ditel gsm - 4 door - digitalas · ditel - gsm 4 door - gsm is an ... supply voltage 11-14v dc....

16
1 GSM DiTeL control module - GSM 4 Door USER MANUAL

Upload: vantuyen

Post on 20-Jun-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

1

GSM DiTeL control module- GSM 4 Door

USERMANUAL

Page 2: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

2

USER MANUAL

GSM DiTeL control module - GSM 4 Door

CONTENTS1. GENERAL DESCRIPTION..................................................................................................................22. SPECIFICATIONS................................................................................................................................33. CONNECTIONS (GETTING STARTED)............................................................................................44. PROGRAMMING AND SETUP...........................................................................................................5

4.1. File“admin”....................................................................................................................................54.2. File“phone1”and ”phone2”............................................................................................................64.3. File“phoneM“.................................................................................................................................64.4. File“pass”.......................................................................................................................................7 4.5. File“call”........................................................................................................................................7 4.6. File“time”......................................................................................................................................7 4.7.File ”volume”.................................................................................................................................8 4.8.file „temp“......................................................................................................................................8

5. REMOTE CONTROL. COMMANDS..................................................................................................8 5.1. SMS command ADD ...................................................................................................................8 5.2. SMS command DEL ....................................................................................................................9 5.3. SMS command INF......................................................................................................................9 5.4. SMS command MIC......................................................................................................................9 ............................................................................................................................................................105.5. SMS command SPK.....................................................................................................................10 5.6. OUT1 output control via a telephone call to the module number...............................................10 5.7. OUT1 output control via a telephone call to the module............................................................10 5.8. OUT2 output management by sending an SMS..........................................................................10 5.9. OUT2 output control via a telephone call to the module............................................................10

6. EQUIPMENT AND WARRANTY......................................................................................................11

1. GENERAL DESCRIPTION

GSM DiTeL control module - GSM 4 Door - the latest development of JSC DIGITALas,which combines the functions of a GSM DiTeL modules - GSM Apartment and DiTeL - GSM Gate.GSM DITEL control module - GSM 4 Door (hereinafter - DITEL - GSM module or 4 Door) - one ofthe GSM line modules DITEL GSM remote control, the award-winning "Innovation of the Year 2015"in the field of technological solutions.

DiTeL - GSM 4 Door - GSM is an electronic controller (remotecontrol unit intercom and automatic gate), which is designed for re-mote control intercom, automatic gates and wickets cottages, privatehomes, small apartment buildings, as well as barriers to the protectedareas. You can also control the lock entrance door and talk to the in-coming through the internal intercom system being far from homeand with nothing but a mobile (cell) phone. The module operates on aGSM network, so the control module you can use any mobile (cell)

Page 3: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

3

phone.

The principle of operation of the device

In DiTeL memory - GSM 4 Door prescribed numbers (database), from which the call, the lockopens (closes), and when you click on the outside panel room apartment unit will make a phone call tothe specified phone number. When the device receives a phone call, the incoming call telephone num-ber to compare with the existing database. If the phone number is in the database - DiTeL - GSM 4Door rejects the call (connection) and opens (closes) the castle.

By clicking on the entry panel DiTeL room apartment - GSM 4 Door makes a telephone callfrom the memory number 1 (Phone1 base) (see section 4.2...). If the subscriber is busy or does not re-spond within the specified time, the dials of the memory 2 (phone2 base) (see. P. 4.2.). If a successfulconnection is made voice. Opening the door lock when you press the # key on the phone, and for OUT2(auxiliary output, can be used for automatic gates) - * key.

Advantages

1. It is safe. No one can clone your phone number as easy as the standard code for the remote con-trol

2. Easy to operate. It is easy to add new users, delete users, or change the settings by editing the"text" file on the microSD memory card or via SMS

3. Comfortable. Your mobile phone is always with you, at the time when the remote control willnot be at hand, or is not available.

Capabilities

• the ability to talk to the incoming through the communication device using the mobile phone,only to listen to what is happening at the intercom or just talking on the intercom (one-waycommunication)

• outputs control via phone call and (or) SMS messages• set of subscriber numbers from the corresponding type on the keyboard. Each of the two data-

bases can contain up to 4 numbers (4 buttons ringer) + 95 rooms for an automatic gate (outputcontrol relay switching)

• 4 inputs to control intercom (1-4 user)• time configuration trigger outputs (0 to 999 sec. or monostable position)• latency answer phone control• control levels of conversational signals• opportunity to room database management through SMS• module configuration settings can be made (done) by configuration "text" files stored on the mi-

croSD memory card

2. SPECIFICATIONS

• dimensions: 65 * 40 * 25 mm• Power Voltage: 12-14V DC, the use of a backup battery 12B• current consumption: up to 70mA (standby) to 150mA (operation), the source should provide a

short-term peak current up to 3 A• Support 4 Frequency: GSM 850/900/1800/1900 MHz

Page 4: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

4

• number of inputs: 4 pcs. (For ringer buttons)• Number of outputs: 2 pcs. (Open collector output and relay changeover)• Open collector output : 1 pc., is controlled by sending SMS• Output relay switching:. 1pc, controlled phone calls• the number dialed numbers: two bases for 4 + 95 numbers for automatic gates• Display: 2 LEDs• antenna connection (connector type): SMA• User Memory: microSD (up to 16 Gb)• one-way communication: yes

3. CONNECTIONS (GETTING STARTED)

Insert the SIM card with a PIN code previously disconnected the device. Guided by this manual(see. Section 4), change the settings in the configuration files located on the attached microSD memorycard. Insert the microSD card into the device. Observing polarity, connect the antenna to the board, ex-ternal input / output devices and power supply, as shown in Figure 1. After that, apply power to themodule.

Fig.1

Designation Appointment

Outdoor unit External ringing - intercom

GSM ant GSM antenna with SMA connector

SIM GSM SIM card with pre disabled PIN, 4 frequency GSM 850/900/1800/1900 MHz. network opera-tors should be supported by broadcast time

MicroSD Up to 16 GB, a pre-formatted in the FAT32 file system

LEVEL Control the volume level

1, 2, 3, 4 Contact connection ringer buttons

BAT backup power supply (12V battery)

GND Main contact

+12V Main (mains). Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). The source should provide a short-term peak current up to 3 A. When a power outage at thiscontact (if a back-up battery), the module will automatically send an SMS message "AC error", after avoltage - "AC OK". SMS sent to the number specified in the admin (see. Table Nr.1)

IN1, IN2 Input 1, Input 2 Not used

Attention! Connecting cards with the power supply can cause damage to the device!

Page 5: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

5

GND Main contact

OUT2 Open collector output for connecting external devices. 100mA, 12V, controlled by sending SMS(see. Table Nr.2)

GND Main contact

OUT1 The output relay switch controlled telephone calls (see. Table Nr.2)

NC Contact relay output OUT1: normally closed

C Contact relay output OUT1: main

NO Contact relay output OUT1: normally open

After power briefly lights up red LED "STATUS", after about 3 seconds the module will checkthe memory card. In case of an error (fault or absence of the card in the slot), the red LED will start toblink constantly. In case of successful test, after about 10-20 seconds after the successful registration inthe network, the module will signal solid green LED. Then, the red LED will blink three times. Afteranother 20 seconds, if the GSM signal level exceeds 30%, the red LED signal lights steadily. The mod-ule automatically synchronizes the time over the GSM network and is ready for operation.

4. PROGRAMMING AND SETUP

(Table Nr.1)

Module configuration is managed through "text" files placed on a pre-formatted in FAT32 mi-croSD memory card file system.

The file structure on the card microSD memory is as follows (see Table Nr.1.): A folder (direc-tory, directory), the LOG (not used) and SET folder. The SET posted the directory configuration files:admin, call, pass, phone1, phone2, phoneM, time, volume, temp.

All configuration files required format originally created on the memory card with the default set-tings.

4.1. File“admin”

A password (a password) through which access to the management database of phone numbersphone1 and phone2 (see. P. 4.2.) Through SMS. Access to the control module via SMS (see. TableNr.2) carried out a phone number to register in this database "admin.txt". Database format:

– five characters - any letters (large and small) of the Latin al-phabet and numbers

– separator "semicolon"– the phone number in international format

Important! 2. 1. While editing, creating, and restoring the database, make sure that the configuration file nameextension,, text "Document - ,, TXT", a file name matches exactly with the name spelled out in thisdocument (including letter case).3. 2. All records (rows) in the configuration files should be made strictly following the data entryformat prescribed in this manual and the official end newline sign - ,, ENTER ".4. 3. Configuration files must be in the SET folder.

Example entries:admin;+372454899988

Record sensitive.

ATTENTION! Password is the password supervisor, allowing to carry out the service SMS servicemodule. The telephone number registered in the base admin password is not a user ID and input (out-put) module does not control. The default password - ,, admin "

IMPORTANT! The passwords in the databases managed by SMS messages (admin and pass)must be different!

Page 6: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

6

4.2. File“phone1”and ”phone2”

Base phone numbers that are written phone numbers corresponding to thekeys typing, as well as phone numbers of control output OUT1 via a tele-phone call to the module number. Each of the two databases can contain up to4 telephone numbers to ringer buttons (intercom) + 95 rooms for managingthe OUT1 output (used for door lock) by means of a phone call to the numberof the device. Phone numbers used for intercom (4 in each database) canmanage two outputs (OUT1 and OUT2) (see. Pp 5.6.-5.9., And Figure 1). Total in databases can bemade for 2 rooms on each of the 4 buttons intercom + 190 room door lock (OUT1) (see. P. 5.6. Controloutput OUT1 via a telephone call to the module number).

To create a database of phone numbers, create a file (if not created) text files «phone1.txt» and«phone2.txt». database format is a string with the following parameters:

– the serial number of the record (001-099)– separation sign "colon"– the phone number in international format

4.3. File“phoneM“

The database of phone numbers. Management microphone and speakerintercom (one-way communication or two-way communication) is carried outby means of a telephone call with the introduction to this database number (upto ten numbers). The base is dependent on the single permit, including (activat-ing function). By sending an SMS "password; MIC» to the device (. Nr.1 see ta-ble) is activated one-way communication. By sending an SMS "password; SPK»to the device (. Nr.1 see table) activated two-way communication.

to create a text file «phoneM.txt» To create a database file. database format is a string with thefollowing parameters:

- Identifier "semicolon"– Phone number in international format

Example entries:001:+37055512354002:+37166655589059:+95022233333

If the base there is only one line, "+", then the control is carried out with any number, make a callto the module.

Example entries:;+37055511111;+37312312345

1.The number of entries in each of the databases 001 to 099.The sequence number of the record (cell) must be submitted in the form of a three-digit, respec-

tively, with one or two insignificant zeros.2. Serial numbers of entries (cells) 001 to 004 are used for the 4 buttons ringer (full control of out-

puts OUT1 and OUT2 (see. 5.6.-5.9 percentage points.)). If involved fewer ringer buttons, the corre-sponding cells are not involved, phone numbers will not control module outputs via a telephone callto the phone number (see. 5.7 pp. And 5.9.).

3. Serial number entry (cell) from 005 to 099 are used to record phone numbers of control outputOUT1 via a telephone call to the module number.

Page 7: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

7

4.4. File“pass”

A password with which to access to management of the second output OUT2. For OUT2 controlany number should be sent to the number SMS message subscriber unit (see. Table Nr.2), consisting offive characters for the password registered in "pass.txt". Control output OUT2 is nomeronezavisimym,carried out from any phone number, send an SMS with the password assigned in the database. outputresponse time when the right password is set in the base time (see section4.6...) the database format:

– serial access code number (01-10)– separation sign "colon"– five characters - any letters (large and small) of the Latin alphabet and

numbers.

4.5. File“call”

Base settings timeout call is answered. In this basis, prescribed time (in seconds from 5 to 30 s)during which the module will wait for a response from the subscriber is registered in the base Phone1(see. 4.2.). At the expiration of the set time, the unit will produce a set of numbers from phone2 base.

Create (if not created) a text file «call.txt» To create a base configura-tion file timeout response subscriber. database format is a string with the fol-lowing parameters:

two digits (waiting time, in seconds from 5 to 30)

4.6. File“time”

setting time base supply voltage to external de-vices OUT1 and OUT2 (see. table Nr.1). In a phonecall to the module (for OUT1) or SMS (for OUT2), aswell as, at the end of a call from the module, on themobile phone by pressing the # (for OUT1 - doorlock) or * (for output OUT2 - automatic gate), will voltage supplied to the corresponding output timeset on the file.

Is controlled by entry in the «time.txt» data. Recording format:

Example entries:01: 005 (duration of the operation keywith the right number of the caller)02: 000 (key opens when incoming SMSand closes when re-SMS)

If the value is up to 10 seconds, then it must be present in the form of a two-digit one insignificantzero (eg 05 or 09)

IMPORTANT! Duration (time) a call (connection) with the limited party software. Installed maxi-mum call duration is 59 seconds. This time setting can not be changed by the user. After 59 sec. com-munication module (intercom) with the subscriber (telephone number is registered in the basephone1 or phone2 (see. 4.2.)) will automatically end.

IMPORTANT! The passwords in the databases managed by SMS messages (admin and pass) mustbe DIFFERENT!

Example entries:01:1234502:Aa25603:aaaa104:AaAaA

1. Record sensitive.2. The number of entries from 01 to 10.Serial number access code must be present in two-digit form, respectively, the numbers 1 - 9, with

one in two insignificant zero (eg 05 or 09).3. The number of control rooms is not limited.

Example entries:15

Page 8: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

8

– the serial number of the output 01 or 02 (01 telephone set, 02 SMS)– separation sign "colon"– three numbers - time voltage outputting in seconds from 1 to 999.

4.7.File ”volume”

Base level settings conversational signals. In this basis, the relative values of prescribed levelsof loudness microphone intercom and intercom speaker.

Create (if not created) a text file «volume.txt» To create a base config-uration file timeout response subscriber. The format database consists of tworows with the following parameters:

– first line: two digits (intercom microphone level from 10 to 99)– second row: two digits (intercom speaker level from 01 to 15)

4.8.file „temp“

Temporary data base. Entries in the base system (module) is automatically created. Users to editentries in this database is not required.

5. REMOTE CONTROL. COMMANDS.

(Table Nr.2)

5.1. SMS command ADD

ADD command adds the numbers in a database of phone numbers phone1 (base A) and phone2(base B) (see. Table Nr.1). Rooms are added one by one. To add to the database of phone numbers thenew managing phone number is required with the phone number is registered in the base admin (see. §4.1.), Send SMS to the unit number set format. The format is sent to the SMS module is a string withthe data:

- password registered in the base admin (see. p. 4.1.)- Separator "semicolon"- ADD command

The value of 000 translates corresponding output in the bistable condition that causes the key actua-tion (opening and closing) for each event, ie, opening and closing when receiving a call or SMS.

Time must be submitted in the form of a three-digit, respectively, with one or two insignificant ze-ros (eg 005)

Example entries:2509

If the value is up to 10 units, it must be present in the form of a two-digit one insignificant zero(eg 05 or 09)

Important! Write commands are case sensitive. For correct operation of SMS commands must beenabled in receiving an SMS notification only in Latin letters.

Important! The signal level is also installed with the help of the sound volume control on the mod-ule (see. Fig. 1).

Example entries:admin;ADD;099B+37155566667admin;ADD;001А+37155566668

Page 9: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

9

- Separator "semicolon"- Serial number of the record (001-099) (see section 4.2...)- Base code (A - for phone1 or B - for phone2) which produced a record- Phone number in international format.- After the command module sends an SMS about the operation produced.

5.2. SMS command DEL

DEL command removes the number from the database phone1 (base A)and phone2 (base B) (see. Table Nr.1). Rooms are removed one by one. The for-mat is sent to the SMS module is a row with data similar to the ADD command(see. P. 5.1.), Without prescribing the phone number in the deleted record (cell).After the command module sends an SMS about the operation produced.

5.3. SMS command INF

command INF request information inscribed in the memory (base phone1 telephone numbers(Index A) and phone2 (index B )) (see. Table Nr.1) telephone network control room. The format is sentto the SMS module is a string with the data:

– password registered in the base admin (see. p. 4.1.)– separator "semicolon"– INF command– separator "semicolon"– the serial number of the record (001-099) (see. p. 4.2.)– the index of the requested base (A - for phone1 or B - for phone2)In response, the module to the phone number of the admin database will send an SMS message

to the phone number corresponding to the serial number entry (cell) (001-099) in the two databases (In-dex A - for phone1 and the index B - for phone2) (see section 4.2.. .), as well as information about thelevel of GSM signal.

5.4. SMS command MIC

MIC command allows a one-time switch (activates) the intercom.Sent SMS to any number in the subscriber number of the device, activatesthe microphone function.

In response, the module will send a message «Mic temporary ON" -the function is active, have registered a phone number in the database admin (see Table 1).. After acti-vating the function, calling the device phoneM made to the base (see. Table 1) a telephone number,you can listen to what is happening in the device. After completing the call the device returns to its ini-tial state.

5.5. SMS command SPK

Command SPK allows a one-time switch (activates) the intercom.Sent SMS to any number in the subscriber number of the device, activatethe intercom function.

In response, the module will send a message «Mic temporary ON" - the function is active,

Example entries:admin;MIC

Important! When adding phone numbers, make sure that the recording made by a serial number(the corresponding cell) is not occupied by another phone number. To do this, use the INF command(see. P. 5.3.)

Example entries:admin;DEL;020А

Example entries:admin;INF;113A

Example entries:admin;SPK

Page 10: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

10

have registered a phone number in the database admin (see Table 1).. After activating the function bycalling the phone number of the device with a structure belonging to phoneM base (see. Table 1) tele-phone number, intercom system will work in two-way voice communication mode (reception-transmis-sion), and you can contact (talk) with a man at the intercom. After completing the call the device re-turns to its initial state.

5.6. OUT1 output control via a telephone call to the module number

Manufactured call any of the phone numbers registered in databases of phone numbersphone1 and phone2) (see. P. 4.2.) Triggers the output relay switching OUT1 (see. Fig. 1) at the timeprescribed in the database time (see. Table Nr.1 )

5.7. OUT1 output control via a telephone call to the module

By clicking on the entry panel room apartment module generates a telephone call numbers(Phone1 base, the corresponding cell (index number 001-004) (see. P. 4.2.)). If the subscriber is busy ordoes not respond within the time set in the time-based call setup (see. Nr.1 table), the dials of the corre-sponding cell phone2 base (see. P. 4.2.). If a successful connection is made voice. And when you pressthe # key on the phone triggers the output relay switching OUT1 (see. Fig. 1) at the time prescribed inthe database time (see. Table Nr.1).

5.8. OUT2 output management by sending an SMS

OUT2 output management by sending an SMS from any phone number. Output Activation isinitiated by sending an SMS with a password, spelled out in the database pass passwords (see. TableNr.1), sent to the module number from any phone number. The module receiving the correct password,the OK output for connecting external devices (OUT2) will give a constant current 100mA, 12V (see.Figure 1)

5.9. OUT2 output control via a telephone call to the module

By clicking on the entry panel room apartment module generates a telephone call numbers(Phone1 base, the corresponding cell (index number 001-004) (see. P. 4.2.)). If the subscriber is busy ordoes not respond within the time set in the time-based call setup (see. Nr.1 table), the dials of the corre-sponding cell phone2 base (see. P. 4.2.). If a successful connection is made voice. And when you pressthe * key on the phone initiates operation of OUT2 output (see. Fig. 1) at the time prescribed in thedatabase time (see. Table Nr.1).

6. EQUIPMENT AND WARRANTY

Packaging unit: GSM DiTeL control module - GSM 4 Door, GSM antenna, microSD memorycard (4GB), ringer (SAC5), power supply (1,5 A, 12 V)

GSM DiTeL control module - GSM 4 Door is the product of CJSC DIGITALas®

JSC DIGITALas this product provides a guarantee for 24 months.

Attention! When using the unit for other purposes, as well as non-compliance with this in-struction manual, warranty does not cover.

Page 11: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

Table Nr.1 System Configuration. Configuration files.

The fileon the

memorycard

Format Appointment record format Example entries Note

SET folder The main folder for configuration files (settings) admin, call,pass, phone1, phone2, phoneM, time, volume, temp

Pre-create a folder in the root directory SET All configuration files previously createdin the "text" file format (.txt extension)

LOG folder Folder for storing logs (history) event Pre-create a folder in the root directory LOG Not used

admin file inTXTformat.Apassword

A password (a password) through which access to the devicemanagement via SMS.IMPORTANT! The passwords in the databases managed bySMS messages (admin and pass) must be DIFFERENT!

- Five characters - any letters (largeand small) of the Latin alphabet andnumbers (default - ,, admin")- Separator "semicolon"- Phone number in international format

admin;+37245489998

Password is the passwordsupervisor, allowing to carry out theservice SMS service module.Record sensitive.

phone1 file inTXTformat.Basephonenumbers

First base of telephone numbers which are written phonenumbers corresponding to the keys typing (phone numbersdialed first when you press the intercom button), as well asphone numbers of control output OUT1 via a telephone callto the module number.The database can contain up to 4 telephone numbers to ringerbuttons (intercom) + 95 rooms for managing the OUT1output (used for door lock) by means of a phone call to thenumber of the device.

- Serial number of the record (001-099)- Separating sign "colon"- Phone number in international format

001:+37055512354002:+37166655589059:+95022233333

Number of records from 001 to 099. Thesequence number of the record (cell)must be submitted in the form of a three-digit, respectively, with one or twoinsignificant zeros.Phone numbers used for intercom (4buttons, recording serial numbers (cell)from 001 to 004) can control bothoutputs (OUT1 and OUT2) (see. Pp 5.6.-5.9.)Serial numbers of entries (cells) from005 to 099 are used to record phonenumbers of control output OUT1 via atelephone call to the module number.(See para. 4.2 pp. And 5.6.)

phone2 file inTXTformat.Basephonenumbers

Second base of telephone numbers which are written phonenumbers corresponding to the keys typing (phone numbersdialed by pressing the intercom module if the subscriberdoes not answer phone1 of a button), as well as phonenumbers of control output OUT1 via a telephone call to themodule number.Features and purpose: see the information on the basis ofphone1.

view information based phone1 view informationbased phone1

view information based phone1

Page 12: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

phoneM file inTXTformat.Basephonenumbers

The database of phone numbers to control an externalintercom system via a phone call.Control is activated by a single permit - SMS (see MIC team,SPK, Table 2.) Sent from any number. The telephone numberregistered in the base admin receives an activation function.After a one-time activation by calling the device made to thebase of the phone number, you will hear what is happening inthe device (one-way communication) or, respectively,activating the microphone and loudspeaker of the externalintercom (team SPK) - two-way communication.

- Identifier "semicolon"- Phone number in international format

;+95022233333 The record length is limited to tennumbers.If there is a row in the database, "+",then the control (listen what ishappening) is possible with anynumber, make a call to the module.Activating the intercom number isindependent.

pass file inTXTformat.Apassword

A password with which to access to management of thesecond output OUT2.For OUT2 control any number should be sent to the devicephone number SMS message consisting of five characters forthe password.IMPORTANT! The passwords in the databases managed bySMS messages (admin and pass) must be DIFFERENT!

- Serial access code number (01-10)- Separating sign "colon"- Five characters - any letters (largeand small) of the Latin alphabet andnumbers

01:1234502:1111103:5555504:ABCDE05:AaAaA06:KKKK1

Record sensitive.Number of records from 1 to 10.The number of control numbers is notlimited.

call file inTXTformat.Basetimesettings

Base settings timeout call is answered. In this basis,prescribed time (in seconds from 5 to 30 s) during which themodule will wait for a response from the subscriber isregistered in the base Phone1 (see. 4.2.). At the expiration ofthe set time, the unit will produce a set of numbers fromphone2 base.

- Two digits (waiting time, inseconds from 5 to 30)

15 If the value is up to 10 seconds,then it must be present in the formof a two-digit one insignificantzero (eg 05 or 09)

time file inTXTformat.Base timesettings

time voltage supply control external devices OUT1 andOUT2. When the phone call (for OUT1) or SMS (for OUT2),as well as through the * or # keys on the mobile phonekeyboard (during communication) will be supplied to theappropriate output for the time set in this file. The phonenumbers are registered in the control OUT1 bases, phone1phone2 (see. 4.2 pp., 5.6., 5.7.), Is not limited (see. Pass) forOUT2 number of control numbers.

- Serial number of the OUT output - 01or 02 (OUT1: 01- telephone set, OUT2:02- SMS)-razdelitelny sign "colon"- Three numbers - time voltageoutputting in seconds from 1 to 999 *

01: 005(Key responsetime with theright number ofthe caller)02: 000(The key willopen when theincoming SMSand will beclosed when re-SMS)

Time must be submitted in the formof a three-digit, respectively, withone or two insignificant zeros (eg005)The value of 000 translatescorresponding output in the bistablecondition that causes the keyactuation (opening and closing) foreach event: receiving a call or SMS.

Page 13: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

volume file inTXTformat.

Base level settings conversational signals. In this basis, therelative values of prescribed levels of loudness microphoneintercom and intercom speaker.Important! The signal level is also installed with the help ofthe sound volume control on the module (see. Fig. 1).

- First line: two digits (intercommicrophone level from 10 to 99)- Second line: two digits (intercomspeaker level from 01 to 15)

25 (first line)09 (second line)

If the value is up to 10 units, itmust be present in the form of atwo-digit one insignificant zero(eg 05 or 09)

temp TimeDataBase

Temporary data base. Users to edit entries in this database isnot required.

- Entries in the base system (module)is automatically created.

Important! All configuration files are originally created on the memory card.1. While editing, creating, and restoring the database, make sure that the configuration file name extension,, text "Document - ,, TXT", and the names correspond exactly spelled out in the following table.2. All records (rows) in the configuration files must end official newline sign - ,, ENTER ".3. Configuration files must be in the SET folder.

Page 14: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

Table Nr.2. Remote control. Commands.

Command1 Appointment Record format2 Example entries Note

ADD Adds the numbers in the database of telephonenumbers phone1 (base A) and phone2 (base B)(see. Table Nr.1).A - base index phone1B - base index phone2Important! When adding phone numbers, make surethat the recording made by a serial number (thecorresponding cell) is not occupied by anotherphone number. To do this, use the INF command(see. P. 5.3.)

- Password registered in the base admin (seesection 4.1...)- Separator "semicolon"- ADD command- Separator "semicolon"- Serial number of the record (001-099) (seesection 4.2...)- Base code (A - for phone1 or B - for phone2)which produced a record- Phone number in international format

admin;ADD;099B+37155566667admin;ADD;001А+37155566668

SMS this format is sent to the phonenumber is registered in the baseadmin (see. Point 4.1.) On themodule number.Rooms are added one by one.After the command module sendsSMS on transactions

DEL Removes a number from phone1 database(database A) and phone2 (base B) (see. Nr.1 table)A - base index phone1B - base index phone2

- Password registered in the base admin (seesection 4.1...)- Separator "semicolon"- DEL command- Separator "semicolon"- Serial number of the record (001-099) (seesection 4.2...)- Base code (A - for phone1 or B - for phone2)in which the number is deleted

admin;DEL;020А Rooms are removed one by one.After the command module sendsSMS on transactions

INF Information request about the command entered inthe memory (database of phone numbers phone1and phone2) (see. Table Nr.1) telephone networkcontrol room.A - base index phone1B - base index phone2

- Password registered in the base admin (seesection 4.1...)- Separator "semicolon"- INF command- Separator "semicolon"- Serial number of the record (001-099) (seesection 4.2...)

admin;INF;113A In response to the module telephonenumber from the database admin(see. Table Nr.1) will send an SMSmessage to the phone numbercorresponding to the serial numberentry (cell) (001-099) in the twodatabases (see. P. 4.2.), As wellsame information about the level ofGSM signal.

MIC Allows one-time inclusion of a microphone (one-way communication) with the help of an SMS sentfrom any phone number.Activating the microphone from any phone number- command can be sent from any number. Listening

- The password registered in the base admin- Separator "semicolon"- MIC command

admin;MIC Sent SMS subscriber number of thedevice, activates the microphonefunction. In response, the numbermade to the admin database (. SeeTable 1), the module will send a

1 Recording commands sensitive to letter case.2 Follow the correct procedure for entering characters. All characters are required.

Page 15: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

is possible only through a phone call to the devicefrom the number prescribed in the databasephoneM (see. Table 1)

message «Mic temporary ON" - thefunction is active.After activating the function, callingthe number of the device, with thenumber phoneM made to thedatabase, you can listen to what ishappening in the device.

SPK Allows one-time inclusion of the negotiation unit(bidirectional) by SMS sent from any phone number.Activating the intercom from any phone number -command can be sent from any number.Two-way communication with the module is onlypossible via a phone call to the device from the numberprescribed in the database phoneM (see. Table 1).

- The password registered in the base admin- Separator "semicolon"- SPK command

admin;SPK Sent SMS to the subscriber number ofthe device, activate the intercomfunction.In response, the number made to theadmin database (. See Table 1), themodule will send a message «Mictemporary ON" - the function isactive.After activating the function, callingthe device, communication device willwork in two-way voicecommunication mode (transmission-reception).After completing the call the devicereturns to its initial state.

OUT1outputcontrol viaa telephonecall to themodulenumber

Management first relay switching output OUT1 (see.Fig. 1) by means of a telephone call to the modulenumber from phone numbers registered in databasesphone1 and phone2) (see. Table 1).Time (duration) operation is registered in the databasetime (see. Table Nr.1).

A phone call to the number of the device - Manufactured call any of the phonenumbers registered in databases ofphone numbers phone1 and phone2)(see. P. 4.2.) Triggers the release of therelay switching the OUT1.

ControloutputOUT1through aphone callfrom themodule

Management first relay switching output OUT 1 (seeFigure 1..) By means of a telephone call from themodule: during communication by pressing # on thecontrol handset.This function is only available in the databases of thenumbers spelled phone1 and phone2, the respectivecells (index number 001-004).Time (duration) operation is registered in the databasetime (see. Table Nr.1).

A phone call to the module (click on the outsidepanel room apartment) to control phone number- during communication by pressing # on thehost phone

# button on the controlhandset

By clicking on the entry panel roomapartment module generates a telephonecall numbers (Phone1 base, thecorresponding cell (index number 001-004) (see. P. 4.2.)). If the subscriber isbusy or does not respond within thetime set in the time-based call setup(see. Nr.1 table), the dials of thecorresponding cell phone2 base (see. P.4.2.). If a successful connection is madevoice. And when you press the # key onthe phone initiates operation of OUT1

Page 16: DiTeL GSM - 4 Door - DIGITALas · DiTeL - GSM 4 Door - GSM is an ... Supply voltage 11-14V DC. Current consumption up to 70mA (standby) 150mA (op-eration). ... – separator "semicolon"

output.

OUT2outputmanagement bysending anSMS

OUT2 output activation (see. Fig. 1) for connecting anexternal device by sending an SMS. Sending SMSOUT2 is activated, the output will be OUT2 device100mA, 12V (see. Fig.1).Time (duration) operation is registered in the databasetime (see. Table Nr.1).

- Password registered in the base pass (5characters, case sensitive) (see Table Nr.1.) Sentfrom any phone number

12345 OUT2 is the number ofindependent management - thepassword can be sent to any phonenumber

OUT2outputcontrol viaatelephonecall to themodule

Control output OUT 2 (see Figure 1.). To connectexternal devices via a telephone call to the module:during communication by pressing * on the host phone.This function is only available in the databases of thenumbers spelled phone1 and phone2, the respectivecells (index number 001-004).Time (duration) operation is registered in the databasetime (see. Table Nr.1).

A phone call to the module (click on the outsidepanel room apartment) to control phone number- during communication by pressing * on thehost phone

* button on the controlhandset

By clicking on the entry panel roomapartment module generates a telephonecall numbers (Phone1 base, thecorresponding cell (index number 001-004) (see. P. 4.2.)). If the subscriber isbusy or does not respond within thetime set in the time-based call setup(see. Nr.1 table), the dials of thecorresponding cell phone2 base (see. P.4.2.). If a successful connection is madevoice. And when you press the * key onthe phone triggers the OUT2 output.

_ The microphone function (acoustic control) (see.the MIC command).This function is only available phone number isregistered in the base phoneM (see. Table Nr.1).

A phone call to the number of the device - This function is available afteractivation (single connection)intercom with the help of SMS sentfrom any number. After completingthe call the device returns to itsinitial state.

_ It features two-way communication with theintercom system (see. The SPK command).This function is only available phone number isregistered in the base phoneM (see. Table Nr.1).

A phone call to the number of the device This function is available afteractivation (single connection)intercom with the help of SMS sentfrom any number. After completingthe call the device returns to itsinitial state.

Important! 1. Write command is case-sensitive.2. Ensure that the command is entered in the prescribed format.3. For correct operation of SMS commands must be enabled in receiving an SMS notification only in Latin letters.