SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB Revision: 06 Document Revision Remark: Any modification of SEB content will be not informed in advance.Document Revision Revision Comment Issued Date Approved Date 00 new document for all previous versions Yanchunming 2011-08-23 Xuyong 2011-08-23 01 Change the speed from 0.63 to 0.5 Change HWmin(550/630kg) from 1875 to 1900. Yanchunming 2012-05-30 Xuyong 2012-05-30 02 P22,change ISC function from option to standard lizhigang 2012-9-29 Xuyong 2012-9-29 03 Add hoistway HW & HD Max lizhigang 2012-10-15 Dongdawei 2012-10-15 04 P14 Enclose panel add hairline304/SCME /SCME-hairline304 P14 Door jamb add hairline304 P14 Front add hairline304/mirror P16 Car door add hairline304/mirror P18 hoistway door add SCME Change E1000 to SIGMA MRL E1000 lizhigang 2013-1-15 Dongdawei 2013-01-15 05 Add (mirror DL>450KG) to optional decoration of car ceiling in C-EL1 & C-EL2 Add mirror to HR02 for handrail type Add remark for hoistway lighting Revise the description about car fan & light power controlling in standard functions Revise power supply for SIGMA MRL E1000 Huzhimin 2013-03-18 Dongdawei 2013-03-18 06 Added the adorning thickness P18 Huzhimin 2013-09-04 Dongdawei 2013-09-04

Upload: hoangphuc

Post on 08-Jul-2018

351 views

Category:

Documents


5 download

TRANSCRIPT

SIGMA MRL E1000

Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Document Revision

(Remark: Any modification of SEB content will be not informed in advance.)

Document Revision

Revision Comment Issued Date Approved Date

00 new document for all previous

versions Yanchunming 2011-08-23 Xuyong 2011-08-23

01

Change the speed from 0.63 to 0.5

Change HWmin(550/630kg) from 1875

to 1900.

Yanchunming 2012-05-30 Xuyong 2012-05-30

02 P22,change ISC function from option

to standard lizhigang 2012-9-29 Xuyong 2012-9-29

03 Add hoistway HW & HD Max lizhigang 2012-10-15 Dongdawei 2012-10-15

04

P14 Enclose panel add

hairline304/SCME /SCME-hairline304

P14 Door jamb add hairline304

P14 Front add hairline304/mirror

P16 Car door add hairline304/mirror

P18 hoistway door add SCME

Change E1000 to SIGMA MRL E1000

lizhigang 2013-1-15 Dongdawei 2013-01-15

05

Add (mirror DL>450KG) to optional

decoration of car ceiling in C-EL1 &

C-EL2

Add mirror to HR02 for handrail type

Add remark for hoistway lighting

Revise the description about car fan &

light power controlling in standard

functions

Revise power supply for SIGMA MRL

E1000

Huzhimin 2013-03-18 Dongdawei 2013-03-18

06 Added the adorning thickness P18 Huzhimin 2013-09-04 Dongdawei 2013-09-04

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 1 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

SIGMA MRL E1000 SEB

Standard Equipment Binder

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 2 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

CONTENTS

1. Description of the Integral Product 3

2. Elevator Integral Components and Illustration 9

3. Performance 22

4. Executive Standards and Codes 22

5. Function Introduction 23

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 3 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

1. Description of the Integral Product

Commercial Name: SIGMA MRL E1000

Original Source of the Product:

SIGMA MRL E1000 series are manufactured by Express Elevator CO. Ltd.

SIGMA MRL E1000 Series Model codes:

P0450G05D-CO P0450G10D-CO -- --

-- P0550G10D-CO P0550G15D-CO P0550G17D-CO

-- P0630G10D-CO P0630G15D-CO P0630G17D-CO

-- P0800G10W-CO P0800G15W-CO P0800G17W-CO

-- P1000G10W-CO P1000G15W-CO P1000G17W-CO

P0250G05D-2S P0250G10D-2S -- --

P0320G05D-2S P0320G10D-2S -- --

P0450G05D-2S P0450G10D-2S -- --

-- P0550G10D-2S P0550G15D-2S P0550G17D-2S

-- P0630G10D-2S P0630G15D-2S P0630G17D-2S

-- P0800G10D-2S P0800G15D-2S P0800G17D-2S

-- P1000G10D-2S P1000G15D-2S P1000G17D-2S

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 4 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Explanation For The Model Codes:

SIGMA MRL E1000 model code is composed of 11 characters.

Numerical digit1: indicates the type of the elevator (P means passenger lift)

Numerical digit 2-5: means the duty load.

For example, 0630 means that the duty load is 630kg.

1000 means the duty load is 1000kg.

Numerical digit 6: executive code and standards.

G means GB series.

Numerical digit 7& 8: brief mark of rated speed.

06-0.63m/s; 10-1.0m/s; 15-1.5m/s; 17-1.75m/s;

Numerical digit 9: car size. W – wide car; D– deep car.

Numerical digit 10-11: door type.

standard:CO---center opening; 2S---side opeining

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 5 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

For example:

P 1000 G 15 W CO

Center opening

Wide car

Rated Speed 1.5m/s

GB series

Duty load is 1000kg

Passenger lift

SIGMA MRL E1000 Duty Load, Passengers and Car Dimensions

Center Opening

Side Opening

Duty Load

(kg)

DL

Passengers

NBPAS

Car inside dimension (mm)

CARSZ

Width

CW

Depth

CD

450 6 1000 1100

550 7 1100 1300

630 8 1100 1400

800 10 1400 1350

1000 13 1600 1400

Duty Load

(kg)

DL

Passengers

NBPAS

Car inside dimension (mm)

CARSZ

Width

CW

Depth

CD

250 3 800 900

320 4 900 1000

450 6 1000 1100

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 6 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

SIGMA MRL E1000 Rated Speed

Load

(kg)

DL

Passengers

NBPAS

Speed

(m/s)

V

250 3 0.5 1.0 N/A N/A

320 4 0.5 1.0 N/A N/A

450 6 0.5 1.0 N/A N/A

550 7 N/A 1.0 1.5 1.75

630 8 N/A 1.0 1.5 1.75

800 10 N/A 1.0 1.5 1.75

1000 13 N/A 1.0 1.5 1.75

SIGMA MRL E1000 Max. Rise and Max. Stops

Duty Load

(kg)

DL

Speed

(m/s)

V

Maximum extra weight

for local linings

(kg)

MAXWT 0.5 1.0

250-450

30m 30m

100 FCL FCL

10 stops 10 stops

Duty Load

(kg)

DL

Speed

(m/s)

V

Maximum extra

weight for local

linings

(kg)

MAXWT 1.0 1.5 1.75

550-1000

60m 75m 90m

200 FCL FCL FCL

20 stops 24 stops 30 stops

If the decorative weight is over standard, contract engineering is must.

550 7 1100 1300

630 8 1100 1400

800 10 1200 1500

1000 13 1100 2100

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 7 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Max. Number of elevators in group control

Elevator

Type

ELVTYPE

Speed

m/s

Number of

elevators in group

control

SIGMA MRL

E1000

0.5

4 1.0

1.5

1.75

The Minimum Rise For Elevator To Reach Rated Speed

Elevator Type

ELVTYPE

Speed

(m/s)

V

The minimum rise

for elevator to

reach rated

speed(m)

SIGMA MRL

E1000

0.5 4

1.0 5

1.5 6

1.75 7

Minimum Floor Height

Elevator Type

ELVTYPE

Door opening

height(mm)

OPH

Single door

(mm)

Minimum distance

between front & rear

door panles

(mm)

SIGMA MRL

E1000 2100 2700 600

Motion Control Type and Drive System

Type

ELVTYPE Model

Load

(kg)

DL

Passengers

NBPAS

Speed

(m/s)

V

SIGMA MRL

E1000

P0250G05D 250 3

0.5

P0250G10D 1.0

P0320G05D 320 4 0.5

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 8 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

P0320G10D 1.0

P0450G05D 450 6

0.5

P0450G10D 1.0

P0550G10D

550 7

1.0

P0550G15D 1.5

P0550G17D 1.75

P0630G10D

630 8

1.0

P0630G15D 1.5

P0630G17D 1.75

P0800G10W/D

800 10

1.0

P0800G15W/D 1.5

P0800G17W/D 1.75

P1000G10W/D

1000 13

1.0

P1000G15W/D 1.5

P1000G17W/D 1.75

Power Supply for SIGMA MRL E1000

Main Power(VAC)

3 phase

Light power(VAC)

1 phase Frequency(Hz)

Standard Voltage 380±7% 220±7% 50/60

Optional Voltage

380±7% 230±7% 50/60

415±7% 240±7% 50/60

400±7% 220±7% 50/60

400±7% 230±7% 50/60

400±7% 240±7% 50/60

208±7% 110±7% 50/60

220±7% 110±7% 50/60

208±7% 120±7% 50/60

Arrangement of Machine Room

Machine location: without machine room

Machine type: gearless machine

Roping factor: 2:1

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 9 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

2. Elevator Integral Components and Illustration

Equipments In Machine Room

1. Controller

SIGMA MRL E1000 controller is EXP-MCS-5

2.EXP-GM VTR Machine, Motor, Coder

3. Machine standand beam

Welded channel steel & “H” steel are used for SIGMA MRL E1000, including isolation pad &

installation parts.

4. Governor

According to speed and rise, the following types of governor are selected for SIGMA MRL E1000.

Model

Load

(kg)

DL

Speed

(m/s)

V

Machine

Rated

rotate

Speed

(rpm/min.)

Roping

Ratio

Sheave

Diameter

(mm)

Groove Undercut

Kinds

Deflection

Pulley

Motor

Power

(kW)

P0250G05D 250

0.5

KDS

58

2:1

330 3

U

Without

1.1

P0250G10D 1.0 116 330 3 2.2

P0320G05D 320

0.5 58 330 3 1.1

P0320G10D 1.0 116 330 3 2.2

P0450G05D 450

0.5 58 330 4 1.5

P0450G10D 1.0 116 330 4 3.0

P0550G10D

550

1.0

GTW8

96 400

4

Without

4.5

P0550G15D 1.5 144 400 6.8

P0550G17D 1.75 167 400 7.9

P0630G10D

630

1.0 96 400

4

4.5

P0630G15D 1.5 144 400 6.8

P0630G17D 1.75 167 400 7.9

P0800G10W/D

800

1.0 96 400

4

5.5

P0800G15W/D 1.5 144 400 8.3

P0800G17W/D 1.75 167 400 9.6

P1000G10W/D

1000

1.0 96 400

5

6.7

P1000G15W/D 1.5 144 400 10

P1000G17W/D 1.75 167 400 11.7

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 10 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

The detailed information is shown in the following form:

Load

(kg)

DL

Rope Dia

(mm)

250~1000 6.3

5. Rope Fastening

SIGMA MRL E1000 has hitch plates that are mounted in the overhead. The rope fastening

type is wedge-shape, so that it is convenient for installation and the rope length can be

adjusted.

6. Switches

SIGMA supplies the switches including main power switch, car lighting switch, hoistway

lighting switch and breaker with creepage protection. Different specifications can be chosen

according to the different working current.

7. Headroom wiring

SIGMA MRL E1000 headroom wirings are supplied by Express, which include the wiring

connection:

Main power switch------Controller

Lighting switches------Controller

Controller------Motor brake

Controller------Coder

Controller------Speed governor

Controller------Handwheel switch

8. Safety Marks

Every unit of SIGMA MRL E1000 elevator provides a set of safety marks in order to comply

with SIGMA WWJSSS standard.

9. Others

The hooks, lightings, ventilation, daylight and temperature-control devices in hoistway and

steel used for pre-installation are prepared by customers.

Hoistway Equipment

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 11 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

1. Guide Rail

The guide rail complies with ISO standard and Chinese construction professional standard.

The specification of guide rails used are shown in the form as below:

Load

(kg)

DL

Speed

(m/s)

V

Guide rail Model CWT Rail

Arrangement Car side

(linear density kg/m)

Counterweight side

(linear density kg/m)

250

0.5/1.0

T82 TK3A

Side

arrangement

320 T82 TK3A

450 T82 TK3A

550

1.0/1.5/1.75

T89 TK3A

630 T89 TK3A

800 T89 TK3A

1000 T89 TK3A

Note: CAR rail is solid type, CWT rail is hollow type.

2. Rail Brackets

The rail brackets of SIGMA MRL E1000 are welded rail brackets and are adjusted by cutting

at jobsite. The rail brackets can be adjusted according to the hoistway size.The rail bracket

spacing is 2000mm.

3. Guide Rail Stand

SIGMA MRL E1000 rail stand is bending plate.

4. Buffer

Please refer to SIGMA MRL E1000 technical specification table for the detail specifications

of buffer.

Speed

(m/s)

V

Buffer

Type

0.5 Polyurethane

Buffer

1.0 Polyurethane

Buffer

1.5 Oil Buffer

1.75 Oil Buffer

5. Buffer Stand

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 12 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

SIGMA MRL E1000 provides buffer stands according to pit depth. It uses bending plate

structure. Please refer to layout drawing for the pit depth.

6. Governor Tension Device

If the maximum rise is below or equal to 60m, the governor rope tension weight is 30kg. If

the maximum rise is above 60m and below or equal to 90m, the tension weight is 48kg.

7. Cunterweight

Load

(kg)

DL

Speed

(m/s)

V

DBG(mm)

Filler Sheave

Diamete

r

(mm)

Guide

Rail

Type

CWT Width

(mm) Weight

(kg)

Width

(mm)

250 0.5/

1.0 600 23 190 330

Slide

Guide

330 320

450

550 1.0/

1.5/

1.75

1000 48 208 400 208 630

800

1000

Note: Above is based on standard filler, but iron filler could be applied as deviation.

8. Pit Material

The pit material consists of pit lighting, emergency stop switch, hoistway lighting switch. All

the wirings adopt AMP quick-assembly connectors.

9. Traction Rope & Governor Rope

Traction rope use 10mm steel wire rope.(When DL<=450kg, the rope is 8mm)

governor rope use 6.3mm steel wire rope.

10. Hoistway lighting

Lamps are provided along the hoistway with a spacing of 7m.

Two lamps have to be placed at 0.5m above top of hoistway and 0.5m above pit respectively

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 13 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

The lighting switch is set in the controller and pit respectively.

Remark : If lighting power isn’t 220VAC, factory supply hoistway lamp wire, local should

provide hoistway lamps & lamps holders.

11. Compensation Chain

The immersion plastics chain is used for SIGMA MRL E1000.

Car

1. Car Frame

SIGMA MRL E1000 car frame is shaped with bending sheet and bolts assembled. It includes

platform support frame. The platform support frame can be used as installation platform

when installation.

Crosshead Hitch

Safety Block is assembled at foot of frame. It is manufactured according to SIGMA

Specification.

Guide shoe, select sliding guide.

The balance weight to be used if required.

2. Platform

The platform of SIGMA MRL E1000 is shown in the below figure.

The enclosure is assembled at the side of platform with pop nut and bolts. The car threshold

is made of aluminum alloy with dust holes left. The thickness of floor decoration is 3mm, and

the process of standard floor decoration is sticking wood board on floor sheet and then

sticking floor hide (FL01M, FL02M, FL03M, FL04M, FL05M, FL06M, FL07M, FL08M). There

are no floor tile and wooden plate in the optional decoration, The thickness of floor

decoration is 30mm.

SIGMA MRL E1000 uses mechanical three points weighting device with micro-action switch.

3. Top of car Protection

Protection rails

The middle pole is at the position of half height.

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 14 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

4. Enclosure Panel, SCME-hairline443,SCME Ceiling, Car Door, Header, Hanger, and Door

Operator

Components Standard Option

Enclosure

panel

Bending shaped

Welded steel stiffener at back, painted surface

With visible ventilation hole at the bottom of front

panel

Hairline 443/Hairline304/

SCME-hairline443/SCME

[EST002] ;[EST003] ;[EST004] ;[

EST005] ;[EST006] ;[EST007] ;[

EST008] ;[EST009] ;[EST010] ;[

EST011] ;[EST012] ;[EST013] ;[

EST014] ;[EST015]

NOTE :

Only open type is CO ,

SCME /SCME-hairline443 can

choose

8 colors to select:

P-001, P-002, P-003, P-004, P-005, P-006, P-007,

P-010

SCME

–hairline443 --------

NOTE:

When choose SCME

–hairline443 type, front

panel must be hairline443

SCME -------

NOTE:

When choose SCME type, front

panel must be mirror

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 15 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Door jamb The color of ordinary steel door jamb is same with

enclosure panel. Hairline 443/hairline304

Front panel Same color with enclosure panel.

Without second COP cutout.

Hairline443/hairline304/mirror

NOTE: Mirror only use when

choose SCME type, otherwise

Mirror can’t choose

Height of car Inside height = 2300mm Inside height =2400mm

Ventilation Install a cross-flowing blower on top of car.

Standard disposition is one set. -----

Lighting C-ES1 type ceiling with lamps for lighting.. -----

Emergency lighting device is standard equipment. -----

Car roof

C-ES1 type ceiling without suspend ceiling, sprayed

& painted (8 colors available are same as enclosure

wall)

C-EL1(Mirror DL>450KG) type

with decorative ceiling

C-EL2(Mirror DL>450KG) type

with decorative ceiling.

Emergency

exit ----- With emergency exit

Handrail -----

HR-04 stainless steel mirror

single tube

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 16 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

-----

HR-02 stainless steel mirror

double tube

Car door

protective

device

2D light curtain -----

Car door Steel painted, same as enclosure

Hairline443/Hairline304/MIrror

NOTE:

1:When choose SCME

–hairline443 type,Car door must

be Hairline443

2:When choose SCME type,Car

door must be Mirror, otherwise

Mirror can’t choose

Header and

hanger

Structural lintel with door operator pre-mounted.

Hanger is assembled on header. -----

Door operator Use manufacturer’s variable frequency door

operator. -----

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 17 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

5.Car and Hall Signal Fixtures

Components Standard

Hall Call

HB/HPI

VIL-EM1C

Car operation panel

COP

CBM-EM1C

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 18 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Position Reference system

Model & speed

(m/s)

Functio

n

Material Type Location

1.0&1.5&1.75

Control system

PRS

FLS

Sensor On crosshead of car

Limit switch On brackets supported by the guide

rails

Limit switch cam On brackets supported by the car

frame uprights

Hoistway door system

Components & funciton Standard Option

Door panel

Ordinary painting sheet Hair

Hairline443/Hairline304/SCME

[EST002] ;[EST003] ;[EST004] ;[E

ST005] ;[EST006] ;

[EST007] ;[EST008] ;[EST009] ;[E

ST010] ;[EST011]

;[EST012] ;[EST013] ;[EST014] ;[E

ST015]

NOTE : Only open type is CO , SCME

can choose

Painted color:

P-001, P-002, P-003, P-004, P-005,

P-006, P-007, P-010

Door panel fire protection

request Non-fireproofing Fire-proofing door

Entrance frame

Ordinary painting sheet

Hair Hair-line stainless steel Painted color:

P-001, P-002, P-003, P-004, P-005,

P-006, P-007, P-010

Sill Aluminum alloy sill ----

Landing adorning thickness

Standard adorning thickness Optional

≤80mm 80<Landing adorning thickness≤150mm

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 19 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Layout Feature and Hoistway Dimension

Feature Limitation Use for

Machine location Without machine room

Roping factor 2:1

CWT location Side All models

Door service Only front door

Floor height Min. 2700 mm

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 20 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Dimension of hoistway

HW

HD

Load

(kg)

DL

Car

spec.

HW

Min. size

(mm)

HW

Max. size

(mm)

HD

Min. size

(mm)

HD

Max. size

(mm)

Opening

type

Door opening size

(width*depth) mm

250 Deep car 1450 1770 1300 1650 2S 700X2100

320 Deep car 1550 1870 1350 1700 2S 700X2100

450 Deep car 1650 1970 1450 1800 CO 700X2100

450 Deep car 1650 1970 1450 1800 2S 800X2100

550 Deep car 1900 2180 1700 2200 CO 800X2100

550 Deep car 1850 2180 1750 2250 2S 800X2100

630 Deep car 1900 2180 1800 2300 CO 800X2100

630 Deep car 1850 2180 1850 2350 2S 900X2100

800 Wide car 2150 2480 1750 2250 CO 800X2100

800 Deep car 1950 2280 1950 2450 2S 900X2100

1000 Wide car 2350 2680 1800 2300 CO 900X2100

1000 Deep car 1850 2180 2550 3050 2S 900X2100

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 21 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

Dimension of vertical profile

R = rise,unit: m

K: Overhead

S: Pit depth

Load

(kg)

DL

Speed

(m/s)

V

CH size

(mm)

K min. size

(mm)

S min. size

(mm)

250~450kg 0.5~1.0 2300 3800

1250 2400 3900

550~1000kg

1.0 2300 3800

1350 2400 3900

1.5 2300 3950

1500 2400 4050

1.75 2300 4000

1500 2400 4100

Note: Please contact with our factory, if the size of ”CH size” don’t contain in this table.

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 22 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

3. Performance

SIGMA MRL E1000 Performance

Speed tolerance ±5%

Car vertical vibration 25 mg

car horizontal

vibration15 mg

one meter from sound source

one meter from ground

Max. door noise <=65 dB(A)

Leveling accuracy ± 5 mm

<=55 dB(A) (fans off)

<=70 dB(A)

In center of car and 1 meter high

from ground of car

Standard

Peak value to peak value,

measured with PMT instrument

Instrument or test method

Noise in machine

room(max.)

Max. noise in car

4. Executive Standards and Codes

GB 7588-2003

The SIGMA Worldwide Job-site Safety Standard ( WWJSSS )

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 23 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

5. Function Introduction

S for Standard ,O for Optional

Fundtion

code Function name

Usefulne

ss Function introduction Notes

FCL Full collective

operation S

All registered car & hall calls will be answered in the

sequence by which the elvator cars approaches the

landings. The travel direction of car will be determined by

the first registered car or hall call.

Top of car

inspection &

machine room

inspection

S

Inspection operation switches, inspection buttons &

emergency stop device are provided at car top &

machine room. Car top inspection has priority over

machine room inspection. When inspection mode is

started, only inspection operation is allowed.

ECU Emergency car

light S

When the normal lighting power fails, the emergency

lingting works.

CHT

Separate Car and

Hall Call Door

Times

S The time of door retaining open for answering hall call

and car call can be adjusted separately.

LNS Load non stop S

When a car is loaded to a presetted percentage of its

rated load, it is considered as “full”,.the car will bypass

further hall calls. The hall calls will be registered and will

be anwered on next trip (single),or by another car(group).

ARD Automatic return

to main floor S

Main stop may be set according to real need of buildings

for single elevator. Car will automatically return to main

stop if no call is registered during presetted time, and

door remains close before answering futher hall call.

Main stop is usually at busy-traffic floors or ground floor.

Fan manual &

light automatic

switching

S

The car fan is controlled by COP switch and the light

power is controlled by software according to running

status of the elevator

Faulty automatic

detection S The system will automatically detect faulty

DTP

Door closing

overtime

protection

S

When the door can’t close properly within persetted time

due to mechanical barriers or other reasons, elevators

will not in operation if no door-closed signal is detected

after door repeats closing for three times.

OLD Overload warning S When the car is overloaded, the alarm light and buzzer

works. Then overloading is indicated , car door will not

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 24 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

close, and elevator will not operate.

TRIC Trip counter S

A counter is arranged in elevator control cabinet to count

times elevator oerates for the convenience of

maintanence.

Alarm Bell S For passengers in special case to press alarming

buttonin to inform outside in time.

HPI

/CPI

Hall & car

position indicator S

A digital number is displayed on the COP and landing call

box indicated for passengers to know the car position in

the hoistway.

HTTL

/CTTL

Hall & car call

register S

When the hall call or car call is registered, the button LED

illuminates.

HDI

/CDI

Hall & car

direction indicator S

To be convenient for passengers to learn the operation

direction of car, arrowhead indicator lamp to indicate

operation direction is arranged on car operation panel

and hall calling faceplate.

Light curtain S Light curtain is provided as door closing safety device.

ICU

Intercom

between security

room and car /

machine room

S

Intercom between surveillance room and machine room

and car(including car top/pit) is offered, effective still at

power failure.

EFO Emergency

firemen operation S

When fireman switch is on , the system will cancel all

calls, drive elevators to return to fire-fighting floor directly,

opens door to release passengers and stop operation

Emergency

rescue in

controller

S When elevator encounters barriers, operate the

emergency rescue in controller to rescue the passengers.

DOB/DCB Door open &

close button S

Micro-button has been set in the operation panel in the

car, in order to help passengers control the time to open

or close the door according to their demands.

ISC Independent

service S

When elevator stays at independent service, which has

ben designed to meet special needs of customers, it will

no longer answer calls from out of hoistway but only

operate, close & open door under manual control.

PKS Parking

Operation O

Each elevator will have a key switch 'PKS' at a

designated landing (e.g., at the lobby). By this feature, a

particular car may be commanded by its key switch to the

designated landing.

ATT Attendant service O The Attendant Operation feature allows semi-automatic

operation with manual control.

RLEV Relevelling O Stopping errors shall be corrected by relevelling. The size

SIGMA MRL E1000 Doc No.: SIGMA MRL E1000_ENG_SEB

Revision: 06

Page: 25 / 25 Standard Equipment

Binder

(Remark: Any modification of SEB content will be not informed in advance.)

operation of a possible stopping error depends on the type of drive

and the accuracy of the position sensors.

GNC Gong in car O

A chime installed on car top will ring when the car

approaches landing to remind passengers that they have

arrived at the destination floor.

CCTVC CCTV cable O CCTV cable from car to machine room is offered

Voice Synthesis O

When the car arrives at floor or ready to move, the

system will announce about the floor number and running

direction by artificial voice.

ANS Anti-Nuisance O

If there is only one passenger in the car and an excessive

number of car calls is registered, such nuisance is

detected and all car calls will be canceled, requiring

registration of a proper number of calls.

Fire Alarm Home

Landing O

When gire alarm system in a building is actirated, the car

will return to appointed floor immediately. And send

such signal to customer.

BA Interface O

By using a contact the elevator signal such as floor,

up-down, fault, over-load, fire alarm etc. will be sent to

custome Building Automation room.

Elevator

Supervisory

Panel

O

Monitor panel will be provided, and the elevator

operation situaiton ( running , overload, door opening,

fire alarm, fault ) will be monitored

Elevator Monitor

System With PC O

By PC system, to monitor the elevator operartion,

including floor , running direction, door opening.,

overload, fire alarm, fault

ARED

Automatc

Emergency

Rescue Device

O

When the power failure come suddenly, if the elevator

has not arrived at the appointed foor, the ARED device

will activate the car to reach nearest floor and open the

door; if the car already arrived at the floor, the door will

open by ARED

THB Machine

Overheat Protect O

Once the machine temperature is over 120℃, the

elevator will out of service after this run. When the

machine temperature is below 120℃, the elevator will

become normal accordingly.