dlp-s - legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m white 6 380 38 1*...

20
THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES & WIRING DEVICES DLP-S THE MAXIMUM FREEDOM OF CHOICE SNAP-ON AND UNIVERSAL TRUNKING FOR HIGH AND LOW CURRENT DISTRIBUTION

Upload: vuxuyen

Post on 31-Aug-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

THE GLOBAL SPECIALISTIN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

& WIRING DEVICESDLP-STHE MAXIMUMFREEDOM OF CHOICE

SNAP-ON AND UNIVERSAL TRUNKINGFOR HIGH AND LOW CURRENT DISTRIBUTION

EXB15016-EN.indd 1 24/09/15 11:48

Page 2: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

ECO-FRIENDLY• Choice of 100% recyclable materials (PVC)

• Increased requirement: products conformto the RoHS 2 Directive limiting the use of certainharmful substances (lead, mercury, cadmium,hexavalant chromium, PBB and PBDE)

• Recyclable packaging is prioritised

• Selection of our suppliers in accordancewith the REACH regulations

Our production sites are ISO 9001and ISO 14001 certified

Products designedwith the environment

in mind

Legrand is committed toprovide high-quality

products which are suitablefor all your requirements:

The new DLP-S snap-on and universaltrunking fits in perfectly in all buildingsectors, for both new and refurbishmentwork and guarantees the integration ofmultiple ranges of wiring devices.

Be free to chooseyour solution

WWW.LEGRAN

UNIVERSAL TRUNKING:WITH MODULAR OR UNIVERSAL SUPPORTS

Arteor mechanismsmodular supmodules.

Arteor mechon the trunking

SNAP-ONTHE NA

EXB15016-EN.indd 3 24/09/15 11:48

Page 3: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

C)

orme limiting the use of certain

admium,

The flexibilitybefore anything

Legrand offers several dimensionsof DLP-S snap-on or universal trunkingin order to satisfy all installationrequirements and to maximize compatibilitywith the different wiring device ranges, fromArteor to Belanko, Mallia or Synergy.

w DLP-S snap-on and universaly in all building

efurbishmentation of

es.

o choose

1WWW.LEGRAND.COM

THE MAXIMUM FREEDOM OF CHOICEDLP-S

UNIVERSAL TRUNKING: TRADITIONAL INSTALLATION METHODWITH MODULAR OR UNIVERSAL SUPPORTS

Arteor mechanisms can be integrated viamodular supports available from 2 to 6modules.

Arteor mechanisms are simply clippedon the trunking body

Non-modular British standard socket outlets like Synergy, Mallia or Belanko can beinstalled with the help of the universal support.

SNAP-ON TRUNKING:THE NATURAL CHOICE WITH ARTEOR WIRING ACCESSORIES

EXB15016-EN.indd 1 24/09/15 11:48

Page 4: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

SNAP-ON AND UNIVERSALTRUNKING, A RANGESUITABLE FOR MOST OFTHE APPLICATIONS

• 1 single catalogue number per trunking size• Suitable high and low current applications• Can be mounted vertically or horizontally

* For trunking 130 x 50 mm and 190 x 50 mm

An optimised range suitable for the requirements

of any building

Body + cover + partition*

= 1 Single cataloguenumber

2WWW.LEGRAN

* Possible p

SNA

P-O

NU

NIV

ERSA

L

585 x 50

100 x 50

130 x 50

100 x 50

190 x 50

EXB15016-EN.indd 2 24/09/15 11:48

Page 5: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

Cat.NosNumber of

compartmentsLength Colour

6 380 20 1* 2 m White

6 380 30 1* 2 m White

6 380 40 2 2 m White

6 380 38 1* 2 m White

6 380 50 2 2 m White

AND UNIVERSALTRUNKING, A RANGE

FOR MOST OFAPPLICATIONS

ogue number per trunking sizeent applications

y or horizontally

angeements

3WWW.LEGRAND.COM

* Possible partition

50

85 85 x 50

100 x 50

SNA

P-O

NU

NIV

ERSA

L

130 x 50

100 x 50

190 x 50

50

100

50

130

50

100

50

190

5 sizesof trunking

190 x 50

THE MAXIMUM FREEDOM OF CHOICEDLP-S

EXB15016-EN.indd 3 24/09/15 11:48

Page 6: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

Snap-on trunking simple and intuitive installation

• No additional support - simply clip 45 mm Arteor wiringdevices on the trunking body

• Rigid profile with perforations, easy to cut rectangular shape,with protective film during installation

• Self-guiding cover for easy fitting• Sockets held firmly in the trunking

WWW.LEGRAN

1 Rigid rectangular profiles with perforations

244 32 5

2 Self-guiding cover 3 Clip in the Arteor sock

1

4

43

EXB15016-EN.indd 4 24/09/15 11:48

Page 7: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

allationeor wiring

angular shape,

5WWW.LEGRAND.COM

5 5 5

3 Clip in the Arteor socket 4 Fit the Normaclip accessories and45 mm cover

5 Ready to install accessories

5

THE MAXIMUM FREEDOM OF CHOICEDLP-S

EXB15016-EN.indd 5 24/09/15 11:48

Page 8: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

WWW.LEGRAN

6

Universal trunking for the essentials

• Traditional installation method with modular or with universal supports• Compatible with all types of 45 mm mechanism (like Arteor)or with other British standard wiring devices (like Belanko or Mallia)

1 4 52 3

2 Self-guiding cover 3 Really to install accessories 4 Belanko socket and uBritish Standard wiring

1 Rigid profiles with perforations

Can be equipped with modularsupports and Arteor wiringdevices

EXB15016-EN.indd 6 24/09/15 11:48

Page 9: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

7WWW.LEGRAND.COM

THE MAXIMUM FREEDOM OF CHOICEDLP-S

sal supports

3 3 3

5 Arteor sockets and modular supportsories 4 Belanko socket and universal support forBritish Standard wiring devices

EXB15016-EN.indd 7 24/09/15 11:48

Page 10: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

WWW.LEGRAN

8

Ready to install accessories:

save you timeand provide

a perfect finish

VARIABLE ANGLES

A common range of accessoriesfor the snap-on andthe universal trunking*

FIXED VERSION ANGLES

* Except fixed version angles

• Adjust easily to all configurations and provide a perfectfinish for your cable routing (using the variable angles)

• Quick to install, ready to fit assembly, providing an excellent hold

The space-saving solution for sites withoutparticular constraints in termsof configuration

Arteor wiringaccessories

End cap

EXB15016-EN.indd 8 24/09/15 11:48

Page 11: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

9WWW.LEGRAND.COM

THE MAXIMUM FREEDOM OF CHOICEDLP-S

FIXED VERSION ANGLES

es without

Variable version(from 80° to 120°)

Fixed version(90°)

Fixed version(90°)

Cover joint and body jointFlat junction

Variable version(varies from 60° to 120°)

Arteor wiringaccessories

Flat angleEnd cap

INTERNAL ANGLE EXTERNAL ANGLE

EXB15016-EN.indd 9 24/09/15 11:48

Page 12: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

10

DLP-S snap-on trunkingtrunking and accessories

TRUNKING TRUNKING AND ACCESSORIES VARIABLE ANGLES FIXED ANGLES

Number ofcompartments

Cover width(mm)

Cross-section(mm)

Body + cover Partition Body joint Cover joint End cap Internalangle

Externalangle

Internal angle Ext

85 x 50 6 380 20 6 380 08 6 380 26 6 380 00 6 380 25 6 380 21 6 380 22 6 380 27

100 x 50 6 380 30 6 380 08 6 380 36 6 380 00 6 380 35 6 380 31 6 380 32 6 380 17

130 x 50 6 380 40(1) - 6 380 46 2 x 6 380 00 6 380 45 6 380 41 6 380 42 6 380 47

1: Partition(s) supplied with body

80° 120° 60° 120°

100 45

50

130

45

45

50

85 45

50

DLP-S universal trunkingtrunking and accessories

TRUNKING TRUNKING AND ACCESSORIES VARIABLEANGLES

FIXED ANGLESAT 90°

FIXEDANGLES JUNCTION

Number ofcompartments

Coverwidth(mm)

Cross-section(mm)

Body +cover

Partition Body joint Cover joint End cap Internalangle

Externalangle

Internalangle

Externalangle

Flatangle

Flatjunction

100 x 50 6 380 38 6 380 08 6 380 36 6 380 01 6 380 35 6 380 31 6 380 32 6 380 11 6 380 12 6 380 13 6 380 34

190 x 50 6 380 50 6 380 08 6 380 56 6 380 01 6 380 55 6 380 51 6 380 52 - - 6 380 53 6 380 54

100 75

50

190

50

75

75

80° 120° 60° 120°

EXB15016-EN.indd 10 24/09/15 11:48

Page 13: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

11

Arteor wiring accessories

Belanko and Mallia wiring accessories

ARIABLE ANGLES FIXED ANGLES AT 90° JUNCTION

ernalangle

Externalangle

Internal angle External angle Flat angle Flat junction

6 380 21 6 380 22 6 380 27 6 380 28 6 380 29 6 380 24

6 380 31 6 380 32 6 380 17 6 380 18 6 380 19 6 380 34

6 380 41 6 380 42 6 380 47 6 380 48 6 380 49 6 380 44

80° 120° 60° 120°

SOCKETS OUTLETS BRITISH STANDARD

White Red dedicated

2P+E, 13 A2 modules 5 721 11

2 x 2P+E,switched, 13 A3 modules

5 721 30 5 724 67

RJ 45 DATA SOCKETS

UTP FTP STP

Cat. 61 module 5 723 02 5 723 22 5 723 23

Cat. 62 modules 5 723 14 5 723 16 5 723 17

Cat. 5e1 module 5 723 03 5 723 04 -

Cat. 5e2 modules 5 723 15 - -

BRITISH STANDAR SOCKET OUTLETS

White

Belanko Mallia

1-gang 2-gang 1-gang 2-gang

2P+E - 13Aunswitched 6 170 40 6 170 45 2 811 10 2 811 12

2P+E - 13 ASingle pole switched - 13 A 6 171 41 6 171 46 2 811 11 2 811 13

2P+E - 13 ADouble pole switched - 13 A 6 170 43 6 170 48 2 811 16 2 811 17

RJ 45 DATA SOCKETS

White

Belanko Mallia

Single Twin Single Twin

Cat. 5e UTP 6 170 90 - 2 811 61 2 811 64

Cat. 6 UTP 6 171 91 6 170 92 2 811 62 2 811 65

FIXED ANGLESAT 90°

FIXEDANGLES JUNCTION MOUNTING

WIRING ACCESSORIES

Internalangle

Externalangle

Flatangle

Flatjunction

For 45 mm mechanisms Universalfor Britishstandard

wiringaccessories

2 modules 4 modules 6 modules

6 380 11 6 380 12 6 380 13 6 380 34 6 380 02 6 380 03 6 380 04 6 380 05

- - 6 380 53 6 380 54 6 380 02 6 380 03 6 380 04 6 380 05

EXB15016-EN.indd 11 24/09/15 11:48

Page 14: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

12

DLP-S snap-o45 mm cover

DLP-S snap-on trunking 85 x 50 and 100 x 5045 mm cover

Cat.Nos for trunking 85 x 50

Internalvariable angle

Cat.No 6 380 27

Externalvariable angle

Cat.No 6 380 28

Flat junctionCat.No 6 380 24

Flat angleCat.No 6 380 29

Cat.Nos for trunking 100 x 50

Internalvariable angle

Cat.No 6 380 17

Externalvariable angle

Cat.No 6 380 18 Flat junctionCat.No 6 380 34

Flat angleCat.No 6 380 19

Selection chart (p. 10-11)Technical characteristics (p. 16-17)

Selection chart (pTechnical characte

Pack Cat.Nos Snap-on trunking85 x 50 100 x 50 1-compartment trunking

Includes:- 1 body- 1 cover width 45 mmCan take 45 mm wiring accessories,such as Arteor or Mosaic

201 6 380 20 Supplied in 10 unitsof 2 m length

161 6 380 30 Supplied in 8 unitsof 2 m length

Partition32 6 380 08 Separation partition

Length 2 m

Body joint10 6 380 26 6 380 26 For aligning trunking body

during installation

Cover joint10 6 380 00 Cover joint width 45 mm

Pack Cat.Nos Angles85 x 50 100 x 50 Variable angles

10 6 380 21 6 380 31 Internal angle, from 80° to 120°

10 6 380 22 6 380 32 External angle, from 60° to 120°

Fixed angles at 90°16 I 20 6 380 27 6 380 17 Internal angle

8 I 20 6 380 28 6 380 18 External angle

8 I 16 6 380 29 6 380 19 Flat angle

End cap10 I 20 6 380 25 6 380 35 End cap

Flat junction5 6 380 24 6 380 34 Creates a junction between

85 x 50 mm vertical trunkingand any other size of the range

Cat.Nos for trunking 130 x 50

Flat angleCat.No 6 380 49

Pack Cat.Nos 1302-c

121 6 380 40 Inc- 1- 2SupCansuc

Bod10 6 380 46

Cov10 6 380 00

AnglVar

10 6 380 41

10 6 380 42

Fix8 6 380 47

12 6 380 48

8 6 380 49

En10 6 380 45

Fla5 6 380 44

Nor10 6 038 57

85 45

50

100 45

50

1: Number of meters in pack

1: N

EXB15016-EN.indd 12 24/09/15 11:48

Page 15: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

13

DLP-S snap-on trunking 130 x 5045 mm cover

lat junctiont.No 6 380 24

Flat junctionCat.No 6 380 34

Selection chart (p. 10-11)Technical characteristics (p. 16-17)

e, from 80° to 120°

gle, from 60° to 120°

e

ngle

a junction betweenmm vertical trunkingother size of the range

Cat.Nos for trunking 130 x 50Internal

variable angleCat.No 6 380 47

Externalvariable angle

Cat.No 6 380 48Flat angleCat.No 6 380 49

Flat junctionCat.No 6 380 44

Pack Cat.Nos 130 x 50 mm snap-on trunking2-compartment trunking

121 6 380 40 Includes:- 1 body- 2 covers width 45 mmSupplied in 6 units of 2 m lengthCan take 45 mm wiring accessories,such as Arteor or Mosaic

Body joint10 6 380 46 For aligning trunking body during installation

Cover joint10 6 380 00 Cover joint for 45 mm cover

AnglesVariable angles

10 6 380 41 Internal angle from 80° to 120°

10 6 380 42 External angle from 60° to 120°

Fixed angles at 90°8 6 380 47 Internal angle

12 6 380 48 External angle

8 6 380 49 Flat angle at 90°

End cap10 6 380 45 End cap

Flat junction5 6 380 44 Creates a junction between 130 x 50 mm

vertical trunking and any other size of therange

Normaclip accessory10 6 038 57 For 45 mm wiring devices

With anti-pullout and anti-slip systemfor perfect fitting of the mechansims onDLP-S trunking.

130

45

45

50

1: Number of meters in pack

Pack Cat.Nos Aretor British standard socketoutletsShuttered for child safetyASTA licenceConform to BS 1363 Part 2

2P+E - 13 AConform to BS 1363 Part 2; ASTA licence2 modules

10 5 721 11 White

2P+E switched - 13 AConform to BS 1363 Part 2; ASTA licence3 modules

5 5 721 30 White5 5 724 67 Red dedicated non standard pin

Use with plug Cat.No 6 745 32

Arteor RJ45 sockets

With LCS² connector with fast connectionthanks to integrated crimpingTake AWG 22 single-core cables up toAWG 26 and AWG multicore cablesContacts marked with dual colour codeand wiring schemes T568 A and T 568 BConform to standards ISO/IEC 11801 Ed.2.0, amendment 2, EN 50173-1 and TIA/EIA 568 C

Cat 6 Cat 5eUTP

10 5 723 02 5 723 03 1 module

10 5 723 14 5 723 15 2 modules

FTP10 5 723 22 5 723 04 1 module

10 5 723 16 2 modules

STP shielded10 5 723 23 1 module

10 5 723 17 2 modules

EXB15016-EN.indd 13 24/09/15 11:48

Page 16: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

14

DLP-S universal trunking 100 x 5075 mm cover

DLP-S univers75 mm cover

Cat.Nos for trunking 100 x 50

Internalvariable angle

Cat.No 6 380 31

Externalvariable angle

Cat.No 6 380 32Flat junction

Cat.No 6 380 34

Selection chart (p. 10-11)Technical characteristics (p. 16-17)

Selection chart (pTechnical characte

Pack Cat.Nos Universal trunking1-compartment trunking

121 6 380 38 Includes:- 1 body- 1 cover width 75 mmSupplied in 6 units of 2 m lengthCan take :- 45 mm wiring accessories (Arteor or Mosaic)with 75 mm cover support frames (p. 14)- British standard wiring devices(Belanko, Mallia, Synergy) with universal supportCat.No 6 380 05 (p. 15)

Partition321 6 380 08 Separation partition

Length 2 m

Body joint10 6 380 36 For aligning trunking body during installation

Cover joint50 6 380 01 Cover joint for 75 mm cover

AnglesVariable angles

10 6 380 31 Internal angle, from 80° to 120°

10 6 380 32 External angle, from 60° to 120°

Fixed angles at 90°20 6 380 11 Internal angle

20 6 380 12 External angle at 90°

16 6 380 13 Flat angle at 90°

Pack Cat.Nos Uni1-c

81 6 380 50 Inc- 1- 1SupCan- 45or Mfram- Br(BeCat

Par321 6 380 08

Bod10 6 380 56

Cov50 6 380 01

Angl10 6 380 51

10 6 380 52

5 6 380 53

En10 6 380 55

Fla5 6 380 54

Pack Cat.Nos End cap20 6 380 35 End cap

Flat junction5 6 380 34 Creates a junction between 100 x 50 mm

vertical trunking and any other size ofthe range

1: N

1: Number of meters in pack

100 75

50

Cat.Nos for trunking 190 x 50

EXB15016-EN.indd 14 24/09/15 11:48

Page 17: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

15

DLP-S universal trunking 190 x 5075 mm cover

Flat junctionCat.No 6 380 34

Selection chart (p. 10-11)Technical characteristics (p. 16-17)

Pack Cat.Nos Universal trunking1-compartment trunking

81 6 380 50 Includes:- 1 body- 1 cover width 75 mmSupplied in 4 units of 2 m lengthCan take :- 45 mm wiring accessories (Arteoror Mosaic) with 75 mm cover supportframes (p. 14)- British standard wiring devices(Belanko, Mallia, Synergy) with universal supportCat.No 6 380 05 (p. 15)

Partition321 6 380 08 Separation partition

Length 2 m

Body joint10 6 380 56 For aligning trunking body during installation

Cover joint50 6 380 01 Cover joint for 75 mm cover

Angles10 6 380 51 Internal angle from 80° to 120°

10 6 380 52 External angle from 60° to 120°

5 6 380 53 Flat angle at 90°

End cap10 6 380 55 End cap

Flat junction5 6 380 54 Creates a junction between 100 x 50 mm

vertical trunking and any other size of therange

Pack Cat.Nos Supports for 45 mm wiring devicesFor mounting Arteor wiring accessoriesClip-on suports, which can be fitted side by sideSupplied with white finishing plateFor cover 75 mm width

10 6 380 02 For 2 modules

5 6 380 03 For 4 modules

5 6 380 04 For 6 modules

Universal support5 6 380 05 British standard wiring devices

such as Belanko, Mallia or Synergy rangesFor cover 75 mm width

n between 100 x 50 mmand any other size of

1: Number of meters in pack

Cat.Nos for trunking 190 x 50

Internalvariable angle

Cat.No 6 380 51

Externalvariable angle

Cat.No 6 380 52

Flat junctionCat.No 6 380 54

190

50

75

75

RJ 45 socket outletsp. 11

British standard socket outletsp. 11

EXB15016-EN.indd 15 24/09/15 11:48

Page 18: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

16

DLP-S snap-on and universal trunking

n Technical characteristics

• Resistance to impact for installation and application: 2.0J• Minimum storage and transport temperature: - 25 °C• Minimum installation and usage temperature: - 5 °C• Maximum application temperature: + 60 °C• Resistance to flame propagation: Non-flame propagating• Without electrical continuity characteristic• With electrical insulating characteristic• Degrees of protection: IP 40• Rated current: 500 V• Against mechanical shocks: IK 07

n Wiring capacity

Snap-on trunking

Universal trunking

Dimensions Cross-section percomp. (mm2) Capacity

Max. number of conductors (of the same type)Cable Ø max. (mm)

3 x 1.5 mm2 3 x 2.5 mm2 UTP & FTP cat. 6 (mm)

85 x 50Cat.No 6 380 20

85 45

50

1

2940 Max. 26 19 58

362092 With 2P+E socket 18 13 41

2618 With RJ 45 socket 23 17 52

100 x 50Cat.No 6 380 30

100 45

50

1

4146 Max. 36 27 82

362738 With 2P+E socket 24 17 54

3264 With RJ 45 socket 29 21 65

130 x 50Cat.No 6 380 40

130

45

45

50

1

2646 Max. 23 17 52

36

1256 With 2P+E socket 11 8 25

1762 With RJ 45 socket 15 11 35

2

2616 Max. 23 17 52

1206 With 2P+E socket 10 7 24

1732 With RJ 45 socket 15 11 34

Dimensions Cross-section percomp. (mm2) Capacity

Max. number of conductors (of the same type)Cable Ø max. (mm)

3 x 1.5 mm2 3 x 2.5 mm2 UTP & FTP cat. 6 (mm)

100 x 50Cat.No 6 380 38

100 75

50

1 4224 Max. 47 33 172 40

190 x 50Cat.No 6 380 50

1

4017 Max. 45 29 164 40

2

Variable internal angle

Variable external angle

Flat angle

n Example of installa

n Installation principle for Normaclip accessory

Put the Normaclipaccessory in placewithout completelyclipping it on thetrunking body

1 2

Slide it next to the socketoutlet and fix thetrunking covers

3

Push the Normaclipaccessory in order to clipit on the trunking bodyand secure the system

4

190

50

75

75

EXB15016-EN.indd 16 24/09/15 11:48

Page 19: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

Cable Ø max. (mm)m)

36

36

36

Cable Ø max. (mm)m)

40

40

Variable internal angle

Variable external angle

Flat angle

End cap

Flat junction

Body joint

For DLP-S 100 x 50 universal trunkinguse the special adaptor

For DLP-S 100 x 50 universal trunkinguse the special adaptor

1. Install the base of the flat angle andthe two sections of trunking

2. Clip-on the cover of the flat angleTake care of having a minimumdistance between the trunking andthe adjacent wall, in order to allow theinstallation of the angle

For a perfect finish and a better shockresistance block the end cap with thetwo fixing screws (provided)

The flat junction can be used for anysize of DLP-S trunking, in horizontalposition

1. Install the body joint support(between two sections of trunking)

2. Clip-on the body joint cover

n Example of installation

EXB15016-EN.indd 17 24/09/15 11:48

Page 20: DLP-S - Legrand · y in all building efurbishment ation of es. ... 6 380 40 2 2 m White 6 380 38 1* 2 m White ... t.No 6 380 24 Flat junction

Head office128, av. du Maréchal-de-Lattre-de-Tassigny87045 Limoges Cedex - France% : + 33 5 55 06 87 87Fax : + 33 5 55 06 74 55

www.legrand.com

www.youtube.com/user/legrand

twitter.com/legrand_news

FOLLOW USALSO ON

EXB

1501

6 -

Sept

embe

r20

15-

Pho

tos:

Get

ty-

Thin

ksto

ck

EXB15016-EN.indd 18 24/09/15 11:48