display 3d... display 3d user manual 5 dmx mode: operating in a dmx control mode environment gives...

8
Order code: LEDJ450 Display 3D User Manual

Upload: others

Post on 23-Mar-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

Order code: LEDJ450

Display 3D User Manual

Page 2: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.

• WARRANTY:Oneyearfromdateofpurchase.

Page 3: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 3

Product overview & technical specifications

TheDisplay3DarehexagonalshapedLEDpanelscreating3Dvisualeffects.Designedfornightclubs,bars,stagesandentertainers,thesepanelsarecontrollableviaDMX.MultiplepanelscanbelinkedtogetherviathePowerCONinput/outputandRJ45signalinput/outputfordatalinking.Panelscanbelockedtogetherwiththeincluded,quicklockconnector(oneperpanel)orthefixingbracket(oneperpanel).HangingbracketsarealsoavailableforinstallationortheM10threadontherearofeachpanelcanbeusedwithvariousclamps.

Display 3D

• 72tri-colourSMD5050LEDs(RGB)

• Viewingangle:180°

• DMXchannels:9

• DMXmode

• Display3DPanelswillnotoperatewithoutDisplay3DDMXEncoder-(Ordercode:LEDJ461)

• Quicklockconnectorandfixingbracketincluded(oneofeachperpanel)

• M10threadonrearfortrussmountingviaaclamp

• PowerCONinput/output

• RJ45signalinput/output

• Convectioncooled

Specifications Display 3D

Powerconsumption 13W

Powersupply 100-240V~50/60Hz

Fuse F1A250V

Dimensions 420x350x83mm

Weight 2.8kg

Ordercode LEDJ450

350mm

420mm

205mm

205mm

83mm

42mm

Page 4: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 4

Pixel 1

Pixel 3 Pixel 2

Technical specifications

01-PowerCONinput

02-PowerCONoutput

03-RJ45signalinput

04-RJ45signaloutput

05-Fuse:F1A250V

06-Earthpoint

07-Safetyeye

08-Quicklockconnector/fixingbracketmountingpoints

09-M10riggingpoint

Eachsetof4Display3DPanelsaresuppliedwith:4 x Display 3D Panels, 1 x 13A PowerCON cable, 3 x 0.5m PowerCON link cables, 4 x RJ45 link cables, 4 x safety wires, 4 x quick lock connectors, 4 x fixing brackets with 8 x thumbscrews, & 1 x user manualSubsequentextraPanelswillbesuppliedwith:1 x Display 3D Panel, 1 x quick lock connector, 1 x fixing bracket with 2 x thumbscrews, 1 x 0.5m PowerCON link cable, 1 x RJ45 link cable, & 1 x safety wire

PO

WER

INP

UT: 1

00

-240

V~5

0/6

0H

zP

OW

ER O

UTP

UT:

10

0-2

40

V~5

0/6

0H

zS

IGN

AL IN

PU

TS

IGN

AL

OU

TPU

T

www.prolight.co.uk

DISPLAY 3D

PIXEL 1

07

07

0908 08

080808 08

07

02 01

06

0304

05

Page 5: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 5

DMX mode:

OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.

TheDMXaddresscanbeprogrammedviatheDisplay3DDMXEncoder-Ordercode:LEDJ461(soldseparately).

Operating instructions

Channel Value Function

1 000-255 Pixel1Red0-100%

2 000-255 Pixel1Green0-100%

3 000-255 Pixel1Blue0-100%

4 000-255 Pixel2Red0-100%

5 000-255 Pixel2Green0-100%

6 000-255 Pixel2Blue0-100%

7 000-255 Pixel3Red0-100%

8 000-255 Pixel3Green0-100%

9 000-255 Pixel3Blue0-100%

9 channel mode:

Page 6: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 6

Installation:

TheDisplay3DPanelisdesignedtobemountedviatheoptionalhangingbracket(Ordercode:LEDJ466)orfromtheM10riggingpointontherearoftheunit.Theunitscanbefixedtogetherwiththequicklockconnectors(oneprovidedperpanel)orthefixedbracket(oneprovidedperpanel).Please note: -Additionalquicklockconnectorsandfixedbracketsmayberequiredincertainorientations.-ThemaximumnumberofDisplay3Dpanelsthatcanbeconnectedareasfollows: Power-16panelsvia1x13APowerCONcablefollowedby15PowerCONlinkcables DMXsignal-32panelsviaRJ45signalcables.-Provided0.5mPowerCONlinkcableswillonlyconnectamaximumof4piecesincertainorientations.0.75m/1mPowerCONlinkcablesmayberequired.

Mounting example:

Installation

RJ45cablessoldseparatelyandcanbepurchasedfrommostProlightConceptsdealers.Pleasequote:CABL260 – 0.5m CABL261 – 1m CABL262 – 2m CABL263 – 5m CABL264 – 10m

PowerCONlinkcablessoldseparatelyandcanbepurchasedfrommostProlightConceptsdealers.Pleasequote:CABL234 – 1m CABL235 – 1.5m CABL236 – 2m CABL238 – 5m CABL239 – 10m

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

POWER INPUT: 100-240V~50/60Hz

POWER OUTPUT: 100-240V~50/60Hz

SIGNAL INPUT

SIGNAL OUTPUT

ww

w.p

rolig

ht.c

o.uk

DIS

PLA

Y 3

D

PIX

EL 1

Page 7: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 7

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

Page 8: Display 3D... Display 3D User Manual 5 DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show

www.prolight.co.uk Display 3D User Manual 8