsertedintothenasopharyngealcavitywithoutgeneralanesthetic.Itisdesignedforsingleuseandcanbeexpandedtoamaximumof30mm.
90 91
Order Information
Complete Set, part # 089.068Quantity Part Number Description
5 089.062 NasopharyngealMoldApplicator
5 089.061 NasopharyngealCatheterSet
1 089.421 X-RayCatheterno.1;30cm
1 089.422 X-RayCatheterno.2;30cm
1 594.588* K-YLubricatingGel;Tube82gr*Whenorderedseparatelytheminimumorderquantityis10pieces.
Rotterdam Nasopharyngeal Mold
• Easilyconformstoarangeofnasopharyngealcavitysizes• Dualchanneldesignforoptimizeddosedistribution• Catheterscanbeeasilyreplacedformultiplefractions
• Themoldapplicatorandcathetersetdonotcomesterilizedandareforsingleuseonly.• Theapplicatorpartscanbeprocessedusingsteamsterilization;thenasopharyngealcathetersusingEtO.• Usermanual090.678.
MR safe
TheRotterdamNasopharyngealMoldismadeofaflexiblesiliconethateasilyconformstothenasopharyngealcavity.Itconsistsoftwochannelsontheuppersurfacetooptimizethedosedistributionandreducethesurfacedose.Themoldcanremaininplaceforfractionatedtreatment,andthetreatmentcatheterscanberemovedinbetweenfractions.
“Iwantedanapplicatorthatwaseasytouse,didnotrequireageneral anestheticandthatwouldcloselyconformtothemucosaofthenasopharynx. IfounditintheRotterdamNasopharyngealApplicator.”
Prof. Dr. P. Levendag DanieldenHoedClinic,Rotterdam,theNetherlands
92 93
• TheapplicatorcanbesterilizedusingsteamsterilizationorEtO.• Usermanual090.641.
Order Information
Complete Set, part # 045.410Quantity Part Number Description
1 045.435 AdjustableTongueTemplateholder
1 045.432 TongueTemplate,8holes,1.5mm
1 045.433 TongueTemplate,10holes,1.5mm
10 089.700 LeaderInsertionNeedle,1.5x120mm
Pipard Tongue Template Set
• Reproducibledosimetry• Guidanceduringneedle/implantTubeplacement• Immobilizationduringtreatment Accessories
Part Number Description
089.701 LeaderInsertionNeedle,1.5x160mm
089.702 LeaderInsertionNeedle,1.5x200mm
various* FlexibleImplantTubes
various* OncoSmartCatheterSystem*Seerelevantpagesinthisguide.
ThePipardTongueTemplateSetisdesignedforaccurateplacementofneedlesandFlexibleImplantTubesinthebaseofthetongue.Avarietyoftemplateconfigurationsprovidestheoptionofdoseoptimizationtotheareaofinterest,whileareproducibledosimetrycanbeachieved.ThetemplatesetcanbeusedfortheloopingimplantationtechniquebyusingdoubleleaderFlexibleImplantTubes.
94 95
Bile Duct Arnhem Bile Duct Applicator 96
Alternative for Pancreas brachytherapy Section Arnhem Bile Duct Applicator Pancreas & Bile Duct 96
Alternative for Bile Duct brachytherapy Lumencath Applicator Set Bronchus & Esophagus 52
Pancreas & Bile Duct
96 97
• Theapplicatorsetconnectsdirectlytotheafterloader.Noseparatetransfertubeisrequired.• ThisapplicatorsetcanonlybeusedwithmicroSelectronafterloaders.• TheapplicatorcanbesterilizedusingEtOsterilization.• Usermanual090.638.
Order Information
Arnhem Bile Duct Applicator
• Availableindifferentlengthsandcanbeplacedwithinadrainagetube• Providedwithanextraouterlayertoreducethesurfacedose
Applicable body sites:
• Pancreas• Intralumenal
Part Number Description
085.001 ArnhemBileDuctApplicator,d=3,2mm,100cm
TheArnhemBileDuctApplicatorisintendedforthetreatmentofcarcinomaofthebileduct.Itisplaceddirectlywithin the drainage tube. It features an additional outer layer to reduce the surface dose. It is also suitable for other intra lumenal treatments.
98 99
Metal Interstitial Needles Metal Interstitial Needles 102
Plastic Interstitial Needles ProGuide Needles & Markers 100
Flexible Implant Tubes Flexible Implant Tubes 106
CT/MR Flexible Implant Tubes 106
Accessories for Flexible implants Emergency Button Cutter 107
Kink Protection Tubes 107
Push Fit Disconnection Tool 107
Needles & Flexible Implant Tubes
100 101
ProGuide Needles & Markers
• Flexibilityinuse• Compatiblewithstate-of-the-artimagingmodalities
ProGuide Needle Sets, 5F, SharpPart Number Description
189.604 ProGuideNeedleSet,5F,sharp,L=240mm,18needles(setcontains3pouchesof6needleseach,and6Obturators)
189.619 ProGuideNeedleBulkSet,5F,sharp,L=240mm,55needles(setcontains8pouchesof6needleseach,and7poucheswithsingle-packedneedles)
Obturators for ProGuide NeedlesPart Number Description
189.631 ObturatorBulkSet,forneedles5FandL=240mm,12Obturators
189.629 ObturatorBulkSet,forneedles6FandL=200mm,12Obturators
189.628 ObturatorBulkSet,forneedles6FandL=240mm,12Obturators
Order Information
ProGuide Needle Sets, 6F, SharpPart Number Description
189.602 ProGuideNeedleSet,6F,sharp,L=200mm,18needles(setcontains3pouchesof6needleseach,and6Obturators)
189.601 ProGuideNeedleSet,6F,sharp,L=240mm,18needles(setcontains3pouchesof6needleseach,and6Obturators)
110.231 ProGuideNeedleSet,6F,sharp,L=294mm,5needles(setcontains5poucheswithsingle-packedneedles)
189.617 ProGuideNeedleBulkSet,6F,sharp,L=200mm,55needles(setcontains8pouchesof6needleseach,and7poucheswithsingle-packedneedles)
189.616 ProGuideNeedleBulkSet,6F,sharp,L=240mm,55needles(setcontains8pouchesof6needleseach,and7poucheswithsingle-packedneedles)
• ProGuideneedlescomesterilized,andareforsingleuseonly.• ObturatorsmustbeplacedintheProGuideneedlepriortoinsertionforstabilityandtoavoidneedledamage. ObtuatorsdonotcomesterilizedandcanbeprocessedusingsteamsterilizationorEtO.• KinkprotectiontubesareavailableforusewithProGuideneedles.• Usermanual090.695.
ProGuide Needle Sets, 6F, RoundPart Number Description
189.608 ProGuideNeedleSet,6F,round,L=200mm,18needles(setcontains3pouchesof6needleseach,and6Obturators)
189.607 ProGuideNeedleSet,6F,round,L=240mm,18needles(setcontains3pouchesof6needleseach,and6Obturators)
110.230 ProGuideNeedleSet,6F,round,L=294mm,5needles(setcontains5poucheswithsingle-packedneedles)
189.623 ProGuideNeedleBulkSet,6F,round,L=200mm,55needles(setcontains8pouchesof6needleseach,and7poucheswithsingle-packedneedles)
189.622 ProGuideNeedleBulkSet,6F,round,L=240mm,55needles(setcontains8pouchesof6needleseach,and7poucheswithsingle-packedneedles)
OncoSmart ProGuide CT-Marker Sets (channel 1-18)Part Number Description
189.034 CT-MarkerSet200mm,Metal
189.036 CT-MarkerSet240mm,Black
189.039 CT-MarkerSet294mm,Yellow
OncoSmart ProGuide CT-Marker Sets (channel 19-30)Part Number Description
189.691 CT-MarkerSet200mm,Metal
189.692 CT-MarkerSet240mm,Black
189.693 CT-MarkerSet294mm,Yellow
OncoSmart ProGuide CT-Marker Sets (channel 1-6)Part Number Description
110.285 CT-MarkerSet200,Metal
110.286 CT-MarkerSet240,Black
110.287 CT-MarkerSet294,Yellow
MR safe*
TherangeofOncoSmartProGuideneedleshasbeendesignedforinterstitialapplicationsincombinationwithimage-basedplanningprotocolsusingforinstanceCTandMRimaging.Theyaremadefromahigh-qualityplasticandarespecificallydevelopedforusewithNucletronafterloaders.ProGuideneedlesareavailablewitheitherasharptiptoenableeasypenetrationoftheskinsurface,orwitharoundtipformaximumpatientsafetyduringtreatment.RigidityoftheplasticProGuideneedleiscreatedbyplacinganobturatorinsidetheneedleduringinsertion.ProGuideneedlescomesterilized,tosimplifytheworkflowintheclinic.
TheOncoSmartProGuideCT-MarkersaredesignedtoindicatethefirstsourcepositionsonCT-imagesofProGuideinterstitialneedleimplants.Themarkersfitneedlediametersfrom4Fto6Fandarekeptinplaceduringimagingbymeansofabuilt-inlockingmechanism.Themarkersarereusableandcanbeautoclaved.Eachmarkerlengthhasauniquecolor-codedknob.* Please note that the obturators are not MR safe.
102 103
Metal Interstitial Needles
• Designedforoptimalneedlerigidityandsharpnessduringinterstitialtreatments• Needletipavailableinvariousgeometriestoadapttoclinicalneeds
• Needlesaredescribedbytheiroutsidediameterandlength.• Needlesshouldbeinspectedpriortouse.Anyneedlethatisblunt,corrodedorbentshouldnotbeused.• MetalneedlescanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.719.
Order Information Titanium Needle Sets
Trocar Point Needles Part Number Description
110.020TrocarPointTitaniumNeedleSet,1.9mmx200mm(Setof5needles)
110.021TrocarPointTitaniumNeedleSet,1.9mmx240mm(Setof5needles)
AccessoriesPart Number Description
083.252 Obturator,l=100mm*
089.636 HandleforObturator
189.996 TitaniumNeedleStopperSet
045.004 TorqueScrewdriverforNeedleStopper
083.147 SterilizingCaps,1.9mm(50pieces)*Minimumorderquantityis10pieces.
Round Point Needles Part Number Description
110.022RoundPointTitaniumNeedleSet,1.9mmx200mm(Setof5needles)
110.023RoundPointTitaniumNeedleSet,1.9mmx240mm(Setof5needles)
Bevel point Trocar point
Interstitialneedlesareusedfortreatmentofcarcinomawherenolumenorcavityisavailable,orwhereadditionalandveryprecisetargetareacoverageisrequired.Thesemetalneedlesaredesignedtomaintaintheirrigidityandsharpnessthroughoutmultipletreatments,incombinationwiththeappropriateNucletrontemplates.Interstitialneedlesareavailableinstainlesssteelortitanium,withaneedletipthatiseitherround,bevelortrocarshaped.Theroundtipisdesignedtominimizetissuedamageandoptimizeeaseinimplantation.Thetrocarandbeveltipfacilitateinsertioninthetissue.Obturatorscanbeplacedinsidetheneedleduringinsertiontocreateadditionalrigidity.InterstitialneedlesaredirectlyconnectedtothetransfertubeoftheNucletronafterloader.TheirmaterialmakestheInterstitial needles ideal for use in combination with image guidance of the treatment. The titanium interstitial needles arespecificallydesignedforusewithCTandMR-basedimagingforvolumeandtargetdelineation,designedtominimizeartifactsontheacquiredimagesets.
104 105
• Needlesaredescribedbytheiroutsidediameterandlength.• ø1.3mmneedlescanonlybeusedwithmicroSelectron.• Needlesshouldbeinspectedpriortouse.Anyneedlethatisblunt,corrodedorbentshouldbediscarded.• MetalneedlescanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.619.
Order Information Stainless Steel Needle Sets
AccessoriesPart Number Description
083.147 SterilizingCaps,1.9mm(50pcs)*Whenorderedseparatelytheminimumorderquantityis100pieces.
Interstitial Needle Basic Set 1.5 mm, part # 083.900Quantity Part Number Description
20* 083.914 TrocarNeedle1.5mmx80mm
20* 083.916 TrocarNeedle1.5mmx100mm
20* 083.918 TrocarNeedle1.5mmx120mm
20* 083.920 TrocarNeedle,1.5mmx140mm
20* 083.922 TrocarNeedle1.5mmx160mm
20* 083.924 TrocarNeedle1.5mmx180mm
20* 083.926 TrocarNeedle,1.5mmx200mm
20* 089.001 Obturatorfor1.5mmNeedlex80mm
20* 089.003 Obturatorfor1.5mmNeedlex100mm
20* 089.005 Obturatorfor1.5mmNeedlex120mm
20* 089.007 Obturatorfor1.5mmNeedlex140mm
20* 089.009 Obturatorfor1.5mmNeedlex160mm
20* 089.011 Obturatorfor1.5mmNeedlex180mm
20* 089.013 Obturatorfor1.5mmNeedlex200mm
1 045.004 TorqueScrewdriver,1.27mm
40* 089.025 Needlestopper1.5mm
1 083.905 SterilizationBox*Whenorderedseparatelytheminimumorderquantityis10pieces.
Interstitial Needle Basic Set 1.9 mm, part # 083.040Quantity Part Number Description
20* 083.050 TrocarNeedle,1.9mmx80mm
20* 083.052 TrocarNeedle,1.9mmx100mm
20* 083.054 TrocarNeedle,1.9mmx120mm
20* 083.056 TrocarNeedle,1.9mmx140mm
20* 083.058 TrocarNeedle,1.9mmx160mm
20* 083.060 TrocarNeedle,1.9mmx180mm
20* 083.062 TrocarNeedle,1.9mmx200mm
20* 083.250 Obturatorfor1.9mmNeedlex80mm
20* 083.252 Obturatorfor1.9mmNeedlex100mm
20* 083.254 Obturatorfor1.9mmNeedlex120mm
20* 083.256 Obturatorfor1.9mmNeedlex140mm
20* 083.258 Obturatorfor1.9mmNeedlex160mm
20* 083.260 Obturatorfor1.9mmNeedlex180mm
20* 083.262 Obturatorfor1.9mmNeedlex200mm
40* 083.001 StainlessSteelStopper,1.9mmNeedle
1 045.004 TorqueScrewdriver,1.27mm
1 594.127 LidforSterilizationBox
1 083.447 SterilizationBox*Whenorderedseparatelytheminimumorderquantityis10pieces.
Order Information Stainless Steel Needle Sets, Trocar or Bevel Point
Trocar Point Needle Set, 1.3 mm øQuantity Part Number Description
10* 110.109 TrocarNeedle,1.3mmx120mm
10* 110.113 TrocarNeedle,1.3mmx160mm
10* 110.117 TrocarNeedle,1.3mmx200mm*Whenorderedseparatelytheminimumorderquantityis10pieces.
AccessoriesPart Number Description
083.147 SterilizingCaps,1.9mm(50pieces)
Trocar Point Needle Set, 1.9 mm øQuantity Part Number Description
10* 083.050 TrocarNeedle,1.9mmx80mm
10* 083.052 TrocarNeedle,1.9mmx100mm
10* 083.054 TrocarNeedle,1.9mmx120mm
10* 083.056 TrocarNeedle,1.9mmx140mm
10* 083.058 TrocarNeedle,1.9mmx160mm
10* 083.060 TrocarNeedle,1.9mmx180mm
10* 083.062 TrocarNeedle,1.9mmx200mm
10* 083.066 TrocarNeedle,1.9mmx240mm
10* 083.072 TrocarNeedle,1.9mmx294mm*Whenorderedseparatelytheminimumorderquantityis10pieces.
Trocar Point Needle Set, 1.5 mm øQuantity Part Number Description
10* 083.914 TrocarNeedle,1.5mmx80mm
10* 083.916 TrocarNeedle,1.5mmx100mm
10* 083.918 TrocarNeedle,1.5mmx120mm
10* 083.920 TrocarNeedle,1.5mmx140mm
10* 083.922 TrocarNeedle,1.5mmx160mm
10* 083.924 TrocarNeedle,1.5mmx180mm
10* 083.926 TrocarNeedle,1.5mmx200mm*Whenorderedseparatelytheminimumorderquantityis10pieces.
• Needlesaredescribedbytheiroutsidediameterandlength.• Needlesshouldbeinspectedpriortouse.Anyneedlethatisblunted,corroded,orbentshouldbediscarded.• MetalneedlescanbesterilizedusingsteamsterilizationandEtO.• Usermanual090.619.
Bevel Point Needles, 1.9 mm øPart Number Description
083.045* BevelNeedle,1.9mmx200mm*Whenorderedseparatelytheminimumorderquantityis20pieces.
106 107
Flexible Implant Tubes
TheOncoSmartFlexibleImplantTubesaredevelopedfortreatmentsthatrequireamoldablesourcepath.TheFlexibleImplantTubesareequippedwith`leaders’toruntheimplanttubethroughachannelinthetissuethatispreformedbyaleaderinsertionneedle.TheFlexibleImplantTubesareavailableinvariousconfigurations:singleleaderwithbuttonend;singleleaderwithblindend,ordoubleleader.Theycomesterilizedandreadyforimmediateclinicaluse.ToimprovevisibilityoftheFlexibleImplantTubesincombinationwithstateoftheartCTandMRimagingmodalities,dedicatedCT/MRFlexibleImplantSetsand buttons are available.
AccessoriesPart Number Description
189.445 CT/MRFlexibleImplantTube,6F,Singleleader,30cm(boxof36)
189.504** FlexibleImplantTube,6F,Singleleader,50cm(boxof36)
189.502 FlexibleImplantTube,6F,Doubleleader,50cm(boxof36)
189.500 FlexibleImplantTube,6F,Blindend,50cm(boxof36)
189.510** FlexibleImplantTube,5F,Singleleader,30cm(boxof36)
189.508 FlexibleImplantTube,5F,Doubleleader,30cm(boxof36)
189.506 FlexibleImplantTube,5F,Blindend,30cm(boxof36)
189.292** Radio-opaqueButtonyellow,6F(boxof72)
189.294** Radio-opaqueButtonbrown,6F(boxof72)
189.472** Radio-opaqueButtonwhite,5F(boxof72)
189.474** Radio-opaqueButtonblack,5F(boxof72)
189.476** Radio-opaqueButtonred,5F(boxof72)
189.478** Radio-opaqueButtonblue,5F(boxof72)
189.480** Radio-opaqueButtongreen,5F(boxof72)
189.482** Radio-opaqueButtonyellow,5F(boxof72)
189.484** Radio-opaqueButtonbrown,5F(boxof72)
045.103 S.s.Button,Henschke
045.046 BevelNeedle,OpenEnd,1.5x200mm
089.021 CatheterInsertionSet,6FTrocar
089.023 CatheterInsertionSet,6FBevel
594.456 EmergencyButtonCutter
089.420 X-RayCatheterSet,30cm(1-18)
030.100 PushFitDisconnectionTool
089.348 KinkProtectionTube,for6FFlexible*
089.345 KinkProtectionTube,forTransferTube**Minimumorderquantityis50pieces.**ButtonisnotCT/MRcompatible.
Flexible Implant Tube Set, 6F, 30 cm, part # 189.400*Quantity Part Number Description
2 189.300FlexibleImplantTube,6F,Singleleader,30cm(boxof36)
2 189.298FlexibleImplantTube,6F,Doubleleader,30cm(boxof36)
2 189.296FlexibleImplantTube,6F,Blindend,30cm(boxof36)
1 189.282 Radio-opaqueButtonwhite,6F(boxof72)
1 189.284 Radio-opaqueButtonblack,6F(boxof72)
1 189.286 Radio-opaqueButtonred,6F(boxof72)
1 189.288 Radio-opaqueButtonblue,6F(boxof72)
1 189.290 Radio-opaqueButtongreen,6F(boxof72)
1 189.367 CutterFlexibleImplants
1 189.437LeaderInsertionneedles,1.5x200mm,72needles(boxof72)
*Setcontainsnon-CT/MRcompatibleparts.
• FlexibleImplantTubescomesterilized,andareforsingleuseonly.• FlexibleImplantTubesarepackedinpouchesof6,andwith6pouchesperbox.• Buttonsarepackedinpouchesof6,andwith12pouchesperbox.• ForFlexitronafterloaders,onlyFlexibleImplantTubeswithlength≤400mmcanbeused.• Usermanual090.710.* Please note that the insertion needles are not MR safe.
CT/MR Flexible Implant Tube Set, 6F, 30 cm, part # 189.401Quantity Part Number Description
2 189.445CT/MRFlexibleImplantTube,6F,Singleleader,30cm(boxof36)
2 189.298FlexibleImplantTube,6F,Doubleleader,30cm(boxof36)
2 189.296FlexibleImplantTube,6F,Blindend,30cm(boxof36)
1 189.458 Radiolucentbuttonwhite,6F(boxof72)
1 189.460 Radiolucentbuttonblack,6F(boxof72)
1 189.462 Radiolucentbuttonred,6F(boxof72)
1 189.464 Radiolucentbuttonblue,6F(boxof72)
1 189.466 Radiolucentbuttongreen,6F(boxof72)
1 189.367 CutterFlexibleImplants
1 189.437 Leaderinsertionneedle,1.5x200mm
Emergency Button Cutter
EmergencyButtonCutterisdesignedtoeasilycutthroughthebuttonofaFlexibleImplantTubeinordertoremovethecatheterintactfromtheimplantsite.
Accessories for Flexible Implants
Emergency Button CutterPart Number Description
594.456 EmergencyButtonCutter
Kink Protection Tubes
TheKinkProtectionTubesaredesignedtofitovertheTransferTube,ProGuideneedle,orFlexibleImplantTubeand button during and in between treatment fractions to reducetheriskofkinking.
Kink Protection TubesPart Number Description
089.345* KinkprotectionTube,fortransferTube
089.347* KinkprotectionTube,5F
089.348* KinkprotectionTube,6F*Minimumorderquantityis50pieces.
Push Fit Disconnection ToolPart Number Description
030.100* PushFitDisconnectionToolformicroSelectron
137.099 TransferTubeUnlockToolforFlexitron*Showninpicture.
Push Fit Disconnection Tool
ThePushFitDisconnectionToolcanbeusedforquickandeasydisconnectionofImplantTubesorneedlesfromthe Transfer Tubes.
MR safe*
108 109
Source Position Check Ruler 110
Source Position Simulator 110
CT/MR Applicator Clamp 111
Patient Belt Coupling (PBC) 112
Quality Assurance & Accessories
110 111
• ItisrecommendedtostoreGAFCHROMIC®filminthedarkuntiluse.
Order Information
For microSelectron Part Number Description
096.035SourcePositionCheckRuler(including2GAFCHROMIC®filmstrips)
For Flexitron Part Number Description
136.196 3-ChannelSourcePositionCheckRuler
Part Number Description
111.094* Source Position Simulator **ForusewithmicroSelectrononly
AccessoriesPart Number Description
096.271A10 GAFCHROMIC®filmstrip(boxof10)
Source Position Check Ruler
TheSourcePositionCheckRulerisdesignedforverificationofthecorrecttreatmentpositionofthesourcesandcheckcable,andofthelengthofeachofthetransfertubes.ItcanbeusedwitheitherthemechanicalindicatororGAFCHROMIC®filmstrip,amethodthatenablesinstantloggingoftheresultofthemeasurement.
TheSourcePositionCheckRulerhasembeddedmarkersthatallowmultiplemeasurementsandserveasreferencetovalidatecorrectpositioningoftheGAFCHROMIC®filmstrip.Thefilmsaretransparentforeasydigitizingorscanning,andareself-developing.
Quality Assurance for Source Positioning CT/MR Applicator Clamp
Source Position Simulator
The Source Position Simulator is designed to determine thedistalreferencelengthofanapplicator,andtodeterminethetreatmentareaunderfluoroscopy.
• ThebaseplateisX-Raytranslucent.• Allclampcomponentscanbesterilizedusingsteamsterilization.
CT/MR Applicator Clamp with base plate, # 189.932Quantity Part Number Description
1 189.933 FixationPart
1 189.934 Baseplate
4 189.968 InsertsØ3mm(titaniumcoloured)
4 189.950 InsertsØ6mm(whitecoloured)
4 189.969 InsertsØ12mm(blackcoloured)
AccessoriesPart Number Description
189.981 Setof4insertsØ3mm(titaniumcolored)
189.980 Setof4insertsØ6mm(whitecolored)
189.982 Setof4insertsØ12mm(blackcolored)
189.952 SpareApplicatorFixationKnob(small)
189.959 SpareClampFixationKnob(large)
CT/MR Applicator Clamp with Axle, # 189.931Quantity Part Number Description
1 189.933 FixationPart
1 189.935 Axle
4 189.968 InsertsØ3mm(titaniumcoloured)
4 189.950 InsertsØ6mm(whitecoloured)
4 189.969 InsertsØ12mm(blackcoloured)
• Canbeusedwithvariousimagingmodalities• Accurateapplicatorfixation• Easytouse
TheCT/MRApplicatorClampisdesignedforfixationofapplicatorstoapatienttreatmenttableorpatientbed.ItiscompatiblewithuseofCTandMRimaging.Withoneknoballvariablessuchaslength,rotation,slopingandangleoftheinsertedapplicatorcanbefixed.Forfixationoftheapplicatoritself,variousinsertsareprovidedthatallowfittingallavailableNucletronapplicatorswithintheclamp.Theentireassemblyrequiresnooil,andcaneasilybetakenapartforcleaningpurposes.TheCT/MRApplicatorClampcanbeattachedtoabaseplateforimmobilizationinanyhospitalbedortheclampcanbemountedonanaxleinordertoattachtheclamptoforexampleahospitalbedIBUtableetc.
MR conditional
112 113
Coupling Transfer Tube Sets Part Number Description
111.420 CouplingTransferTubeSet(channel1-18)
111.520 CouplingTransferTubeSet(channel19-30)
111.440 CouplingTransferTubeSetforNeedles(channel1-18)
111.535 CouplingTransferTubeSetforNeedles(channel19-30)
111.500CouplingTransferTubeSetfor4FFlexibleImplantTubes(channel1-18)
111.580CouplingTransferTubeSetfor4FFlexibleImplantTubes(channel19-30)
111.460CouplingTransferTubeSetfor5FFlexibleImplantTubes(channel1-18)
111.550CouplingTransferTubeSetfor5FFlexibleImplantTubes(channel19-30)
111.480CouplingTransferTubeSetfor6FFlexibleImplantTubes(channel1-18)
Accessories for PBC SetsPart Number Description
030.100 PushFitDisconnectiontool*
111.381 GYNPBCtransferTubekeyedforchannel1
111.382 GYNPBCtransferTubekeyedforchannel2
111.383 GYNPBCtransferTubekeyedforchannel3
111.384 GYNPBCtransferTubekeyedforchannel4
079.087 QuickreleasecouplingSet*forusewithFlexibleImplantTubesonly.
PBC Set for Needles and Flexibles, part # 111.379 Part Number Description
030.299 PatientWaistBeltSet
111.440 CouplingTransferTubeSetforNeedles(1-18)
111.480 CouplingTransferTubeSet6FFlexibles(1-18)
079.087 QuickReleaseCouplingSet
111.420 CouplingTransferTubeSet
PBC Set for Gynecologic Applicators, part # 111.380 Part Number Description
032.345 PatientLegBeltSet
111.421 CouplingTransferTubeno.1
111.422 CouplingTransferTubeno.2
111.423 CouplingTransferTubeno.3
079.087 QuickReleaseCouplingSet
111.381 Gyn.TransferTube,ch1
111.382 Gyn.TransferTube,ch2
111.383 Gyn.TransferTube,ch3
PBC Set for Flexible Implant Tubes, part # 111.385 Quantity Part Number Description
1 030.299 PatientWaistBeltSet
1 111.480 CouplingTransferTubeSet6FFlexibles(1-18)
1 079.087 QuickReleaseCouplingSet
1 111.420 CouplingTransferTubeSet
PBC Set for Interstitial Needles, part # 111.386 Part Number Description
030.299 PatientWaistBeltSet
111.440 CouplingTransferTubeSetforNeedles(1-18)
079.087 QuickReleaseCouplingSet
111.420 CouplingTransferTubeSet
PatientBeltCouplingSets,featuringtheQuickReleaseCouplingdevice,aredesignedtosupportauser-friendlyfixationoftransfertubesandapplicatorcomponents.TheQuickReleaseCouplingenablesapatienttobeconnectedanddisconnectedfromtheafterloaderinaquickandeasyway.DedicatedtransfertubesareconnectedtoseparatepartsoftheQuickReleaseCouplingandsimilarlytothepatientandtheafterloader.ThepatientconnectorpartoftheQuickReleaseCouplingisfixedinpositionusingapatientbelt.Withalltransfertubesinplaceonthepatientandontheafterloaderside,theseparatepartsoftheQuickReleaseCouplingareconnectedordisconnectedbyaonesimpletwist.CompletePatientBeltCouplingSetsforvarioustypesofapplicatorsareavailable.
Patient Belt Coupling (PBC)*
* AvailableonlyforusewithmicroSelectronafterloader.
114 115
A Accessories 108
Adjustable Cervix Applicator 42
Arnhem Bile Duct Applicator 96
B Bevel Point Needles 105
Bile Duct 94
Bladder 68
Bonvoisin-Gérard Esophageal Applicator Set 56
Breast 60
Breast CT/MR Template Set 62
Bronchus 50
C Cervix Rotterdam Applicator Set 12
CT/MR Applicator Clamp 111
E Emergency Button Cutter 107
Esophagus 50
Esophageal Applicator Set 58
F Fletcher Williamson Applicator Sets 14
Fletcher CT/MR Applicator Set 10
Flexible Implant Tubes 106
Freiburg Flap Applicator Set 84
Fritz Adjustable Intralumenal Applicator Set 54
G Gynecology 6
H Head & Neck 86
Henschke Titanium Applicator Set 18
Index
116 117
I Interstitial Ring CT/MR Applicator Set 20
Intracavitary Mold Applicator Set 76
Intrauterine Tube (d=4 mm) 47
K Kink Protection Tubes 107
Kuske Breast Applicator Set 64
L Leipzig Applicator 82
Lumencath Applicator Set 52
M Martinez Prostate Template Set 70
Metal Interstitial Needles 102
MR Line Marker Set 48
Miami Vaginal Applicator Set 38
MUPIT Applicator Set 74
N Needles & Flexible Implant Tubes 98
Norman Simon Applicator Set 44
O OncoSmart Catheter System 66
OncoSmart ProGuide CT-Marker Sets 101
P Pancreas 94
Patient Belt Coupling 112
Pipard Tongue Template Set 92
ProGuide Needles & Markers 104
Prostate 68
Prostate Stepper Template Set 72
Push Fit Disconnection Tool 107
Q Quality Assurance & Accessories 108
Quality assurance for source positioning 110
R Rectum 68
Ring Applicator Set 26
Ring CT/MR Applicator Set 24
Rotte Endometrial Applicator Set 46
Rotterdam Nasopharyngeal Mold 90
S Shielded Cylindrical Applicator Set 36
Skin & Surface 78
Smit Sleeve 49
Source Position Check Ruler 110
Source Position Simulator 110
Standard CT/MR Applicator Set 16
Standard Nasopharyngeal Applicator Set 88
T Ti Vaginal Cylinder Applicator Set 34
U Utrecht Interstitial CT/MR Applicator Set 8
V Vaginal Applicator Set 40
Vaginal CT/MR Applicator Set 32
Vaginal CT/MR Multi Channel Applicator Set 30
Vaginal Mold Applicator Set 28
Valencia Skin Applicator 80
Vienna Ring CT/MR Applicator Set 22
118 119
X-ray, CT and MRI Markers for Flexitron
The appropriate X-ray and CT-markers for use of a specific applicator with your afterloader can be selected with this table. If no crossmatch is indicated in this table, it is not possible to connect that applicator and afterloader.
X-Ray Catheter Set CT/MR GYN (for Flexitron)
X-Ray Catheter Set GYN SS (for Flexitron)
GYN X-ray Marker Set
X-Ray Catheter Set 30 cm X-Ray Catheter Set 50 cm
CT Marker Set 200 mm CT Marker Set 240 mm CT Marker Set 294 mmMR Line Marker Setmetal, 6
markersmetal, 12 markers
metal, 18 markers
black, 6 markers
black, 12 markers
black, 18 markers
yellow, 6 markers
yellow, 12 markers
yellow, 18 markers
Forchannel: 1-3-5 1-9 10-18 1-18 19-30 1-9 10-18 19-30
Partnumber: 110.400 110.570 137.070 089.082 089.083 089.420 189.850 089.089 089.090 189.851 110.285 189.691 189.034 110.286 189.692 189.036 110.287 189.693 189.039 110.290
Bodysite Part number Description
Gynecology 084.450 AdjustableCervixApplicatorSet x
Gynecology 137.206/217/218 CervixRotterdamApplicatorSets x
Gynecology 189.730 FletcherCT/MRApplicatorSet x x
Gynecology 085.230/260 FletcherWilliamsonApplicatorSets x
Gynecology 110.018 HenschkeTitaniumApplicatorSet x
Gynecology 110.330/331/332A01/02 InterstitialRingCT/MRApplicatorSets x x x x x x x
Gynecology 085.210 MiamiVaginalApplicatorSet x x
Gynecology 084.050 RingApplicatorSet x
Gynecology 101.035/060/061/062 RingCT/MRApplicatorSets x x
Gynecology 084.434 RotteEndometrialApplicatorSet x
Gynecology 084.320 ShieldedCylindricalApplicatorSet x
Gynecology 101.020 StandardCT/MRApplicatorSet x x
Gynecology 137.400 TIVaginalCylinderApplicatorSet x
Gynecology 110.270A01/02 UtrechtInterstitialCT/MRApplicatorSets x x x x x x x
Gynecology 084.350 VaginalApplicatorSet x
Gynecology 101.001 VaginalCT/MRApplicatorSet x x
Gynecology 110.750 VaginalCT/MRMultiChannelApplicatorSet x x x x x x x
Gynecology 189.018 VaginalmoldApplicatorSet x
Gynecology 189.569/699/792 ViennaRingCT/MRApplicatorSets x x x x x
Breast 110.518 BreastCT/MRApplicatorSet DependingonuseofOncoSmartcathetersortypeofneedles
Breast 189.006 KuskeBreastApplicatorSet x x x x
Breast 103.111 Oncosmart Introduction Set x x x
Prostate,rectum 189.011 IntracavitaryMoldApplicatorSet
Prostate,rectum 083.570/571,089.055/056 MUPITApplicatorSets x x x x
Prostate,rectum 189.069 ProstateStepperTemplateSet5F x x x x x x x
Prostate,rectum 189.070 ProstateStepperTemplateSet6F x x x x x x x
Skin 089.095 FreiburgFlapApplicatorSet x x x x
Skin 085.040 LeipzigApplicatorSet
Skin 189.701 ValenciaSkinApplicatorSet
Head&Neck 045.410 PipardTongueTemplateSet x
Head&Neck 089.068 RotterdamNasopharyngealMold x
Head&Neck 085.065 StandardNasopharyngealApplicatorSet x
Needles various TitaniumNeedleSets(TrocarPoint) x x x x x x x x x x
Needles various Stainlesssteelneedles(Interstitial/Trocarpoint/Bevelpoint) x x x x
Needles various ProGuideRound/SharpNeedleSet5Fx240mm x x x x x x x
Needles various ProGuideRound/SharpNeedleSet6Fx200mm x x x
Needles various ProGuideRound/SharpNeedleSet6Fx240mm x x x
Needles various ProGuideRound/SharpNeedleSet6Fx294mm x x x x x x
FlexibleImplantTubes various FlexibleImplantTubes,5F/6F,30cm x x x x
Note: *MarkersforBronchusandEsophagusapplicatorsareincludedintheapplicatorSet
Transfer Tubes for Flexitron
The appropriate Transfer Tube Set to connect a specific applicator to your afterloader can be selected with this table. If no crossmatch is indicated in this table, it is not possible to connect that applicator and afterloader.
Transfer Tube Set for GYNTransfer Tube Set for Skin
Transfer Tube Set for Metal needles Transfer Tube Set 4F Transfer Tube Set 5F Transfer Tube Set 6FCT/MR ap-plicators
Stainless steel ap-plicators
Titanium applicators
Forchannel: 1-3-5 1-3-5 1-3-5 5 1-10 11-20 21-30 31-40 1-10 11-20 21-30 31-40 1-10 11-20 21-30 31-40 1-10 11-20 21-30 31-40
Partnumber: 111.650 111.680 137.063 111.683 111.805 111.816 111.827 111.838 111.850 111.861 111.872 111.883 137.090 137.091 137.092 137.093 137.094 137.095 137.096 137.097
Bodysite Part number Description
Gynecology 084.450 AdjustableCervixApplicatorSet x
Gynecology 137.206/217/218 CervixRotterdamApplicatorSets x
Gynecology 189.730 FletcherCT/MRApplicatorSet x
Gynecology 085.230/260 FletcherWilliamsonApplicatorSets x
Gynecology 110.018 HenschkeTitaniumApplicatorSet x
Gynecology 110.330/331/332A01/02 InterstitialRingCT/MRApplicatorSets x x x
Gynecology 085.210 MiamiVaginalApplicatorSet x x
Gynecology 084.050 RingApplicatorSet x
Gynecology 101.035/060/061/062 RingCT/MRApplicatorSets x
Gynecology 084.434 RotteEndometrialApplicatorSet x
Gynecology 084.320 ShieldedCylindricalApplicatorSet x
Gynecology 101.020 StandardCT/MRApplicatorSet x
Gynecology 137.400 TiVaginalCylinderApplicatorSet x
Gynecology 110.270A01/02 UtrechtInterstitialCT/MRApplicatorSets x x x
Gynecology 084.350 VaginalApplicatorSet x
Gynecology 101.001 VaginalCT/MRApplicatorSet x
Gynecology 110.750 VaginalCT/MRMultiChannelApplicatorSet x x x
Gynecology 189.018 VaginalmoldApplicatorSet x
Gynecology 189.569/699/792 ViennaRingCT/MRApplicatorSets x x x
Breast 110.518 BreastCT/MRApplicatorSet DependingonuseofOncoSmartcathetersortypeofneedles
Breast 189.006 KuskeBreastApplicatorSet x x x x
Breast various OncoSmartCatheterSets x x x x
Prostate,rectum 189.011 IntracavitaryMoldApplicatorSet
Prostate,rectum 083.570/571,089.055/056 MUPITApplicatorSets x x
Prostate,rectum 189.069 ProstateStepperTemplateSet5F x x
Prostate,rectum 189.070 ProstateStepperTemplateSet6F x x
Skin 089.095 FreiburgFlapApplicatorSet x x x x
Skin 085.040 LeipzigApplicatorSet x x
Skin 189.701 ValenciaSkinApplicatorSet
Head&Neck 045.410 PipardTongueTemplateSet DependingonuseofFlexibleImplants
Head&Neck 089.068 RotterdamNasopharyngealMold x
Head&Neck 085.065 StandardNasphharyngealApplicatorSet x
Needles various TitaniumNeedleSets(TrocarPoint) x x x x
Needles various Stainlesssteelneedles(Interstitial/Trocarpoint/Bevelpoint) x x x x
Needles various ProGuideNeedles5F x x x x
Needles various ProGuideNeedles,6F x x x x
FlexibleImplantTubes various FlexibleImplantTubes5F x x x x
FlexibleImplantTubes various FlexibleImplantTubes6F x x x x
Note *Bileduct,BronchusandEsophagusapplicatorSetsincludeadapterstoinserttheapplicatordirectlyintheindexer
120 121
Transfer Tubes for microSelectron
With this table, the appropriate Transfer Tube Set can be selected to connect a specific applicator to your afterloader. If no crossmatch is indicated in this table, it is not possible to connect that applicator and afterloader.
Transfer Tube Set for GYNTransfer Tube Set for Skin
Transfer Tube Set for Needles Transfer Tube Set 4F Transfer Tube Set 5F Transfer Tube Set 6FStainless steel ap-plicators
CT/MR ap-plicators
Titanium applicators
Forchannel: 1-3 1-3 1-3-5 3 1-9 10-18 19-30 1-9 10-18 19-30 1-9 10-18 19-30 1-9 10-18 19-30
Partnumber: 111.001 111.006 111.100 111.004 111.011 111.021 111.140 111.071 111.081 111.600 111.051 111.061 111.614 111.031 111.041 111.628
Bodysite Part number Description
Gynecology 084.450 AdjustableCervixApplicatorSet x
Gynecology 089.079 BasicNormanSimonApplicatorSet x
Gynecology 137.206/217/218 CervixRotterdamApplicatorSets x
Gynecology 189.730 FletcherCT/MRApplicatorSet x
Gynecology 085.230/260 FletcherWilliamsonApplicatorSets x
Gynecology 110.018 HenschkeTitaniumApplicatorSet x
Gynecology 110.330/331/332A01/02 InterstitialRingCT/MRApplicatorSets x x x
Gynecology 085.210 MiamiVaginalApplicatorSet x x
Gynecology 084.050 RingApplicatorSet x
Gynecology 101.035/060/061/062 RingCT/MRApplicatorSets x
Gynecology 084.434 RotteEndometrialApplicatorSet x
Gynecology 084.320 ShieldedCylindricalApplicatorSet x
Gynecology 101.020 StandardCT/MRApplicatorSet x
Gynecology 137.400 TiVaginalCylinderApplicatorSet x
Gynecology 110.270A01/02 UtrechtInterstitialCT/MRApplicatorSets x x x
Gynecology 084.350 VaginalApplicatorSet x
Gynecology 101.001 VaginalCT/MRApplicatorSet x
Gynecology 110.750 VaginalCT/MRMultiChannelApplicatorSet x x x
Gynecology 189.018 VaginalmoldApplicatorSet x
Gynecology 189.569/699/792 ViennaRingCT/MRApplicatorSets x x x
Breast 110.518 BreastCT/MRApplicatorSet DependingonuseofOncoSmartortypeofneedles
Breast 189.006 KuskeBreastApplicatorSet x x x
Breast various OncoSmartCatheterSets x x x
Prostate,rectum 189.011 IntracavitaryMoldApplicatorSet x x
Prostate,rectum 083.570/571,089.055/056 MUPITApplicatorSets x x
Prostate,rectum 189.069 ProstateStepperTemplateSet5F x x
Prostate,rectum 189.070 ProstateStepperTemplateSet6F x x
Skin 089.095 FreiburgFlapApplicatorSet x x x
Skin 085.040 LeipzigApplicatorSet x x
Skin 189.701 ValenciaSkinApplicatorSet x x
Head&Neck 045.410 PipardTongueTemplateSet DependingonuseofFlexibleImplants
Head&Neck 089.068 RotterdamNasopharyngealMold x
Head&Neck 085.065 StandardNasphharyngealApplicatorSet x
Needles various TitaniumNeedleSets(TrocarPoint) x x x
Needles various Stainlesssteelneedles(Interstitial/Trocarpoint/Bevelpoint) x x x
Needles various ProGuideNeedles5F x x x
Needles various ProGuideNeedles,6F x x x
FlexibleImplantTubes various FlexibleImplantTubes,5F x x x
FlexibleImplantTubes various FlexibleImplantTubeSet,6F x x x
Note *Bileduct,BronchusandEsophagusapplicatorSetsincludeadapterstoinserttheapplicatordirectlyintheindexer
X-ray, CT and MRI Markers for MicroSelectron
The appropriate X-ray and CT-markers for use of a specific applicator with your afterloader can be selected with this table. If no crossmatch is indicated in this table, it is not possible to connect that applicator and afterloader.
X-Ray Catheter Set, Standard GYN
X-ray Catheter Set, USA GYN
X-Ray Catheter Set CT/MR GYN
GYN X-ray Marker Set, 300 mm
X-ray Catheter Set, Norman Simon
X-Ray Catheter Set 30 cm X-Ray Catheter Set 50 cmX-Ray Catheter 100 cm
CT Marker Set 200 mm CT Marker Set 240 mm CT Marker Set 294 mmMR Line Marker Setmetal, 6
markersmetal, 12 markers
metal, 18 markers
black, 6 markers
black, 12 markers
black, 18 markers
yellow, 6 markers
yellow, 12 markers
yellow, 18 markers
Forchannel: 1-3-5 1-9 1-9 10-18 1-18 19-30 1-9 10-18 19-30 1
Partnumber: 085.075 084.880 101.065 137.070 089.096 089.082 089.083 089.420 189.850 089.089 089.090 189.851 089.401 110.285 189.691 189.034 110.286 189.692 189.036 110.287 189.693 189.039 110.290
Bodysite Part number Description
Gynecology 084.450 AdjustableCervixApplicatorSet x x
Gynecology 089.079 BasicNormanSimonApplicatorSet x
Gynecology 137.206/217/218 CervixRotterdamApplicatorSets x
Gynecology 189.730 FletcherCT/MRApplicatorSet x x
Gynecology 085.230/260 FletcherWilliamsonApplicatorSets x x
Gynecology 110.018 HenschkeTitaniumApplicatorSet x x
Gynecology 110.330/331/332A01/02 InterstitialRingCT/MRApplicatorSets x x x x x x x
Gynecology 085.210 MiamiVaginalApplicatorSet x x x x
Gynecology 084.050 RingApplicatorSet x
Gynecology 101.035/060/061/062 RingCT/MRApplicatorSets x x
Gynecology 084.434 RotteEndometrialApplicatorSet x x
Gynecology 084.320 ShieldedCylindricalApplicatorSet x x
Gynecology 101.020 StandardCT/MRApplicatorSet x x
Gynecology 137.400 TIVaginalCylinderApplicatorSet x
Gynecology 110.270A01/02 UtrechtInterstitialCT/MRApplicatorSets x x x x x x x
Gynecology 084.350 VaginalApplicatorSet x x
Gynecology 101.001 VaginalCT/MRApplicatorSet x x
Gynecology 110.750 VaginalCT/MRMultiChannelApplicatorSet x x x x x x x
Gynecology 189.018 VaginalmoldApplicatorSet x x
Gynecology 189.569/699/792 ViennaRingCT/MRApplicatorSets x x x x x
Breast 110.518 BreastCT/MRApplicatorSet DependingonuseofOncoSmartcathetersortypeofneedles
Breast 189.006 KuskeBreastApplicatorSet x x x x
Breast various OncosmartCatheterSets x x x
Prostate,rectum 189.011 IntracavitaryMoldApplicatorSet x
Prostate,rectum 083.570/571,089.055/056 MUPITApplicatorSets x x x x
Prostate,rectum 189.069 ProstateStepperTemplateSet5F x x x x x x x
Prostate,rectum 189.070 ProstateStepperTemplateSet6F x x x x x x x
Skin 089.095 FreiburgFlapApplicatorSet x x x x
Skin 085.040 LeipzigApplicatorSet
Skin 189.701 ValenciaSkinApplicatorSet
Head&Neck 045.410 PipardTongueTemplateSet x
Head&Neck 089.068 RotterdamNasopharyngealMold x
Head&Neck 085.065 StandardNasopharyngealApplicatorSet x x
Pancreas&BileDuct 085.001 ArnhemBileDuctApplicator x
Needles various TitaniumNeedleSets(TrocarPoint) x x x x x x x x x x
Needles various Stainlesssteelneedles(Interstitial/Trocarpoint/Bevelpoint) x x x x
Needles various ProGuideRound/SharpNeedleSet5Fx240mm x x x x x x x
Needles various ProGuideRound/SharpNeedleSet6Fx200mm x x x x x x x
Needles various ProGuideRound/SharpNeedleSet6Fx240mm x x x x x x x
Needles various ProGuideRound/SharpNeedleSet6Fx294mm x x x x x x
FlexibleImplantTubes various FlexibleImplantTubes,5F/6F,30cm x x x x
FlexibleImplantTubes various FlexibleImplantTubes,6F,50cm x x x
Note: *MarkersforBronchusandEsophagusapplicatorsareincludedintheapplicatorSet
Doc
umen
t No.
308
.880
MKT
-[08
] ©20
12 E
lekt
a. A
ll m
enti
oned
trad
emar
ks a
nd r
egis
tere
d tr
adem
arks
are
the
prop
erty
of
the
Elek
ta G
roup
. All
righ
ts r
eser
ved.
N
o pa
rt o
f th
is d
ocum
ent m
ay b
e re
prod
uced
in a
ny fo
rm w
itho
ut w
ritt
en p
erm
issi
on fr
om th
e co
pyri
ght h
olde
r. Sp
ecifi
cati
ons
subj
ect t
o ch
ange
wit
hout
not
ice.
Elekta AB (publ) Box 7593, SE-103 93 Stockholm, Sweden
Tel +46 8 587 254 00 Fax +46 8 587 255 00
Nucletron BV PO Box 930, 3900 AX Veenendaal, The Netherlands
Tel +31 (0)318 557 133 Fax +31 (0)318 550485
Corporate Head Office: Manufacturer:
Asia Pacific
Tel +852 2891 2208 Fax +852 2575 7133
www.nucletron.com | www.elekta.com Human Care Makes the Future Possible
North America
Tel +1 770 300 9725 Fax +1 770 448 6338
Regional Sales, Marketing and Service:
Europe, Middle East, Africa, Eastern Europe, Latin America
Tel +46 8 587 254 00 Fax +46 8 587 255 00
Committed to Brachytherapy
Nucletron,anElektacompany,istheworld-leaderin state-of-the-artbrachytherapysolutionsforcancertreatment.With35yearsofexperience,wearethepreferredpartnerforbrachytherapyinmorethan 1,500institutionsworldwide.Wecontinueourcommitmentwithmorethan500employeesdedicatedtobrachytherapy,aglobalpresenceinmorethan100countries and an ongoing investment in innovation.
Ahumancarecompany,Elektapioneerssignificantinnovations and clinical solutions for treating cancer andbraindisorders.Elektaprovidesintelligentandresource-efficienttechnologiesthatimprove,prolong andsavepatientlives.Wegobeyondcollaboration seekinglong-termrelationshipsbuiltontrustwith asharedvision,offeringconfidencetohealthcareprovidersandtheirpatients.