digital multimeter -...

9
/ F 6 DIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product! As our customers are our top priority and we strive for 100% satisfaction, we would appreciate your feedback on the product. Please contact us if you have any questions regarding the product. Our professional support team is always ready to answer your enquiries and provide assistance. MS8302F

Upload: others

Post on 10-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

/

F

6

DIGITAL MULTIMETER

CAT.III

600V

SERVICE

00-05-3768

Thank you for purchasing our product! As our customers are our top priority and we strive for 100% satisfaction,

we would appreciate your feedback on the product. Please contact us if you have any questions regarding the product.

Our professional support team is always ready to answer your enquiries and provide assistance.

MS8302F

Page 2: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

1 2

1. GENERAL SPECIFICATIONS

MS8302F is a stable, safe, reliable compact digital handheld 6000 count auto-ranging multimeter. This meter can measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, temperature, diodes and continuity. This meter is ideal for many situations, whether you're a professional or causal user.

• Safety Rating: CAT III 600V; pollution degree: II

• Operating Altitude: 2000m

• Relative Humidity: 75% max operating

• Operating Temperature: 0°C~40°C/32°F~104°F (<80% RH)

• Storage Temperature: -10°C~60°C/14°F~140°F (<70% RH)

• Accuracy Temperature: -18°C~28°C/64°F~82°F (<80% RH)

• Temperature Coefficient: 0.1x(specified accuracy)/°C (<18°C or >28°C)

• Sampling Frequency: approx. 3 times/sec.

• Fuse Protection: µA/mA input: FF 600mA H 600V

10A input: FF 10A H 600V

• DC/AC Voltage: 600V

• DC/AC Current: 10A

• Resistance: 60MΩ

• Capacitance: 60mF

• Frequency: 10MHz

• Duty cycle: 1%~99%

• Diodes: 3.2V DC

• Continuity: <50Ω

• Temperature: -20°C~1000°C/-4°F~1832°F

• LCD Display: 3 ¾ digit display (6000 counts)

• Product Supply: 9V battery

• Product Size: 150mm×74mm×48mm / 6.3"×2.9"×1.9"

• Product Weight: 482g / 1.06lb

• Safety Standards: IEC61010-1

• Pollution Degree: 2

• Accuracy: ±(of reading + # of least significant digits)

2. WARNINGS

Check the meter before use to make sure there was no damage during

transit.

Check that the insulation on the test leads is not damaged and/or wires

are not exposed.

If any faults or abnormalities are observed, the meter should not be used

and should be checked out prior to use.

Never exceed the protection limit values indicated in specifications for

each range of measurement.

Always be careful when working voltages above 60V DC or 30V AC rms,

keep fingers behind the probe barrier while measuring.

Make sure the rotary switch is in the correct position before measurement.

Never use the meter in an environment with explosive gas, vapor or dust.

Always keep fingers behind probe barriers when making measurements.

When connecting test leads to a circuit, connect the black test lead first,

then the red lead. Disconnect in the opposite order.

Turn off power and discharge all capacitors first before measuring

resistance, continuity or diodes.

Failure to follow safety guidelines could compromise the safety features

of this meter.

Do not use the meter without the battery cover in place.

Replace the batteries as soon as the low battery symbol “ ” to avoid

false reading that could lead to electric shock and injury.

Remove test leads from all circuits before opening the battery cover.

To avoid electric shock and injury or damage to the meter, observe the

following safety methods:

Page 3: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

4

3. SAFETY SYMBOLS1.LCD Display

4.Frequency/Duty Cycle Button (Hz/%)

In AC voltage/current modes, press “Hz%” and the display will show the

frequency measurement. Press the button again to switch to duty cycle.

Press the button a third time to return to normal display.

2.Hold/Backlight Button

Press “ ” to hold the current reading on the display. Press the button

again to release the hold Hold “ ” to turn on the backlight.

Hold the button again to manually turn off the backlight.

3.Function Switch Button

Press “FUNC” to switch between functions or between AC/DC current.

/

, %” .

.

5.

6.Rotary Switch

7.Input Jack (all measurements; current below 600mA)

8.A Jack (current measurements between 600mA-10A only)

9.Common Jack (all measurements)

In Hz duty cycle

mode press the“Hz botton and the display will show the duty cycle

Press the button again to switch to the frequency measurement

NCV Button

Press the “NCV” button down in any mode and the meter will activate the

non-contact voltage detection. Hold the meter up to a voltage source and

the buzzer will sound and the NCV indicator will light up if voltage is

detected. Release the “NCV” button to stop NCV detection.

Important safety information

AC(alternating current)

DC(direct current)

DC/AC Voltage or Current

Double insulation protection

Fuse

Compliance with EU regulations

Ground

4. FEATURE DETAILS

3

5

4

3

2

6

8

7

9

1

/

F

6

Page 4: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

2

1

6 7 9 8

4

5

3

5. DISPLAY FUNCTION INSTRUCTIONS

3

2

5

7

6

8

Direct Current

Alternating Current

Negative DC Value

Auto Power Off

Data Hold

Auto Range Active

Diode Test

9 Continuity Test

6. ROTARY SWITCH FUNCTION INSTRUCTIONS

4

10

Low Battery

13 Main Display

10

10

11

11

12

12

12

Duty Cycle Mode

Temperature in Celsius

Temperature in Fahrenheit

Resistance

Frequency

Capacitance

DC/AC Current

DC/AC Voltage

2. AC Voltage:<600V

6

3.1 DC Current (large):<10A

5

1. DC Voltage:<600V

1

4 5 6 7 8 9

2

3

1

10

11

12

13

6

6

6

/

F

/

F

V

/

F

Page 5: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

7

AC Current (large):<10A3.2

4.1 DC Current (Middle):<600mA 6.2 Continuity:<50Ω

6.1 Resistance:<60MΩ

6.3 Diode Test:<3V

7. Capacitance: <60mF

8. Temperature: -20°C~1000°C/-4°F~1832°F

AC 4.2 Current (Middle):<600mA

AC 5.2 Current (Small):<6000µA

5.1 DC Current (Small):<6000µA

6

6

/

F

/

F

/

F

/

F

/

F

/

F

/

F

/

F

/

F

/

F

6

6

6

6

6

6

8

6

6

Page 6: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

9

Frequency:<10MHZ9.1

6

/

F

6

9 Duty Cycle:<99%.2

11. Non-Contact Voltage Detector NCV

/

F /

F

/

F

7. ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range Resolution Accuracy

600mV 0.1mV

±(0.5% of reading +2 digits)6V

60V

600V

0.001V

0.01V

0.1V

• Input impedance: 10MΩ• Max. input voltage: 600V rms

AC Voltage Measurement

Range Resolution Accuracy

600mV 0.1mV

±(1.0% of reading +5 digits)6V

60V

600V

0.001V

0.01V

0.1V

• Input impedance: 10MΩ• Max. input voltage: 600V rms• Frequency response: 40~400Hz, calibrated to rms of sine wave (average response)

10

/

F

600V 1V ±(0.7% of reading +2 digits)

600V 1V ±(1.0% of reading +10 digits)

Page 7: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

11 12

AC MeasurementCurrent

Range Resolution Accuracy

600 Aµ 0.1µA

±(1.2% of reading +5 digits)6000µA

60mA

600mA

1µA

0.01µA

0.1µA

• Overload protection: µA/mA input: Fuse(FF 600mA H 600V) 10A input: Fuse (FF 10A H 600V)• Frequency response: 40~400Hz, calibrated to rms of sine wave (average response)• Max. input current: µA/mA input: 600mA rms 10A input: 10A rms

10A 10mA ±(2.5% of reading +10 digits)

Resistance Measurement

Range Resolution Accuracy

600Ω 0.1Ω

±(0.8% of reading +5 digits)

6kΩ

60kΩ

600kΩ

0.001kΩ

0.01kΩ

0.1kΩ

• Max. input voltage: 600V rms

6MΩ 0.001MΩ

60MΩ 0.01MΩ

Continuity Test

Overload Protection Open Circuit Voltage

600V RMS Appx. 1.0V DC

• Max. input voltage: 600V rms

Diode Test

Overload Protection Open Circuit Voltage

600V RMS Appx. 3.2V DC

• Max. input voltage: 600V rms

Test Current

Appx. 1mA

±(2.0% of reading +5 digits)

Capacitance Measurement

Range Resolution Accuracy

1nF 0.001nF ±(4.0% of reading +10 digits)

10nF

100nF

1µF

0.01nF

0.1nF

1nF

10µF 10nF

100µF

1mF

10mF

100nF

1µF

10µF

100mF 10µF

±(3.0% of reading +10 digits)

±(4.0% of reading +10 digits)

DC Current Measurement

Range Resolution Accuracy

600µA 0.1µA

±(1.0% of reading +5 digits)6000µA

60mA

600mA

1µA

0.01µA

0.1µA

• Overload protection: µA/mA input: Fuse(FF 600mA H 600V) 10A input: Fuse (FF 10A H 600V)• Max. input current: µA/mA input: 600mA rms 10A input: 10A rms

10A 10mA ±(2.0% of reading +10 digits)

Page 8: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

13 14

Duty Cycle

• In current mode:

Signal input range: µA: ≥60µA rms mA: ≥6mA rms A: ≥0.6A rms

(current input will increase as frequency increases) Max. input current: 10A rms• In voltage mode:

Signal input range: ≥0.6V AC rms (voltage input will increase as frequency increases) Input impedance: 10MΩ Max. input voltage: 600V rms

• Overload protection: Fuse (F600mA/600V)

Range Resolution Accuracy

0 1%~99.9. % 0.1% ±3.0%

Temperature Measurement

Range Resolution Accuracy

-20°C~1000°C 1°C ±(2.0% of reading +2 digits)

-4°F~1832°F 1°F

Frequency ( ) Hz

Range Resolution Accuracy

9.999Hz 0.001Hz

±(1.5% of reading +5 digits)

99.99Hz

999.9Hz

0.01Hz

0.1Hz

• Signal input range:≥2V AC rms(voltage input will increase as

frequency increases)• Max. input voltage: 600V rms

9.999kHz 0.001kHz

99.99KHZ

999.9KHZ

0.01kHZ

0.1KHZ

9.999MHZ 0.001MHZ

±(2.0% of reading +4 digits)

Frequency (AC current)

Range Resolution Accuracy

99.99Hz 0.01Hz±(1.5% of reading +5 digits)

999.9Hz

>1kHz

0.1Hz

0.001kHz Reference only

• Signal input range: µA: ≥60µA rms mA: ≥6mA rms A: ≥0.6A rms

(current input will increase as frequency increases)• Max. input current: 10A rms

• ≥2V

Signal input range: AC rms(voltage input will increase as

frequency increases)Max. input voltage: 600V rms

Frequency ( ) %

Range Resolution Accuracy

1 – 99% 0.1% ± 2.0%

• Max. input voltage: 600V rms

Frequency cont. (AC voltage) ( )

Range Resolution Accuracy

99.99Hz 0.01Hz

±(1.5% of reading +5 digits)999.9Hz

>10kHz

0.1Hz

0.01kHz Reference only

• Signal input range: ≥0.2V AC rms

(voltage input will increase as frequency increases)• Input impedance: 10MΩ• Max. input voltage: 600V rms

9.999kHz 0.001kHz

Page 9: DIGITAL MULTIMETER - Mastechturkiye.commastechturkiye.com/wp-content/uploads/2016/07/MS8302F.pdfDIGITAL MULTIMETER CAT.III 600V SERVICE 00-05-3768 Thank you for purchasing our product!

15 16

9. CLEANING

WARNINGS To prevent injury or damage to the meter, do not allow moisture

inside the casing. Before opening the battery cover/case, disconnect test leads from all circuits.

Clean the meter regularly with a damp cloth and a small amount of

detergent; do not use abrasives or solvents. Dirty/wet input jacks can

affect readings.

To clean input jacks:

1. Turn off the meter and remove test leads.

2. Brush off any dirt or contaminants from the input jacks.

3. Use a cotton swab with a cleaner/lubricant (i.e. WD40)

to clean the input jack.

4. Use a new swab on each jack to prevent cross contamination.

11. REPLACING THE FUSES

WARNINGS To prevent injury or damage to the meter,

turn off power to the meter and disconnect test leads from input before opening case.

To replace the fuses:

1. Turn off power to the meter.

2. Remove test leads from input jacks.

Remove the 6 screws on the back case

and remove back case from meter.

4. Replace blown fuse(s) with a new fuse.

5. Replace back cover and secure to meter.

3.

10. REPLACING THE BATTERIES

To replace the batteries:

1. Turn off power to the meter.

2. Remove test leads from input jacks.

3. Loosen the screw on the battery cover and remove cover from meter.

4. Replace used batteries with new batteries.

5. Replace battery cover and secure to meter.

WARNINGS To avoid false reading that could lead to injury or damage to the meter, replace the batteries as soon as the “ ” symbol appears. Turn off the meter and remove the test leads before opening the

battery cover to avoid injury or damage to the meter.

8. MAINTENANCE

This section provides basic maintenance principles, including replacing batteries and fuses. Do not attempt to repair or perform any maintenance on the meter not included in the section below unless you are qualified personnel.

12. DISPOSAL / RECYCLE

Caution: This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.