downflow/horizontal right or downflow/horizontal …...2012/06/22 · downflow/horizontal right or...
TRANSCRIPT
Downflow/Horizontal Right orDownflow/Horizontal LeftInduced Draft Gas Furnace
PUB. NO. 22-1671-10
XR 80TDD1A040A9241A, TDD1A060A9241A, TDD1A060A9361A,TDD1B060A9361A, TDD1B080A9361A, TDD1B080A9451ATDD1B100A9451A, TDD1C100A9481A, TDD1C100A9541ATDD1C120A9541A, TDD1D120A9601A, TDD1D140A9601A
Single-Stage Fan AssistedCombustion System
© 2009 Trane All Rights Reserved 2 22-1671-10
GeneralFeatures
Natural Gas ModelsCentral Heating furnace designs arecertified by the American and CanadianGas Associations for both natural andL.P. gas. Limit setting and rating datawere established and approved understandard rating conditions usingAmerican National Standards Institutestandards.
Safe OperationThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.
Quick HeatingDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure.
BurnersMulti-port In-shot burners will give yearsof quiet and efficient service. All modelscan be converted to L.P. gas.
Integrated System ControlExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self-diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.
Air DeliveryThe 4-speed, direct drive blower motor,has sufficient airflow for most heating andcooling requirements, will switch fromheating to cooling speeds on demandfrom room thermostat. The blower doorsafety switch will prevent or terminatefurnace operation when the blower dooris removed.
StylingHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heatexchanger section of the cabinet iscompletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass.
Features andGeneral OperationThe XR 80 High Efficiency Gas Furnaceemploys an adaptive Hot Surface Ignitionsystem, which eliminates the waste of aconstant burning pilot. The integratedsystem control lights the main burnersupon a demand for heat from the roomthermostat. Complete front serviceaccess.
a. Low energy power venterb. Vent proving pressure switch.
22-1671-10 3
Contents
General Features 2
Features and Benefits 4Standard Equipment 4Optional Equipment 5
General Data 6TDD1A040A9241A 6TDD1A060A9241A 6TDD1A060A9361A 6TDD1B060A9361A 7TDD1B080A9361A 7TDD1B080A9451A 7TDD1B100A9451A 8TDD1C100A9481A 8TDD1C100A9541A 8TDD1C120A9541A 9TDD1D120A9601A 9TDD1D140A9601A 9
Performance Data 10
Electrical Data 12
Field Wiring 14
Dimensions 16
4 22-1671-10
Features andBenefits
• Power supply 115/1/60
• Multi-port In-shot burners
• Integrated solid state control with self-diagnostics
• Silicon Nitride hot surface igniter withadaptive heat up
• Complete front service access
• Heavy gauge aluminized steel heatexchanger
• Slide out blower assembly
• Blower door safety switch
• Direct drive, 4-speed motor
• Optional L.P. conversion kit
• Common vent
• Left and right side knockout for venting
• Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay
• Quiet slow opening gas valve
• Downflow convertible to horizontal onleft or right side
• Insulated blower compartment
• Accessory hook-up capability –Hum and EAC
• Quiet induced draft blower
• Left/right gas connection
• 24 volt fuse
• Manual reset flame rollout switches
XR 80 Downflow/Horizontal Right or LeftStandard Equipment
22-1671-10 5
Features andBenefits
Optional EquipmentThermostat ................................................................................................................................................................ BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................. AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................. BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .............................................................. TAYSTAT300C [ ]Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .........................................................TFM145A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .........................................................TFM175A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ...............................................................TFM210A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .........................................................TFM245A9FR1 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................ TFP175A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................... TFP210A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................ TFP245A9FR01 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ......................................................................................................... BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ......................................................................................................... BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) ............................................................................................................... BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ......................................................................................................... BAYCLE24A2430A [ ]Filter Access Door Kit ............................................................................................................................................... BAYFLTR206 [ ]Downflow Subbase .................................................................................................................................................. BAYBASE205 [ ]High Altitude Pressure Switch Kit ............................................................................................................................. BAYHALT248 [ ]
6 22-1671-10
GeneralData
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
TDD1A040A9241A
Downflow / Horizontal
40,00031,00080.0
30 - 60
DIRECT10 x 6
14
See Fan Performance Table1/5
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot2
115/1/605.415
1/2
H x W x D41 x 15-1/2 x 29-1/2
119 / 109
TDD1A060A9241A
Downflow / Horizontal
60,00048,00080.0
35 - 65
DIRECT10 x 7
14
See Fan Performance Table1/5
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/605.515
1/2
H x W x D41 x 15-1/2 x 29-1/2
129 / 119
TDD1A060A9361A
Downflow / Horizontal
60,00048,00080.0
30 - 60
DIRECT11 x 7
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/6011.615
1/2
H x W x D41 x 15-1/2 x 29-1/2
129 / 119
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
22-1671-10 7
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
TDD1B080A9451A
Downflow / Horizontal
80,00064,00080.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot4
115/1/609.815
1/2
H x W x D41 x 18-1/2 x 29-1/2
146 / 135
TDD1B080A9361A
Downflow / Horizontal
80,00064,00080.0
35 - 65
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot4
115/1/609.015
1/2
H x W x D41 x 18-1/2 x 29-1/2
146 / 135
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDD1B060A9361A
Downflow / Horizontal
60,00048,00080.0
30 - 60
DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/6011.615
1/2
H x W x D41 x 18-1/2 x 29-1/2
134 / 124
8 22-1671-10
GeneralData
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDD1C100A9481A
Downflow / Horizontal
100,00080,00080.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/6011.615
1/2
H x W x D41 x 22 x 29-1/2
166 / 154
TDD1C100A9541A
Downflow / Horizontal
100,00081,00080.0
30 - 60
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 14x20 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/6013.420
1/2
H x W x D41 x 22 x 29-1/2
167 / 155
TDD1B100A9451A
Downflow / Horizontal
100,00080,00080.0
35 - 65
DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3200115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/609.815
1/2
H x W x D41 x 18-1/2 x 29-1/2
156 / 145
22-1671-10 9
Product Specifications 1MODEL
TYPE
RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
TDD1D140A9601A
Downflow / Horizontal
140,000113,000
80.045 - 75
DIRECT11 x 10
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
7 — 457 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot7
115/1/6013.820
1/2
H x W x D41 x 25_-1/2 x 28
196 / 183
TDD1D120A9601A
Downflow / Horizontal
120,00096,00080.0
35 - 65
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot6
115/1/6013.420
1/2
H x W x D41 x 25-1/2 x 29-1/2
189 / 176
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 ft., derate 4% per 1,000 ft. for elevations above 2,000 ft. above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 ft., derate 4% per 1,000 ft. for elevations above 4,500 ft. above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TDD1C120A9541A
Downflow / Horizontal
120,00096,00080.0
35 - 65
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0
NoHigh Velocity
2 - 16x20 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot6
115/1/6013.420
1/2
H x W x D41 x 22 x 29-1/2
170 / 158
10 22-1671-10
PerformanceData
FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
*DD1A040A9241A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
1070870740633
1033850720600
1000823690577
960790663543
920753627507
860813588463
810667547420
740613483360
-490
--
*DD1A060A9241A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
12001025838722
1155988808689
1111951779656
1056905742618
1001859704579
924797646528
848735588478
774646502376
701558415275
*DD1A060A9361A
*DD1B060A9361A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
148013021115956
142912761100947
137512291070918
131811881035888
128211411000859
11001088965824
11121024918788
1029953859741
959882790682
*DD1B080A9361A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
152313171123942
149613071119943
146312611106931
142012421082920
136912231056898
131011751016868
12431122976833
11721060930795
11001000880760
*DD1B080A9451A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
1798138412101005
175013671150970
169213331108808
164213001075775
157512751042767
150012331008733
14251192967700
13251142925675
12251083867617
*DD1B100A9451A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
176713821130840
173113541138831
166913231115815
161512921085792
154612541054762
146912071015731
13921177977700
13001108938654
11461038877625
*DD1C100A9481A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
1965164514071202
1915162713981208
1865160513871205
1805157513751195
1740153513471166
1670148213181140
1587142112751105
1500133011901045
137012201095970
*DD1B100A9541A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2165196217051492
2113192716881467
2060189116711442
1995183916361414
1929178616001385
1842172415471346
1755166214921307
1674158114351243
1593150013771179
*DD1C120A9541A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2100191716721485
2049188716561478
1997185716391470
1958184216311448
1918182716231426
1852175115601388
1785167414961349
1695159414271278
1604151413581207
*DD1D120A9601A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2241198117211476
2202196217051466
2163194216881456
2106190416711440
2049186616531423
1979180516111392
1908174315691361
1804168015151302
1700161714611243
*DD1D140A9601A
4 -3 -2 -1 -
HIGH - BlackMED - HIGH - BlueMED - LOW - YellowLOW - Red
2377211518061527
2321208117931507
2265204617791486
2199199217381473
2133193816961459
2050187216551422
1967180516141384
1877172715561329
1786164914971273
* May be "A" or "T"
22-1671-10 11
PerformanceData
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
TDD1A040A9241A 59 49 42 37 33 30
TDD1A060A9241A 63 56 49 44 40
TDD1A060A9361A 56 49 44 40 37 34 32
TDD1B060A9361A 56 49 44 40 37 34 32
TDD1B080A9361A 59 54 59 46 42
TDD1B080A9451A 64 57 52 48 44 41
TDD1B100A9451A 62 57 53 49 46 44 41
TDD1C100A9481A 62 57 53 49 46 44 41 39 37
TDD1C100A9451A 62 57 53 49 46 44 41 39 37 35 34 32 31
TDD1C120A9541A 59 56 52 49 47 44 42 40
TDD1D120A9601A 59 56 52 49 47 44 42 40
TDD1D140A9601A 69 65 61 58 55 52 49 47 45
12 22-1671-10
(continued on next page)
WIRING DIAGRAM
From Dwg. D342568P01 Rev. 1
22-1671-10 13
SCHEMATIC DIAGRAM
From Dwg. D342568P01 Rev. 1
14 22-1671-10
FieldWiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341437 Rev. 1
From Dwg. 21B341436 Rev. 1
22-1671-10 15
Dimensions
FieldWiring
From Dwg. 21B341423 Rev. 1
From Dwg. 21B341422 Rev. 1
Trane6200 Troup HighwayTyler, TX 75707www.trane.com
Since The Trane Company has a policy of continuous product and product dataimprovement, it reserves the right to change design and specifications withoutnotice.
Literature Order Number 22-1671-10
File Number 22-1671-10
Supersedes 22-1671-09
Date 06/10
Fro
m D
wg.
21C
3417
00 R
ev. 0
TDD
1 O
UTL
INE
DR
AW
ING
(ALL
DIM
EN
SIO
NS
AR
E IN
INC
HE
S)
MO
DE
LD
IM "
A"
DIM
"B
"D
IM "
C"
DIM
"D
"
*DD
1A04
0A92
41A
*DD
1A06
0A92
41A
*DD
1A06
0A93
61A
14-1
/2"
9-5/
8"13
-1/4
"13
"
*DD
1B06
0A93
61A
*DD
1B08
0A93
61A
*DD
1B08
0A94
51A
*DD
1B10
0A94
51A
17-1
/2"
9-5/
8"16
-1/4
"16
"
*DD
1C10
0A94
81A
*DD
1C10
0A95
41A
*DD
1C12
0A95
41A
21"
13-1
/16"
19-3
/4"
19-1
/2"
*DD
1D12
0A96
01A
*DD
1D14
0A96
01A
24-1
/2"
15-5
/16"
23-1
/4"
23"
* P
RE
FIX
LE
TT
ER
MAY
BE
"A
" O
R "
T"