8/14/2019 Diji 1kva-10kva http://slidepdf.com/reader/full/diji-1kva-10kva 1/2 DIGIGATE Series Built to Last... Online HF UPS 1KVA-10KVA www.apec.sa.com Applicaons Centralized server center, network control center, Informaon Center, Healthcare, Telecommunicaon Features: Adopt DSP digital control technology - Adopt advanced DSP digital control technology, it imroves performance & system reliability effecvely, and achieves higher level of power density and miniaturizaon. - Besides that, it can meet all customers individualized needs, DIGIGATE Series 1-10KVA provide very rich extensible funcon, users can configure the need flexibly. Output Power factor 0.9 PF 0.9 is more suitable for the trend of electrical equipment and can take more load. With new ECO(Economic) funcon, system efficiency can achieve 94%, it lower UPS power consumpon and save user ’s cost. Input PFC Adopt didgital control input PFC technology, Input Power Factor can be more than 0.98, It avoids polluon to power grid, saves energy and also reduce cost. Digital Control at DC-DC Converter DIGIGATE Series 1-3KVA UPS adopt digital control use Digital Control at DC-DC converter part instead of Analog Control in the past and it is more reliable. Wide input voltage range Extremely wide input voltage and frequency range, even in very poor power environment of the remote areas can normally supply the power. It reduced the frequency of baery discharge so that the baery life can be prolonged. Perfect protecon - The UPS contain I/P and O/P over-protecon, short voltage protecon, overload protecon, short-circuit protecon, inverter over-heat protecon, baery low voltage warning protecon and baery overcharge protecon, etc. Which is the above greatly ensure the stability of running the system. - With bypass funcon, when the output overload or UPS failure, can turn to bypass without interrupon and supply power to load by mains supply, accordingly provide alarm informaon. - With input I and N lines detecve funcon can prevent the danger caused by the inversion of L and N lines. Cold start and mains power start funcon - For emergency status, UPS can start with baery directly when the mains power anomalies. - UPS can start directly without baery can be used for high precision stabilizer Compable with generatorsnt Wide range of input voltage and frequency that can affecvely isolate the adverse power from generator can provide clean, safe and stable power supply the lead. Intelligent Baery Management - It adopts intelligent management technology to charge by three steps, to effecvely extend baery life and reduce the number of baery maintenance. The baery can be self tesng to find baery problem mely. - With baery voltage, overcharge protecon, etc. to maximize the protecon of the baery is not damaged.

Upload: santhu-meprathu

Post on 04-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Diji 1kva-10kva

8/14/2019 Diji 1kva-10kva

http://slidepdf.com/reader/full/diji-1kva-10kva 1/2

DIGIGATE SeriesBuilt to Last...

Online HF UPS 1KVA-10KVA

www.apec.sa.com

Applicaons

Centralized server center, network controlcenter, Informaon Center, Healthcare,

Telecommunicaon

Features:Adopt DSP digital control technology

- Adopt advanced DSP digital control technology, it imroves performance &

system reliability effecvely, and achieves higher level of power density

and miniaturizaon.

- Besides that, it can meet all customers individualized needs, DIGIGATE

Series 1-10KVA provide very rich extensible funcon, users can configure

the need flexibly.

Output Power factor 0.9

PF 0.9 is more suitable for the trend of electrical equipment and can take

more load. With new ECO(Economic) funcon, system efficiency canachieve 94%, it lower UPS power consumpon and save user ’s cost.

Input PFC

Adopt didgital control input PFC technology, Input Power Factor can be

more than 0.98, It avoids polluon to power grid, saves energy and also

reduce cost.

Digital Control at DC-DC Converter

DIGIGATE Series 1-3KVA UPS adopt digital control use Digital Control at

DC-DC converter part instead of Analog Control in the past and it is more

reliable.

Wide input voltage range

Extremely wide input voltage and frequency range, even in very poor

power environment of the remote areas can normally supply the power. Itreduced the frequency of baery discharge so that the baery life can be

prolonged.

Perfect protecon

- The UPS contain I/P and O/P over-protecon, short voltage protecon,

overload protecon, short-circuit protecon, inverter over-heat

protecon, baery low voltage warning protecon and baery overcharge

protecon, etc. Which is the above greatly ensure the stability of running

the system.

- With bypass funcon, when the output overload or UPS failure, can turn

to bypass without interrupon and supply power to load by mains supply,

accordingly provide alarm informaon.

- With input I and N lines detecve funcon can prevent the danger caused

by the inversion of L and N lines.

Cold start and mains power start funcon

- For emergency status, UPS can start with baery directly when the mains

power anomalies.

- UPS can start directly without baery can be used for high precision

stabilizer

Compable with generatorsnt

Wide range of input voltage and frequency that can affecvely isolate the

adverse power from generator can provide clean, safe and stable power

supply the lead.

Intelligent Baery Management

- It adopts intelligent management technology to charge by three steps, toeffecvely extend baery life and reduce the number of baery

maintenance. The baery can be self tesng to find baery problem

mely.

- With baery voltage, overcharge protecon, etc. to maximize the

protecon of the baery is not damaged.

Page 2: Diji 1kva-10kva

8/14/2019 Diji 1kva-10kva

http://slidepdf.com/reader/full/diji-1kva-10kva 2/2

Rated Capacity 1KVA 2KVA 3KVA 6KVA 10KVA

Rated Input voltage

Rated Input frequency

Input voltage range

Input frequency rangeInput current   8A max 15A max 23A max 46A max 76A max

Power factorTHDIBypass Voltage Range

Output voltage

Output PF

Output power(VA/Wa) 900 1800 2700 5400   9000

Inverter overload capability (Transfer to

bypass)

Voltage accuracyLoad crest

Transfer Time

Under Mains Mode

Under Baery Mode

Phase-Locked Rate

Total Voltage Harmonic Distorton

Baery TypeQuantty  2   4 6DC voltage 24V   48V 72V

Input Baery 9AH/12V   9AH/12V   9AH/12VCharging Voltage 27.1 ± 0.4V 54.2 ± 0.6VBack up TimeCharging Method

Functon

Protecton

Communicaton Port

Sofware Functon

Display

Noise

6/7.5 12/13.5 13/14.5

440x468x88(with internal baery)

580x590x200(with internal baery)

12/13.5 28/29.5   33/34.50

Specificatons

Charging Current: Standard Model

  Long tme model

Efficiency: Mains Mode

  BAT Mode

  ECO Mode

Operatng Envirnoment: Operaton temp

  Store temp

  Humidity

  Alttude

From AC mode to BAT mode:0ms ; From BAT mode to AC Mode: 0ms

From Main mode to bypass mode:4ms ; From bypass mode to mains mode:4msFrom normal mode to ECO mode:10ms

≥90% (full load) ≥92% (full load)

87% 90%

98% 98%

OUTPUT FREQUENCY

Long back tme model: Dimensions

  (WxDxH) mm

  Packing Dimension

  (WxDxH) mm

  Net/Gross Weight(Kg)

220VAC

50Hz/60Hz Auto Adapton

(115-295) ±5VAC(half load);(145-295)±5VAC(full load)

45-55Hz ±0.5% 50Hz type : 55-65Hz ±5% 60Hz type

≥0.98 ≥0.99<6% <5%

Rated output voltage-34V - Rated output Voltage +34V

OUTPUT

0.9

105%-150%:30s ; ˃150%:300ms

105%-125%:3min;125%-

150%:30s

±0.23:01

Same as Input Frequency

(50/60 ±0.2)Hz

≤1Hz/s

Full linear load <3% ; Full nonl inear load <5%

BATTERYSealed lead acid maintainance free baery

16192V

9AH/12V216.8 ± 1V

1A

6A 1A/3A/5A/8A

SYSTEM CONTROL AND COMMUNICATION

Silence ; cold start ; AC restart ; Auto restart

20-90% (non-condensing)

0m<alttude<1500m,over 1500m,used with power derated

50dB 55dB

Over-temp protecton ; Fan testng protecton ; AC L and N reversely connectng

protecton; Output short circuit protecton

RS232(standard) : USB and SNMP card (opton)Graphic analyze: Switch On/Off  UPS system : Montor UPS working status:

History record and event log

LCD+LED

SYSTEM OPERATING ENVIRNOMENT

208VAC/210VAC/220VAC/230VAC/240VAC Seng Available

Based On baery CapacityThree-Stage Charging

Standard model: Dimensions

  (WxDxH) mm

 

Packing Dimension

  (WxDxH) mm

  Net/Gross Weight(Kg)

440x640x88(with internal baery)

440x565x132 (UPS)

440x565x132 (BAT)

530x710x170(with internal baery)

535x660x215(UPS)

546x676x266(BAT)

19/21.5(UPS) 52/54.5(BAT)

440 x 468 x 88 440 x 565 x 132

580x590x200 535x660x215

19/21.5

0-40 °C

25%°C - 55°C

www.apec.sa.com

P.O. Box 3411, Al Khobar 31952 - Saudi Arabia

Tel: +966 13 890 1261 Fax: +966 13 865 0066

E-mail: [email protected]

ARABIAN POWER ELECTRONICS COMPANY

   D   G    C

   a   t .   0

   8 .   1

   3

Note: i) All specificaons subject to change without noce

  ii) Custom-made specificaons are acceptable

Overcurrent Protecon

AC Input

Modem/Tel/Fax

DC Input

Outlet

FAN

RS232

SNMP/USB/AS400(Oponal)

1

1

2

3

4

5

6

7

8

Rear Panel