DirectFill(PartNumberINJ-DF)DirectFillAssembly
forPhiladelphiaScientific®WaterInjectorSystems™
PAK063:INJ-DFInstructions11/27/201312:02PMPage1
![Page 2: DirectFill - phlsci.comPhiladelphiaScientificLLC. 207ProgressDrive Montgomeryville,PA18936 P:215.616.0390 F:215.616.0500 PAK063 Rev 3 /201 6 ©201 6 PhiladelphiaScientificLLC](https://reader034.vdocuments.mx/reader034/viewer/2022042308/5ed4ef994ccda7354c07275a/html5/thumbnails/2.jpg)
Do not fill the Direct Fill directly from afaucet.
The static water pressure may notexceed 80 PSI (25 bar).
ABall Valve with a 3/4” NPTmale threadedfitting must be plumbed in to a pressurizedwater line (>3/4” or more in diameter).
Not included
Attach the black sediment filter to theoutlet of the Ball Valve.
Attach the red hose to the white maleend of the sediment filter. Do not usemore than 20 ft. of hose
Attach the Pressure Regulator to theend of the red hose.
Attach the Instant Valve Pro™ to theend of the Pressure Regulator
Mount included brackets on the wall.
Turn water source on at the ball valve. Connect the Instant Valve Pro™ to theInput Assembly of the Water InjectorSystemÊ installed on the battery.
Squeeze the lever completely to fill thebattery. Do Not Partially Squeeze theLever.
Watch the spinner mounted on theInstant Valve Pro. When it stopsspinning, the filling is completed.
Release the lever and then disconnectthe Instant Valve Pro from the WaterInjector System.
Move on to the next battery. Whenfinished watering batteries, turn thewater off at the ball valve.
Operation:
PAK063:INJ-DF Instructions 11/27/2013 12:02 PM Page 2
Installation:The Philadelphia Scientific Water Injector System requires a water flow ofapproximately 8-10 gallons per minute at 25-35 psi or more. This can bequalified with a Flow Checker (INJ-FC). If your water supply does not meetthese requirements, you will need to purchase an alternative to the Direct Fill.