Aveo Systems, Inc. 1791 West Oak Parkway Suite 8 Mariea, GA 30062 Phone: +1.678.653.7090 Fax: +1.844.fax.aveo Email: [email protected] www.aveosystems.com R SYSTEMS Samsung Commercial Displays Displays The Samsung Commercial family of displays can be controlled with Mira Connect™, Aveo Systems’ smart control appliance. Mira Connect communicates and controls Samsung Commercial displays either over an Ethernet interface directly to the display or over an RS-232 connecon using the Global Cache IP2SL IP to serial interface. To control the Samsung Commercial display over a direct Ethernet connecon, you must set the Network Standby seng to On in order for API commands to funcon aſter the display has been powered off. Using the display’s IR remote, press the home buon, HOME , and navigate to More Sengs > System > Power Control > Network Standby and select On. If set to ‘Off’ (the default value), the display will not turn on over Ethernet once it has been powered off. To control the Samsung Commercial display over RS-232, press the home buon, HOME , and navigate to ID Sengs > PC Connec 紁瘀 漁Ḁ 瘍d choose RS232C cable. If you don’t make that change, you will not be able to control the system over RS-232. To integrate a Samsung Commercial display with Mira Connect using RS-232, first set up the GlobalCache IP2SL device on the network. Next, add the Samsung Commercial display to the room in Mira Portal (hps://mira.aveosystems.com), enter the IP address of the GlobalCache IP2SL device and press ‘add equipment’. Mira Connect will connect to the Samsung Commercial display and show the status of the connecon. Mira Portal will show the equipment status as a green circle if the connecon is valid, otherwise the warning symbol, ! , will app 崁瘁ᨁ崁ဩ㔮㘠⠁ 㤮㌠⠁鼁瘁倀 騁威Ḁ ⼀圀 ad RS-232 sengs do not match the sengs on the Global Ca ခ威Ḁ ⼀圃帀㸃堀 崠⁔䨊 To specify which video inputs are used on the display, select Edit from the device’s menu, select the Video Inputs tab and enable an input, select an icon, and enter text labels for the desired inputs. This will create a display menu as shown on page 2. While the Mira Connect equipment driver supports all inputs available on Samsung Commercial displays, enable the only parcular video inputs that are available on your display and that you intend to use. See the Mira Connect Administrators Guide for more informaon about using Mira Portal to set up Mira Connect. Important informaon about the integraon is summarized below. Control Interface Opons 1. Network connecon with TCP, port 1515, using the display’s built-in Ethernet interface. While this method does not require a Global Cache IP2SL device, the Samsung Ethernet interface closes its TCP connecon each me the display is powered on. As a result, Mira Connect may indicate that the display has gone offline and then indicate that the display has come back online upon powering on the display. If the display is in a site and room that has text messages enabled, text messages may be sent every me the display is powered on. To prevent text messages on display power up, place the room in Mira Portal to a site that doesn’t have text messaging enabled, or use the Global Cache IP2SL interface to control the display over RS-232. 2. Network connecon with TCP, port 4999, using the Global Cache IP2SL interface. Use Global Cache’s iHelp program to discover the device’s IP address, then browse into the device to set the desired stac IP address and set the baud rate to 9600bps (the default). The GlobalCache IP2SL (part number 151.0010.001) is available as an accessory from Aveo Systems. Ensure the baud rate on the Global Cache IP2SL matches the baud rate configured on the Samsung Commercial display. Default RS-232 sengs for the Samsung Commercial Mira Connect Integraon R SYSTEMS 192.168.80.109 Samsung Professional Equipment ADD

Upload: others

Post on 21-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Displays - Aveo SystemsMira Connect communicates and controls Samsung Commercial displays either over an Ethernet interface directly to the display or over an RS-232 connection using

Aveo Systems, Inc.1791 West Oak ParkwaySuite 8Marietta, GA 30062Phone: +1.678.653.7090Fax: +1.844.fax.aveo Email: [email protected]

R

S Y S T E M S

Samsung Commercial DisplaysDisplays

The Samsung Commercial family of displays can be controlled with Mira Connect™, Aveo Systems’ smart control appliance.

Mira Connect communicates and controls Samsung Commercial displays either over an Ethernet interface directly to the display or over an RS-232 connection using the Global Cache IP2SL IP to serial interface.

To control the Samsung Commercial display over a direct Ethernet connection, you must set the Network Standby setting to On in order for API commands to function after the display has been powered off. Using the display’s IR remote, press the home button, HOME , and navigate to More Settings > System > Power Control > Network Standby and select On. If set to ‘Off’ (the default value), the display will not turn on over Ethernet once it has been powered off.

To control the Samsung Commercial display over RS-232, press the home button, HOME , and navigate to ID Settings > PC Connection Cable and choose RS232C cable. If you don’t make that change, you will not be able to control the system over RS-232.

To integrate a Samsung Commercial display with Mira Connect using RS-232, first set up the GlobalCache IP2SL device on the network. Next, add the Samsung Commercial display to the room in Mira Portal (https://mira.aveosystems.com), enter the IP address of the GlobalCache IP2SL device and press ‘add equipment’.

Mira Connect will connect to the Samsung Commercial display and show the status of the connection. Mira Portal will show the equipment status as a green circle if the connection is valid, otherwise the warning symbol, ! , will appear indicating the IP address is not correct or the display’s RS-232 settings do not match the settings on the Global Cache IP2SL.

To specify which video inputs are used on the display, select Edit from the device’s menu, select the Video Inputs tab and enable an input, select an icon, and enter text labels for the desired inputs. This will create a display menu as shown on page 2. While the Mira Connect equipment driver supports all inputs available on Samsung Commercial displays, enable the only particular video inputs that are available on your display and that you intend to use.

See the Mira Connect Administrators Guide for more information about using Mira Portal to set up Mira Connect.

Important information about the integration is summarized below.

Control Interface Options

1. Network connection with TCP, port 1515, using the display’s built-in Ethernet interface.

While this method does not require a Global Cache IP2SL device, the Samsung Ethernet interface closes its TCP connection each time the display is powered on. As a result, Mira Connect may indicate that the display has gone offline and then indicate that the display has come back online upon powering on the display. If the display is in a site and room that has text messages enabled, text messages may be sent every time the display is powered on. To prevent text messages on display power up, place the room in Mira Portal to a site that doesn’t have text messaging enabled, or use the Global Cache IP2SL interface to control the display over RS-232.

2. Network connection with TCP, port 4999, using the Global Cache IP2SL interface.

Use Global Cache’s iHelp program to discover the device’s IP address, then browse into the device to set the desired static IP address and set the baud rate to 9600bps (the default). The GlobalCache IP2SL (part number 151.0010.001) is available as an accessory from Aveo Systems.

Ensure the baud rate on the Global Cache IP2SL matches the baud rate configured on the Samsung Commercial display. Default RS-232 settings for the Samsung Commercial

Mira Connect Integration

R

S Y S T E M S

192.168.80.109

Samsung Professional

Equipment ADD

Page 2: Displays - Aveo SystemsMira Connect communicates and controls Samsung Commercial displays either over an Ethernet interface directly to the display or over an RS-232 connection using

R

S Y S T E M S

For more information please contact our Sales Department at [email protected].

About Aveo SystemsAveo Systems is a leading provider of intuitive and easy-to-use solutions for audio, video, and collaboration, improving how systems are used and managed by customers world-wide.

DS-11014-001 Version 2018_05_09

Specifications subject to change without notice. Aveo Systems and the Aveo logo are registered trademarks. All other trademarks are the property of their respective owners.

Mira Connect Integration with the Samsung Commercial Displays

ConfigurationTo enable a display menu on Mira Connect, enable the desired video inputs, select an icon, and set the text labels. The display menu will be built and previewed on the Video Inputs tab within Mira Portal. An optional display name may be entered which is useful if you have multiple displays in a room.

displays are 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control. Use an RS-232 cable that you provide as shown in the following figure.

SamsungDisplayGlobal Cache IP2SL

Pin 1Pin 1 Pin 5Pin 5

Pin 9Pin 9

Pin 6Pin 6

Pin Signal12 RX3 TX45 Ground6789

DB9 Female

DB9 MaleDB9 Female

Pin Signal1 TX 2 RX3 4 Ground

3.5mm Male

RS-232 Control Cable DB9F - 3.5mm Male

RS-232 Connectoris a DB9 Male

RS-232 connectoris a 3.5mm socket

Pin 1Pin 3

Pin 4 Pin 2

RS232 IN

Volume ControlThere is no support for volume control of the display. Use a DSP audio conference device or video conferencing system for volume control.

Supported ModelsMira Connect supports the following series of Samsung Commercial displays :

DB, DC, DM, ML-E, OH-E, OM-E, PH, PM, PH-E, QH-E, QM-E, SH, UD, UH, UM, SyncMaster and other Samsung display families that use Samsung’s API commands.

Software VersionsTested with Samsung Commercial DM32E with firmware version T-GFSLE2AKUC-1037.2.