doe run unit 6
TRANSCRIPT
A1
CO
VE
R P
AG
E
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
HOUSE FOOTPRINT INCLUDINGCOVERED PATIO AREAS: 1878 S.F.
NOTE: LOT COVERAGE CALCULATIONS FOR 9-UNITDEVELOPMENT INCLUDED ON PAGE A2.
LOT COVERAGE
DOE RUN
2317 SUNDOWN COURTANACORTES, WASHINGTON
main floor conditioned: 1193 s.f.
upper floor conditioned: 1492 s.f.
total conditioned: 2685 s.f.
garage: 453 s.f.
main fl. covered patio at front: 14 S.F.
main fl. covered patio at back: 176 S.F.
upper fl. covered balcony: 98 s.f.
total covered outdoor space: 288 S.F.
SQ. FT. INFO.
A1 COVER PAGE
A2 overall SITE PLAN
A3 landscape plan
A4 FOUNDATION PLAN
A5 foundation details
A6 MAIN FLOOR PLAN with shear wall notes
A7 UPPER FLOOR PLAN with shear wall notes
A8 LOWER ROOF & UPPER FLOOR FRAMING PLAN
A9 UPPER ROOF FRAMING PLAN & DETAILS
A10 BUILDING SECTIONS
A11 ELEVATIONS NORTH & EAST
A12 ELEVATIONS SOUTH & WEST
S1 STRUCTURAL DRAWINGS
s2 structural drawings
DRAWING INDEX
downspout and footing drains to betightlined in 4" pvc and connected to 12"pvc main line. 12" pvc to be run towardsoutheast of property to detention pondas noted on site plan.
KEEP DRIVEWAYS/PAVED AREAS SLOPING AWAYFROM buildings.
note: for complete drainage plans see civilengineering set page c3 'driveway,drainage, sewer and water plans & detail'and c4 'bioretention swale & pondmodifications details'
DRAINAGE NOTES
house will be heated by furnace located inattic or garage.
water will be heated by tankless waterheater located in garage.
WATER SUPPLIED BY city of anacortes.
GENERAL NOTES
SITE ADDRESS:2317 SUNDOWN COURTANACORTES, WASHINGTON 98221
PARCEL #: P133756ASSESSOR'S TAX #: 4771-100-000-0000QTR: sw, sec: 21, twn: 35, rng: 01PARCEL SIZE: 1.67 acres (73,962 s.f.)
Property owner:doe run at sunset cove estates, llc1004 commercial ave. #547anacortes, washington 98221
PROPERTY INFO.
PARCEL #: P133756
AT SUNSET COVE ESTATES
UNIT 6BUCKLEY
CONTRACTOR TO INSTALL SILT FENCING ON DOWNSLOPE SIDE OF ENTIRE EXTENTS OF EACH SITE UNDERCONSTRUCTION. SILT FENCING TO REMAIN UNTIL ALLCONSTRUCTION IS COMPLETED AND LANDSCAPE IS INPLACE.
IN ADDITION TO SILT FENCING COVER ALLstockpiled soil with straw or visqueen
note: for complete erosion control detailsand specifications see civil engineering setpage c2 'site plan & erosion control &grading' AND PAGE C5 'ECS DETAILS'
EROSION CONTROLNOTES
CONSTRUCTION WILL COMPLY WITH:
BUILDING & STRUCTURAL 2015 IRC
MECHANICAL 2015 IRC
PLUMBING 2015 UPC
ENERGY & VENTILATION 2015 WSEC
BUILDING CODES
OPTION DESCRIPTION CREDITS
ENERGY CREDITS
1A EFFICIENT BUILDING ENVELOPE:vertical fenestration u = 0.28 for every windowslab on grade r-10 perimeter underunconditioned space (garage) & under entire conditioned space. 0.5
2A AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION:all house ventilation met with high efficiencyfan (MAX. 0.35 WATTS/CFM) not interlocked withfurnace fan. blower test results to BE 3.0 AIRCHANGES PER HOUR MAXIMUM. COMPLIANCE BASED ON R402.4.1.2. 0.5
3A HIGH EFFICIENCY HVAC EQUIPMENT:gas furnace with minimum afue of 94% 1.0
5C EFFICIENT WATER HEATING:gas water heater with minimum ef of 0.91 1.5
TOTAL CREDITS 3.5
THIS RESIDENCE IS A MEDIUM DWELLING UNIT (1500 - 5000 S.F.)WHICH WILL REQUIRE 3.5 CREDITS
NOTE: SQUARE FOOTAGE IS MEASURED TO THEOUTSIDE FACE OF WALLS OF ALL FINISHED SPACE.STAIRWELLS ARE COUNTED ONCE, APPROX. HALFON TOP FLOOR, HALF ON BOTTOM. OPEN TOBELOW SPACES ARE NOT INCLUDED INCALCULATIONS. GARAGE AND UNCONDITIONEDAREAS ARE CALCULATED SEPARATELY.
pg # title COMMENTS REVISIONS
MAIN FLOOR FIRE AREA: 1878 S.F.
UPPER FLOOR FIRE AREA: 1636 S.F.
TOTAL FIRE AREA: 3514 S.F.
NEAREST FIRE HYDRANT: 50' TO west OFPROPERTY LINE AS SHOWN ON PAGE A2
FIRE AREA
setback
20'-0"
20'-0
"
20'-0
"
setb
ack
15'-0"
20'-0
"
33'-3 1/2"
129'-11 3
/4"
6'-0"
22'-11 3/4"
2417 sundown ct.1825 s.f. footprint
15'-1"
2413 sundown ct.2142 s.f.footprint
28'-11"
26'-0 3/4"
23'-9 1/
2"
20'-0"
16'-2
3/4
"16
'-0
"
CENTRALCOMMON AREA
2409 sundown ct.1825 s.f.footprint
15'-0"
BUCKLEY
BUCKLEY
BUCKLEY
DARBY
2411 sundown ct.1860 s.f.footprint
2317 sundown ct.1860 s.f. footprint
2311 sundown ct.1860 s.f. footprint
6'-0"
3'-6 3
/4"
15'-0
"3'-6 1/4
"
24'-6"
7'-0
"
8 1/2
"
DARBY
1
2 LOCKHART
3
4
6
5
12'-6"
32'-1
1 3/4
"
5'-9"
66'-11 1/4
"27
'-8 3
/4"
15'-0
"
11'-10"
81'-
1 1/4"
30'-0"
59'-5 1/2
"
35'-0"
1'-6"
20'-0"
8
6"
20'-0
"
1'-0"
20'-0
"
6"
9'-6
3/4"
13'-2 1/4"
20'-0
"20
'-0
"
20'-0
"
20'-0
"
20'-0"
66'-0
"
57'-0
"
41'-0"32'-0"
35'-0
"
41'-
0"
2'-5 3/4" 41'-10"66'-0"54'-6"57'-0"6"
32'-0
"41'-
0"
20'-0
"
setb
ack
20'-0
"
setb
ack
30
'-0
"
COM
MON/B
UFFER
66'-0"
59'-5 1/2"
37'-9
3/4
"
20'-0
3/4
"
20'-0
"
EXIST. PONDACCESS
sd
sdco
project datumtop of monument incase elev. = 115.83'
exist. 12" a
ds
sd
sd
sd
ss
ss
8"
pvc s
s
sscoss
wa
wa
ss
ssco
ex.ssco
ssco
watermeters
sd
sd
sd
slope0.75%
COM
MON D
RIVE 1
COMMON DRIVE 2
wa
WATER
WATER
ex. sDex. sS
EX. W
ATER
EX. SD
EX. SD
SS
SD
EX. WATER
EX. WATE
R
EX. WATER
EX. FIREHYDRANT
ss
ex. WATER
SS
WA
watermeters
water
wa
wa
WATER
EX. 12
" ADS S
D
SS
SS
SS
SS
SWALE
SS
EX. SS
EX. S
S
SDCO EX. SD
EX. S
D
EX. SD
SD
SDCO EX. SD
SD
SD
50
'-0
"
SLOPE
1%
EX. WATE
R
20' SANITARY SEWER EASEMENT
(EXIST. BUILDING)
(EXIST. BUILDING)
WA
DARBY
2319 sundown ct.1825 s.f. footprint
9
LOCKHART2315 sundown ct.2142 s.f. footprint
7
57'-0"
20'-0"
setback
24'-9 1/2"
59'-5 1/2"
10'-0
"
10' utilityeasement
10'-0"10'-0"
10' utilityeasement
35'-0
"
LOCKHART2309 sundown ct.2142 s.f.footprint
(alt version)
(alt version)
32'-0
"
PAVED COMMON DRIVE
PAVED DRIVEWAY
CENTRAL COMMON AREA
PROPERTY LINE
BUILDING SETBACK
LINE OF BUILDING FOOTPRINT
UTILITY LINE
PAVED COMMON DRIVE
PAVED DRIVEWAY
CENTRAL COMMON AREA
PROPERTY LINE
BUILDING SETBACK
LINE OF BUILDING FOOTPRINT
UTILITY LINE
OV
ER
ALL S
ITE
PLA
N
OVERALL SITE PLAN
UNIT # BUILDING FOOTPRINT (INCL.
COVERED PORCHES)
LOT COVERAGE
BUILDING FOOTPRINTS
PAVED SURFACES
COMMON AREA
COMMON DRIVES 5114 S.F.
DRIVEWAYS 5745 S.F.
TOTAL PAVED: 10,859 S.F.
CENTRAL COMMON AREA 6154 S.F.
DOE RUN AT SUNSET COVE ESTATESOVERALL SITE PLAN
for complete erosion control details andspecifications see civil engineering setpage c2 'site plan & erosion control &grading' AND PAGE C5 'ECS DETAILS'
FOR COMPLETE DRAINAGE PLANS SEE CIVILENGINEERING SET PAGE C3 'DRIVEWAY,DRAINAGE, SEWER AND WATER PLANS & DETAIL'AND C4 'bioretention swale & pondmodifications details'
A2
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
PROJECT DETAILSDOE RUN AT SUNSET COVE ESTATES IS A 9-UNITDEVELOPMENT, FEATURING 3 DIFFERENT HOUSEMODELS: DARBY, BUCKLEY, AND LOCKHART.THERE WILL BE 3 OF EACH MODEL, PLACED ASSPECIFIED IN THE OVERALL SITE PLAN.
lot is 1.67 acres (73,962 s.f.)
EROSION CONTROL& DRAINAGE NOTES
LEGEND
UNIT 1 1825 S.F.
UNIT 2 1878 S.F.
UNIT 3 2124 S.F.
UNIT4 1825 S.F.
UNIT 5 1825 S.F.
UNIT 6 1878 S.F.
UNIT 7 2142 S.F.
UNIT 8 1878 S.F.
UNIT 9 2124 S.F.
TOTAL BUILDINGS: 17,481 S.F.
1
2 3
4
COM
MON D
RIVE 1
COMMON DRIVE 2
(EXIST. BUILDING)
(EXIST. BUILDING)
OB
SE
RV
ATIO
N A
VE
NU
E
SUNDOWNCOURT
EXISTING TREESEXISTING TREES
EXISTINGTREES
CENTRALCOMMON AREA
natural vegetation
natural vegetation
naturalvegetation
6
58
9
7
EVERGREEN TREE
DECIDUOUS TREE
SHRUB/BUSH
PAVED SURFACE
GRASS
PROPERTY LINE
BUILDING SETBACK
LINE OF BUILDING FOOTPRINT
LA
ND
SC
AP
E P
LA
N
LANDSCAPE PLAN
DOE RUN AT SUNSET COVE ESTATESLANDSCAPE PLAN
A3
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
LEGEND
approximately 43,000 s.f. of the 73,962 s.f.lot will be landscaped with either grass orplanted areas (this is approximately 58% OFTHE LOT).
along the edges of the east and southproperty lines there already exists anabundance of trees in the naturalvegetated area. these trees will all beretained, as much as possible. grass will beplanted up to this natural vegetation area.these trees that are retained in the naturalvegetation area will be included in the totalcount of 1 tree per 1000 s.f. of property: 74trees total. additional trees will be plantedas needed throughout parcel, in order toequal the total number of 74.
no more than 30% of new trees planted willbe of the same species.
evergreen trees shall be min. 8' tall, whiledeciduous trees shall have min. 1 1/2" caliperat chest height.
LANDSCAPE NOTES
16'-0" 16'-0"
66'-0
"
11'-0"21'-0"
32'-0"
6'-4"
5'-8"
16'-3"2'-10 1/2"
43'-0
"11'-0
"
3'-11 3/4"
3'-11 3
/4"
2'-10"1'-1 3/4"
45Á
1'-7 1/4
"
4" concRETE slab w/ 6 X 6 X10/10 WWM, over 6 mil POLYvapor barrier, OVER 2" RIGIDINSULATION AROUND EDGES, OVER4" compacted GRANULAR fill
1'-4" x 12" THICKENED FOOTINGW/ (2) #4 BARS (TYP.)
21'-6"
21'-6"
1'-6" X 1'-6" THICKENEDFOOTING at corner W/(3) #4 REBAR BOTH WAYS
4" conc. slab w/ wire mesh on4" thick min. compacted fill
4" concRETE slab w/ 6 X 6 X 10/10WWM, over 6 mil POLY vaporbarrier, OVER 2" RIGID INSULATION,OVER 4" compacted GRANULAR fill
8'-10
1/2
"15
'-4 3
/4"
15'-10
3/4
"11'-2
1/2"
32'-0"
66'-0
"
22'-0" 10'-0"
4'-10"
10'-6"
11'-0
"
2'-6" X 2'-6" reinforced ftgw/ (5) #4 bars each way
4'-0"
2' X 2' X 18" THICKREINFORCED SLAB W/ (3) #4REBAR EACH WAY REQUIREDBELOW ALL GIRDER TRUSSPOINT LOADS
a5
1
a5
1
a5
1
a5
7
a5
7
a5
3
a5
4
a5
2
a5
5
a5
6
a5
8
(2) sstb20 or perdetail 'a', s1
2'-6" X 2'-6" reinforced ftgw/ (5) #4 bars each way
(1) sstb20 or perdetail 'a', s1
2'-6" X 2'-6" reinforced ftgw/ (5) #4 bars each way
2'-6" X 2'-6" reinforced ftgw/ (5) #4 bars each way
14'-7
1/2"
16" wide x 10" thickreinforced slab atbase of stairs with(2) #4 rebar cont.
4'-9"
(4) sstb20 or per detail 'a', s1
a5
3
1'-10 1/2"
6'-0
"
5'-5 3/4"
a5
4
slope garage slabfor drainage
block outfor 3' dooras needed
3'-3" 9'-3 1/2"9'-5 1/2"
FOUNDATION LEGEND
foundation stem wall
foundation footing
OUTLINE OF WALLS OFSUPPORTED FLOOR
A4
FO
UN
DA
TIO
N P
LA
N
FOUNDATION PLAN
WRITTEN DIMENSIONS TAKE PRECEDENCE OVERSCALED DIMENSIONS. VERIFY ALL DIMENSIONS ANDCONDITIONS IN THE FIELD.
ENGINEERING SPECIFICATIONS, NOTES AND DRAWINGSACCOMPANIED WITH PLANS TO SUPERCEDE ALLINFORMATION ON ARCHITECTURAL DRAWINGS. FORANY DISCREPANCIES BETWEEN ENGINEERING ANDARCHITECTURAL DRAWINGS REFER TO ENGINEERING.
FOOTINGS ARE TO BEAR ON UNDISTURBED LEVELSOIL DEVOID OF ANY ORGANIC MATERIAL ANDSTEPPED AS REQUIRED TO MAINTAIN 18" DEPTHBELOW GRADE.
COVER CRAWL SPACE GRADE WITH HIGH DENSITYPOLYETHYLENE HIGH QUALITY VAPOR RETARDER.LAP EDGES 12" MIN. AND EXTEND 12" MIN. UPFOUNDATION WALL.
FILL UNDER SLABS ON GRADE TO BE MIN. 4" DEPTHGRANULAR MATERIAL COMPACTED TO 95%.
CONCRETE SLABS TO HAVE CONTROL JOINTS AT 25'MAX. INTERVALS EACH WAY.
CONCRETE SIDEWALKS TO HAVE 3/4" TOOLED JOINTSAT 5" O.C. EACH WAY.
WIRE MESH TO BE USED IN CONCRETE SLABS,POSITIONED 1-1/2" FROM BOTTOM OF SLAB.
USE HIGH DENSITY POLYETHYLENE HIGH QUALITYVAPOR RETARDER UNDER CONCRETE SLABS INGARAGE AND BASEMENT.
A WATERPROOF MEMBRANE IS TO BE USED ONFOUNDATION WALLS BELOW GRADE.
A DRAIN TILE WITH HOLES, NOT SLITS, IS TO BE USED.DRAIN TILE IS TO BE POSITIONED SO THAT HOLESARE FACING DOWN.
A LAYER OF ROUND, WASHED, DRAINAGE-GRADEGRAVEL IS TO BE USED OVER DRAIN TILE, NEXT TOFOOTINGS. 30-LB. FELT PAPER IS TO BE USED OVERTHE GRAVEL.
ALL BOTTOM PLATES AND ANY LUMBER IN CONTACTWITH CONCRETE TO BE PRESSURE TREATED.
BEAM POCKETS IN CONCRETE TO HAVE 12"AIRSPACE AT SIDES & ENDS WITH MIN. BEARING OF 3".
FOLLOW ALL JOIST FRAMING DETAILS PERMANUFACTURER.
PROVIDE BLOCKING ABOVE ALL BEARING WALLSAND BEAMS.
ALL CONNECTORS AND FASTENERS IN CONTACT WITHPRESSURE TREATED WOOD SHALL BE HOT DIPPEDGALVANIZED OR EQUIVALENT PROTECTION.
ACCESS SHALL BE PROVIDED TO ALL UNDER-FLOORSPACES. ACCESS OPENING THROUGH PERIMETERWALL SHALL BE NOT LESS THAN 18" x 24". IF ANYPORTION OF THROUGH-WALL ACCESS IS BELOWGRADE AN AREAWAY NOT LESS THAN 18" x 24"SHALL BE PROVIDED (IRC R408.4).
CONTRACTOR TO COORDINATE FOUNDATION & SLABBLOCK-OUTS W/ MECH. & ELECT. FOR SIZE &LOCATIONS.
ALL CONCENTRATED LOADS FROM ROOF TRUSSESMUST BE TRANSFERRED TO THE FOUNDATION WITH ABUILT-UP POST AND FOOTINGS AS REQUIRED. VERIFYLOCATIONS WITH TRUSS ENGINEER AND/ORSTRUCTURAL ENGINEER.
FOUNDATION NOTES
note: there shall be no crawl spacetherefore no crawl space ventilationor crawl space access is needed.
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
2 x 6 studs @ 16" o.c.W/ R-21 INSULATION
(2) #4 REBAR CONT.IN FOOTINGS
SIDING PER ELEVATIONS
GRADE, sloped awayfrom building
UNDISTURBED EARTH
6"
MIN
.
WATERPROOFING MEMBRANECONTINUE OVER FOOTING
8"
8" 5"
1'-6"
1/2" gwb TYP.
1'-6"
MIN
.
r-10 rigid foam insulation
see engineering forrebar specifications
5"
FINISH FLOORING
4" CONCRETE SLAB ON 6 MIL.VAPOR BARRIER
6 x 6 x 10/10 woven wire mesh
10" LONG 1/2" DIA. ANCHORBOLTS @ 4'-0" O.C.
exterior sheathing pershearwall plans pg. s1
p.t. 2 x 6 sill plate
4" MIN. COMPACTED GRANULAR FILL
4" DIA. DOWNSPOUT TIGHTLINE
DRAINAGE GRADE GRAVEL& FILTER FABRIC
4" DIA. PERFORATED DRAIN TILE
(2) #4 REBAR CONT.IN FOOTINGS
UNDISTURBED EARTH
8" 5"
1'-6"
r-10 rigid foam insulation
5"
FINISH FLOORING
4" CONCRETE SLAB ON 6 MIL.VAPOR BARRIER
6 x 6 x 10/10 woven wire mesh
4" MIN. COMPACTED GRANULAR FILL
4" MIN. COMPACTED GRANULAR FILL
4" CONCRETE SLAB W/ WIRE MESHslope away from structure
SLOPE AWAY FROM HOUSE
SEE DETAIL '1' FOR OTHERTYPICAL CALL-OUTS
1/2" gwb typ.
1'-4"
1'-0
"
(2) #4 rebar cont.
8"
p.t. bottom plate
1/2" dia. 10" long anchorbolts @ 4'-0" o.c.
2x stud wall per plan
2 x 6 studs @ 16" o.c.
(2) #4 REBAR CONT.IN FOOTINGS
SIDING PER ELEVATIONS
GRADE, sloped awayfrom building
UNDISTURBED EARTH
6"
MIN
.
WATERPROOFING MEMBRANECONTINUE OVER FOOTING
8"
8" 5"
1'-6"
1/2" gwb option
1'-6"
MIN
.
r-10 rigid foam insulation
see engineering forrebar specifications
5"
4" CONCRETE SLAB ON 6 MIL.VAPOR BARRIER
6 x 6 x 10/10 woven wire mesh
10" LONG 1/2" DIA. ANCHORBOLTS @ 4'-0" O.C.
exterior sheathing pershearwall plans pg. s1
p.t. 2 x 6 sill plate
4" MIN. COMPACTED GRANULAR FILL
4" DIA. DOWNSPOUT TIGHTLINE
DRAINAGE GRADE GRAVEL& FILTER FABRIC
4" DIA. PERFORATED DRAIN TILE
2'-0"
thickened slab @ edge
4" MIN. COMPACTEDGRANULAR FILL
grade
4" CONCRETE SLAB ON 6 MIL.VAPOR BARRIER(4) #4 cont. rebar
as shown
1'-0"
1'-6"
SLOPE AWAY FROM HOUSE
1'-6"
1'-0"
thickened corner
(4) #4 CONT. REBAR AS SHOWN
min
.
DRAINAGE GRADE GRAVEL& FILTER FABRIC
4" MIN. COMPACTED GRANULAR FILL
grade
4" CONCRETE SLAB ON 6 MIL.VAPOR BARRIER
4" DIA. PERFORATED DRAIN TILE
r-10 rigid foam insulation
4" DIA. DOWNSPOUT TIGHTLINE
simpson cpt66z post base
6 x 6 p.t. or cedar post
provide min. required sidecover per manuf. specs
(2) #4 REBAR CONT.IN FOOTINGS
UNDISTURBED EARTH
8" 5"
1'-6"
r-10 rigid foam insulation
5"
FINISH FLOORING
4" CONCRETE SLAB ON 6 MIL.VAPOR BARRIER
6 x 6 x 10/10 woven wire mesh
4" MIN. COMPACTED GRANULAR FILL
SLOPE AWAY FROM HOUSE
SEE DETAIL '1' FOR OTHERTYPICAL CALL-OUTS
r-10 rigid foam insulation
2'-0"
1/2" gwb typ.
3/4" X 8" OFFSETVERIFY W/ DOOR SIZE
SLOPE GARAGE CONC. PAD2" TOWARD GARAGE DOOR
1'-0"
1'-0
"
(2) #4 REBAR CONT.
DRIVEWAY SLAB
COMPACTEDFILL
COMPACTEDFILL
GARAGE DOOR
A5
FO
UN
DA
TIO
ND
ETA
ILS
TYP. FND. WALL DETAIL1
GARAGE WALL DETAIL2
HOUSE @ GARAGE DETAIL3
HOUSE @ PATIO DETAIL4
PATIO EDGE DETAIL5
GARAGE FOOTING DETAIL6
THICKENED FOOTING DETAIL7
POST FOOTING DETAIL8
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
ref
2'-8" 3'-8" 6'-5" 2'-8" 1'-0"
3'-6"
8'-6"
3'-6"
COATS
40
68
6'-0
"
2468
11'-0"21'-0"
32'-0"
10'-0
1/4
"27
'-7
3/4
"8'-10
1/2
"27
'-3"
66'-0
"
66'-0
"
11'-0
"43'-0
"
21'-0
1/2
"16
'-3"
16'-0"16'-0"
32'-0"
40
20 p
ic40
20 p
ic20
20 p
ic80
16 p
ic
80
80
sl
dr
s.g
.
2620
awn
2620
awn
2668
3'-9" 1'-0"
5'-9"
5'-0"
5'-8"
6'-4"
4'-0"
5'-10
1/2
"14
'-7
1/2" 12
'-10
"10
'-6"
3'-11"
3080
16080 o.h. door
STORAGE ORMECHANICAL
3068
EX.FAN
EX.FAN
SD/co
5'-3" 5'-6" 5'-3"
5060 pic 5060 pic
6'-0
"
9'-5 1/2" 6'-6 1/2"
4'-6 1/2
"6'-5 1/2
"
12080 sl dr s.g.
2'-6
"2'-6
"
1'-9"
6'-3 1/2
"9'-11 1/2
"2'-0
"
5'-8 1/2
"
3'-8 1/2
"8'-0
1/2
"8'-0
"5'-0
"
11'-0" 10'-0"
up 16 r
3'-6"
4'-8 1/4
"
4'-3"
9'-3" 3'-11 1/2" 6'-5" 2'-4 1/2"
range hood exhaustfan w/ min. 100 cfmrating
20-MIN. FIRE-RATEDSELF-CLOSING DOOR
1/2" min. gwbgarage to house
WATER HEATER IS REQUIREDTO HAVE A VACUUM RELIEFDEVICE AND TEMPERATURE& PRESSURE RELIEF VALVEPER 2015 UPC 504.6
FURN.
HW
bollard
4'-0" 4'-6"
6'-0
"
(covered patio)
9' ceiling ht.throughout
15'-2"
DIRECT-VENT GASFIREPLACE. CONTRACTORVERIFY MANUF. FRAMINGREQUIREMENTS
DIRECT-VENT GASFIREPLACE. CONTRACTORVERIFY MANUF. FRAMINGREQUIREMENTS
(suggested)
2650 pic 2650 pic
1'-8 1/2" 2'-9" 6'-6 1/2"
2650
csm
t
1'-8 1/2
"4'-7
1/2"
5'-2
3/4
"4'-9 1/2
"
60
20 a
wn
dw
5/8" type 'x' gwb LIDTHROUGHOUT GARAGE,screwed off at 6" o.c.in field and on edges
line of cant. above
C
A10A
A10
b
A10
guar
dr
ail
6 x
6 P.T. O
R
CED
AR P
OST
45Á
1'-0"
b
A10
C
A10A
A10
a7
2
4'-4 1/2
"3'-6"
1'-0
"
SW4
(2) simpson hdu2 w/ sstb20or per detail 'a', s1
SW4
SW4
SWp
SWp
SWp
SWp
SWp
SWp
SWp
SW8SW8
(4) simpson hdu2 w/ sstb20or per detail 'a', s1
SWp
SWp
SWp
SWp
SWp
SWp
SW4
(1) simpson hdu2w/ sstb20 orper detail 'a', s1
BEARING WALL FORSTAIR STRINGER &STAIR LANDING?
STORAGEUNDERLANDING?
A6
MA
IN F
LO
OR
PLA
N
FLOOR PLAN NOTES
STAIR NOTES
WRITTEN DIMENSIONS TAKE PRECEDENCE OVERSCALED DIMENSIONS. VERIFY ALL DIMENSIONS ANDCONDITIONS IN THE FIELD.
CONFIRM ALL DOOR, WINDOW, CLOSET, AND ANYOTHER ROUGH OPENING SIZES WITH OWNER/CONTRACTOR PRIOR TO WALL CONSTRUCTION.
ALL WOOD IN CONTACT WITH CONCRETE MUST BEPRESSURE TREATED MATERIAL. USE CORROSIONRESISTANT FASTENERS WHEN IN CONTACT WITHPRESSURE TREATED LUMBER.
ALL EXTERIOR WALLS (EXCEPT GARAGE) TO BEFRAMED WITH 2 x 6 STUDS AT 16" O.C. ANDSHEATHED WITH 7/16" OSB PLYWOOD OR BETTER WITH15# BUILDING PAPER.
EXTERIOR GARAGE WALLS TO BE FRAMED WITH 2 x 4STUDS AT 16" O.C. AND SHEATHED WITH 7/16" OSBPLYWOOD OR BETTER WITH 15# BUILDING PAPER.
ALL INTERIOR WALLS TO BE FRAMED WITH 2 x 4STUDS AT 16" O.C. AND SHEATHED WITH 1/2" GYPSUMWALLBOARD UNLESS NOTED OTHERWISE.
ALL GLASS TO HAVE LOW E (0.40) GLAZING. GLAZINGIN HAZARDOUS LOCATIONS TO BE TEMPERED PERIRC SECTION R308. SEE R308.4 FOR DEFINITION OFHAZARDOUS AREAS.
PROVIDE SMOKE DETECTORS ON OR NEAR THECEILING OF EACH FLOOR, IN ALL BEDROOMS, ANDJUST OUTSIDE EACH BEDROOM. SMOKE DETECTORSTO BE WIRED TO THE ELECTRICAL SYSTEM WITHBATTERY BACKUP (IRC R317.1 & R317.2).
BEDROOMS TO HAVE AT LEAST ONE WINDOW MEETINGTHE FOLLOWING CONDITIONS: WINDOW SILLS TO BEWITHIN 44" OF FINISHED FLOOR WITH A NET CLEAROPENING OF 5.7 SQ. FT. MIN. THE OPENING TO HAVEMIN. CLEAR OPENING HEIGHT OF 24" AND WIDTH OF20" (IRC SECTION R310).
ALL SHOWER AREAS TO BE FINISHED WITH A SMOOTH,HARD & NON-ABSORBENT MATERIAL TO MIN. 72"ABOVE DRAIN INLET. THIS MATERIAL TO BEINSTALLED OVER WATER RESISTANT PLASTERBOARD.
TOILETS TO BE LOCATED IN AREA WITH MIN. 30"WIDTH OF TOTAL FINISHED CLEARANCE, AND HAVECLEARANCE OF MIN. 21" IN FRONT OF TOILET. TOILETSTO BE LIMITED TO 1.6 GALLONS PER FLUSH.
PROVIDE ATTIC ACCESS WITH REMOVABLE PANELWITH MIN. 22" x 30" OPENING AND 30"UNOBSTRUCTED HEAD ROOM. FRAME WITH 2 x 12MEMBERS.
PROVIDE EXHAUST FAN IN KITCHEN AT MIN. 100 CFMAND BATHROOMS AT MIN. 50 CFM. ALL FANS ANDDRYER EXHAUST TO BE VENTED TO OUTSIDE OFRESIDENCE.
PROVIDE min. 1/2" gwb or equivalent to garageside, between garage and residence and/orgarage and attic (IRC R302.6).
PROVIDE 1-HR. FIRE-RESISTIVE CONST. 5/8" TYPE 'X'GWB ON GARAGE lid for FIRE SEPARATION underhabitable space above garage (IRC R302.6).
DOOR BETWEEN HOUSE AND GARAGE TO BE 1-1/2"THICK SOLID CORE, 20-MIN. self-closingFIRE-RATED DOOR (R302.5.1).
PROVIDE FIRESTOPS AT ALL APPLICABLELOCATIONS, INCLUDING HOLES AND ANY OPEN AREAS.
ALL ELEMENTS AND SWITCHES FOR FURNACE ANDWATER HEATER TO BE 18" MIN. ABOVE SLAB.
STAIRS TO BE FRAMED WITH MIN. (3) 2 x 12STRINGERS, ONE AT EACH SIDE AND ONE AT CENTER.PROVIDE FIRE BLOCKING BETWEEN STRINGERS ATTOP, MIDDLE AND BOTTOM, AND BETWEEN STUDSALONG THE RUN OF THE STAIRS.
MINIMUM HEADROOM CLEARANCE TO BE 6'-8"VERTICALLY ABOVE TREAD NOSING TO NEARESTOBJECT ABOVE.
STAIRS TO HAVE MAX. RISE OF 7-3/4" AND MIN. RUNOF 10" WITH NOSING OF 3/4" TO 1-1/4". NO RISER TOBE LESS THAN 4". DIMENSIONS BETWEEN RISE ANDRUN ARE NOT TO VARY MORE THAN 3/8".
ENCLOSED USABLE SPACE UNDER STAIRS TO BE1-HR. FIRE-RESISTIVE CONST. 5/8" TYPE 'X' GWB.
STAIRWAYS WITH 4 OR MORE RISERS TO HAVE ATLEAST ONE CONTINUOUS HANDRAIL AT 34" - 38"ABOVE TREAD NOSING WITH ENDS RETURNED TOTERMINATE INTO WALL OR NEWEL POST.
HANDRAILS TO HAVE GRIP PORTION NOT LESS THAN1-1/4" OR MORE THAN 2" IN CROSS SECTIONALDIMENSION WITH 1-1/2" BETWEEN WALL AND HANDRAIL.
ALL UNENCLOSED FLOORS, LANDINGS, BALCONIES ORPORCHES THAT ARE MORE THAN 30" ABOVEGRADE OR FLOOR BELOW SHALL BE PROTECTED BYA GUARDRAIL THAT IS MIN. HEIGHT OF 36".
OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILSSUCH THAT A 4" DIA. SPHERE CANNOT PASSTHROUGH AT ANY POINT.
GUARDRAILS SHALL BE ATTACHED TO THESTRUCTURE IN SUCH A MANNER TO WITHSTAND ASINGLE CONCENTRATED LOAD OF 200 LBS. APPLIEDIN ANY DIRECTION AT ANY POINT ALONG THE TOP.
GUARDRAIL NOTES
MAIN FLOOR PLAN
UNLESS NOTED OTHERWISE, SHEAR WALLS TO BESWP, PRESCRIPTIVE SHEAR WALL. 7/16" OSB OR15/32" PLY ON ONE SIDE OF WALL, UNBLOCKED,WITH 8D NAILS AT 6" O.C. ALONG EDGES, 12" O.C.IN THE FIELD. HOLD DOWNS ARE NOT REQUIRED.
SHEAR WALL 4 PER SHEAR WALL TABLE, S1.7/16" OSB OR 15/32" PLY ON ONE SIDE OF WALL,BLOCKED, WITH 8D NAILS AT 3" O.C. ALONGEDGES, 12" O.C. IN THE FIELD. HOLD DOWNS AREREQUIRED.
SHEAR WALL 8 PER SHEAR WALL TABLE, S1.7/16" OSB OR 15/32" PLY ON BOTH SIDES OFWALL, BLOCKED, WITH 8D NAILS AT 4" O.C.ALONG EDGES, 12" O.C. IN THE FIELD. HOLDDOWNS ARE REQUIRED.
SWp
sw4
SHEAR WALL PLANSSEE SHEAR WALL TABLE, S1 FOR MORE INFORMATION
sw8
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
1'-6"
8'-11"
1'-6"
2868
16'-0"12'-0"
CLO
SET
3'-6"
2668
linen
1668
2868
2868
2468
60
50
sl
60
50
sl
2040
csm
t20
60
csm
t20
60
csm
t
2040
csm
t
2668
3'-4"8'-2 1/2"
49'-6"
4'-0
"
55'-6"
4'-0"
2'-0
"46'-0
"3'-6"
55'-6"
4'-0
"
6'-11"
7'-0
1/2
"12'-2
1/2"
5'-11 1/2
"13
'-10
1/2
"
15'-5"
11'-4"
2'-4
1/2
"
5'-9 1/2
"
2'-4
1/2
"
12'-2
1/2"
16'-0"16'-0"
32'-0"
10'-10 1/2"5'-1 1/2"2'-11 1/2"13'-0 1/2"
32'-0"
vaulted
STORAGE
5068
wd
2868
2 x 6
2650 csmt2650 pic 2650 pic 2650 csmt
2650 csmt 2650 csmt2650 pic
2640 pic
tub
shower
8080 sl dr s.g.
5040 sl s.g.
2868 barn dr
3068
vaulted
9' ceiling ht.
9' ceiling ht.
9' ceiling ht.
closet
5068
50
68
cab/shlv
furn. chaseif needed
atticaccess
WHOLE HOUSE
EX.FAN
SD/co
EX.FAN
EX.FAN
3'-4 1/2
"3'-8"
5'-0
1/2
"7'-2
"1'-
8 1/2
"12'-2"
1'-8 1/2"2'-3 1/2"
guar
dr
ail
DN 16 r
EX.FAN
SD
SD
SD 1'-6"
built-in
2'-0
"
2'-0
"11'-7"
1'-10
"5'-6 1/4
"5'-9 3
/4"
9'-2 1/2" 4'-1 1/2"
2'-8
1/2
"
3'-3"
4'-1"
4'-11 1/2
"
8'-1 1/2"
3'-6"
8'-4"
3'-4"
3'-5 1/2
"6'-9 1/2
"
8'-1 1/2"
4'-1"
2'-1"4'-0"
3'-11 1/2"6'-11"1'-1 1/2"
1'-9"
4'-0
1/2
"
3'-3" 2'-9" 2'-9" 3'-3" 3'-10 1/2" 2'-9" 2'-9" 2'-9" 3'-10 1/2"
2640
pic
3'-3 3/4" 7'-6 3/4"8'-2 3/4" 4'-9 3/4"
6 x
6 pos
t
6 x
6 pos
t
guardrail
Note: s.g. =safety glass
LINE OF FLOOR BELOW
2 x 6
C
A10A
A10
b
A10
b
A10
C
A10A
A10
a7
1
2'-9
"
SD2'-1"
4'-0"13'-4"
SWp
SWp
SWp
SWp
SWp
SWp SWp
SWp SWp
SWp
SWp
SWp
SWp
SW0 SW0
SW0 SW0
SWp
3/4" T & G PLYWOODOR OSB SUBFLOOR
FIRE BLOCKING
5/8" TYPE "X" GYP. BOARD ONALL SURFACES OF USABLESPACE UNDER STAIRS
(3) 2 x 12 STRINGERS
JOIST PER PLAN
PLYWOOD HANGERBOARDFASTENED TO CARRIAGES
bearing wall
7-3/4
"M
AX.
10" MIN.
RIS
ER
TOP OF HANDRAIL
MAIN
TAIN
6'-8"
MIN
. HEAD
ROOM
4" M
IN.
SEE STAIR NOTES ONPAGE A3.1 FOR STAIR& HANDRAIL NOTES
single steel stringer
3'-0
"EXTEND TO TOP& BOTTOM RISERRETURN TO WALL
concrete slab
1'-4"
10"
16" wide x 10" thick reinforcedslab at base of stairs with (2)#4 rebar cont.
4" thick glulam beamtreads
A7
UP
PE
R F
LO
OR
PLA
N
UPPER FLOOR PLAN
CONTRACTOR TO ADD ADDITIONAL FRAMING ORBLOCKING AS REQUIRED TO MEET CURRENT ENERGYCODE REQUIREMENTS.
AIR LEAKAGE. SOLE PLATE IS TO BE CAULKED ORGLUED TO FLOOR. RIM JOIST BETWEEN STORIES TO BECAULKED/SEALED. ALL HOLES IN BUILDING ENVELOPEARE TO BE CAULKED/SEALED INCLUDING BUT NOTLIMITED TO ELECTRICAL, PLUMBING & HVACPENETRATIONS. OUTLETS, SWITCH BOXES ANDRECESSED FIXTURES ON EXTERIOR WALLS OR CEILINGSARE TO BE CAULKED/SEALED WITH APPROVEDSEALANT, OR HAVE FOAM GASKETS INSTALLED. ALLRECESSED LIGHTS ARE TO BE IC RATED, AIR TIGHT &SEALED TO SURROUNDING GWB. ROUGH OPENINGAROUND ALL WINDOWS & DOORS TO BESEALED/CAULKED.
ALL CEILING EXHAUST FAN DUCTING TO BE INSULATEDAS PER CODE, TO HAVE AS FEW BENDS AS POSSIBLE,AND TO TERMINATE AT THE EXTERIOR OF THE BUILDING.
INSULATION TO FILL ALL EXTERIOR WALL CAVITIES. DONOT COMPRESS. CUT TO FIT AROUND WIRES, PIPES &OUTLET BOXES.
ALL HVAC DUCTS INSTALLED OUTSIDE THE HEATEDHABITABLE SPACE TO HAVE SEALED JOINTS, CORNERS& BOOTS, AND INSULATED IN ACCORDANCE WITH WSEC2015 EDITION SPECIFICATIONS ("WSEC 2015").
A ONE PERM OR LESS VAPOR RETARDER (IE: KRAFTPAPER, PVA PAINT, ETC.) IS TO BE INSTALLED ON THEWARM SIDE OF ALL INSULATION.
ALL RECESSED LIGHT FIXTURES IN THE THERMALENVELOPE TO BE CERTIFIED UNDER ASTM E-283 ANDSO LABELED, OR SEALED AROUND THE EXTERIOR IN ANAPPROVED MANNER TO BE AIR TIGHT.
ALL WATER PIPES IN UNHEATED SPACES TO BEINSULATED IN ACCORDANCE WITH WSEC 2015.
EXTERIOR DOORS TO BE ADJUSTED SOWEATHER-STRIPPING, THRESHOLD, & DOOR SWEEP AREWORKING PROPERLY & SEAL WELL.
BLOWN-IN ATTIC INSULATION TO BE INSTALLED IN STRICTCONFORMANCE WITH MANUFACTURERSRECOMMENDATIONS FOR DENSITY & COVERAGE.PROVIDE VENT BAFFLES AS REQUIRED & INSULATE &WEATHER-STRIP ATTIC ACCESS DOOR.
PROVIDE MAKEUP AIR WITH FRESH AIR DUCTEDDIRECTLY INTO THE RETURN AIR PLENUM OF THEFURNACE SYSTEM. INSULATE THE DUCT IN ACCORDANCETO WSEC 2015. PROVIDE DAMPER TO REGULATEINCOMING FRESH AIR.
ALL GAS COMBUSTION APPLIANCES, EXCEPT STOVES &CLOTHES DRYERS, TO HAVE COMBUSTION AIR DUCTEDDIRECTLY TO THEM.
ALL COMBUSTION EXHAUSTS TO BE SEPARATED BY AMIN. 3' VERT. & 10' HORIZ.
ENERGY CODE NOTES
WALLS
INSULATION VALUES
ABOVE GRADER-21
BELOW GRADER-21
CEILING
VAULTEDR-38
FLATR-49
FLOOR
CRAWL SPACE*R-30
SLAB ON GRADER-10
ONE OF THE FOLLOWING METHODS WILL BE USED TO MEETTHE REQUIREMENTS OF THE international mechanicalcode (imc) chapter of the 2015 irc:
(A). A SINGLE WHOLE-HOUSE EXHAUST FAN, WHICH CANPERFORM DOUBLE DUTY AS A ROOM SPOT FAN, ISREQUIRED. FAN MUST BE CONTROLLED BY TIMER SET TOOPERATE MIN. OF 8 HOURS PER DAY. THE CFMCAPACITY OF FAN MUST BE 0.25 W.G. AND HAVE MAX.SONE (NOISE) RATING OF 1.5. MIN. SIZE OF FAN MUST BE105 CFM.
(B). FRESH AIR WILL BE CIRCULATED BY THE CENTRALFORCED AIR FURNACE SYSTEM. FURNACE MUST HAVEFRESH AIR INTAKE DUCT AND BLOWER MUST BEACTIVATED BY TIMER TO CIRCULATE DAILY.
WHOLE-HOUSEVENTILATION
* r-30 intended for use with 9 1/2"i-joists. If 11 7/8" i-joists used thenr-38 insulation to be installed.
STAIRS AT FLOOR2
STAIRS AT LANDING1
UNLESS NOTED OTHERWISE, SHEAR WALLS TO BESWP, PRESCRIPTIVE SHEAR WALL. 7/16" OSB OR15/32" PLY ON ONE SIDE OF WALL, UNBLOCKED,WITH 8D NAILS AT 6" O.C. ALONG EDGES, 12" O.C.IN THE FIELD. HOLD DOWNS ARE NOT REQUIRED.
SHEAR WALL 0 PER SHEAR WALL TABLE, S1.7/16" OSB OR 15/32" PLY ON ONE SIDE OF WALL,BLOCKED, WITH 8D NAILS AT 3" O.C. ALONGEDGES, 12" O.C. IN THE FIELD. HOLD DOWNS AREnot REQUIRED.
SWp
sw0
SHEAR WALL PLANSSEE SHEAR WALL TABLE, S1 FOR MORE INFORMATION
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
(5) s
tuds
MIN.
(3) s
tuds
(3) s
tuds
(5) s
tuds
MIN.
bearing wall bearing wall
bearing wall bearing wall bearing wall
BOX IN AS FAUX BEAM
6 x
6 P.T. O
R
CED
AR P
OST
(4) s
tuds
(4) s
tuds
BEARING WALL(EXT. WALL)
brg wall
(3) s
tuds
(3) s
tuds
(3) s
tuds
(3) s
tuds
(3) s
tuds
(3) s
tuds
HIP HIP
RID
GE
valley
HIP
5:12 slope
5:12
slo
pe
5:12 slope
5:12
slo
pe
5:12 slope
11-7/8" TJI 210 FLOOR JOISTS @ 16" O.C.
11-7/8" TJI 210 FLOOR JOISTS @ 16" O.C.
p.t. 2 x 12 deck joists @ 16" O.C.
pre-eng. trusses @ 24" O.C.
pre-eng. trusses @ 24" O.C.
15'-10
1/2
"1'-
6"
6'-2
3/4
"5'-0
"5'-7
1/2"
10'-9 1/4
"10
'-6"
CANTILEVER
line of upper floorwalls: double joistunder wall (typ.)
db
l jo
ist
db
l jo
ist
db
l jo
ist
line of upper floorwalls: double joistunder wall (typ.)
w/ heel
note: post @ beamends is (2) studs typ.
(3) studs min. forspans longer than 6'
covered deck area to getwaterproof membrane
DECK JOISTS SHALL BESLOPED 1/8" - 1/4" PER FOOTFOR DRAINAGE
BRADLEY ENGINEERINGIS NOT RESPONSIBLEFOR WATERPROOFING
ALL HEADERS TO BE 4 X 10 OR6 X 8 DF2 UNLESS NOTED OTHERWISE
NO HEEL FOR MONO TRUSSESOVER TOP OF FLOOR JOISTS
ATTIC SPACE 1
ATTIC SPACE 2
a8
2
a8
1
a8
1
a8
3
16'-9" long 5-1/2" x 15" glb
STEEL BEAM, held up
1-3/4" x 11-7/8" pslor lvl rim joist
10'-5" long 6 x 10 df2 or3-1/2" x 11-7/8" psl, held up
6'-6" long 3-1/2" x11-7/8" psl, held up
7'-9" long 4 x 10 df2
8'-9"
long
6 x
10
df2
12'-9" long 5-1/2" x 12" glbor 5'-1/4" x 11'-7/8" psl
16'-4" long 5-1/2" x 12" glb or5'-1/4" x 11'-7/8" psl, held up.see detail 'c', s1
8'-9"
long
6 x
10
d
f2
16'-0" long 5-1/2" x 15" glbor 7" x 11-7/8" psl, held up
11' long 6 x 10 df2
provide solid blockingunder exterior wall
connect mono truss towall per detail 'f', s1
see post to beamconnection detail 'd', s1
16'-4" long 6 x 12 p.t. or 5-1/2" x 10-1/2"rosboro treated 'x-beam'
FLOOR JOIST
BEAM/HEADER
OUTLINE of walls of FLOORBENEATH
OUTLINE OF SUPPORTEDFLOOR/EXTENTS OF FLOOR JOISTS
BEARING WALL
LINE OF ROOF/EXTENTS OF UPPERFLOOR LIVING SPACE
OUTLINE OF UPPER FLOOR WALLS
JOIST HANGER
POST
FLOOR & ROOF FRAMINGLEGEND
1'-6"
insulation baffle W/1" min. air space
5
12
7/16" cdx or osb SHEATHING
composite ROOFING
pre-eng. roof trussesw/ heel @ 24" o.c.
1/2" GWB
R-21 INSULATION
siding per elevations
7/16" cdx or osb SHEATHING
2 X 4 OR 2 X 6
CONT. SOFFIT VENT
CONT. METAL GUTTER
5/4 X 6 FASCIA
CONNECT WALL TO ROOFPER DETAIL 'E', S2
note: heel height to matchheight of upper floor joistsplus subfloor
R-49 INSULATION
hurricane tie @ ea. truss
1/2" GWBSOFFIT BOARD or t&g decking
1'-6"
insulation baffle W/1" min. air space
5
12
7/16" cdx or osb SHEATHING
composite ROOFING
pre-eng. roof trusses
1/2" GWB
R-21 INSULATION
siding per elevations
7/16" cdx or osb SHEATHING
2 X 4 OR 2 X 6
CONT. SOFFIT VENT
CONT. METAL GUTTER
5/4 X 6 FASCIA
hurricane tie @ ea. truss
1/2" GWB
R-49 INSULATION
floor joists
3/4" t&g plywood orosb subfloor
SOFFIT BOARD or t&g decking
connect trussto wall perdetail 'f', s1
JOISTS PER PLAN
r-21 insulation
1/2" gwb
3/4" t&g PLYWOOD OROSB SUBFLOOR
CONT. RIM JOIST
1/2" gwb
1/2" gwb
R-21 INSULATION
2 X 6 FRAMING
SIDING PER ELEVATIONS
7/16" cdx or osb SHEATHING
see floor to floorconnection detail 'b', s1
A8
FLOOR FRAMINGNOTES
LO
WE
R R
OO
F F
RA
MIN
G &
UP
PE
R F
LO
OR
FR
AM
ING
PLA
N &
DE
TA
ILS
LOWER ROOF FRAMING &UPPER FLOOR FRAMING PLAN
NOTE: ROOF TRUSSES AND FLOOR JOISTS SHOWN INDRAWING ARE FOR SCHEMATIC PURPOSES ONLY.FOR TRUSS PLACEMENT, DESIGN AND ENGINEERINGREFER TO TRUSS DESIGN & SPECIFICATIONS FROMTRUSS SUPPLY COMPANY. FOR FLOOR JOISTLAYOUT REFER TO JOIST DESIGN & SPECIFICATIONSFROM FLOOR JOIST SUPPLIER.
WRITTEN DIMENSIONS TAKE PRECEDENCE OVERSCALED DIMENSIONS. VERIFY ALL DIMENSIONS ANDCONDITIONS IN THE FIELD.
ENGINEERING SPECIFICATIONS, NOTES ANDDRAWINGS ACCOMPANIED WITH PLANS TOSUPERCEDE ALL INFORMATION ON ARCHITECTURALDRAWINGS. FOR ANY DISCREPANCIES BETWEENENGINEERING AND ARCHITECTURAL DRAWINGSREFER TO ENGINEERING.
REFER TO FLOOR FRAMING PLAN FROM FLOORJOIST MANUFACTURER/SUPPLIER. FLOOR JOISTMANUFACTURER/SUPPLIER SHALL PROVIDE ANDSUBMIT ENGINEERED DESIGN TO THE BUILDINGDEPARTMENT FOR APPROVAL PRIOR TOFABRICATION AND INSTALLATION.
PROVIDE TEMPORARY BRACING AS REQUIREDUNTIL ALL PERMANENT CONNECTIONS ANDSTIFFENERS HAVE BEEN INSTALLED.
FOR FLOOR SHEATHING USE 3/4" CDX OR OSBSTURDI-FLOOR T&G, GLUE AND NAIL W/ RING SHANK8d's @ 6" EDGES & 12" IN FIELD U.N.O. FACE GRAINPERPENDICULAR TO SUPPORTS.
PROVIDE BLOCKING BETWEEN I-JOISTS AT INTERIORBEARING LOCATIONS WHERE THERE IS A LOADBEARING WALL ABOVE.
PROVIDE TIMBERSTRAND RIMS WHERE FLOORJOISTS BEAR AT EXTERIOR WALLS.
ALL EXTERIOR WALLS ASSUMED TO BE BEARING.
ALL BEAMS AND HEADERS TO BE 4 x 10 DF #2 OR6 X 8 DF #2 U.N.O.
JOIST HANGERS & CONNECTIONS TO BE 'SIMPSON'U.N.O.
ALL CONNECTORS AND FASTENERS IN CONTACT WITHPRESSURE TREATED WOOD SHALL BE HOT DIPPEDGALVANIZED OR EQUIVALENT PROTECTION.
ROOF NOTES TRUSSES TO BE SPACED AT 24" O.C. UNLESS NOTED
OTHERWISE.
ROOF PITCH IS TO BE 5:12 ON WEST SIDE OF HOUSE,3.5:12 ON EAST SIDE.
ROOFING MATERIAL IS COMPOSITE.
OVERHANGS ARE 18" WITH CONTINUOUS METALGUTTER THROUGHOUT.
FASCIA SHALL BE 5/4 x 6 WITH CONTINUOUS METALGUTTER.
ALL BEAMS & HEADERS TO BE 4 X 10 DF #2 OR6 x 8 DF #2 UNO.
PROVIDE SOLID BLOCKING OVER SUPPORTS.
TRUSSES/RAFTERS TO BE SHEATHED WITH 7/16" cdxOR osb SHEATHING WITH 15# FELT OR BETTER. USEPLYWOOD SHEATHING ON ALL SOFFITED AREAS.
PROVIDE ROOF CROSS VENTILATION FOR EACHSEPARATE SPACE WHERE APPLICABLE.
TRUSS NOTES TRUSS MANUFACTURER SHALL PROVIDE DESIGN
DETAILS AND ENGINEERING FOR ALL TRUSSES. COPYTO BE AVAILABLE ON SITE FOR FRAMINGINSPECTIONS.
ALL TRUSSES SHALL CARRY THE MANUFACTURER'SSTAMP.
ALL TRUSSES SHALL BE STORED, INSTALLED &BRACED PER MANUFACTURER'S SPECIFICATIONS.
TRUSSES SHALL NOT BE ALTERED IN THE FIELDWITHOUT THE APPROVAL OF THE BUILDING OFFICIALAND/OR APPROVED ENGINEERING CALCULATIONSPROVIDED BY THE TRUSS MANUFACTURER.
ROOF TRUSSES TO BE SHEATHED WITH 7/16" cdx orosb SHEATHING WITH 15# FELT or better. USEPLYWOOD SHEATHING ON ALL SOFFITED AREAS.
PROVIDE ROOF CROSS VENTILATION FOR EACHSEPARATE SPACE where applicable..
ATTIC VENTILATIONATTIC VENTILATION REQUIRED. REFER TO IRC R806.1AND R806.2.
SQUARE FOOTAGE OF ATTIC SPACE FOR 'ATTIC SPACE1' = 172 S.F.
172/300 = 0.57 S.F. NET VENT AREA REQUIRED.
SQUARE FOOTAGE OF ATTIC SPACE FOR 'ATTIC SPACE2' = 62 S.F.
62/300 = 0.2 S.F. NET VENT AREA REQUIRED.
PROVIDE MIN. 1/150 OF ATTIC AREA, OR 1/300 IF HALF ISAT EAVE AND REMAINDER AT MIN. 3' ABOVE PLATELINE. OPENINGS TO BE COVERED WITH 1/8" CORROSIONRESISTANT METAL MESH OR EQUAL. EAVE OR CORNICEVENT SHALL NOT BE BLOCKED. MAINTAIN MIN. 1" AIRSPACE BETWEEN INSULATION AND ROOF SHEATHING ATTHE LOCATION OF THE VENT.
for open eave soffit use bird block trussblocking, with (3) 1 1/2" dia. holes and mesh screencovering the holes, between each truss.
for closed eave soffit use continuous soffitventing.
TRUSS/EAVE DETAIL1
TRUSS/EAVE DETAIL2
TYP. WALL DETAIL3
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
SCISSOR TRUSSAREA
SCISSOR TRUSSAREA
LINE OF FLOOR BELOW
LINE OF FLOOR BELOW
6 x
6 pos
t
6 x
6 pos
t
RID
GE
RID
GE
RID
GE
RID
GE
HIP
HIP
VALLEY
HIP
HIP
HIPV
ALLEY
VA
LLEYHIP
HIP
HIP
HIP
HIP
5:12
slo
pe
pre-eng. trusses @ 24" O.C.
5:12 slope
5:12
slo
pe
5:12
slo
pe
5:12
slo
pe
5:12 slope
5:12 slope
5:12
slo
pe
5:12 slope
1'-6"
1'-6"
TYP.OVERHANGS
ALL HEADERS TO BE 4 X 10 OR6 X 8 DF2 UNLESS NOTED OTHERWISE
a9
2
a9
1
a9
2
a9
1
a9
3
a9
1
connect porch headerto 6 x 6 cedar or p.t.post with simpson lce4,cbt4z, or euquiv.
connect porch headerto 6 x 6 cedar or p.t.post with simpson lce4,cbt4z, or euquiv.
depending on the location ofgirder truss, this beam maynot be required. if g.t. bearson beam, use 6 x 12 df2 or 5-1/2"x 10-1/2" glb to match otherporch header
16'-6" long 6 x 12 df2or 5-1/2" x 10-1/2" glb
8'-9" long 6 x 10 df2
double studmullions
double studmullions
11' long 6 x 10 df2
note: post @ beamends is (2) studs typ.
(3) studs min. forspans longer than 6'
OUTLINE OF ROOF
HIDDEN LINE OF ROOF
BEAM/HEADER
OUTLINE OF WALLS BENEATH
VAULTED OR HIGHER CEILING AREA
POST
ROOF FRAMING LEGEND
1'-6"
R-49 INSULATION
insulation baffle W/1" min. air space
5
12
7/16" cdx or osb SHEATHING
composite ROOFING
pre-eng. roof trusses@ 24" o.c.
hurricane tie @ ea. truss
1/2" GWB
2 X 6 FRAMING TYP.
1/2" GWB
R-21 INSULATION
siding per elevations
7/16" cdx or osb SHEATHING
2 X 4 OR 2 X 6
CONT. SOFFIT VENT
CONT. METAL GUTTER
5/4 X 6 FASCIA
CONNECT WALL TO ROOFPER DETAIL 'E', S2
SOFFIT BOARD or t&g decking
1'-6"
R-49 INSULATION
insulation baffle W/1" min. air space
5
12
7/16" cdx or osb SHEATHING
composite ROOFING
pre-eng. roof trusses@ 24" o.c.
hurricane tie @ ea. truss
1/2" GWB
2 X 6 FRAMING TYP.
1/2" GWB
R-21 INSULATION
siding per elevations
7/16" cdx or osb SHEATHING
2 X 4 OR 2 X 6
CONT. SOFFIT VENT
CONT. METAL GUTTER
5/4 X 6 FASCIA
CONNECT WALL TO ROOFPER DETAIL 'E', S2
SOFFIT BOARD or t&g decking
1'-6"
insulation baffle W/1" min. air space
5
12
7/16" cdx or osb SHEATHING
composite ROOFING
pre-eng. roof trusses@ 24" o.c.
hurricane tie @ ea. truss
SOFFIT BOARD or t&g decking
2 X 4 OR 2 X 6
CONT. SOFFIT VENT
CONT. METAL GUTTER
5/4 X 6 FASCIA
CONNECT WALL TO ROOFPER DETAIL 'E', S2
beam per plan
SOFFIT BOARD or t&g decking
frame down to match heightof closed eave soffit
1x wrap
A9
UP
PE
R R
OO
FFR
AM
ING
PLA
N &
DE
TA
ILS
TRUSS/EAVE DETAIL1
SCISSOR TRUSS/EAVE DETAIL2
NOTE: ROOF TRUSSES AND FLOOR JOISTS SHOWN INDRAWING ARE FOR SCHEMATIC PURPOSES ONLY.FOR TRUSS PLACEMENT, DESIGN AND ENGINEERINGREFER TO TRUSS DESIGN & SPECIFICATIONS FROMTRUSS SUPPLY COMPANY. FOR FLOOR JOISTLAYOUT REFER TO JOIST DESIGN & SPECIFICATIONSFROM FLOOR JOIST SUPPLIER.
ROOF NOTES TRUSSES TO BE SPACED AT 24" O.C. UNLESS NOTED
OTHERWISE.
ROOF PITCH IS TO BE 5:12.
ROOFING MATERIAL IS COMPOSITE.
OVERHANGS ARE 18" WITH CONTINUOUS METALGUTTER THROUGHOUT.
FASCIA SHALL BE 5/4 x 6 WITH CONTINUOUS METALGUTTER.
ALL BEAMS & HEADERS TO BE 4 X 10 DF #2 OR6 x 8 DF #2 UNO.
PROVIDE SOLID BLOCKING OVER SUPPORTS.
TRUSSES/RAFTERS TO BE SHEATHED WITH 7/16" cdxOR osb SHEATHING WITH 15# FELT OR BETTER. USEPLYWOOD SHEATHING ON ALL SOFFITED AREAS.
PROVIDE ROOF CROSS VENTILATION FOR EACHSEPARATE SPACE WHERE APPLICABLE.
TRUSS NOTES TRUSS MANUFACTURER SHALL PROVIDE DESIGN
DETAILS AND ENGINEERING FOR ALL TRUSSES. COPYTO BE AVAILABLE ON SITE FOR FRAMINGINSPECTIONS.
ALL TRUSSES SHALL CARRY THE MANUFACTURER'SSTAMP.
ALL TRUSSES SHALL BE STORED, INSTALLED &BRACED PER MANUFACTURER'S SPECIFICATIONS.
TRUSSES SHALL NOT BE ALTERED IN THE FIELDWITHOUT THE APPROVAL OF THE BUILDING OFFICIALAND/OR APPROVED ENGINEERING CALCULATIONSPROVIDED BY THE TRUSS MANUFACTURER.
ROOF TRUSSES TO BE SHEATHED WITH 7/16" cdx orosb SHEATHING WITH 15# FELT or better. USEPLYWOOD SHEATHING ON ALL SOFFITED AREAS.
PROVIDE ROOF CROSS VENTILATION FOR EACHSEPARATE SPACE where applicable..
ATTIC VENTILATIONATTIC VENTILATION REQUIRED. REFER TO IRC R806.1AND R806.2.
SQUARE FOOTAGE OF ATTIC SPACE = 1636 S.F.
1636/300 = 5.45 S.F. NET VENT AREA REQUIRED.
PROVIDE MIN. 1/150 OF ATTIC AREA, OR 1/300 IF HALF ISAT EAVE AND REMAINDER AT MIN. 3' ABOVE PLATELINE. OPENINGS TO BE COVERED WITH 1/8" CORROSIONRESISTANT METAL MESH OR EQUAL. EAVE OR CORNICEVENT SHALL NOT BE BLOCKED. MAINTAIN MIN. 1" AIRSPACE BETWEEN INSULATION AND ROOF SHEATHING ATTHE LOCATION OF THE VENT.
for open eave soffit use bird block trussblocking, with (3) 1 1/2" dia. holes and mesh screencovering the holes, between each truss.
for closed eave soffit use continuous soffitventing.
TRUSS/EAVE DETAIL3
UPPER ROOF FRAMING PLAN
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
TOP OF SLAB
TOP OF subfloor
TOP OF plate
TOP OF plate
9'-1 1/8"
9'-1 1/8"
12
5
8'-0
"
9'-1 1/8"
8'-0
"
9'-1 1/8"
26'-3 1/2
"
high pt. of roof
top of plate
top of windows
top of plate
top of windows
top of subfloor
top of slab
1'-6"
R-21 INSULATION
PRE-ENG. TRUSSES @ 24" O.C.
R-49 INSULATION
R-21 INSULATION
3/4" t&g plywood orosb subfloor
(LIVING ROOM BEYOND)
r-21 insulation
scissor truss area
3'-0
"
GUARDRAIL
r-10 insulation
GRADE
r-49 insulation
12
5
WATERPROOF MEMBRANE
P.T. 2 x 12 JOISTS @ 16" O.C.RIPPED FOR SLOPE
frame down to match heightof closed eave soffit
1'-6"
1'-6"
open guardrails shallhave intermediate railssuch that a 4" dia. spherecannot pass through atany point
5/8" type 'x' gwb
1/2" min. gwb
R-38 INSULATION
R-21 INSULATION
R-38 INSULATION
PRE-ENG. TRUSSES @ 24" O.C.
see deck ledgerdetail 'c', s1
scissor truss area
R-21 INSULATION
pre-eng. mono trussesW/ HEEL @ 24" o.c.
1'-6"
1'-6"
R-21 INSULATION
R-49 INSULATION
pre-eng. mono trusses@ 24" o.c.
R-49 INSULATION
R-21 INSULATION
R-21 INSULATION
R-10 INSULATION
12
5
R-49 INSULATION
connect truss towall per detail 'f', s1
A10
BU
ILD
ING
SE
CTIO
NS
BUILDING SECTION B - B
BUILDING SECTION A - A
BUILDING SECTION C - C
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
16' w x 8' h o.h. door
2650pic
2650pic
2640pic2650
pictyp.
2650pictyp.
TOP OF SLAB
TOP OF subfloor
TOP OF plate
TOP OF plate
9'-1 1/8"
9'-1 1/8"
cont. 5/4 x trim
5/4 x 6 fascia w/ cont.metal gutter
1'-6" x 1'-6" tiles
composite roofing
12
5
CORRUGATED METALSIDING
1'-6" x 1'-6" tiles
fiber cement panels
8'-0
"
9'-1 1/8"
8'-0
"
9'-1 1/8"
26'-3 1/2
"
high pt. of roof
top of plate
top of windows
top of plate
top of windows
top of subfloor
top of slab
1'-6"
4020 pic
8010 pic
4020 pic2020pic
60
20 c
sm
t
60
20 c
sm
t 6050 sl 2040csmt
12
5
12
5
GUARDRAIL
3'-0
"
CORRUGATED METALSIDING
composite roofing
1'-6" x 1'-6" tiles
CORRUGATED METALSIDING
1'-6" x 1'-6" tiles
fiber cement panels
TOP OF SLAB
TOP OF subfloor
TOP OF plate
TOP OF plate
9'-1 1/8"
9'-1 1/8"
26'-9 1/2
"
average grade
8080 sl dr
A11
ELE
VA
TIO
NS
NO
RTH
& E
AS
T
NORTH ELEVATION
EAST ELEVATION
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC
5040sl
12080sl dr
8080sl dr
5060 pic 5060 pic
TOP OF SLAB
TOP OF subfloor
TOP OF plate
TOP OF plate
9'-1 1/8"
9'-1 1/8"
12
5
fiber cement panels
composite roofing
3' tall guardrailcable railing
top of slab
top of sliders/windows
top of sliders/windows
top of subfloor
8'-0
"8'-0
"
26'-3 1/2
"
high pt. of roof
open guardrails shallhave intermediate railssuch that a 4" dia. spherecannot pass through atany point
see post to beamconnection perdetail 'd', s1
6050 sl 2040csmt
2620awn
2640pic
6020 awn
3' tall half-wall
CORRUGATED METALSIDING
fiber cement panels
12
5
composite roofing
TOP OF SLAB
TOP OF subfloor
TOP OF plate
TOP OF plate
high pt. of roof
26'-9 1/2
"
average grade
9'-1 1/8"
9'-1 1/8"
1'-6"
1'-6"
2620awn
composite roofing
6'-0
"2'-0
"
4'-0"
typ. panelsizes
CORRUGATED METALSIDING
A12
ELE
VA
TIO
NS
SO
UTH
& W
ES
T
SOUTH ELEVATION
WEST ELEVATION
UNIT 6BUCKLEY
DO
E R
UN
AT S
UN
SE
T C
OV
E E
STA
TE
S,
LLC