dl2000 - torospecifier.toro.com/cads/drip/dl2000/center_layout/065-188g.pdftoro dl2000...

1
DL2000 CENTER-FEED LAYOUT 065-188g ® AV FV FV www.CADdetails.co www.toro.com TORO-IRRIGATION DIVISION 5825 JASMINE STREET RIVERSIDE, CA 92504 TOLL FREE: 1-877-345-8676 FAX: (951) 359-1870 [email protected] PROTECTED BY COPYRIGHT ©2014 CADDETAILS.COM LTD. REVISION DATE 03/21/2017 4 3 2 1 7 6 5 8 9 10 11 12 1 2 TORO DL2000 AUTOMATIC FLUSH VALVE (FCH-H-FIPT) PLUMBED TO FLUSH MANIFOLD AT LOW POINT. PVC FLUSH MANIFOLD. TORO DL2000 MANIFOLD-TO-ELBOW CONNECTION (TYP). PVC LATERAL LINE FROM DRIP ZONE KIT. PVC SUPPLY MANIFOLD. TORO DL2000 MANIFOLD-TO-TEE CONNECTION. TORO DL2000 DRIPLINE LATERAL (RGP-XXX-XX). AIR/VACUUM RELIEF LATERAL, TORO BLUE STRIPE POLY TUBING (T-EHD1645-XXX) CENTERED ON MOUND OR BERM. TORO DL2000 AIR/VACUUM RELIEF VALVE (YD-500-34) PLUMBED TO TORO BLUE STRIPE POLY TUBING (T-EHD1645-XXX) AT EACH HIGH POINT. PERIMETER LATERALS 2" TO 4" FROM EDGE. AREA PERIMETER. TORO DL2000 OPERATION INDICATOR (T-DL-MP9), OPTIONAL. 7 6 5 4 3 2 1 9 8 10 11 12 NOT TO SCALE PLAN LEGEND: NOTES: 1. THE TOTAL LENGTH OF ALL INTERCONNECTED DRIP LINE SHALL NOT EXCEED THE MAXIMUM RUN LENGTH. SEE TORO SUBSURFACE IRRIGATION DESIGN GUIDE (FORM #ALT111). 2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 3. DO NOT SCALE DRAWING. 4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION. 5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE. 6. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER REFERENCE NUMBER 065-188g.

Upload: others

Post on 07-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • DL2000CENTER-FEED LAYOUT

    065-188g

    ®

    AV

    FV

    FV

    www.CADdetails.com

    www.toro.com

    TORO-IRRIGATION DIVISION5825 JASMINE STREETRIVERSIDE, CA 92504TOLL FREE: 1-877-345-8676FAX: (951) [email protected]

    PROTECTED BY COPYRIGHT ©2014 CADDETAILS.COM LTD.

    REVISION DATE 03/21/2017

    4

    3

    2

    1

    7

    6

    5

    8

    9

    10

    11

    121 2

    TORO DL2000 AUTOMATIC FLUSHVALVE (FCH-H-FIPT) PLUMBED TOFLUSH MANIFOLD AT LOW POINT.

    PVC FLUSH MANIFOLD.

    TORO DL2000 MANIFOLD-TO-ELBOWCONNECTION (TYP).

    PVC LATERAL LINE FROM DRIP ZONEKIT.

    PVC SUPPLY MANIFOLD.

    TORO DL2000 MANIFOLD-TO-TEECONNECTION.

    TORO DL2000 DRIPLINE LATERAL(RGP-XXX-XX).

    AIR/VACUUM RELIEF LATERAL, TOROBLUE STRIPE POLY TUBING(T-EHD1645-XXX) CENTERED ONMOUND OR BERM.

    TORO DL2000 AIR/VACUUM RELIEFVALVE (YD-500-34) PLUMBED TO TOROBLUE STRIPE POLY TUBING(T-EHD1645-XXX) AT EACH HIGH POINT.

    PERIMETER LATERALS 2" TO 4" FROMEDGE.

    AREA PERIMETER.

    TORO DL2000 OPERATION INDICATOR(T-DL-MP9), OPTIONAL.

    7

    6

    5

    4

    3

    2

    1

    9

    8

    10

    11

    12

    NOT TO SCALE

    PLAN

    LEGEND:

    NOTES:1. THE TOTAL LENGTH OF ALL INTERCONNECTED DRIP LINE SHALL NOT EXCEED THE MAXIMUM RUN LENGTH. SEE TORO SUBSURFACE IRRIGATION DESIGN GUIDE (FORM #ALT111).2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.3. DO NOT SCALE DRAWING.4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN

    PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND

    APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.6. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

    REFERENCE NUMBER 065-188g.