discharge studies in mpgd: what could be done in the frame of wg-2 collaboration p. fonte, v. peskov
DESCRIPTION
Discharges in MPGDsTRANSCRIPT
![Page 1: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/1.jpg)
Discharge Studies in MPGD: what could be done in the frame of WG-2
collaboration
P. Fonte, V. Peskov
![Page 2: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/2.jpg)
WG-2 tasks
(from the RD-51 proposal)
![Page 3: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/3.jpg)
Discharges in MPGDs
![Page 4: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/4.jpg)
I) In bad quality detectors – imperfections
II) In good quality detectors - there are several fundamental reasons:
1) Raether limit2) Rate effect 3) Jets4) Feedbacks5) Surface streamers
Want cause the breakdowns?
![Page 5: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/5.jpg)
Imperfections:
Usually cause persisting discharges at the fixed place in
the detector
![Page 6: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/6.jpg)
a)
b)
c)
d)
Ideal holes
Holes with sharp edges
Holes with debris or dust particles
Holes with areas of slightly conductive surfaces (dirt)
-+
Cathode
Anode
Examples for hole-type gas amplifiers:
Common « standards »: before comparing maximum achievable gains one have to verify that the discharges are randomly distributed over the detector surface
![Page 7: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/7.jpg)
1)Raether limit
![Page 8: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/8.jpg)
At Amaxn0 ≥Qmax=108 electrons an avalanche transits to a spark.
Amaxn0=108 is called a Raether limit.
Discharges in parallel-plate geometry
![Page 9: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/9.jpg)
Raether limit fro MPGDs:
It was recently discovered that a similar limit applies for every micropattern detectors:
GEMs, MICROMEGAS and others:Amaxn0=Qmax=106-107 electrons,
where n0 is the number of primary electrons created in the drift region of the detector
(Qmax depends on the detector geometry and the gas composition)
(see Y. Ivanchenkov et al., NIM A422,1999,300 andV. Peskov et al., IEEE Nucl. Sci. 48, 2001, 1070)
![Page 10: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/10.jpg)
Conclusions:
With single primary electrons gains up to 106-107 in principle are possible
With 55Fe (n0~230 electrons) the maximum achievable gain is <105
With alphas (n0=105) the maximum achievable gain <100
This was well observed in the case of MPGDs
![Page 11: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/11.jpg)
MPGD CERTIFICATIONMPGD CERTIFICATION
DETECTODETECTORR
MAX MAX GAINGAIN
MAX MAX CHARCHAR
GEGE
MSGCMSGC 20002000 4 104 1077
ADV ADV PASS PASS MSGCMSGC
10001000 2 102 1077
MICROWMICROWELLELL
22002200 4.4 104.4 1077
MICROMEMICROMEGASGAS
30003000 6 106 1077
GEMGEM 20002000 4 104 1077
The maximum gain before discharge is almost the The maximum gain before discharge is almost the same for all MPGD tested: same for all MPGD tested:
S. Bachmann et al, Nucl. Instr. and Meth. A479(2002)294S. Bachmann et al, Nucl. Instr. and Meth. A479(2002)294
~3000~3000
~2000~2000
MEASURE GAIN WITH MEASURE GAIN WITH 5555Fe X-RAYS AND DISCHARGE PROBABILITY WITH INTERNAL ALPHA SOURCE FROM Fe X-RAYS AND DISCHARGE PROBABILITY WITH INTERNAL ALPHA SOURCE FROM 220220Rn Rn
MICROMEGAS MICROMEGAS
GEM GEM
F. Sauli, Report at the RD51 collaboration meeting in Amsterdam, 2008
![Page 12: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/12.jpg)
Maximal gains with UV are 100 times higher than with X-rays.For UV and x-ray gun:The current in the plateau region (500-750V) was the same: 0.1nA. The maximum current in gain measurements was always kept below 0.5nA
Ar+5%CH4=1atm
1.00E-02
1.00E+00
1.00E+02
1.00E+04
1.00E+06
0 500 1000 1500 2000 2500
Voltage (V)
Gai
n UV light
X-rays 55Fe NEWPulse-mode(~1kHz)
Cu X-ray gun, current-mode
Single-THGEM : Ar+5%CH4
WIS old pulse-mode
UVCurrent-modeNEW
104
THGEM geometry:Holes dia: 0.5 mm Pitch: 1 mmThickness: 0.8 mmRim: 0.1mm
A. Breskin, V. Peskov et al, Report at the RD51 meeting in Paris, 2008
![Page 13: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/13.jpg)
What was established up to now is just a general picture
Detailed studies are still needed:a) Simulationsb) Geometry and gas optimization
![Page 14: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/14.jpg)
Geometrical optimization?
![Page 15: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/15.jpg)
Regions with parallel fields lines where any streamer, if appear, is unquenched and may reach the cathode
Why there are sparks in micropattern gaseous detectors?
Because there are regions with parallel field lines, so streamers develop there by thesame mechanism as in PPAC
![Page 16: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/16.jpg)
Transition to streamer occurs whenAn0≥Qmax=108electros
Self-quenched streamer
Strimers give huge amplitudes but the are not harmful as well
Streamers cannot propagateto the cathode because theelectric field drops as 1/r
Streamer
![Page 17: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/17.jpg)
Signal’s amplitude in proportional and streamer modes
For details see: P. Fonte et al., INFN Insrum. Bull, SLAC-Journal ICFA-15-1, 1997
![Page 18: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/18.jpg)
The main designs of micropattern gaseous detectors
Microstrip gaseous detectors
Microdot gaseous detectors
MICROMEGASGEM
25-100μm
25-100μm
25μm
140μm
![Page 19: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/19.jpg)
Empirical way to increase the Raethet limit: multistep detectors
Raethre limit increases due to the diffusion effect?
![Page 20: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/20.jpg)
Gas optimization?
![Page 21: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/21.jpg)
Gain in Ne=1atm
1.00E-03
1.00E-021.00E-01
1.00E+001.00E+01
1.00E+02
1.00E+031.00E+04
1.00E+051.00E+06
1.00E+07
50 150 250 350 450 550
Voltage (V)
Gai
n
UV lightFe old
(prtection box)
Fe new(no protection box)
Single-THGEM: Ne
UV, current-mode
55FePulse-mode
The maximum gains with x-rays in Ne are higher than in Ar+5%CH4.In Ne breakdown voltages with UV and X-rays are closer.
104
THGEM geometry:Holes dia: 0.5 mm Pitch: 1 mmThickness: 0.8 mmRim: 0.1mm
104
A. Breskin, V. Peskov et al, Report at the RD51 meeting in Paris, 2008
![Page 22: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/22.jpg)
Single-THGEM: Ne + CH4
Gains in Ne+5%CH4
1.00E-011.00E+00
1.00E+011.00E+02
1.00E+031.00E+04
1.00E+051.00E+06
0 200 400 600 800 1000 1200
Voltage (V)
Gai
n
UVFe
Ne+23%CH4
1.00E-011.00E+00
1.00E+011.00E+02
1.00E+031.00E+04
1.00E+051.00E+06
0 500 1000 1500 2000 2500
Voltage (V)
Gai
n
Fe
Same as with Ne: maximum gains with x-rays in Ne+CH4 are higher than in Ar+5%CH4 and breakdown voltages with UV and X-rays are close.
55FePulse-mode
55FePulse-mode
UVCurrent-mode
UVCurrent-mode
THGEM geometry:Holes dia: 0.5 mm Pitch: 1 mmThickness: 0.8 mmRim: 0.1mm
104104
104 104
A. Breskin, V. Peskov et al, Report at the RD51 meeting in Paris, 2008
![Page 23: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/23.jpg)
A possible interpretation:
- Raether limit: established in large-gap avalanche detectors but valid for MPGDs (Ivanchenkov NIM A 1999), though may be different
- A*n0=106-107 electrons where A is the maximum achievable gain, n0-number of primary electrons deposited by the radiation in the drift region X-rays: different gain compared to UV
- In Ne/CH4 Raether limit possibly differs from Ar/CH4 due to ~ 5-fold longer range of 55Fe photoelectrons (~1mm), resulting in lower ioinization density per “hole”.
![Page 24: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/24.jpg)
More details…
![Page 25: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/25.jpg)
Raether limit for PPAC and MICROMEGAS is reached at n0>50 electrons
V. Peskov et al., IEEE Nucl. Sci. 48,2001,1070
PPACRaetherlimit
MICROMEGASRaetherlimit
![Page 26: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/26.jpg)
For n0>50 electrons “Rather” limit works well, however for n0<20 electronsother factor starts dominating like field emission from sharp edges, gain fluctuation…
PPACRaetherlimit
Single GEMRaether limit
..similar for GEM-type detectors
V. Peskov et al., IEEE Nucl. Sci. 48,2001,1070
![Page 27: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/27.jpg)
Proposed “common standards" in discharge studies and comparisons
●Discharges should be randomly distributes over the detector surface.
● For Raether limit verification use: UV light, 55Fe and alphas
● Measure not only discharge rate vs. applied voltage, but the discharge energy and evaluate the destructive effect (some detector may die after one sparks others
withstand hundred of sparks)
![Page 28: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/28.jpg)
2) Rate effect
![Page 29: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/29.jpg)
Amax
Parallel plate detector (PPAC)
Signal amplitude does not drop with rate, however there is a rate limit for each amplitude
Amplitudes
P. Fonte et al IEEE Nucl. Sci46,1999,321
![Page 30: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/30.jpg)
Amax
For each micropattern detector the amplitude remains unchanged with rate, however the maximum achievable gain drops with rate
Rate limit of micropattern gaseous detectors
Amplitudes
P. Fonte et al,NIM A419,1998,405
![Page 31: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/31.jpg)
Common “standards”:
When reporting rate indices sparks one have to mention at what gas gain
this was measured/observed
![Page 32: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/32.jpg)
3) Jets
![Page 33: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/33.jpg)
Electron jets:
P. Fonte et al., IEEE Nuc. Sci46,1999,321
![Page 34: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/34.jpg)
![Page 35: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/35.jpg)
![Page 36: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/36.jpg)
Other evidences:
Hysteresis: one cannot apply the voltage immediately after the breakdown
(“Memory effect” well documented in the case of RPC and Compass RICH
Depends on gas
This effect should be studied as well
![Page 37: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/37.jpg)
4) Feedbacks (essential for detector operating in noble gases or combined with
photocathodes)
Afγ=1(Afγ+=1 or Afγph=1)-”slow” mechanism of discharges
The probabilities γ+ and γph are increasing with the increasing thephotocathode QE and it’s sensitivity to visible light and with electric field near the cathode
![Page 38: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/38.jpg)
5) Surface streamers
![Page 39: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/39.jpg)
HVAmplifierSurface streamer
V. Peskov et al., NIM A397,1997, 243
![Page 40: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/40.jpg)
Discharges “prevention:”
Increase or “bypass” the Raether limit( gas optimization, detector geometry optimization/multistep
approach) Reduce feedbacks (when it is
essential) Any other measures..? Not too
much…
![Page 41: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/41.jpg)
Examples:
Resistive GEMs
Strip electrodes terminated on resistors (V. Peskov et al report at IEEE Nucl Sci, Dresden 2008)
MICROMEGAs with resistive coating (see Van Der Graaf presentation)
Spark-proofed MPGDs
![Page 42: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/42.jpg)
Optimization of the RPC electrodes resistivity
![Page 43: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/43.jpg)
Instead of conclusions:
●A lot of work is required to better understand discharges and protection against
the discharges ● We can try to identify today who is
interested to participate in these studies and how
● One of the possible way is to cluster these studies around CERN-Coimbra –Weizmann
institute where this activity was already started and enforce the local teams with
visitors● Any other suggestion are very welcome
![Page 44: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/44.jpg)
Spairs
![Page 45: Discharge Studies in MPGD: what could be done in the frame of WG-2 collaboration P. Fonte, V. Peskov](https://reader033.vdocuments.mx/reader033/viewer/2022052607/5a4d1b4b7f8b9ab0599a5552/html5/thumbnails/45.jpg)
Possible discussion topics at WG-2 meeting at CERN:1. Raether limit for micropattern detectors:
a)Experimental evidence, simulations, possible ways of its increasing (gases, geometry)
b)Rate induced breakdowns:Avalanche overlapping and Raether limit
2. Cathode excitation effect at low and high counting rates :a) Hysteresis in breakdown voltage
b) Long-term discharge memory effectc)Jets of electrons
3. Common “standards”:a) Speaks measurements (distinguish sparks due to defect from sparks due to
the Raether limit)How we compare sparks: spark energy, sparks rate
How we evaluate spark damages (after how many spars the detector dies?)?b)Gain measurements: ionization chamber vs. charge injection methodec) Gain stability (due to the charging up effect and dielectric polarization):
Low rateHigh rate
Short-term stabilityLong-term stability
d) Quantum efficiency measurements for photosensitive micropattern detectors- what should be a common reference: TMAE, calibrated detectors,
Cherenkov light?