Digital Tachometer ©1999 Dynalco Controls 0899F The LST-100™ Series features a field-selectable pulse rate multi- plier that can increase signal pulse rate by a factor of 10 or 100. The units are particularly useful when input frequency is low, resulting in too slow an update rate (gate time), or for applications where signal amplitude is minimal because of low shaft speed or large pickup- to-gear gap. LST-100 Series 2-Year Warranty Features l Standard SAE case fits engine panels with 3.37 inch (8.6 centimeter) openings. l Highly shock and vibration resistant. Gasketed and spray-proof. l Universal: Can be field-calibrated for any number of pulses per revolution from the sensor. l Ideal for OEM use. Can be paralleled with governors and/or speed switches. l High immunity to electrical noise. l Display contrast increases with increasing ambient light; ideal for both indoor and outdoor installation. Units are also available in lighted versions (LST-100L or LST-108L). l The pulse rate multiplier increases input frequency which permits calibration at a much shorter gate time. l Tachometer can be factory configured for different input types i.e. TTL, CMOS, magnetic pickups, etc. Specify which type when ordering. Specifications l Power Requirement: 10 to 30 Vdc or 115 Vac ±10%, 50/60 Hz, 8 mAdc typical. LST-100L and LST-108L are powered with 20 to 30 Vdc only. l Display: 4 active digits (0 to 9999), non- blinking LCD display, character height of 0.5 inch (1.3 centimeters). l Input Signal Frequency: Signal frequency up to 10,000 Hz, except contact closure. l Contact Closure Input Option: 0-200 Hz. l Input Signal Voltage: 25 mVrms sensitivity for the standard unit which accepts zero crossing waveforms from pickups, generators, and pulsers. Nominal input resistance of 10 kΩΩ ΩΩ . Maximum permissible signal 50 Vrms. TTL option accepts unidirectional positive pulses from 0 to +5 volts, up to 0 to +15 volts. l Signal Common: Signal common is tied internally to the negative side of the dc supply. l Operating Environment: (operating) –5°F to +175°F(–20°C to +80°C); (storage) –40°F to +195°F (–40°C to +90°C ). 3690 N.W. 53rd Street, Fort Lauderdale, FL 33309 U.S.A. (954) 739-4300 Fax: (954) 484-3376 Website: www.dynalco.com (713)-395-1508 Fax: (713) 893-6924 [email protected] www.industrialzone.com IndustrialZone P.O. Box 667306 Houston, Texas 77266 United States

Upload: others

Post on 29-Nov-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Digital Tachometer - IndustrialZone

DigitalTachometer

©1999 Dynalco Controls 0899F

The LST-100™ Series features afield-selectable pulse rate multi-plier that can increase signal pulserate by a factor of 10 or 100. Theunits are particularly useful wheninput frequency is low, resulting intoo slow an update rate (gate time),or for applications where signalamplitude is minimal because oflow shaft speed or large pickup-to-gear gap.

LST-100 Series

2-Year Warranty

Features Standard SAE case fits engine panels with

3.37 inch (8.6 centimeter) openings. Highly shock and vibration resistant.

Gasketed and spray-proof. Universal: Can be field-calibrated for any

number of pulses per revolution from thesensor.

Ideal for OEM use. Can be paralleled withgovernors and/or speed switches.

High immunity to electrical noise. Display contrast increases with increasing

ambient light; ideal for both indoor andoutdoor installation. Units are also availablein lighted versions (LST-100L or LST-108L).

The pulse rate multiplier increases inputfrequency which permits calibration at amuch shorter gate time.

Tachometer can be factory configured fordifferent input types i.e. TTL, CMOS,magnetic pickups, etc. Specify which typewhen ordering.

Specifications Power Requirement: 10 to 30 Vdc or 115

Vac ±10%, 50/60 Hz, 8 mAdc typical.LST-100L and LST-108L are poweredwith 20 to 30 Vdc only.

Display: 4 active digits (0 to 9999), non-blinking LCD display, character height of0.5 inch (1.3 centimeters).

Input Signal Frequency: Signal frequencyup to 10,000 Hz, except contact closure.

Contact Closure Input Option: 0-200 Hz. Input Signal Voltage: 25 mVrms sensitivity

for the standard unit which accepts zerocrossing waveforms from pickups,generators, and pulsers. Nominal inputresistance of 10 kΩΩΩΩΩ. Maximum permissiblesignal 50 Vrms. TTL option acceptsunidirectional positive pulses from 0 to +5volts, up to 0 to +15 volts.

Signal Common: Signal common is tiedinternally to the negative side of the dcsupply.

Operating Environment: (operating) –5°Fto +175°F(–20°C to +80°C); (storage) –40°Fto +195°F (–40°C to +90°C ).

3690 N.W. 53rd Street, Fort Lauderdale, FL 33309 U.S.A. (954) 739-4300 • Fax: (954) 484-3376 • Website: www.dynalco.com

(713)-395-1508Fax: (713) [email protected]

IndustrialZoneP.O. Box 667306Houston, Texas 77266United States

Page 2: Digital Tachometer - IndustrialZone

Accuracy: 1 RPM resolution, within ± 0.5%(± 0.1% typical at room ambient) under allcombined environmental conditions.

Gate Time Adjust: Gate time is set byselecting one of four ranges on a switch andby a 25-turn vernier control potentiometer.Both controls are accessible from the backof the tachometer through a plugged hole.

Gate time ranges (LST-100 & 100L):(1) 0.26–0.72; (2) 0.72–1.43; (3) 1.43–2.8;(4) 2.85–5.70.

Gate time ranges (LST-108 & 108L):(1) 0.13–0.36; (2) 0.36–0.72; (3) 0.72–1.43;(4) 1.43–2.85.

Recommended Magnetic Pickups:Dynalco Controls magnetic pickup M102 isused with the LST-100 Series in mostapplications. For very low speed applicationsthe Dynalco Controls ultrahigh sensitivityM142 and the zero-velocity M910 arerecommended. Refer to the Dynalco ControlsMagnetic Pickups Brochure for a descriptionof these and other pickups.

Weight: 0.8 pounds (0.36 kg)

Outline and Connection Drawings

LST-100 Series and LST-108 Series are trademarks of Dynalco Controls.DYNALCO CONTROLS RESERVES THE RIGHT TO CHANGE THESE SPECIFICATIONS WITHOUT NOTICE.

FOR COMPLETE SPECIFICATION INFORMATION, CONTACT A DYNALCO REPRESENTATIVE.

How to Order Specify the LST-100 or the

LST-108. Refer to gate time rangeswhen ordering the LST-100 orLST-108. Unit also available in theLST-100L and LST-108L (lightedversion). (XP Enclosure availablethrough the factory).

Specify the LST-100-1 for use withmagnetic pickups, ac generators,and other zero-crossing waveformgenerators.

Specify the LST-100-2 for use withsignal sources with unidirectionalpositive output pulses such as TTL,CMOS, Dynalco Controls PG-278,M910 pickup, etc.

Specify the LST-100-3 for contactclosure input.

(713)-395-1508Fax: (713) [email protected]