WH AT IS A DMA?
A District Metered Area (DMA)is a small area of distribution system whichis specifically defined
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
3/27
To monitor the performance of the area byvarious indicators: W ater balance, NR W% , NR W volume Level of leakage
For Active Leakage Control activities Critical areas can be prioritized the for leak
detection
For Pressure management (where possible) Eliminating excess pressure Reducing leakage volume
WHY DO W E NEED TO H AVE DMAs?
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
4/27
Selection criteria 500 to 2000 connections 5km to 20 km Sufficient pressure Ability to hydraulically isolate area
GIS roles in pre-selection of area
Zero pressure testPermanent meter & data logger installationData storage & analysis
A DMA SET-UP
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
5/27
GIS roles in pre-selection of area
GPS Ground Level Survey must be carried out for each feature (hydrant,air valve, pipeline etc) to have a view of terrain on the potential area of
DMA establishment. This information is critical for pressure managementundertaking in the near future.
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
6/27
GIS roles in pre-selection of area
The correct pipeline registration will help define the natural boundary existedby the current supply system- suitable DMA can be planned from this
information. Pipe registration can also be used to identify the measurementof pipeline within the zone as required in the selection criteria.
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
7/27
A typical inlet point to a DMA
Logger abinetLogger abinet trainer
Meter
trainer
Meter
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
8/27
Data Center- H ome of DMAs Data
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
9/27
Netbase W ater Management Software
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
10/27
Daily DMA Monitoring using Netbase
Leakage Leakage
Repair Repair Repair Repair Repair
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
11/27
After a
proper DMA Set-Up
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
12/27
PENISULAR MALAYSIA
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
13/27
SELANGOR
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
14/27
GOMBAK DISTRICT ( Total No of Connections: )
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
15/27
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
16/27
GB100,Kg Dato Keramat (No Of Connections : 1510)
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
17/27
Info of DMA - GB100
Date Established : 30 Sep 2008Mainslength of pipe :12.84 kmNo. of connections : 1510
Pipe materials : AC ( 100
200 dia )
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
18/27
PMI GB100
Permanent Meter Installation (PMI) T he purpose of PMI isto measure incoming flow into the DMA
Level : 36.197 mCoordinate : 1014405.31"E 30954.51"N
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
19/27
PRV GB100
Pressure Reducing Valve (PRV) T he purpose of PRV is toreduce & control the incoming pressure into DMA
Level : 38.255 mCoordinate : 1014405.31"E 30955.28"N
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
20/27
AZP GB100
Average Zone Pressure (AZP) T o measure averagepressure inside DMA
Level : 32.186 m
Coordinate : 10143'25.64"E 30957.18"N
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
21/27
TP GB100
T arget point ( T P) - T he critical (minimum) pressure insideDMA
Level : 32.933 mCoordinate : 1014316.63"E 309'59.23"N
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
22/27
BV 1
BoundaryValve (BV)
DMA GB.100
Outside DMA
Border Of DMA GB.100
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
23/27
BV 2
BoundaryValve (BV)
DMA GB.100
Outside DMA/
District Kuala Lumpur
Border Of DMA GB.100
Border Of District
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
24/27
Boundary Valve (BV)
Boundary Valve
Valve permanently closed to maintainintegrity of DMA
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
25/27
Technological advancement & competition has givenmore equipment choices at lower cost- Battery operated Electromagnetic Flowmeter - GSM/ GPRS Data Logger
- Longer Battery Life
W ide GSM/ GPRS Coverage at low cost for DataPackage (only RM8/ month)
Permanent & Continuous monitoring with GSM DataLogger is cheaper than manual data download in thelong term (savings in manhour and logistic cost)
Current Practices & Technology
-
8/8/2019 DMA Set Up - Jalur Cahaya Sdn Bhd
26/27
Poor mappingDMA breached ( opening of by-pass & BV )Limitation of pressure management
isolated houses & elevationConnectivity issue lack of informationConflict between Operations Dept & NR W units
Supply system changes & road wideningworksShortage of skilled staff
Problem Encountered
-