controlling & switching

of 219 /219
1.1 SG10911 Load circuit breaker with isolating function Highly wear resistant contacts • Quick make • Terminal capacity 50 mm 2 • Compatible busbars 1-, 2-, 3-, 4-pole Description Controlling & Switching Main Load Disconnector Switch (Isolator) HIS xPole Home

Upload: khangminh22

Post on 23-Feb-2023

4 views

Category:

Documents


0 download

Embed Size (px)

TRANSCRIPT

1.1

SG10911

• Load circuit breaker with isolating function

• Highly wear resistant contacts

• Quick make

• Terminal capacity 50 mm2

• Compatible busbars

• 1-, 2-, 3-, 4-pole

Description

Controlling & SwitchingMain Load Disconnector Switch (Isolator) HIS

xPole Home

1.2Controlling & Switching

Main Load Disconnector Switch (Isolator) HIS

SG10611 20 1 HIS-20/1 167342 12/12020 2 HIS-20/2 167343 1/6020 3 HIS-20/3 167344 1/4020 4 HIS-20/4 167345 1/3025 1 HIS-25/1 167346 12/12025 2 HIS-25/2 167347 1/6025 3 HIS-25/3 167348 1/4025 4 HIS-25/4 167349 1/3032 1 HIS-32/1 167350 12/12032 2 HIS-32/2 167351 1/6032 3 HIS-32/3 167352 1/4032 4 HIS-32/4 167353 1/3040 1 HIS-40/1 142816 12/12040 2 HIS-40/2 142817 1/6040 3 HIS-40/3 142818 1/4040 4 HIS-40/4 142819 1/3063 1 HIS-63/1 142820 12/12063 2 HIS-63/2 142821 1/6063 3 HIS-63/3 142822 1/4063 4 HIS-63/4 142823 1/3080 1 HIS-80/1 142824 12/12080 2 HIS-80/2 142825 1/6080 3 HIS-80/3 142826 1/4080 4 HIS-80/4 142827 1/30100 1 HIS-100/1 142828 12/120100 2 HIS-100/2 142829 1/60100 3 HIS-100/3 142830 1/40100 4 HIS-100/4 142831 1/30125 1 HIS-125/1 142832 12/120125 2 HIS-125/2 142833 1/60125 3 HIS-125/3 142834 1/40125 4 HIS-125/4 142835 1/30

Rated Current (A) Number of Poles Type Article No. Units perDesignation package

SG10711

SG10811

SG10911

Accessories

Switching interlock IS/SPE-1TE• Without lock• Also suitable for PFIM, CFI6, PKNM, CKN6

SG47812

Description Type Article No. Units perDesignation package

sg01215 Terminal cover Z-IS/AK-1TE 276290 10/600

Terminal Cover Caps Z-IS/AK-1TE• Can be sealed with leads• Modular design, width 1 MU

PHASE OUT Switching interlock without lock for Isolators, RCDs, combined RCD/MCBs, ...

IS/SPE-1TE 101911 5/30

xPole Home

1.3Controlling & SwitchingMain Load Disconnector Switch (Isolator) HIS

Description

• Load circuit breaker with isolating function• Design according to IEC/EN 60947-3• Highly wear resistant contacts• Quick make, black toggle• Terminal capacity 50 mm2

• Compatible busbars with switchgear series Xpole by use of the mouth terminal in combination with standard fork busbar

Technical DataIS-20 IS-25 IS-32 IS-40 IS-63 IS-80 IS-100 IS-125

ElectricalDesign according to IEC/EN 60947-3Rated voltage 240/415 VFrequency 50/60 HzRated insulation voltage Ui 690 V~Rated impulse withstand voltage Uimp 6 kVPollution degree 3Rated short-time withstand current Icw 2 kARated short-circuit making capacity Icm 2.8 kARated current 240/415V, AC23A 20 A 25 A 32 A 40 A 63 A 80 A 100 A 125 ANumber of poles 1-, 2-, 3-, 4-polesMaximum back-up fuse 125 A gGShort circuit strength - with back-up fuse according to IEC/EN 60947-3 12.5 kA 12.5 kA 12.5 kA 12.5 kA 12.5 kA 12.5 kA 10 kA 10 kAEndurance

Electrical components operation cycles 3,000 3,000 3,000 3,000 3,000 3,000 3,000 2.000Mechanical components operation cycles 16,000 16,000 16,000 16,000 16,000 16,000 16,000 14.000

MechanicalFrame size 45 mmDevice height 80 mmDevice width 17.5 mm/PolMounting quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protection, built-in IP40Terminal protection fi nger and hand touch safe according to BGV A3Terminals top and bottom open mouthed/lift terminalsTerminal capacity 2.5 - 50 mm2

Busbar thickness 0.8 - 2 mmFastening torque of terminal screws 2.5 - 5 NmFunction irrespective of the position of installation

Connection diagram1-pole 2-poles 3-poles 4-poles

Dimensions (mm)

Switching inter-lockIS/SPE1TE

Terminal coverZ-IS/AK-1TE

xPole Home

1.4Controlling & Switching

Main Load Disconnector Switch (Isolator) HIS

Derating table for Main Load Disconnector Switch (Isolator) HIS above 2000m sea level60947-3

Un 240/415

Above sea level(m)

Overvoltagecategory

Disconnectfunction

Un Ui Uimp I/In

m x x V V kV x

<=2000 III yes 240/415 690 6 1

>2000-2500 III yes 240/415 415 4 0.93

>2500-3000 III yes 240/415 415 4 0.88

>3000-3500 III yes 240/415 415 4 0.83

>3500-4000 III yes 240/415 415 4 0.78

xPole Home

1.5

5 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & Switching

SG10611

– Switches

– Installation Contactors

– Relays

– Signalling Devices

– Transformers

Description

SG83911

SG82911

1.6Controlling & Switching

Main Load Disconnector Switch (Isolator) IS

6 EATON CORPORATION xxxxx+xxxx-xxxxEN

Main Load Disconnector Switch (Isolator) IS

Rated current (A)

Poles TypeDesignation

Article No. Units perpackage

SG10611 16 1 IS-16/1 276254 12/12016 2 IS-16/2 276255 1/6016 3 IS-16/3 276256 1/4016 4 IS-16/4 276257 1/3020 1 IS-20/1 276258 12/12020 2 IS-20/2 276259 1/6020 3 IS-20/3 276260 1/4020 4 IS-20/4 276261 1/3025 1 IS-25/1 276262 12/12025 2 IS-25/2 276263 1/6025 3 IS-25/3 276264 1/4025 4 IS-25/4 276265 1/3032 1 IS-32/1 276266 12/12032 2 IS-32/2 276267 1/6032 3 IS-32/3 276268 1/4032 4 IS-32/4 276269 1/3040 1 IS-40/1 276270 12/12040 2 IS-40/2 276271 1/6040 3 IS-40/3 276272 1/4040 4 IS-40/4 276273 1/3063 1 IS-63/1 276274 12/12063 2 IS-63/2 276275 1/6063 3 IS-63/3 276276 1/4063 4 IS-63/4 276277 1/3080 1 IS-80/1 276278 12/12080 2 IS-80/2 276279 1/6080 3 IS-80/3 276280 1/4080 4 IS-80/4 276281 1/30100 1 IS-100/1 276282 12/120100 2 IS-100/2 276283 1/60100 3 IS-100/3 276284 1/40100 4 IS-100/4 276285 1/30125 1 IS-125/1 276286 12/120125 2 IS-125/2 276287 1/60125 3 IS-125/3 276288 1/40125 4 IS-125/4 276289 1/30

SG10711

SG10811

SG10911

Accessories

Switching interlock IS/SPE-1MU• Without lock• Also suitable for PFIM, CFI6, PKNM, CKN6

SG47812 Switching interlock without lock for Isolators, RCDs, combined RCD/MCBs, ...

IS/SPE-1MU 101911 5/30

Description TypeDesignation

Article No. Units perpackage

sg01215 Terminal cover Z-IS/AK-1MU 276290 10/600

Terminal cover Z-IS/AK-1MU• Can be sealed with leads• Modular design, width 1 MU

PHASE OUT

1.7

7 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingMain Load Disconnector Switch (Isolator) IS

Description Main Load Disconnector Switch (Isolator) IS

• Load circuit breaker with isolating function• Design according to IEC/EN 60947-3• Highly wear resistant contacts• Quick make, black toggle• Terminal capacity 50 mm2

• Compatible busbars with switchgear series Xpole by use of the mouth terminal in combination with standard fork busbar

Technical DataIS-16 IS-20 IS-25 IS-32 IS-40 IS-63 IS-80 IS-100 IS-125

ElectricalDesign according to IEC/EN 60947-3Rated voltage 240/415 VFrequency 50/60 HzRated insulation voltage Ui 690 V~Rated peak withstand voltage Uimp 6 kVPollution degree 3Rated short-time withstand current Icw 2 kARated short-circuit making capacity Icm 2.8 kARated current 240/415 V, AC23A 16 A 20 A 25 A 32 A 40 A 63 A 80 A 100 A 125 ANumber of poles 1-, 2-, 3-, 4-poleMaximum back-up fuse 125 A gGShort-circuit current strength - with back-up fuse according to IEC/EN 60947-3 12.5 kA 12.5 kA 12.5 kA 12.5 kA 12.5 kA 12.5 kA 12.5 kA 10 kA 10 kAEndurance

operating cycles electrical components 3,000 3,000 3,000 3,000 3,000 3,000 3,000 3,000 2,000operating cycles mechanical components 16,000 16,000 16,000 16,000 16,000 16,000 16,000 16,000 14.000

MechanicalFrame size 45 mmDevice height 80 mmDevice width 17.5mm/poleMounting quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protection, built-in IP40Terminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Upper and lower terminals Twin-purpose terminalsTerminal capacity 2.5 - 50 mm2

Busbar thickness 0.8 - 2 mmTightening torque of terminal screws 2.5 - 5 NmFunction irrespective of the position of installation

Connection diagram1-pole 2-pole 3-pole 4-pole

Dimensions (mm)

Anti-tamper deviceIS/SPE1MU

Terminal coverZ-IS/AK-1MU

1.8Controlling & Switching

Circuit Breaker ZP-A

8 EATON CORPORATION xxxxx+xxxx-xxxxEN

Circuit Breaker ZP-A

Poles Rated current (A)

TypeDesignation

Article No. Units perpackage

SG00912 1 40 ZP-A40/1 248263 12 / 1202 40 ZP-A40/2 248264 1 / 603 40 ZP-A40/3 248265 1 / 403+N 40 ZP-A40/3N 248266 1 / 301 63 ZP-A63/1 284906 12 / 1202 63 ZP-A63/2 284907 1 / 603 63 ZP-A63/3 284908 1 / 403+N 63 ZP-A63/3N 284909 1 / 30

Accessories:Auxiliary switch for subsequent installation ZP-IHK 286052

ZP-WHK 286053Tripping signal contact for subsequent installation ZP-NHK 248437Shunt trip release ZP-ASA/.. 248438, 248439Undervoltage release Z-USA/.. 248288-248291Additional terminal 35 mm2 Z-HA-EK/35 263960Anti-tamper device Z-IS/SPE-1MU 274418

Description Circuit Breaker ZP-A

• Design according to IEC/EN 60947-1, -3• Poles: 1, 2, 3, 3N• Rated current: 40 A, 63 A• Accessories for switchgear also for ZP-A usable!

Technical DataZP-A

ElectricalRated operational voltage Ue 230/400 V ACRated frequency 50 HzRated insulation voltage UI 440 V ACRated peak withstand voltage (1.2/50 μS) Uimp 4 kVConventional thermal current Ith

ZP-A40 40 AZP-A63 63 A

Utilisation category AC22AMinimum voltage per contact IeZP-A40 40 A ACZP-A63 63 A AC

Utilisation category AC23AMinimum voltage per contact Ie 16 A AC

Short-circuit current strength with back-up fuse 40 A gG 3 kA (U = 240 V, cos = 0.87)Endurance

electrical components 8,000 switching operationsmechanical components 20,000 switching operations

MechanicalFrame size 45 mmDevice height 80 mmDevice width 17.5mm/poleMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP40Terminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Upper and lower terminals lift terminals + guide for secure terminalTerminal capacity 1.5-25 mm2

Terminal screws M5 (Pozidrive) Z2Tightening torque of terminal screws max. 2.4 Nm

1.9

9 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingCircuit Breaker ZP-A

Connection diagram1pole 2pole 3pole 3+Npole

Dimensions (mm)

Practical Hint Practical Hint

e.g. 16(2)A .... Ratings for resistive/inductive consumers

ÖVE-SN45, § 305

....... Ratings for incandescent lamp load (AC 5b IEC 60947-4)

ÖVE-SN45, § 207, IEC 60947-3

Switching contactin general

Switch with reduced air gap

Power circuit breaker

Disconnector

Load disconnector switch

Fuse power circuit breaker

Fuse disconnector

Fuse switch disconnector

1.10Controlling & Switching

MCB for Auxiliary Switch Circuits PLSM-B4/.-HS, CLS6-B4/..-HS

10 EATON CORPORATION xxxxx+xxxx-xxxxEN

MCB for Auxiliary Switch Circuits PLSM-B4/.-HS, CLS6-B4/..-HS

Poles Rated Breaking Capacity(kA)

TypeDesignation

Article No. Units perpackage

SG54312 1 10 PLSM-B4-HS 247221 2 / 1201+N 10 PLSM-B4/1N-HS 236722 2 / 802 10 PLSM-B4/2-HS 247222 1 / 601 6 CLS6-B4-HS 247969 2 / 1202 6 CLS6-B4/2-HS 247971 1 / 60

Description MCB for Auxiliary Switch Circuits PLSM-B4/.-HS, CLS6-B4/..-HS

• Design according to EN 60898-1, 4 A, Characteristic B• Very low let-through energy in order to prevent contact welding in auxiliary swit ches of any and all switchgear, as well as thermostats control devices, timers, etc.• Busbar connection to CLS6, PFIM, PKN, ...

Technical DataPLSM-B4/.-HS CLS6-B4/..-HS

ElectricalNumber of poles 1-, 1+N-, 2pole 1-, 2poleRated voltage 230/400 V 230/400 VFrequency 50/60 Hz 50/60 HzRated current 4 A 4 ARated breaking capacity 10 kA 6 kAMechanicalFrame size 45 mm 45 mmDevice height 80 mm 80 mmDevice width 17.5 mm (1MU) / 26.3 mm / 35 mm (2MU) 17.5 mm (1MU) / 35 mm (2MU)Mounting quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protection, built-in IP40 IP40Terminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Terminals Twin-purpose terminals Twin-purpose terminalsTerminal capacity 1-25 mm2 1-25 mm2

Terminal screws M3 (Pozidrive) M3 (Pozidrive)Tightening torque of terminal screws 0.8-1.0 Nm 0.8-1.0 NmBusbar thickness 0.8 - 2 mm 0.8 - 2 mm

Connection diagrame.g. 1pole

Dimensions (mm)PLSM-B4/.-HS CLS6-B4/..-HS

1.11

11 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingMCB for Auxiliary Switch Circuits PLSM-B4/.-HS, CLS6-B4/..-HS

Even auxiliary switches must be predected against overload and short circuit by means of suitable back-up fuses according to manufacturer specifi cation. According to IEC 60947-5 a maximum back-up fuse is specifi ed for conditional short circuit prevention up to 1,000 A. Therefore, connection of the auxiliary switch to the nearest MCB is not permitted. Danger of contact welding! The MCB for auxiliary switch circuits ...-HS offers a simple solution.

Practical HintLet-through Energy PLSM-B4-HS

Let-through Energy PLSM-B4-HS, Characteristic B, 1pole

Prospective short-circuit current [A]

Let

thro

ugh

ener

gy I2

t [A

2 se

c]

1.12Controlling & Switching

Pushbutton Z-T/; Control Switch Z-S../; Changeover Switch Z-S/.W

12 EATON CORPORATION xxxxx+xxxx-xxxxEN

Pushbutton Z-T/

Colour Pushbutton/Function TypeDesignation

Article No. Units perpackage

SG37112 green 4NO Z-T/4S-G 248328 12 / 120black 3NO+1NC Z-T/3S1O 248330 12 / 120

Control Switch Z-S../

Rated current(A)

Function TypeDesignation

Article No. Units perpackage

SG38912 16 3NO Z-S/3S 248334 12 / 12016 4NO Z-S/4S 248335 12 / 12016 2NO+2NC Z-S/SSOO 248337 12 / 12016 3NO+1NC Z-S/3S1O 248338 12 / 120

Changeover Switch Z-S/.W

Function TypeDesignation

Article No. Units perpackage

SG39012 1CO I-0-II Z-S/WM 248345 12 / 1202CO I-0-II Z-S/2WM 248346 12 / 1201CO DAY-0-NIGHT Z-S/WTN 248347 12 / 1202CO DAY-0-NIGHT Z-S/2WTN 248348 12 / 120

1.13

13 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingPushbutton Z-T/; Control Switch Z-S../; Changeover Switch Z-S/.W

Description Pushbutton Z-T/; Control Switch Z-S../; Changeover Switch Z-S/.W

• Design according to IEC 60669, VDE 0632• Types Z-S/WM and /2WM with central position (0-position)• Types Z-S/WTN and -2WTN with TAG-0-NACHT (DAY-0-NIGHT) printed onto the device

Technical DataZ-T/ Z-S../ Z-S/.W

ElectricalRated voltage 230 V AC 240 V AC 240 V ACFrequency 50 HZ 50 HZ 50 HZRated current 16 A / 230 V~ 20 A / 240 V~ 20 A / 240 V~Switching capacity – 1.25 x In; 1.1 x Un 1.25 x In; 1.1 x Un

Short-circuit current strength 10 kA 10 kA 10 kAMechanicalSwitching toggle – black blackPushbutton colour green - NO – –

black - NO/NCFrame size 45 mm 45 mm 45 mmDevice height 80 mm 80 mm 80 mmDevice width 17.5 mm (1MU) 17.5 mm (1MU) 17.5 mm (1MU)Mounting quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protection, built-in IP40 IP40 IP40Upper and lower terminals lift terminals lift terminals lift terminalsTerminal capacity 1-10 mm2 1-10 mm2 1-10 mm2

Terminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Resistance to climatic conditions acc. to IEC/EN 60068 acc. to IEC/EN 60068 acc. to IEC/EN 60068

Connection diagramZ-T/ Z-S../ Z-S/W. Z-S/2W.

Dimensions (mm)Z-T/ Z-S/.WZ-S../

1.14Controlling & Switching

Switch Z-SW.; Signal Lamps Z-.EL, Z-.DL., Z-BEL; Pushbutton Z-PU.

14 EATON CORPORATION xxxxx+xxxx-xxxxEN

Switch Z-SW, Z-SWL

Rated voltage LED Function TypeDesignation

Article No. Units perpackage

SG59911 – 1NO Z-SW/S 276300 2 / 120– 2NO Z-SW/SS 276301 2 / 120– 1NO+1NC Z-SW/SO 276302 2 / 120– 1CO Z-SW/W 276303 2 / 12024 V AC/DC 2NO Z-SWL24/SS 276304 2 / 12024 V AC/DC 1NO+1NC Z-SWL24/SO 276305 2 / 120230 V AC/DC 1NO Z-SWL230/S 292300 2 / 120230 V AC/DC 2NO Z-SWL230/SS 276306 2 / 120230 V AC/DC 1NO+1NC Z-SWL230/SO 276307 2 / 120

Additional LED colours, voltages and contact functions upon enquiry.

• Z-SWL: with LED• 16 A 250 VAC

Busbarwa_sg02512 1pole angulated grey 10 mm2 Z-SV-10/1P-F/13 264918 10

1pole angulated blue 10 mm2 Z-SV-10/N-F/13 264919 101pole angulated grey 16 mm2 Z-SV-16/1P-1MU/F 269523 251pole angulated blue 16 mm2 Z-SV-16/N-1MU/F 269524 25Extension terminal 25 mm2 long, straight Z-EK/25 264935 10 / 600Extension terminal 25 mm2 short, straight Z-EK/25/K 269525 10 / 600Extension terminal 25 mm2 long, crosswise Z-EK/25/QL 264937 10 / 600Extension terminal 25 mm2 short, crosswise Z-EK/25/Q 264936 10 / 600

Description TypeDesignation

Article No. Units perpackage

Z-EK/25

Rated voltage LED Colour TypeDesignation

Article No. Units perpackage

24 V AC/DC orange Z-EL/OR24 275444 2 / 12024 V AC/DC white Z-EL/WH24 107493 2 / 120230 V AC/DC red Z-EL/R230 284921 2 / 120230 V AC/DC green Z-EL/G230 284922 2 / 120230 V AC/DC orange Z-EL/OR230 275865 2 / 120230 V AC/DC blue Z-EL/BL230 103131 2 / 120230 V AC/DC white Z-EL/WH230 107494 2 / 120

Signal LampsSG59211

Z-BEL/R230

Single Lamp Z-EL

2 x 24 V AC/DC red + green Z-DLD/2/24 284926 2 / 1202 x 230 V AC/DC red + green Z-DLD/2/230 284925 2 / 1202 x 24 V AC/DC white + white Z-DLD/WH24 108897 2 / 1202 x 230 V AC/DC white + white Z-DLD/WH230 108898 2 / 120

Twin Lamp Z-DLD

24 V AC/DC red/green Z-UEL24 284924 2 / 120230 V AC/DC red/green Z-UEL230 284923 2 / 120

Universal Single Lamp - changeover function Z-UEL

2 x 24 V AC/DC red/green Z-UDL24 284928 2 / 1202 x 230 V AC/DC red/green Z-UDL230 284927 2 / 120

Universal Twin Lamp - changeover function Z-UDL

24 V AC/DC red Z-BEL/R24 284931 2 / 12024 V AC/DC green Z-BEL/G24 284932 2 / 120230 V AC/DC red Z-BEL/R230 284929 2 / 120230 V AC/DC green Z-BEL/G230 284930 2 / 120

Signal Lamp - with integrated fl ash function Z-BEL

1.15

15 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingSwitch Z-SW.; Signal Lamps Z-.EL, Z-.DL., Z-BEL; Pushbutton Z-PU.

Pushbutton Z-PU, Z-PUL

Rated voltage LED Function TypeDesignation

Article No. Units perpackage

SG59811 – 1NO Z-PU/S 276291 2 / 120– 2NO Z-PU/SS 276292 2 / 120– 1NO+1NC Z-PU/SO 276293 2 / 120– 2NC Z-PU/OO 276294 2 / 12024 V AC/DC 2NO Z-PUL24/SS 276295 2 / 12024 V AC/DC 1NO+1NC Z-PUL24/SO 276296 2 / 120230 V AC/DC 2NO Z-PUL230/SS 276297 2 / 120230 V AC/DC 1NO+1NC Z-PUL230/SO 276298 2 / 120230 V AC/DC 2NC Z-PUL230/OO 276299 2 / 120

• Z-PUL: with LED• 16 A 250 VAC

Description Pushbutton Z-T/; Control Switch Z-S../; Changeover Switch Z-S/.W

• Design according to IEC/EN 60669, VDE 0632• Low power loss• Long service life• Twin lamp with separate connections• Colour red/green, can be selected by alternative wiring• Flash option by usage of different terminals only, changeover option, no additional relay necessary (Z-BEL)• Terminals with guide for secure terminal connection • Identical terminal screws for coil and contacts

Technical DataZ-.EL, Z-.DLD, Z-BEL Z-PU, Z-PUL Z-SW, Z-SWL

ElectricalRated voltage – 250 V AC 250 V ACFrequency – 50 HZ 50 HZRated current – 16 A 16 ALED

Rated voltage 230 V AC/DC 230 V AC/DC 230 V AC/DC24 V AC/DC 24 V AC/DC 24 V AC/DC

Range of operational voltage (50 V) 110-240 V AC/DC (50 V) 110-240 V AC/DC (50 V) 110-240 V AC/DC(5 V) 12-24 V AC/DC (5 V) 12-24 V AC/DC (5 V) 12-24 V AC/DC

Luminosity 15 mcd 15 mcd 15 mcdPower loss 2 W / LED 2 W 2 W

Switching contact – 16 A / 250 V~ 16 A / 250 V~Contact function – 1S, 2S, 1NO+1NC, 2Ö 1S, 2S, 1NO+1NCFlashing frequency typ. 2 Hz (Z-BEL) – –Maximum back-up fuse, short circuit – 20 A gG 20 A gGSelf-ballasted load – 200 W cap. load 200 W cap. loadMechanicalLED-Colour red, green, red + green,

white + white,red/green, orange, blue,white

orange orange

Taster-Colour – green - NOred - NCblack - NO/NC

black

Frame size 45 mm 45 mm 45 mmDevice height 90 mm 90 mm 90 mmDevice width 17.5 mm (1MU) 17.5 mm (1MU) 17.5 mm (1MU)Mounting quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protection, built-ines Gerät IP40 IP40 IP40Upper and lower terminals lift terminals with guides for secure connectionTerminal capacity

one- or more wire 1 x (0.5 ...10) mm² 1 x (0.5 ...10) mm² 1 x (0.5 ...10) mm²fi ne wires with wire end sleeve 1 x (0.5 ...10) mm² 1 x (0.5 ...10) mm² 1 x (0.5 ...10) mm²

Terminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Resistance to climatic conditions acc. to IEC/EN 60068 acc. to IEC/EN 60068 acc. to IEC/EN 60068

1.16Controlling & Switching

Switch Z-SW.; Signal Lamps Z-.EL, Z-.DL., Z-BEL; Pushbutton Z-PU.

16 EATON CORPORATION xxxxx+xxxx-xxxxEN

Connection diagramZ-EL/OR Z-UEL (red/green) Z-UDL Z-PU Z-PUL Z-SW Z-SWL

Dimensions (mm)

Connection example for LED red/greenL(+) L(+) –> same potentialN(–) = neutral conductor

Changing of colour by connecting eitherR- or G-connector terminal.

or

red green

Connection example for BlinkfunktionL(+) L(+) –> same potentialN(–) = neutral conductor

Changing of function by connecting either X2- or X3-connector terminal.

or

red

1.17

17 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingRotary Switch Z-DS

Rotary Switch Z-DS

Function Position TypeDesignation

Article No. Units perpackage

SG85211 1pole OFF 0 - 1 Z-DSA1-01 248868 1 / 401pole CO 1 - 0 - 2 Z-DSU1-102 248869 1 / 401pole CO HA - 0 - AU Z-DSU1-H0A 248870 1 / 401pole CO TA - 0 - NA Z-DSU1-T0N 248871 1 / 402pole OFF 0 - 1 Z-DSA2-01 248872 1 / 402pole OFF 0 - 1 Z-DSA2-01-SL 248873 1 / 402pole CO 1 - 2 Z-DSU2-12 248874 1 / 402pole CO 1 - 0 - 2 Z-DSU2-102 248875 1 / 402pole CO HA - 0 - AU Z-DSU2-H0A 248876 1 / 403pole CO 1 - 0 - 2 Z-DSU3-102 248877 1 / 40Voltmeter L-N L1 - N... Z-DSV-LN 248878 1 / 40Voltmeter L-L L1 - L2... Z-DSV-LL 248879 1 / 40Voltmeter L+N L1 - N3... Z-DSV-LLLN 248880 1 / 40Ammeter 0-1-2-3 Z-DSAM-0123 129712 1 / 40

Z-DSU1-102

SG85311

Z-DSA2-01-SL

Description Rotary Switch Z-DS

• Rotary switches of series Z-DS are of a modular design:The switch proper consists of the engaging work and the switching package. The switching cams (for which it is also called cam switch) are driven by a stable, torsion-proof aluminium shaft. The switching package consists of one or several switching cells with one or two independent contacts. Connections of adjoining switch terminals (necessary in case of voltmeter changeover switch Z-DSV) are contained in the pressed switch component. Consequently, there is no obstacle when connecting the connection lines.

• Application:Suitable for virtually any application, e.g. motor switch, garage doors, fans, shutters, heating system control, lighting fi xtures, instrument switches, different control purposes, etc.

1.18

Technical DataZ-DS

Data according to IEC 60947-3, IEC 60947-5-1, VDE 0660, EN 60947-3, SEVNominal thermal current

open Ith 20 Ahermetically enclosed Ithg 20 A

Nominal operational voltage Ue 690 VRated peak withstand voltage Uimp 6 kVDisconnector conditions according toÖVE, IEC met up to 440 V

Circuit breaking capacity Iv3 x 220-440V 160 A3 x 500 V 100 A3 x 660-690V 80 A

Utilisation category AC21A, AC21BSwitching resistive loads including low overloadsNominal operational current In 20 A

Utilisation category AC23A, AC23BSwitching motors and other highly inductive loadsNominal operational current 400 V In 16 ANominal power 220-240 V 4 kW3phase 3pole 380-440 V 7.5 kW3phase 3pole 500 V 7.5 kW3phase 3pole 660-690 V 7.5 kW

Star-delta starting switchfor squirrel cage motorsNominal power3phase 3pole 220-240 V 3.7 kW3phase 3pole 380-415 V 7.5 kW

Utilisation category AC3Switching of 3phase AC motorsNominal operational current 400 V In 12 ANominal power 220-240 V 3 kW3phase 3pole 380-440 V 5.5 kW3phase 3pole 500 V 5.5 kW3phase 3pole 660-690 V 5.5 kW

Utilisation category AC15Switching of electromagnetic drives, contactors, valves, pull-type electromagnetsNominal operational current to 240 V In 6 ANominal operational current 380-440 V In 4 A2pole disconnection 500 V 5 A

Utilisation category DC21A, DC21BSwitching of resistive loads, time constant L/R 1 msNominal operational current In1pole 30 V 20 A1pole 60 V 4 A1pole 110 V 0.6 A1pole 220 V 0.3 A1pole 440 V –

Utilisation category DC3 - DC5Switching of shunt motors and series motors, time constant L/R 15 msNominal operational current In1pole 30 V 8 A1pole 60 V 1 A1pole 110 V 0.3 A

Terminal capacityone or several wires 1 - 2.5 mm2

fi ne-wire 0.75 - 2.5 mm2

fi ne wires with wire end sleeve 0.75 - 1.5 mm2

terminal screw M3.5number of conductors per terminal 2

Controlling & Switching

Rotary Switch Z-DS

18 EATON CORPORATION xxxxx+xxxx-xxxxEN

1.19Controlling & SwitchingRotary Switch Z-DS

19 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical Data (continue page)Z-DS

Switching of capacitive loadmaximum making capacity up to500 V 140 A

Degree of protection from behind IP20Short circuit protection

max. fuse gL (gG) 20 ARated short-time withstand current (1 second current) 250 AConditional rated short circuit current 10 kAr.m.s.

Short-time load capacityLoad duration (values applicable to already closed contacts only)3 s 100 A10 s 60 A30 s 35 A60 s 25 A

Rotary Switch Z-DS for Lighting SystemsZ-DS

Utilisation category AC1Rated operational current 60 °C IeAC1 20 A

Utilisation category AC5aRated operational power cos 0.5 1.1 kWRated operational power 220-240 V~ cos 0.9 0.4 ARated operational power DUO 3 kW

Utilisation category AC5bRated operational power 220-240 V~ 1.4 kW

1.20

Incandescent Lamps

Utilisation category AC5b Power Current Z-DSIncandescent Lamps AC5B W A max. number of lamps per current path at 230 V, 50 Hz

60 0.27 22100 0.45 13200 0.91 7300 1.36 4500 2.27 31000 4.5 1

Fluorescent Tubes, Mercury Arc Lamps

Utilisation category AC5a Power Current Capacitor Z-DSLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

Fluorescent tubes without compensation or with series compensation

11 0.16 - 6018 0.37 2.7 2524 0.35 2.5 2536 0.43 3.4 2058 0.67 5.3 1465 0.67 5.3 1385 0.8 - 11

Fluorescent tubes lead-lag circuit 11 0.07 - 2 x 10018 0.11 - 2 x 5024 0.14 - 2 x 4036 0.22 - 2 x 3058 0.35 - 2 x 2065 0.35 - 2 x 1585 0.47 - 2 x 10

Fluorescent tubes with parallel compensation

11 0.16 2.0 3018 0.37 2.0 2024 0.35 3.0 1536 0.43 4.5 1058 0.67 7.0 665 0.67 7.0 585 0.8 8.0 4

Fluorescent tubes with electronic ballast 18 0.09 - 4036 0.16 - 2058 0.25 - 152 x 18 0.17 - 2 x 202 x 36 0.32 - 2 x 102 x 58 0.49 - 2 x 7

Mercury arc lamps, high pressure without compensation e.g.: HQL, HPL

50 0.61 - 1680 0.8 - 12125 1.15 - 8250 2.15 - 4400 3.25 - 3700 5.4 - 11000 7.5 - 1

Mercury arc lamps, high pressure with compensation e.g.: HQL, HPL

50 0.28 7 780 0.41 8 5125 0.65 10 3250 1.22 18 2400 1.95 25 1700 3.45 45 11000 4.8 60 -

Controlling & Switching

Rotary Switch Z-DS

20 EATON CORPORATION xxxxx+xxxx-xxxxEN

1.21

21 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingRotary Switch Z-DS

Metal Halide Lamps

Power Current Capacitor Z-DSLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

Metal halide lamps without compensation e.g. HQI, HPI

35 0.53 - 2270 1 - 12150 1.8 - 6250 3 - 4400 3.5 - 31000 9.5 - 12000 16.5 - -

Metal halide lamps with compensation e.g. HQI, HPI

35 0.25 6 870 0.45 12 4150 0.75 20 2250 1.5 33 1400 2.1 35 11000 5.8 95 -2000 11.5 148 -

Transformers for low-voltage halogen lamps 20 - - 4050 - - 2075 - - 13100 - - 10150 - - 7200 - - 5300 - - 3

Sodium Vapour Lamps

Power Current Capacitor Z-DSLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

Sodium vapour lamps low-pressure without compensation

35 1.5 - 755 1.5 - 790 2.4 - 4135 3.5 - 3150 3.3 - 3180 3.3 - 3200 3.3 - 3

Sodium vapour lamps low-pressure with compensation

35 0.31 20 355 0.42 20 290 0.63 30 1135 0.94 45 1150 1 40 1180 1.16 40 1200 1.32 25 1

Sodium vapour lamps high-pressure without compensation

150 1.8 - 5250 3 - 4330 3.7 - 3400 4.7 - 21000 10.3 - 1

Sodium vapour lamps high pressure with compensation

150 0.83 20 2250 1.5 33 2330 2 40 1400 2.4 48 11000 6.3 106 -

1.22

Connection diagram

Z-DSA1-01 Z-DSA2-01 Z-DSA2-01-SL Z-DSU1-102 Z-DSU1-H0A

Z-DSU1-T0N Z-DSU2-102 Z-DSU2-H0A Z-DSU3-102 Z-DSU2-12

Z-DSV-LL Z-DSV-LLLN Z-DSV-LN Z-DSAM1-0123

Dimensions (mm)

Controlling & Switching

Rotary Switch Z-DS

22 EATON CORPORATION xxxxx+xxxx-xxxxEN

1.23

23 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & Switching

Installation Relay electronic RE

Control Voltage Function MU TypeDesignation

Article No. Units perpackage

SG83411 24-250 V AC/DC 1CO+1CO 1 RELLVA 120854 124-250 V AC/DC 1CO+1CO 1 REHLVA 120855 124-250 V AC/DC 1CO+1CO 1 REMLVA 120856 1

• Far range control voltage AC/DC• 2 relays for separate energizing with one changeover contact each relay per frame• RELLVA: 2 low-level signal relay contacts DC

REHLVA: 2 power relay contacts AC/DC REMLVA: 1 low-level signal relay contact DC

1 power relay contact AC/DC

Description Installation Relay electronic RE

The electronic relay is a universal switching device designed especially for transmitting small or low-level signals of electronic control systems. The RELLVA has been designed to switch low-level signals. The relay can be energized through analogue control signals of a roller-shutter or heating control, for example. The switching contact allows to switch a binary signal for digital inputs, for example of a programmable controller, of a control relay (e.g. EASY control relay) or of a Z-CC Communication Centre.The REHLVA in turn can switch higher loads of up to 5 A 250 V AC1. It can be energized through a binary signal of a digital output, for example. The switching contact can switch electrical consumers of up to 5 A 250 V AC1, but it can also be used for energizing contactors, for example. The REMLVA is a combination of the relays mentioned above. One relay is equipped with the switching contact for low-level signals, the other one with the switching contact for higher loads up to 5 A 250 V AC1.The multi-functional coil, which can be energized in a range from 24 V to 250 V AC and DC, covers a wide variety of applications. In addition, all types have two relays for separate energizing in one enclosure of 1 MU width.

• Electronic switching relay• Universal control voltage range from 24 to 250 V AC/DC with a minimum of power consumption• 2 relays for separate energizing in one enclosure of 1 MU width• 1 change-over contact for each relay with switch position indication by LED • No switching noise, hum-free• Railway service qualifi cation tested

Connection diagram

ExamplesRELLVA

REHLVA

Switching power supply

Consumer e.g. pump

Installation Relay electronic RE

1.24

Technical DataRELLVA, REHLVA, REMLVA

ElectricalStandard according IEC/EN 61810Number of poles 2x1EMC-Environment EN 61000-4-2, 61000-4-4, 61000-4-5, 61810-5Control circuitRated voltage Us 24-250 V AC/DCRated frequency 0-50 HzOperating range 0.90-1.1 x Us

Minimum command duration 0.1 sOperating noise nonRated peak withstand voltage Uimp 4 kV (1.2/50 μs)Duty 100%Power consumtion 0.1 VA / 24 V; 1 VA / 250 VLoad Circuit Main ContactsChange over contacts 2 (to be energized separately)Rated operational voltage Ue / Rated operational current Ie

RELLVA 30 V DC / 2 A, 220 V DC / 0,3 AREHLVA 250 V AC / 5 A cos = 1, 30 V DC / 5 A, 300 V DC / 0.25 AREMLVA Switching contact 11/12/14 30 V DC / 2 A, 220 V DC / 0.3 AREMLVA Switching contact 21/22/24 250 V AC / 5 A cos = 1, 30 V DC / 5 A, 300 V DC / 0.25 A

Minimum operational voltage Umin / Minimum operational current Imin

RELLVA 10 mV / 10 μA DCREHLVA 100 mV / 10 mA AC/DCREMLVA Switching contact 11/12/14 10 mV / 10 μA DCREMLVA Switching contact 21/22/24 100 mV / 10 mA AC/DC

Rated insulation voltage Ui 500 V DCDielectric strength between open contacts

RELLVA 1.5 kVr.m.s.

REHLVA 1 kVr.m.s.

REMLVA Switching contact 11/12/14 1 kVr.m.s.

REMLVA Switching contact 21/22/24 1.5 kVr.m.s.

Dielectric strength between contacts and coil 2 kVr.m.s.

MechanicalFrame size 45 mmDevice height 90 mmDevice width 17.8 mm (1 MU)Mounting quick fastening on DIN rail IEC/EN 60715Degree of protection (built-in) IP40Mounting position as requiredShock resistance max. 750 m/s2

Terminal capacityfl exible 1x 2.5 mm2

rigid 1x 4 mm2, 2x 1.5 mm2

Temperature range -25 to +60 °C

Dimensions (mm)

45

31,7

46

70

17,8

1TE

90

Controlling & Switching

Installation Relay electronic RE

24 EATON CORPORATION xxxxx+xxxx-xxxxEN

1.25

25 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Relays Z-R.

Z-R30/16-10

Installation Relays Type Z-R

Control Voltage Function TypeDesignation

Article No. Units perpackage

sg01418_r

• with manual operation and LED• 16 A 240 V AC AC1

230-240 V, 50/60 Hz 1NO Z-R230/16-10 ICS-R16A230B100 2 / 120230-240 V, 50/60 Hz 2NO Z-R230/16-20 ICS-R16A230B200 2 / 120230-240 V, 50/60 Hz 1NC Z-R230/16-01 ICS-R16A230B010 2 / 120230-240 V, 50/60 Hz 1NO + 1NC Z-R230/16-11 ICS-R16A230B110 2 / 12024 V, 50/60 Hz 1NO Z-R24/16-10 ICS-R16A024B100 2 / 12024 V, 50/60 Hz 2NO Z-R24/16-20 ICS-R16A024B200 2 / 12024 V, 50/60 Hz 1NC Z-R24/16-01 ICS-R16A024B010 2 / 12024 V, 50/60 Hz 1NO + 1NC Z-R24/16-11 ICS-R16A024B110 2 / 12024 V DC 1NO Z-R23/16-10 ICS-R16D024B100 2 / 12024 V DC 2NO Z-R23/16-20 ICS-R16D024B200 2 / 12024 V DC 1NC Z-R23/16-01 ICS-R16D024B010 2 / 12024 V DC 1NO + 1NC Z-R23/16-11 ICS-R16D024B110 2 / 120

Accessories Spacer 0.5MU Z-DST 248949 10

Description TypeDesignation

Article No. Units perpackage

1.26Controlling & Switching

26 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Relays Z-R.

Description Installation Relays Z-R

Installation relays Z-R are suitable for switching 1-phase consumers up to 16 A. These devices for universal use in building installations and systems permit implementation of the following applications and control functions:• Switching lighting systems and electrical heating systems• Switching ventilation and air conditioning systems, fans• Switching heat pumps• Switching electrically controlled roller doors/gates, and blinds • Switching incandescent lamps and gas discharge lampsThe installation relays of series Z-R meet the requirements of standards EN/IEC 60947.

EN/IEC 60947 deals with „Electromagnetic contactors in electrical system manufacturing“.

Security:• Manual operation for testing purposes • All terminals - coil and contacts - equipped with guide for secure terminal connection. Misplacement of wires impossible.• Main contacts can be connected to standard pin busbar• Made of hardly fl ammable materials and plastics free from chlorine and halogens• Finger and hand touch safe according to VBG4

Advantages:• Low power loss• No humming• Optical operating status display by means of LED• Low switching noise• Easy to connect thanks to large terminals supplied open• Simple snap-on fastening on 35 mm DIN rail• High degree of fl exibility thanks to a variety of contact confi gurations• Easy access for coil feed connection

Connection diagrams1MU1 NO 2 NO 1 NO / 1 NC 1 NC

Versionwith manualoperation and LED

Dimensions (mm)

Permitted installation positionsmax 30°

Packing densitySpacers recommended! (Z-DST)

1.27

27 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Relays Z-R.

Technical DataZ-R

ElectricalStandard according IEC/EN 60947-4-1Rated voltage 1p: 240 V ACRated operational current AC1 Ie 16 ARated operational power Pe 3.8 kWNumber of poles 1, 2Main contacts

NO/NC 1/2Control circuitRated control feed voltage Us

AC 24, 230, 240 VDC 24 V

Minimum operational voltage Umin

230, 240 V AC 184 V AC24 V AC 19.2 V AC24 V DC 16.8 V DC

Rated frequency 50/60 HzOperating range 0.85-1.1 x Us

Maximum power of coils retaining24, 230, 240 V AC 0.75 W per pole24 V DC 0.4 W per pole

Minimum command duration > 50 msOperating noise no hummingRated peak withstand voltage (1.2/50 μs) Uimp 2.5 kVDuty 100%Load CircuitRated operational voltage Ue 240 VRated frequency 50/60 HzRated insulation voltage Ui 240 VRated peak withstand voltage (1.2/50 μs) Uimp 2.5 kVConventional thermal current Ith 16 ARated operational current Ie 16 ARated constant current Iu 16 ARated current DC Ie

24 V 16 A48 V 1.2 A120 V 0.22 A250 V 0.1 A

Conditional rated short circuit current Iq 1 kA (with 16 A gL/gG)Duration of bouncing < 10 ms (typ. < 5 ms)Max. peak inrush current 42 AMechanicalFrame size 45 mmDevice height 90 mmDevice width 17.5 mm (1MU)Mounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP20Degree of protection, built-in behind panel IP40Mounting position works in any position, however not hangingUpper and lower terminals lift terminals (captive)

M4 (combination head), captive screwTerminal capacity

Contact and coil 1 x (0.5...10) mm2 one- or more wire1 x (0.5...6) mm2 fi ne wires with wire end sleeve

Temperature range -5 to +40 °CTotal contact gap 0.6 mmContact material does not contain cadmiumEndurance

electrical components I = 16 A AC: > 700.000 switching operationsmechanical components > 1.000.000 switching operations

1.28Controlling & Switching

28 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Relays Z-R.

Utilisation categories Z-R

AC-1 *)Rated operational voltage Ue 240 V ACRated operational current Ie 16 A ACRated operational power AC-1 3072 W (cos = 0.8)

AC-3 Rated operational voltage Ue 240 V ACRated operational current Ie 3 A ACRated operational power AC-3 324 W (cos = 0.45)

AC-5a Rated operational voltage Ue 240 V ACRated operational current Ie 5 A ACRated operational power AC-5a 540 W (cos = 0.45)

AC-5b Rated operational voltage Ue 240 V ACRated operational current Ie 3 A ACRated operational power AC-5b 720 W

AC-7a (according toEN 61095) Rated operational voltage Ue 240 V ACRated operational current Ie 10 A ACRated operational power AC-7a 1920 W (cos = 0.8)Make-/break-current AC-7a Ic 24 A AC

Max. number of lampsPower Current Capacitor Z-R

Lamp Types W A μF max. number of lamps per current path at 230 V, 50 HzIncandescent Lamps 60 0.27 - 11Low-voltage halogen lamps (12 or 24 V) with transformer / electronic transformer

20 0.09 - 1850 0.22 - 775 0.33 - 4100 0.43 - 3150 0.65 - 2200 0.87 - 1300 1.3 - 1

Fluorescent tubes without compensation or with series compensation

11 0.16 0.4 2018 0.37 0.9 924 0.35 0.8 936 0.43 1.1 858 0.67 1.8 565 0.67 1.8 485 0.8 1.8 3

Fluorescent tubes lead-lag circuit 11 0.07 - 2 x 2318 0.11 - 2 x 1524 0.14 - 2 x 1136 0.22 - 2 x 758 0.35 - 2 x 465 0.35 - 2 x 485 0.47 - 2 x 3

Fluorescent tubes with parallel compensa-tion

11 0.16 1.0 1118 0.37 1.3 824 0.35 1.3 836 0.43 1.3 858 0.67 2.3 465 0.67 2.3 485 0.8 2.7 4

Fluorescent tubes with electronic ballast 18 0.09 - 1036 0.16 - 558 0.25 - 42 x 18 0.17 - 52 x 36 0.32 - 22 x 58 0.49 - 2

1.29

29 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Relays Z-R.

LED Lamps

Type of lamps Z-RLED Lamps.Pay attention on the inrush current of the ballast and cos of the lamp

max. permissible inrush current of installation relay [A]

42 A

Max. Inrush current installation relay [A]= max. number of lamps per pole (InLED Ith)Inrush current lamp [A]

1.30Controlling & Switching

30 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Relays Z-TN

Z-TN230/SO

Installation Relays Type Z-TN

Control Voltage Function MU TypeDesignation

Article No. Units perpackage

SG59711 230 V, 50 Hz 2NO 1 Z-TN230/SS 265574 2 / 120230 V, 50 Hz 3NO 2 Z-TN230/3S 265576 1 / 60230 V, 50 Hz 4NO 2 Z-TN230/4S 265579 1 / 60230 V, 50 Hz 1NO+1NC 1 Z-TN230/1S1O 267975 2 / 120230 V, 50 Hz 2NO+2NC 2 Z-TN230/2S2O 103168 1 / 6024 V, 50 Hz 2NO 1 Z-TN24/SS 267976 2 / 12024 V, 50 Hz 3NO 2 Z-TN24/3S 267977 1 / 6024 V, 50 Hz 4NO 2 Z-TN24/4S 267978 1 / 6024 V, 50 Hz 1NO+1NC 1 Z-TN24/1S1O 267979 2 / 120

• with manual pre-selection of functions - permanently ON / AUTOM / OFF• 20 A 250 V AC

Z-TN230/3S

SG60111

Accessories Spacer 0.5MU Z-DST 248949 10

Description TypeDesignation

Article No. Units perpackage

1.31

31 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Relays Z-TN

Description Installation Relays Z-TN

Installation relays Z-TN are suitable for switching 1-phase or 3-phases consumers up to 20 A. These devices for universal use in building installations and systems permit imple-mentation of the following applications and control functions: • Switching lighting systems and electrical heating systems• Switching ventilation and air conditioning systems, fans• Switching heat pumps• Switching electrically controlled roller doors/gates, and blinds • Switching incandescent lamps and gas discharge lampsThe installation relays of series Z-TN meet the requirements of standards EN/IEC 60947 and EN/IEC 1095.

EN/IEC 1095 deals with „Electromechanical contactors for household and similar purposes.“ Compliance with this standard means meeting very high demands in terms of safety for humans and property.

EN/IEC 60947 deals with „Electromagnetic contactors in electrical system manufacturing“.

Security:• Manual operation • All terminals - coil and contacts - equipped with guide for secure terminal connection. Misplacement of wires impossible.• Main contacts can be connected to standard pin busbar• Made of hardly fl ammable materials and plastics free from chlorine and halogens• Finger and hand touch safe according to VBG4

Advantages:• Low switching noise• Easy to connect thanks to large terminals supplied open• Simple snap-on fastening on 35 mm DIN rail• High degree of fl exibility thanks to a variety of contact confi gurations• Easy access for coil feed connection• Version with mechanical pre-selection of functions ON/AUTO/OFF

ON/permanently ON: Contact permanently ON until a control pulse is switched on and OFF again. Then, the relay reverts to the AUT position.AUT/AUTOMATIC: Standard relay function by control voltage at the coil.OFF/permanently OFF: Contacts permanently OFF, independently of the control voltage at the coil.

• Only in AC

Connection diagrams1MU 2MU“SS” “SO” “2S2O”2 NO 1 NO / 1 NC 2 NO / 2 NC

2MU

Versionswith mech.pre-selection

“3S” “4S”3 NO 4 NO

Dimensions (mm)1MU 2MU

Permitted installation positionsmax 30°

Packing densitySpacers recommended! (Z-DST)

1.32Controlling & Switching

32 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Relays Z-TN

Technical DataZ-TN

ElectricalStandard according IEC/EN 60947Rated voltage 250 V, 240/415 V ACRated current 250 V AC 20 ARated current AC1 Ie 20 A Rated operational power Pe 4.6 kW 415 VNumber of poles 1 to 4Main contacts

NO/NC 1/2 (1MU), 3/4 (2MU)EMC-Environment BControl circuitRated control feed voltage Us

AC 8, 12, 24, 48, 110, 230, 240 VDC 8, 12, 24, 110 V

Rated frequency 50 HzOperating range 0.85-1.1 x Us

Maximum power of coilspick-up 10-13 VA, 6-8 Wretaining 3.4-4.0 VA, 2.0-2.4 W

Minimum command duration > 50 msOperating noise low noiseRated peak withstand voltage (1.2/50 μs) Uimp 2 kVDuty 100%Load CircuitRated operational voltage Ue

1p, 2p 250 VAC3p, 4p 240/415 VAC

Minimum operational voltage Umin 24 V AC/DC (Us 8-110 V)Rated insulation voltage Ui 500 VRated peak withstand voltage (1.2/50 μs) Uimp 4 kVConventional thermal current Ith 20 A ACRated operational current Ie 20 A ACRated constant current Iu 20 A ACRated current DC Ie

24 V 16 A48 V 12.5 A230 V 1 A

Conditional rated short circuit current Iq 10 kA (with 20 A gL/gG)Duration of bouncing < 10 ms (typ. < 5 ms)MechanicalFrame size 45 mmDevice height 90 mmDevice width 17.5 mm (1MU)Mounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP20Mounting position works in any position, however not hangingUpper and lower terminals lift terminals (captive)Terminal capacity

Contact and coil 0.5 - 10 mm2 one- or more wire0.5 - 6 mm2 fi ne wires with wire end sleeve

Temperature range -20 to +45 °CTotal contact gap > 5 mm / independent contactsContact material does not contain cadmiumEndurance

electrical components 40x103 switching operationsmechanical components 1x106 switching operations

1.33

33 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Relays Z-TN

Utilisation categories 1MU, 2MU (except 3 NO, 4 NO) Z-TN

AC-1 *)Rated operational voltage Ue 250 V ACRated operational current Ie 20 A ACRated operational power AC-1 4000 W (cos = 0.8), 5000 VA

AC-3 Rated operational voltage Ue 250 V ACRated operational current Ie 8 A ACRated operational power AC-3 4000 W (cos = 0.45), 2000 VA

AC-5a Rated operational voltage Ue 250 V ACRated operational current Ie 10 A ACRated operational power AC-5a 1125 W (cos = 0.45), 2500 VA

AC-5b Rated operational voltage Ue 230 V ACRated operational current Ie 8.8 A ACRated operational power AC-5b 2024 W

AC-7a (according toEN 61095) Rated operational voltage Ue 250 V ACRated operational current Ie 20 A ACRated operational power AC-7a 4000 W (cos = 0.8), 5000 VA

Utilisation categories 2MU (3 NO, 4 NO)

AC-1 *)Rated operational voltage Ue 240/415 V ACRated operational current Ie 20 A ACRated operational power AC-1 4000 W (cos = 0.8), 5000 VA

AC-3 Rated operational voltage Ue 240/415 V ACRated operational current Ie 8 A ACRated operational power AC-3 900 W (cos = 0.45), 2000 VA

AC-5a Rated operational voltage Ue 240/415 V ACRated operational current Ie 10 A ACRated operational power AC-5a 1125 W (cos = 0.45), 2500 VA

AC-5b Rated operational voltage Ue 230/400 V ACRated operational current Ie 8.8 A ACRated operational power AC-5b 2024 W

AC-7a (according toEN 61095) Rated operational voltage Ue 240/415 V ACRated operational current Ie 20 A ACRated operational power AC-7a 4000 W (cos = 0.8), 5000 VA

AC-7b (according toEN 61095) Rated operational voltage Ue 240/415 V ACRated operational current Ie 10 A ACRated operational power AC-7b 1125 W (cos = 0.8), 2500 VA

*) suitable for insulation, tested on AC-1

1.34Controlling & Switching

34 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Relays Z-TN

Max. number of lampsPower Current Capacitor Z-TN

Lamp Types W A μF max. number of lamps per current path at 230 V, 50 HzIncandescent Lamps 60 0.27 - 33Low-voltage halogen lamps (12 or 24 V) with transformer / electronic transformer

20 0.09 - 5550 0.22 - 2275 0.33 - 14100 0.43 - 11150 0.65 - 7200 0.87 - 5300 1.3 - 3

Fluorescent tubes without compensation or with series compensation

11 0.16 1.3 6218 0.37 2.7 2724 0.35 2.5 2736 0.43 3.4 2458 0.67 5.3 1565 0.67 5.3 1485 0.8 5.3 12

Fluorescent tubes lead-lag circuit 11 0.07 - 2 x 7118 0.11 - 2 x 4524 0.14 - 2 x 3536 0.22 - 2 x 2258 0.35 - 2 x 1465 0.35 - 2 x 1485 0.47 - 2 x 10

Fluorescent tubes with parallel compensa-tion

11 0.16 3.0 3418 0.37 4.0 2624 0.35 4.0 2636 0.43 4.0 2658 0.67 7.0 1465 0.67 7.0 1485 0.8 8.0 13

Fluorescent tubes with electronic ballast 18 0.09 - 3236 0.16 - 1658 0.25 - 122 x 18 0.17 - 162 x 36 0.32 - 82 x 58 0.49 - 6

1.35

35 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors CR

Installation Contactors, 20A

Uc Rating Function TypeDesignation

Article No. Units perpackage

sg05617_r 24 V AC/DC 20 A 1NO + 1NC CR2011024 135171 124 V AC/DC 20 A 2NO CR2020024 135177 124 V AC/DC 20 A 2NC CR2002024 176469 112 V AC/DC 20 A 1NO + 1NC CR2011012 193906 112 V AC/DC 20 A 2NO CR2020012 135175 112 V AC/DC 20 A 2NC CR2002012 193907 18 V AC/DC 20 A 1NO + 1NC CR2011008 193909 18 V AC/DC 20 A 2NO CR2020008 193908 1

Accessories Spacer 0.5MU Z-DST 248949 10

Description TypeDesignation

Article No. Units perpackage

1.36Controlling & Switching

36 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Contactors CR

Description Installation Contactors CR

Contactors are frequently applied for switching of lamp loads, fans or pumps in both utility as well as industrial areas. All contactors with AC/DC coils ensure silent operation which is further enhanced by a low power consumption. Optimal contacts and low heat dissipation guarantee a long lifetime of the contactor.

Technical characteristics:• Designed according to IEC 60947-4-1 and IEC 61095 standards• Suitable for applications in general control, heating & lighting applications• Available in 20 A rating with 2-pole contacts• Coil voltages: 8 V AC/DC, 12 V AC/DC, 24 V AC/DC• DIN modular profi le• Spacers available to extend lifetime (it is recommended to use 1 spacer between every 2 contactors installed)

Advantages:• Low inrush power for all AC/DC types• Availability of combined AC/DC type contactors ensure silent operation• Contactors of AC/DC coil type are operable on both AC and DC voltage• All combined AC/DC type versions are equipped with surge protection on the operating coil• Equipped with contact indication• Optimal quality of contacts and low heat dissipation ensure a long life time

Connection diagrams2NO 1NO + 1NC 2NC

Dimensions (mm)CR

Permitted installation positions Packing densitySpacers recommended! (Z-DST)

1.37

37 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors CR

Technical DataCR

GeneralStandards IEC 60947-4-1, IEC 61095Nominal operating voltage Ue 230 VMechanical endurance 3,000,000 switching cyclesProtection class (according to DIN 40 050, IEC 529) IP20Permissible ambient temperature -5 °C up to 55 °CStorage temperature -30 °C up to +80 °CContact ratingRated insulation voltage Ui 230 VFrequency 50 - 60 HzRated impulse withstand voltage Uimp 4 kVRated thermal current Ith 20 AAC1 / AC7a Rated operational current Ie 20 AAC1 / AC7a Operational power rating at Ue = 230 VAC Pmax 4 kWAC3 / AC7b Operational power rating at Ue = 230 VAC Pmax NO: 1.3 kW; NC: 0.75 kWDC1 (L/R 1 ms) Rated thermal current

1-pole:at Ue = 24 V DC 20 Aat Ue = 110 V DC 6 Aat Ue = 220 V DC 0,6 A2-poles in series:at Ue = 24 V DC 20 Aat Ue = 110 V DC 10 Aat Ue = 220 V DC 6 A

Electrical enduranceAC1 / AC7a Application 200,000 maximum operating cyclesAC3 / AC7b Application 300,000 maximum operating cyclesAC-1/AC-3/AC-5b/AC-6b/AC-15 600 maximum operating cycles per hourPower dissipation per contact at In 1.7 WOperating coilCoil inrush power (for all voltage ratings) 2.5 WCoil consumption (for all voltage ratings) 2.5 WClosing delay 15 – 45 msOpening delay 20 − 50 msRange of control voltage Uc 85 up to 110%Kind of voltage AC / DCFrequency (AC) 50/60 HzDimensionsWidth 17.5 mmHeight 85 mmDepth 65 mmTerminals for mainTerminal capacity - fi ne stranded wire 1 to 6 mm2

Terminal capacity - solid wire 1 to 10 mm2

Terminal screw size M3,5Terminal screw head type (Pozidrive) PZ Size 1Maximum torque 1.2 NmTerminals for operating coilsTerminal capacity - fi ne stranded wire 1 to 2.5 mm2

Terminal capacity - solid wire 1 to 2.5 mm2

Terminal screw size M3,5Terminal screw head type (Pozidrive) PZ Size 1Maximum torque 0.6 Nm

1.38Controlling & Switching

38 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Contactors CR

Fluorescent Tubes, Mercury Arc Lamps

Installation Contactors CR

Power Current Capacitor CRLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

Incandescent lamps and halogen lamps 15 0.07 − 13025 0.11 − 8040 0.18 − 5060 0.26 − 3375 0.33 − 26100 0.44 − 20150 0.65 − 13200 0.87 − 10300 1.30 − 6500 2.17 − 31000 4.35 – 1

Energy saving lamps 3 0.03 − 505 0.04 − 457 0.055 − 408 0.065 − 359 0.075 − 3010 0.08 − 3011 0.09 − 3012 0.1 − 2514 0.11 − 2515 0.12 − 2016 0.13 − 2018 0.145 − 1820 0.16 − 1721 0.17 − 1523 0.185 − 1524 0.195 − 1530 0.16 − 15

Compact fl uorescent lamps - series correction

10 0.19 1.4 5013 0.18 1.4 5018 0.23 1.7 4026 0.33 2.5 3018 0.38 2.7 2524 0.35 2.7 2536 0.44 3.4 20

Compact fl uorescent lamps - parallel correction

5 0.18 2.2 137 0.18 2.1 149 0.17 2.0 1510 0.19 2.2 1311 0.16 1.7 1713 0.18 1.8 1618 0.23 2.3 1326 0.33 3.3 918 0.38 4.2 724 0.35 3.6 836 0.44 4.4 6

Compact fl uorescent lamps with electronic control gear (ECG)

5 0.05 − 457 0.05 − 459 0.07 − 3210 0.07 − 3211 0.07 − 3213 0.07 − 3218 0.22 − 1024 0.22 − 1026 0.22 − 1032 0.22 − 1036 0.22 − 1040 0.22 − 1042 0.22 − 1055 0.28 − 857 0.28 − 870 0.35 − 680 0.41 − 5120 0.58 − 4

1.39

39 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors CR

Power Current Capacitor CRLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

(to be continued)Compact fl uorescent lamps with electronic control gear (ECG)

2 x 9 0.11 − 2 x 162 x 10 0.11 − 2 x 162 x 11 0.11 − 2 x 162 x 13 0.11 − 2 x 162 x 18 0.30 − 2 x 52 x 24 0.31 − 2 x 52 x 26 0.31 − 2 x 52 x 32 0.31 − 2 x 52 x 36 0.31 − 2 x 52 x 40 0.40 − 2 x 42 x 42 0.40 − 2 x 42 x 55 0.55 − 2 x 32 x 57 0.55 − 2 x 3

Fluorescent lamps - uncorrected or seriescorrection

11 0.16 1.3 5518 0.37 2.7 2224 0.35 2.5 2236 0.43 3.4 1758 0.67 5.3 1465 0.67 5.3 1485 0.80 5.3 12

Fluorescent lamps - lead-lag circuit 2 x 11 0.07 − 2 x 502 x 18 0.11 − 2 x 302 x 24 0.14 − 2 x 242 x 36 0.22 − 2 x 172 x 58 0.35 − 2 x 102 x 65 0.35 − 2 x 92 x 85 0.47 − 2 x 6

Fluorescent lamps - parallel correction

11 0.16 3.5 918 0.37 4.5 724 0.35 4.5 736 0.34 4.5 758 0.67 7.0 465 0.67 7.0 485 0.80 8.0 3

Fluorescent lamps with electronic control gear (ECG)

18 0.09 − 2536 0.16 − 1558 0.25 − 142 x 18 0.17 − 2 x 122 x 36 0.32 − 2 x 72 x 58 0.49 − 2 x 7

High-pressure mercury-vapour lamps- uncorrected

50 0.61 − 1480 0.80 − 10125 1.15 − 7250 2.15 − 4400 3.25 − 2700 5.40 − 11000 7.50 − 1

High-pressure mercury-vapour lamps- parallel correction

50 0.28 7 480 0.41 8 4125 0.65 10 3250 1.22 18 1400 1.95 25 1700 3.45 45 −

Metal halide lamps - uncorrected

35 0.35 − 1870 1.00 − 10150 1.80 − 5250 3.00 − 3400 3.50 − 31000 9.50 − 12000 16.50 − −

Metal halide lamps - parallel correction

35 0.25 6 570 0.45 12 2150 0.75 20 1250 1.50 33 −

1.40Controlling & Switching

40 EATON CORPORATION xxxxx+xxxx-xxxxEN

Installation Contactors CR

Power Current Capacitor CRLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

Metal halide lamps with electronic control gear (PCI) + 50-125 x In lamp for 0.6 ms

20 0.10 − 935 0.20 − 670 0.36 − 5150 0.70 − 4

High-pressure sodium-vapour lamps - uncorrected

150 1.8 − 5250 3.0 − 3400 4.7 − 21000 10.3 − −

High-pressure sodium-vapour lamps - correction

150 0.83 20 1250 1.50 33 −

High-pressure sodium-vapour lamps with electronic control gear (PCI) + 50-125 x In lamp for 0.6 ms

20 0.10 − 935 0.20 − 670 0.36 − 5150 0.70 − 4

Low-pressure sodium-vapour lamps - uncorrected

18 0.35 − 2235 1.50 − 755 1.50 − 790 2.40 − 4135 3.50 − 3180 3.50 − 3

Low-pressure sodium-vapour lamps- parallel correction

18 0.35 5 635 0.31 20 155 0.42 20 190 0.63 26 1135 0.94 45 −

Transformers for low-voltage tungsten halogen lamps

20 − − 4050 − − 2075 − − 13100 − − 10150 − − 7200 − − 5300 − − 3

Fluorescent lamps T5 with electronic control gear (ECG)

22 0.11 FC 2240 0.21 FC 1255 0.28 FC 814 0.08 HE 3021 0.11 HE 2228 0.14 HE 1835 0.18 HE 1424 0.12 HO 2039 0.20 HO 1249 0.24 HO 1054 0.27 HO 980 0.39 HO 62 x 22 0.23 2 x FC 2 x 112 x 40 0.42 2 x FC 2 x 62 x 55 0.55 2 x FC 2 x 42 x 14 0.15 2 x HE 2 x 152 x 21 0.22 2 x HE 2 x 112 x 28 0.28 2 x HE 2 x 92 x 35 0.36 2 x HE 2 x 72 x 24 0.24 2 x HO 2 x 102 x 39 0.39 2 x HO 2 x 62 x 49 0.48 2 x HO 2 x 52 x 54 0.54 2 x HO 2 x 42 x 80 0.74 2 x HO 2 x 3

General remarks:– In case multiple contactors are installed in one panel it is required to multiply the above mentioned fi ttings by the applicable load factor according the IEC 60439-1.– It is recommended to install one spacer between each 2 contactors installed (e.g. contactor, contactor, spacer, contactor, etc.).

1.41

41 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors Z-SCH, CMUC

CMUC230/25-40

Installation Contactors CMUC

SG28812 230 V AC/DC 25 A 4NO CMUC230/25-40 137309 1 / 60230 V AC/DC 25 A 4NC CMUC230/25-04 137405 1 / 60230 V AC/DC 25 A 3NO+1NC CMUC230/25-31 137401 1 / 60230 V AC/DC 25 A 2NO+2NC CMUC230/25-22 137403 1 / 6024 V AC/DC 25 A 4NO CMUC24/25-40 137308 1 / 6024 V AC/DC 25 A 4NC CMUC24/25-04 137404 1 / 6024 V AC/DC 25 A 3NO+1NC CMUC24/25-31 137400 1 / 6024 V AC/DC 25 A 2NO+2NC CMUC24/25-22 137402 1 / 60

• Universal Control Voltage Us AC/DC

Installation Contactors Z-SCH

Us In AC1 Function TypeDesignation

Article No. Units perpackage

230 V AC 25 A 2NO Z-SCH230/1/25-20 120853 2 / 120230 V AC 25 A 1NO+1NC Z-SCH230/1/25-11 193886 2 / 120230 V AC 25 A 2NC Z-SCH230/1/25-02 193887 2 / 12024 V AC 25 A 2NO Z-SCH24/1/25-20 193885 2 / 12024 V AC 25 A 1NO+1NC Z-SCH24/1/25-11 193888 2 / 12024 V AC 25 A 2NC Z-SCH24/1/25-02 193984 2 / 120230 V AC 25 A 4NO Z-SCH230/25-40 248847 1 / 60230 V AC 25 A 4NC Z-SCH230/25-04 248848 1 / 60230 V AC 25 A 3NO+1NC Z-SCH230/25-31 248846 1 / 60230 V AC 25 A 2NO+2NC Z-SCH230/25-22 248849 1 / 6024 V AC 25 A 4NO Z-SCH24/25-40 248851 1 / 6024 V AC 25 A 2NO+2NC Z-SCH24/25-22 248850 1 / 60230 V AC 40 A 4NO Z-SCH230/40-40 248852 1 / 40230 V AC 40 A 3NO+1NC Z-SCH230/40-31 248854 1 / 40230 V AC 40 A 2NO+2NC Z-SCH230/40-22 248853 1 / 40230 V AC 40 A 2NO Z-SCH230/40-20 248855 1 / 40230 V AC 63 A 4NO Z-SCH230/63-40 248856 1 / 40230 V AC 63 A 4NC Z-SCH230/63-04 285735 1 / 40230 V AC 63 A 3NO+1NC Z-SCH230/63-31 248858 1 / 40230 V AC 63 A 2NO+2NC Z-SCH230/63-22 248857 1 / 40230 V AC 63 A 2NO Z-SCH230/63-20 248859 1 / 40

Z-SC

Accessories suitable for Z-SCH / CMUCSG84311 Sealing cover Z-SCHAK-2TE 248860 10

Sealing cover Z-SCHAK-3TE 248861 10Auxiliary Switch 1NO+1NC *) Z-SC 248862 3Spacer 0.5MU Z-DST 248949 10Suppressor RC-Combination 12-250 VAC Z-RC/230 101428 2 / 120

*) NOT suitable for Z-SCH.../1/...- and CMUC types

Description TypeDesignation

Article No. Units perpackage

Z-SCH230/25-40

SG84611

Z-SCH230/63-40

SG84711

Z-SCH230/1/25-20

SG84511

1.42Controlling & Switching

Installation Contactors Z-SCH, CMUC

42 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Installation Contactors Z-SCH, CMUC

These Installtion Contactors are design to cover all applications in residential and commercial sites as for as example:• Switching of lighting systems• Switching of electrical heating systems• Switching of ventilation systems• Switching of air conditioning systems and fans• Switching of heat pumps• Switching of roller doors/gates and blinds • etc. etc.

Advantages and Safety:• Front-side switch position indicator• Compact frame• Large terminals• Low switching noise• Z-SCH low noise• CMUC no humming• High contact force for high switching capacity• Simple snap-on fastening of 35 mm DIN rail• Finger and hand touch safe according to VGB 4• Hardly fl ammable materials and chlorine-free and halogen-free plastics are used• Z-SCH: Innovative AC magnet system• CMUC: Innovative AC/DC magnet system

These products meets the requirement of the standards IEC/EN 60947-4-1 and IEC/EN 61095

Connection diagram“13” “20” “22”1 NO / 3 NC 2 NO 2 NO / 2 NC

Z-SC1 NO / 1 NC

“31” “40” “04”3 NO / 1 NC 4 NO 4 NC

Permitted installation positions Packing Density at full contact loadZ-SCH / CMUCSpacers recommended!

Dimensions (mm)Z-SCH.../1/25 Z-SCH.../25 Z-SCH.../40, .../63Z-RC/230 CMUC.../25

Z-SC (NOT suitable for Z-SCH.../1/... and CMUC types)

1MU 2MU 3MU

Z-RC/230

1

2

3

4

1.43

43 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors Z-SCH, CMUC

Technical DataZ-SCH/25/.., CMUC.../25/ Z-SCH/40/.. Z-SCH/63/.. Z-SC

Data according to IEC 61095, EN 61095, VDE 0660, IEC 60947-4-1, EN 60947-4-1, VDEUtilisation category AC1 (e.g. heating system)

Rated operational current (= Ith) Inopen at 60 °C 25 A 40 A 63 A -Service life of switching element 0.1 S x 106 0.1 S x 106 0.1 S x 106 -Rated operational power AC1 220 - 240 V 9.5 kW 16 kW 25 kW -Rated operational power AC1 380 - 415 V 17 kW 27.5 kW 43 kW -Lowest switching power 24 V / 100 mA 24 V / 100 mA 24 V / 100 mA 17 V / 5 mA

Utilisation category AC3 (Switching of 3phase AC motors)Rated operational current In 9 A 27 A 30 A -Service life of switching element 0.15 S x 106 0.15 S x 106 0.15 S x 106 -Rated power of 3phase AC motors 50-60 Hz, 220 V 2.2 kW 7.5 kW 8 kW -Rated power of 3phase AC motors 50-60 Hz, 230-240 V 2.5 kW 8 kW 8.5 kW -Rated power of 3phase AC motors 50-60 Hz, 380-415 V 4 kW 12.5 kW 15 kW -

Utilisation category DC1 (Switching of resistive loads, L/R 15 ms), values for NO contacts1pole 24 V DC 25 A 40 A 63 A -1pole 48 V DC 22 A 25 A 26 A -1pole 60 V DC 18 A 19 A 21 A -1pole 110 V DC 5 A 7 A 8 A -1pole 220 V DC 0.5 A 0.7 A 0.7 A -2pole in series 24 V DC 25 A 40 A 63 A -2pole in series 48 V DC 25 A 40 A 44 A -2pole in series 60 V DC 25 A 33 A 36 A -2pole in series 110 V DC 16 A 17 A 18 A -2pole in series 220 V DC 4 A 5 A 6 A -3pole in series 24 V DC 25 A 40 A 63 A -3pole in series 48 V DC 25 A 40 A 63 A -3pole in series 60 V DC 25 A 40 A 61 A -3pole in series 110 V DC 25 A 31 A 34 A -3pole in series 220 V DC 10 A 15 A 16 A -4pole in series 24 V DC 25 A 40 A 63 A -4pole in series 48 V DC 25 A 40 A 63 A -4pole in series 60 V DC 25 A 40 A 63 A -4pole in series 110 V DC 25 A 40 A 63 A -4pole in series 220 V DC 15 A 20 A 21 A -

Utilisation category DC3 and DC5 (Switching of resistive loads, L/R 15 ms), values for NO contacts1pole 24 V DC 15 A 23 A 25 A -1pole 48 V DC 5 A 10 A 10 A -1pole 60 V DC 4 A 5 A 5 A -1pole 110 V DC 1 A 1.5 A 1.5 A -1pole 220 V DC 0.1 A 0.3 A 0.3 A -2pole in series 24 V DC 25 A 40 A 45 A -2pole in series 48 V DC 17 A 23 A 25 A -2pole in series 60 V DC 13 A 15 A 15 A -2pole in series 110 V DC 5 A 5 A 5 A -2pole in series 220 V DC 0.5 A 1 A 1 A -3pole in series 24 V DC 25 A 40 A 63 A -3pole in series 48 V DC 25 A 40 A 45 A -3pole in series 60 V DC 25 A 30 A 30 A -3pole in series 110 V DC 15 A 15 A 15 A -3pole in series 220 V DC 3 A 4 A 4 A -4pole in series 24 V DC 25 A 40 A 63 A -4pole in series 48 V DC 25 A 40 A 63 A -4pole in series 60 V DC 25 A 40 A 63 A -4pole in series 110 V DC 25 A 40 A 45 A -4pole in series 220 V DC 8 A 10 A 10 A -

Main switching elements (Uimp = 4 kV)Rated insulation voltage Ui 440 V AC 440 V AC 440 V AC 440 V ACRated operational voltage Ue 440 V AC 440 V AC 440 V AC 440 V ACPermissible switching frequency AC1, AC3 z 300 x/h 600 x/h 600 x/h 600 x/hEndurance mechanical components 1 x 106 1 x 106 1 x 106 1 x 106

1.44Controlling & Switching

Installation Contactors Z-SCH, CMUC

44 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical Data (continue page)Z-SCH/25/.., CMUC.../25/ Z-SCH/40/.. Z-SCH/63/.. Z-SC

Auxiliary switching elements (Uimp = 4 kV)Rated insulation voltage Ui 440 V AC 440 V AC 440 V AC 440 V ACNominal thermal current = Ith, 40°C 25 A 40 A 63 A 10 ANominal thermal current = Ith, 60°C 25 A 40 A 63 A 6 A

Utilisation category AC15 (Controlling of electromagnetic load)Rated operational current 220-240 V Ie - - - 3 ARated operational current 380-415 V Ie - - - 2 ARated operational current 440 V Ie - - - 1.6 A

Utilisation category DC13 (Controlling of electromagnetic load at DC)Rated operational current per pole 24-60 V Ie - - - 2 ARated operational current per pole 110 V Ie - - - 0.4 ARated operational current per pole 220 V Ie - - - 0.1 A

Trip Coil Power

Z-SCHSwitching on 14 - 18 VA 33 - 45 VA 33 - 45 VA -Holding 4.4 - 8.4 VA 7 VA 7 VA -

1.6 - 3.2 W 2.6 W 2.6 W -

CMUC 3 - 4 W - - -Operating range of trip coils multiple of Ue (-40 to +40°C)

Z-SCHCoil voltage 50 Hz 24, 220 - 240 V 220 - 240 V 220 - 240 V -Coil voltage 60 Hz 24, 230 - 264 V 230 - 264 V 230 - 264 V -

CMUCCoil voltage 50/60 Hz 24, 220-240 V - - -DC 24, 220 V

Power loss per current path Pv 2 W 3 W 7 W 0.5 WPower loss per device at nominal current load 1pole Pvges 5.2 W 5.6 W 5.6 W -Power loss per device at nominal current load 2pole Pvges 7.2 W 8.6 W 16.6 W -Power loss per device at nominal current load 3pole Pvges 9.2 W 11.6 W 23.6 W -Power loss per device at nominal current load 4pole Pvges 11.2 W 14.6 W 30.6 W -

Switching noise (on and off), typical mean values 80 dB 78 dB 78 dB -Terminal capacity

Main conductorone or several wires 1.5 - 10 mm2 2.5 - 25 mm2 2.5 - 25 mm2 0.5 - 2.5 mm2

fi ne-wire 1.5 - 6 mm2 2.5 - 16 mm2 2.5 - 16 mm2 0.5 - 2.5 mm2

fi ne wires with wire end sleeve 1.5 - 6 mm2 2.5 - 16 mm2 2.5 - 16 mm2 0.5 - 1.5 mm2

number of conductors per terminal 1 1 1 2Coilone or several wires 0.75 - 2.5 mm2 0.75 - 2.5 mm2 0.75 - 2.5 mm2 -fi ne-wire 0.5 - 2.5 mm2 0.5 - 2.5 mm2 0.5 - 2.5 mm2 -fi ne wires with wire end sleeve 0.5 - 1.5 mm2 0.5 - 1.5 mm2 0.5 - 1.5 mm2 -number of conductors per terminal 1 1 1 -

Weight 0.22 kg/unit 0.36 kg/unit 0.36 kg/unit 0.026 kg/unitTightening torque of terminal screws

Main contacts 0.8 - 1.4 Nm 2.5 - 3.0 Nm 2.5 - 3.0 Nm -Coil 0.6 - 1.2 Nm 0.6 - 1.2 Nm 0.6 - 1.2 Nm -

Short circuit protection (main circuit), maximum nominal current of fuseCo-ordination type (1), gL (gG) 35 A 63 A 80 A -

Short circuit protection (auxiliary circuit), maximum nominal current of fusesShort-circuit current 1 kA, without fusing of contacts, gL (gG) - - - 10 A

Switching times at control voltage Us ±10%Make delay 9 - 15 ms 11 - 15 ms 11 - 15 ms -Break delay 4 - 8 ms 6 - 13 ms 6 - 13 ms -Arc duration 10 - 15 ms 10 - 15 ms 10 - 15 ms -

Pollution degree 3 3 3 3Overvoltage category (grounded neutral system) 1 - 3 1 - 3 1 - 3 1 - 3

1.45

45 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors Z-SCH, CMUC

Installation Contactors Z-SCH, CMUC for Lighting Systems

Z-SCH/25/... CMUC.../25/ Z-SCH/40/.. Z-SCH/63/.. Z-SCUtilisation category AC1

Rated operational current Ie 25 A (60 °C) 40 A (60 °C) 63 A (60 °C) -Making capacity root mean square Ir.m.s. 200 A 360 A 480 A -Making capacity peak value Ipeak 280 A 510 A 680 A -

Utilisation category AC5aRated operational power 250 V cos = 0.45 1.3 kW 3.4 kW 5.5 kW -Rated operational power 220-240 V~ cos = 0.90 1.2 kW 3.1 kW 5.1 kW -DUO 3.7 kW 6.3 kW 10 kW -

Utilisation category AC5b

Rated operational power 240V~3 kW 5.7 kW 8 kW -

The decisive factors are the type, connection and current consumption of lamps dur-ing switch-on and in permanent operation. Only 90 % of the continuous current of switching devices should be used in view of higher current consumption as a result of increases of voltage. The maximum number of lamps per phase that can be operated

by a switching device is dependent on the nominal current and making current of lamps on the one hand, and on the continuous current and making capacity of the switching devices on the other. Thus, e.g. in lead-lag circuits, the continuous current of contactors can be used, while this is not possible in fl uorescent tubes with separate compensation.

Incandescent LampsThe incandescent lamp fi lament has a very low ohmic resistance when it is cold. Therefore, when switching on, there is a high peak current (up to 20x In). When switching off, only the nominal current is switched off.

Utilisation category AC5b Power Current Z-SCH/25/..CMUC.../25/

Z-SCH/40/.. Z-SCH/63/.. Z-SC

W A max. number of lamps per current path at 230 V, 50 HzIncandescent Lamps AC5B (with or except halogen)

60 0.27 50 92 129 -100 0.45 30 55 77 -200 0.91 15 27 38 -300 1.36 10 19 26 -500 2.27 6 11 16 -1000 4.5 3 6 8 -

Low voltage halogen lamps (12 or 24V) with transformer (with electronic transformer)

0.09 52 110 174 -0.22 24 50 80 -75 0.33 16 35 54 -100 0.43 12 27 43 -150 0.65 9 19 29 -200 0.87 6 14 23 -300 1.30 4 9 14 -

LED Lamps

Lamp Types Z-SCH/25/..CMUC.../25/

Z-SCH/40/.. Z-SCH/63/.. Z-SC

max. number of lamps per current pathLED Lamp. Pay attention on the inrush current of the ballast and cos of the lamp.

max. permissible inrush current contactor [A]

233 424 565 -

max. number of lamps per current path inrush current contactor [A]= max. number of lamps per current path (InLED Ith)inrush current lamp/ballast [A]

1.46Controlling & Switching

Installation Contactors Z-SCH, CMUC

46 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fluorescent Tubes, Mercury Arc Lamps

Utilisation category AC5a Power Current Capacitor Z-SCH/25/..CMUC.../25/

Z-SCH/40/.. Z-SCH/63/.. Z-SC

Lamp Types W A μF max. number of lamps per current path at 230 V, 50 HzFluorescent tubes without compensation or with series compensation

11 0.16 1.3 75 210 310 -18 0.37 2.7 34 90 140 -24 0.35 2.5 34 90 140 -36 0.43 3.4 30 70 140 -58 0.67 5.3 20 45 70 -65 0.67 5.3 19 40 65 -85 0.8 5.3 16 35 60 -

Fluorescent tubes lead-lag circuit 11 0.07 - 2 x 110 2 x 220 2 x 250 -18 0.11 - 2 x 55 2 x 130 2 x 200 -24 0.14 - 2 x 44 2 x 110 2 x 160 -36 0.22 - 2 x 33 2 x 70 2 x 100 -58 0.35 - 2 x 22 2 x 46 2 x 70 -65 0.35 - 2 x 16 2 x 40 2 x 60 -85 0.47 - 2 x 11 2 x 30 2 x 40 -

Fluorescent tubes with parallel compensa-tion

11 0.16 3.0 43 67 107 -18 0.37 4.0 32 50 80 -24 0.35 4.0 32 50 80 -36 0.43 4.0 32 50 80 -58 0.67 7.0 18 36 46 -65 0.67 7.0 18 36 46 -85 0.8 8.0 16 33 44 -

Fluorescent tubes with electronic ballast 18 0.09 - 40 100 150 -36 0.16 - 20 50 75 -58 0.25 - 15 30 55 -80 0.4 - 10 20 30 -2 x 18 0.17 - 20 50 60 -2 x 36 0.32 - 10 25 30 -2 x 58 0.49 - 7 15 20 -

Mercury arc lamps, high pressure without compensation e.g.: HQL, HPL

50 0.61 - 21 38 55 -80 0.8 - 16 28 40 -125 1.15 - 11 20 28 -250 2.15 - 6 11 15 -400 3.25 - 4 7 10 -700 5.4 - 2 4 6 -1000 7.5 - 1 3 4 -

Mercury arc lamps, high pressure with com-pensation e.g.: HQL, HPL

50 0.28 7 18 36 50 -80 0.41 8 16 31 44 -125 0.65 10 13 25 35 -250 1.22 18 7 14 19 -400 1.95 25 5 10 14 -700 3.45 45 3 6 8 -1000 4.8 60 2 4 6 -

High- and low pressure discharge lamps with mercury vapour, with or without fl uores-cent-coated glass body are perfectly identical in their electrical behaviour. In order to limit the operational current and pre-conduction current, and to achieve the initial peak voltage, reactance coils are used as ballast. Capacitors are used for compensation of the resulting reactive current, which are either connected in series

with the coil (lead-lag circuit) or parallel to the mains (separate compensation, very rarely used now). The high making current in case of separate compensation (max. 30 x nominal current of the capacitor) which goes down quickly is usually attenuated considerably by the feed line.

Utilisation category AC5aFluorescent lamps without comp. or with series comp. I = IeAC1 x 0.5Lead-lag circuit (2x..) I = IeAC1 x 0.35Fluorescent tubes with parallel compensation I = Ipeak / 100 (take into account compensation capacitor)

I / ILampe = number of connectable lamps per current path

Fluorescent tubes with electronic ballast I = Ipeak / 50Mercury arc lamps, HD without compensation I = IeAC1 x 0.5Mercury arc lamps, HD with compensation I = Ipeak / 100 (take into account compensation capacitor)

1.47

47 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors Z-SCH, CMUC

Metal Halide Lamps

Power Current Capacitor Z-SCH/25/..CMUC.../25/

Z-SCH/40/.. Z-SCH/63/.. Z-SC

Lamp Types W A μF max. number of lamps per current path at 230 V, 50 HzMetal halide lamps without compensation e.g. HQI, HPI

35 0.53 - 28 57 - -70 1 - 15 30 - -150 1.8 - 8 17 - -250 3 - 5 10 - -400 3.5 - 4 8 - -1000 9.5 - 1 3 - -2000 16.5 - - 2 - -

400 V per pole 2000 10.5 - - 2 - -3500 18 - - 1 - -

Metal halide lamps with electronic ballast (50-125 xIn) HQI

20 0.1 i 9 18 20 -35 0.2 i 6 11 13 -70 0.36 i 5 12 12 -150 0.7 i 4 10 10 -

Metal halide lamps with compensation, with parallel compensation e.g. HQI, HPI

35 0.25 6 21 42 58 -70 0.45 12 11 21 29 -150 0.75 20 7 13 18 -250 1.5 33 4 9 11 -400 2.1 35 4 9 10 -1000 5.8 95 1 3 4 -2000 11.5 148 - 2 2 -

400 V per pole 2000 6.6 58 - 3 4 -3500 11.6 100 - 2 3 -

Transformers for low-voltage halogen lamps 20 - - 52 110 174 -50 - - 24 50 80 -75 - - 16 35 54 -100 - - 12 27 43 -150 - - 9 19 29 -200 - - 5 14 23 -300 - - 4 9 14 -

Metal halide lamps are a version of high-pressure mercury arc lamps with higher luminous effi ciency and fi delity of colour (metalloids [halogens] added to the mercury fi ll up the Hg-spectrum with its many gaps). Ballast and ignition devices are necessary. Starting time 3 ... 5 minutes at 1.4 - 2 x I.After switching on, it is not possible to light the lamp again immediately (lamp extin-guishes after a power cut-off of only 1/2 period). Therefore, in many cases in important

facilities ionisation of part of the lamps is maintained by switching over to 415 V, 500 Hz (e.g. to an emergency power supply). In this case, the lamp lights immediately after the mains voltage is on again. Otherwise, this would take several minutes. When using suitable ignition devices, the lamps can be lit again immediately.

I / ILampe = number of connectable lamps per current path

Metal halide lamps (HQI) without compensation I = IeAC1 x 0.5Metal halide lamps (HQI) with compensation I = Ipeak / 100 (take into account compensation capacitor)Transformer for low voltage halogen lamps I = Ipeak / 50

1.48Controlling & Switching

Installation Contactors Z-SCH, CMUC

48 EATON CORPORATION xxxxx+xxxx-xxxxEN

Sodium Vapour Lamps

Power Current Capacitor Z-SCH/25/..CMUC.../25/

Z-SCH/40/.. Z-SCH/63/.. Z-SC

Lamp Types W A μF max. number of lamps per current path at 230 V, 50 HzSodium vapour lamps low-pressure without compensation

35 1.5 - 9 22 30 -55 1.5 - 9 22 30 -90 2.4 - 6 13 19 -135 3.3 - 4 10 14 -150 3.3 - 4 10 14 -180 3.3 - 4 10 14 -200 3.3 - 4 10 14 -

Sodium vapour lamps low-pressure with compensation, with parallel compensation

35 0.31 20 6 15 18 -55 0.42 20 6 15 18 -90 0.63 30 4 10 12 -135 0.94 45 3 7 8 -150 1 40 3 8 9 -180 1.16 40 3 8 9 -200 1.32 30 - 10 12 -

Sodium vapour lamps high-pressure without compensation

150 1.8 - 8 15 22 -250 3 - 5 10 13 -330 3.7 - 4 8 10 -400 4.7 - 3 6 8 -1000 10.3 - 1 3 4 -

Sodium vapour lamps high pressure with compensation, with parallel compensation

150 0.83 20 7 20 25 -250 1.5 33 4 12 15 -330 2 40 3 10 13 -400 2.4 48 2 8 12 -1000 6,3 106 1 4 6 -

Sodium vapour lamps high pressure with electronic ballast (50-125 xIn)

20 0.1 i 9 18 20 -35 0.2 i 6 11 13 -70 0.36 i 5 12 12 -150 0.7 i 4 10 10 -

For 200 W, 1200 mm high-pressure lamps and low-pressure lamps, reactance coils are used as ballast. For smaller lamps, stray fi eld transformers can be used as ballast. Take into account, the long starting period.Low pressure lamps: Without compens.: Making current 1 x XIe, cos 0.3; starting time 5 ... 10min Decisive for selection of device: 60% Constant current I = IeAC1 x 0.6 With compensation: Making current 20 x XIe, cos 0.45; starting time 5 ... 10min (at 1.6 x In), I = Ipeak/200

High pressure lamps: Without compens.: Making current 1.4 x XIe, cos 0.5; starting time 5 ... 10min Decisive for selection of device: 60% Constant current I = IeAC1 x 0.6 With compensation: Making current 20 x XIe, cos 0.95; starting time 5 ... 10min (at 1.6 x In)

1.49

49 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingInstallation Contactors Z-SCH, CMUC

Utilisation Categories of Contactors

Type of current

Utilisationcategory

Typical Applications Verifi cation of electrical ser-vice life

Verifi cation of switching capacity

l = Making current, Ic = Breaking current,Ie = Rated operational current, U = Voltage, Switching on Switching off Switching on Switching offUe = Rated operational voltage, Ie I U cos Ic Ur cos Ie I U cos Ic Ur cosUr = Recovery voltage A Ie Ue Ie Ue A Ie Ue Ie Ue

AC AC-1 Non-inductive or slightly inductive loadResistance furnaces

all values

1 1 0.95 1 1 0.95 all values

1.5 1.05 0.8 1.5 1.05 0.8

AC-2 Slip ring motors: starting, switching off all values

2.5 1 0.65 2.5 1 0.65 all values

4 1.05 0.65 4 1.05 0.8

AC-3 Squirrel cage motors: starting, switching off Ie 17 6 1 0.65 1 0.17 0.65 Ie 100 10 1.05 0.45 8 1.05 0.45(running motors4)) Ie > 17 6 1 0.35 1 0.17 0.35 Ie > 100 8 1.05 0.35 6 1.05 0.35

AC-4 Squirrel cage motors: starting, plugging Ie 17 6 1 0.65 6 1 0.65 Ie 100 12 1.05 0.45 10 1.05 0.45reversing, inching Ie > 17 6 1 0.35 6 1 0.35 Ie > 100 10 1.05 0.35 8 1.05 0.35

AC-5 Switching of electric discharge lamp controls 3.0 1.05 0.45 3.0 1.05 0.45AC-5b Switching of incandescent lamps 1.52) 1.05 2) 1.052) 1.05 2)

AC-6a3) Switching of transformersAC-6b3) Switching of capacitor banksAC-7a Slightly inductive loads in household applian-

ces and similar applicationsaccording to manufac-turer specifi cations

1.5 1.05 0.8 1.5 1.05 0.8

AC-7b Motor loads for household appliances 8,0 1.05 1) 8,0 1.05 1)

AC-8a Switching of hermetically enclosed refrigerant compressor motors with manual reset of over-load releases5)

6,0 1.05 1) 6,0 1.05 1)

AC-8b Switching of hermetically enclosed refrigerant compressor motors with automatic reset of overload releases5)

6,0 1.05 1) 6,0 1.05 1)

DC DC-1 Non-inductive or slightly inductive load, Resistance furnaces

all values

1 1 1 1 1 1 all values

1.5 1.05 1 1.5 1.05 1

DC-3 Shunt motors: starting, plugging, reversing, inching, dynamic braking

all values

2.5 1 2 2.5 1 2 all values

4 1.05 2.5 4 1.05 2.5

DC-5 Series motors: starting, plugging, reversing, inching, dynamic braking

all values

2 1 7.5 2.5 1 7.5 all values

4 1.05 2.5 4 1.05 2.5

DC-6 Switching of incandescent lamps 1.52) 1.05 2) 1.52) 1.05 2)

acc. to IEC 947-4-1, EN 60 947 VDE 0660 Part 102

1) cos = 0.45 for Ie 100 A; cos = 0.35 for Ie 100 A.2) The tests must be carried out with an incandescent lamp load connected.3) In this case, the test data must be derived from the test values for AC-3 or AC-4 according to

a special table.4) Devices for utilisation category AC-3 may be used for occasional inching or plugging during

a limited period, such as for setting up a machine. However, during this limited period of time, the number of operations must not exceed fi ve per minute or ten in a ten minute peri-od.

5) Hermetically enclosed refrigerant compressor motor means a combination of a compressor and a motor both of which are housed in the same enclosure with no external shaft or shaft seals, the motor running in the refrigerant.

1.50Controlling & Switching

Installation Contactors Z-SCH, CMUC

50 EATON CORPORATION xxxxx+xxxx-xxxxEN

Utilisation Categories of Auxiliary Switches

Type of current

Utilisationcategory

Typical Applications Normal conditions of use

Divergent conditions of use

l = Making current, Ic = Breaking current,Ie = Rated operational current, U = Voltage, Switching on Switching off Switching on Switching offUe = Rated operational voltage, I U cos Ic Ur cos I U cos Ic Ur cosUr = Recovery voltage, Ie Ue Ie Ue Ie Ue Ie Ue

t0.95 = the time in ms until 95% of the stationa-ry current has been reached,P = Ue x Ie = Rated power in Watts

AC AC-12 Control of resistive and solid state loads in optocoupler input circuits

1 1 0.9 1 1 0.9 - - - - - -

AC-13 Control of solid state loads with transforme-risolation

2 1 0.65 1 1 0.65 10 1.1 0.65 1.1 1.1 0.65

AC-14 Control of small electromagnetic loads (max. 72 VA)

6 1 0.3 1 1 0.3 6 1.1 0.7 6 1.1 0.7

AC-15 Control of electromagnetic loads (above 72 VA)

10 1 0.3 1 1 0.3 10 1.1 0.3 10 1.1 0.3

I U t0.95 Ic Ur t0.95 I U t0.95 Ic Ur t0.95

Ie Ue Ie Ue Ie Ue Ie Ue

DC DC-12 Control of resistive and solid state loads in optocoupler input circuits

1 1 1 ms 1 1 1 ms - - - - - -

DC-13 Control of electromagnets 1 1 6xP1) 1 1 6xP1) 1.1 1.1 6xP1) 1.1 1.1 6xP1)

DC-14 Control of electromagnetic loads with economy resistors in the circuit

10 1 15 ms 1 1 15 ms 10 1.1 15 ms 10 1.1 15 ms

acc. to IEC 947-4-1, EN 60 947 VDE 0660 Part 102

1) The value „6xP“ is the result of an empirical relationship which is found to represent most direct current magnetic loads up to an upper limit of P = 50W with 6 [ms]/[W] = 200 [ms]. Loads with a rated power above 50 W are composed of small loads located parallel to each other. Therefore, 300 ms is an upper limit independent of the power rating.

1.51

51 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingImpulse Relays Z-S

Z-S230/SO

Impulse Relays Z-S

Control Voltage Function MU TypeDesignation

Article No. Units perpackage

SG59611 240 V 50Hz 1NO 1 Z-S240/S 265261 2 / 120240 V 50Hz 2NO 1 Z-S240/SS 265269 2 / 120240 V 50Hz 1NO+1NC 1 Z-S240/SO 265282 2 / 120240 V 50Hz 2NO+2NC 2 Z-S240/2S2O 265304 1 / 60240 V 50Hz 1CO 1 Z-S240/W 265289 2 / 120240 V 50Hz 2CO 2 Z-S240/WW 265311 1 / 60240 V 60Hz 2NO 1 Z-S241/SS 265268 2 / 120230 V 50Hz 1NO 1 Z-S230/S 265262 2 / 120230 V 50Hz 2NO 1 Z-S230/SS 265271 2 / 120230 V 50Hz 4NO 2 Z-S230/4S 270335 1 / 60230 V 50Hz 1NO+1NC 1 Z-S230/SO 265283 2 / 120230 V 50Hz 2NO+2NC 2 Z-S230/2S2O 265305 1 / 60230 V 50Hz 1CO 1 Z-S230/W 265290 2 / 120230 V 50Hz 2CO 2 Z-S230/WW 265312 1 / 60230 V 60Hz 2NO 1 Z-S231/SS 265270 2 / 120110 V 50Hz 1NO 1 Z-S110/S 265263 2 / 120110 V 50Hz 2NO 1 Z-S110/SS 265273 2 / 120110 V 50Hz 1NO+1NC 1 Z-S110/SO 265284 2 / 120110 V 50Hz 2NO+2NC 2 Z-S110/2S2O 265306 1 / 60110 V 50Hz 1CO 1 Z-S110/W 265291 2 / 120110 V 50Hz 2CO 2 Z-S110/WW 265313 1 / 60110 V 60Hz 2NO 1 Z-S111/SS 265272 2 / 120110 V DC 2NO 1 Z-S109/SS 265274 2 / 120110 V DC 1CO 1 Z-S109/W 265292 2 / 120110 V DC 2CO 2 Z-S109/WW 265314 1 / 6048VAC/24VDC*) 1NO 1 Z-S48/S 265534 2 / 12048VAC/24VDC*) 2NO 1 Z-S48/SS 265536 2 / 12048VAC/24VDC*) 4NO 2 Z-S48/4S 100665 1 / 6048VAC/24VDC*) 1NO+1NC 1 Z-S48/SO 265538 2 / 12048VAC/24VDC*) 2NO+2NC 2 Z-S48/2S2O 265540 1 / 6048VAC/24VDC*) 1CO 1 Z-S48/W 265544 2 / 12048VAC/24VDC*) 2CO 2 Z-S48/WW 265542 1 / 6024VAC/12VDC*) 1NO 1 Z-S24/S 265535 2 / 12024VAC/12VDC*) 2NO 1 Z-S24/SS 265537 2 / 12024VAC/12VDC*) 1NO+1NC 1 Z-S24/SO 265539 2 / 12024VAC/12VDC*) 2NO+2NC 2 Z-S24/2S2O 265541 1 / 6024VAC/12VDC*) 1CO 1 Z-S24/W 265545 2 / 12024VAC/12VDC*) 2CO 2 Z-S24/WW 265543 1 / 6024 V 60Hz 2NO 1 Z-S25/SS 265276 2 / 12012 V 50Hz 1NO 1 Z-S12/S 265266 2 / 12012 V 50Hz 2NO 1 Z-S12/SS 265278 2 / 12012 V 50Hz 1NO+1NC 1 Z-S12/SO 265287 2 / 12012 V 50Hz 2NO+2NC 2 Z-S12/2S2O 265309 1 / 6012 V 50Hz 1CO 1 Z-S12/W 265296 2 / 12012 V 50Hz 2CO 2 Z-S12/WW 265317 1 / 608 V 50Hz 1NO 1 Z-S8/S 265267 2 / 1208 V 50Hz 2NO 1 Z-S8/SS 265280 2 / 1208 V 50Hz 1NO+1NC 1 Z-S8/SO 265288 2 / 1208 V 50Hz 2NO+2NC 2 Z-S8/2S2O 265310 1 / 608 V 50Hz 1CO 1 Z-S8/W 265297 2 / 1208 V 50Hz 2CO 2 Z-S8/WW 265318 1 / 608 V DC 2NO 1 Z-S7/SS 265281 2 / 1208 V DC 1CO 1 Z-S7/W 265298 2 / 1208 V DC 2CO 2 Z-S7/WW 265319 1 / 60

*) Doppelspannung AC/DC

• 16 A 250 VAC

1.52Controlling & Switching

Impulse Relays Z-S

52 EATON CORPORATION xxxxx+xxxx-xxxxEN

Z-SC230/S

Impulse Relays with central control Z-SC

Control Voltage Function MU TypeDesignation

Article No. Units perpackage

SG69011 240 V AC 50/60Hz 3NO 2 Z-SC240/3S 265320 1 / 60240 V AC 50/60Hz 1NO+1CO 2 Z-SC240/1S1W 265323 1 / 60240 V AC 50/60Hz 2NO+1NC 2 Z-SC240/2S1O 265326 1 / 60230 V AC 50/60Hz 1NO 1 Z-SC230/S 265299 2 / 120230 V AC 50/60Hz 3NO 2 Z-SC230/3S 265321 1 / 60230 V AC 50/60Hz 1NO+1CO 2 Z-SC230/1S1W 265324 1 / 60230 V AC 50/60Hz 2NO+1NC 2 Z-SC230/2S1O 265327 1 / 6024 V AC 50/60Hz 1NO 1 Z-SC24/S 265300 2 / 120

Z-SB230/SS

Impulse Relays with switchable LED Z-SBSG69111 230 V 50Hz 2NO 1 Z-SB230/SS 265301 2 / 120

24 V 50Hz 2NO 1 Z-SB24/SS 265302 2 / 12024 V DC 2NO 1 Z-SB23/SS 265303 2 / 120

Busbarwa_sg02512 1pole angulated grey 10 mm2 Z-SV-10/1P-F/13 264918 10

1pole angulated blue 10 mm2 Z-SV-10/N-F/13 264919 101pole angulated grey 16 mm2 Z-SV-16/1P-1MU/F 269523 251pole angulated blue 16 mm2 Z-SV-16/N-1MU/F 269524 25Extension terminal 25 mm2 long, straight Z-EK/25 264935 10 / 600Extension terminal 25 mm2 short, straight Z-EK/25/K 269525 10 / 600Extension terminal 25 mm2 long, crosswise Z-EK/25/QL 264937 10 / 600Extension terminal 25 mm2 short, crosswise Z-EK/25/Q 264936 10 / 600

Z-EK/25

Accessories for Z-S./.SG59011 Compensator 1 Z-S/KO 270588 2 / 120

Group block 1 Z-SC/GP 270587 2 / 120

Description MU TypeDesignation

Article No. Units perpackage

Z-S/KO

1.53

53 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingImpulse Relays Z-S (excluded Z-SC)

Description Impulse Relays Z-S

• Impulse relays according to EN/IEC 60669 for switching electrical consumers in impulse operation.• Shape and terminal compatible with the installation relay range• Manual operation for testing purposes is possible• Separately switchable LED (Z-SB../SS) for signalling purposes• Glow lamps of illuminated pushbuttons connected parallel produce reactive currents which may be compensated by a capacitor block in order to prevent excessive heating of

coils in case of high numbers of glow lamps.• Glow lamps parallel to control keys according to table• Main contacts can be connected to standard pin busbar

Security:• Optional optical operating status display by means of LED• Switching position indicated on the front side by manual operating key• All terminals - coil and contacts - equipped with guide for secure terminal connection. Misplacement of wires impossible.• Made of hardly fl ammable materials and plastics free from chlorine and halogens.• Finger and hand touch safe according to VBG4

Advantages:• Available in two versions (Z-S., Z-SB.)• Low switching noise• Easy to connect thanks to large terminals which are supplied open• Simple snap-on fastening on 35 mm DIN rail• High degree of fl exibility thanks to a variety of contact confi gurations• Easy access for coil connection

Accessories:Capacitor block Z-S/KO 270588

Connection diagram 1MU Z-S./.“S” “SS” “W” Z-SB../SS1 NO 2 NO 1 CO 2 NO

2MU Z-S./.“WW” “2S2O”2 CO 2 NO / 2 NC

Dimensions (mm)Z-S/KO

Packing densitySpacers obligatory! (Z-DST)

1.54Controlling & Switching

Impulse Relays Z-S (excluded Z-SC)

54 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical DataZ-S

ElectricalRated current (IEC/EN 60669-2-2) 250 V AC 16 ANumber of poles 1 to 4Main contacts

NO/NC 1/2 (1MU), 3/4 (2MU)CO 1 (1MU), 2 (2MU)

Control circuitRated control feed voltage Us

AC 8, 12, 24, 48, 230 VDC 8, 12, 24, 110 VAlternative control voltages, frequencies, and contact arrangements upon enquiry

Rated frequency 50 HzOperating range 0.9-1.1 x Us

Pickup power of coils 12 VA / 7 W typ.Max. number of parallel pushbutton units unlimitedMax. number of parallel illuminated pushbutton units 230 V 0.6 mA typ.

without compensation 8 units (1MU), 15 units (2MU)with compensation 1 x Z-SC/KO (Z-S/KO) 23 units (1MU), –with compensation 2 x Z-SC/KO (Z-S/KO) 46 units (1MU), 43 units (2MU)

Minimum command duration > 200 msOperating noise no hummingRated peak withstand voltage (1.2/50 μs) Uimp 2 kVDuty max. 1 h, 100% with spacerLoad CircuitRated operational voltage Ue

1p, 2p 250 VAC3p, 4p 240/415 VAC

Minimum operational voltage Umin 24 V AC/DC (Us 8-110 V)Rated insulation voltage Ui 500 VRated peak withstand voltage (1.2/50 μs) Uimp 4 kVConventional thermal current Ith 16 A ACRated operational current Ie 16 A ACRated constant current Iu 16 A ACRated current DC Ie

24 V 16 A48 V 12.5 A230 V 1 A

Conditional rated short circuit current Iq 10 kA (with 20 A gL/gG)Duration of bouncing < 10 ms (typ. < 5 ms)Endurance

electrical components 40x103 switching operationsmechanical components 1x106 switching operations

MechanicalFrame size 45 mmDevice height 90 mmDevice width 17.5 mm pro MUMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP20Mounting position as requiredUpper and lower terminals lift terminals (captive)Terminal capacity

Contact and coil 0.5 - 10 mm2 one- or more wire0.5 - 6 mm2 fi ne wires with wire end sleeve

Temperature range -20 to +45 °CTotal contact gap > 5mm / independent contactsContact material does not contain cadmiumAccessoriesCapacitor block 1.5 μF, 240 V AC

1.55

55 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingImpulse Relays Z-S (excluded Z-SC)

Impulse Relays with switchable LED

24 V AC and DC Application

Optionally 5LED FUNCTIONS

Impulse relayControlON/OFF

Consumer

Same power supply

LED on at CONSUMER ON

LED fl ashes at CONSUMER ON

LED perma-nently ON

LED fl ashes per-manently

LED fl ashes à permanently on when CONSUMER ON fl asher relay

LED controlled

LED continuously

1.56Controlling & Switching

Impulse Relays Z-SC with Central Control

56 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Impulse Relays Z-SC with Central Control

• Impulse relay according to EN/IEC 60669 for switching electrical consumers in impulse operation.• Local and central control, capable of switching 2-stage groups • Shape and terminal compatible with the installation relay range• Manual operation for testing purposes is possible• Glow lamps of illuminated pushbuttons connected parallel produce reactive currents which may be compensated by a capacitor block in order to prevent excessive heating of

coils in case of high numbers of glow lamps.• Glow lamps parallel to control keys according to table• Main contacts can be connected to standard busbar

Security:• Switching position indicated on the front side by manual operating key• All terminals - coil and contacts - equipped with guide for secure terminal connection. Misplacement of wires impossible. • Made of hardly fl ammable materials and plastics free from chlorine and halogens. • Finger and hand touch safe according to VBG4.

Advantages:• Low switching noise• Easy to connect thanks to large terminals which are supplied open• Simple snap-on fastening on 35 mm DIN rail• High degree of fl exibility thanks to a variety of contact confi gurations• Easy access for coil connection

• Permanent command, control by long pulse (1MU) and timer is possible

Connection diagram 1MU Z-SC./S 2MU Z-SC./.“S”1 NO

2MU Z-SC./.“2S1O” “3S”2 NO / 1 NC 3 NO

“1S1W”1 NO / 1 CO

Dimensions (mm)

Packing densitySpacers obligatory! (Z-DST)

1.57

57 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingImpulse Relays Z-SC with Central Control

Technical DataZ-SC

ElectricalRated current (IEC/EN 60669-2-2) 250 V AC 16 ANumber of poles 1 to 3Main contacts

NO 1 (1MU), 3 (2MU)NO/NC 2+1 (2MU)CO/NO 1 (2MU)

Control circuitRated control feed voltage Us

AC 12, 24, 230, 240 VAlternative control voltages, frequencies, and contact arrangements upon enquiry

Rated frequency 50 Hz; 50-60 Hz 240 VOperating range 0.9-1.1 x Us

Maximum power of coils, pick-upUs = 24 V 25 VA (15W)Us = 230 V 32 VA (19W)

Max. number of parallel pushbutton units unlimitedMax. number of parallel illuminated pushbutton units 230 V 0.6 mA typ.

without compensation 4 units (1MU, 2MU)with compensation 1 x Z-SC/KO (Z-S/KO) 19 units (1MU), 9 units (2MU)with compensation 2 x Z-SC/KO (Z-S/KO) 30 units (1MU), 18 units (2MU)

Minimum command duration > 200 msOperating noise no hummingRated peak withstand voltage (1.2/50 μs) Uimp 2 kVDuty 100% (1MU) see above, <100% (2MU), 1 h max. with spacerLoad CircuitRated operational voltage Ue

1p, 2p 250 VAC3p 240/415 VAC

Minimum operational voltage Umin 24 V AC/DC (Us 8-110 V)Rated insulation voltage Ui 500 VRated peak withstand voltage (1.2/50 μs) Uimp 4 kVConventional thermal current Ith 16 A ACRated operational current Ie 16 A ACRated constant current Iu 16 A ACRated current DC Ie

24 V 16 A48 V 12.5 A230 V 1 A

Conditional rated short circuit current Iq 10 kA (with 20 A gL/gG)Duration of bouncing < 10 ms (typ. < 5 ms)Endurance

electrical components 40x103 switching operationsmechanical components 1x106 switching operations

MechanicalFrame size 45 mmDevice height 90 mmDevice width 17.5 mm (1MU), 35 mm (2MU)Mounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP20Mounting position as requiredUpper and lower terminals lift terminals (captive)Terminal capacity

Contact and coil 0.5 - 10 mm2 one- or more wire0.5 - 6 mm2 fi ne wires with wire end sleeve

Temperature range -20 to +45 °CTotal contact gap > 5mm / independent contactsContact material does not contain cadmiumAccessoriesCapacitor block 1.5 μF, 240 V ACGroup block 240 V AC

1.58Controlling & Switching

Impulse Relays Z-SC with Central Control

58 EATON CORPORATION xxxxx+xxxx-xxxxEN

Block Diagram for Central, Group, and Local Control

Compensation by means of Capacitor Block

SPC-E-280orSPC-S-20/280

Group control

Loca

l con

trol

Central control

OFF ON

Group controlOFF ON

OFF ON

Loca

l con

trol

Loca

l con

trol

Loca

l con

trol

Loca

l con

trol

Loca

l con

trol

SPC-E-280orSPC-S-20/280

*) Identical phase at A1 as well as at ON and OFF

units unit

1.59

59 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingImpulse Relays Z-S, Z-SC, Z-SB

Utilisation categories (accoording to IEC/EN 60947-4-1)

Utilisation categories 1MU (1S, 2S, 1S+1O, 1W), 2MU (2S+2O, 2W, 3S+1O) Z-S, Z-ZC, Z-SB

AC-1 Rated operational voltage Ue 250 V ACRated operational current Ie 16 A ACRated operational power AC-1 3200 W (cos = 0.8), 4000 VAMake-/break-current AC-1 Ic 24 A AC

AC-3 Rated operational voltage Ue 250 V ACRated operational current Ie 8 A ACRated operational power AC-3 900 W (cos = 0.45), 2000 VAMake-/break-current AC-3 Ic 80 A AC

AC-5a Rated operational voltage Ue 250 V ACRated operational current Ie 10 A ACRated operational power AC-5a 1125 W (cos = 0.45), 2500 VAMake-/break-current AC-5a Ic 30 A AC

AC-5b Rated operational voltage Ue 230 V ACRated operational current Ie 8.8 A ACRated operational power AC-5b 2024 WMake-/break-current AC-5b Ic 13.2 A AC

AC-7a (according toEN 61095) Rated operational voltage Ue 250 V ACRated operational current Ie 16 A ACRated operational power AC-7a 3200 W (cos = 0.8), 4000 VAMake-/break-current AC-7a Ic 24 A AC

Utilisation categories 2MU (3S, 4S)

AC-1 Rated operational voltage Ue 240/415 V ACRated operational current Ie 16 A ACRated operational power AC-1 3200 W (cos = 0.8), 4000 VAMake-/break-current AC-1 Ic 24 A AC

AC-3 Rated operational voltage Ue 240/415 V ACRated operational current Ie 8 A ACRated operational power AC-3 900 W (cos = 0.45), 2000 VAMake-/break-current AC-3 Ic 80 A AC / 64 A AC

AC-5a Rated operational voltage Ue 240/415 V ACRated operational current Ie 10 A ACRated operational power AC-5a 1125 W (cos = 0.45), 2500 VAMake-/break-current AC-5a Ic 30 A AC

AC-5b Rated operational voltage Ue 230/400 V ACRated operational current Ie 8.8 A ACRated operational power AC-5b 2024 WMake-/break-current AC-5b Ic 13.2 A AC

AC-7a (according toEN 61095) Rated operational voltage Ue 240/415 V ACRated operational current Ie 16 A ACRated operational power AC-7a 3200 W (cos = 0.8), 4000 VAMake-/break-current AC-7a Ic 24 A AC

AC-7b (according toEN 61095) Rated operational voltage Ue 240/415 V ACRated operational current Ie 10 A ACRated operational power AC-7b 1125 W (cos = 0.8), 2500 VAMake-/break-current AC-7b Ic 30 A AC

1.60Controlling & Switching

Impulse Relays Z-S, Z-SC, Z-SB

60 EATON CORPORATION xxxxx+xxxx-xxxxEN

Power Current Capacitor Z-S, Z-ZC, Z-SBLamp Types W A μF max. number of lamps per current path at 230 V, 50 Hz

Incandescent Lamps 60 0.27 33Low-voltage halogen lamps (12 or 24 V) with transformer / electronic transformer

20 0.09 - 5550 0.22 - 2275 0.33 - 14100 0.43 - 11150 0.65 - 7200 0.87 - 5300 1.3 - 3

Fluorescent tubes without compensation or with series compensation

11 0.16 1.3 6218 0.37 2.7 2724 0.35 2.5 2736 0.43 3.4 2458 0.67 5.3 1565 0.67 5.3 1485 0.8 5.3 12

Fluorescent tubes lead-lag circuit 11 0.07 - 2 x 7118 0.11 - 2 x 4524 0.14 - 2 x 3536 0.22 - 2 x 2258 0.35 - 2 x 1465 0.35 - 2 x 1485 0.47 - 2 x 10

Fluorescent tubes with parallel compensa-tion

11 0.16 3.0 3418 0.37 4.0 2624 0.35 4.0 2636 0.43 4.0 2658 0.67 7.0 1465 0.67 7.0 1485 0.8 8.0 13

Fluorescent tubes with electronic ballast 18 0.09 - 3236 0.16 - 1658 0.25 - 122 x 18 0.17 - 162 x 36 0.32 - 82 x 58 0.49 - 6

1.61

61 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingStaircase Switch with switch-off warning and stop function TL

Staircase Switch with switch-off warning and stop function TLSG07312 Staircase switch with switchoff warning and stop function TLE 101064 2 / 120

Staircase switch as TLE, with additional control input for central control, zero-voltage proof

TLK 101066 2 / 120

Function TypeDesignation

Article No. Units perpackage

Description Staircase Switch with switch-off warning and stop function TL

• Automatic electronic staircase switch• Switch-off warning can be switched off (type TLK)• Subsequent switching is possible, programmable long-time function• Power saving function, low switching noise

• Automatic 3-/4 wire circuit recognition• Zero voltage safety thanks to memory function (type TLK)• Central control function (type TLK)• External voltage control input (type TLK)

Connection diagram

LN

L

B1 N

N

L

B1

18

18

e.g. 3 wire circuit TLE e.g. 4 wire circuit with attic lighting TLK

LN

C1L

C2

B1 N

N

L

B1

8-230VAC/DC

18

18

Dimensions (mm)

45

17,5

87

45

TLK

60

17,5

87

TLE

Functional Description

.5

TLE

15

TLK

Zeitautomatik mit Abschaltvorwarnung

Dauerlicht

Ausgeschaltet

Stromstoßschalter

Stromstoßschalter nullspannungssichert [min.]

t [min.]

0,53

6

915

Mode:

Zeitautomatik2000 W

1000 W

500 W

max. 100 mA

5

10

Modes

Automatic timing

Automatic timing with switch-off warning

Permanent light

Off

Impulse relay

Impulse relay, zero-voltage proof

B1

Rt

Mode

t 2t 3t

>2s <2s >2s <2s

R15s 10s 5s

Mode

R

Automatic timing :After pushing the button the output relay closes (terminals L-18) and the set time starts to run. If the button is pushed again before the time t has lapsed the time re-starts from zero (subsequent switching function in accordance with EN 60669-2-3). Repeated quick pressing of the pushbutton („pumping“) leads to the addition of 2, 3 or more time intervals up to 60 min. Pushing the button once for a long time (> 2 s) stops the running lighting period, and the relay switches off (power saving function). In the function, the device generates short pulses (fl ickering) as a switch-of warning (according to DIN 18015-2), 15 s, 10 s, and 5 s prior to switching off.

The additional control input permits activating the staircase switch e.g. from an intercom system by means of a voltage from 8 to 230 V AC/DC in the modes and . This input channel permits starting the lighting time, as well as subsequent switching. Switching off (power saving function) and programming of longer lighting periods („pumping“) is not possible via this input channel.

>2s<2s

R

C1-C2

B1

UMode

Mode

<2s >2s >2s

>2s<2s

R

C1-C2

B1

U

<2s >2s >2s

Impulse mode :In the impulse mode each push of the button makes the output relay switch over. In the function the output relay is always open after the feed voltage has been applied. In the function the relay immediately picks up when the feed voltage is applied provided that it was closed prior to the power failure.By applying a short voltage pulse (< 2 s) to the additional control input C1-C2 the relay R is switched on (central ON).A longer voltage pulse (> 2 s) causes the relay R to switch off (central OFF).

1.62Controlling & Switching

Staircase Switch with switch-off warning and stop function TL

62 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical DataTL

ElectricalFeed voltage 230 V ACRated voltage tolarance -15%, +10%Power consumption 6 VA (0.8 W)Rated frequency 48-63 HzDuty 100%Reset time 500 msAdjustment range 0.5 - 15 min.Overvoltage category III (in accordance with IEC 60664-1)Rated surge voltage 4 kVOutputSwitching contact 1 NO (Terminals L-18)Rated voltage 250 VACConstant current 16 ASwitch on peak current (20 ms) 80 ABreaking capacity AC 4000 VA / AC1, 384 W / DCMaximum current 30 A / < 3sSwitching voltage 250 V AC1 / 24 V DCMin. Breaking capacity DC 500 mWOutput indication yellow LED ( )Mechanical endurance 30 x 106 switching operationsElectrical endurance (AC1) 10 x 105 switching operations 16 A / 250 VControl input B1Connection (carrying voltage) Pushbutton T-N (3-wire circuit)

Pushbutton T-L (4-wire circuit)Glow lamps parallel to control keys max. 100 mAOverload protection electronicControl inputC1-C2 (Type TLK) 8-230 V AC/DCMechanicalFrame size 45 mmDevice height 87 mmDevice width 17.5 mm (1MU)Mounting quick fastening on DIN rail IEC/EN 60715Degree of protection / Pollution degree IP20 / 2Type of connection lift terminals according to VBG 4 (PZ1 required)Terminal capacity 1x 0.5-4 mm2, 2x 0.5-2.5 mm2

Tightening torque max. 1 NmTemperature range -25 to +55 °COperation position as required

1.63

63 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingTime-Lag Relay ZR

Time-Lag Relay ZR

Function Contactors TypeDesignation

Article No. Units perpackage

SG07412 E, R 1CO ZRER/W 110405 2 / 120E, R, Ws, Wa, Es, Wu, Bp 1CO ZRMF1/W 110406 2 / 120E, R, Ws, Wa, Es, Wu, Bp 2CO ZRMF2/WW 110408 1 / 60lp, li 1CO ZRTAK/W 110747 2 / 120

ZRMF1/W

SG07912

ZRMF2/WW

Description Time-Lag Relay ZR

Functions• ZRER/W

E ON delayR OFF delay

• ZRMF1/W, ZRMF2/WWE ON delayR OFF delayWs Single shot leading edge with control inputWa Single shot trailing edge with control inputEs ON delay with control inputWu Single shot leading edge voltage controlledBp Flasher pause fi rst

• ZRTAK/Wlp Asymmetric fl asher pause fi rstli Asymmetric fl asher pulse fi rst (with bridge A1-B1)

IndicatorsZRER/W, ZRMF1/W, ZRMF2/WW Green LED U/t ON: indication of supply voltageGreen LED U/t fl ashes: indication of time period Gelbe LED R ON/OFF: indication of output relayZRTAK/W Green LED U/t ON: indication of supply voltageGreen LED U/t slow fl ashing: indication of time period t1 Green LED U/t fast fl ashing: indication of time period t2 Gelbe LED R ON/OFF: indication of output relay

Connection diagramType ZRTAK/W Type ZRER/W, ZRMF1/W Type ZRMF2/WW

Time Ranges

Absolute time range Adjustment range1s 50ms 1s10s 500ms 10s1min 3s 1min10min 30s 10min1h 3min 1h10h 30min 10h100h 5h 100h

1.64Controlling & Switching

Time-Lag Relay ZR

64 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical DataZR

ElectricalStandard according EN 60669Basic accuracy ±1% (of scale end value)Setting accuracy <5% (of scale end value)Repeating accuracy: <0.5% or ±5msEffect of voltage –Effect of temperature 0.01% / °CInput circuitFeed voltage Terminals A1-A2 24 V to 240 V AC/DC, 24 V / -15% to 240 V / +10%Rated frequency 48 to 63 HzPower consumption

Type: .../W 4 VA (1.5 W)Type: .../WW 6 VA (2 W)

Duty 100%Reset time 100 msResidual ripple in case of DC 10%Release voltage >30% of min. feed voltageOutput circuit potential-free COBreaking capacity 2000 VA (8 A / 250 V AC)Fuse protection 8 A fastEndurance

electrical components at a resistive load of 1000 VA 2 x 105 switching operationsmechanical components 20 x 106 switching operations

Switching frequencyat a resistive load of 100 VA max. 60/minat a resistive load of 1000 VA (in accordance with IEC 60947-5-1) max. 6/min

Rated surge voltage 4 kVOvervoltage category III (in accordance with IEC 60664-1)Control contactInput carrying potential Terminals A1-B1

loadable yesMaximum line length 10 mOverload protection electronicMinimum control pulse length

DC 50 msAC 100 ms

Trigger level (sensitivity) automatic adaption to supply voltageMechanicalFrame size 45 mmDevice height 87 mmDevice width 17.5 mm (/W) and 35 mm (/WW)Degree of protection, built-in IP40Operation position as requiredUpper and lower terminals lift terminalsTerminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Terminal capacity 1 x 0.5-2.5 mm2 with/without multicore cable end

1 x 4 mm2 without multicore cable end2 x 0.5-1.5 mm2 with/without multicore cable end2 x 2.5 mm2 fl exible without multicore cable end

Tightening torque of terminal screws max. 1 NmPermitted relative air humidity in accordance with IEC 60721-3-3 class 3K3 15 to 85%Ambient temperature in accordance with IEC 60068-1 -25 to +55 °CStorage and transport temperature -25 to +70 °CPollution degree 2

when built in 3

Dimensions (mm)

1.65

65 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingTime-Lag Relay ZR

Description of Functions

• ON delay (E)When the supply voltage U is applied, the set interval t begins (green LED U/t fl ashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated) This status remains until the supply voltage is interrupted. If the supply voltage is inter-rupted be fore the expiry of the interval t, the interval already expired is erased and is restarted when the supply voltage is next applied.

• OFF delay (R)The supply voltage U must be constantly applied to the device (green LED U/t illuminated) When the control contact S is closed, the output relay R switch-es into on-position (yellow LED illuminated). If the control contact is opened, the set interval t begins (green LED fl ashes) After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated) If the control contact is closed again before the interval t has expired, the interval already expired is erased and is restarted.

• Single shot leading edge with control input (Ws)The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output relay R switches into on-position (green LED U/t illuminated) and the set interval t begins (green LED U/t fl ashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed.

• Single shot trailing edge with control input (Wa)The supply voltage U must be constantly applied to the device (green LED U/t illuminated). Closing the control contact S has no infl uence on the condi-tion of the output R. When the control contact is opened, the output relay switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t fl ashes). After the interval t has expired (green LED U/t illuminated), the output relay switches into off-position (yellow LED not illumi-nated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed.

• ON delay with control input (Es)The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the set interval t begins (green LED U/t fl ashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the control contact is opened again If the control contact is opened before the interval t has expired , the interval already expired is erased and is restarted with the next cycle.

• Single shot leading edge voltage controlled (Wu)When the supply voltage U is applied, the output relay R switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t fl ashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). This status remains until the supply voltage is interrupted. If the supply voltage is interrupted before the interval t has expired. The output relay switches into off-position The interval already is erased and is restarted when the supply voltage is next applied.

• Flasher pause fi rst (Bp)When the supply voltage U is applied, the set interval t begins (green LED U/t fl ashes). After the interval t has expired, the output relay R switches into on-position (yellow LED illuminated) and the set interval t begins again. After the interval t has expired. the output relay switches into off-position (yellow LED not illuminated). The output relay is triggered at a ratio of 1:1 until the supply voltage is interrupted.

• Asymmetric fl asher pause fi rst (lp)When the supply voltage U is applied, the set interval t1 begins (green LED U/t fl ashes slowly) After the interval t1 has expired. the output relay R switch-es into on-position (yellow LED illuminated) and the set interval t2 begins (green LED U/t fl ashes fast). After the interval t2 has expired, the output relay switches into off-position (yellow LED not illuminated). The output relay is triggered at the ratio of t1:t2 until the supply voltage is interrupted.

• Asymmetric fl asher pulse fi rst (li)When the supply voltage U is applied, the output relay R switches into on-position (yellow LED illuminated) and the set interval t1 begins (green LED U/t fl ashes slowly). After the interval t1 has expired, the output relay switches into off-position (yellow LED not illuminated) and the set interval t2 begins (green LED U/t fl ashes fast). After the interval t2 has expired, the output relay switches into on-position (yellow LED illuminated). The output relay is trig-gered at the ratio of t1:t2 until the supply voltage is interrupted.

1.66Controlling & Switching

Undervoltage Relay REUVM

66 EATON CORPORATION xxxxx+xxxx-xxxxEN

Undervoltage Relay REUVM

Switching voltage UN Contactors TypeDesignation

Article No. Units perpackage

SG83511 UN x 0.85 230/400 VAC 1CO REUVM 148598 1UN x 0.85 230/400 VAC 2CO REUVM2 167284 1

• Optical indicationRelay active … green LEDFault in phases L1, L2, L3 … red LED is fl ashingLoss of Neutral conductor N … green LED is fl ashing

• Single phase application is possible

Description Undervoltage Relay REUVM

• When the connection to the three phases and neutral conductor is made the relay is energized in case there is no fault and the green LED lights. If the monitored nominal vollta-ge UN drops under the switching voltage US, in one, two or all three phases the relay reverts to its de-energized position. The green LED disappear.

• Optical indicationRelay active … green LEDFault in phases L1, L2, L3 … red LED is fl ashingLoss of Neutral conductor N … green LED is fl ashing

• Single-phases operation: bridge L1-L2-L3

Technical DataREUVM

ElectricalRated operational voltage UN 230/400 V ACRated frequency 50-60 HzSwitching voltage US UN x 0.85 fi xPower consumption < 1 VASwitching time delay 500 msSwitching contact 1 CO, 2 CORated operational voltage / current 250 VAC / 5A cos = 1

30 VDC / 5A300 VDC / 0.25A

Min. Rated operational voltage 100 mV AC/DCMin. Rated operational current 10 mA AC/DCRated peak withstand voltage 4 kVDuty 100%Overvoltage category IIIDielectric strength

Coil – contact circuit 4 kVr.m.s.

Open circuit contact 1 kVr.m.s.

MechanicalFrame size 45 mmDevice height 90 mmDevice width 17.8 mmWeight 65 g, 73 gMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP40Upper and lower terminals lift terminalsTerminal capacity

solid 1x4 mm2, 2x1.5 mm2

fi ne-wire 1x2.5 mm2

Tightening torque of terminal screws 0.5 NmResistance to climatic conditions F / DIN 40040Temperature range -25 to +60 °CFlame class V0, glow wire 960 °CPollution degree 2Comparative tracking index CTI 600

1.67

67 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingUndervoltage Relay REUVM

REUVM REUVM2

12 14

11

L3L2L1

N

U<

L

Single-phases application

Connection diagram

Dimensions (mm)

Functional diagram

Optical indication and contact position

12 14

11

L3L2L1

N

U<

Operation

12 14

11

L3L2L1

N

U<

22 24

21Relay active

Fault

Loss of N

Example Phase L2

1.68Controlling & Switching

Voltage Indication UVA

68 EATON CORPORATION xxxxx+xxxx-xxxxEN

Voltage Indication UVA

Rated operational voltage TypeDesignation

Article No. Units perpackage

SG00112 230/400 V AC, 50/60 Hz UVA 167285 1

• Optical indicationVoltage of phases L1, L2, L3 is indicated with green LED‘s even at loss of Neutral conductor N

• Single-phases application, or even possible to use DC

Description Voltage Indication UVA

• When the connection to the three phases and neutral conductor is made, the green Power LED lights. If only two phases are connected, eg. L1 and L3, only these green LED`s lights, even at loss of Neutral conductor N.

• For use as voltage return indication in manual operated Mains-Emergency-system operation• Large operational voltage range 85-480 V AC, 85-300 V DC

Technical DataUVA

ElectricalRated operational voltage UN 230/400 V ACRated frequency 50-60 HzRated operational voltage range

L-L 85-480 V ACL-N 85-300 V AC/DC

Power consumption at 400 V AC 3x 23 mWMax. permissible back-up fuse 16A gG (gL)Duty 100%Rated peak withstand voltage 6 kVOvervoltage category IVMechanicalFrame size 45 mmDevice height 90 mmDevice width 17.8 mmWeight 42 gMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP40Upper and lower terminals lift terminalsTerminal capacity

solid 1x4 mm2, 2x1.5 mm2

fi ne-wire 1x2.5 mm2

Tightening torque of terminal screws 0.5 NmTemperature range -30 to +60°CFlame class V0, glow wire 960 °CPollution degree 2Comparative tracking index CTI 600

Connection diagram

1.69

69 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingVoltage Indication UVA

Dimensions (mm)

3N~ 3~

Application and visuale indicators

L1

N

L3

L2

L1

L3

L2

N

1~DC

–(+)+(–)L1

1.70Controlling & Switching

Load Shedding (Current) Relay Z-LAR

70 EATON CORPORATION xxxxx+xxxx-xxxxEN

Load Shedding (Current) Relay Z-LAR

Function Rated operational current range(A)

TypeDesignation

Article No. Units perpackage

SG78711 NC 3-8 Z-LAR/8-O 248256 1 / 60NC 10-16 Z-LAR/16-O 248257 1 / 60NC 15-32 Z-LAR/32-O 248258 1 / 60NO 3-8 Z-LAR/8-S 248259 1 / 60NO 10-16 Z-LAR/16-S 248260 1 / 60NO 15-32 Z-LAR/32-S 248261 1 / 60CO 3-8 Z-LAR/8-W 248262 1 / 60

Description Load Shedding (Current) Relay Z-LAR

• For simple priority connection of important consumers• For fast current increase• Expensive peak loads are avoided effi ciently (staggered heating)• Integrated auxiliary switch, 1 NC or 1 NO or 1 CO contact• NC and NO contact are potential free

Technical DataZ-LAR/8 Z-LAR/16 Z-LAR/32

ElectricalNominal thermal current Ith 8 A 16 A 32 ARated voltage U 250 V AC 250 V AC 250 V ACResponding current IAN 3 A 10 A 15 ARelease current IA 1.8 A 4.2 A 7.4 AMax. electrical switching frequency 3600/h 3600/h 3600/hRated insulation voltage Ui 440 V 440 V 440 VPower loss at Ith

Effective power 3.4 W 1.95 W 3.17 WApparent power 7.7 VA 4.66 VA 7,36 VA

Rated peak withstand voltage Uimp 4 kV 4 kV 4 kVBack-up fuse line protection max. 10 A max. 16 A max. 32 ASwitching contact

Function NC, NO, COBack-up fuse max. 1 A gL max. 1 A gL max. 1 A gLContact gap *) < 3 mm (μ) < 3 mm (μ) < 3 mm (μ)Breaking capacity 1 A / 250 V~ 1 A / 250 V~ 1 A / 250 V~Minimum switching capacity 300 mW 300 mW 300 mWMinimum operational voltage 12 V 12 V 12 V

Endurance electrical components 100,000 switching operations*) Do not use as the only means of isolating a device from the line voltageMechanicalFrame size 45 mm 45 mm 45 mmDevice height 80 mm 80 mm 80 mmDevice width 17.5 mm (1MU) 17.5 mm (1MU) 17.5 mm (1MU)Mounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP40 IP40 IP40Terminal protection fi nger and hand touch safe according to DGUV VS3, EN 50274Upper and lower terminals lift terminals lift terminals lift terminalsTerminal capacity

Main circuit 2 x 10 mm2 2 x 10 mm2 2 x 10 mm2

Auxiliary circuit 2 x 2.5 mm2 2 x 2.5 mm2 2 x 2.5 mm2

Tightening torque of terminal screwsMain circuit max. 2.4 Nm max. 2.4 Nm max. 2.4 NmAuxiliary circuit max. 1 Nm max. 1 Nm max. 1 Nm

1.71

71 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingLoad Shedding (Current) Relay Z-LAR

Connection diagramType -O Type -S Type -W

Dimensions (mm)

Connection Example - Operating Status Connection Example - Priority for Pump

Connection Example - „OR“ Circuit, Extraction System

green . . . . Motor ONred . . . . . . Motor STOP

e.g. heating system

e.g. fan

1.72Controlling & Switching

Digital Timers with a Weekly Program TSDW

72 EATON CORPORATION xxxxx+xxxx-xxxxEN

Digital Timers TSDW

Drive Program Channels TypeDesignation

Article No. Units perpackage

Digital Week 1 channel TSDW1CO 167379 1Digital Week 2 channels TSDW2CO 167380 1DCF/GPS Week 1 channel TSDW1CODG 167382 1Digital Week 1 channel TSDW1COMIN 167383 1Digital Week 1 channel TSDW1CO-1 196848 1Digital Week 2 channels TSDW2CO-1 196849 1

AccessoriesDCF antenna for timers digital TSDW1CODG TSADCF 167384 1GPS antenna with power supply for TSDW1CODG TSAGPSKIT 167385 1PC Set + memory card for SRCD1CO, TSDW1CO, TSDW2CO, TSDW1COA, TSDW1CODG

TSAMEMKIT 167386 1

Memory card TSAMEM 167387 1

Description TypeDesignation

Article No. Units perpackage

PHASE OUT

NEW

NEW

PHASE OUT

PHASE OUT

PHASE OUT

PHASE OUT

PHASE OUT

sg06219_l

sg60612

1.73

73 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingDigital Timers with a Weekly Program TSDW1CO, TSDW2CO

Connection example

Dimensions (mm)

Description Digital Timers with a Weekly Program TSDW1CO, TSDW2CO

• Spring terminals• Text-based user guidance on the display• 56 memory cells• Interface for memory card (PC programming)• 10 years power backup (lithium battery)• Zero-cross switching for a relay-saving way of switching and for high lamp loads• ON-OFF switching times• Pre-selected switching

• Permanent ON/OFF switching• Integrated counter for operating hours• Vacation program• Display background lighting (can be switched off)• PIN coding• Automatic spring forward/fall back at daylight-saving start and end dates• TSDW1CO: 1 channel• TSDW2CO: 2 channels

Technical DataTSDW1CO TSDW2CO TSDW1CO-1 TSDW2CO-1

ElectricalRated operational voltage 230–240 V AC 230–240 V AC 230 V AC 230 V ACFrequency 50–60 Hz 50–60 Hz 50 – 60 Hz 50 – 60 HzStand-by Power (typical) 0.8 W 0.8 W 0.4 W 0.4 WPower backup 10 years 10 years 10 years 10 yearsAccuracy (typical) ± 0.5 s/day (quartz) ± 0.5 s/day (quartz) ± 0.25 s/day at 25 °C (quartz) ± 0.25 s/day at 25 °C (quartz)Switching capacity

at 250 V AC, cos = 1 16 A 16 A 16A 16Aat 250 V AC, cos = 0.6 10 A 10 A 10A 10A

Incandescent/halogen lamp load 2600 W 2600 W 2600 W 2600 WEnergy saving lamps 230 V 22 x 7 W, 18 x 11 W, 16 x 15 W,

16 x 20 W, 14 x 23 W"22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W"

1100 W 1100 W

LED lamp < 2 W 50 W 50 WLED lamp > 2 W 600 W 600 WFluorescent lamp load (conventional)

not corrected 1000 VA 1000 VA 2600 VA 2600 VAseries corrected 1000 VA 1000 VA 2600 VA 2600 VAparallel corrected 730 VA, 80 μF 730 VA, 80 μF 1300 VA 130 μF 1300 VA 130 μF

Min. switching capacity ca.10 mA ca.10 mA ca.10 mA ca.10 mAShortest switching time 1 min 1 min 1 min 1 minMechanicalFrame size 45 mm 45 mm 45 mm 45 mmDevice width 36 mm 36 mm 36 mm 36 mmMounting DIN rail DIN rail DIN rail DIN railWidth 2 modules 2 modules 2 modules 2 modulesType of connection Duo fi x spring terminals Duo fi x spring terminals Duo fi x spring terminals Duo fi x spring terminalsAmbient temperature -30 to +55 °C -30 to +55 °C -30 °Cto +60 °C -30 °C to +60 °CDegree of protection IP20 IP20 IP20 IP20Protection class II according to EN 60730-1 II according to EN 60730-1 II according to EN 60730-1 II according to EN 60730-1Certifi cation mark V V V V

NEW NEWPHASE OUT PHASE OUT

TSDW1CO / TSDW1CO-1 TSDW2CO / TSDW2CO-1

1.74Controlling & Switching

Digital Timers with a Weekly Program TSDW1CODG

74 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Digital Timers with a Weekly Program TSDW1CODG

• Spring terminals• Text-based user guidance on the display• 84 memory cells• Interface for memory card (PC programming)• 10 years power backup (lithium battery)• Zero-cross switching for a relay-saving way of switching and for high lamp loads• ON-OFF switching times• Pulse program• Cyclical program• Pre-selected switching• Permanent ON/OFF switching

• Expiry timer• Integrated counter for operating hours• Vacation program• 2 random programs• Display background lighting (can be switched off)• PIN coding• Automatic spring forward/fall back at daylight-saving start and end dates• Time synchronization is possible by connecting an external aerial, e. g. a TSADCF or

TSAGPSKIT aerial set• 1 channel• External input

Technical DataTSDW1CODG

ElectricalRated operational voltage 230–240 V ACFrequency 50–60 HzPower backup 10 yearsBreaking capacity

at 250 V AC, cos = 1 16 Aat 250 V AC, cos = 0.6 10 A

Incandescent/halogen lamp load 2600 WMin. switching capacity ca.10 mAShortest switching time 1 sAccuracy ± 0.5 s/day (quartz) or DCF77/GPSStand-by Power 1.4 WMechanicalFrame size 45 mmDevice width 36 mmMounting DIN railDegree of protection IP20Protection class II according to EN 60730-1Ambient temperature -30 to +55 °CCertifi cation mark V

Connection example

Dimensions (mm)

PHASE OUT

1.75

75 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingDigital Timers with a Weekly Program TSDW1COMIN

Description Digital Timers with a Weekly Program TSDW1COMIN

• 1 channel• Screw-type terminals• Text-based operator guidance on the display• 28 memory cells• 3 years Power backup (exchangeable lithium battery)• ON-OFF switching times• Pre-selected switching• Permanent ON/OFF switching• PIN coding• Automatic spring forward/fall back at daylight-saving start and end dates

Technical DataTSDW1COMIN

ElectricalRated operational voltage 230 V ACFrequency 50–60 HzPower backup 3 yearsBreaking capacity

at 250 V AC, cos = 1 16 Aat 250 V AC, cos = 0.6 6 A

Incandescent/halogen lamp load 1000 WShortest switching time 1 minAccuracy ± 1 s/day (quartz)Stand-by Power 0.4 WMechanicalFrame size 45 mmDevice width 17.5 mmMounting DIN railDegree of protection IP20Protection class II according to EN 60730-1Ambient temperature -10 to +55 °CCertifi cation mark V

Connection example

Dimensions (mm)

1.76Controlling & Switching

Astronomical Timer with a Weekly Program

76 EATON CORPORATION xxxxx+xxxx-xxxxEN

Astronomical Timer with a Weekly Program TSDW1COA

Drive Program Channels TypeDesignation

Article No. Units perpackage

sg06119_l Quartz Week 1 channel TSDW1COA 167381 1Quartz Week 1 channel TSDW1COA-1 196850 1

Description Astronomical Timer with a Weekly Program TSDW1COA

• Astronomical switching function (automatic calculation of sunrise and sunset times for the entire year)

• Spring terminals• Text-based user guidance on the display• Interface for memory card (PC programming)• 10 years power backup (lithium battery)• Zero-cross switching for a relay-saving way of switching and for high lamp loads• Calculated astronomical switching times• Programmable ON/OFF switching times

• Pre-selected switching• Permanent ON/OFF switching• Integrated counter for operating hours• Vacation program• Display background lighting (can be switched off)• PIN coding• Automatic spring forward/fall back at daylight-saving start and end dates• 1 channel• 54 memory cells

Connection example Dimensions (mm)

PHASE OUT

NEW

Technical DataTSDW1COA TSDW1COA-1

ElectricalRated operational voltage 230–240 V AC 230 V ACFrequency 50–60 Hz 50 – 60 HzStand-by Power (typical) 0.8 W 0.4 WPower backup 10 years 10 yearsAccuracy (typical) ± 0.5 s/day (quartz) at 25 °C typical ± 0,25 s/day (quartz)Switching capacity

at 250 V AC, cos = 1 16 A 16Aat 250 V AC, cos = 0.6 10 A 10A

Incandescent/halogen lamp load 2600 W 2600 WEnergy saving lamps 230 V 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W 1100 WLED lamp < 2 W 50 WLED lamp > 2 W 600 WFluorescent lamp load (conventional)

not corrected 2300 VA 2600 VAseries corrected 2300 VA 2600 VAparallel corrected 730 VA, 80 μF 1300 VA 130 μF

Min. switching capacity ca.10 mA ca.10 mAShortest switching time 1 min 1 minMechanicalFrame size 45 mm 45 mmDevice width 36 mm 36 mmMounting DIN rail DIN railWidth 2 modules 2 modulesType of connection DuoFix spring terminals DuoFix spring terminalsAmbient temperature -30 to +55 °C -30 to +55 °CDegree of protection IP20 IP20Protection class II according to EN 60730-1 II according to EN 60730-1Certifi cation mark V V

NEWPHASE OUT

TSDW1COA / TSDW1COA-1

1.77

77 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingAnalogue Timers TS

Analogue Timers TS

Drive Program Channels TypeDesignation

Article No. Units perpackage

SG83911 Quartz Day 1 channel TSQD1NO 167388 1Synchron Day 1 channel TSSD1NO 167389 1Quartz Day 1 channel TSQD1CO 167390 1Synchron Day 1 channel TSSD1CO 167391 1Quartz Week 1 channel TSQW1CO 167392 1

1.78Controlling & Switching

Analogue Timers TSQD1NO, TSSD1NO

78 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Analogue Timers TSQD1NO, TSSD1NO

• 1 MU• 1 channel• Screw-type terminals• Manual switch with 3 positions: Permanent ON/AUTO/Permanent OFF• Switching status indication

• TSQD1NO: with power backup (Internal rechargeable battery)- Quartz-controlled

• TSSD1NO: Daily program- Without power backup- 96 switching segments- Mains-synchronized- Shortest switching time: 15 minutes

Technical DataTSQD1NO TSSD1NO

ElectricalRated operational voltage 230–240 V AC 230 V ACFrequency 50–60 Hz 50 HzProgram Daily program Daily programPower backup 3 days –Breaking capacity

at 250 V AC, cos = 1 16 A 16 Aat 250 V AC, cos = 0.6 4 A 4 A

Shortest switching time 15 min 15 minProgrammable every 15 min every 15 minAccuracy ± 1 s/day (quartz) Mains-synchronizedStand-by Power 0.5 W 0.9 WMechanicalFrame size 45 mm 45 mmDevice width 17.5 mm 17.5 mmMounting DIN rail DIN railDegree of protection IP20 IP20Protection class II according to EN 60730-1 II according to EN 60730-1Ambient temperature -10 to +55 °C -25 to +55 °CCertifi cation mark V V

Connection example

Dimensions (mm)

1.79

79 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingAnalogue Timers TSQD1CO, TSSD1CO, TSQW1CO

Description Analogue Timers TSQD1CO, TSSD1CO, TSQW1CO

• 3 MU• 1 channel• Spring terminals• Pre-selected switching• Manual switch with 3 positions: Permanent ON/AUTO/Permanent OFF• Switching status indication• TSQD1CO:

- With power backup (NiMH cell)- Quartz-controlled- Clock-hands for time indication and 12h/24h recognition- Easy correction of spring forward/fall back at daylight-saving start and end

• TSQW1CO: - Weekly program- 84 switching segments- Shortest switching time: 2 hours

• TSSD1CO: - Daily program- Without power backup- 96 switching segments- Shortest switching time: 15 minutes- Clock-hands for time indication and 12h/24h recognition- Easy correction of spring forward/fall back at daylight-saving start and end

Technical DataTSQD1CO TSSD1CO TSQW1CO

ElectricalRated operational voltage 110–230 V AC 110–230 V AC 110–230 V ACFrequency 50–60 Hz 50 Hz 50–60 HzProgram Daily program Daily program Weekly programPower backup 200 hours, approx. 100 hours

at 110 V– 200 hours, approx. 100 hours

at 110 VBreaking capacity

at 250 V AC, cos = 1 16 A 16 A 16 Aat 250 V AC, cos = 0.6 4 A 4 A 4 A

Shortest switching time 15 min 15 min 2 hProgrammable every 15 min every 15 min alle 2 hAccuracy ± 1 s/day (quartz) Mains-synchronized ± 1 s/day (quartz)Stand-by Power 0.5 W 0.9 W 0.5 WMechanicalFrame size 45 mm 45 mm 45 mmDevice width 52.5+1.5 mm 52.5+1.5 mm 52.5+1.5 mmMounting DIN rail DIN rail DIN railDegree of protection IP20 IP20 IP20Protection class II according to EN 60730-1 II according to EN 60730-1 II according to EN 60730-1Ambient temperature -20 to +55 °C -20 to +55 °C -20 to +55 °CCertifi cation mark V V V

Connection example

Dimensions (mm)

1.80Controlling & Switching

Light Intensity Switch SR

80 EATON CORPORATION xxxxx+xxxx-xxxxEN

Switching contact

Brightness range Brightness adjustable

Mounting DIN rail Size

TypeDesignation

Article No. Units perpackage

Light Intensity Switch SRSD1NO 2-100 Lux Analog DIN rail 1TE SRSD1NO 167375 11CO 2-2000 Lux Analog DIN rail 2TE SRSD1COW 167378 11NO 2-2000 Lux Analog DIN rail 1TE SRSD1NOW 196845 1

PHASE OUT

NEW

PHASE OUT

sg06019_l

Light Intensity Switch SRSW1NO 2-2000 Lux Analog Wall SRSW1NO 167376 11NO 2-100 / 100-2000 Lux Analog, Digital Wall SRSW1NOW 196846 1

Light Intensity Switch with timer SRC

NEW

NEW

PHASE OUT

PHASE OUT1CO 2-2000 Lux Analog DIN rail 3TE SRCD1CO 167377 11NO 1-99000 Lux Digital DIN rail 2TE SRCD1COD 196847 1

sg05819_r

sg05919_l

1.81

81 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingLight Intensity Switch analog for DIN rail SRSD

Description Light Intensity Switch analog for DIN rail SRSD1NOW

• Analog twilight switch• External surface-mounted light sensor, cadmium sulfi de (CdS) free• Indication of the channel and switching status• Freely adjustable switching brightness

• Wide lux range: 2 - 2000 lux• Fixed on/off switching delay, preventing faulty operation caused by lightning, car headlights, etc. • Improved switching capabilities: LED 350W (>2W)• Reduced Power standby: ~0,3 W

Technical Data

Connection diagramSRSD1NO / SRSD1NOW SRSD1COW

Dimensions (mm)SRSD1NO / SRSD1NOW SRSD1COW

SRSD1NO SRSD1COW SRSD1NOWElectricalRated operational voltage 220–240 V AC 220–240 V AC 230 V AC, +10%/-15%Frequency 50–60 Hz 50 Hz 50–60 HzStand-by Power (typical) 0.8 W 1.3 W 0.3 WSetting range for brightness 2–100 lx 2-2000 lx 2-2000 lxSwitch-on delay 20 s 60 s 20 sSwitch-off delay 80 s 60 s 80 sContact type NO CO NOSwitch output Potential-free Potential-free, not suitable for SELV Potential-free Switching capacity

at 250 V AC, cos = 1 16 A 16 A 16 AFluorescent lamp 10 AX 10 AX 10 AX

Incandescent/halogen lamp load 2300 W 2300 W 2600 WEnergy saving lamps 9 x 7 W, 7 x 11 W, 7 x 15 W,

7 x 20 W, 7 x 23 W34 x 7 W, 27 x 11 W, 24 x 15 W, 22 x 23 W

LED lamp < 2 W 20 W 20 W 30 WLED lamp > 2 W 70 W 70 W 350 WFluorescent lamp load (conventional)

not corrected 2300 VA 2300 VA 2300 VAseries corrected 2300 VA 2300 VA 2300 VAparallel corrected 400 VA 42 μF 400 VA 42 μF 730 VA, 80 μF

Fluorescent lamp (electronic ballast) 300 VA 300 VA 650 VAMin. switching capacity - <10 mA <10 mAMechanicalFrame size 45 mm 45 mm 45 mmDevice width 17.5 mm 54 mm 17.5 mmMounting DIN rail DIN rail DIN railWidth 1 module 3 modules 1 moduleConnection Screw terminals Plug-in terminals Screw terminalsAmbient temperature -25 °C to +50 °C -30 °C to +55 °C -30 °C to +55 °CSensor temperature range -25 °C to +50 °C -30 °C to +55 °C -40 °C to +70 °CDegree of protection IP20, Sensor IP 54 IP20, Sensor IP 55 IP20, Sensor IP 55Protection class II II IICertifi cation mark V V VMax. line length to the sensor 25 m 100 m 25 m

NEWPHASE OUT PHASE OUT

1.82Controlling & Switching

Surface-Mounted Light Intensity Switch SRSW1NOW

82 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Surface-Mounted Light Intensity Switch SRSW1NOW

• Twilight switch with an integrated light sensor• Cable entry is possible at the rear or from the bottom• Large terminal area• Setting the brightness value is possible from outside, without the need to open

the device • Wide angle of light incidence (approx. 180°)

• Transparent cover: High exposure to light • Selectable Lux range button: 2 - 100 lux / 100 - 2000 lux• Brightness Teach-in button: set current brightness value directly • Timer function button: switch on light for 1 hour timer• Manual operation button: switch on/off light until next sensor switch off/on event• Switch-on and switch-off delay can be adjusted

Technical Data

Connection diagram Dimensions (mm)SRSW1NO / SRSW1NOW

SRSW1NO SRSW1NOWElectricalRated operational voltage 220–230 V AC 230 V AC, +10%/-15%Frequency 50-60 Hz 50–60 HzStand-by Power (typical) 0.6 W 0.7 WSetting range for brightness 2-2000 lx I: 2–100 lx; II: 100–2000 lxPreset brightness value 15 lx 15 lxSwitch-on/off delay 2-100 s 2-100 sContact type NO NOSwitch output Not potential-free (230 V) Not potential-free (230 V)Switching capacity

at 250 V AC, cos = 1 16 A 16 Aat 230 V AC, cos = 0.3 10 AX 10 AX

Min. switching capacity - 10 mA/230V ACIncandescent/halogen lamp load 2300 W 2300 WEnergy saving lamps 9 x 7 W, 7 x 11 W, 7 x 15 W,

7 x 20 W, 7 x 23 WLED lamp < 2 W 20 W 50 WLED lamp 2-8 W 55 W 600 WLED lamp > 2 W 70 W 600 WFluorescent lamp load (conventional)

not corrected 2300 VA 2300 VAseries corrected 2300 VA 2300 VAparallel corrected 400 VA 42 μF 1300 VA, 130 μF

Fluorescent lamp (electronic ballast) 1100 WCompact fl uorescent lamp (electronic ballast) 300 WMechanicalHight 118.4 mm 118.4 mmWidth 85 mm 85 mmDepth 49.4 mm 49.4 mmMounting Wall mounted Wall mountedConnection Screw terminals Screw terminalsAmbient temperature -35 °C to +55 °C -35 °C to +55 °CDegree of protection IP 55 IP 55Protection class II IICertifi cation mark V V

NEWPHASE OUT

SRSW1NO / SRSW1NOW

1.83

83 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingLight Intensity Switch with Timer for DIN Rail SRCD1CO

Description Light Intensity Switch with Timer for DIN Rail SRCD1CO

• Twilight switch with an integrated weekly timer• External light sensor included in delivery• 1 channel• External input• 3 special programs (small annual program)• Pulse program• 84 memory locations• Switching brightness digitally adjustable• Adjustable On and Off switching delay• Switching brightness and switching delay can be set separately for switching On and Off• Onscreen display of channel and switching status as well as current lux value

• Zero-cross switching for relay-saving switching and high lamp loads• Up to 4 sensors can be attached• Up to 10 devices can be connected to a digital sensor• Extended brightness range• Permanent switching ON/OFF• Test function• Switching preselection• Display back light (can be turned off)• PIN coding• Operating hour counter• DuoFix spring terminals

Connection diagram Dimensions (mm)

Technical DataSRCD1CO SRCD1COD

ElectricalRated operational voltage 220–240 V AC 110 – 230 V AC, +10%/-15%Frequency 50–60 Hz 50 – 60 HzStand-by Power (typical) 1.3 W 0.8 WPower reserve 10 years at 20 °C 10 years at 20 °CSetting range for brightness 2–2000 lx 1 – 99000 lxPreset brightness value 15 lxSwitch-on/off delay 0 – 59 min 0 – 59 minNumber of channels 1 1Number of memory locations 56 84External inputs 0 1Accuracy (typical) ± 0.5 s/day (quartz) ± 0,25 s/day at 25 °C (quartz)Keyboards 4 touch buttons, 1 potentiometer 4 touch buttonsShortest switching times 1 min 1 minContact type Changeover contact Changeover contactSwitching output Potential-free, not suitable for SELV Switching of any external conductor is permittedSwitching capacity

at 230 V AC, cos = 1 16 A 16 Aat 230 V AC, cos = 0.6 10 A 10 A

Incandescent/halogen lamp load 2600 W 2600 WFluorescent lamp load (conventional)

not corrected 2300 VA 2600 VAseries corrected 800 VA (80 μF) 1300 VA (130 μF)parallel corrected 650 VA 1100 W

Energy saving lamps 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 WLED lamp < 2 W 50 WLED lamp > 2 W 600 WMechanicalFrame size 45 mm 45 mmDevice width 54 mm 36 mmMounting DIN rail DIN railWidth 3 modules 2 modulesType of connection DuoFix spring terminals DuoFix spring terminalsAmbient temperature -30 to +55 °C -25°C ... 55°C, sensor -40 °C ... +70 °CType of protection IP 20, sensor IP 55 IP 20, sensor IP 55Protection class II, Sensor III II, Sensor IIIMax. cable length to sensor 100 m 100 m

NEWPHASE OUT

SRCD1CO SRCD1CODSRCD1CO SRCD1COD

Ext1

ma

x.

10

0 m

ma

x.

10

0 m

Data

Lux

- +

1.84Controlling & Switching

Control Relay EASY xSystem, Multifunction display MFD xSystem

84 EATON CORPORATION xxxxx+xxxx-xxxxEN

Inputs Outputs TypeDesignation

Article No. Units perpackage

Control Relay EASYwa_sg03211, wa_sg02511

8 x 230 V AC 4 x Relay 8A EASY512-AC-RC 274104 112 x 230 V AC 6 x Relay 8A EASY719-AC-RC 274115 112 x 230 V AC 6 x Relay 8A EASY819-AC-RC 256267 1

230 V AC, display

wa_sg02811, wa_sg02611

8 x 24 V DC 4 x Relay 8A EASY512-DC-RC 274109 18 x 24 V DC 4 x Transistor EASY512-DC-TC 274111 112 x 24 V DC 6 x Relay 8A EASY719-DC-RC 274119 112 x 24 V DC 8 x Transistor EASY721-DC-TC 274121 112 x 24 V DC 6 x Relay 8A EASY819-DC-RC 256269 112 x 24 V DC 8 x Transistor EASY821-DC-TC 256273 1

24 V DC, display, analog Value Processing

Multifunction display MFDwa_sg02411

LCD-display, 80 mm, with keys MFD-80-B 265251 1CPU power supply for MFD, AC MFD-AC-CP8-NT 274092 1230V inputs, relay outputs MFD-AC-R16 274093 1

230 V AC, Graphical display, Degree of protection IP66

wa_sg0241124 V DC, Graphical display, Degree of protection IP66

Function TypeDesignation

Article No. Units perpackage

LCD-display, 80 mm, with keys MFD-80-B 265251 1CPU power supply for MFD, DC MFD-CP8-NT 265253 1Inputs 24 V DC, relay outputs MFD-R16 265254 1Inputs 24 V DC, transistor outputs MFD-T16 265255 1Inputs 24 V DC, relay outputs, analog MFD-RA17 265364 1Inputs 24 V DC, transistor outputs, analog MFD-TA17 265256 1

Accessories for EASY and MFD Operating and programming software EASY-SOFT-BASIC 284545 1

Operating and programming software incl. graphic editor EASY-SOFT-PRO 266040 1USB-PC programming cable easy400 to easy700 EASY-USB-CAB 107926 1USB-PC programming cable easy800 and multifunction display

EASY800-USB-CAB 106408 1

Power supply, 24 V DC, 0,2 A EASY200-POW 229424 1Power supply, 24 V DC, 1,25 A EASY400-POW 212319 1Power supply, 24 V DC, 2,5 A EASY500-POW 110941 1

1.85

85 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingControl Relay EASY xSystem

Technical Data

EASY512-.. EASY7.. EASY8..ElectricalStandards and regulations EN 55011, EN 55022, EN 6100-4, IEC 60068-2-6, IEC 60068-2-27Dimensions (B x H x T) 71.5 x 90 x 58 mm (4TE) 107.5 x 90 x 72 mm (6TE) 107.5 x 90 x 72 mm (6TE)Weight 0.2 kg 0.3 kg 0.3 kgMounting DIN rail IEC/EN 60715, 35 mm or screw-mounting with device stands ZB4-101-GF1

(accessory)

Terminal capacitysolid 0.2/4 mm2 (AWG 22-12) 0.2/4 mm2 (AWG 22-12) 0.2/4 mm2 (AWG 22-12)fi ne wires with wire end sleeve 0.2/2.5 mm2 (AWG 22-12) 0.2/2.5 mm2 (AWG 22-12) 0.2/2.5 mm2 (AWG 22-12)Slotted screwdriver 3.5 x 0.8 mm 3.5 x 0.8 mm 3.5 x 0.8 mmMax. tightening torque 0.6 Nm 0.6 Nm 0.6 NmClimatic environmental conditionsAmbient temperature of operation -25 to +55 °C, cold according to IEC 60068-2-1, heat according to IEC 60068-2-2Exposure to dew to be avoided through appropriate measuresLCD-display (clear reading) 0 to +55 °C 0 to +55 °C 0 to +55 °CStorage -40 to +70 °C -40 to +70 °C -40 to +70 °CRelative humidity, no exposure to dew (IEC/EN 60068-2-30) 5 - 95% 5 - 95% 5 - 95%Atmospheric pressure (operation) 795 - 1080 hPa 795 - 1080 hPa 795 - 1080 hPaCorrosion resistance

IEC/EN 60068-2-42 - 4 days SO2 10 cm3/m3 10 cm3/m3 10 cm3/m3

IEC/EN 60068-2-43 - 4 days H2S 1 cm3/m3 1 cm3/m3 1 cm3/m3

Mechanical environmental conditionsPollution degree 2 2 2Degree of protection (IEC/EN 60529) IP20 IP20 IP20Vibrations (IEC/EN 60068-2-6)

Constant amplitude 0.15 mm 10 - 57 Hz 10 - 57 Hz 10 - 57 HzConstant acceleration 2 g 57 - 150 Hz 57 - 150 Hz 57 - 150 Hz

Shock resistance (IEC/EN 60068-2-27) half-sinusoidal 15 g / 11 ms 18 shocks 18 shocks 18 shocksTipping over (IEC/EN 60068-2-31), height of fall 50 mm 50 mm 50 mmFree fall, packaged (IEC/EN 60068-2-32) 1 m 1 m 1 mOperation position horizontal/vertical horizontal/vertical horizontal/vertical

Dimensions (mm)

90 102

110

71.5

M4

10.75 50

35.75

EASY512-.. EASY7..

EASY8..

45

58

56.5

47.5

4.5

90 102

110

M4

107.5

75 16.2516.2545

58

56.5

47.5

4.5

90 102

110

M4

107.5

75 16.2516.25

45

72

70.5

48.5

4.5

1.86Controlling & Switching

Multifunction display MFD xSystem

86 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical Data

MFD-80..ElectricalStandards and regulations EN 61000-6-1/-2/-3/-4, IEC 60068-2-6, IEC 60068-2-27Dimensions (B x H x T) 86.5 x 86.5 x 21.5 mm (with keys), 86.5 x 86.5 x 20 mm (without keys)Weight 0.13 kgMounting 2 x 22.5 mm, display fi xed with 2 fastening ringsClimatic environmental conditionsAmbient temperature of operation -25 to +55 °C, cold according to IEC 60068-2-1, heat according to IEC 60068-2-2Exposure to dew to be avoided through appropriate measuresLCD-display (clear reading) -5 to +50 °C, -10 to 0 °C with background light switched on (permanent operation)Storage -40 to +70 °CRelative humidity, no exposure to dew (IEC/EN 60068-2-30) 5 - 95%Atmospheric pressure (operation) 795 - 1080 hPaCorrosion resistance

IEC/EN 60068-2-42 - 4 days SO2 10 cm3/m3

IEC/EN 60068-2-43 - 4 days H2S 1 cm3/m3

Mechanical environmental conditionsPollution degree 3Degree of protection (IEC/EN 60529) IP65Vibrations (IEC/EN 60068-2-6)

Constant amplitude 0.15 mm 10 - 57 HzConstant acceleration 2 g 57 - 150 Hz

Shock resistance (IEC/EN 60068-2-27) half-sinusoidal 15 g / 11 ms 18 shocksTipping over (IEC/EN 60068-2-31), height of fall 50 mmFree fall, packaged (IEC/EN 60068-2-32) 1 mOperation position horizontal/vertical

Dimensions (mm)

90

88.2

107.5

20 43.2

33.7

MFD-80..

1.87

87 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingSignalling Devices AS

Function Rated voltage(V~)

TypeDesignation

Article No. Units perpackage

Bell 230 V AC ASBELL230 167393 1Bell 12 V AC ASBELL12 167394 1Buzzer 230 V AC ASBUZZ230 167395 1Siren 24 V AC/DC ASSIR24 167396 1

Signalling Devices ASwa_sg04311

ASBELL230

Technical DataASBELL230, ASBUZZ230 ASBELL12

ElectricalStandards IEC 62080 IEC 62080Rated operational voltage Ue 230 V AC 12 V ACRated operational power Ps 5.5 VA 4 VAWorking range 50/60 Hz 0.94 ... 1.06 x Uc 0.94 ... 1.06 x Uc

Rated frequency 50 Hz 50 HzWorking range of frequency 45 ... 65 Hz 45 ... 65 HzRated power loss in idle operation Pv 0.83 W 0.83 WPollution degree according to EN 61010-1 2 2Operating voltage according to EN 61010-1 230 V AC 12 V ACInsulating material group according to EN 61010-1 II IISafe separation

Air gap 3 mm 1.5 mmCreep distance within the device 2.5 mm 1.5 mm

Test voltage 50 Hz, 1 min. 1.25 kV 1 kVFlammability class V0 V0Terminal capacity

solid 1 x 6 or 2 x 4 mm2 1 x 6 or 2 x 4 mm2

fl exible with wire end sleeve, min. 0.75 mm2 0.75 mm2

Sound volume 75 dB 75 dBPermitted ambient temperature -10 to +55 °C -10 to +55 °CDegree of protection according to DIN EN 60529 IP20, with angeschlossenen wiresn IP20, with angeschlossenen wiresnProtection class according to DIN EN 61140 / VDE 0140 II II

Description Bell ASBELL, Buzzer ASBUZZ230

• Signal bells and buzzers are typically used in residential buildings and in functional buildings such as shops, offi ces, banks etc. They are either used to signalize alert conditions, or generally as audible sound signals.

• These devices are built-in devices installed in distribution cabinets. They are designed for short-time operation in compliance with the IEC 62080 standard.• Space-saving design of one module unit only. • Safe device protection thanks to PTC to avoid overloads and short-circuits.

Connection diagramASBELL ASBUZZ230

Dimensions (mm)

1.88Controlling & Switching

Signalling Devices AS

88 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical Data Siren ASSIR24ASSIR24

ElectricalData according to EN 60669-1Feed voltage 24 V AC/DCVoltage tolerance range ± 15%Power loss 2.4 VAVoltage test AC 2.5 kVSound volume 105 dBOperative temperature -10 to +55 °CStorage temperature -25 to +70 °CDegree of protection IP20

Dimensions (mm)

1.89

89 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingBell-Transformers 230 V, TR-G

MU Secondary voltage(V)

Secondary current(A)

TypeDesignation

Article No. Units perpackage

2 8 1 TR-G/8 272480 1 / 282 4-8-12 1-1-0.67 TR-G3/8 272481 1 / 282 8 1 TR-G/8-S 272482 1 / 282 4-8-12 2-2-1.5 TR-G3/18 272483 1 / 283 12-24 2-1 TR-G2/24 272484 1 / 20

Bell-Transformers 230 V, TR-GSG82911

Technical DataTR-G/8 TR-G3/8 TR-G/8-S TR-G3/18 TR-G2/24

Electrical

Nominal power 8 VA 8 VA 8 VA 18 VA 24 VARated supply voltage range 230-240 V AC 230-240 V AC 230-240 V AC 230-240 V AC 230-240 V AC

at terminals 5-8 5-8 5-8 5-8 5-8Rated frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 HzNo-load current 25 mA 26 mA 25 mA 36 mA 24 mARated supply current 69 mA 58 mA 69 mA 72/124/138 mA 155/160 mAPrimary resistance 616 667 616 229 616 Rated output voltage 8 V AC 4/8/12 V AC 8 V AC 4/8/12 V AC 12/24 V AC

at terminals 1-3 2-3/1-2/1-3 1-3 2-3/1-2/1-3 1-2/1-3No-load output voltage 13 V 4.9/12/16.8 V 13 V 5.9/12/17.8 V 16/31 VRated output voltage 8.4 V 3.8/7.9/12.2 V 8.4 V 4.3/8.4/12.7 V 12.2/23.2 V

at rated output current 1 A 1-1-0.67 A 1 A 2-2-1.5 A 2-1 ASecondary resistance 2 0.9/1.9/2.8 2 0.4/1/1.3 1/3 Power loss in no-load operation 1.4 W 1.4 W 1.4 W 1.8 W 1.9 WTotal power loss at nominal load 7.1 W 6.2 W 7.1 W 11.6 W 11.9 WShort circuit proof PTC PTC PTC PTC PTCTest voltage (primary-secondary) 5 kV 5 kV 5 kV 5 kV 5 kVPollution degree P2 P2 P2 P2 P2MechanicalFrame size 45 mm 45 mm 45 mm 45 mm 45 mmDevice height 90 mm 90 mm 90 mm 90 mm 90 mmDevice width 36 mm 36 mm 36 mm 36 mm 54 mmWeight 236 g 253 g 236 g 354 g 612 gMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP20 IP20 IP20 IP20 IP20Upper and lower terminals lift terminals lift terminals lift terminals lift terminals lift terminalsTerminal capacity 1 - 3x2.5 mm2 1 - 3x2.5 mm2 1 - 3x2.5 mm2 1 - 3x2.5 mm2 1 - 3x2.5 mm2

Tightening torque of terminal screws 0.5 Nm 0.5 Nm 0.5 Nm 0.5 Nm 0.5 NmPermitted relative air humidity <95% <95% <95% <95% <95%Rated ambient temperature 40 °C 40 °C 40 °C 40 °C 35 °CTemperature rise at intermittent duty (20 x 1 min. 100% and 5 min. 20%) 24 K 24 K 24 K 26 K 31 KInsulation class E E E E EGlow wire-test enclosure 850 °C 850 °C 850 °C 850 °C 850 °C

Description Bell-Transformers 230 V, TR-G

• Type -S with primary switch• Accessories: Suface Mounting Set (mounting plate, terminal covers)

Connection diagram (e.g.)TR-G/8 TR-G/8-S Bell transformer

Short circuit-proof trans-former

1.90Controlling & Switching

Bell-Transformers 230 V, TR-G

90 EATON CORPORATION xxxxx+xxxx-xxxxEN

Dimensions (mm)

1.91

91 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingSafety-Transformer 230 V, TR-G2/63-SF

MU Secondary voltage(V)

Secondary current(A)

TypeDesignation

Article No. Units perpackage

5 12-24 5.2-2.6 TR-G2/63-SF 272485 1 / 12

Safety-Transformer 230V, TR-G2/63-SFSG42512

Technical DataTR-G2/63-SF

Electrical

Nominal power 63 VARated supply voltage range 230-240 V AC

at terminals 7-12Rated frequency 50 HzNo-load current 60 mARated supply current 340 mAPrimary resistance 41 Rated output voltage 12/24 V AC

at terminals 1-4/1-4 (terminal connection)No-load output voltage 13.6/27.3 VRated output voltage 12/24.1 V

at rated output current 5.2-2.6 ASecondary resistance 0.15/0.6 Power loss in no-load operation 4.1 WTotal power loss at nominal load 19.6 WDuty 100%Short circuit proof inherently (PTC)Test voltage (primary-secondary) 5 kVPollution degree P2MechanicalFrame size 45 mmDevice height 90 mmDevice width 90 mmWeight 1256 gMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP20Upper and lower terminals lift terminalsTerminal capacity 1 - 3x2.5 mm2

Tightening torque of terminal screws 0.5 NmPermitted relative air humidity <95%Rated ambient temperature 25 °CTemperature rise at uninterrupted duty 51 KInsulation class FGlow wire-test enclosure 850 °C

Description Safety-Transformer 230V, TR-G2/63-SF

• 100% duty• Safety transformer with separate windings according to EN 61558• Accessories: Suface Mounting Set (mounting plate, terminal covers)

Connection diagram (e.g.)TR-G2/63-SF Safety transformer according to EN 61558

(Fail-safe = no danger in case of failure)

Short circuit-proof trans-former

terminal connection

1.92Controlling & Switching

Safety-Transformer 230 V, TR-G2/63-SF

92 EATON CORPORATION xxxxx+xxxx-xxxxEN

Dimensions (mm)

1.93

93 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingCommand and Signalling Devices RMQ Titan® xCommand

Command and Signalling Devices RMQ Titan® xCommand

Description TypeDesignation

Article No. Units perpackage

wa_sg00912 spring-return, black M22-D-S-K11 SET000001 1spring-return, white M22-D-W-K11 SET000002 1spring-return, red M22-D-R-K11 SET000003 1spring-return, green M22-D-G-K11 SET000004 1spring-return, gelb M22-D-Y-K11 SET000005 1spring-return, blue M22-D-B-K11 SET000006 1stay-put, black M22-DR-S-K11 SET000007 1stay-put, white M22-DR-W-K11 SET000008 1stay-put, red M22-DR-R-K11 SET000009 1stay-put, green M22-DR-G-K11 SET000010 1stay-put, gelb M22-DR-Y-K11 SET000011 1stay-put, blue M22-DR-B-K11 SET000012 1

• Complete units for front installation

Push-button, fl at, 1NO+1NC

wa_sg00912 spring-return, white M22-DL-W-K11-230-W SET000013 1spring-return, red M22-DL-R-K11-230-R SET000014 1spring-return, green M22-DL-G-K11-230-G SET000015 1spring-return, gelb M22-DL-Y-K11-230-W SET000016 1spring-return, blue M22-DL-B-K11-230-B SET000017 1stay-put, white M22-DRL-W-K11-230-W SET000018 1stay-put, red M22-DRL-R-K11-230-R SET000019 1stay-put, green M22-DRL-G-K11-230-G SET000020 1stay-put, gelb M22-DRL-Y-K11-230-W SET000021 1stay-put, blue m22-DRL-B-K11-230-B SET000022 1

Push-button, fl at, LED 230 V, 1NO+1NC

wa_sg00612 white M22-L-W-230-W SET000023 1red M22-L-R-230-R SET000024 1green M22-L-G-230-G SET000025 1gelb M22-L-Y-230-W SET000026 1blue M22-L-B-230-B SET000027 1

Indicator lamp, fl at, LED 230 V

wa_sg00712 2 positions, spring-return M22-WK-K11 SET000028 12 positions, stay-put M22-WRK-K11 216519 1

Selector, 1NO+1NC

wa_sg00812 2 positions, spring-return M22-WS-K11 SET000029 12 positions, stay-put M22-WRS-K11 216517 1

Key-operated switch, 1NO+1NC

1.94Controlling & Switching

Command and Signalling Devices RMQ Titan® xCommand

94 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description TypeDesignation

Article No. Units perpackage

wa_sg01012 Double push-button 1NO+1NC with LED

I

0

M22-DDL-GR-X1/X0/K11/230-W 216509 1

Double push-button, 1NO+1NC with LED

Accessories RMQ Titan®

SG06410 DIN rail adapter M22-IVS 216400 1Contact element 1NO M22-K10 216376 20Contact element 1NC M22-K01 216378 20

wa_sg02911 Emergency switch-off button, 2NC, surface-mounted M22-PV/KC02/IY 216524 1

EMERGENCY SWITCH-OFF button, complete unit IP66

1.95

95 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingCommand and Signalling Devices RMQ Titan® xCommand

Technical Data Command and Signalling Devices RMQ Titan® xCommand

Contact elements LED elements1) Luminous push-buttonPush-button

GeneralStandards and regulations IEC/EN 60947, VDE 0660Endurance, mechanical components > 5 x 106 switching op. – > 5 x 106 switching op.Operating frequency 3600 switching op./h – 3600 switching op./hOperating force 5 N – 5 NOperating torque (Screw-type terminals) 0.8 Nm – –Degree of protection IEC/EN 60529 IP20 IP20 IP67, IP69KResistance to climatic conditions2) Humidity and heat, constant, according to IEC 60068-2-78

Humidity and heat, periodic, according to IEC 60068-2-30Ambient temperature1), open -25 to +70 °C -25 to +70 °C -25 to +70 °COperation position as required as required as requiredShock resistance according to IEC 60068-2-27, Shock duration 11 ms, half-sinusoidal > 30 g > 30 g > 30 gTerminal capacity

solid 0.75 - 2.5 mm2 0.75 - 2.5 mm2 –multi-wire 0.5 - 2.5 mm2 0.75 - 2.5 mm2 –

Current pathsRated peak withstand voltage Uimp 6000 V AC 6000 V AC –Rated insulation voltage Ui 500 V 500 V –Overvoltage category/Pollution degree III/3 III/3 –Circuit safety HF

at 24 V DC / 5 mA < 10-7 failure rate, < 1 failure to 107 switching operations

– –

at 5 V DC / 1 mA < 5 x 10-6 failure rate, < 1 failure to 5 x 106 swit-ching operations

– –

Max. short-circuit protectionWithout fuse PKZM0-10 / PLSM-B6 – –Fuse gG/gL 10 A – –

Switching capacityRated operational current Ie

AC-15115 V 6 A – –120 V 6 A – –400 V 4 A – –500 V 2 A – –DC-1324 V 3 A – –42 V 1.7 A – –60 V 1.2 A – –110 V 0.8 A – –220 V 0.3 A – –

Endurance, electrical componentsAC-15230 V / 0.5 A 1.6 x 106 switching operations – –230 V / 1 A 1 x 106 switching operations – –230 V / 3 A 0.7 x 106 switching operations – –DC-1312 V / 2.8 A 1.2 x 106 switching operations – –

1) > 200 V AC / 60 Hz: -25 to +55 °C2) Indoor and protected outdoor position

Dimensions (mm)Indicator lamp M22-L... Selector M22-W.K... Push-buttons M22-D... Key-operated buttons M22-W.S...

11.5 26.9 10

47.75

20.6

o 2

9.7

37

4530

Installation depth

1.96Controlling & Switching

Command and Signalling Devices LS-TITAN® xCommand

96 EATON CORPORATION xxxxx+xxxx-xxxxEN

Command and Signalling Devices LS-TITAN® xCommand

Description TypeDesignation

Article No. Units perpackage

wa_sg03111 Cap plunger head LS-11 266109 10Roller plunger LS-11/P 266112 2Spring-rod head, snap-action switch LS-11S/S 266104 2Roller lever LS-11/L 266110 2Rotary lever LS-11/RL 266111 2Adjustable roller lever LS-11/RLA 266113 2Actuating lever, snap-action switch LS-11S/RR 266106 4

• NO, 1 NC

Position switch LS-11, IP66

Technical Data Command and Signalling Devices LS-TITAN® xCommand

Position switch LS-11GeneralStandards and regulations IEC/EN 60947Resistance to climatic conditions Humidity and heat, constant, according to IEC 60068-2-78

Humidity and heat, periodic, according to IEC 60068-2-30Ambient temperature -25 to +70 °COperation position as requiredTerminal capacity Cage-Clamp1)

solid 1 x (0.5-2.5) mm2

fi ne wires with wire end sleeve according to DIN 46228 1 x (0.5-1.5) mm2

Current paths/Switching capacityRated peak withstand voltage Uimp 4000 V ACRated insulation voltage Ui 500 VOvervoltage category/Pollution degree III/3Circuit safety HF

at 24 V DC / 5 mA < 10-7 failure rate, < 1 failure to 107 switching operationsat 5 V DC / 1 mA < 5 x 10-6 failure rate, < 1 failure to 5 x 106 switching operations

Rated operational current IeAC-1524 V 6 A230/240 V 6 A400/415 V 4 ADC-1324 V 10 A110 V 1 A220 V 0.5 A

Line frequency max. 400 HzShort-circuit resistance when closed (IEC/EN 60947-5-1)

Without fuse PKZM0-10 / PLSM-B6max. Fuse gG/gL 10 A

Short-circuit current strength IEC/EN 60947-5-1, max. Fuse gG/gL 6 AMechanical specifi cationsEndurance

Standard-action switch 8 x 106 switching operationsSnap-action switch 8 x 106 switching operations

Contact temperature of the actuating roller 100 °CShock resistance (half-sinusoidal shock 20 ms)

Standard-action switch 25 gSnap-action switch 2 gBasic device –

Operating frequency 6000 switching operations/h

1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, D-32423 Minden

1.97

97 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingCommand and Signalling Devices LS-TITAN® xCommand

Dimensions (without actuation element) in mm

5.3

31

55

8.2

21

a

11.7

12.5

14

33.5

76

222025

4.3

4.3

507.

3

b

o 4

1.95

M20

Position switch LS-11...

1.98Controlling & Switching

Contactors DILM, DILA, ZB xStart

98 EATON CORPORATION xxxxx+xxxx-xxxxEN

Contactors DILM

Rated current (A)

Rated power (kW)

Auxiliary contact TypeDesignation

Article No. Units perpackage

wa_sg00111

7 3 1NC DILM7-10(230V50HZ) 276550 17 3 1NC DILM7-01(230V50HZ) 276585 16 4 1NC DILM9-10(230V50HZ) 276690 16 4 1NC DILM9-01(230V50HZ) 276725 112 5.5 1NC DILM12-10(230V50HZ) 276830 112 5.5 1NC DILM12-01(230V50HZ) 276865 117 7.5 1NC DILM17-10(230V50HZ) 277004 117 7.5 1NC DILM17-01(230V50HZ) 277036 125 11 1NC DILM25-10(230V50HZ) 277132 125 11 1NC DILM25-01(230V50HZ) 277164 132 15 1NC DILM32-10(230V50HZ) 277260 132 15 1NC DILM32-01(230V50HZ) 277292 140 18.5 – DILM40(230V50HZ) 277766 150 22 – DILM50(230V50HZ) 277830 165 30 – DILM65(230V50HZ) 277894 1

Control Voltage 230 V 50 Hz, 240 V 60 Hz

wa_sg00111

7 3 1NC DILM7-10(24VDC) 276565 17 3 1NC DILM7-01(24VDC) 276600 16 4 1NC DILM9-10(24VDC) 276705 16 4 1NC DILM9-01(24VDC) 276740 112 5.5 1NC DILM12-10(24VDC) 276845 112 5.5 1NC DILM12-01(24VDC) 276880 117 7.5 1NC DILM17-10(RDC24) 277018 117 7.5 1NC DILM17-01(RDC24) 277050 125 11 1NC DILM25-10(RDC24) 277146 125 11 1NC DILM25-01(RDC24) 277178 132 15 1NC DILM32-10(RDC24) 277274 132 15 1NC DILM32-01(RDC24) 277306 140 18.5 – DILM40(RDC24) 277780 150 22 – DILM50(RDC24) 277844 165 30 – DILM65(RDC24) 277908 1

Control Voltage 24 VDC

Motor-protective Relay ZB

Overload release setting range(A)

TypeDesignation

Article No. Units perpackage

wa_sg17604

0.1 - 0.16 ZB12-0.16 278431 10.16 - 0.25 ZB12-0.24 278432 10.25 - 0.4 ZB12-0.4 278433 10.4 - 0.63 ZB12-0.6 278434 10.63 - 1 ZB12-1 278435 11 - 1.6 ZB12-1.6 278436 11.6 - 2.5 ZB12-2.4 278437 12.5 - 4 ZB12-4 278438 14 - 6,3 ZB12-6 278439 16.3 - 10 ZB12-10 278440 110 - 12 ZB12-12 278441 112 - 16 ZB32-16 278452 116 - 24 ZB32-24 278453 124 - 32 ZB32-32 278454 1

Suitable for DILM7 to DILM32

1.99

99 EATON CORPORATION xxxxx+xxxx-xxxxEN

Controlling & SwitchingContactors DILM, DILA, ZB xStart

Overload release setting range(A)

TypeDesignation

Article No. Units perpackage

wa_sg17704

6 -10 ZB65-10 278455 110 - 16 ZB65-16 278456 116 - 24 ZB65-24 278457 124 - 40 ZB65-40 278458 140 - 57 ZB65-57 278459 150 -65 ZB65-65 278460 1

Suitable for DILM40 to DILM65

Auxiliary Switch moduless DILA-XHI

NO NC TypeDesignation

Article No. Units perpackage

wa_sg17404

2 – DILA-XHI20 276422 51 1 DILA-XHI11 276421 54 – DILA-XHI40 276428 53 1 DILA-XHI31 276427 52 2 DILA-XHI22 276426 5

Suitable for DILM7 to DILM32

Auxiliary Switch moduless DILM150-XHIwa_sg03011

2 – DILM150-XHI20 277945 51 1 DILM150-XHI11 277946 54 – DILM150-XHI40 277948 53 1 DILM150-XHI31 277949 52 2 DILM150-XHI22 277950 5

Suitable for DILM40 to DILM65

1.100Controlling & Switching

Contactors DILM, DILA, ZB xStart

100 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical Data Contactors xStart

DILM, DILA, ZBGeneralStandards and regulations IEC/EN 60947, VDE 0660, UL, CSAEndurance, mechanical components

AC operated 10 x 106 switching operationsDC operated 10 x 106 switching operations

Switching frequency, mechanical componentsAC operated 9000 switching operations/hDC operated 9000 switching operations/h

Resistance to climatic conditions Humidity and heat, constant, according to IEC 60068-2-78Humidity and heat, periodic, according to IEC 60068-2-30

Ambient temperatureopen -25 to +60 °Chermetically enclosed -25 to +40 °Cstorage -40 to +80 °C

Mounting position AC and DC operated

Shock resistance (half-sinusoidal shock 10 ms) (IEC/EN 60068-2-27)Main switching elements NO 10 gAuxiliary switching elements NO 7 gAuxiliary switching elements NC 5 g

Degree of protection IP20Protection against accidental contact in case of vertical actuation from the front fi nger and hand touch safe according to DGUV VS3, EN 50274Main current pathsRated peak withstand voltage Uimp 8000 V ACRated insulation voltage Ui 690 VOvervoltage category/Pollution degree III/3Rated operational voltage Ue 690 VSafe separation according to VDE 0106 Part 101 and Part 101/A1

between coil and contacts 400 V ACbetween the contacts 400 V AC

Making capacity cos according to IEC/EN 60947 to 690 V 112 A

Dimensions (mm)

6.9

4.734.4

113.8

132.1

146.75

55

57 86.4

104

Contactors DILM7-DILM12 Contactors DILM17-DILM32

6.9

4.734.4

113.8

132.1

146.75

55

57 86.4

104

Contactors DILM40-DILM65

4583

65

48

35.5

39.5

29.5

Motor-protective Relay ZB12, ZB32

1.101

101 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar Systems

SG13113 sg03515

wa_sg03511 Wa_sg02902

1.102Busbar Systems

Busbar System xEffect BB-EV

102 EATON CORPORATION xxxxx+xxxx-xxxxEN

SG13113

Busbar System xEffect is the modular design

system for busbars. xEffect busbars are avail-

able as yard goods with 1, 2 or 3 poles. Now,

there is a special feature: each bar can easily

be extended by one-pole bar as you like. The

additional pole can be added completely with-

out tools by easy clamping technique. The lugs

or forks in the xEffect bars - available in 10 and

16 mm2 and all common distances - can be

broken out at a predetermined breaking point.

There is actually no more fl exibility available.

Busbar System xEffect saves time and material

The yard good can be cut with a saw of course.

However, there is no need neither for deburring

nor for cutting the conductor. Just cut to the

required dimension and close with the fi tting

end cap -ready! The end caps have also break-

able edges, which enable further connecting

of the busbar System xEffect. By overlapping

assembly, doubling the cross section can be

achieved.

Busbar System xEffect in use

Busbar System xEffect is especially well suited

for solving fl exible busbar applications rack-

mounted models in series. Fork-pin combina-

tions for 1+N-applications can be realized

by individual combinations - for this also the

one-pole version with blue isolation is available

besides the one with grey isolation. Even dif-

ferent cross sections can be combined in this

case.

Accessories, such as feeder terminals and self

adhesive phase marking labels will complete

the comfortable total package. Existing contact

prevention caps can be used.

Busbar System xEffect at a glance:

• Yard goods can be cut

• No cutting back of copper required

• No deburring required

• Almost no waste during cutting

• End capsavailable with 1- to 4-poles, end caps

can be broken out for further extensions

• 4-pole end cap molded in pairs (leftand right)

• Overlapping rail extension possible

• Rails can be extended on demand by 1-pole

rails (plug-in technology)

• All step distances

• 10 and 16 mm2

• Fork and stud

• Lugs can be broken out at any predetermined

breaking point

• Self adhesive phase indication labels avail-

able

• Contact preventing caps (ZV-BS-G) can be

used

• Simple, fl exible handling

• All assembly requirements can be covered by

the busbar System xEffect

• Low storage space requirements due to

modular system

• Less time consuming (no deburring, no cutting

back)

• Individual and self confi gurable

• Fork-pin combination for 1+N application pos-

sible, feeding through rail (terminal clamp) not

possible.

• Protected technology

Description

1.103

103 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsxEffect busbar 1m 10mm2, 16mm2 (Fork) BB-EVF

For MCBs, RCCBs, RCBOs, SPDs

SG13113

1-phase 17.8 0.22 BB-EVF-10/1P-1MU 168826 1027 0.24 BB-EVF-10/1P-1,5MU 168830 1036 0.24 BB-EVF-10/1P-2MU 168834 10

2-phases 17.8 0.31 BB-EVF-10/2P-1MU 168838 1027 0.36 BB-EVF-10/2P-1,5MU 168840 10

3-phases 17.8 0.46 BB-EVF-10/3P-1MU 168842 1027 0.58 BB-EVF-10/3P-1,5MU 168844 1036 0.56 BB-EVF-10/3P-2MU 168850 10

3-phases + AUX 3x17.8+1x9 0.58 BB-EVF-10/3P-1MU/AUX 168846 103x17.8+2x9 0.57 BB-EVF-10/3P-1MU/2AUX 168848 10

Neutral 17.8 0.22 BB-EVF-10/N-1MU 168828 1027 0.24 BB-EVF-10/N-1,5MU 168832 1036 0.24 BB-EVF-10/N-2MU 168836 10

Description Step Distance Cu-factor Type Article No. Units per(mm) Designation package

10 mm2, Rated current 63 A

• delivered without end caps

SG13413

SG13213

1-phase 17.8 0.33 BB-EVF-16/1P-1MU 168827 1027 0.36 BB-EVF-16/1P-1,5MU 168831 1036 0.32 BB-EVF-16/1P-2MU 168835 10

2-phases 17.8 0.46 BB-EVF-16/2P-1MU 168839 1027 0.54 BB-EVF-16/2P-1,5MU 168841 10

3-phases 17.8 0.69 BB-EVF-16/3P-1MU 168843 1027 0.87 BB-EVF-16/3P-1,5MU 168845 1036 0.84 BB-EVF-16/3P-2MU 168851 10

3-phases + AUX 3x17.8+1x9 0.87 BB-EVF-16/3P-1MU/AUX 168847 103x17.8+2x9 0.86 BB-EVF-16/3P-1MU/2AUX 168849 10

Neutral 17.8 0.33 BB-EVF-16/N-1MU 168829 1027 0.36 BB-EVF-16/N-1,5MU 168833 1036 0.32 BB-EVF-16/N-2MU 168837 10

16 mm2, Rated current 80 A

SG13613

1.104Busbar Systems

xEffect busbar 1m 10mm2, 16mm2 (Fork) BB-EVF

104 EATON CORPORATION xxxxx+xxxx-xxxxEN

For MCBs, RCCBs, RCBOs, SPDs

SG13113

1-phase 17.8 0.22 BB-EVP-10/1P-1MU 168852 1027 0.24 BB-EVP-10/1P-1,5MU 168856 1036 0.24 BB-EVP-10/1P-2MU 168860 10

2-phases 17.8 0.31 BB-EVP-10/2P-1MU 168864 1027 0.36 BB-EVP-10/2P-1,5MU 168866 10

3-phases 17.8 0.46 BB-EVP-10/3P-1MU 168868 1027 0.58 BB-EVP-10/3P-1,5MU 168870 1036 0.56 BB-EVP-10/3P-2MU 168876 10

3-phases + AUX 3x17.8+1x9 0.58 BB-EVP-10/3P-1MU/AUX 168872 103x17.8+2x9 0.57 BB-EVP-10/3P-1MU/2AUX 168874 10

Neutral 17.8 0.22 BB-EVP-10/N-1MU 168854 1027 0.24 BB-EVP-10/N-1,5MU 168858 1036 0.24 BB-EVP-10/N-2MU 168862 10

10 mm2, Rated current 63 A

• delivered without end caps

SG13413

SG13213

1-phase 17.8 0.33 BB-EVP-16/1P-1MU 168853 1027 0.36 BB-EVP-16/1P-1,5MU 168857 1036 0.32 BB-EVP-16/1P-2MU 168861 10

2-phases 17.8 0.46 BB-EVP-16/2P-1MU 168865 1027 0.54 BB-EVP-16/2P-1,5MU 168867 10

3-phases 17.8 0.69 BB-EVP-16/3P-1MU 168869 1027 0.87 BB-EVP-16/3P-1,5MU 168871 1036 0.84 BB-EVP-16/3P-2MU 168877 10

3-phases + AUX 3x17.8+1x9 0.87 BB-EVP-16/3P-1MU/AUX 168873 103x17.8+2x9 0.86 BB-EVP-16/3P-1MU/2AUX 168875 10

Neutral 17.8 0.33 BB-EVP-16/N-1MU 168855 1027 0.36 BB-EVP-16/N-1,5MU 168859 1036 0.32 BB-EVP-16/N-2 MU 168863 10

16 mm2, Rated current 80 A

SG13613

Description Step Distance Cu-factor Type Article No. Units per(mm) Designation package

Accessories

End Caps BB-EV-ECwa_sg05612 1-phase - - BB-EV-EC/1P 168878 40

2+3-phases - - BB-EV-EC/2-3P 168823 404-phases - - BB-EV-EC/4P 168824 20Neutral - - BB-EV-EC/N 168879 20

Terminal BB-EV-MU/35wa_sg05312 - - 0.04 BB-EV-MU/35 168825 3

Sticker Phase SequenceSG08713 - - BB-S-PS 169831 5

Busbar Tag Shrouds ZV-BS-GSG05705 - - ZV-BS-G 104903 10/600

1.105

105 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsxEffect busbar 1m 10mm2, 16mm2 (Fork) BB-EVF

Technical DataBB-EV.

GeneralHeat defl ection temperature 80°C UL94 V0Standards EN 60947-1:2007 / IEC 60947-1:2007 / IEC 60999:2000Climate stability according to DIN EN 60068Insulation coordination Overvoltage category III / Pollution degree 2ElectricalImpulse voltage strenght 4.5 kVMin. air distance >5.5 mmMin. creeping distance >5 mmMax. operating voltage 690 V AC/DC

1,000 V DC 1-pole onlyMax. busbar current Is/Phase

10 mm2 63 A16 mm2 80 A

Protection class IP20Short circuit rating ICC 25 kA - NH3 355A, gC500V JMDielectric strenght PC - ABS >32 kV / mm

Assembly instruction:Cutting

Mounting of an extension busbar

Overlapping mounting or further connection, resp.

Brecking out of connection lugs Sticking on phase marking

1.106Busbar Systems

Plug-in busbar System 50 A, 80 A ZV

106 EATON CORPORATION xxxxx+xxxx-xxxxEN

Plug-in busbar System 50 A, 80 A ZV

wa_sg02618

End caps ZV-AEKBusbar cover ZV-ADPBusbarZV-SSZV-SS-80A

for PLS., CLS., PKN., PFIM, PFHM (with Auxiliary Switch)

Description Cu-factor TypeDesignation

Article No. Units perpackage

Connection Angle L1, NWA_SG08102

10 units 0.005 ZV-L1/N-10 263941 10 / 60036 units 0.005 ZV-L1/N-36 263942 36 / 2160100 units 0.005 ZV-L1/N-100 263943 100 / 3000

50 A

L1L1

NN

Same connection angle ZV-L1/N (-80A), for L1 and N, turned by 180°

10 units 0.005 ZV-L1/N-80A-10 263950 10 / 60036 units 0.005 ZV-L1/N-80A-36 263951 36 / 2160100 units 0.005 ZV-L1/N-80A-100 263952 100 / 3000

80 A

Connection Angle L2, L3WA_SG07902

10 units 0.007 ZV-L2/L3-10 263944 10 / 60036 units 0.007 ZV-L2/L3-36 263945 36 / 2160100 units 0.007 ZV-L2/L3-100 263946 100 / 3000

50 A

Same connection angle ZV-L2/L3(-80A), for L2 and L3, turned by 180°

10 units 0.007 ZV-L2/L3-80A-10 263953 10 / 60036 units 0.007 ZV-L2/L3-80A-36 263954 36 / 2160100 units 0.007 ZV-L2/L3-80A-100 263955 100 / 3000

80 AL2L2

L3L3

Connection Angle N (0.5 MU) for PLSM, CLS6 with 1.5 MUWA_SG08002

10 units 0.005 ZV-N-05TE-10 263947 10 / 60036 units 0.005 ZV-N-05TE-36 263948 36 / 2160

50 A

Same connection angle ZV-N-05TE for N (CLS6 with 1.5TE) 50 and 80 A busbar

100 units 0.005 ZV-N-05TE-100 263949 100 / 3000

80 A

NN

Busbar 1m330607, SG7997

0.143 ZV-SS 263956 1 / 10

50 A

0.230 ZV-SS-80A 263957 1 / 10

80 A

50 A, ZV-SS 80 A, ZV-SS-80A

1.107

107 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsPlug-in busbar System 50 A, 80 A ZV

Accessories Busbar cover 1m, for 50+80 A ZV-ADP 263958 1 / 10

End caps for busbar cover ZV-AEK 263959 10 / 600Power feed block 35/50mm2 Z-D80 248269 12 / 120

Description TypeDesignation

Article No. Units perpackage

1.108Busbar Systems

Plug-in busbar System 50 A, 80 A ZV

108 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Plug-in busbar System 50 A, 80 A ZV

• Any combinations of switchgear with or without auxiliary switch possible• Low number of components, 2 angle types per busbar cross-section for three-phases AC• Same busbar cover and end caps for ZV-SS and ZV-SS-80A• Short-circuit withstand strength and dielectric properties tested according to IEC/EN 60439-1

Technical Data

ZVElectricalRated operational voltage 240/415 VA CRated frequency 50/60 Hz, DCRated voltage 690 V (at Pollution degree 2)

440 V (at Pollution degree 3)Overvoltage category IIIRated peak withstand voltage Uimp 4 kVRated current

ZV-./., ZV-SS 50 AZV-./.-80A, ZV-SS-80A 80 AZV..-N-05TE 32 A

Conditional rated short circuit currentAC with 125 A gGZV-./., ZV-SS 50 kAZV-./.-80A, ZV-SS-80A 50 kAZV..-N-05TE 10 kAAC with 160 A gGZV-./., ZV-SS –ZV-./.-80A, ZV-SS-80A 50 kAZV..-N-05TE 10 kADC with 160 A gGZV-./., ZV-SS 10 kAZV-./.-80A, ZV-SS-80A 10 kAZV..-N-05TE –

MechanicalBusbar cross section

ZV-SS 16 mm2 CuZV-SS-80A 25 mm2 Cu

Busbar length 1 mDegree of protection mounted with busbar cover and end caps IP20Pollution degree 2 (3)Air gap 3.2 mmMinimum creepage distance 7 mm

Connection diagram

Dimensions (mm) 50 A Dimensions (mm) 80 A

1.109

109 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Fork) Z-GV

Busbar Block (Fork) Z-GV

Description Cu-factor TypeDesignation

Article No. Units perpackage

sg03515

1-phase 16x 0.095 Z-GV-16/1P-1MU/16 271074 502-phases 8x 0.187 Z-GV-16/1P+N-2MU/16 271075 204-phases 4x 0.444 Z-GV-16/3P+N-4MU/16 271078 15

16 mm2 - Rated current 80 A

• for PXL, PXK, PXF, PLS., CLS., PKN., PFIM, PFHM, Z-SLS/D01

Busbar Block (Fork) Z-GV• delivered with end caps

sg03515

1-phase 0.408 Z-GV-10/1P-1MU 270339 503-phases 0.739 Z-GV-10/3P-3MU 271060 203-phases 0.739 Z-GV-10/3P-4MU 271080 20End cap 1-phase Z-V-AK/1P 104905 10 / 600End cap 2+3-phases BB-EC/2+3P 120805 10 / 600

10 mm2 - Rated current 63 A

Busbar Block (Fork) Z-GV, 1 Meter• delivered without end caps

1-phase 0.470 Z-GV-16/1P-1MU 271061 501-phase + Auxiliary Switch 0.470 Z-GV-16/1P+HS 271062 502-phases 0.657 Z-GV-16/1P+N-2MU 271063 203-phases 1.042 Z-GV-16/3P-3MU 271064 203-phases + Auxiliary Switch 0.998 Z-GV-16/3P+HS 271065 204-phases 1.465 Z-GV-16/3P+N-4MU 271066 154-phases 1.522 Z-GV-16/3P+3N-6MU 263142 154-phases 1.050 Z-GV-16/PKPX/4PHAS 116882 10End cap 1-phase Z-V-AK/1P 104905 10 / 600End cap 2+3-phases BB-EC/2+3P 120805 10 / 600End cap 4-phases Z-V-AK/4P 264931 10 / 600

16 mm2 - Rated current 80 A

Accessories

Busbar Tag Shrouds for busbar, yellow ZV-BS-GSG05705 Finger and hand touch safe ZV-BS-G 104903 10/600

Description TypeDesignation

Article No. Units perpackage

1.110Busbar Systems

Busbar Block (Fork) Z-GV

110 EATON CORPORATION xxxxx+xxxx-xxxxEN

Devices to busbar Pcs. of the devices End caps Type

Description of the Busbar Block (Fork) Z-GV

1-phase

2-phases

3-phases

4-phases

For 2-pole Combined RCD/MCB Device, 3-phases

1-phase + Auxiliary Switch

3-phases + Auxiliary Switch

For 2-pole Combined RCD/MCB Device, 4-phases

1.111

111 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Fork) Z-GV

Description Busbar Block 10mm2, 16mm2 (Fork) Z-GV

• Length 1m• Delivered without end caps. Please order separately.• Short version (/17, /16, /8) delivered with end caps

Technical DataZ-GV

ElectricalRated voltage 240/415 V, 50/60 HzRated current

10 mm2 63 A16 mm2 80 A

Short-circuit current strength 25 kAMechanicalBusbar cross section 10 and 16 mm2 CuStep distance 17.8 mm

Z-GV-16-.P+HS 17.8/27 mm

Connection diagram

Dimensions (mm)

1.112Busbar Systems

Busbar Block (Fork and Pin) Z-GSV

112 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar Block (Fork and Pin) Z-GSV

Description Cu-factor TypeDesignation

Article No. Units perpackage

wa_sg01611

4-phases 0.208 Z-GSV-10/FI+EH+2XLS1N 113138 104-phases 0.277 Z-GSV-10/FI+EH+4XLS1N 113139 10

10 mm2 - Rated current 63 A

• for PLS.1N (1.5MU)

Busbar Block (Fork and Pin) Z-GSV• delivered with end caps

wa_sg01611

2-phases 0.585 Z-GSV-16/1P+N 271067 104-phases 1.840 Z-GSV-16/3P+3N 271068 104-phases 2.196 Z-GSV-16/FI+EH+KR+30XLS1N 113137 7End cap 4-phases Z-V-AK/4P 264931 10 / 600

16 mm2 - Rated current 80 A

Busbar Block (Fork and Pin) Z-GSV, 1 Meter• delivered without end caps

2-phases 9x 0.179 Z-GSV-16/1P+N/9 271077 154-phases 3x 0.408 Z-GSV-16/3P+3N/9 271079 15

16 mm2 - Rated current 80 A

Description of the Busbar Block (Fork and Pin) Z-GSV

Devices to busbar Pcs. of the devices End caps Type

2-phases

4-phases

4-phases

4-phases

4-phases

PHASE OUT

1.113

113 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Fork and Pin) Z-GSV

Description Busbar Block 10mm2, 16mm2 (Fork and Pin) Z-GSV

• Length 1m• Delivered without end caps. Please order separately.• Short version (/9) delivered with end caps

Technical DataZ-GSV

ElectricalRated voltage 240/415 V, 50/60 HzRated current

10 mm2 63 A16 mm2 80 A

Short-circuit current strength 25 kAMechanicalBusbar cross section 10 and 16 mm2 CuStep distance 26.7 mm

Connection diagram

Dimensions (mm)

1.114Busbar Systems

Busbar Block (Pin) Z-SV...-SD, 1 Meter

114 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar Block (Pin) Z-SV...-SD, 1 Meter

Description Cu-factor TypeDesignation

Article No. Units perpackage

• For Protected Earth Socket Z-SD230• delivered with end caps

2-phases 0.588 Z-SV-10/1P+N-SD 269526 10End caps Z-V-AK/2+3P 264930 10 / 600

10 mm2 - Rated current 50 A

Description Busbar Block 10mm2 (Pin) Z-SV ...-SD

• Delivered without end caps• Step (distance between two pins of identical phase, i. e. L or N) 2.5 MU• Length 1 m

Technical DataZ-SV-10/1P+N-SD

ElectricalRated voltage 230/400 V, 50/60 HzRated current 50 AShort-circuit current strength 25 kAMechanicalBusbar cross section 10 mm2 CuStep distance 44 mm

Connection diagram

AccessoriesWA_SG10602

End caps

WA_SG10702

Extension terminal Z-EK/25/QL

WA_SG10702

Extension terminal Z-EK/25

1.115

115 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Pin) Z-SV

Busbar Block (Pin) Z-SV

Description Cu-factor TypeDesignation

Article No. Units perpackage

WA_SG11302

1-phase straight grey 0.055 Z-SV-10/1P-1MU/13 264916 101-phase straight blue 0.055 Z-SV-10/N-1MU/13 264917 101-phase angulated grey 0.055 Z-SV-10/1P-F/13 264918 101-phase angulated blue 0.055 Z-SV-10/N-F/13 264919 102-phases 0.126 Z-SV-10/2P-2MU/13 264922 103-phases 0.203 Z-SV-10/3P-3TE/13 264924 104-phases 0.258 Z-SV-10/3P+N-4TE/12 264926 104-phases (for PLN.) 0.258 Z-SV-10/3P+3N-3TE/13 264927 10

10 mm2 - Rated current 50 A

• for PLN. (1MU), Z-SI

Busbar Block (Pin) Z-SV, 13TE• delivered with end caps

WA_SG11302

1-phase straight grey 0.385 Z-SV-16/1P-1MU 264912 251-phase straight blue 0.385 Z-SV-16/N-1MU 264913 251-phase angulated grey 0.385 Z-SV-16/1P-1MU/F 269523 251-phase angulated blue 0.385 Z-SV-16/N-1MU/F 269524 252-phases 0.941 Z-SV-16/2P-2MU 264923 103-phases (for PLN.) 1.326 Z-SV-16/2P+2N-2MU 264914 73-phases 1.422 Z-SV-16/3P-3TE 264925 104-phases 2.177 Z-SV-16/3P+N-4TE 264928 74-phases (for PLN.) 1.807 Z-SV-16/3P+3N-3TE 264915 7

16 mm2 - Rated current 63 A

Busbar Block (Pin) Z-SV, 1 Meter• delivered without end caps

Accessories

Busbar Tag Shrouds for busbar, yellow ZV-BS-GSG05705 Finger and hand touch safe ZV-BS-G 104903 10/600

Description TypeDesignation

Article No. Units perpackage

End caps, Z-V-AK/, Z-BB-EC/4Pwa_sg05413 1-phase Z-V-AK/1P 104905 10 / 600

2+3-phases Z-V-AK/2+3P 264930 10 / 6004-phases Z-BB-EC/4P 1) 183116 10 / 6001) only for Z-SV-16/3P+N-4TE, Article No. 264928

Extension terminals 6 - 25 mm2, Z-EK/25wa_sg02512 long, straight Z-EK/25 264935 10 / 600

short, straight Z-EK/25/K 269525 10 / 600long, crosswise Z-EK/25/QL 264937 10 / 600short, crosswise Z-EK/25/Q 264936 10 / 600

1.116Busbar Systems

Busbar Block (Pin) Z-SV

116 EATON CORPORATION xxxxx+xxxx-xxxxEN

Devices to busbar Pcs. of the devices End caps Type

Description of the Busbar Block (Pin) Z-SV

Example

L3L1

Z-SV-10/1P-F/13, Z-SV-16/1P-1TE/FZ-SV-10/N-F/13, Z-SV-16/N-1TE/F

58

98

L N

62

102

L N

Z-SV-.. 2-phasig bis 4-phasig

73

113

L2 N

76

116

L1 L2 L3 N

Extension terminal Z-EK/25/QL

Extension terminal Z-EK/25

Extension terminal Z-EK/25/Q

Extension terminal Z-EK/25/K

1-phase + 2-phases

2-phases

3-phases

4-phases

1.117

117 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Pin) Z-SV

Description Busbar Block 10mm2 (Pin) Z-SV-10/, 16mm2 (Pin) Z-SV-16/

• Busbar Block 10 mm2 delivered with end caps, length 13TE• Busbar Block 16 mm2 without end caps, length 1m

Technical DataZ-SV

ElectricalRated voltage 240/415 V, 50/60 HzRated current

10 mm2 50 A16 mm2 63 A

Short-circuit current strength 25 kAMechanicalBusbar cross section 10 and 16 mm2 CuStep distance 17.80 mm

Connection diagramZ-SV-../3P+N-3TE..

AccessoriesSG4800

End caps

WA_SG10702

Extension terminal Z-EK/25/QL

WA_SG10702

Extension terminal Z-EK/25

WA_SG10702

Extension terminal Z-EK/25/Q

SG07703

Extension terminal Z-EK/25/K

1.118Busbar Systems

Busbar Block 12MU (Fork and Pin) Z-GSV-10

118 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar Block 12MU (Fork and Pin) Z-GSV-10

Description Cu-factor TypeDesignation

Article No. Units perpackage

SG4700

below2-phases, RCD-2p + 4xPLN 0.07 Z-GSV-10/1P+N-NL/6 274297 10 / 2002-phases, RCD-2p + 10xPLN 0.131 Z-GSV-10/1P+N/12-U 274299 10 / 1004-phases, RCD-4p + 4xPLN 0.13 Z-GSV-10/3P+N-NL/8 116858 104-phases, RCD-4p + 8xPLN 0.463 Z-GSV-10/3P+N/12-U 274400 10 / 1004-phases, RCD-4p + 3xPLS.. + 5xPLN 0.463 Z-GSV-10/3P+N/12H-U 274401 10 / 100

above2-phases, RCD-2p + 10xPLN 0.131 Z-GSV-10/1P+N/12-O 274402 10 / 1004-phases, RCD-4p + 8xPLN 0.463 Z-GSV-10/3P+N/12-O 274403 10 / 100

10 mm2 - Rated current 50 A

• for PLN. (1MU) + FI• delivered with end caps

Description of the Busbar Block 12MU (Fork and Pin) Z-GSV-10

Devices to busbar Pcs. of the devices End caps Type

2-phases

4-phases

1.119

119 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block 12MU (Fork and Pin) Z-GSV-10

Description Busbar Block 12MU 10mm2 (Fork and Pin) Z-GSV-10

• 12MU busbar elements incl. end caps

Technical DataZ-GSV-10

ElectricalRated voltage 240/415 V, 50/60 HzRated current 50 AShort-circuit current strength 25 kAMechanicalBusbar cross section 10 mm2 CuStep distance 17.95 mm

Connection diagram

Z-GSV-10/3P+N/12-O

AccessoriesWA_SG10702

Extension terminal Z-EK/25/QL

WA_SG10702

Extension terminal Z-EK/25

1.120Busbar Systems

Busbar Block 13MU (Fork and Pin) Z-GSV-10

120 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar Block 13MU (Fork and Pin) Z-GSV-10

Description Cu-factor TypeDesignation

Article No. Units perpackage

wa_sg14303

above2-phases, RCD-2p + 11xPLG 0.251 Z-GSV-10/1P+N-F/13 264920 10

10 mm2 - Rated current 63 A

• for 1x RCD + PLG. (1MU)

• Do not cut!!

Accessories

Busbar Tag Shrouds for busbar, yellow ZV-BS-GSG05705 Finger and hand touch safe ZV-BS-G 104903 10/600

Description TypeDesignation

Article No. Units perpackage

Extension terminals 6 - 25 mm2, Z-EK/25wa_sg02512 long, straight Z-EK/25 264935 10 / 600

long, crosswise Z-EK/25/QL 264937 10 / 600

Description of the Busbar Block 13MU (Fork and Pin) Z-GSV-10

N NL L N L N L N L N L N L N L N L N L N L N L Z-GSV-10/1P+N-F/13

2-phasig x11

Devices to busbar Pcs. of the devices Type

Description Busbar Block 13MU 10mm2 (Fork and Pin) Z-GSV-10

• 13MU busbar elements without end caps

Technical DataZ-GSV-10

ElectricalRated voltage 240/415 V, 50/60 HzRated current 63 AShort-circuit current strength 25 kAMechanicalBusbar cross section 10 mm2 CuStep distance 17.95 mm

Connection diagram

Z-GSV-10/3P+N-F/13

AccessoriesWA_SG10602

End caps

WA_SG10702

Extension terminal Z-EK/25/QL

WA_SG10702

Extension terminal Z-EK/25

2-phases

1.121

121 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Pin) Z-SV-../1P+N-F

Busbar Block (Pin) Z-SV-../1P+N-F

Description Cu-factor TypeDesignation

Article No. Units perpackage

SG07106

PFGC + 4x PLGC 0.105 Z-SV-10/1P+N-F/6 107944 10 / 100PFGC + 7x PLGC 0.155 Z-SV-10/1P+N-F/9 107943 10 / 100PFGC + 11x PLGC 0.22 Z-SV-10/1P+N-F/13 107942 10 / 100

10 mm2 - Rated current 50 A

• for 1x PFGC + PLGC. (1MU)• 2-phases

• Do not cut!!

PFGC + 4x PLGC 0.155 Z-SV-16/1P+N-F/6 191245 10 / 100PFGC + 7x PLGC 0.231 Z-SV-16/1P+N-F/9 191244 10 / 100PFGC + 8x PLGC 0.259 Z-SV-16/1P+N-F/10 191246 10 / 100PFGC + 11x PLGC 0.328 Z-SV-16/1P+N-F/13 191243 10 / 100

16 mm2 - Rated current 63 A

Accessories

Busbar Tag Shrouds for busbar, yellow ZV-BS-GSG05705 Finger and hand touch safe ZV-BS-G 104903 10/600

Description TypeDesignation

Article No. Units perpackage

Description of the Busbar Block (Pin) Z-SV-../1P+N-F

Devices to busbar Pcs. of the devices Type

Description Busbar Block 10/16mm2 (Pin) Z-SV-../1P+N-F

• Busbar elements without end caps

2-phases

1.122Busbar Systems

Busbar Block (Pin) Z-SV-../1P+N-F

122 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical DataZ-SV-../1P+N-F

ElectricalRated voltage 240/415 V, 50/60 HzRated current

10 mm2 50 A16 mm2 63 A

Overvoltage category IIIRated peak withstand voltage Uimp 4 kVConditional rated short circuit current AC with 125 A gG 10 kAMechanicalBusbar cross section 10 and 16 mm2 CuStep distance 17.8 mmFlame class according to UL94 V0, glowing wire test 960 °CPollution degree 2Comparative tracking index CTI 300Air gap 5.5 mmMinimum creepage distance 5 mm

Dimensions (mm)

Z-SV-10/1P+N-F/6, Z-SV-16/1P+N-F/6

Z-SV-10/1P+N-F/9, Z-SV-16/1P+N-F/9

Z-SV-16/1P+N-F/10

Z-SV-10/1P+N-F/13, Z-SV-16/1P+N-F/13

Connection diagram

1.123

123 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar UL489 Z-SV/UL16

• For MCB FAZ-NA/RT

• 16 mm2

• Pin busbar

• Accessories available:

Terminals

Busbar tag shrouds

• Several length

Description

wa_sg03511

1.124Busbar Systems

Busbar UL489 Z-SV/UL16

124 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description of UL489-Busbar

Devices to busbar Pcs. of the devices Type

For FAZ-NA/RT, not sliceable!!

wa_sg03511

1-phase, 6MU 17.6 0.035 Z-SV/UL-16/1P-1TE/6 104892 101-phase, 12MU 17.6 0.07 Z-SV/UL-16/1P-1TE/12 104893 101-phase, 18MU 17.6 0.105 Z-SV/UL-16/1P-1TE/18 104894 102-phase, 6MU 17.6 0.07 Z-SV/UL-16/2P-2TE/6 104895 102-phase, 12MU 17.6 0.14 Z-SV/UL-16/2P-2TE/12 104896 102-phase, 18MU 17.6 0.21 Z-SV/UL-16/2P-2TE/18 104897 103-phase, 6MU 17.6 0.14 Z-SV/UL-16/3P-3TE/6 104898 103-phase, 12MU 17.6 0.221 Z-SV/UL-16/3P-3TE/12 104899 103-phase, 18MU 17.6 0.332 Z-SV/UL-16/3P-3TE/18 104900 10

Description Step Distance Cu-factor Type Article No. Units per(mm) Designation package

16 mm2, Rated current 80 A

• Delivered with end caps

Accessories

TerminalsSG07506 2,5 - 35mm2 - 0.035 Z-EK/35/UL 104901 3

1,5 - 50mm2 - 0.038 Z-EB/50/UL 104902 3

Busbar Tag ShroudsSG07706 for 3 pins - - ZV-BS-UL 104904 10

2-phases

1-phase

3-phases

1.125

125 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar UL489 Z-SV/UL16

Connection diagram

Z-SV/UL-16/3P-3TE Z-SV/UL-16/2P-2MU Z-SV/UL-16/1P-1MU

Description of the Busbar UL489 Z-SV/UL-16 for FAZ-NA/RT

Technical DataZ-SV/UL16

GeneralHeat defl ection temperature 125°C - UL94 V0Standards

Busbar UL489, DIN EN 60947-1, VDE 0660 Teil 100 = IEC 60947-1:2004, IEC 60947-2:2003Terminal IEC 60999:2000, UL489, UL486A, CSA C22.2

Climate stability according to DIN EN 60068Insulation coordination Overvoltage category III / Pollution degree 2ElectricalImpulse voltage strenght 9.5 kV (1 kV / mmLS)Min. air distance > 9.5 mm/25.4 mm (proprietary/external)Min. creeping distance > 12.7 mm/50.8 mm (proprietary/external)Max. operating voltage

1-, 3-phase 690 V IEC480Y/277V & 240 V AC

Terminals 1.000 V AC/DCMax. busbar current Is/Phase 80 AProtection class IP20Short circuit rating 15 kA mit NH3 355 A gL 500 V JM / 7.5 kA 3 cycles @ 600 VDielectric strenght >30 kV/mm

Article No.104892 Z-SV/UL-16/1P-1TE/6 6 - -104893 Z-SV/UL-16/1P-1TE/12 12 - -104894 Z-SV/UL-16/1P-1TE/18 18 - -104895 Z-SV/UL-16/2P-2TE/6 - 3 -104896 Z-SV/UL-16/2P-2TE/12 - 6 -104897 Z-SV/UL-16/2P-2TE/18 - 9 -104898 Z-SV/UL-16/3P-3TE/6 - - 2104899 Z-SV/UL-16/3P-3TE/12 - - 4104900 Z-SV/UL-16/3P-3TE/18 - - 6104901 Z-EK/35/UL - - -104902 Z-EB/50/UL - - -104904 ZV-BS-UL - - -

1.126Busbar Systems

Busbar UL489 Z-SV/UL16

126 EATON CORPORATION xxxxx+xxxx-xxxxEN

Mounting example of busbar UL489 Z-SV/UL-16 for FAZ-NA/RT

ATTENTION: Maximum of 3 commoning linksallowed. Any combination of same pole confi guration.ATTENTION: 3 liaisons communes autorisées au maximum.Toute combinaison de confi gurations de polarité identiques.ACHTUNG: Maximal 3 Schienenblöcke. Beliebige Kombination gleichpoliger Konfi gurationen.ATTENZIONE: Sono consentiti al massimo 3 pettini di collegamento in qualsiasi combinazione della stessa confi gurazione di poli.ATEÖION: Se permite un máximo de 3 enlaces comunes.Cualquier combinación del mismo tipo de confi guración de polo

ATTENTION: Do not cut.ATTENTION: Ne pas couper.ACHTUNG: Nicht durchschneiden.ATTENZIONE: Non tagliare.ATEÖION: No corte.

UL489 EN/IEC 60947-2

Ue 480 V AC 96 V DC 240/415 V ACf 50/60 Hz — 50/60 HzUimp — 9,5 kVIe 80 A @ 40°C 80 A @ 30°CTerminal capacity — 16 mm2

UL489 EN/IEC 60947-2

Ue 480 V AC 96 V DC 240/415 V ACf 50/60 Hz — 50/60 HzUimp — 9,5 kV

UL489 EN/IEC 60947-2

Ue 480 V AC 96 V DC 240/415 V ACf 50/60 Hz — 50/60 HzUimp — 9,5 kV

Z-EB/50/UL Z-EK/35/UL

Cross section:U - single wire K - fi ne wire (with

sleeve)Torque

R - multi wire F - fi ne wire (with sleeve)

Max. cross section 50 mm2

1 AWG copper wire35 mm2

2 AWG copper wire4 Nm35 lbf.in

Min. cross section 1,5 mm2

14 AWG copper wire

Busbar-side Pin max. 5,5x2 / 0.2“x0.07“Länge min. 12,7 mm / Length min. 0.5“

2,5 Nm22 lbf.in

Cross section:U - single wire K - fi ne wire (with

sleeve)Torque

R - multi wire F - fi ne wire (with sleeve)

Max. cross section 35 mm2

2 AWG copper wire5,5 Nm50 lbf.in

Min. cross section 2,5 mm2

14 AWG copper wire

1.127

127 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar UL489 Z-SV/UL16

Z2

FAZ-NA

FAZ-RT

ZV-BS-UL

Z-EK/35/UL

4 mm

IEC/EN 60947-2 Icc

UL SCCR

Ue V AC

Z-SV/ULIcc A

240/415 15000

FAZ-NAFAZ-RTInA

UeV AC

Z-SV/ULSCCR RMSSym A

0.5-32 480Y/277 1000035-40 240 10000

AWG Ib-in Nm14 21 2.312-8 25 2.86-2 36 4.0

Dimensions (mm)

Z-SV/UL-16/.TE/6 Z-SV/UL-16/.TE/12

Z-SV/UL-16/.TE/18

ZV-BS-UL

Z-EK/35/UL

Mounting example of busbar UL489 Z-SV/UL-16 for FAZ-NA/RT

1.128Busbar Systems

Busbar UL489 Z-SV/UL16

128 EATON CORPORATION xxxxx+xxxx-xxxxEN

Example Z-EK/35/UL

UL489 IEC/EN60947-2# 2-14 AWG60/75 °C Cu

2.5-35 mm2

Cu

0.56 in 14 mm

testet acc. to Tightening torqueUL486A # 14 AWG 2.3 NmUL486B # 8-12 AWG 2.8 NmUL486E # 6-1 AWG 4 Nm

1.129

129 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Pin) Z-SV

Busbar Block (Pin) Z-SV

Description Cu-factor TypeDesignation

Article No. Units perpackage

wa_sg03611

3-phases 0.84 Z-SV-16/3P 271072 20

16 mm2 - Rated current 80 A

• delivered without end caps

Busbar Block (Pin) Z-SV-16/3P• for Z-SLS, PLHT, D0.-SO/.. (1.5MU)

Accessories for Z-SV-16/3P

Extension terminalwa_sg05913 Extension terminal 6-50 mm2 Z-EK/50 264934 3 / 180

End capSG4800 End cap Z-V-35/AK/3P 264932 10 / 600

1-phase angulated grey 0.83 Z-SV-35/1P 113135 13-phases 2.74 Z-SV-35/3P 264938 43-phases 2.74 Z-SV-35/PLHT-V 264939 44-phases* 1.57 Z-SV-35/3P+N-6TE 263110 4* delivered with end caps

35 mm2 - Rated current 110 A

Busbar Block (Pin) Z-SV-35• for Z-SLS, PLHT, D0.-SO/.. (1.5MU), PLHT-V (1.5MU)

Accessories for Z-SV-35

End capSG4800 End cap Z-V-35/AK/3P 264932 10 / 600

wa_sg03711

Accessories for Z-SV-35

Extension terminals Z-EK/95

wa_sg05513 for Z-SV-35/1P Z-EK/95-1 113136 3 / 90for Z-SV-... 3-phases Z-EK/95 264933 3 / 90for Z-SV-35/3P+N Z-EK/95-3N 264911 4 / 120

• 25-95 mm2 single-/multi-wire• 16-70 mm2 fi ne wires with wire end sleeve

1.130Busbar Systems

Busbar Block (Pin) Z-SV

130 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description of the Busbar Block (Pin) Z-SV

Devices to busbar Pcs. of the devices End caps Type

Description Busbar Block (Pin) Z-SV

• End caps are to be ordered separately, exception Z-SV-35/3P+N-6TE• Halogenfree plastic

Technical DataZ-SV-16 Z-SV-35

ElectricalRated operational voltage 240/415 V AC 240/415 V ACRated frequency 50/60 Hz 50/60 HzRated voltage 500 V 690 VOvervoltage category III IIIRated peak withstand voltage Uimp 4 kV 6 kVRated current 80 A 110 AConditional rated short circuit current AC with 250 A gG 50 kAr.m.s. 100 kAr.m.s.

MechanicalBusbar cross section 16 mm2 Cu 35 mm2 CuStep distance 27 mm 27 mm (Z-SV-35/PLHT-V 30.5 mm)Flame class according to UL94 V0, glowing wire test 960 °C V0, glowing wire test 850 °CDegree of protection, with end caps IP20 IP20Pollution degree 2 2Comparative tracking index CTI 300 CTI 600Air gap 5 mm 4.3 mmMinimum creepage distance 10.2 mm 6.7 mm

3-phases

4-phases

1-phase

1.131

131 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsBusbar Block (Pin) Z-SV

Dimensions (mm)

Z-SV-35/3P+N-6TE

Z-SV-35/1P

Extension terminal Z-EK/50

Accessories for Z-SV-35

Wa_sg10802

Extension terminalnZ-EK/95, Z-EK/95-3N, Z-EK/95-1

Wa_sg10802

Accessories for Z-SV-16

n A B C D E F G H IZ-SV-16/3P 35 27 5 945 971 14.9 31 1.5 17 19Z-SV-35/3P 35 27 8.5 945 1000 19.7 38.4 2.5 21.5 23.9Z-SV-35/PLHT-V 32 30.5 8.5 976 1000 19.7 38.4 2.5 21.5 23.9

1.132Busbar Systems

Euro-Vario-Busbar (Fork) EVG

132 EATON CORPORATION xxxxx+xxxx-xxxxEN

Euro-Vario-Busbar (Fork) EVG

Phases MU Cu-factor TypeDesignation

Article No. Units perpackage

Wa_sg02902

1-phase 2 0.015 EVG-1PHAS/2MODUL 215646 40 / 8001-phase 6 0.039 EVG-1PHAS/6MODUL 215638 40 / 8001-phase 12 0.075 EVG-1PHAS/12MODUL 215637 40 / 4002-phases 4 0.051 EVG-2PHAS/4MODUL 268220 20 / 4002-phases 6 0.079 EVG-2PHAS/6MODUL 215642 20 / 4002-phases 12 0.150 EVG-2PHAS/12MODUL 215641 20 / 2003-phases 6 0.086 EVG-3PHAS/6MODUL 215640 20 / 4003-phases 9 0.128 EVG-3PHAS/9MODUL 215645 20 / 2003-phases 12 0.168 EVG-3PHAS/12MODUL 215639 20 / 2003-phases 16 0.230 EVG-3PHAS/16MODUL 285381 203-phases 20 0.310 EVG-3PHAS/20MODUL 285383 20 / 1804-phases 16 0.320 EVG-3P+3N/16MODUL 105215 204-phases 18 0.350 EVG-3P+3N/18MODUL 274161 204-phases 8 0.219 EVG-4PHAS/8MODUL 215644 10 / 1004-phases 12 0.324 EVG-4PHAS/12MODUL 215643 10 / 100

1- to 4-phases

• for PLS., CLS., PKN., PFIM, PFHM, PFNM• no end caps necessary

• Do not cut!!

10 mm2 - Rated current 63 A

1-phase 2-5 0.045 EVG-1PHAS/N/2-5MODUL/FILS 285384 40 / 800

For 2-pole Combined RCD/MCB Device with a width of 3MU

3-phases 4+5 0.138 EVG-3PHAS/N/5MODUL/LS 215659 20 / 2003-phases 4+8 0.188 EVG-3PHAS/N/8MODUL/LS 215660 20 / 200

For combination RCD/MCBs with RCD 4-pole

Wa_sg01602

1-phase 2.5 0.025 EVG-1PHAS/2MODUL/HI 215655 40 / 2001-phase 13 0.096 EVG-1PHAS/9MODUL/HI 215656 402-phases 4.5 0.053 EVG-2PHAS/4MODUL/HI 219573 20 / 4002-phases 12 0.160 EVG-2PHAS/10MODUL/HI 215657 203-phases 6.5 0.100 EVG-3PHAS/6MODUL/HI 216411 20 / 2003-phases 13.5 0.200 EVG-3PHAS/12MODUL/HI 215658 20

For applications with Auxiliary Switch

Wa_sg02902

1-phase 2 0.023 EVG-16/1PHAS/2MODUL 291464 40 / 8001-phase 6 0.059 EVG-16/1PHAS/6MODUL 291465 40 / 8001-phase 12 0.113 EVG-16/1PHAS/12MODUL 291466 40 / 4002-phases 4 0.080 EVG-16/2PHAS/4MODUL 291467 20 / 4002-phases 6 0.120 EVG-16/2PHAS/6MODUL 291468 20 / 4002-phases 12 0.225 EVG-16/2PHAS/12MODUL 291469 20 / 2003-phases 6 0.112 EVG-16/3PHAS/6MODUL 291470 20 / 4003-phases 9 0.163 EVG-16/3PHAS/9MODUL 291471 20 / 2003-phases 12 0.218 EVG-16/3PHAS/12MODUL 291472 20 / 2003-phases 16 0.300 EVG-16/3PHAS/16MODUL 291473 20 / 803-phases 20 0.363 EVG-16/3PHAS/20MODUL 291474 10 / 1004-phases 8 0.200 EVG-16/4PHAS/8MODUL 291475 10 / 1004-phases 12 0.284 EVG-16/4PHAS/12MODUL 291476 10 / 100

1- to 4-phases

16 mm2 - Rated current 80 A

1.133

133 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsEuro-Vario-Busbar (Fork) EVG

Phases MU Cu-factor TypeDesignation

Article No. Units perpackage

4-phases 18 0.260 EVG-16/4PHAS/L-N-X/6PC 116880 104-phases 24 0.360 EVG-16/4PHAS/L-N-X/8PC 116881 10

For 2-pole Combined RCD/MCB Device with a width of 3MU

3-phases 4+5 0.179 EVG-16/3PHAS/N/5MODUL/LS 291477 20 / 2003-phases 4+8 0.244 EVG-16/3PHAS/N/8MODUL/LS 291478 20 / 200

For combination RCD/MCBs with RCD 4-pole

Wa_sg01602

1-phase 2.5 0.038 EVG-16/1PHAS/2MODUL/HI 291479 40 / 8001-phase 8.5 0.105 EVG-16/1PHAS/6MODUL/HI 291480 40 / 4001-phase 13 0.162 EVG-16/1PHAS/9MODUL/HI 291481 40 / 1602-phases 4.5 0.080 EVG-16/2PHAS/4MODUL/HI 291482 20 / 4002-phases 7 0.120 EVG-16/2PHAS/6MODUL/HI 291483 20 / 2002-phases 12 0.200 EVG-16/2PHAS/10MODUL/HI 291484 20 / 2003-phases 6.5 0.130 EVG-16/3PHAS/6MODUL/HI 291485 20 / 2003-phases 13.5 0.260 EVG-16/3PHAS/12MODUL/HI 291486 20 / 803x1-phase 8.5 0.231 EVG-16/3x1PHAS/6MODUL/HI 291487 20 / 2003x1-phase 11.5 0.300 EVG-16/3x1PHAS/8MODUL/HI 291488 20 / 2003x1-phase 13 0.344 EVG-16/3x1PHAS/9MODUL/HI 291489 20 / 80

For applications with Auxiliary Switch

Description Euro-Vario-Busbar (Fork) EVG

• Euro Vario busbars (EVG) offer maximum user comfort and a high degree of safety.• Using EVG busbars helps to save up to 30 % assembly time as compared to conventional systems.• The danger of fl ashover is minimised since there is no need of cutting, burring, or cleaning.• No end caps are needed.

Technical DataEVG

ElectricalRated voltage 240/415 V, 50/60 HzRated current

10 mm2 63 A16 mm2 80 A

Short-circuit current strength 25 kAMechanicalBusbar length 2, 6, 9, 12, 16, 20 MUBusbar cross section 10 and 16 mm2 CuStep distance

10 mm2 17.8 mm / 26.8 mm / 71.2 mm16 mm2 17.8 mm / 27 mm / 71.2 mm

1.134Busbar Systems

Euro-Vario-Busbar (Fork) EVG

134 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description of Euro-Vario-Busbar (Fork) EVG

Devices to busbar Pcs. of the devices Type

1-phase

2-phases

3-phases

4-phases

For 2-pole Combined RCD/MCB Device, 1-phase

For combination RCD/MCBs with RCD 4-pole, 3-phases

1-phase + Auxiliary Switch

2-phases + Auxiliary Switch

3-phases + Auxiliary Switch

For 2-pole Combined RCD/MCB Device, 4-phases

1.135

135 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsVertical Busbar BB-V-16/1P+N

wa_sg02616

1.136Busbar Systems

Vertical Busbar BB-V-16/1P+N

136 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description TypeDesignation

Article No. Units perpackage

Vertical Busbar 16mm2 BB-V-16/1P+Nwa_sg02616 2-phases BB-V-16/1P+N 186887 5

Description Vertical Busbar 16mm2 BB-V-16/1P+N

Attention:The thermal overload protection for the RCCB installing next to the vertical busbar must be considered (please refer to our catalogue register RCCBIn = 16A RCCB => 10 A gG/gL Fuse/Main IncomerIn = 25-40A RCCB => 25 A gG/g Fuse/Main IncomerIn = 63A RCCB => 40 A gG/gL Fuse/Main Incomeror country specifi c wiring regulations).

The thermal emission from the vertical busbar can affect the tripping characteristics of the neighboring RCDs, please follow notes in our product documentation regarding possible temperature derating.Thermal overload protection for the vertical busbar according to EN61439-3 must be considered => nominal current 80A, max. 84A for 15 minutes, maximum setting for ELCB NF: 60A.

Technical DataBB-V-16/1P+N

GeneralBusbar CopperSurface busbar plainInsulation PA66Surface insulation grey RAL 7035Standards EN 60947-1:2007 / IEC 60947-1:2007Temperature resistance 125 °C – UL94 V0CTI Insulation 600 VInsulation coordination Overvoltage category III / Pollution degree 2ElectricalMax. electrical load 690 V ACProtection class IP20Rated peak withstand voltage Uimp 6 kVRated insulation voltage Ui 800 VCapacity at 35 °C ambient temperatureMax. current with bar cross section 16 mm2 Is/Phase 80 A

Products are EU comform and correspond to the RoHS of the EU

Dimensions (mm)

1.137

137 EATON CORPORATION xxxxx+xxxx-xxxxEN

Busbar SystemsAFDD-Busbar EVG-2PHAS/4AFDD

sg05517

1.138Busbar Systems

AFDD-Busbar EVG-2PHAS/4AFDD

138 EATON CORPORATION xxxxx+xxxx-xxxxEN

sg05517

2-phase 0.114 EVG-2PHAS/4AFDD 193378 10

Phases Cu-factor Type Article No. Units perDesignation package

10 mm2

Technical Data

EVG-2PHAS/4AFDDGeneralBusbar CopperSurface busbar plainInsulation PC/ABSSurface insulation greyStandards EN 60947-1:2007 / IEC 60947-1:2007Heat defl ection temperature 90 °C – UL94 V0Glow Wire Flammability Index 960 °C / 1 mmInsulation coordination Overvoltage category III / Pollution degree 2ElectricalMax. operating voltage 690 V AC/DCProtection class IP20Rated impulse withstand voltage Uimp 4,5 kVMax. operating voltage

1-, 3-phase 690 V IEC480Y/277V & 240 V AC

Load Capacity at 35 °C ambient temperature depending of feeding pointMax. busbar current feeding at beginning / ending Is/Phase 50 ABusbar cross section 10 mm2

Connection cross section 10 mm2

Products are EU comform and correspond to the RoHS of the EU

Dimensions (mm)

1.139

139 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse Devices

D0 Fuse-Bases

D0 Switch-Disconnectors

Cylindrical Switch-Disconnectors

D0

D0

C

SG80911

DIN rail

FrameMounting

1.140Fuse Devices

Fuse-Base D01+D02

140 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Fuse-Base D01+D02

Rated current(A)

Poles Width(mm)

TypeDesignation

Article No. Units perpackage

SG80211 63 1 27 FCFBD02DI-1 148599 1563 3 81 FCFBD02DI-3 148810 5

• One design for Fuse-Links size D02 and D01, because adapter springs for screw caps D02 are in scope of delivery• Only screw cap D02 for all applications necessary• Mounting on DIN-rail or mounting plate possible• Finger and hand touch safe according to DGUV VS3, EN 50274• Fuse-Base is equipped with holes for sealing

Description TypeDesignation

Article No. Units perpackage

Fuse-Base FCFBD02DI

Screw Caps Z-D0./SKwa_sg04013 D01 max. 16 A Z-D01/SK 100650 20

D02 max. 63 A Z-D02/SK 100651 20

Adapter Spring Z-D02/SIKA-HF

wa_sg02612 D02-D01 Z-D02/SIKA-HF 263149 50 / 3000

• To apply D01-Fuse-Links into the screw cap Z-D02/SK

Accessories for FCFBD02DI-.

Fuse-Links Z-D0./SE-...Cartridge-ring adapter inserts Z-D02-PE-… and Z-D02-D01-PE-…Adapter Spring Z-D02/SIKA-HF (scope of delivery)Cartridge-ring adapter insert plier Z-D0-PE-Zsee chapter Accessories Fuse Devices.For busbar blocks and feed terminals refer to fuse-switch-disconnector and busbar systems.

Description Fuse-Base FCFBD02DI

• According to DIN VDE 0636-301• For Fuse-Links size D02 and D01• Can be sealed with leads• Silicone-, halogen- and phosphorfree• Cartridge-ring adapter inserts Z-D02-PE and Z-D02-D01-PErequired for current coding• Low-loss stainless steel terminal (anti-magnetic)

1.141

141 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Base D01+D02

D0

Technical DataFCFBD02DI

ElectricalNumber of poles 1P, 3PRated voltage 400 V AC, 250 V DCRated current

D01 16 AD02 63 A

Conditional rated short circuit current tested with inserts Operating class gG (gL)AC 50 kADC 8 kA

Short-circuit current strength 25 kAMechanicalFrame size 45 mmDevice height 68 mmDevice width 27 mm per poleWeight

1P 74 g3P 213 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Screw fastening on mounting plate screw 4 mm, head 7 mm

Upper and lower terminals lift terminalsTerminal capacity 1.5-35 mm2

Tightening torque of terminal screws 3.5 NmFlame class according to UL94 V0Comparative tracking index CTI 600

Dimensions (mm) Operation position

Examples

3-phases 16 mm2

1-phase 35 mm23-phases 35 mm2

Terminal capacity Z-EK/95, Z-EK/95-1:25-95 mm2 single-/fi ne-wire16-70 mm2 fi ne wires with wire end sleeve

1.142Fuse Devices

Switch-Disconnector-Fuse D01

142 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Switch-Disconnector-Fuse D01

Poles Rated constant current(A)

TypeDesignation

Article No. Units perpackage

SG80411 1 max. 16 Z-SLS/D01/1 263155 181+N max. 16 Z-SLS/D01/1+N 263158 92 max. 16 Z-SLS/D01/2 263156 93 max. 16 Z-SLS/D01/3 263157 63+N max. 16 Z-SLS/D01/3+N 263159 4

• Rated operational voltage 230/400 V AC1-pole 60 V DC, 2-pole 110 V DC

• Suitable for fuse-links with operating classes gG (gL), aM• Mechanical current coding is integrated• Can be sealed with leads• Supply side from top or bottom

With visual tripping indicator Z-SLS/D01 (empty)

Accessories

Fuse-Links Z-D01/SE-..see chapter Accessories Fuse Devices

Description Switch-Disconnector-Fuse D01

• Design according to IEC/EN 60947-3• Mechanical current coding by means of integrated, adjustable coding ring• Plug-in technology without screw caps• Visual tripping indicator is fl ashing• Suitable for the following fuse-links

D01: 2, 4, 6, 10, 16 A

Connection diagram1P 1P+N 2P 3P 3P+N

Dimensions (mm)

1.143

143 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesSwitch-Disconnector-Fuse D01

D0

Technical DataZ-SLS/D01

ElectricalNumber of poles 1P, 1P+N, 2P, 3P, 3P+NRated operational voltage Ue

AC 400 VDC 1P to 60 V / 2P to 110 V

Rated operational current Ie 16 ARated constant current Iu 16 AConditional rated short circuit current 50 kAr.m.s.

Utilization category AC 22B, DC 21BOvervoltage category IVRated peak withstand voltage Uimp 6 kVPower loss per current path Ie 0.64 WPower loss per current path with fuse-link Ie 2.24 WMechanicalFrame size 45 mmDevice height 86 mmDevice width 17.5 mm per pole (1MU)Weight

1P 90 g1P+N 170 g2P 180 g3P 270 g3P+N 350 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection IP20Upper and lower terminals lift terminalsTerminal capacity 1.5-25 mm2

Tightening torque of terminal screws max. 2.5 NmTemperature range -25 to +60 °CFlame class V0, glowing wire test 960 °CPollution degree 3Comparative tracking index CTI 600

Examples

oder

1.144Fuse Devices

Fuse-Switch-Disconnector D02+D01

144 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Fuse-Switch-Disconnector D02+D01

Poles Rated constant current(A)

TypeDesignation

Article No. Units perpackage

SG80611 1 max. 63 Z-SLS/NEOZ/1 248235 121+N max. 63 Z-SLS/NEOZ/1+N 248237 62 max. 63 Z-SLS/NEOZ/2 248233 63 max. 63 Z-SLS/NEOZ/3 248234 43+N max. 63 Z-SLS/NEOZ/3+N 248236 33+PEN max. 63 Z-SLS/NEOZ/3+PEN 182399 3

• Rated operational voltage 1-pole 60-230 V AC / 60-110 V DC2-pole 60-400 V AC / 60-220 V DC1+N, 3-pole, 3+N, 3+PEN 60-400 V AC

• Suitable for fuse-links with operating classes gG (gL), aM• Mechanical current coding with Fuse-Link set• Can be sealed with leads• Supply side from top or bottom

Standard Z-SLS/NEOZ (empty)

Accessories

Metal locking device for 1-pole Z-SLZ/SCPlastic locking device for 1-pole Z-SLZ/SPFuse-Link set with visual tripping indicator Z-SLS/B-..Fuse-Link set without visual tripping indicator Z-SLS/E-..Plug-in Busbars ...

Description Fuse-Switch-Disconnector Z-SLS/NEOZ, Standard

• Design according to IEC/EN 60947-3• Mechanical current coding• Plug-in technology without screw caps• Suitable for the following fuse-links

D01: 1, 2, 4, 6, 10, 13, 16 AD02: 20, 25, 32, 35, 40, 50, 63 A

• Can be sealed with leads

Connection diagram1P 1P+N 2P 3P 3P+N 3P+PEN

PEN

PEN

1.145

145 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Technical DataZ-SLS/NEOZ

ElectricalNumber of poles 1P, 1P+N, 2P, 3P, 3P+NRated operational voltage Ue

AC 1P, 1P+N 230 V 2P, 3P, 3P+N 400 VDC 1P bis 110 V 2P bis 220 V

Rated operational current Ie 63 ARated constant current Iu 63 AConditional rated short circuit current 50 kAr.m.s.

Utilization category AC 22B, DC 21BOvervoltage category IVRated peak withstand voltage Uimp 6 kVPower loss per current path Ie

L1, L2, L3 0.5 WN 1 W

Power loss per current path with fuse-link Ie L1, L2, L3 6.6 WMax. permissible power loss of fuse-links 5.5 WMechanicalFrame size 45 mmDevice height 86 mmDevice width 27 mm per pole (1.5MU)Weight

1P 113 g1P+N 225 g2P 224 g3P 450 g3P+N 472 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection (behind front plate) IP20CUpper and lower terminals lift terminalsTerminal capacity 1.5-35 mm2

Tightening torque of terminal screws max. 4 NmTemperature range

Ambient air -25 to +40 °C, on 24h average +35 °CStorage -25 to +60 °C

Temperature rise limitsTerminals +70 °KManual operating means +25 °KParts intended to be touched +40 °KParts need not to be touched +50 °K

Flame class V0, glowing wire test 960 °CPollution degree 3Comparative tracking index CTI 600

Dimensions (mm)

1.146Fuse Devices

Fuse-Switch-Disconnector D02+D01

146 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Examples

Terminal capacity Terminal capacity

Terminal capacity

Terminal capacity

1.147

147 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Fuse-Switch-Disconnector D02+D01

Poles Rated constant current(A)

TypeDesignation

Article No. Units perpackage

SG80711 1pole 10 Z-SLS/CEK10/1 272587 121pole 16 Z-SLS/CEK16/1 263135 121pole 25 Z-SLS/CEK25/1 263136 123pole 16 Z-SLS/CEK16/3 248243 43pole 25 Z-SLS/CEK25/3 248244 43pole 35 Z-SLS/CEK35/3 248245 43pole 40 Z-SLS/CEK40/3 150687 43pole 50 Z-SLS/CEK50/3 248246 43pole 63 Z-SLS/CEK63/3 263160 4

• Rated operational voltage 1-pole 60-230 V AC / 60-110 V DC3-pole 60-400 V AC

• Fuse carrier with visual tripping indicator and fuses inclusive• Mechanical current coding with Fuse-Link set• Can be sealed with leads• Supply side from top or bottom

Complete with captive current code Z-SLS/CEK

Accessories

Metal locking device for 1-pole Z-SLZ/SCPlastic locking device for 1-pole Z-SLZ/SPFuse-Link set with visual tripping indicator Z-SLS/B-..Fuse-Link set without visual tripping indicator Z-SLS/E-..Plug-in Busbars ...

Description Fuse-Switch-Disconnector Z-SLS/CEK, complete with captive current code

• Design according to IEC/EN 60947-3• Can be used as main fuse downstream of the meter according to the Technical Connection Rules of the Austrian Power Supply Companies („TAEV“)• Current coding by the manufacturer• Plug-in technology without screw caps• Suitable for the following fuse-links

D01: 10, 16 AD02: 25, 35, 40, 50, 63 A

• Can be sealed with leads• Visual tripping indicator included

Connection diagram1P 3P

1.148Fuse Devices

Fuse-Switch-Disconnector D02+D01

148 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Technical DataZ-SLS/CEK

ElectricalNumber of poles 1P, 3PRated operational voltage Ue

1P 230 V AC3P 400 V AC

Rated constant current Iu1P 10, 16, 25 A3P 16, 25, 35, 40, 50, 63 A

Conditional rated short circuit current 50 kAr.m.s.

Utilization category AC 22BOvervoltage category IVRated peak withstand voltage Uimp 6 kVPower loss per current path at 63A L1, L2, L3 0.5 WPower loss per current path

with fuse-link L1, L2, L310 A 2.0 W16 A 2.5 W25 A 3.7 W35 A 4.3 W40 A 5.2 W50 A 5.7 W63 A 6.6 W

Max. permissible power loss of fuse-links 5.5 WMechanicalFrame size 45 mmDevice height 86 mmDevice width 27mm per pole (1.5MU)Weight

1P 147 g3P 441 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection (behind front plate) IP20CUpper and lower terminals lift terminalsTerminal capacity 1.5-35 mm2

Tightening torque of terminal screws max. 4 NmTemperature range

Ambient air -25 to +40 °C, on 24h average +35 °CStorage -25 to +60 °C

Temperature rise limitsTerminals +70 °KManual operating means +25 °KParts intended to be touched +40 °KParts need not to be touched +50 °K

Flame class V0, glowing wire test 960 °CPollution degree 3Comparative tracking index CTI 600

Dimensions (mm)

1.149

149 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Example

Terminal capacity

1.150Fuse Devices

Fuse-Switch-Disconnector D02+D01

150 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Fuse-Switch-Disconnector D02+D01

Poles Rated constant current(A)

TypeDesignation

Article No. Units perpackage

SG80911 1+HS max. 63 Z-SLK/NEOZ/1 248238 62+HS max. 63 Z-SLK/NEOZ/2 248239 43+HS max. 63 Z-SLK/NEOZ/3 248240 33+N+HS max. 63 Z-SLK/NEOZ/3+N 248241 2

• Rated operational voltage 1-pole 60-230 V AC / 60-110 V DC2-pole 60-400 V AC / 60-220 V DC1+N, 3-pole, 3+N 60-400 V AC

• Mechanical current coding with Fuse-Link set• Can be sealed with leads• Supply side from top or bottom

With fuse monitoring Z-SLK/NEOZ (empty)

Accessories

Metal locking device for 1-pole Z-SLZ/SCPlastic locking device for 1-pole Z-SLZ/SPFuse-Link set with visual tripping indicator Z-SLS/B-..Fuse-Link set without visual tripping indicator Z-SLS/E-..Plug-in Busbars ...

Description Fuse-Switch-Disconnector Z-SLK/NEOZ, with fuse monitoring

• Design according to IEC/EN 60947-3• Fuse monitoring by relay contact• Mechanical current coding• Plug-in technology without screw caps• Suitable for the following fuse-links

D01: 1, 2, 4, 6, 10, 13, 16 AD02: 20, 25, 32, 35, 40, 50, 63 A

• Can be sealed with leads• Other AC/DC voltages requires special types

Connection diagram1P 2P 3P 3P+N

1.151

151 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Technical DataZ-SLK/NEOZ

ElectricalNumber of poles 1P, 1P+N, 2P, 3P, 3P+NRated operational voltage Ue

AC 1P, 1P+N 60-230 V 2P, 3P, 3P+N 60-400 VDC 1P 60-110 V 2P 60-220 V

Rated operational current Ie 63 ARated constant current Iu 63 AConditional rated short circuit current 50 kAr.m.s.Utilization category AC 22B, DC 21BOvervoltage category IVRated peak withstand voltage Uimp 6 kVPower loss per current path Ie

L1, L2, L3 0.5 WN 1 W

Power loss per current path with fuse-link Ie L1, L2, L3 6.6 WMax. permissible power loss of fuse-links 5.5 WAuxiliary Switch 1 NO 5 A / 250 V ACRelay Component electrical componentsRated operational voltage range 24-250 V AC/DCRated operational voltage tolerance ±10%Power consumption 1 VAFrequency 16.67; 50-60 HzFunction display

Line voltage 1 LED greenTrouble 1 LED red

Duty 100%Responding delay approx. 100 ms - 1sReset time 1 sRelay contacts 2 CO, 5 A / 250 V ACAuxiliary switch rated impulse withstand voltage 4 kVOvervoltage category IIIMechanicalFrame size 45 mmDevice height 86 mmDevice width 27 mm/pole (1.5MU) + 27 mmWeight

1P 224 g2P 345 g3P 450 g3P+N 590 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection (behind front plate) IP20CUpper and lower terminals lift terminalsTerminal capacity 1.5-35 mm2

Tightening torque of terminal screws max. 4 NmTemperature range

Ambient air -25 to +40 °C, on 24h average +35 °CStorage -25 to +60 °C

Temperature rise limitsTerminals +70 °KManual operating means +25 °KParts intended to be touched +40 °KParts need not to be touched +50 °K

Flame class V0, glowing wire test 960 °CPollution degree 3Comparative tracking index CTI 600Relay Component mechanical componentsUpper and lower terminals lift terminalsTerminal capacity

solid 0.14-4 mm2

fi ne-wire 0.14-2.5 mm2

Tightening torque of terminal screws 0.5-0.7 Nm

1.152Fuse Devices

Fuse-Switch-Disconnector D02+D01

152 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Dimensions (mm)

Simplifi ed diagram

13

14

21

A1

24 - 250 V AC/DC

ResetU

A2

3124 3422 32

Z-SLK

1 ... 63 A

Function - Switch position Relay - Fuse monitoring

Uv

24 21 22

34 31 32

24 21 22

34 31 32

Uv

Uv

UvUv

24 21 22

34 31 32

Uv . . . Supply voltage relay

1.153

153 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Fuse-Link sets complete Z-SLS/B, Z-SLS/E

Rated current(A)

TypeDesignation

Article No. Units perpackage

SG81211 1 Z-SLS/B-1A 268983 1 / 122 Z-SLS/B-2A 268984 1 / 124 Z-SLS/B-4A 268985 1 / 126 Z-SLS/B-6A 268986 1 / 1210 Z-SLS/B-10A 268987 1 / 1213 Z-SLS/B-13A 289972 1 / 1216 Z-SLS/B-16A 268988 1 / 1220 Z-SLS/B-20A 268989 1 / 1225 Z-SLS/B-25A 268990 1 / 1232 Z-SLS/B-32A 289973 1 / 1235 Z-SLS/B-35A 268991 1 / 1240 Z-SLS/B-40A 289974 1 / 1250 Z-SLS/B-50A 268992 1 / 1263 Z-SLS/B-63A 268993 1 / 12

• Rated operational voltage 60-400 V AC

With visual tripping indicator Z-SLS/B

• For Z-SLS/NEOZ, Z-SLS/CEK, Z-SLK/NEOZ• 1 set consists of 3 fuse-links, 3 gauge-pieces, 1 plastic box in the color of the visual tripping indicator

- to snap on DIN rail

1 Z-SLS/B/24-1A 268994 1 / 122 Z-SLS/B/24-2A 268995 1 / 124 Z-SLS/B/24-4A 268996 1 / 126 Z-SLS/B/24-6A 268997 1 / 1210 Z-SLS/B/24-10A 268998 1 / 1213 Z-SLS/B/24-13A 289975 1 / 1216 Z-SLS/B/24-16A 268999 1 / 1220 Z-SLS/B/24-20A 269000 1 / 1225 Z-SLS/B/24-25A 269001 1 / 1232 Z-SLS/B/24-32A 289976 1 / 1235 Z-SLS/B/24-35A 269002 1 / 1240 Z-SLS/B/24-40A 289977 1 / 1250 Z-SLS/B/24-50A 269003 1 / 1263 Z-SLS/B/24-63A 269004 1 / 12

• Rated operational voltage 24-60 V AC / V DC

With visual tripping indicator Z-SLS/B

2 Z-SLS/E-2A 263147 1 / 124 Z-SLS/E-4A 263148 1 / 126 Z-SLS/E-6A 269005 1 / 1210 Z-SLS/E-10A 269006 1 / 1213 Z-SLS/E-13A 289978 1 / 1216 Z-SLS/E-16A 269007 1 / 1220 Z-SLS/E-20A 269008 1 / 1225 Z-SLS/E-25A 269009 1 / 1232 Z-SLS/E-32A 289979 1 / 1235 Z-SLS/E-35A 269010 1 / 1240 Z-SLS/E-40A 289990 1 / 1250 Z-SLS/E-50A 269011 1 / 1263 Z-SLS/E-63A 269012 1 / 12

• Rated operational voltage 400 V AC, 220 V DC

Without visual tripping indicatorZ-SLS/E

1.154Fuse Devices

Fuse-Switch-Disconnector D02+D01

154 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Description Fuse-Link sets complete Z-SLS/B, Z-SLS/E

• Fuse-Links with fl ashing function (Z-SLS/B) in case of disconnection• Fuse-Links without fl ashing function (Z-SLS/E) upon enquiry, not on stock• Supplied as a set with 3 fuse-links and 3 gauge-pieces in plastic box of different colours which can be mounted onto DIN rail.• Dimensions of plastic box:

Frame size 45 mmDepth 75 mmWidth 54 mm

Connection diagram

Technical DataZ-SLS/B, Z-SLS/E

ElectricalOperating class gG (gL)Rated voltage

Z-SLS/B/24 24 - 60 V AC, 24 - 60 V DCZ-SLS/B 60 - 400 V ACZ-SLS/E 400 V AC, 220 V DC

Test voltage 5 kVMechanicalSize

D01 1, 2, 4, 6, 10, 13, 16 AD02 20, 25, 32, 35, 40, 50, 63 A

Characteristics

Time/current characteristics of D0-Fuse-Links 2 ... 63A gG(gL) Let-through characteristics of D0-Fuse-Links 2 ... 63A gG(gL)

310

210

110

010

-110

-210

-310

2 41

10 2 42

10 2 43

10 2 44

10

Schm

elz

ze

ittin

s

Unbeeinflusster Strom I in AP

Nennstrom I in AN2 4 6 10 16 20 25 35 50 63

2I 2P I 2P

20

10

4

2

1

0,4

0,2

0,1

0,1 0,2 0,4 1 2 4 10 20 100

Kurzschlussstrom I in kAP

Ne

nn

str

om

Iin

AN

2

4

6

10

16

20

25

35

50

63

Du

rch

lassstr

om

Iin

kA

D

ß

Mtgrö

tem

Gle

ihst

rom

glie

d

i

c

One

Gle

ichst

rom

glie

d

h

Möglic

he

Sto

ßku

rzsc

hlu

ssst

röm

e

Prospective current IP in A

Vir

tual

pre

-arc

ing

time

t in

s

Let-

thro

ugh

curr

ent I

D in

kA

Prospective short-circuit current IP in kA

Rat

ed c

urre

nt I N

in APo

ssibl

e sho

rt-cir

cut p

eak c

urre

nts

With la

rgest

direc

t curr

ent c

ompo

nent

Withou

t dire

ct curr

ent co

mponen

t

1.155

155 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Solid-link Set complete Z-SLS/TR-SET

Rated current(A)

TypeDesignation

Article No. Units perpackage

SG81311 63 Z-SLS/TR-SET 100660 1 / 12

• For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK• 1 set consists of 3 solid-link inserts, 3 gauge-pieces, 1 plastic box to be snapped onto DIN rail• By installing this set, the fuse-switch-disconnector is converted into a switch-disconnector

Description Solid-link Set complete Z-SLS/TR-SET

• Supplied as a set with 3 solid-links inserts and 3 gauge-pieces in plastic box which can be mounted onto DIN rail.• Dimensions of plastic box:

Frame size 45 mmDepth 75 mmWidth 54 mm

Connection diagram

Technical DataZ-SLS/TR-SET

ElectricalRated voltage 400 V ACRated constant current Iu 63 ATest voltage 5 kVMechanicalSize D02 63 A

1.156Fuse Devices

Fuse-Switch-Disconnector D02+D01

156 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Switch-on-locking Z-SLZ/SP

Description TypeDesignation

Article No. Units perpackage

SG81011 Plastic lock Z-SLZ/SP 268981 1 / 12

• For Z-SLS/NEOZ, Z-SLS/CEK, Z-SLK/NEOZ•Only one lock per device required

1.157

157 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Fuse-Switch-Disconnector D02+D01

Poles Rated constant current(A)

TypeDesignation

Article No. Units perpackage

SG80811 1 max. 63 Z-SLS/CB/1 248247 121+N max. 63 Z-SLS/CB/1+N 167282 62 max. 63 Z-SLS/CB/2 248248 63 max. 63 Z-SLS/CB/3 248249 43+N max. 63 Z-SLS/CB/3+N 167283 3

With visual tripping indicator Z-SLS/CB - Current coding by cartridge-ring adapter inserts

Accessories

Fuse-Links Z-D0./SE-..Cartridge-ring adapter inserts D01 Z-D02-D01/PE-..Cartridge-ring adapter inserts D02 Z-D02/PE-..Adapter Spring D01 Z-SLS/CB-HF see chapter Accessories Fuse Devices

Description Fuse-Switch-Disconnector with visual tripping indicator Z-SLS/CB - Current coding by cartridge-ring adapter inserts

• Design according to IEC/EN 60947-3• Current coding by means of cartridge-ring adapter inserts• Visual tripping indicator is fl ashing• Suitable for the following fuse-links

D01: 2, 4, 6, 10, 13, 16 A with cartridge-ring adapter insert Z-D02-D01/PE-.. and Adapter Spring Z-SLS/CB-HF D02: 20, 25, 32, 35, 40, 50, 63 A• Can be sealed with leads

Connection diagram

Dimensions (mm)

Poles Dimension a [mm]1P 271+N 542P 543P 813+N 108

1.158Fuse Devices

Fuse-Switch-Disconnector D02+D01

158 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Technical DataZ-SLS/CB

ElectricalNumber of poles 1P, 1+N, 2P, 3P, 3+NRated operational voltage Ue

1P, 1P+N 230 V AC2P, 3P, 3P+N 400 V AC

Rated operational current Ie 63 ARated constant current Iu 63 AConditional rated short circuit current 50 kAr.m.s.

Utilization category AC 22BOvervoltage category IVRated peak withstand voltage Uimp 6 kVPower loss per current path Ie 0.5 WPower loss per current path with fuse-link Ie 7.5 WMechanicalFrame size 45 mmDevice height 86 mmDevice width 27 mm per pole (1.5MU)Weight

1P 120 g1P+N 230 g2P 230 g3P 350 g3P+N 448 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection IP20Upper and lower terminals lift terminalsTerminal capacity 1.5-35 mm2

Tightening torque of terminal screws max. 4 NmTemperature range -25 to +60 °CFlame class V0, glowing wire test 960 °CPollution degree 3Comparative tracking index CTI 600

Examples

Terminal capacityTerminal capacity

Terminal capacity

1.159

159 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector D02+D01

D0

Adapter Spring Z-SLS/CB-HF

Size TypeDesignation

Article No. Units perpackage

wa_sg02712 D01 Z-SLS/CB-HF 263154 12 / 288

• For Z-SLS/CB/. for the use of fuse-links size D01

Double Terminal Z-SLZ/KL

Description TypeDesignation

Article No. Units perpackage

SG60212 Terminal 2 x 3x35 mm2 Z-SLZ/KL 268982 15

• For Z-SLS/NEOZ, Z-SLS/CEK, Z-SLK/NEOZ

Accessories for Z-SLS

For busbar blocks and feed terminals refer to the technical part, fuse-switch-disconnector, and ordering part, busbar systems.

Terminal capacity

1.160Fuse Devices

Switch-Disconnector-Fuse D02+D01

160 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0 C

Switch-Disconnector-Fuse D02+D01

Poles Rated constant current(A)

TypeDesignation

Article No. Units perpackage

SG80711 3 max. 63 D02-LTS/63-3 114320 33 max. 63 D02-LTS/63-3-HK 114322 33N max. 63 D02-LTS/63-3N 114321 3

With visual tripping indicator D02-LTS

Accessories for D02-LTS

D0 Fuse-Links Z-D0./SE-...Cartridge-ring adapter inserts D01: Z-D02-D01/PE-...

D02: Z-D02/PE-...Adapter Spring Z-D02-LTS-HF (scope of delivery)

C Fuse-Links Z-C10/SE-...Adapter Spring Z-D02-LTS-HF (scope of delivery)

Siehe Fuse Devices Accessories

Description Switch-Disconnector-Fuse D02-LTS - Current coding by cartridge-ring adapter inserts

• Design according to IEC/EN 60947-3• Current coding by means of cartridge-ring adapter inserts• Visual tripping indicator is fl ashing• Suitable for fuse-links with operating classes gG (gL), aM

D01: 2, 4, 6, 10, 13, 16 A with cartridge-ring adapter insert Z-D02-D01/PE-.. and Adapter Spring Z-D02-LTS-HF D02: 20, 25, 32, 35, 50, 63 A Cylindrical 10x38 up to 32 A with adapter spring Z-D02-LTS-HF• Can be sealed with leads

• Rated operational voltage 400 V AC• Suitable for fuse-links with operating classes gG (gL), aM• Only 4MU in width, busbar compatible to Xpole switchgear• Current coding by cartridge-ring adapter inserts• Can be sealed with leads• Supply side from top or bottom• Version with Auxiliary Switch D02-LTS/63-3-HK• Delivered with Adapter Springs for fuse-links D01 or cylindrical fuse-links 10x38

SG81811 16 32

D02-D01C 10x38

Z-D02-LTS-HF 114323 12 / 288

Adapter Spring Z-D02-LTS-HF• To accomodate D01 fuse-links or cylindrical fuse-links 10x38 in the Switch-disconnetorfuse D02-LTS/63...

Max. Rated operational current Ie (A)

Size TypeDesignation

Article No. Units perpackage

Connection diagram

14

13

6

5

4

3

2

1

3P 3P+N 3P+HK8

7

6

5

4

3

2

1

6

5

4

3

2

1

1.161

161 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesSwitch-Disconnector-Fuse D02+D01

D0 C

Technical DataD02-LTS

ElectricalNumber of poles 3P, 3P+N, 3P+HKRated operational voltage Ue 400 V ACRated operational voltage range 48-400 V ACRated operational current Ie 63 ARated constant current Iu 63 AConditional rated short circuit current 50 kAr.m.s.

Utilization category AC 22BOvervoltage category IVRated peak withstand voltage Uimp 6 kVPower loss per current path Ie 1.8 WPower loss per current path with fuse-link Ie 7.3 WMax. permissible power loss of fuse-links 5.5 WAuxiliary Switch

1P 1 NO 5 A / 250 V ACMax. thermal back-up protection 2 A gL

MechanicalFrame size 45 mmDevice height 86 mmDevice width 18 mm per pole (1MU)Weight

3P 340 g3P+N 380 g3P+HK 380 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection IP20Upper and lower terminals lift terminalsTerminal capacity 1.5-25 mm2

Tightening torque of terminal screws max. 3 NmTemperature range -25 to +60 °CFlame class V0, glowing wire test 960 °CPollution degree 3Comparative tracking index CTI 600

Dimensions (mm)N

N

Example 3P, 3P+N

4015082914752

N

N

EVG-16/4PHAS/8MODUL

1.162Fuse Devices

Fuse-Disconnector (empty)

162 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse-Disconnector (empty)

Poles Size TypeDesignation

Article No. Units perpackage

SG81211

1 10x38 Z-SH/1 263876 12 / 1201+N 10x38 Z-SH/1N 263877 12 / 1202 10x38 Z-SH/2 263878 6 / 603 10x38 Z-SH/3 263879 4 / 403+N 10x38 Z-SH/3N 263880 4 / 40

For industry Z-SH

• For cylindrical fuse-links• The visual tripping indicator indicates the tripped fuse-link• Can be sealed with leads

C

Without visual tripping indicator

SG36412

1 10x38 Z-SHL/1 263883 12 / 1201+N 10x38 Z-SHL/1N 263884 12 / 1202 10x38 Z-SHL/2 263885 6 / 603 10x38 Z-SHL/3 263886 4 / 403+N 10x38 Z-SHL/3N 263887 4 / 40

With visual tripping indicator

Rated current(A)

Size TypeDesignation

Article No. Units perpackage

SG00412

10 8.5x23 Z-SI/10/1 263889 12 / 12016 10.3x25.8 Z-SI/16/1 263890 12 / 12020 8.5x31.5 Z-SI/20/1 263891 12 / 12025 10.3x31.5 Z-SI/25/1 263892 12 / 12032 10.3x38 Z-SI/32/1 263893 12 / 120

For household applications Z-SI, 1pole

Without visual tripping indicator

20 8.5x31.5 Z-SIL/20/1 263901 12 / 12025 10.3x31.5 Z-SIL/25/1 263902 12 / 12032 10.3x38 Z-SIL/32/1 263903 12 / 120

With visual tripping indicator

SG53912

10 8.5x23 Z-SI/10/1N 263894 12 / 12016 10.3x25.8 Z-SI/16/1N 263895 12 / 12020 8.5x31.5 Z-SI/20/1N 263896 12 / 12025 10.3x31.5 Z-SI/25/1N 263897 12 / 12032 10.3x38 Z-SI/32/1N 263898 12 / 120

For household applications Z-SI, 1+Npole

Without visual tripping indicator

20 8.5x31.5 Z-SIL/20/1N 263938 12 / 12025 10.3x31.5 Z-SIL/25/1N 263939 12 / 12032 10.3x38 Z-SIL/32/1N 263940 12 / 120

With visual tripping indicator

Accessories for Z-SH, Z-SI

Fuse-Links Z-C/SE...see chapter Accessories Fuse Devices

1.163

163 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Disconnector (empty)

C

Description Fuse-Disconnector for Industrial Applications Z-SH

• Design according to IEC/EN 60947-3• Design

without visual tripping indicator Z-SHwith visual tripping indicator Z-SHL

• Can be sealed with leads• Supplied without fuse-links

Technical DataZ-SH

ElectricalNumber of poles 1P, 1P+N, 2P, 3P, 3P+NRated voltage

1P, 1P+N 230 V AC2P, 3P, 3P+N 400 V AC

Rated operational current Ie 32 AConditional short-circuit current 10 kAr.m.s.

Utilization category AC 20BOvervoltage category IVRated peak withstand voltage Uimp 4 kVFuse-Links 10, 16, 20, 25, 32 A

Operating class gG(gL) / aMMax. Power loss per current path 3.2 W

MechanicalFrame size 45 mmDevice height 80 mmDevice width according to dimensioned drawingWeight Z-SH Z-SHL

1P 74 g 76 g1P+N 84 g 86 g2P 156 g 158 g3P 234 g 236 g3P+N 244 g 246 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection (built-in) IP20 (IP40)Upper and lower terminals lift terminalsTerminal capacity 1.5-10 mm2

Tightening torque of terminal screws max. 2 NmTemperature range -25 to +60 °CDimensions of fuse-link 10.3 x 38 mm

Connection diagramZ-SH/3N

Dimensions (mm)

1.164Fuse Devices

Fuse-Disconnector (empty)

164 EATON CORPORATION xxxxx+xxxx-xxxxEN

C

Visual Tripping Indicator Attention

Do not switch the fuse-disconnector under load

OFF

top

1.165

165 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Disconnector (empty)

C

Description Fuse-Disconnector for Household Applications Z-SI

• Design according to IEC/EN 60947-3• Design

without visual tripping indicator Z-SIwith visual tripping indicator Z-SIL

• Can be sealed with leads• The open fuse drawer can be secured against re-switch-on by means of a padlock• Supplied without fuse-links

Technical DataZ-SI

ElectricalNumber of poles 1P, 1P+NRated voltage 230 V ACRated operational current Ie 32 AConditional short-circuit current 10 kAr.m.s.

Utilization category AC 20BRated peak withstand voltage Uimp 4 kVFuse-Links 10, 16, 20, 25, 32 A

Operating class gG(gL) / aMMax. Power loss per current path 3.2 W

MechanicalFrame size 45 mmDevice height 80 mmDevice width 17.5 mmWeight Z-SI Z-SIL

1P 74 g 76 g1P+N 84 g 86 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection (built-in) IP20 (IP40)Upper and lower terminals lift terminalsTerminal capacity 1.5-10 mm2

Tightening torque of terminal screws max. 2 NmDimensions of fuse-link

Rated current (A) mm10 8.5 x 2316 10.3 x 25.820 8.5 x 31.525 10.3 x 31.532 10.3 x 38

Connection diagram

Dimensions (mm)

1.166Fuse Devices

Fuse-Disconnector (empty)

166 EATON CORPORATION xxxxx+xxxx-xxxxEN

C

Visual Tripping Indicator Attention

Do not switch the fuse-disconnector under load

OFF

top

1.167

167 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector (empty) C10-SLS, VLCE

C

Fuse-Switch-Disconnector (empty) C10-SLS, VLCE

Poles Size TypeDesignation

Article No. Units perpackage

SG27212

1 10x38 C10-SLS/32/1 112220 12 / 1081+N 10x38 C10-SLS/32/1N 112221 12 / 1082 10x38 C10-SLS/32/2 112222 6 / 543 10x38 C10-SLS/32/3 112223 4 / 363+N 10x38 C10-SLS/32/3N 112224 4 / 36

Size 10x38, Rated operational current 32 A, C10-SLS

• The visual tripping indicator indicates the tripped fuse-link• Rated operational voltage 690 V AC• For cylindrical fuse-links with operating classes gG (gL), aM• Can be sealed with leads• Supply side from top or bottom

Without Visual Tripping Indicator

1 10x38 C10-SLS/32/1-L 1 112225 12 / 1081+N 10x38 C10-SLS/32/1N-L 112226 12 / 1082 10x38 C10-SLS/32/2-L 112227 6 / 543 10x38 C10-SLS/32/3-L 112228 4 / 363+N 10x38 C10-SLS/32/3N-L 112229 4 / 36

With Visual Tripping Indicator

wa_sg01917

1 14x51 VLCE14-1P 192373 12 / 961+N 14x51 VLCE14-1P+N 192375 6 / 482 14x51 VLCE14-2P 192376 6 / 483 14x51 VLCE14-3P 192377 4 / 323+N 14x51 VLCE14-3P+N 192379 3 / 24

Size 14x51, Rated operational current 50 A, VLCE14

Without Visual Tripping Indicator

1 14x51 VLCE14-1P/L 192374 12 / 963 14x51 VLCE14-3P/L 192378 4 / 32

With Visual Tripping Indicator

wa_sg02017

1 22x58 VLCE22-1P 192380 3 / 1051+N 22x58 VLCE22-1P+N 192381 2 / 482 22x58 VLCE22-2P 192382 2 / 483 22x58 VLCE22-3P 192370 1 / 353+N 22x58 VLCE22-3P+N 192372 1 / 24

Size 22x58, Rated operational current 100 A, VLCE22

Without Visual Tripping Indicator

3 22x58 VLCE22-3P/L 192371 1 / 35

With Visual Tripping Indicator

Accessories

Fuse-Links Z-C10/SE...Z-C14/SE..Z-C22/SE...

see chapter Accessories Fuse Devices

1.168Fuse Devices

Fuse-Switch-Disconnector (empty) C10-SLS, VLCE

168 EATON CORPORATION xxxxx+xxxx-xxxxEN

C

Description Fuse-Switch-Disconnector C10-SLS, VLCE

• Design according to IEC/EN 60947-3• Design /L with visual tripping indicator (fl ashing)• Suitable for cylindrical fuse-links with operating classes gG, aM

10x38 C10-SLS14x51 VLCE1422x58 VLCE22

• Can be sealed with leads• Supplied without fuse-links

Technical DataC10-SLS VLCE14 VLCE22

ElectricalNumber of poles 1P, 1P+N, 2P, 3P, 3P+N 1P, 1P+N, 2P, 3P, 3P+N 1P, 1P+N, 2P, 3P, 3P+NRated operational voltage Ue

1P 690 V, 50 Hz 690 V, 50 Hz 690 V, 50 Hz1P+N 400 V, 50 Hz 690 V, 50 Hz 690 V, 50 Hz2P, 3P, 3P+N 690 V, 50 Hz 690 V, 50 Hz 690 V, 50 Hz

Rated operational current Ie 32 A 50 A 100 AConditional rated short circuit current 100 kA (at 400 V) 120 kA 120 kARated short-time withstand current Icw 300 A 600 A 1200 AUtilization category Ui AC 22B AC 22B AC 21BRated insulation voltage 690 V 690 V 690 VOvervoltage category II III IIIRated impulse withstand voltage Uimp 4 kV 8 kV 8 kVPower loss per current path without fuse-link 0.9 W 1 W 3.1 WMaximum permissible power loss of fuse-links

gG 3 W 5 W 9.5 WaM 1.2 W 3 W 7 W

MechanicalFrame size 45 mm 45 mm 45 mmDevice height 83.3 mm 94 mm 121 mmDevice width 17.5 mm / pole W = 27 mm / pole W = 36 mm / poleWeight

1P 58 g 100 g 156 g1P+N 70 g 222 g 351 g2P 120 g 206 g 317 g3P 180 g 310 g 476 g3P+N 195 g 434 g 671 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection IP20 IP20 IP20Upper and lower terminals lift terminals lift terminals lift terminalsTerminal capacity 0.5 - 10 mm2 1.5 - 35 mm2 4 - 50 mm2

AWG 20-8 AWG 18-6 AWG 12-2Tightening torque of terminal screws 1.2 Nm 2.5 - 3 Nm 2.5 - 3 NmAmbient temperature range -25 to +40 °C -25 to +40 °C -25 to +40 °CFlame class glow wire 960 °C glow wire 960 °C glow wire 960 °CPollution degree 2 3 3Comparative tracking index CTI 450 CTI 450 CTI 450

Connection diagram1P 1P+N 2P 3P 3P+N

1.169

169 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Switch-Disconnector (empty) C10-SLS, VLCE

C

Dimensions (mm)C10-SLS VLCE14 VLCE22

1.170Fuse Devices Photovoltaic

Fuse-Disconnector (empty) FCFDC10DI-..-SOL

170 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse-Disconnector (empty) FCFDC10DI-..-SOL

Poles Size TypeDesignation

Article No. Units perpackage

wa_sg00210

1 10x38 FCFDC10DI-1-SOL CHPV1U 12/1082 10x38 FCFDC10DI-2-SOL CHPV2U 6/54

Size 10x38 FCFDC10DI, Rated operational current 25 A DC

• String protection of PV generator• The visual tripping indicator indicates the tripped fuse-link

50-400 V fl ashing400-1000 V permanent light

• Rated operational voltage 1000 VDC• For cylindrical fuse-links photovoltaic application• Lead-sealable

Without Visual Tripping Indicator

1 10x38 FCFDC10DI-1L-SOL CHPV1IU 12/1082 10x38 FCFDC10DI-2L-SOL CHPV2IU 6/54

With Visual Tripping Indicator

CDC

Applikation PhotovoltaicEarthed System

Unearthed System

FCFDC10DI-1-SOL FCFDC10DI-1L-SOL

FCFDC10DI-1-SOL FCFDC10DI-2L-SOL

1.171

171 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse Devices PhotovoltaicFuse-Disconnector (empty) FCFDC10DI-..-SOL

CDC

Description Fuse-Disconnector (empty) FCFDC10DI-..-SOL

• Design according to IEC 60947-1 Ed. 4.0, EN 60947-1:1999+A1:2000+A2:2001IEC 60947-3 Ed. 2.1, EN 60947-3:1999+A1:2001

• Design L with visual tripping indicator (fl ashing)• table for cylindrical fuse-links photovoltaic application 10x38 accoording to IEC 60269, UL284-4• Can be sealed with leads• Supplied without fuse-links

Technical DataFCFDC10DI-..-SOL

ElectricalNumber of poles 1P, 2PRated voltage Ue 1000 V DCRated current Ie 25 AConditional rated short circuit current 10 kAUtilization category DC 20BOvervoltage category IIIRated peak withstand voltage Uimp 6 kVPower loss per current path without fuse-link 0.9 WMaximum permissible power loss of fuse-links 3 WMechanicalFrame size 45 mmDevice height 83.3 mmDevice width 17.5 mm / poleWeight

1P 58 g2P 70 g

Mounting Quick fastening on DIN rail according to IEC/EN 60715Degree of protection IP20Upper and lower terminals lift terminalsTerminal capacity 1.5-10 mm2

AWG 20-8Tightening torque of terminal screws 1.5 NmAmbient temperature range -25 to +40 °CFlame class glow wire 960 °CPollution degree 2Comparative tracking index CTI 450

Connection diagram

1P 2P 1P 2P

FCFDC10DI-.-SOL FCFDC10DI-.L-SOL

1.172Fuse Devices Photovoltaic

Fuse-Disconnector (empty) FCFDC10DI-..-SOL

172 EATON CORPORATION xxxxx+xxxx-xxxxEN

CDC

Connection diagram

- Strings+ Strings

Input

1 3 5

2 4 6

- Strings+ Strings

Output (M20)

Input

+ -

1

+ -

3 5

2 4 6

- Strings+ Strings

Output

Input

+ -

1 3 5

2 4 6

- Strings+ Strings

Output (M16)

Input (M12)

+ -

1 3 5

2 4 6

SOL20/2MC3SOL20/2MC4SOL30/2MC3SOL30/2MC4

SOL20/2MVSOL30/2MV

SOL20/4MC3SOL20/4MC4SOL30/4MC3SOL30/4MC4

- Strings + Strings

Input (M12)

Output (M20)+ -

+ -

1 3 5

2 4 6

- Strings+ Strings

Input

Output (M20)+ -

+ -

1 3 5

2 4 6

SOL60/4MV SOL60/8MC3SOL60/8MC4

SOL60/4MC3SOL60/4MC4

Dimensions (mm)

17.5

1.173

173 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Links Z-D0./SE, Operating class gG (gL)

D0

Fuse-Links Z-D0./SE, Operating class gG (gL)

Size Rated current(A)

TypeDesignation

Article No. Units perpackage

SG81111 D01 2 Z-D01/SE-2 288934 12/288D01 4 Z-D01/SE-4 288935 12/288D01 6 Z-D01/SE-6 288936 12/288D01 10 Z-D01/SE-10 288937 12/288D01 13 Z-D01/SE-13 288938 12/288D01 16 Z-D01/SE-16 288939 12/288

• In practical plastic box in the color of the visual tripping indicator - to snap on DIN rail

SG81911 D02 20 Z-D02/SE-20 288940 12/144D02 25 Z-D02/SE-25 288941 12/144D02 32 Z-D02/SE-32 288942 12/144D02 35 Z-D02/SE-35 288943 12/144D02 40 Z-D02/SE-40 288944 12/144D02 50 Z-D02/SE-50 288945 12/144D02 63 Z-D02/SE-63 288946 12/144

Description Fuse-Links Z-D0./SE, Operating class gG (gL)

• According to DIN VDE 0636, DIN 49522• For Fuse-Switch-Disconnector Z-SLS, -SLK• For Fuse-Bases D0.-SO and Z-D02/R/3

Technical DataZ-D0./SE

ElectricalOperating class gG (gL)Rated voltage

AC 400 VDC 250 V

Rated frequency 45-65 HzRated insulation voltage Ui 2500 VRated short-circuit breaking capacity

AC 50 kADC 8 kA

MechanicalSize

D01 1, 2, 4, 6, 10, 13, 16 AD02 20, 25, 32, 35, 40, 50, 63 A

Characteristics Z-D0./SETime/current characteristics of Z-D0-Fuse-Links 2 ... 63A gG(gL) Let-through characteristics of Z-D0-Fuse-Links 2 ... 63A gG(gL)

310

210

110

010

-110

-210

-310

2 41

10 2 42

10 2 43

10 2 44

10

Schm

elz

ze

ittin

s

Unbeeinflusster Strom I in AP

Nennstrom I in AN2 4 6 10 16 20 25 35 50 63

2I 2P I 2P

20

10

4

2

1

0,4

0,2

0,1

0,1 0,2 0,4 1 2 4 10 20 100

Kurzschlussstrom I in kAP

Ne

nn

str

om

Iin

AN

2

4

6

10

16

20

25

35

50

63

Durc

hla

ssstr

om

Iin

kA

D

ß

Mtgrö

tem

Gle

ihst

rom

glie

d

i

c

One

Gle

ichst

rom

glie

d

h

Möglic

he

Sto

ßku

rzsc

hlu

ssst

röm

e

Prospective current IP in A

Vir

tual

pre

-arc

ing

time

t in

s

Let-

thro

ugh

curr

ent I

D in

kA

Prospective short-circuit current IP in kA

Rat

ed c

urre

nt I n

in A

Poss

ible s

hort-

circu

t pea

k cur

rent

sWith

large

st dir

ect c

urren

t com

pone

nt

Withou

t dire

ct curr

ent co

mponen

t

Rated current IN in A

1.174Fuse Devices

Cartridge-Ring Adapter Insert

174 EATON CORPORATION xxxxx+xxxx-xxxxEN

D0

Cartridge-Ring Adapter Insert

Size Rated current(A)

TypeDesignation

Article No. Units perpackage

SG81611 D01 2 Z-D01/PE-2 288909 12/288D01 4 Z-D01/PE-4 288910 12/288D01 6 Z-D01/PE-6 288911 12/288D01 10, 13 Z-D01/PE-10 288912 12/288D02 20 Z-D02/PE-20 288913 12/288D02 25 Z-D02/PE-25 288914 12/288D02 35, 32 Z-D02/PE-35 288915 12/288D02 40 Z-D02/PE-40 288916 12/288D02 50 Z-D02/PE-50 288917 12/288

• In practical plastic box in the color of the visual tripping indicator - to snap on DIN rail

Cartridge-Ring Adapter Insert Z-D0./PE

SG81511 D02-D01 2 Z-D02-D01/PE-2 263112 12/288D02-D01 4 Z-D02-D01/PE-4 263113 12/288D02-D01 6 Z-D02-D01/PE-6 263150 12/288D02-D01 10, 13 Z-D02-D01/PE-10 263151 12/288D02-D01 16 Z-D02-D01/PE-16 263152 12/288

• D01 for Fuse-Base D02 and Fuse-Switch-Disconnector D02• In practical plastic box in the color of the visual tripping indicator - to snap on DIN rail

Cartridge-Ring Adapter Insert Z-D02-D01/PE

Description Cartridge-Ring Adapter Insert Z-D0./PE, Z-D02-D01/PE

• According to DIN 49523• Used for current coding of D0.-SO, Z-D02/R/3, Z-SLS/CB

Technical DataZ-D0./PE, Z-D02-D01/PE

ElectricalRated current

D01 2 - 10 AD02 20 - 50 AD02-D01 2 - 16 A

1.175

175 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesScrew Caps, Adapter Spring, Cartridge-Ring Adapter Insert Plier

D0

Screw Caps Z-D0./SK

Size Rated current(A)

TypeDesignation

Article No. Units perpackage

wa_sg04013 D01 max. 16 Z-D01/SK 100650 20D02 max. 63 Z-D02/SK 100651 20

Description Screw Caps Z-D0./SK

• Used for D0.-SO, Z-D02/R/3• Adapter Spring Z-D02/SIKA-HF for application of D01 fuse-links into the screw cap Z-D02/SK available

Technical DataZ-D0./SK

ElectricalRated current

D01 max. 16 AD02 max. 63 A

MechanicalElectrical thread

D01 E14D02 E18

A complete and functioning D-fuse system consists of base + fuse-link + cartridge-ring adapter insert + screw cap.The cartridge-ring adapter insert is not required for the highest rated current of each size (D01...16A and D02...63A).

Practical Hint

Adapter Spring Z-D02/SIKA-HF

Size TypeDesignation

Article No. Units perpackage

wa_sg02612 D02-D01 Z-D02/SIKA-HF 263149 50/3000

• To apply D01-Fuse-Links into the screw cap Z-D02/SK

Cartridge-ring adapter insert plier Z-D0-PE-ZSG19707 D01, D02 Z-D0-PE-Z 114324 1 / 10

1.176Fuse Devices

Fuse-Links

176 EATON CORPORATION xxxxx+xxxx-xxxxEN

D

Fuse-Links

Size Rated current(A)

TypeDesignation

Article No. Units perpackage

SG19007 DII E27 2 Z-DII/SE-2A/GG 112125 5/500DII E27 4 Z-DII/SE-4A/GG 112126 5/500DII E27 6 Z-DII/SE-6A/GG 112127 5/500DII E27 10 Z-DII/SE-10A/GG 112128 5/500DII E27 16 Z-DII/SE-16A/GG 112129 5/500DII E27 20 Z-DII/SE-20A/GG 112130 5/500DII E27 25 Z-DII/SE-25A/GG 112131 5/500DIII E33 35 Z-DIII/SE-35A/GG 112135 5/500DIII E33 50 Z-DIII/SE-50A/GG 112136 5/500DIII E33 63 Z-DIII/SE-63A/GG 112137 5/500

• Rated voltage 500 V AC / 400 V DC

Fuse-Links Z-DII./SE../GG, Operating class gG (gL)

SG19107 DII E27 6 Z-DII/SE-6A/DZ 112120 5/500DII E27 10 Z-DII/SE-10A/DZ 112121 5/500DII E27 16 Z-DII/SE-16A/DZ 112122 5/500DII E27 20 Z-DII/SE-20A/DZ 112123 5/500DII E27 25 Z-DII/SE-25A/DZ 112124 5/500DIII E33 35 Z-DIII/SE-35A/DZ 112132 5/500DIII E33 50 Z-DIII/SE-50A/DZ 112133 5/500DIII E33 63 Z-DIII/SE-63A/DZ 112134 5/500

• Rated voltage 500 V AC / 400 V DC

Fuse-Links Z-DII./SE../DZ, Operating class DZ

Description Fuse-Links Z-DII./SE

• According to DIN EN 60269-1 (VDE 0636 Part 10), DIN EN 60269-3 (VDE 0636 Part 30), DIN VDE 0636-301, CEE 16, IEC/EN 60269-1, IEC/EN 60269-3• For Fuse-Bases DII-SO..., DIII-SO...

Technical DataZ-DII./SE

ElectricalOperating class gG (gL), DZRated voltage Un

AC 500 VDC 400 V

Rated frequency 45-65 HzInsulating class C-VDE0110Rated short-circuit breaking capacity at 1.1 x Un

AC 50 kA / cos = 0.2DC 8 kA / = 15 ms

Dimensions (mm)In (A) ØA ØB

DII for Fuse-Base E272 21.5 64 21.5 66 21.5 610 21.5 816 21.5 1020 21.5 1225 21.5 14

DIII for Fuse-Base E3335 27 1650 27 1863 27 20

1.177

177 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Links

D

Characteristics Z-DII./SE

Time/current characteristics of Z-DII-Fuse-Links 2 ... 63A gG(gL) Let-through characteristics of Z-DII-Fuse-Links 2 ... 63A gG(gL)

Prospective current Ip in A

Pre-

arci

ng ti

me

t in

s

Max

imum

val

ue o

f cur

rent

I D in

kA

Rat

ed c

urre

nt I n

in A

Prospective current Ip in A

Characteristics Z-DII./SE

Melting energy characteristics I2t/A of Z-DII-Fuse-Links 2 ... 63A gG(gL) Time/current characteristics of Z-DII-Fuse-Links 2 ... 63A DZ

Prospective current Ip in A

I2A

val

ue in

A2 (

s)

Pre-

arci

ng ti

me

t in

s

Prospective current Ip in A

1.178Fuse Devices

Gauge Ring, Screw-in Gauge Ring

178 EATON CORPORATION xxxxx+xxxx-xxxxEN

D

Gauge Ring Z-DII./PE

Size Rated current(A)

TypeDesignation

Article No. Units perpackage

wa_sg05908 DII E27 6 Z-DII/PE-6A 110398 50DII E27 10 Z-DII/PE-10A 110399 50DII E27 16 Z-DII/PE-16A 110790 50DII E27 20 Z-DII/PE-20A 110791 50DIII E33 16 Z-DIII/PE-16A 110796 50DIII E33 25 Z-DIII/PE-25A 110798 50DIII E33 35 Z-DIII/PE-35A 110799 50DIII E33 50 Z-DIII/PE-50A 110800 50

Description Gauge Ring Z-DII./PE

• Used for current coding of DII.-SO/...

Technical DataZ-DII./PE

ElectricalRated current

DII 6 - 20 ADIII 16 - 50 A

Screw-in Gauge Ring Z-DII./PSwa_sg03312 DII E27 2 Z-DII/PS-2A 112138 25/1500

DII E27 4 Z-DII/PS-4A 112139 25/1500DII E27 6 Z-DII/PS-6A 112140 25/1500DII E27 10 Z-DII/PS-10A 112141 25/1500DII E27 16 Z-DII/PS-16A 112142 25/1500DII E27 20 Z-DII/PS-20A 112143 25/1500DII E27 25 Z-DII/PS-25A 112144 25/1500DIII E33 35 Z-DIII/PS-35A 112145 25/850DIII E33 50 Z-DIII/PS-50A 112146 25/850DIII E33 63 Z-DIII/PS-63A 112147 25/850

Description Screw-in Gauge Ring Z-DII./PS

• Used for current coding of DII.-SO/...-PS

Technical DataZ-DII./PS

ElectricalRated current

DII 2 - 25 ADIII 35 - 63 A

Dimensions (mm)In (A) A B C D

DII for Fuse-Base E272 3/16” 6.5 17 244 3/16” 6.5 17 246 3/16” 6.5 17 2410 3/16” 8.5 17 2416 3/16” 10.5 17 2420 3/16” 12.5 17 2425 3/16” 14.5 17 24

DIII for Fuse-Base E3335 3/16” 16.5 17 2450 3/16” 18.5 17 2463 3/16” 20.5 17 24

1.179

179 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesScrew Caps CD, Z-DII./SK

D

Screw Caps CD, Z-DII./SK

Size Rated voltage(V AC)

TypeDesignation

Article No. Units perpackage

SG07608 DII E27 500 CD27 112148 50DIII E33 500 CD33 112149 6DIII E33 690 Z-DIII/SK-690 118904 3

Description Screw Caps CD, Z-DII./SK

• Used for DII.-SO

Technical DataCD, Z-DII./SK

ElectricalRated current

DII max. 25 ADIII max. 63 A

Rated voltageCD27 500 V AC / 400 V DCCD33 500 V AC / 400 V DCZ-DIII/SK-690 690 V AC

MechanicalElectrical thread

DII E27DIII E33

Dimensions (mm)In (A) A B C DCD27 E27 44 12 34CD33 E33 44 12 43Z-DIII/SK-690 43 65 12 43

A complete and functioning D-fuse system consists of – base for screw-in gauge ring + fuse-link + screw-in gauge ring + screw cap– base for gauge ring + fuse-link + gauge ring + screw capThe gauge ring is not required for the highest rated current of each size (DII ... 25 A and DIII ... 63 A).

Practical Hint

1.180Fuse Devices

Fuse-Links Z-C../SE Operating class gG (gL)

180 EATON CORPORATION xxxxx+xxxx-xxxxEN

CCylindrical Fuse-Links

Fuse-Links Z-C../SE Operating class gG (gL)

Rated current(A)

Rated voltage(V AC)

TypeDesignation

Article No. Units perpackage

SG01010

1 500 Z-C10/SE-1A/GG C10G1 10/5002 500 Z-C10/SE-2A/GG C10G2 10/5004 500 Z-C10/SE-4A/GG C10G4 10/5006 500 Z-C10/SE-6A/GG C10G6 10/5008 500 Z-C10/SE-8A/GG C10G8 10/50010 500 Z-C10/SE-10A/GG C10G10 10/50012 500 Z-C10/SE-12A/GG C10G12 10/50016 500 Z-C10/SE-16A/GG C10G16 10/50020 400 Z-C10/SE-20A/GG C10G20 10/50025 400 Z-C10/SE-25A/GG C10G25 10/50032 400 Z-C10/SE-32A/GG C10G32 10/500

Size 10x38

SG20507

2 690 Z-C14/SE-2A/GG C14G2 10/2004 690 Z-C14/SE-4A/GG C14G4 10/2006 690 Z-C14/SE-6A/GG C14G6 10/2008 690 Z-C14/SE-8A/GG C14G8 10/20010 690 Z-C14/SE-10A/GG C14G10 10/20012 690 Z-C14/SE-12A/GG C14G12 10/20016 690 Z-C14/SE-16A/GG C14G16 10/20020 690 Z-C14/SE-20A/GG C14G20 10/20025 690 Z-C14/SE-25A/GG C14G25 10/20032 500 Z-C14/SE-32A/GG C14G32 10/20040 500 Z-C14/SE-40A/GG C14G40 10/20050 500 Z-C14/SE-50A/GG C14G50 10/200

Size 14x51

SG20407

16 690 Z-C22/SE-16A/GG C22G16 10/49020 690 Z-C22/SE-20A/GG C22G20 10/49025 690 Z-C22/SE-25A/GG C22G25 10/49032 690 Z-C22/SE-32A/GG C22G32 10/49040 690 Z-C22/SE-40A/GG C22G40 10/49050 690 Z-C22/SE-50A/GG C22G50 10/49063 690 Z-C22/SE-63A/GG C22G63 10/49080 500 Z-C22/SE-80A/GG C22G80 10/490100 500 Z-C22/SE-100A/GG C22G100 10/490

Size 22x58

Description Fuse-Links Z-C../SE Operating class gG (gL)

• According to IEC 60269-1 and IEC 60269-2-1• For fuse-switch-disconnectors C10-SLS, VLC, C10-CCI

• Operating class gG (gL)

Technical DataZ-C10/SE, 10x38 Z-C14/SE, 14x51 Z-C22/SE, 22x58

ElectricalOperating class gG (gL) gG (gL) gG (gL)Rated voltage Un 1 - 16 A / 500 V AC 1 - 25 A / 690 V AC 16 - 63 A / 690 V AC

Z-DIII/SK-690 20 - 32 A / 400 V AC 32 - 50 A / 500 V AC 80 - 100 A / 500 V ACRated frequency 50 Hz 50 Hz 50 HzRated short-circuit breaking capacity 100 kA 100 kA 100 kA

Dimensions (mm)Type Size a bmax. c dmin. rZ-C10 10x38 38,0±0.6 10.5 10.3±0.1 6 1.5±0.5Z-C14 14x51 51.0+0.6/-1 13.8 14.3±0.1 7.5 2±0.5Z-C22 22x58 58,0+1/-2 16.2 22.2±0.1 11 2±0.5

1.181

181 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Links Z-C../SE Operating class gG (gL)

CCylindrical Fuse-Links

Max. Power loss

Operating class gG - Power dissipations 400 V / 500 V / 690 VRated current In max. 3 W according to IEC 60269-2

10x38max. 5 W according to IEC 60269-214x51

max. 9.5 W according to IEC 60269-222x58

1 0.552 0.90 1.454 1.45 1.606 1.55 1.958 1.05 1.4010 1.10 1.4512 1.55 1.9516 2.85 3.00 3.0520 2.80 3.15 3.4025 2.95 4.10 4.4032 3.00 4.80 5.1040 4.75 7.2050 4.95 7.6063 8,0080 8.20100 9.40

Characteristics Z-C10/SE, Operating class gG, 10x38Time/current characteristics of Z-C10-Fuse-Links 2 ... 32A gG(gL) Let-through characteristics of Z-C10-Fuse-Links 2 ... 32A gG(gL)

Prospective current Ip in A

Pre-

arci

ng ti

me

t in

s

Max

imum

val

ue o

f cur

rent

I D in

kA

Rat

ed c

urre

nt I n

in A

Prospective current Ip in A

Melting energy characteristics I2t/A of Z-C10-Fuse-Links 1 ... 32A gG(gL)

Prospective current Ip in A

I2A

val

ue in

A2 (

s)

1.182Fuse Devices

Fuse-Links Z-C../SE Operating class gG (gL)

182 EATON CORPORATION xxxxx+xxxx-xxxxEN

CCylindrical Fuse-Links

Characteristics Z-C14/SE, Operating class gG, 14x51

Time/current characteristics of Z-C14-Fuse-Links 2 ... 50A gG(gL) Let-through characteristics of Z-C14-Fuse-Links 2 ... 50A gG(gL)

Prospective current Ip in A

Pre-

arci

ng ti

me

t in

s

Max

imum

val

ue o

f cur

rent

I D in

kA

Rat

ed c

urre

nt I n

in A

Prospective current Ip in A

Melting energy characteristics I2t/A of Z-C14-Fuse-Links 2 ... 50A gG(gL)

Prospective current Ip in A

I2A

val

ue in

A2 (

s)

1.183

183 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesFuse-Links Z-C../SE Operating class gG (gL)

CCylindrical Fuse-Links

Characteristics Z-C22/SE, Operating class gG, 22x58

Time/current characteristics of Z-C22-Fuse-Links 16 ... 100A gG(gL) Let-through characteristics of Z-C22-Fuse-Links 16 ... 100A gG(gL)

Prospective current Ip in A

Pre-

arci

ng ti

me

t in

s

Max

imum

val

ue o

f cur

rent

I D in

kA

Rat

ed c

urre

nt I n

in A

Prospective current Ip in A

Melting energy characteristics I2t/A of Z-C22-Fuse-Links 16 ... 100A gG(gL)

Prospective current Ip in A

I2A

val

ue in

A2 (

s)

1.184Fuse Devices Photovoltaic

Fuse-Links ASFLC10-..A-gPV-SOL Photovoltaic Application

184 EATON CORPORATION xxxxx+xxxx-xxxxEN

Cylindrical Fuse-LinksC

Fuse-Links ASFLC10-..A-gPV-SOL Photovoltaic Application

Rated current(A)

Rated voltage(V DC)

TypeDesignation

Article No. Units perpackage

SG11008

2 1000 ASFLC10-2A-gPV-SOL PV-2A10F 10/5004 1000 ASFLC10-4A-gPV-SOL PV-4A10F 10/5006 1000 ASFLC10-6A-gPV-SOL PV-6A10F 10/5008 1000 ASFLC10-8A-gPV-SOL PV-8A10F 10/50010 1000 ASFLC10-10A-gPV-SOL PV-10A10F 10/50012 1000 ASFLC10-12A-gPV-SOL PV-12A10F 10/50016 1000 ASFLC10-16A-gPV-SOL PV-15A10F 10/50020 1000 ASFLC10-20A-gPV-SOL PV-20A10F 10/50025 900 ASFLC10-25A-gPV-SOL PV10M-25*) 10/500*) melamine instead of ceramic

Size 10x38

PV-fuse-link selection: Maximum DC Operating voltage of the fuse-link must be:

1.2 x Voc of string Rated current In of the fuse-link must be higher or equal than:

1.5 x IscIsc . . . . . . short circuit current of PV-moduleVoc . . . . . open circuit voltage of string

Description Fuse-Links ASFLC10-..A-gPV-SOL Photovoltaic Application

• According to IEC 60269-1 and IEC 60269-4• For fuse-switch-disconnectors FCFDC10DI

Technical DataASFLC10-..A-gPV-SOL, 10x38

ElectricalRated voltage Un 6 - 20 A / 1000 V DC

25 A / 900 V DCRated frequency –Rated short-circuit breaking capacity 30 kA = L/R 2 ms

Dimensions (mm)Type Size a bmax. c dmin. rASFLC10 10x38 38,0±0.6 10.5 10.3±0.1 6 1.5±0.5

Max.Power lossRated currentIn

[A]

Pre-arcing Joule integralL/R = 2 ms

[A2s]

Operating Joule integralL/R = 2 ms

[A2s]

Power lossat 0.7 x In

[W]

Power lossat InPd[W]

Weight

[g]

2 1.3 3.5 1.47 1.00 104 3.3 28 0.52 1.25 106 5.5 45 0.73 1.65 108 8 62 0.93 1.9 1010 11 88 1.06 2.3 1012 23 180 1.03 1.9 1016 35 270 1.00 2.5 1020 50 430 1.18 3.25 1025 75 620 1.25 3.45 10

1.185

185 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse Devices PhotovoltaicFuse-Links ASFLC10-..A-gPV-SOL Photovoltaic Application

Cylindrical Fuse-LinksC

Characteristics ASFLC10-..A-gPV-SOL, Photovoltaic Application

Time/current characteristics of ASFLC10-..A-gPV-SOL Fuse-Links 2 ... 25A

Prospective current Ip in A

Pre-

arci

ng ti

me

t in

s

1.186Fuse Devices

Solid-Links Z-NH-../TR

186 EATON CORPORATION xxxxx+xxxx-xxxxEN

NH

Solid-Links Z-NH-../TR

Size TypeDesignation

Article No. Units perpackage

wa_sg04413 00 Z-NH-00/TR 263114 3 / 1801 Z-NH-1/TR 263115 6 / 602 Z-NH-2/TR 263116 6 / 603 Z-NH-3/TR 263117 3 / 30

1.187

187 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesNH-Fuse-Links, 500 V AC, Z-NH

NH

NH-Fuse-Links, 500 V AC, Z-NH

Size Rated current(A)

TypeDesignation

Article No. Units perpackage

wa_sg03412 00 10 Z-NH-00/10 289998 300 16 Z-NH-00/16 289999 300 20 Z-NH-00/20 290000 300 25 Z-NH-00/25 290001 300 35 Z-NH-00/35 290002 300 40 Z-NH-00/40 290003 300 50 Z-NH-00/50 290004 300 63 Z-NH-00/63 290005 300 80 Z-NH-00/80 290006 300 100 Z-NH-00/100 290007 300 125 Z-NH-00/125 290008 300 160 Z-NH-00/160 290009 31 50 Z-NH-1/50 290010 31 63 Z-NH-1/63 290011 31 80 Z-NH-1/80 290012 31 100 Z-NH-1/100 290013 31 125 Z-NH-1/125 290014 31 160 Z-NH-1/160 290015 31 200 Z-NH-1/200 290016 31 250 Z-NH-1/250 290017 32 100 Z-NH-2/100 290018 32 125 Z-NH-2/125 290019 32 160 Z-NH-2/160 290020 32 200 Z-NH-2/200 290021 32 250 Z-NH-2/250 290022 32 315 Z-NH-2/315 290023 32 400 Z-NH-2/400 290024 33 250 Z-NH-3/250 290025 33 315 Z-NH-3/315 290026 33 400 Z-NH-3/400 290027 33 500 Z-NH-3/500 290028 33 630 Z-NH-3/630 290029 3

• Operating class gG (gL)

Description NH-Fuse-Links, 500 V AC, Z-NH

• Design according to ÖVE-SN 40, IEC 60269, VDE 0636, SEV 1066• Dimensions according to Austrian standard ÖNORM E-6020, DIN 43.620• NH-fuse-links of operating class gG/gL are used for line protection. They reliably disconnect overcurrent and short-circuit current above the permitted levels up to the nominal

breaking current. • gG/gL NH-fuse-links also protect electrical systems and equipment against the electrodynamic effects of high short-circuit currents.• Insulating bodies of steatite/corderite • Full contact blade of silver-plated copper• Double blow-out indicator (fl at indicator and centre indicator), live grips• Corrosion-proof• NH-fuse-links have a selectivity of 1:1.6 (ratio of the series-connected nominal currents), permitting optimum utilization and protection of line cross-sections.• Strict current limitation permits reduced mechanical dimensions of electrical systems• High breaking capacity of 120 kA

1.188Fuse Devices

NH-Fuse-Links, 500 V AC, Z-NH

188 EATON CORPORATION xxxxx+xxxx-xxxxEN

NH

Technical DataZ-NH-00/ Z-NH-1/ Z-NH-2/ Z-NH-3/

ElectricalRated voltage

AC 500 V 500 V 500 V 500 VDC 230 V 440 V 440 V 440 V

Nominal current 10-160 A 50-250 A 100-400 A 250-630 ARated frequency 45-62 Hz 45-62 Hz 45-62 Hz 45-62 HzNominal breaking capacity

AC 120 kA 120 kA 120 kA 120 kADC 25 kA 25 kA 25 kA 25 kA

Nominal breaking capacityIn = 10 A 1.1 W - - -16 A 1.6 W - - -20 A 1.7 W - - -25 A 1.9 W - - -35 A 3.0 W - - -40 A 3.5 W - - -50 A 4.6 W 5.4 W - -63 A 5.4 W 6.3 W - -80 A 5.1 W 7.2 W - -100 A 6.9 W 8.6 W 8.8 W -125 A 10.3 W 11.9 W 12.1 W -160 A 11.0 W 13.9 W 14.0 W -200 A - 15.2 W 15.2 W -250 A - 21.8 W 21.8 W 19.4 W315 A - - 23.7 W 23.7 W400 A - - 30.5 W 30.5 W500 A - - - 42.0 W630 A - - - 47,0 W

Dimensions (mm)Type Size A B C D E F G H KZ-NH-00/ up to 100 A 000 79 53 47 35 15 21 52 7.5 6

125 - 160 A 00 79 53 47 35 15 28 56 12 6Z-NH-1/ up to 160 A 1C 135 68 65 40 15 28 61 12 6

200 - 250 A 1 135 72 65 40 20 46 65 14 6Z-NH-2/ up to 250 A 2C 150 72 65 48 20 46 73 14 6

315 - 400 A 2 150 72 65 48 26 54 73 14 6Z-NH-3/ up to 400 A 3C 150 72 65 60 26 54 84 14 6

500 - 630 A 3 150 72 65 60 33 65 84 14 6

1.189

189 EATON CORPORATION xxxxx+xxxx-xxxxEN

Fuse DevicesNH-Fuse-Links, 500 V AC, Z-NH

NH

Let-through Current Characteristic, Current Limitation Diagram Correction Factor for DC Component

Time-Current Characteristics

The characteristic shows the limited let-through current values (peak values) depending on the prospective short-circuit current (r. m. s.) under unfavourable connection conditions and depending on the respective nominal current.

ID let-through currentIG declining DC componentIp prospective short-circuit currentIs surge short-circuit current = Ip··2=2 for cos=0, =1 for cos=1

a Surge short-circuit current without DC component ( = 1)

b Surge short-circuit current with maximum DC component ( = 2)

The time-current characteristics are valid at an ambient temperature of 20±5°C C and for the cable (line) cross-sections assigned in the regulations for test arrange-ments.

For NH-fuse-links 2 - 630 A operating class gL/gG

1.190Measuring Instruments

190 EATON CORPORATION xxxxx+xxxx-xxxxEN

wa_sg05811 wa_sg04911

1.191

191 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Power Meter EME

System Rated current TypeDesignation

Article No. Units perpackage

SG10007 1N 32 A EME1P32 167397 11N 32 A, MID cert. EME1P32MID 167398 13N 80 A EME3P80 167413 13N 80 A, MID cert. EME3P80MID 167414 13N 5 A, CT EME3PCT 167417 13N 125 A, MID cert. EME3P125MID 167416 1

Accessories Current Transformer

Z-MG/WAK: maximum cable diameter 21 mmZ-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm, cable diameter 23 mm / 30 mm

- according to type, see dimension diagramms

Communication moduless

Description TypeDesignation

Article No. Units perpackage

wa_sg00312 Communication module MBUS EMECMBUS 167420 1Communication module with MODBUS EMECMODB 167421 1

EMECMODB

Basic Devices

System Rated current TypeDesignation

Article No. Units perpackage

wa_sg05711 3N 63 A, MODBUS EME3P63BMODBUS 167409 1

1.192Measuring Instruments

Power Meter EME

192 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Power Meter single-phase 32 A, EME

• Digital active energy meter with measurement I - U - Hz - PF measurement of active instantaneous power, by IR side set up communication - 1 tariff - 1 S0

• Active energy-meters for single-phase alternating current with a, 7 digits counter. These meters have 1 S0 output generating pulses for remote processing of the acti-ve energy measurements for 1 tariff.

• Display LCD• For direct connection 32 A and 40 A• 7 digits for energy values indication• Accuracy class 1 for active energy according to EN 50470-3 (B)• Most attractive operating range current (Ist ... Imax)

- for direct connection 32 A = 0.020• The standard versions are designed to be combined with the communication module

• Active energy register zero setting (not for MID types)• Active energy register in T1 import/export• Instantaneous power active import/export display• Current RMS• Voltage RMS• Power factor• Frequency• FW release• FW checksum• 1 DIN modules wide (18 mm)

Technical DataEME1P32 EME1P32MIDdirect connection 32 A direct connection 32 A

Data according to EN 50470-1, EN 50470-3 and EN 62053-31General characteristicsHousing DIN 43880 1 moduleMounting EN 60715 DIN rail 35 mmDepth 70 mmReference standard according to active energy EN 50470-1-3, EN 62053-31FunctionConnectivity to single-phase network 2 wiresStorage of energy values and confi guration FRAM memory yesSupplyRated control feed voltage Un 230 V ACOperating range voltage 184 ... 276 VRated frequency fn 50 HzRated power dissipation (max.) Pv 8 (0.6) VA (W)Overload capabilityVoltage Un continuous 276 V

momentary (1 s) 300 VCurrent Imax continuous 32 A

momentary (10 ms) 960 ADisplayDisplay LCD 7 digits (2 decimals)

digit dimensions 6.00 mm x 3 mmActive energy: 1 display, 7-digit 0.00 ... 999999.9 kWhInstantaneous tariff measurement 1 display, 1-digit T1Display period refresh 1 sMeasuring accuracy at 23 ±1°C referred to nominal valuesActive energy and power according to EN 50470-3 ±1% (B)Measuring inputType of connection phase/N directOperating range voltage phase/N 184 ... 276 VCurrent Iref 5 ACurrent Imin 0.25 AOperating range current (Ist ... Imax) direct connection 0.02 ... 32 AFrequency 50 HzInput waveform alternatingStarting current for energy measurement (Ist) 20 mAPulse output S0 according to EN 62053-31Pulse output for active energy yesPulse quantity 1000 Imp/kWhPulse duration 90 msRequired voltage min. (max.) 5 ... 230 V AC/DC ±5% (5 ... 300 V AC/DC)Permissible current pulse ON (max. 230 V AC/DC) 90 mAPermissible current impuls OFF (leakage currrent

max. 230 V AC/DC)1 μA

1.193

193 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Technical Data (continue page)EME1P32 EME1P32MIDdirect connection 32 A direct connection 32 A

Optical interfacesFront side (accuracy control) LED 5000 Imp/kWhSafety according to EN 50470-1Indoor meter yesPollution degree 2Rated operational voltage 300 VAC voltage test EN 50470-3. 7.2 4 kVTest voltage 1.2/50 μs 6 kVProtection class EN 50470 IIHousing material fl ame resistance UL 94 V0Safety-sealing between upper and lower housing part no yesAdaptor for CommunicationPlug-and-play technology yesLAN Interface (TCP/IP) Ethernet 802.3 10/100 Mbps EMECLANModbus RTU, Ascii Interface RS-485 3 wires up to 19,200 bps EMECMODBM-Bus Interface RS-485 2 wires up to 9,600 bps EMECMBUSConnection terminalsType cage main current paths screw head Z +/- PZ1 POZIDRIVType cage pulse output blade for slotted screw 0.8 x 3.5 mmTerminal capacity main current paths solid min. (max.) 16 mm2

stranded wire with sleeve min. (max.) 16 mm2

Terminal capacity pulse outlet solid min. (max.) 0.15 (2.5) mm2

stranded wire with sleeve min. (max.) 0.15 (4) mm2

Environmental conditionsMechanical environment M1Electromagnetic environment E2Operative temperature -10 to +55 °CLimit temperature of transportation and storage -25 to +70 °CVibrations sinusoidal vibration amplitude at 50 Hz ±0.075 mmDegree protectionhousing when mounted in front (terminal) IP51*)/IP20

*) For the installation in a cabinet at least with IP51 protection

Dimensions (mm) Connection diagram

A Miniature Circuit Breaker of 32A or 40A is recommended.

1.194Measuring Instruments

Power Meter EME

194 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Power Meter three-phase, transformer 5 A, direct 80 A, EME

• Digital active and reactive energy-meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 (MID types: displays only active power).

• Active energy-meters for three-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote pro-cessing of the instantaneous energy active and reactive measurements for 2 tariffs.

• Green backlighted LCD• For direct connection 80 A, or for transformer .../5 A• For transformer primary current of 5 A to 10.000/5 A. Input is in 5 A increments• 8 digits - 8 display for energy values indication• Detection of connection errors (phase transposition)

• Accuracy class 1 for active energy and power according to EN 50470-3 (B)• Accuracy class 2 for reactive energy and power according to EN 62053-23• Most attractive operating range current (Ist ... Imax), for direct connection 80 A =

0.015 ... 80 A, for connection by CT .../5 A = 0.003 ... 5 A• The standard versions are designed to be combined with the communication module• Energy register zero setting (not for MID types)• Energy register for import and export• Instantaneous power active and reactive display (MID types: only active power)• Sealable terminal covers• 4 DIN modules wide (72 mm)

Technical DataEME3P80 EME3P80MID EME3PCTdirect connection 80 A direct connection 80 A CT connection till 10,000/5 A

Data according to EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31General characteristicsHousing DIN 43880 4 MU 4 MUMounting EN 60715 DIN rail 35 mm DIN rail 35 mmDepth 70 mm 70 mmReference standard according to active energy EN 50470-1-3 EN 50470-1-3

pulse output EN 62053-31 EN 62053-31FunctionConnectivity to single/three-phase network 2-4 wires 4 wiresStorage of energy values and confi guration digital display (EEPROM) yes yesDisplay tariffs identifi er for active and reactive energy T1 and T2 T1 and T2SupplyRated control feed voltage Un 230 V AC 230 V ACOperating range voltage 184 ... 276 V 184 ... 276 VRated frequency fn 50 Hz 50 HzRated power dissipation (max.) Pv 8 (0.6) VA (W) 8 (0.6) VA (W)Overload capabilityVoltage Un continuous: phase/phase 480 V 480 V

1 second: phase/phase 800 V 800 Vcontinuous: phase/N 276 V 276 V1 second: phase/N 460 V 460 V

Current Imax continuous 80 A 6 Amomentary (0.5 s) - 120 Amomentary (10 ms) 2400 A -

DisplayConnection errors and phase out discernible from phase-sequence indication PHASE Err PHASE ErrDisplay LCD 8 digits (2 decimals) 8 digits (2 decimals)

digit dimensions 6.00 mm x 3 mm 6.00 mm x 3 mmActive energy: 1 display, 8-digit tariffs 2 0.01 Wh 0.01 Wh+ display import or export (arrow) overfl ow 999999.99 MWh 999999.99 MWhReactive energy: 1 display, 8-digit tariffs 2 0.01 varh 0.01 varh+ display import or export (arrow) overfl ow 999999.99 Mvarh 999999.99 MvarhInstantaneous active power: 1 display, 3-digit 000 ... 999 W, kW or MW 000 ... 999 W, kW or MWInstantaneous reactive power: 1 display, 3-digit 000 ... 999 var, kvar or Mvar 000 ... 999 var, kvar or MvarInstantaneous tariff measurement 1 display, 1-digit T1 or T2 T1 or T2Transformer primary current - 5 ... 10,000 ADisplay period refresh 1 s 1 sMeasuring accuracy at 23 ±1°C referred to nominal valuesActive energy and power according to EN 50470-3 class 1: B class 1: BReactive energy and power according to EN 62053-23 class 2: 2% class 2: 2%

1.195

195 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Technical Data (continue page)EME3P80 EME3P80MID EME3PCTdirect connection 80 A direct connection 80 A CT connection till 10,000/5 A

Measuring inputType of connection direct transformer .../5 AVoltage Un phase/phase 400 V 400 V

phase/N 230 V 230 VOperating range voltage phase/phase 319 ... 480 V 319 ... 480 V

phase/N 184 ... 276 V 184 ... 276 VCurrent Iref 5 A -Current In - 5 ACurrent Imin 0.25 A 0.05 AOperating range current (Ist ... Imax) direct connection 0.015 ... 80 A -

transformer connection (CT) - 0.003 ... 6 ATransformer current primary current of the transformer - 5 ...10,000 A

smallest input step adjustment - in 5 A stepsFrequency 50 Hz 50 HzInput waveform sinusoidal sinusoidalStarting current for energy measurement (Ist) 15 mA 3 mAPulse output S0 according to EN 62053-31Pulse output for active and reactive energy T1 and T2 yes yesPulse quantity at direct connection 80 A 500 Imp/kWh -

depending on the transformer factor - 100-10-1 Imp/kWhPulse duration 30 ms ±2 30 ms ±2Required voltage min. (max.) 5 ... 230 V AC/DC ±5% (5 ... 300 V AC/DC) 5 ... 230 V AC/DC ±5% (5 ... 300 V AC/DC)Permissible current pulse ON (max. 230 V AC/DC) 90 mA 90 mAPermissible current impuls OFF (leakage currrent max. 230 V AC/DC) 1 μA 1 μAOptical interfacesFront side (accuracy control) LED 1000 Imp/kWh 10000 Imp/kWhSafety according to EN 50470-1Indoor meter yes yesPollution degree 2 2Rated operational voltage 300 V 300 VAC voltage test EN 50470-3. 7.2 4 kV 4 kVTest voltage 1.2/50 μs 6 kV 6 kVProtection class EN 50470 II IIHousing material fl ame resistance UL 94 V0 V0Safety-sealing between upper and lower housing part yes no noAdaptor for CommunicationPlug-and-play technology yes yesLAN Interface (TCP/IP) Ethernet 802.3 10/100 Mbps EMECLAN 10/100 Mbps EMECLANModbus RTU, Ascii Interface RS-485 3 wires up to 19,200 bps EMECMODB up to 19,200 bps EMECMODBM-Bus Interface RS-485 2 wires up to 9,600 bps EMECMBUS up to 9,600 bps EMECMBUSConnection terminalsType cage main current paths screw head Z +/- PZ2 POZIDRIV PZ1 POZIDRIVType cage pulse output blade for slotted screw 0.8 x 3.5 mm 0.8 x 3.5 mmTerminal capacity main current paths solid min. (max.) 1.5 (35) mm2 1 (4) mm2

stranded wire with sleeve min. (max.) 1.5 (35) mm2 1 (4) mm2

Terminal capacity pulse outlet solid min. (max.) 1 (4) mm2 1 (4) mm2

stranded wire with sleeve min. (max.) 1 (2.5) mm2 1 (4) mm2

Environmental conditionsMechanical environment M1 M1Electromagnetic environment E2 E2Operative temperature -10 to +55 °C -10 to +55 °CLimit temperature of transportation and storage -25 to +70 °C -25 to +70 °CRelative humidity (not condensation) 80% 80%Vibrations sinusoidal vibration amplitude at 50 Hz ±0.075 mm ±0.075 mmDegree protectionhousing when mounted in front (terminal)

IP51*)/IP20 IP51*)/IP20

*) For the installation in a cabinet at least with IP51 protection

1.196Measuring Instruments

Power Meter EME

196 EATON CORPORATION xxxxx+xxxx-xxxxEN

Dimensions (mm) Connection diagram

A Miniature Circuit Breaker of 80A is recommended.

Wire N needs to be connected to the meter.

Direct connection to 80 A

1.197

197 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Dimensions (mm) Connection diagram

Wire N needs to be connected to the meter.

Instructions for the connection of transformer countersA Miniature Circuit Breaker of 6A is recommended. Current transformers must not be operated with open terminals since dangerous high voltages might occur which may result in personal injuries and property damage. In addition to this, the transformers are exposed to thermal overload.

Connection through CT .../5 A to 10,000/5 A

1.198Measuring Instruments

Power Meter EME

198 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Power Meter three-phase 125 A, EME

• Digital active and reactive energy-meter with measurement of active and reactive instantaneous power, by IR side set up communication - 2 tariffs - 2 S0 (MID types: displays only active power).

• Active energy-meters for three-phase alternating current with either 2, 8 digits digital counters. These meters have 2 S0 output generating pulses for remote pro-cessing of the instantaneous energy active and reactive measurements for 2 tariffs.

• Green backlighted LCD• For direct connection 125 A• 8 digits - 8 display for energy values indication• Detection of connection errors (phase transposition)• Accuracy class 1 for active energy and power according to EN 50470-3 (B)

• Accuracy class 2 for reactive energy and power according to EN 62053-23• Most attractive operating range current (Ist ... Imax) for direct connection 125 A =

0.020 ... 125 A• The standard versions are designed to be combined with the communication module• Energy register zero setting (not for MID types)• Energy register for import and export• Instantaneous power active and reactive display (MID types: only active power)• Sealable terminal covers• 6 DIN modules wide (108 mm)

Technical DataEME3P125MIDdirect connection 125 A

Data according to EN 50470-1, EN 50470-3, EN 62053-23 and EN 62053-31General characteristicsHousing DIN 43880 6 MUMounting EN 60715 DIN rail 35 mmDepth 70 mmReference standard according to active energy EN 50470-1-3

reactive energy - pulse output EN 62053-23-31FunctionConnectivity to single/three-phase network 2-4 wiresStorage of energy values and confi guration digital display (EEPROM) yesDisplay tariffs identifi er for active and reactive energy T1 and T2SupplyRated control feed voltage Un 230 V ACOperating range voltage 184 ... 276 VRated frequency fn 50 HzRated power dissipation (max.) Pv 8 (0.6) VA (W)Overload capabilityVoltage Un continuous: phase/phase 480 V

1 second: phase/phase 800 Vcontinuous: phase/N 276 V1 second: phase/N 300 V

Current Imax continuous 125 Amomentary (10 ms) 3750 A

DisplayConnection errors and phase out discernible from phase-sequence indication PHASE ErrDisplay LCD 8 digits (2 decimals)

digit dimensions 6.00 mm x 3 mmActive energy: 1 display, 8-digit tariffs 2 0.01 Wh+ display import or export (arrow) overfl ow 999999.99 MWhReactive energy: 1 display, 8-digit tariffs 2 0.01 varh+ display import or export (arrow) overfl ow 999999.99 MvarhInstantaneous active power: 1 display, 3-digit 000 ... 999 W, kW or MWInstantaneous reactive power: 1 display, 3-digit 000 ... 999 var, kvar or MvarInstantaneous tariff measurement 1 display, 1-digit T1 or T2Display period refresh 1 sMeasuring accuracy at 23 ±1°C referred to nominal valuesActive energy and power according to EN 50470-3 class 1: BReactive energy and power according to EN 62053-23 class 2: 2%

1.199

199 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Technical Data (continue page)EME3P125MIDdirect connection 125 A

Measuring inputType of connection directVoltage Un phase/phase 400 V

phase/N 230 VOperating range voltage phase/phase 319 ... 480 V

phase/N 184 ... 276 VCurrent Iref 5 ACurrent Imin 0.25 AOperating range current (Ist ... Imax) direct connection 0.020 ... 125 AFrequency 50 Hz ±2%Input waveform sinusoidalStarting current for energy measurement (Ist) 20 mAPulse output S0 according to EN 62053-31Pulse output for active and reactive energy T1 and T2 yesPulse quantity at direct connection 80 A 500 Imp/kWhPulse duration 30 ms ±2Required voltage min. (max.) 5 ... 230 V AC/DC ±5% (5 ... 300 V AC/DC)Permissible current pulse ON (max. 230 V AC/DC) 90 mAPermissible current impuls OFF (leakage currrent max. 230 V AC/DC) 1 μAOptical interfacesFront side (accuracy control) LED 1000 Imp/kWhSafety according to EN 50470-1Indoor meter yesPollution degree 2Rated operational voltage 300 VAC voltage test EN 50470-3. 7.2 4 kVTest voltage 1.2/50 μs 6 kVProtection class EN 50470 IIHousing material fl ame resistance UL 94 V0Safety-sealing between upper and lower housing part yesAdaptor for CommunicationPlug-and-play technology yesLAN Interface (TCP/IP) Ethernet 802.3 10/100 Mbps EMECLANModbus RTU, Ascii Interface RS-485 3 wires up to 19,200 bps EMECMODBM-Bus Interface RS-485 2 wires up to 9,600 bps EMECMBUSConnection terminalsType cage main current paths screw head Z +/- PZ2 POZIDRIVType cage pulse output blade for slotted screw 0.8 x 3.5 mmTerminal capacity main current paths solid min. (max.) 1.5 (50) mm2

stranded wire with sleeve min. (max.) 1.5 (50) mm2

Terminal capacity pulse outlet solid min. (max.) 1 (4) mm2

stranded wire with sleeve min. (max.) 1 (2.5) mm2

Environmental conditionsMechanical environment M1Electromagnetic environment E2Operative temperature -10 to +55 °CLimit temperature of transportation and storage -25 to +70 °CRelative humidity (not condensation) 80%Vibrations sinusoidal vibration amplitude at 50 Hz ±0.075 mmDegree protectionhousing when mounted in front (terminal) IP51*)/IP20

*) For the installation in a cabinet at least with IP51 protection

1.200Measuring Instruments

Power Meter EME

200 EATON CORPORATION xxxxx+xxxx-xxxxEN

Dimensions (mm) Connection diagram

A Miniature Circuit Breaker of 125A is recommended.

Wire N needs to be connected to the meter.

1.201

201 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Description M-Bus interface EMECMBUS

• Additional communication modules for Energy-meter, Network analyzer and Power-meters

• Additional module for M-Bus connection for energy, power, V, I, cosj, frequency

• M-Bus according to EN1434• Suitable for both single-phase and three-phase energy meters• 1 DIN module wide (18 mm)

Technical DataEMECMBUS

Data according to EN 13757-1-2-3, IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2General characteristicsHousing DIN 43880 1 moduleMounting EN 60715 DIN rail 35 mmDepth 70 mmPower supplyPower supply through bus connectionFunctionSuitable for both single-phase and three-phase energy meters yesModbus interfaceHW Interface 2 lift terminalsSW protocol M-Bus according to EN1434Baudrate 300-9600 baudInterface to measuring instrumentHW Interface optical IR 2 (Tx, Rx)SW protocol proprietarySafety according to IEC 60950Pollution degree 2Overvoltage category IIRated operational voltage 24 ... 36 VAir gap in equipment 1.5 mm

on PCB (not coated) 1.5 mmMinimum creepage distance 2.1 mmTest voltage impulse (1.2/50 μs) 2.5 kV

50 Hz 1 min 1.35 kVHousing material fl ame resistance UL 94 V0Connection terminalsType cage main current paths screw head Z +/- PZ0 POZIDRIVTerminal capacity solid min. (max.) 0.15 (2.5) mm2

stranded wire with sleeve min. (max.) 0.15 (4) mm2

Environmental conditionsOperative temperature 0 to +55 °CLimit temperature of transportation and storage -25 to +70 °CRelative humidity (not condensation) 80%Vibrations sinusoidal vibration amplitude at 50 Hz ±0.25 mmProtection class acc. to IEC 60950 IIDegree of protection, housing when mounted in front IP20

Dimensions (mm)

1.202Measuring Instruments

Power Meter EME

202 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Modbus Interface RTU and Ascii EMECMODB

• Additional communication modules for Energy-meter, Network analyzer and Power-meters

• Additional module for Modbus RTU and Ascii connection for energy, power, V, I, cosj, frequency

• Protocols Modbus Ascii - Modbus RTU• Suitable for both single-phase and three-phase energy meters• 1 DIN module wide (18 mm)

Technical DataEMECMODB

Data according to IEC 60950, EN 61000-6-2, EN 61000-6-3 and EN 61000-4-2General characteristicsHousing DIN 43880 1 moduleMounting EN 60715 DIN rail 35 mmDepth 70 mmSupplyRated control feed voltage Un 230 V ACAuxiliary power rating 10 WAuxiliary voltage range 0.80 ... 1.20 V AC x Un

Rated frequency 50/60 HzFrequency range 45 ... 65 HzFunctionProtocol selectable by software Modbus RTU or AsciiSuitable for both single-phase and three-phase energy meters yesModbus interfaceHW Interface RS-485 3 terminals (+/-, cable shielded)Input resistance 1 UL (12 k)Termination resistance 80 SW protocol selectable by software Modbus Ascii - Modbus RTUData transfer speed selectable by software 38,400 baud - default: 19,200 baudParity none/even - default: noneAddressing 1 to 247Interface to measuring instrumentHW Interface optical IR 2 (Tx, Rx)SW protocol proprietarySafety according to IEC 60950Pollution degree 2Overvoltage category IIRated operational voltage 300 VAir gap 4 mmMinimum creepage distance 4 mmTest voltage impulse (1.2/50 μs) with AC-Supply 2.5 kV

impulse (1.2/50 μs) telecommunication network 1.5 kV50 Hz 1 min 2.5 kV

Housing material fl ame resistance UL 94 V0Connection terminalslift terminals screw head Z +/- PZ0 POZIDRIVTerminal capacity solid min. (max.) 0.15 (2.5) mm2

stranded wire with sleeve min. (max.) 0.15 (4) mm2

Environmental conditionsOperative temperature 0 to +55 °CLimit temperature of transportation and storage -25 to +70 °CRelative humidity (not condensation) 80%Vibrations sinusoidal vibration amplitude at 50 Hz ±0.25 mmProtection class acc. to IEC 60950 IIDegree of protection, housing when mounted in front IP20

Dimensions (mm)

1.203

203 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsPower Meter EME

Description Basic Power Meters three-phase, 63 A, EME

• Digital active energy meter with partial active energy counter resettable and inbuilt communication Modbus RTU- 2 tariffs

• Three-phase digital active energy-meter with direct connection 0.25-5 (63) A, and inbuilt communication Modbus RTU - 2 tariffs

• For direct connection 63 A• 9 digits for 8 energy indication values• Detection of connection errors (phase transposition and phase missing)• Accuracy class 1 for active energy and power according to EN 50470-3 (B)

• Most attractive operating range current (Ist ... Imax), for direct connection 63 A = 0.015 ... 63 A

• Energy register zero setting (not for MID types)• Energy register “Partial” zero setting also for MID types• Sealable terminal covers• Energy register for delivery and supply• 4 DIN modules wide (72 mm)

Technical DataEME3P63BMODBUSdirect connection 63 A

Data according to EN 50470-1. EN 50470-3 and EN 62053-31General characteristicsHousing DIN 43880 4 MUMounting EN 60715 DIN rail 35 mmDepth 70 mmReference standard according to active energy EN 50470-1-3

pulse output EN 62053-31FunctionConnectivity to three-phase network 4 wiresStorage of energy values and confi guration digital display (EEPROM) yesDisplay tariffs identifi er for active energy T1 and T2SupplyRated control feed voltage Un 230 V ACOperating range voltage 184 ... 276 VRated frequency fn 50 HzRated power dissipation (max.) Pv 8 (0.6) VA (W)Overload capabilityVoltage Un continuous: phase/phase 480 V

1 second: phase/phase 800 Vcontinuous: phase/N 276 V1 second: phase/N 300 V

Current Imax continuous 80 Amomentary (10 ms) 2400 A

DisplayConnection errors and phase out discernible from phase-sequence indication PHASE ErrDisplay LCD 9 digits (2 decimals)

digit dimensions 6.00 mm x 3 mmActive energy: 1 display, 9-digit tariffs 2 0.01 Wh+ display import or export (arrow) overfl ow 9999999.99 MWhReactive energy: 1 display, 8-digit tariffs 2 0.01 varhInstantaneous tariff measurement 1 display, 1-digit T1 or T2Display period refresh 1 sMeasuring accuracyactive energy according to EN 50470-3 class 1: BMeasuring inputType of connection directVoltage Un phase/phase 400 V

phase/N 230 VOperating range voltage phase/phase 319 ... 480 V

phase/N 184 ... 276 VCurrent Iref 5 ACurrent Imin 0.25 AOperating range current (Ist ... Imax) direct connection 0.015 ... 63 AFrequency 50 HzInput waveform sinusoidalStarting current for energy measurement Ist 15 mA

1.204Measuring Instruments

Power Meter EME

204 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical Data (continue page)EME3P63BMODBUSdirect connection 63 A

Optical interfacesFront side (accuracy control) LED 1000 Imp/kWhSafety according to EN 50470-1Indoor meter yesPollution degree 2Rated operational voltage 300 VAC voltage test EN 50470-3. 7.2 4 kVTest voltage 1.2/50 μs 6 kVProtection class EN 50470 IIHousing material fl ame resistance UL 94 V0Safety-sealing between upper and lower housing part yesAdaptor for CommunicationModbus RTU RS-485 3 wires up to 19,200 bpsConnection terminalsType cage main current paths screw head Z +/- PZ2 POZIDRIVType cage pulse output blade for slotted screw 0.8 x 3.5 mmTerminal capacity main current paths solid min. (max.) 1.5 (35) mm2

stranded wire with sleeve min. (max.) 1.5 (35) mm2

Terminal capacity pulse outlet solid min. (max.) 1 (4) mm2

stranded wire with sleeve min. (max.) 1 (2.5) mm2

Environmental conditionsMechanical environment M1Electromagnetic environment E2Operative temperature -10 to +55 °CLimit temperature of transportation and storage -25 to +70 °CRelative humidity (not condensation) 80%Vibrations sinusoidal vibration amplitude at 50 Hz ±0.075 mmDegree protectionhousing when mounted in front (terminal) IP51*)/IP20

*) For the installation in a cabinet at least with IP51 protection

Dimensions (mm) Connection diagram

Wire N needs to be connected to the meter.

A Miniature Circuit Breaker of 63A is recommended.

1.205

205 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsMultimeter EME3PMMCT5

Multimeter EME3PMMCT5

Communication link TypeDesignation

Article No. Units perpackage

SG14413 S0 EME3PMMCT5 171631 1

1.206Measuring Instruments

Multimeter EME3PMMCT5

206 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Multimeter EME3PMMCT5

• The Eaton Multimeter offer an extremely compact multifunction solution for switch-gear and incoming or outgoing feeders in industrial plants and buildings like offi ces, hospitals, universities and so on

• Can be connected to three phase networks via current transformers (.../5A till 10.000/5A)

• Three phase 38 readouts, imported and exported power• Clear readable LED display that reports all measurements through a user-friendly

interface controlled directly from the front panel• Analysis of the different loads on each phase to identify displacements, asymmetri-

cal or unbalanced conditions

• Offers a range of different options to combine and assess measured values• Provided with 2 S0 outputs report active and reactive energy• Two different tariffs settled by an external energy counter (Wh and VArh)• With a side IrDA interface for external communication• External communication allows for the transmission of measured values to a remote

energy management system• 6 modules housing for DIN rail mounting• User can display continuously fi ve indicated values

Technical DataEME3PMMCT5

Communication link S0Connection .../5 AHousing (width) 6 DIN modulesMeasuring voltage range 50 .., 276 / 87 .., 480 V ACFrequency range 49 .., 51 HzStarting current Ist 3 mAReference current Iref 5 AMain supply auxiliary 184 .., 276 V ACSystem connectivity 2 - 3 - 4 wiresDisplay LEDDisplay green backlighted yesMain terminal 4 mm2

Operative temperature -10 to +55 °CPulse output SO 2Measuring accuracy

EN 50470-1-3 active energy class 1: B (1%)EN 62053-23 reactive energy class 2: 2%

Voltage L1, L2, L3

L1-2, L2-3, L3-1

Current L1, L2, L3

N

Power factor L1, L2, L3

L

Frequency

Effective power L1, L2, L3

L

Reactive power L1, L2, L3

L

Apparent power L1, L2, L3

L

Import active energy L1, L2, L3, L

tariff 1 and 2

Export active energy L1, L2, L3, L

tariff 1 and 2

Import reactive energy L1, L2, L3, L

tariff 1 and 2

Export reactive energy L1, L2, L3, L

tariff 1 and 2

Communication ()IR-side: M-Bus, Modbus RTU, KNX, LAN-TCP/IP, SD-Card yes

= Measured parameters displayed, = Measured parameters through IR side modules

1.207

207 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsLAN Server Modbus/TCP EMELSMODBUS

LAN Server Modbus/TCP EMELSMODBUS

Description TypeDesignation

Article No. Units perpackage

SG14313 Data Concentrator with Modbus/TCP EMELSMODBUS 170509 1

1.208Measuring Instruments

LAN Server Modbus/TCP EMELSMODBUS

208 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description LAN Server Modbus/TCP EMELSMODBUS

Overview:The LAN Servers are Plug-and-Play data concentrators for Energy Meter, Network Analyzer and Power Meter products. The LAN Server allows an easy and reliable connection of several instruments to a data communication network. It is an innovative product designed to implement fast data communication between a supervisory PC and a set of measurement instruments connected through LAN, WAN or Internet. Instruments may be of different kinds and are automatically recognized through a unique coding.

LAN Server Modbus/TCP:This Plug-and-Play product collects the measurement data from different devices connected via a Modbus serial bus. Data are made available on LAN, WAN or Intranet through an HTTP interface and are accessible using simultaneously a standard browser or a Modbus/TCP Application.The LAN Server Modbus/TCP requires an auxiliary at 230 V AC power supply.

Common features• Worldwide communication with measuring devices• Hardware connection through RJ45• TCP/IP data protocol• HTTP for web server• FTP for fi le transfer• NTP for time synchronization• Static or DHCP based addressing• DDNS to maintain a host name, accessible on the internet, without the need for a

static IP• Plug-and-play technology• Internet browser user interface, three languages• Password-protected site access• Internal memory: 2 Gigabytes available for long period storage• 4 DIN modules wide (72 mm)

Technical DataEMELSMODBUS

Type LAN Server Modbus/TCPDescription Data Concentrator with Modbus/TCPAccording to norm general EN 61000-6-2-3, EN 61000-4-2 yesAccording to norm general EN 60950Device width 4 modulesPower supplyVoltage range 230 V AC ±20 %Auxiliary power rating 10 VAFrequency range 45 ... 65 HzOperation featureMemory storage internal 2 GigabyteLAN - HW Interface RJ 45LAN - SW Protocol TCP/IPLAN - Bandrate 10/100 Mbit/sApplication level protocols HTTP - FTP - Modbus/TCPInterface to instruments RS485HW Interface 3 Screw-type terminalsSW Protocol Modbus RTU and ASCIIDirectly connected instruments 31S0 impulse input –Safety accoording to IEC 60950Pollution degree 2Overvoltage category IIOperating voltage ... 300 VACTest voltage impulse

(1.2/50 μs) peak value 4 kV50 Hz 1 min 4 kV

Environmental conditionOperative temperature -10 to 55 °CLimit temperature of storage -25 to 70 °CRelative humidity (non condensing) 80%Vibrations amplitude at 50 Hz ±0.25 mmProtection class IIDegree of protection IP20

1.209

209 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsAmmeter and Voltmeter digital EM

Ammeter and Voltmeter digital EM

Description TypeDesignation

Article No. Units perpackage

wa_sg00212 Ammeter EMA20 167423 1Voltmeter EMV600 167422 1

Accessories Current Transformer

Function Ratio/Measuring Range TypeDesignation

Article No. Units perpackage

SG8797 Current transformer for cable 40/5 Z-MG/WAK-40 101619 1Current transformer for cable 50/5 Z-MG/WAK-50 101620 1Current transformer for cable 60/5 Z-MG/WAK-60 101621 1Current transformer for cable 80/5 Z-MG/WAK-80 101622 1Current transformer for busbar 100/5 Z-MG/WAS-100 101623 1Current transformer for busbar 150/5 Z-MG/WAS-150 101625 1Current transformer for busbar 200/5 Z-MG/WAS-200 101626 1Current transformer for busbar 250/5 Z-MG/WAS-250 101627 1Current transformer for busbar 300/5 Z-MG/WAS-300 101628 1Current transformer for busbar 400/5 Z-MG/WAS-400 101629 1Current transformer for busbar 500/5 Z-MG/WAS-500 101630 1Current transformer for busbar 600/5 Z-MG/WAS-600 101631 1Current transformer for busbar 800/5 Z-MG/WAS-800 101632 1Current transformer for busbar 1000/5 Z-MG/WAS-1000 101624 1

• Z-MG/WAK: maximum cable diameter 21 mm• Z-MG/WAS: maximum busbar cross section 30 x 10 mm, 40 x 10 mm or 50 x 12 mm, cable diameter 23 mm / 30 mm - according to

type, see dimension diagramms

Description Ammeter EMA20 - Voltmeter EMV600

• Digital measuring instruments offer greater readout immediacy for the value displayed. They also offer the advantage of having no moving parts which are subject to wear over the long term, an issue which can affect the precision and reliability of the instrument.

• Voltmeter AC• Ammeter AC• 2 DIN modules wide (36 mm)

1.210Measuring Instruments

Ammeter and Voltmeter digital EM

210 EATON CORPORATION xxxxx+xxxx-xxxxEN

Technical DataVoltmeter AmmeterEMV600 EMA20

Data according to EN 61010-1, EN 61000-6-2, EN 61000-6-3General characteristicsHousing DIN 43880 2 MU 2 MUMounting EN 60715 DIN rail 35 mm DIN rail 35 mmDepth 70 mm 70 mmReference standard DIN 43751-1-2 DIN 43751-1-2SupplyVoltage 230 V AC 230 V ACOperating range voltage 0.90 ... 1.15 V AC 0.90 ... 1.15 V ACRated frequency 50/60 Hz 50/60 HzOperating range frequency 45 ... 65 Hz 45 ... 65 HzPower rating 2 VA 2 VAOverload capabilityVoltage Un continuous 1.2 V x voltage rating -

momentary (1 s) 1.3 V x voltage rating -Current Ib/In continuous - 1.1 A x Currentbereich

momentary (1 s) - 10 A x CurrentbereichDisplayVoltage 3 digits h = 10 mm 12 ... 600 V -

Voltage >600 V HHH -Voltage <12 V ---- -

Current 3 digits h = 10 mm - 0.4 ... 20 A (a)0.1 ... 5 A (b) (CT operation)

Current >10 A - 20 A/5 A - HHH(connection CT)Current <0.1 A - 0.2 A - 0.4 A - ---(connection CT)

Display period refresh 4 readout/s 4 readout/sMeasuring accuracy at 23 ±1°C referred to nominal valuesVoltage ±1% ±1 Digit -Current - ± 0.5% ±1 DigitTemperature (deviating) ±0.03% for °C ±0.03% for °CMeasuring inputType of connection direct direct (a)(b < 5 A),

with CT .../5 A (b)Voltage Un 600 V -Measurement range voltage 12 ... 600 V -Current Ib/In - 20 A (a), 5 A (b)Measurement range current - 0.2 ... 10 (b),

(0.1 ... 5) x transformer ratio (b)Rated frequency 50 Hz 50 HzMeasurement range frequency 45 ... 65 Hz 45 ... 65 HzInput waveform synus. symmetric synus. symmetricSafety according to EN 61010-1Pollution degree 2 2Overvoltage category II IIRated operational voltage 300 V 600 VMaterial group II IIAir gap 3.0 1.5Minimum creepage distance in equipment 4.3 2.1

on printed wiring boards (not coated) 3.0 1.5Test voltage impulse (1.2/50 μs) 4 kV 2.5 kV

50 Hz 1 min 2.2 kV 1.35 kVHousing material fl ame resistance UL 94 V0 V0Connection terminalsType cage screw head Z +/- PZ1 POZIDRIV PZ1 POZIDRIVTerminal capacity solid min. (max.) 1 (6) mm2 1 (6) mm2

stranded wire with sleeve min. (max.) 1 (6) mm2 1 (6) mm2

Environmental conditionsOperative temperature -10 to +55 °C -10 to +55 °CLimit temperature of transportation and storage -40 to +70 °C -40 to +70 °CRelative humidity (not condensation) 80% 80%Vibrations sinusoidal vibration amplitude at 50 Hz ±0.25 mm ±0.25 mmProtection class according to EN 61010-1 II IIDegree of protection (terminals) IP40 (IP20) IP40 (IP20)

1.211

211 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsAmmeter and Voltmeter digital EM

Dimensions (mm) Connection diagram

1.212Measuring Instruments

Ammeter and Voltmeter digital EM

212 EATON CORPORATION xxxxx+xxxx-xxxxEN

Description Current transformer for cable Z-MG/WAK, Current transformer for busbar Z-MG/WAS

• Transform high currents to standard measuring currents• Current transformers help to cut costs when installing and connecting busbar system• Recommended from 40 A upward• Accuracy classes

Class 0.5: for accurate measurement and calibrated kWh-metersClass 1: for general measurement and non-calibrated kWh-metersClass 3: for coarse measurement, relays and for protection

• When winding several turns of the primary cable around the current transformer, you will receive half the primary current per turn while power and class remain unchanged.

Technical DataZ-MG/WAK Z-MG/WAS

ElectricalMax. Rated operational voltage 720 V 720 VSecondary current 5 A 5 ARated frequency 50-60 Hz 50-60 HzCable diameter 21 mm 23 mm, 30 mmBusbar cross section – 30 x 10 mm, 40 x 10 mm, 50 x 12 mmPrimary nominal current IpN class P [VA] class P [VA]

40 A 3 1.350 A 3 1.560 A 3 1.580 A 3 2100 A 1 1.5150 A 1 3200 A 1 3250 A 0.5 2300 A 0.5 2400 A 0.5 3500 A 0.5 10600 A 0.5 10800 A 0.5 101000 A 0.5 10

Connections P1 (K) primary input, P2 (L) primary output, s1 (k) secondary input, s2 (l) secondary outputNominal thermic short-time current Ith 60 x IpN for 1 s 60 x IpN for 1 sNominal dynamic short circuit current Idyn 2.5 x Ith for 1 s 2.5 x Ith for 1 sPermanent overload 1.2 x IpN 1.2 x IpN

Insulating class IEC 85 E ETest voltage 50 Hz / 1 min. 6 kV 6 kVMechanicalMounting quick fastening on DIN rail IEC/EN 60715.

wall mounting,directly onto the cable or onto busbar

Degree of protection IP30 IP30Secondary connection plug-in terminals 6.3 mm plug-in terminals 6.3 mmPermitted relative air humidity 80% 80%Temperature range -20 to +50 °C -20 to +50 °CMax. temperature of busbars – 70 °C

Dimensions (mm)

Connection diagram

1.213

213 EATON CORPORATION xxxxx+xxxx-xxxxEN

Measuring InstrumentsOperating Hours Counter ASOHC230

Operating Hours Counter ASOHC230

Display Rated voltage TypeDesignation

Article No. Units perpackage

wa_sg04411 5+2 digit 230 V 50Hz ASOHC230 167424 1

Description Operating Hours Counter ASOHC230

• The operating hours counter registers the operating hours to an accuracy of two decimals (hundredths of a second).• Power supply for terminals 1 and 3 of the electronic counter is required to enable the device to continuously display the measured values. If terminal 3 is supplied with voltage

(at DC “+“), the counting process will get started. • In case of a power failure, the counting result will be saved for an indefi nite period of time (EEPROM). Once power is back again, counting will be continued from the value that

has been saved before.• Time counters are used for a reliable collection of production and service hours, which allows an accurate planning and monitoring of production processes, maintenance cycles

and warranty periods.

Technical DataASOHC230

Standards DIN VDE 0435-110, DIN EN 60255-6, UL 863Approvals UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55Rated control feed voltage Uc 230 V ACAuxiliary voltage range at 50/60 Hz 0.9 ... 1.1 x Uc

Rated frequency 50 HzAuxiliary power rating Pv <1 VAType of operation counting of hoursDisplay Cyclometer register 00000,00 hConnection terminals ±screws (Philips) 1Terminal capacity solid 1.5 mm2

stranded wire with sleeve min. 0.75 mm2

Permitted ambient temperature -10 ... +70 °CDegree of protection according to DIN EN 60529 IP20, with conductors connectedProtection class according to DIN EN 61140 / VDE 0140 IIAllowed range of air humidity <80 %

Connection diagram

Dimensions (mm)

1.214Measuring Instruments

Pulse Counter ASPC230

214 EATON CORPORATION xxxxx+xxxx-xxxxEN

Pulse Counter ASPC230

Display Rated voltage TypeDesignation

Article No. Units perpackage

wa_sg05011 7 digits 230 V 50Hz ASPC230 167425 1

Description Pulse Counter ASPC230

• The pulse counter sums up the number of pulses, e.g. how many times a device is switched on.• Power supply for terminals 1 and 3 of the electronic counter is required to enable the device to continuously display the measured values. If terminal 3 is supplied with voltage (at

DC “+“), the counting process will get started.• In case of a power failure, the counting result will be saved for an indefi nite period of time (EEPROM). Once power is back again, counting will be continued from the value that has

been saved before.• Pulse counters are used for a reliable collection of production and service hours, which allows an accurate planning and monitoring of production processes, maintenance cycles

and warranty periods.• Pulse counting is used for general quantity counting, registration of the switch-on frequency, and for the collection of switch-on cycles or production quantities in systems and

machines.

Technical DataASPC230

Standards DIN VDE 0435-110, DIN EN 60255-6, UL 863Approvals UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55Rated control feed voltage Uc 230 V ACAuxiliary voltage range at 50/60 Hz 0.9 ... 1.1 x Uc

Rated frequency 50/60 HzAuxiliary power rating Pv <1 VAType of operation counting of pulsesDisplay Cyclometer register 0000000

LCD display -- h--

Frequency of counting 10 HzPulse duration 50 msResetting electrical components --

mechanical components --Connection terminals ±screws (Philips) 1Terminal capacity solid 1.5 mm2

stranded wire with sleeve min. 0.75 mm2

Permitted ambient temperature -10 ... +70 °CDegree of protection according to DIN EN 60529 IP20, with conductors connectedProtection class according to DIN EN 61140 / VDE 0140 IIAllowed range of air humidity <80 %

Dimensions (mm)

Connection diagram

1.215

215 EATON CORPORATION xxxxx+xxxx-xxxxEN

Other Accessories

sg68912 138103900

1.216Other Accessories

Protective Earth Socket Z-SD230

216 EATON CORPORATION xxxxx+xxxx-xxxxEN

Protective Earth Socket Z-SD230

Design TypeDesignation

Article No. Units perpackage

sg68912 Standard Z-SD230 266875 10 / 50Child protection device and earth pin Z-SD230-BS 266876 10 / 50

Accessories Busbar Block Busbar Z-SV-10/1P+N-SD 269526 10

End caps Z-V-AK/2+3P 264930 10 / 600

Description Protective Earth Socket Z-SD230

• Design according to VDE, ÖVE• Modular busbar connection system L/N• Screw fastening is possible• Width 2.5MU• Busbar block Z7-SD/1P+N 10 mm2 available• Model -BS with child protection device and earth pin

Technical DataZ-SD230

ElectricalRated voltage 250 V ACRated current 10/16 AMechanicalFrame size 45 mmDevice height 76 mmDevice width 44 mmMounting quick fastening on DIN rail IEC/EN 60715, screw-mounting possibleDegree of protection, built-in IP40Upper and lower terminals lift terminalsTerminal capacity 1 to 2x2.5 mm2

Connection diagram

Dimensions (mm)Z-SD230 Z-SD230-BS

1.217

217 EATON CORPORATION xxxxx+xxxx-xxxxEN

Other AccessoriesNeutral Conductor Lead-Through Terminal, Feed Terminal Z-D

Neutral Conductor Lead-Through Terminal, Feed Terminal Z-D

Rated current / Design TypeDesignation

Article No. Units perpackage

SG59511 63 A Z-D63 248267 12/12063 A with test socket Z-D63/P 248268 12/120100 A Z-D80 248269 12/120

Description Neutral Conductor Lead-Through Terminal, Feed Terminal Z-D

• Compatible with standard busbar to Xtra Combination devices• Z-D80: Feeder block for busbar system 80 A. Lift terminal (35 mm2) and open mouthed terminal above, lift terminal (50 mm2) below. Busbar positioning optionally above or below• Z-D80: with testing bush 4 mm Ø, 10 A for N-conductor

Technical DataZ-D63 Z-D63/P Z-D80

ElectricalRated current 63 A 63 A 100 AFrequency 50-60 Hz 50-60 Hz 50-60 HzN-conductor test bush – 10 A, Ø 4 mm –MechanicalFrame size 45 mm 45 mm 45 mmDevice height 80 mm 80 mm 80 mmDevice width 17.5 mm (1MU) 17.5 mm (1MU) 17.5 mm (1MU)Mounting quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protection, built-in IP40 IP40 IP40Terminals

above open mouthed/lift terminals open mouthed/lift terminals open mouthed/lift terminalsbelow open mouthed/lift terminals open mouthed/lift terminals lift terminals

Terminal capacityabove 1-25 mm2 1-25 mm2 1-35 mm2

below 1-25 mm2 1-25 mm2 2.5-50 mm2

Busbar thickness 0.8 - 2 mm 0.8 - 2 mm 0.8 - 2 mm

Connection diagramZ-D63 Z-D63/P Z-D80

Dimensions (mm)Z-D63 Z-D63/P Z-D80

1.218Other Accessories

Front Plate Tripping Device Z-MFPA

218 EATON CORPORATION xxxxx+xxxx-xxxxEN

Front Plate Tripping Device Z-MFPA

TypeDesignation

Article No. Units perpackage

SG58911 Z-MFPA 248302 6 / 60

Description Front Plate Tripping Device Z-MFPA

• Mechanical tripping device for PXF, PXK, FAZ, PLSM, CLS, Z-A40, PKNM and PKDM, responds when the front plate of a distribution box is removed• Maximum tripping capacity: 4 + 4 poles symmetrically• Can be interlocked by twisting when the tripping pin is in the pressed position

Technical DataZ-MFPA

MechanicalFrame size 45 mmDevice height 80 mmDevice width 17.5 mmMounting quick fastening on DIN rail IEC/EN 60715Degree of protection, built-in IP40

Function Diagram

Dimensions (mm)

Function

1.219

219 EATON CORPORATION xxxxx+xxxx-xxxxEN

Other AccessoriesCircuit Description GR, Plastic Box Z-BOX

Circuit Description GR

Number of Circuits Dimensions(mm)

TypeDesignation

Article No. Units perpackage

138103900 30 210x120 GR-2 138103900 190 210x300 GR-3 138104100 1

• Self-adhesive table for synoptic description of circuits, to be attached inside or on a distribution box.• Pre-printed individual adhesive labels for device designation included

Plastic Box Z-BOX

Colour Dimensions(mm)

TypeDesignation

Article No. Units perpackage

SG81411 blue 45x54x75 Z-BOX/BLA 286062 12/120

• Empty, can be snapped onto DIN rail• For spare fuse links, small spare parts