digital facility data transfer approach from bim model to ...essay.utwente.nl/76652/1/seyadi, aulia...

142
FACULTY OF ENGINEERING TECHNOLOGY DEPARTMENT OF CONSTRUCTION MANAGEMENT AND ENGINEERING Digital Facility Data Transfer Approach from BIM Model to Maintenance Management Software for Existing Building Case Study Facility Management University of Twente Msc. Thesis Report Aulia Rahman Setyadi

Upload: others

Post on 19-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

FACULTY OF ENGINEERING TECHNOLOGY

DEPARTMENT OF CONSTRUCTION MANAGEMENT AND ENGINEERING

Digital Facility Data Transfer Approach from

BIM Model to Maintenance Management

Software for Existing Building

Case Study Facility Management University of Twente

Msc. Thesis Report

Aulia Rahman Setyadi

Page 2: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

Digital Facility Data Transfer Approach from

BIM Model to Maintenance Management

Software for Existing Building

Case Study Facility Management University of Twente

Msc. Thesis Report

Author:

Aulia Rahman Setyadi

s1790242

[email protected]

[email protected]

Supervision Committee:

Dr. Andreas Hartmann (Chair)

Dr. Farid Vahdatikhaki (Supervisor)

Dr. Ir. Léon olde Scholtenhuis (Supervisor)

Department of Construction Management and Engineering

Faculty of Engineering Technology

University of Twente

Page 3: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

i

ABSTRACT

As a building construction project phase is completed, as-built building data are then submitted to the

owner or the Facility Management (FM) service. The FM will utilize this data for building Operation

and Maintenance (O&M) purpose. Currently, the facility data transfer process, i.e., the mechanism for

transferring facilities data from the digital construction software to the O&M systems, is mostly paper-

based, which makes it time-consuming and error-prone. Building Information Modeling (BIM) can

contribute to the building O&M phases by providing an integrated building data storage and

transferring information timely and accurately through the integration between BIM model with the

maintenance system. Technical issues become barriers for facility managers in integrating BIM with

their FM system. Previous studies mostly discuss how to solve the facility digital data transfer process

for a new construction. Few studies however addressed the transfer of digital representation of

existing buildings. This study develops a BIM based data transfer approach for existing digital buildings

representation to existing FM maintenance management software. The digital facility data transfer

approach proposed in this study consist of a process of collecting and restructuring building data from

BIM model and then transfer it to the maintenance management software. The proposed approach

was implemented during a case study of the High Pressure Laboratory building at University of

Twente. The result of this study demonstrates how the process of facility digital data are processed

and transferred from BIM model to a maintenance management software. The potential benefit,

obstacle and the actions to be considered are also discussed in order to improve the BIM based data

transfer process from BIM model to maintenance management software.

Page 4: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

ii

ACKNOWLEDGEMENT

First and foremost, I would like to thank God Almighty for giving me the strength, knowledge, ability

and opportunity to undertake this research study and to persevere and complete. Without his

blessings, this achievement would not have been possible.

I would like to thank the thesis advisor, Dr. Farid Vahdatikhaki, Dr. Ir. Léon olde Scholtenhuis and the

chair of research committee Dr. Andreas Hartmann for their understanding, patient guidance,

encouragement, and useful critiques of this research project. They always opened their door

whenever I ran into a trouble spot or had a question about my research or writing. A special

acknowledgement to Lembaga Pengelola Dana Pendidikan (LPDP) who provides financial support for

my study in University of Twente.

I would also like to thank the Maintenance Manager of Facilitair Bedrijf University of Twente, Mr. Ray

Klumpert for his generosity to provide essential information and for his support to this research. I

would also like to acknowledge Mr. Arjen Koster from Prognotice B.V who has kindly shared his

knowledge about the Prognotice.

Last but not the least, I would also like to thank my parents, family, and all of my friends for the never-

ending support during my study.

Page 5: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

iii

Table of Contents

ABSTRACT .............................................................................................................................................. i

ACKNOWLEDGEMENT ........................................................................................................................... ii

Table of Figures ..................................................................................................................................... v

Table of Tables ...................................................................................................................................... vi

1. Introduction .................................................................................................................................. 7

1.1. Problem Statement ............................................................................................................... 8

1.2. Problem at Facility Management of University of Twente .................................................. 11

1.3. Research Objective and Questions ...................................................................................... 11

2. Literature Study .......................................................................................................................... 13

2.2. Conventional Building Data Transfer Method ..................................................................... 14

2.3. Operations and Maintenance Phase Data ........................................................................... 14

2.4. BIM Data Transfer ............................................................................................................... 15

2.5. Facility Digital Data Transfer Method .................................................................................. 16

3. Research Methodology ............................................................................................................... 20

4. Digital Facility Data Analysis ........................................................................................................ 23

4.1. FM UT Maintenance Data Management ............................................................................. 23

4.2. Revit Model and Prognotice Data Analysis.......................................................................... 24

4.3. Identify Required Information for Building Operational & Maintenance ............................ 32

4.4. Identify Data Format ........................................................................................................... 33

4.5. Summary ............................................................................................................................. 33

5. Facility Digital Data Transfer Workflow ....................................................................................... 35

6. Case Study and Implementation ................................................................................................. 38

6.1. Collect Building Component Data from Revit Model .......................................................... 38

6.2. Restructure Database.......................................................................................................... 41

6.3. Import Data to Prognotice .................................................................................................. 45

6.4. Building Component Data Import Result ............................................................................ 46

6.5. Result Validation ................................................................................................................. 47

7. Discussion and Conclusion .......................................................................................................... 49

7.1. Discussion ........................................................................................................................... 49

7.2. Conclusion ........................................................................................................................... 52

References .......................................................................................................................................... 53

APPENDIX A ........................................................................................................................................ 55

Page 6: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

iv

APPENDIX B......................................................................................................................................... 57

APPENDIX C ......................................................................................................................................... 61

APPENDIX D ........................................................................................................................................ 64

APPENDIX E ......................................................................................................................................... 96

Page 7: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

v

Table of Figures Figure 1-1 Graphics and attribute data changes over the facility lifecycle............................................ 9

Figure 2-1 Major facility lifecycle phases ............................................................................................ 14

Figure 4-1 BIM authoring software and maintenance management software used by FM UT .......... 24

Figure 4-2 Prognotice data hierarchy .................................................................................................. 25

Figure 4-3 Component data relationship ............................................................................................ 26

Figure 4-4 Object hierarchy in Revit model ......................................................................................... 27

Figure 4-5 Data inheritance in Revit model......................................................................................... 28

Figure 4-6 Relationship type between component in Revit model and Prognotice ............................ 29

Figure 4-7 Relationship type between component in Revit model and Prognotice (2) ....................... 30

Figure 4-8 Data mapping possibility between Revit model and Prognotice ........................................ 31

Figure 5-1 Proposed BIM Based building data transfer workflow. ...................................................... 35

Figure 6-1 Tools or software used in the case study ........................................................................... 38

Figure 6-2 Element filtering ................................................................................................................ 40

Figure 6-3 Get elements parameter value nodes ................................................................................ 40

Figure 6-4 List management and export nodes................................................................................... 41

Figure 6-5 Dynamo algorithm for NLSFB code restructuring .............................................................. 42

Figure 6-6 Key element, element, and sub-element code in Prognotice ............................................ 43

Figure 6-7 Dynamo algorithm to generate key element and element code ....................................... 43

Figure 6-8 Element grouping and quantity counting in Dynamo ........................................................ 44

Figure 6-9 Prognotice data import ...................................................................................................... 45

Figure 6-10 Building data transfer result in Prognotice ...................................................................... 46

Figure 6-11 Component attributes data in Prognotice ....................................................................... 47

Page 8: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

vi

Table of Tables Table 2-2 Digital Facility Data Transfer Approaches............................................................................ 16

Table 4-1 Building Component Classification List ............................................................................... 32

Table 4-2 Component Property in Prognotice .................................................................................... 33

Table 6-1 Element Properties to be Exported ..................................................................................... 39

Table 6-2 NLSFB Code Naming Before and After Restructured ........................................................... 42

Table 6-3 Structured Building Component Data ................................................................................. 44

Table 6-4 Building Component Data Extracted from Prognotice ........................................................ 48

Table 7-1 Conventional vs BIM based building data transfer method ................................................ 49

Page 9: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

7

1. Introduction

The Operation and Maintenance (O&M) phase constitutes the greatest part of a building lifecycle. The

costs involved in this phase could take up to 60% of the total project costs (Teicholz & Fellow, 2004).

Based on this, improving the efficiency during the O&M phase could reduce overall building lifecycle

costs. One important element of the operation and maintenance stage is the availability and access

to the building data. Currently, the facility data transfer process, i.e., the mechanism for transferring

facilities data from the construction phase to the O&M phase, is mostly paper-based, which makes it

time-consuming and error-prone.

The emergence of Building Information Modeling (BIM) in the construction industry potentially brings

benefits not merely to the design and construction phases, but also to the O&M phases. BIM can be

defined as both a process and technical tool that can support the entire lifecycle of project by enabling

better communication and management of projects’ data for all the involved stakeholders. Although

BIM models are currently developed mainly for design and construction phases, they can also provide

useful support for facilities managers during O&M stages. BIM models can provide digital descriptions

of facilities objects (such as walls, ceilings, services, doors etc.), their relations and properties. Such an

extended application of BIM, can contribute to the building operation and maintenance phases by

enabling efficient query of key information, transferring information timely and accurately, and

updating data conveniently through the integration with the Facility Management (FM) system (Lu et

al. 2018).

Despite mentioned benefits of using the information model for requesting, exchanging, and updating

building operation data, current practices show that the potential of BIM in O&M stage is not well

exploited yet by facility managers. Both process and technical issue are barriers for facility managers

in integrating BIM with their maintenance management system. The implementation of BIM for FM

still focusses on new building project rather than on existing building (Volk et.al, 2014). Hence,

organizations that already utilize specific maintenance management system to manage their facility

for a long period are facing problems to use digital building data from BIM model for the building

maintenance purposes.

The needs to develop a specific digital facility data transfer approach for existing building will be the

main focus of this research. The emphasized of the research is to develop a digital facility data transfer

approach from BIM model to maintenance management software for the organizations that have

Page 10: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

8

been using specific maintenance management system to manage existing buildings with specific

condition and maintenance management software.

This report starts with the introduction section in chapter 1 which also discuss the problem raised and

the research objective to solve it. In the Chapter 2, the literature study within this topic is discussed

continued with the research methodology performed in this study which can be found in Chapter 3.

Chapter 4 explains the data analysis in developing the BIM based building data transfer approach. The

proposed workflow is then discussed in Chapter 5. This proposed workflow or approach was then

implemented in a case study which is discussed in Chapter 6. This report is closed by the discussion

and conclusion in Chapter 7.

1.1. Problem Statement

O&M phase is the phase after the facility has been completed and is ready for use. The start of this

phase is initiated by the handover process of all building data from construction phase to the owner.

The facility manager is responsible for activities taking place during the O&M phase. According to IFMA

(2013), Facility Management (FM) is a profession that encompasses multiple disciplines to ensure

functionality of the built environment by integrating people, place, process and technology.

Facility manager uses asset data – such as the condition of various objects in a building- to plan and

execute maintenance tasks. Those documents are transferred as the project progresses from the

construction to the O&M phase. Such documents can be in distinct formats. In many cases, the

documentation of the buildings comprises paper files or drawings (Teicholz, 2013). However, the use

of paper-based document in building data transfer processes are considered to be inefficient. Paper

documents are normally handed over months after the construction is finished, and even after the

building is already in use (Teicholz, 2013). Therefore facility managers are searching for a new

technology and process to face the challenge of collecting, categorizing, visualizing and updating the

information for operation and maintenance purpose (Ibrahim et al., 2016)

On the other hand, BIM has emerged as a new concept that combines technology and process for the

generation and management of digital images of physical and functional characteristics of a building.

This concept has been well developed in the Architecture Engineering and Construction (AEC) industry.

BIM can provide a visually and dimensionally accurate three-dimensional digital representation of a

building (Teicholz, 2013). It provides a shared knowledge resource for information about a facility

forming a reliable basis for decisions during its life-cycle (NIBMS-US, 2018).

BIM consists of certain amount of both graphics and nongraphic/attribute data of a facility. Graphic

data are visual and dimensional representative of the building while the attribute data describe the

Page 11: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

9

detailed profile of building components. As the construction project progress from the

design/construction phase to O&M phase, the need of graphical and nongraphic or attribute data is

changing. The amount of attribute data is growing as the project proceed to the next phase as shown

in the Figure 1-1. Greater amount of attribute data are utilized in the O&M phase than in the earlier

phase.

Figure 1-1 Graphics and attribute data changes over the facility lifecycle. source: (Teicholz P. , 2013)

Once the design phase is completed, facility attributes data from BIM model can be applied for the

multifaceted facility management applications such as maintenance planning activities, space

management, asset tracking, design information for future projects, performance tracking and other

operation and maintenance tasks (DSF, 2011).

An effective way to benefit from BIM data would be to digitally transfer data from the construction to

O&M phase, and thus replace the conventional data transfer approach. In conventional approach

normally building data are populated manually to the maintenance management software (Teicholz,

2013). The key benefit of integrating BIM with maintenance management system is thus that data no

longer needs to be modelled twice (i.e. in BIM software andm maintenance management software).

BIM adoption in the construction industry is currently accelerating rapidly. However, the focus is still

very strongly on the design and construction processes (Kiviniemi & Codinhoto, 2014). Consequently,

there is a technological gap between design/construction and O&M phases because of which

interoperability problems arise. Consequently, although each object in the BIM model can be linked

to maintenance management systems (Beatty et.al 2013), connection is not that simple to achieve in

practice. Facility Managers are still experiencing problem in adopting building digital data transfer

approach. BIM authoring software and maintenance management software are technically different

systems, hence building data is not easy to be transferred directly from BIM authoring software to

maintenance management software.

Page 12: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

10

Prior studies also show that the main barriers that might be faced include interoperability issues

(Naghshbandi, 2016). In order to build better connection between BIM model and FM system, there

is a need of interoperability between systems (Teicholz, 2013). Efforts to overcome the

interoperability and data exchange problem have been done by numerous institutions that developed

several building data transfer approaches. Teicholz (2013) identified four common approaches for

data transfer from the construction phase systems to FM systems:

1. Using a manually developed spreadsheet to capture facility data needed for FM and importing

it to FM systems;

2. Using open standard file formats to capture facility data from BIM model and then importing

it to FM systems;

3. Using middleware to capture facility data from BIM model and importing this to FM systems;

4. Directly integrating BIM models and FM system.

However, from the developed building data transfer approaches, there is no consensus on which

approach suits what maintenance management systems. case studies compiled by Teicholz (2013)

shows that different maintenance management systems require different data transfer approaches

depending on the condition of the organizations and their maintenance management system settings.

Furthermore, Dias and Ergan (2016) identify the need for customized facility information in the BIM

model for each operator. Each operator requires a specific set of data to complete their maintenance

tasks. It is difficult to make a standard dataset that would be usable for all the facility management.

Moreover, according to Teicholz (2013), each organization requires different building information to

be integrated to their maintenance management system.

Recent studies have started to find the possible integration method of BIM and maintenance

management software, but the main focus is still on new project instead of for existing building

(Ravetz, 2008). Case studies that was performed for instance, mostly discussed the digital facility data

transfer from BIM model to maintenance management software for new projects. Even tough, there

are more existing buildings where building data are managed in conventional ways and the data are

often incomplete or obsolete (Carbonari et.al, 2015). Hence, organizations that already utilize specific

maintenance management system to manage their existing building for a long period are facing

problems to integrate their maintenance management software with BIM authoring software.

It can be concluded that problem in digital facility data transfer from BIM model to maintenance

management softare is still experienced by facility managers. The problem arises due to different

maintenance management systems used by different FM which require specific building data set and

Page 13: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

11

digital building data transfer approach. There is still a lack of research that discuss digital data transfer

method from BIM to maintenance management software for existing buildings.

The needs to develop a BIM based data transfer approach for existing building will be the main focus

of this research. The emphasized of the research is to develop a BIM based data transfer approach for

the organizations that have been using specific maintenance management system to manage existing

buildings for a certain period with specific condition and maintenance management system setting.

1.2. Problem at Facility Management of University of Twente

Facility Management of University of Twente (FM UT) is a department in the university which has a

responsibility to manage facilities owned by University of Twente. One of their responsibility is to

manage the maintenance plan of buildings within the university area. Therefore, they are also

responsible to transfer building data to their maintenance management system. At the moment,

building information are stored in different formats such as paper documents, 2D drawings, dwg files,

and pdf files which is actually received from a conventional building data handover process. However,

FM UT is trying to reduce the dependency on paper-based documents and has a plan to replace them

with BIM model.

More importantly, FM UT is experiencing a difficulty to find the best approach to connect BIM model

and the maintenance management software to transfer data between the two system. In this study,

the researcher, therefore, investigated a proper approach to transfer digital facility data from BIM-

model to maintenance management software which fit the organization’s workflow and maintenance

management system.

1.3. Research Objective and Questions

A research is necessary in order to clarify some practical challenges of BIM based data transfer

approach for the existing building. A specific building digital data transfer approach then needs to be

developed. Therefore, the main objective of this research is to develop a digital facility data transfer

approach from BIM model to maintenance management software, which emphasized to the practice

for the organization which has been managed existing building with their maintenance management

software.

Building data transfer processes from BIM model to maintenance management software of the Facility

Management at University of Twente will be taken as a case study for this research. In order to support

the research objectives in collecting and analyzing the information, the following research questions

are specified:

Page 14: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

12

i. What types of information are used in the current FM practices/systems at UT?

a. How does the current workflow input data from as-built information to maintenance

management system?

b. What are the maintenance management tools used at Facility Managment of the

University of Twente?

c. What are the necessary building information and data for the maintenance of facility?

d. What are data formats to be imported to maintenance management software?

ii. How can the required maintenance information be generated from the BIM model?

a. Which facility information is provided in the BIM model?

b. Which data formats can BIM authoring software export?

iii. How to connect BIM model and UT FM system for the building digital data transfer purpose?

a. What are the available digital data transfer methodologies?

b. How can the building data transfer methodologies be applied to the existing maintenance

management software?

c. What are the required workflows for building data transfer methods?

d. What are the technical requirements to conduct the building data transfer process?

e. What adjustments need to be made both to the BIM model and to the maintenance

management system to streamline the integration?

These main questions then will be answered by observing some information from Facility

Management of the University of Twente as well as practical implementation of BIM based data

transfer method to a case study.

Page 15: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

13

2. Literature Study

2.1. Facility Information for Facility Management

The most essential element in running the facility management is the access to the facility information.

In order to make a decision about what action should be conducted to the facility, the facility manager

needs to have quick access to the real time facility condition or performance. Therefore, he ought to

deeply understand about the facility he is managing including all the system working in it, the

components which are installed, the location where they are mounted, their specification, etc. This

information can be endless and very large in quantity especially for a complex building. Therefore, as

a facility manager, he has to understand which information has to be included in the database and

which has to be excluded.

Decision to include certain facility information is equally important as the decision to exclude

unnecessary facility information. A clear definition and analysis of what kind of information should be

captured during the design and construction phase and selecting which one to be included in

operation and maintenance phase become essential. Deciding which information has to be captured

during the design and construction phase will avoid the facility management from missing the

important facility information. Facility information generated in design-construction phase might

contain information for instance regarding the construction phase which is not to be involved in

operation and maintenance phase, this kind of information which has to be excepted from the facility

management system.

In order to effectively perform his task, facility manager has to get access to obtain the facility

information in time. Having the right information at the right time enables facility manager to make

decision quickly. However, in operating one or more buildings, vast amount of data in different form

has to be managed appropriately. Accordingly, a software that is able to assist facility manager

especially in managing massive maintenance data is required such as computerize maintenance

management software (CMMS).

According to Sapp (2016) CMMS is a software that is used to schedule and record operation and

preventive maintenance activities associated with facility equipment. CMMS is also used to maintain

information about organization assets including facilities with all of the components. As it appears on

its name, CMMS is mainly used for maintenance purpose. CMMS keeps track of maintenance plan or

activity, for example it manages the information about how often a component has to undergo a

repair or checkup, which component has to be replaced, etc.

Page 16: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

14

2.2. Conventional Building Data Transfer Method

During the building or facility lifecycle, the facility data are being transferred through a handover

mechanism multiple time. The Capital Facilities Information Handover Guide (CFIHG) describes six

major phases in the building life cycle; Planning and Programming, Design, Construction,

Commissioning, Operations and Maintenance, and Disposal. In a traditional contract, these phases are

seen as a sequential process with a defined facility data handover points between each phase (Figure

2-1) The smaller arrows in the Figure 2-1 show the information flow from or to different phases.

Figure 2-1 Major facility lifecycle phases (source CFIHG part1)

Traditionally, these phases have been seen as sequential, with defined handover points between

phases and additional information flows (smaller arrows in Figure 2-1)

The information about completed facility utilized by the FM are mostly obtained from the

design/construction phase trough a handover mechanism. The facility data are not collected at once,

large portion of facility data to support FM are created throughout the design and construction

processes (Thabet & Lucas, 2017), information creation begins at the commencement of a project and

continues throughout the facility lifecycle (DSF, 2011).

2.3. Operations and Maintenance Phase Data

The operation and maintenance phase generates its own information base, which can be used to

improve facility performance and informs decisions about expanding or disposing of the facility. This

information includes production or occupancy levels, service requests, maintenance schedules,

inspection reports, work orders, equipment downtime, operating costs and maintenance costs.

Page 17: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

15

Aforementioned information is submitted in the form of documents in different format, for instance

digital files or paper documents. The digital files are usually visual or graphic representation of the

building which are delivered in 2D drawing for instance in CAD files format. The digital drawings

however only contain building graphic information. In order to complement graphic data, other

information regarding facility component’s attribute data are provided in paper documents or

scanned paper documents. As the result, most of the documents handed over to facilities managers

by contractors are still paper based (Rebekka Volk & Schultmann, 2013) especially for documents used

by the operator of existing building (Teicholz, 2013).

Conventional paper-based data transfer method potentially results in poorly organized facility data

(DSF, 2011). Consequently, paper documents are often lost, cannot be easily updated, and require a

large amount of space to store (East, 2010). Moreover, for the FM it requires a lot of man-hours to

recreate incomplete and inaccurate information (Carbonari et al. 2015) and then manually populate

them into maintenance management system. Therefore, facility managers need a new technology and

process to face the challenge of collecting, categorizing, visualizing and updating the facility

information for operation and maintenance purpose (Ibrahim et al. 2016). Facility managers have to

improve their approach in managing the facility information to increase the efficiency of building data

handover process (Fallon & Palmer, 2007).

2.4. BIM Data Transfer

BIM is emerging as a methodology for generating, exchanging and managing a constructed facility’s

data throughout its life cycle (Ibrahim et al. 2016). BIM is claimed to be able to provide the integration

of data systems during the building’s life cycle (Carbonari et al. 2015). Thus, there is an opportunity

for facilities managers to improve the current FM practice by extending the BIM model utilization into

the operation period. BIM models can be used to support FM in O&M phase (McArthur, 2015). There

are several potential benefits of using BIM during operations and maintenance that confirm the

importance of extending BIM to facilities management practice (Carbonari et al. 2015).

2.4.1. The BIM Model

One product of BIM implementation in AEC industry is computer generated building model or is

commonly called BIM model. BIM model can have different meanings, different users have their own

description of what a BIM model is. According to Teicholz (2013) a BIM model is not merely a 3D

representation of a building, it is also structured information base of non-graphic data that provide

detail information about building components. Moreover, BIM model has been referred to n-

Page 18: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

16

dimensional computer-generated model which can be used to simulate the planning, design

construction, and operation of a building.

In contrast with the generation of 2D drawing where each drawing is independent of other drawings,

in a BIM model every single view is connected to other views. In 2D drawing for instance, a change to

one drawing might cause revisions to other drawings which needs to be done separately. In a BIM

model change only needs to be done once and it will influence all data linked to that part.

Furthermore, in a BIM model, all components of the model or drawings can be enriched with their

detail data for example capacity, size, and even their supplier etc.

2.4.2. BIM for Digital Facility Data Transfer to Maintenance Management System

A BIM model contains facility data that can be used through the building lifecycle including the O&M

phase. BIM has a critical role to perform as a contributor to FM system; by supplying 3D geometry and

attribute data in a digital format that can streamline operations and maintenance over the long term

(Kensek, 2015; Teicholz, 2013). The BIM model describe the three-dimensional geometry, objects, and

attribute of the facility in a digital format (Teicholz, 2013).

Utilizing the building digital data instead of a paper-based documents will potentially provide many

benefits for FM especially for the data handover process. Building digital data from the

design/construction phase contained in BIM model can be transferred without having to re-enter it

manually to the FM system (Aziz et al. 2016). The building component data can be exported from BIM

model and then linked to the FM system (Kensek, 2015). BIM utilization in building data transfer

process differs from the conventional methods (Naghshbandi, 2016) which are mostly done manually

(Carbonari et al. 2015).

2.5. Digital Facility Data Transfer Method

In recent years, researchers have developed several digital data transfer approaches to overcome the

interoperability problem. Teicholz (2013) identified four common approaches for facility data transfer

from the construction phase to FM systems which is summarize in the Table 2-1.

Table 2-1 Digital Facility Data Transfer Approaches

Approach Method Advantages Drawbacks

Manual The building data from handover

documents are manually

transferred to FM system by

developing spreadsheet to

Some FM are already

familiar with this approach

Easy for small project

Time consuming, high cost

High error rate likelihood

Page 19: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

17

Approach Method Advantages Drawbacks

capture building data for FM and

then import it to FM system

Open standard Building data is transferred to FM

system by exporting them from

the BIM model into open data

format. This building data then is

imported into FM system

Exported data from BIM

model can be adjusted with

Maintenance management

software.

Better interoperability

Data might include redundant

data for FM.

Heavy weight file

Middleware Building data are transferred to

FM system by capturing them

from BIM model and export them

into FM system via middleware

Can be a bi-directional

integration,

Integrate the BIM data into

existing workflows without

the need to transfer large

amounts of existing data to

a new system

Complex process and the

implementation is fixed

during programing in

proprietary middleware

approach

Direct

Integration

Building data are directly

translated from BIM model to FM

system

A bi-directional integration,

FM manager able to

consistently update

information in both

systems.

At the moment, still limited

to specific Maintenance

management software.

Require time and money to

develop this method

Might require new FM

systems adoption

Manual data transfer is applied by entering the building information manually to Maintenance

management software or costumed spreadsheets by the facility manager. This practice is

implemented by FM which still depends on paper-based documents.

BIM-FM data transfer is also possible to be conducted by utilizing open standard format, for instance

Industry Foundation Classes (IFC) or Construction Operation Building Information Exchange (COBie).

The facility data is exported from BIM model into an open standard format and then imported to the

FM system. IFC is an open, vendor-neutral format for hosting the semantic information of building

objects, including geometry, associated properties, and relationships to facilitate cross-discipline

Page 20: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

18

coordination of building information models, including architecture, structural, and building services,

data sharing and exchange across IFC-compliant applications. IFC is an object-oriented database of

information that enables data sharing via ifcXML and aecXML. COBie is a non-proprietary data format

for the publication of a subset of BIM focused on delivering asset data as distinct from geometric

information (Hamil, 2017). COBie can also be defined as information exchange to deliver information

required at O&M phase.

The data transfer from BIM model to the FM system can also be done by utilizing a proprietary

middleware for data integration. Proprietary middleware is a computer software that is designed by

a certain company which provides services to software applications beyond those available from the

operating systems (Ibrahim, 2016). Model and data are captured from BIM model by the middleware

and then exported to the FM system after review and modifications in the middleware’s user interface

Direct proprietary exchange standards are based on direct translation from the internal data structure

from BIM model into the internal data structure of Maintenance management software. One method

for this direct link would be to develop a customized plug-in by using the program’s Application

Programming Interface (API). An API allows for a user to program specific interactions with the model’s

data that are not developed as out of the box functions for the program. The other method for a direct

link would be to utilize a Maintenance management software platform that has already developed the

link (Thabet & Lucas, 2017).

Aforementioned building data transfer approaches are compiled from several case studies. Different

data transfer method is developed to accommodate distinct organizational condition and settings. The

case studies are also a prove that there is no single digital facility data transfer approach that is fit with

all the maintenance management system. Although several study cases have been conducted, most

of them investigate digital data handover approach from BIM model to maintenance management

system for new construction projects. There are still few researches that study the BIM-based

handover approach for existing building and maintenance management system (Carbonari et al.

2015). Whereas, most FM that operate and manage existing buildings have already their own existing

guidelines and maintenance management system to handle the facilities information (Ibrahim et al.

2016).

Prior to determine which facility digital data transfer to be implemented, Thabet & Lucas (2017)

proposed three steps to be completed. These steps consist of deterimining the objective, conduct data

analysis, and define data format. The objective that has to be determined refer to the organization’s

rationale and goal in implementing digital facility data transfer from BIM model to maintenance

Page 21: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

19

management software. This step is then followed by analyzing the facility data to be transferred

includes its naming and other standards. The third step is to define the data format which the facility

data to be delivered and then transferred to maintenance management software.

Utilizing digital instead of paper-based facility data for operation and maintenance purpose potentially

give numerous benefits for FM to perform the operation and maintenance task. The digital facility

data for maintenance purposes can be collected from BIM model which has capability to provide the

digital reprentatives of a building. However, most of the BIM authoring software are not compatible

with the existing maintenance management software. This technical issue impedes the

implementation of digital facility data transfer from BIM model to maintenance management

software. Therefore, the work to be done by facility managers is to find a right approach to connect

BIM model to their maintenance management software so that digital facility data in BIM model can

be automatically transferred to the maintenance management software. Several case studies within

this topic have been conducted but the results are yet to solve all the problems. More practical

research that study the digital facility data transfer approach for organizations that already operate

buildings with their FM system is thus a necessity to answer the technical gap and the lack of the

practical guidelines or case study for this topic. The study should be able to develop the digital facility

data transfer method which fit with the FM‘s existing condition and maintenance software, which is

the main objective of this research.

Page 22: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

20

3. Research Methodology

3.1. Research Design

The study is started by a literature review, aimed at understanding the current gap and problems and

the theory or framework about BIM based handover approaches. The theoretical framework was also

generated from literature study such as research papers, books, and other documents sourced from

internet. The keywords used include BIM, facility management, facility data transfer and operation

and maintenance. The information obtained from this stage is used as a basis for rest of the research.

The required information to perform the research was then collected by first conducting interview

with the maintenance manager of FM UT to gather information about the way they manage their

maintenance task and how the current practice of building data transfer method in FM UT and also to

discuss about the problem faced and expectation in implementing BIM based data transfer method.

The second interview was held with one of the program developers in Prognotice B.V, a company

which develop a maintenance management software used by FM UT. An unstructured interview was

conducted to discuss the technical aspect of Prognotice. On the other hands, the BIM model and other

building and maintenance data are obtained from FM UT. The access to maintenance management

software used by FM UT is also received in order to learn how the software works.

The collected data was then analyzed. First, to identify FM UT organization’s condition and goal in

implementing digital facility data transfer from BIM model to their maintenance management

software. The objective of this stage is to obtain information about FM UT current practice and

expectation of digital facility data transfer implementation. Current state of FM UT practice including

organizational conditions for collection and registering the facility data and existing maintenance

management software are observed in this step. The existing issues and challenges with the current

data handover practices are also analyzed. To obtain this information, interview is arranged with the

Facility Manager of FM UT.

The output of this step was used as a basis for the development of the BIM-FM data handover

approach at the next stage. The organizational expectation of BIM-based data handover was used to

formulate the method for the BIM-FM data handover process.

Furthermore, the analysis on the technical aspect was also performed. How the building component

data are stored in both BIM model and mainteanance management software were analyzed and

compared. The goal is to find the appropriate approach to connect the data in BIM authoring softwarel

to maintenance management software. Moreover, the building data to be transferred from BIM

Page 23: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

21

model to maintenance management software were also identified. During this stage, the data sets

which are important for maintenance purposes are identified. It includes the parameter that should

be included in the BIM model. Transferring all of the data contained in BIM model will cause too much

redundant data in maintenance management software.

The analysis was proceeded by identifying data format. Data format refers to the maintenance

management software used by FM UT to store and manage facility information. Furthermore, data

standards, structure, and naming conventions of existing maintenance data owned by FM UT are also

analyzed. What data format and how data structure which compatible with maintenance

management system determines on which digital facility data transfer method must be applied.

The result of data analysis was used to develop the facility data transfer approach from BIM model to

maintenance management software. This is the stage to develop the digital facility data transfer

approach which is compatible with the provided BIM model and maintenance management software.

Multiple tools or program were used to process building data in BIM model and transfer them to

maintenance management software. The output of this stage is the hypothetical workflow to

implement digital facility data transfer from BIM model to the existing maintenance management

software.

In order to test the effectiveness of the digital facility data transfer workflow developed in this study,

this proposed workflow was implemented to a case study. By implementing the proposed digital

facility data transfer approach to a case study, the challenge and benefit experienced in the building

data transfer process can be identified. Moreover, the result of the process was evaluated for future

improvement. The result and finding of this process is then evaluated and analyzed which is also the

output of the study.

3.2. Research Boundaries and Limitations

There are several boundaries and limits set for this research:

a. The research only covers the development of building data transfer method from BIM model to

maintenance management software. The process of how the BIM model is generated is not

included in this study.

b. A single case study performed in this research makes the generalization of the conclusions of this

research difficult. The result of this study might be valid only for the BIM authoring software and

maintenance management software used by FM UT. However, the result can be used as

reference for other research or implementation conducted in similar circumstances.

Page 24: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

22

c. The building component data collected and transferred from BIM model to maintenance

management software might not contain the real data that is required by FM UT. The document

that govern which component data to be collected is still under discussion by the FM UT when

the research was conducted. The criteria of component data to be collected might influence the

way the building component data are collected and extracted from BIM model and also the final

result on what building component are finally transferred to maintenance management software.

Page 25: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

23

4. Digital Facility Data Analysis

As an initial step of the digital facility data transfer approach development, the current practice of FM

UT in managing the facility and maintenance data was analyzed. It includes the current facility data

transfer practice, the maintenance management software they are using and the current digital facility

data transfer practice. This information was obtained from interview with the Maintenance Manager

of FM UT. The question asked during the interview session can be found in APPENDIX A.

The next step, facility data in Revit model and Prognortice are analyzed and compared so that the

possible connection can be determined. Data in a BIM model and maintenance management software

that are going to be connected can vary in format, structure and content. It is important to make sure

that data sourced from different databases have been appropriately cleaned and standardized. This

step was then followed by identifying required information to be transferred from BIM model to

maintenance management software. The data format to be transferred was also identified

accordingly.

4.1. FM UT Maintenance Data Management

Building data are obtained from a contractor once the building project has been completed.

Technically, building data from design and construction phase is submitted by a contractor to facility

management in DVD and a paper. The data comprise the building design drawings and information

about all components of the building. Aside from paper documents, the building data is also received

in form of digital data. The documents stored in digital form consists of building drawings in CAD

format and building component attributes data documents in Ms. Word or PDF format. All the digital

building data are stored on a storage disk while paper documents are secured in a special

documentation storage room

In performing the building maintenance task, FM UT is leveraging a long-term maintenance

management software, Prognotice. Prognotice incorporates data about all building components that

require maintenance or periodical replacement. Prognotice is used to assist facility manager in

creating a long-term maintenance plan for each component in a building accordingly. Beside storing

building component data, this software also creates a maintenance task schedule and calculate

maintenance cost. At the moment about 38000 building components are recorded by FM UT in

Prognotice.

Page 26: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

24

Furthermore, at the moment, Facility Management University of Twente is still in development period

for the implementation of digital facility data transfer to their maintenance management software.

They are trying to fully leverage digital facility data stored in BIM model for the operational and

maintenance purposes. A BIM model has been generated from one of the existing building managed

by FM UT. BIM model was created using Autodesk Revit as BIM authoring software. The next step to

be taken by the facility managers is to connect the Revit model with Prognotice and then transfer

digital facility data from Revit model to Prognotice as illustrated by Figure 4-1 .

Figure 4-1 BIM authoring software and maintenance management software used by FM UT

Referring to the Maintenance Manager of UT, the main expectation in connecting both softwares and

then applying automatic digital facility data transfer process is to increase the precision and decrease

the human error prone. Utilizing digital facility data will increase the automatization in managing

building component and maintenance data, hence hopefully the work efficiency will increase

accordingly.

4.2. Revit Model and Prognotice Data Analysis

4.2.1. Building Component data in Prognotice

The information regarding the technical aspect of Prognotice was obtained both through an interview

with one of the program developers in Prognotice B.V and a self analysis through direct application of

the software.

4.2.1.1. Object Hierarchy

The object hierarchy structure in Prognotice is presented by Figure 4-2.

Page 27: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

25

Figure 4-2 Prognotice data hierarchy

Highest object in a Project stored in Prognitce is a building group which can consist of several buildings.

Under the building are the space within a building. Space consists of the building component located

in it. The building components are classified based on classification system used by the user, in this

case NLSFB code is used as building component classification system. The building classification

method used by FM UT is based on the Swedish Sfb. The “NL” in NLSFB refers to Netherlands version

of SFB building classification method. The classification code in Prognotice can be found in their

element code. Maintenance task is then assigned to each component.

4.2.1.2. Object and Database

Detailed information of an object is captured in their properties. This object property reflects specific

information of an object type. This object property can be assigned to building group, building, space,

and component. The object properties are basically user defined. The value of the object properties

can be chosed from the data owned by user or from the data provided by Prognotice.

The object property value that provided by Prognotice for instance the building component code and

maintenance tasks that can be chosen from the list in Prognotice. The relation between object and

properties in Prognotice database is presented in the Figure 4-3.

Page 28: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

26

Figure 4-3 Component data relationship

The relationship of component of data or entity stored in database is shown by the class diagram. The

diagram illustrates the logical structure of databases. From the diagram above it can be seen that the

relationship between Group Building and Building, Building and Space, Space and Component,

Component are one to many composition relationships. It means one entity or object is related to

multiple entity and vice versa.

For instance, the relation between Space and Component. A component must have information about

where the component is located in a building. So, a component has to be connected with one space

data. On the other hand, in a single space there might be multiple building components, hence single

data in space might be connected to multiple component data. One component can only have one

space data while one space data can be used by multiple component.

It can be seen from the diagram that several data are connected to each other, however most of the

data are also independent. In other words, the independent data are captured or sourced from

outside the system and is not used by other entity. This independent data what is also called user

defined data.

4.2.2. Building Component data in Revit Model

4.2.2.1. Object Hierarchy

Everything that is part of a BIM model is an object. It includes everything in 3D elements, 2D elements,

views and sheets. All objects in Revit are governed by the same logic, by the same hierarchy of

elements as shown in the Figure 4-4.

Page 29: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

27

Figure 4-4 Object hierarchy in Revit model

A Revit model object hierarchy can be divided into 4-part:

Category

1. Category is a predefined list of classifications under which all elements within Revit fall. Every

element in Revit must belong to a category. Revit has fix list of categories, this list cannot be

deleted or created by user.

Family

2. Families are classes of elements in a category. A family groups elements with a common set of

parameters (properties), identical use, and similar graphical representation. Family is a class of

element belonging to a particular category and representing a particular physical item or

organization concept within a project.

Family Type

3. Under the family, there is family type which is a variation of a Family. Family types within same

family are usually distinguished based upon sizes, capacity, or other commonly recognized

characteristics.

Family Instance

4. The lowest object in Revit object hierarchy is family instance. Family instance is an actual

physical element within the model or project. It refers to a single object in the model. Instances

are the actual items (individual elements) that are placed in the project and have specific

locations in the building (model instances) or on a drawing sheet (annotation instances).

Page 30: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

28

4.2.2.2. Revit Model Object and Database

A model, as used in the context of Building Information Model, is basically an object model. It utilizes

theory developed in computer science for object-oriented programming. This section will discuss

about the object and the data attached to it (properties).

Object Inheritance

In a Revit model, objects are called as Families and their properties as Parameters which is semantics.

The significance of inheritance object data is that it explains how a parameter behaves in terms of its

position in the inheritance tree.

Figure 4-5 Data inheritance in Revit model (source: Guttman, 2013)

As the building elements go to lower level from family to the family Types and finally to the family

Instances, more detailed information can be identified. As illustrated in Figure 4-5 for instance, in

Furniture category, there are several families with different model, for instance, table, chair, etc. From

table family, there are other tables types with different size. Derived from this table size, there are

other tables with certain material. The lowest family instance inherits parameters from its parent.

Parameter Inherit Levels

A single object might have several data which are its own data or data which are inherited from the

object’s parent. There are three objects inherit levels defined:

Built-In

Page 31: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

29

1. Built in parameter consists of basic values that cannot be freely configured by user. They are

editable only within the Family Editor in “Family Parameters”.

Type

2. This parameter is applied to a class of an object for instance family or family type. Properties that

included in to this inherit level for instance a particular model or size of a family object.

Instance

3. This parameter is applied to a single instance. This parameter may include detail of an object that

is not defined in the object types, or the parameter which is not related to the object type. It

enables user to modify the parameter value separately for every instance.

4.2.3. Revit model and Prognotice Data Relationship Type

The component in Prognotice might consist of multiple building elements or instances. There is no

lower object level in the Prognotice hierarchy that represent a single building element. Meanwhile in

Revit, the lowest object in the hierarchy which is family instance, represents a single building element

or an instance. Hence the relation between component in Prognotice and family Instance in Revit

which is located at the same space is a one to many relations. One component in Prognotice

represents multiple family instance in Revit model. This relation is illustrated in the Figure 4-6.

Figure 4-6 Relationship type between component in Revit model and Prognotice

As an example, if there are three windows type A and two windows type B placed in the same space

or room. In Revit model every single window is regarded as an object as an instance, while in

Page 32: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

30

Prognotice these windows will be grouped based on their type or other identical properties as one

component. This relation is illustrated in the Figure 4-7.

Figure 4-7 Relationship type between component in Revit model and Prognotice (2)

4.2.4. Revit model and Prognotice Data Mapping Possibility

The next step is to pair the attributes data between the Family instance in Revit model and component

in Prognotice. To do so, the two systems must have object properties that represent the same building

component attributes. Therefore, the destination field in Prognotice in which family instance

attributes data in Revit model will be transferred to can be identified. Based on the object data

relation in both Revit model and Prognotice, it has been recognized that there are at least four

attributes that represent the same building component attribute. The relation of those attributes and

are illustrated in the Figure 4-8.

Page 33: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

31

Figure 4-8 Data mapping possibility between Revit model and Prognotice

a. Space

First similarity identified from both Revit model and Prognotice is the relation between building

components with the space they are located. Each component in Prognotice refers to a space where

the component is installed. While each family instance in Revit model belongs to a specific location or

space. So basically, the space data of both Revit model and Prognotice can be identified

b. Sub Element Code

Beside by their Space, the components in Prognotice is also categorized based on their sub-element

code which refers to NLSFB building categorization code. One component must have one sub-element

NLSFB code.

In Revit model, the user can choose which classification that is going to be used. The classification can

be imported to Revit. It is possible to use NLSFB as the component classification code. NLSFB code can

be loaded as the assembly code of the family type.

c. Component Type

Another similar attributes between the two system is the component type. This field is available both

in Revit model and Prognotice. The object type in Revit model can be obtained from family type

properties which actually come from the Revit Library. However, unlike in the Revit the field

component type in Prognotice is a user defined.

d. Additional Properties

The additional properties in this case is actually the other attributes regarding component details data.

In Revit model, user can add more attributes to the family instance. The field of this property is called

instance parameter. As explained in previous section, it enables user to modify the parameter value

Revit model Prognotice

Page 34: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

32

separately for every instance. The value of the parameter may be customized since it is defined by

user.

4.3. Identify Required Information for Building Operational & Maintenance

During this stage, the facility data that need to be transferred from Revit model to Prognotice were

identified. It includes the list of building component and its attributes data. Ideally the criteria of which

facility data to be transferred from BIM model should refer to FM UT. However, since this document

is not available therefore the building component to be transferred are identified from the building

component list in the FM UT maintenance plan document. The data refers to building component list

in long-term maintenance plans of several building managed by FM UT which are generated by

Prognotice. The building components are classified based on NL-SFB classification code. The list of

required building component group to be transferred to Prognotice is shown on the Table 4-1.

Table 4-1 Building Component Classification List

Code Description Code Description

10 General Facilities 53 Water

21 External Walls 54 Gasses

22 Internal Walls 55 Cooling Source and Distribution

23 Floors 56 Heat Distribution

24 Stairs and Ramps 57 Air Conditioning

27 Roofs 58 Climate and Sanitary Control

28 Main Load Bearing Construction 61 Central Electrical Service

31 Openings in External Walls 62 Electrical Power

32 Openings in Internal Walls 63 Lighting

33 Opening in Floors 64 Communication

34 Balustrades and Handrails 65 Protection

37 Opening in Roofs 66 Transport

41 External Wall Finishes 67 Building Management System

42 Internal Walls Finishes 71 Fixed Traffic Equipment

43 Floor Finishes 72 Fixed User Equipment

44 Stair and Ramp Finishes 73 Fixed Kitchen Equipment

45 Ceiling Finishes 74 Fixed Sanitary Equipment

47 Roof Finishes 75 Fixed Maintenance Equipment

51 Heat Source 90 Site

52 Removal

The building component attributes data to be transferred refered to the standard component

property set by Prognotice. The list of component property data set by Prognotice are as shown in the

Table 4-2.

Page 35: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

33

Table 4-2 Component Property in Prognotice

No. Component Property No. Component Property

1 Building Code 23 Component Owner

2 Building Description 24 Component Features

3 Space Code 25 Component Year of constructed/Installed

4 Space Description 26 Component Theoretical service Life

5 Main element Code 27 Component Current Condition

6 Main element Description 28 Component Required Condition

7 Element Code 29 Task Maintenance type

8 Element Description 30 Job description

9 Subelement Code 31 Task Cost category

10 Subelement Description 32 Task Number

11 Component Description 33 Task Unit

12 Component Quantity 34 Task Unit Price

13 Component Unit 35 Task Start year

14 Component Manufacturer 36 Task Cycle

15 Type 37 Project_ID

16 Component Reference 38 Administrator_ID

17 Component Comments 39 Building_ID

18 Component Executive 40 Space_ID

19 Component Location 41 Comp_ID

20 Component Quantity 42 Task_ID

21 Component size 43 Visit_ID

22 Component size unit

4.4. Identify Data Format

Prior to start formulating the data transfer mechanism, the data format that is compatible with both

Revit model and Prognotice was identified. The format that is compatible with Maintenance

management software determines on which data transfer approach can be implemented.

Technically, beside the manual data input, building component data can be imported to Prognotice

from spreadsheet Ms. Excel format (.xls). Since spreadsheet file in Ms. Excel format (.xls) is data format

which can be exported from Revit model, therefore, this file format is chosen by researcher as an

exchange data format between both Revit model and Prognotice.

4.5. Summary

It has been identified in this chapter that Prognotice is used by FM UT to create the long term

maintenance plan. All the facility data needed for the maintenance purpose are populated to this

software. On the other hand, BIM model of one of the building they manage has been generated using

Page 36: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

34

Autodesk Revit, a BIM authoring software. Therefore, a connection between Revit and Prognotice has

to be established to transfer digital facility data.

Furthermore, the data analysis performed in this chapter was able to give information about the

comparison between data in Revit model and Prognotice so that the possible connection between the

two softwares could be determined. The data or object structure stored in both Revit model and

Prognotice also has been identified, followed by required information that has to be transferred from

BIM model to maintenance management software. Finally, the file exchange format which compatible

with both Revit and Prognotice is defined. This information was then used as a basis in formulating

the dgital facility data transfer approach from BIM model to maintenance management software

which is discussed in the following chapter.

Page 37: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

35

5. Facility Digital Data Transfer Workflow

The proposed workflow is divided into four main steps; Collect, Restructure, and Transfer. It is started

by collecting the required building component data from BIM model. The extracted building data

however might have a different structure with the required data structure by the maintenance

management software, hence restructuring the building data has to be performed accordingly. Once

the well-structured database has been created, the building data are ready to be transferred to

maintenance management software. In order to effectively perform all these processes, technical tool

which have ability to collect, restructure and transfer the data is required. The aforementioned

process is illustrated by the flowchart in Figure 5-1.

Figure 5-1 Proposed BIM Based building data transfer workflow.

Facility Management Revit model Middleware Prognotice

Yes

Yes

No

No

Preparation Stage

Page 38: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

36

The process of the BIM based building data transfer is technically started with the creation of the BIM

model which as indicated by the dashed-line box. However, how the preparation and the BIM should

be generated is not part of this study. Hence, the workflow that will be implemented in this study is

started after the creation of the BIM model until all the building components data for maintenance

purpose are transferred to the maintenance management software. There are three main actions to

be performed in this workflow to transfer digital building data from BIM model to maintenance

management software:

1. Collect

Assuming that all the important building data for maintenance purpose has been included in to the

BIM model, the next step is to collect the necessary building data from BIM model. As explained before

that everything modeled in Revit is an object, so it is important to know which object that is going to

be collected at the first place. In this case, the object from Revit model that is going to be collected is

the building components.

Furthermore, extracting all the building elements and their attributes data contained in BIM model

for the maintenance purpose will only produce a lot of redundant data. It is important to only query

and collect the necessary building information for the maintenance purpose. In Revit model, a building

component can be recognized or distinguished by several criteria. For instance, by the component

category, type, or even their detail attributes such as size, capacity, identification number, material,

etc. The collected building components then has to be filtered based on the criteria set. The output of

this process is the list of building component and their attributes data which is considered by Facility

Managers needs to be transferred to the maintenance management software.

2. Restructure

The building component data collected from BIM model may contain data that is structurally different

and incompatible with what is required by maintenance management software. To be read accurately,

maintenance management software might require a specific data format and structure. This data

structure includes data value naming convention and data file format. Therefore, data processing is

required in order to generate a data to be correctly read by the maintenance management software.

The process might include data sorting, translating and editing thousands of data.

The information about how data structure in the maintenance management software therefore

becomes essential. The building component data structure extracted from BIM model then compared

with the required data structure in maintenance management software. The building component data

Page 39: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

37

structure from BIM model is adjusted accordingly. Next, the well-structured building component data

is exported to a file format which is compatible with the maintenance management software in this

case the data is exported to excel spreadsheet file. The building component data restructuring process

involves repetition process of large amounts of data. Therefore, the process has to be performed using

a tool or middleware that capable to complete all the actions accurately.

3. Transfer

The next step is to transfer the well-structured building component database to the maintenance

management software. However, prior to perform this action, the final structure of the database has

to be checked to ensure its compatibility with the maintenance management software. Once the

building component database has been arranged in a proper structure then structured building

component database is then ready to be imported to the maintenance management software.

The building component data import process is conducted iniside Prognotice. There is one option in

Prognotice to import the building component data from excel spreadsheet file. The first step is by

opening the excel spreadsheet file which already contain building component data to be transferred.

This step is followed by selecting the destination data field in Prognotice to be populated with data

from spreadsheet file. After all set, the import process can be started which automatically performed

by Prognotice.

Page 40: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

38

6. Case Study and Implementation

The proposed approaches described above are implemented for a building digital data transfer of High

Pressure Laboratory building at University of Twente, Enschede, Netherlands. The building which has

been renovated and re-opened in 2016 is the first building managed by FM UT that utilize BIM model

as the building data repository platform.

A case study is performed in order to see the practical effectiveness of the proposed workflow. The

proposed digital building data transfer method is implemented to transfer data from BIM model

generated after the building renovation and the existing maintenance management software used by

FM UT.

Figure 6-1 Tools or software used in the case study

Figure 6-1Figure 6-1 Tools or software used in the case studyFigure 6-1). Dynamo is a visual

programming tool that facilitate both non-programmers and programmers to develop algorithm or a

step by step set of actions that follow a basic logic of input, processing, and output (Autodesk, 2016).

An algorithm is formulated to execute the actions explained in the previous chapter, so that all the

actions can be done automatically. This algorithm is used to automatically collect, filter, and

restructure the building component data from BIM model and then export them to spreadsheet file.

6.1. Collect Building Component Data from Revit Model

The first step of this process is to collect building component data for the maintenance purpose. Not

all the building component will be collected. Only the building component data that is by FM UT

considered to be the component which need maintenance and thus have to be populated to the

Prognotice, that will be collected. However, when this research was performed, what components to

be included in the Prognotice is still under discussion by FM UT. The final component list has not

finished yet. Hence, for this study the building components those are regarded as building component

Page 41: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

39

that need to be maintained are the building component with NLSFB code assigned to the element

properties.

Beside the building component list, the building data has to be complemented by the attributes of the

component. Which attributes to be selected is based on the building information needed by

Prognotice (Table 4-2) and component attributes data available in Revit model. The space data where

the building component are located is a required data to be transferred to Prognotice. However, due

to the limitation of the Revit to assign space information of all component automatically, hence the

space data of components are assigned manually to the Revit model. The limitation is occurred due to

nature of Revit model that defined the space/room boundary based on the outermost line of the wall.

Hence, the location or space of the building component that is installed one the wall for instance

windows couldn’t be automatically defined. Moreover, for multiple element categories such as ducts

and pipes the space attributes can’t be generated automatically.

The building component data attributes to be selected from Revit model hence as follows:

Table 6-1 Element Properties to be Exported

No Revit Element Properties Prognotice Component Data

1 Element ID -

2 Space Code Space Code

3 Space Description Space Description

4 Assembly Code Sub-element Code

5 System Type Sub-element Code

6 Category Component Description

7 Type Type

The table above shows the building element attribute data collected from Revit model and the relation

to the building component data in Prognotice. The Revit element properties in the left column then

will be populated to the Prognotice component data field in the right column.

As a tool to execute this operation, Dynamo is used. Dynamo is a visual programming tool that

facilitate both non-programmers and programmers to develop algorithm or a step by step set of

actions that follow a basic logic of input, processing, and output (Autodesk, 2016). Dynamo was

originally created for use with Revit. Dynamo for Revit extends building information modeling with

the data and logic environment of a graphical algorithm editor.

Page 42: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

40

The first action to be taken is to collect all the elements in Revit model. From all this elements, only

element that assigned by Assembly Code in their attributes which will be select. Hence, the elements

is filtered by this criteria. The elements those have value for the Assembly Code parameter are

separated with those who don’t have value. Only elements those have value that will be put into the

list and proceeded to the next step. The node to perform this action is shown in the Figure 6-2.

Figure 6-2 Element filtering

After all the elements with Assembly Code has been included in to the list, the next action in the

Dynamo algorithm is to call the parameter value of each element to be included to the list (Figure 6-3).

Figure 6-3 Get elements parameter value nodes

Up to this point, the list of elements and their parameter have been obtained. The next step is to

compile and arrange them in a good list order. So, the list is compiled using “List.Create” node to

combine the elements and their parameters in one list. The “List.Transpose” node is used to swap the

row to columns to make the list in the spreadsheet to be in a good order.

Page 43: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

41

The last action of this process is to export the list to the spreadsheet file. This action can be performed

by utilizing the “Excel.WriteToFile” node. This node required six inputs comprising the file path where

the list will be exported, the sheet name, the start row and column where the list will be written, and

the option whether to overwrite the file each time the algorithm is performed. The nodes to execute

this action is shown by te Figure 6-4.

Figure 6-4 List management and export nodes

The full algorithm for this process can be found in APPENDIX C.

6.2. Restructure Database

To get how the database structure should be, the exported building component data is compared with

the structured of the maintenance data exported from Prognotice. The building component data

exported from Revit model is then restructured accordingly. The sample of maintenance data

structure is taken from the maintenance planning data of buildings in University of Twente area which

is managed by FM UT. After comparing both data structure, several data adjustments were made:

a. Adjust the data value naming

The naming of NLSFB code in Revit model found to be different with in the Prognotice. In Prognotice

NLSFB code which is described in the element codes consists of six digits number. Meanwhile in Revit

model, NLSFB code can be found in multiple naming standard. Dynamo algorithm was created to

perform the value change automatically. The algorithm first collects the NLSFB code value from Revit

model and then eliminate the unnecessary character such as non-numerical character. All the NLSFB

code must contain exactly six digits to fill the Sub-element code in Prognotice. Additional character (0)

was added to the code that have less than six digits. However, NLSFB code can be identified for the

Page 44: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

42

element which have at least two digits code. For the elements which have only one digit code, the

NLSFB code result will become “0” that means NLSFB code could not be identified. The dynamo

algorithm to execute these actions is presented in Figure 6-5.

Figure 6-5 Dynamo algorithm for NLSFB code restructuring

The example of the NLSB code name restructuring is showed by Table 6-2.

Table 6-2 NLSFB Code Naming Before and After Restructured

Revit model NLSFB Code Restructured NLSFB Code

2 0

2C 0

2B(28.11.21) 281121

2E(32.31) 323100

(28.d) 280000

(54.11) gassen, brandstof, aardgas

541100

b. Filling the empty required fields

Building data to fill in multiple Prognotice required fields are not directly available in the building

component attributes data from Revit model. Those fields such as building code, building description,

key element code, and element code. The building code and description is filled in manually the

spreadsheet file. The value is the same for the all the components. For this study, the building code is

filled in with random number “99”, while the building description is filled in with “High Pressure

Laboratory”.

Page 45: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

43

On the other hand, key element code and element code are extracted from the six digits sub-element

code which is NLSFB classification code. Key element code and element code are the first 2 and 4 digits

of the sub-element code respectively. How those codes are extracted is illustrated in the Figure 6-6 .

Figure 6-6 Key element, element, and sub-element code in Prognotice

Dynamo algorithm is created to extract the key element and element code from sub-element code

automatically. The algorithm or node of Dynamo is shown by Figure 6-7.

Figure 6-7 Dynamo algorithm to generate key element and element code

In this step, any other empty fields that considered to be important but not available in the BIM model

can be filled in. Due to unavailability of data, in this study there is no additional data added.

c. Group the component with identical attributes data.

Due to “one to many” relationship between Prognotice and Revit model which means one component

ID in Prognotice represents multiple building element in Revit model with identical criteria placed in

323121 Key Element

Code

Element Code

Sub-Element

Code

Page 46: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

44

the same space as explained in chapter 4.1.3. Therefore, building element are grouped based on their

attributes data. The quantity of of identical component located in the same space is then calculated.

In Prognotice, one of the most important component field to be filled in is a quantity of the

component. It is useful to calculate the total maintenance task cost for the long-term maintenance

plan. The building component quantity is defined by calculating the number of building component

with the same criteria located in the same space. In Prognotice, the component quantity can be

calculated based on several units, for instance STK (piece), m, m2, m3, etc. However, in this study, the

quantity of the component extracted from Revit model is calculated in STK (piece). The Dynamo

algorithm to execut these actions is shown by Figure 6-8

Figure 6-8 Element grouping and quantity counting in Dynamo

The sample of the structured data is presented in Table 6-3. The full structured data can be found in

APPENDIX

Table 6-3 Structured Building Component Data

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

Ele

men

t C

od

e

Elem

ent

Co

de

Sub

-Ele

men

t C

od

e

Sub

-Ele

men

t

Des

crip

tio

n

Qu

anti

ty

Un

it

Typ

e

99 High Pressure Lab

INMA01 Interior Mounting Area

28 2800 280000 Walls 9 STK Type : 300_28_betonsteen_210mm

99 High Pressure Lab

INCA01 Interior Common Area

28 2800 280000 Walls 40 STK Type : 300_28_betonsteen_210mm

99 High Pressure Lab

INPH01 Interior Process Hall

28 2800 280000 Walls 8 STK Type : 300_28_betonsteen_210mm

Page 47: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

45

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

Ele

men

t C

od

e

Elem

ent

Co

de

Sub

-Ele

men

t C

od

e

Sub

-Ele

men

t

Des

crip

tio

n

Qu

anti

ty

Un

it

Typ

e

99 High Pressure Lab

EXEF01 Exterior Façade 21 2111 211111 Walls 52 STK Type : 300_21_metselwerk_100

99 High Pressure Lab

INMA01 Interior Mounting Area

28 2800 280000 Walls 1 STK Type : 300_28_betonsteen_320mm

99 High Pressure Lab

INCA01 Interior Common Area

21 2111 211111 Walls 5 STK Type : 300_21_metselwerk_210 bruin

99 High Pressure Lab

INCA01 Interior Common Area

21 2111 211111 Walls 3 STK Type : 300_21_metselwerk_100 bruin

99 High Pressure Lab

INCA01 Interior Common Area

28 2800 280000 Walls 1 STK Type : 300_28_betonsteen_320mm

99 High Pressure Lab

INCA01 Interior Common Area

28 2800 280000 Walls 20 STK Type : 300_28_betonsteen_100mm

99 High Pressure Lab

INCA01 Interior Common Area

28 2800 280000 Walls 5 STK Type : 300_23_schoorsteen_bekleding

6.3. Import Data to Prognotice

The structured building component data is then imported to the Prognotice through the Prognotice

import feature as show in Figure 6-9.

Figure 6-9 Prognotice data import

Page 48: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

46

The top part as shown in the Figure 6-9 is the building component data from excel file exported from

Revit model. At the bottom part, are the list of the building component data field in long term

maintenance plan Prognotice. To import the building data from excel file, the Prognotice fields column

to be filled is checked and link it to the column from the excel table in which the data will be imported.

6.4. Building Component Data Import Result

It took more or less a day to complete all the process from collecting data from Revit model until

importing them to the Prognotice. The result of this process can be checked in Prognotice as shown

by Figure 6-10.

Figure 6-10 Building data transfer result in Prognotice

Figure 6-10 shows that the building data component list from Excel spreadsheet file has been

successfully transferred to the Prognotice. On the left part, it shows the list of building component

while in the right side, it shows the list of the defined space within the building. The component

properties can be seen by clicking one of the sub-element/components. It will then display new

window as shown in the Figure 6-11.

Page 49: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

47

Figure 6-11 Component attributes data in Prognotice

The component details window shows that component attributes data has been transferred and read

by Prognotice. In this window it can be seen that the key element code, element code, sub-element

code, component description, quantity, and type data are already inside the Prognotice system.

From the result can be seen that there are multiple columns automatically generated by Prognotice.

Those columns are key element description, element description, and subelement description. These

columns or fields are generated based on the the NLSFB code in the imported data and the NLSFB

database in Prognotice.

6.5. Result Validation

The overall result is checked by exporting the maintenance plan data from Prognotice to Ms Excel

spreadsheet file. This data is then compared with the building component data which was imported

to Prognotice to see if all the data are successfully imported or transferred to Prognotice. The result

shows that 5072 of 5072 elements from Revit model which includes the building component list and

their attributes are imported to Prognotice. However, there are empty fields found on sub-element

code filed for several component. This field is supposed to be automatically field by Prognotice,

however, the NLSFB code extracted from BIM model for these components are not available in NLSFB

code data used in Prognotice. As the result, those subelement code could not be recognize by the

system. The sample of the result is presented in Table 6-4. The full result can be seen in APPENDIX E.

Page 50: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

48

Table 6-4 Building Component Data Extracted from Prognotice G

eb

ou

w C

od

e

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXEF01

Exterior Façade

Floors Type : 200_23_dak_fietsenberging 1 STK 230 263 319 10929 111043

99 High Pressure Laboratory

EXEF01

Exterior Façade

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_100 52 STK 230 263 319 10929 110833

99 High Pressure Laboratory

EXEF01

Exterior Façade

22 Binnenwanden

2221 Constructief, massieve wanden

222141 Walls Type : 300_22_ihw beton_100 4 STK 230 263 319 10929 110859

99 High Pressure Laboratory

EXEF01

Exterior Façade

22 Binnenwanden

2221 Constructief, massieve wanden

222141 Walls Type : 300_22_ihw beton_210 40 STK 230 263 319 10929 110864

99 High Pressure Laboratory

EXEF01

Exterior Façade

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonklinkers 2 STK 230 263 319 10929 111014

99 High Pressure Laboratory

EXEF01

Exterior Façade

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 11 STK 230 263 319 10929 110855

99 High Pressure Laboratory

EXEF01

Exterior Façade

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_beton_ihwg_400mm 3 STK 230 263 319 10929 110863

99 High Pressure Laboratory

EXEF01

Exterior Façade

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-76-12 2 STK 230 263 319 10929 110914

99 High Pressure Laboratory

EXEF01

Exterior Façade

31 Buitenwandopeningen

3141 Gevuld met puien, gesloten puien

314100 Gevuld met puien, gesloten puien, Algemeen

Windows Type : 31_paneel ver 1 STK 230 263 319 10929 111045

99 High Pressure Laboratory

EXEF01

Exterior Façade

31 Buitenwandopeningen

3141 Gevuld met puien, gesloten puien

314100 Gevuld met puien, gesloten puien, Algemeen

Windows Type : paneel ver 2 STK 230 263 319 10929 111046

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_glasvezel_beton 7 STK 230 263 319 10929 110895

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_glasvezel_beton boven Rodeca wand

2 STK 230 263 319 10929 110897

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_glasvezel_beton achter 3 STK 230 263 319 10929 110898

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_techniek ruimtes 1200

11 STK 230 263 319 10929 111012

Page 51: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

49

7. Discussion and Conclusion

7.1. Discussion

The result confirms that the application of Collect, Restructure, and Transfer to implement digital

facility data transfer from BIM model to maintenance management software has successfully transfer

building component data from Revit model as a BIM authoring software to Prognotice as maintenance

management software. The case study has proved that the use of BIM model enables the automatic

building component data input to maintenance management software so that the manual building

data input can be significantly reduced. Moreover, the case study has demonstrated how the

proposed approach is implemented to the existing condition. From

Furthermore, the BIM model building component data collecting process has been proven to eliminate

the redundant building data contains in BIM model. The problem of oversized and unnecessary data

in BIM model as claimed by Zadeh et.al (2015) to be common obstacle in BIM-FM integration can be

solved. However, the criteria on what information to be transferred from BIM model to maintenance

management software ideally defined by the facility management. It has to be adjusted with their

need (Teicholz, 2013). However, this document is not available during this research which made it one

limitation of this study. Ideal result is expected to be achieved if the study used the real building data

selection criteria prepared by FM.

The data restructuring process on the other hand has answered the interoperability challenge that

was claimed by Nagshbandi (2016) to be one of the main barriers that might be faced in the building

digital data transfer process. The data restructure process implemented in case study has translated

the facility data in BIM model so that it can be read and then transferred to maintenance management

software. The building data restructuring process performed in this study has proved that a

modification of the building database exported from BIM model has to be done to create a structured

data which can be correctly read by maintenance management software.

Practical differences between conventional building data transfer method by FM UT and digital facility

data transfer method proposed in this study can be identified. The comparison between both practices

are presented in Table 7-1.

Page 52: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

50

Table 7-1 Conventional vs Digital Facility Data Transfer Method

No. Criteria Conventional Method Digital Data Transfer Method

1 Building data source format

Paper-based and 2D CAD drawings Digital data in BIM model

2 Data storage Hard drive and document storage room

Hard drive or server

3 Duration at least 2 weeks 1 day

4 Tools Computer program for manual data input

Middleware or other tools for automatic data processing

5 Collecting building component data

Manual Automatic

6 Processing building component data

Manual Automatic

7 Importing building component data

Manual Automatic

From the Table 7-1, significant improvement can be seen in the building data transfer process. The

conventional method relied on the manual process while digital facility data transfer method could

enable the automatic building data transfer process. As the result, FM can benefit from the duration

needed to complete the process which can be shortened. Significantly reduced manual practice is

regarded to be the main aspect that influence the duration of the building data transfer process.

Another benefit that FM can obtain from the automatic facility data processing and transferring is its

precision which can potentially reduce error prone. Other improvement can be seen in the data

storage system, a dedicated room to store paper documents might no longer required since the

building data source switched from paper documents to digital building data in BIM model.

Despite the result that 100% building component data has been transferred to Prognotice, however

the building data imported from Revit model only filled in 13 columns out of more than 100 provided

by Prognotice. Moreover, the fields those are potentially useful for maintenance purpose and

maintenance plan such as component manufacturer, component installation year, component

construction year, component theoretical life, component current condition, component required

condition are not found in Revit model.

Therefore, the concern of the result lies on the quality of the data transferred to the maintenance

management software. The finding by Aziz et al (2016) which said building data in BIM model can be

transferred without having to re-enter it manually to the maintenance management system has to be

considered carefully. This benefit is only applicable with a condition that BIM model has provided all

the information needed for maintenance purpose. If this condition is not adequately fulfilled as found

in the case study of this research, consequently, missing data have to be re-entered to the

maintenance management software.

Page 53: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

51

The case studies performed by Teicholz (2013) show that the facility managers involvement in

determining what information to be included in BIM model is essential for the effective BIM

implementation for the FM. However, this is something that might not optimally applied by FM UT

prior to the BIM model of High-Pressure Laboratory building was created. Due to many unavailable

maintenance information, as the consequences, additional data related to maintenance purpose has

to be populated and manual data input might be required for this process. The FM UT in this case,

should consider to also include the maintenance data in their delivery information standard used as

reference for the BIM model creation.

Therefore, the technical issues such as interoperability problem that is claimed as the main barriers

for the BIM-FM integration by previous researches (Naghshbandi, 2016) (Teicholz, 2012) apparently is

not the first and only thing to be solved by the FM. Incomplete building data for maintenance purpose

contained BIM model as found in this case study shows that facility managers should first create their

BIM information delivery standard and establish a collaboration with the BIM model creator prior the

BIM model creation and facility data transfer process. The result of this research shows that, in order

to perform an effective BIM based building data transfer to maintenance management software, it is

not only the digital building data transfer approach which is essential but also the method how the

BIM model was created.

On the other hand, a slight technical adjustment can be made to the current FM UT building data

transfer process includes the procurement of the middleware or tools which capable to perform all

the actions mentioned in this research. A development of proprietary program can be considered as

another option. Process adjustment has to be made especially for the BIM model preparation and

creation process. In order to optimally implementing digital facility data transfer, FM should also

consider the appropriate method in generating the BIM model which has been studied in several

previous researches. For example, Thabet & Lucas (2017) who proposed steps to be considered and

prepared in implementing BIM-FM integration or McArthur (2015) and Carbonari et.al (2015) which

proposed an iterative process as a framework to generate BIM model for existing building. The digital

facility data transfer approach formulated in this study then can be tailored with the most suitable

BIM model creation method and compile them as a BIM implementation plan for FM.

Eventually, there are a lot of space for improvements and expansions towards other topics related to

BIM based building data transfer for FM. More case studies are needed in order to demonstrate the

implementation of the BIM based building digital data transfer approach for another building or

maintenance management software. More findings to the implementation will give a positive input

Page 54: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

52

for the improvement of the developed approach. A generalized framework then can be potentially

developed accordingly.

Moreover, the use of more integrated tools to process the data for the digital building data transfer

operation might result to a seamless process and potentially can reduce error prone. Nevertheless,

the used of Dynamo for instance, to collect, restructure and export building component data from

BIM model has provided accurate result. The logic and workflow presented in this study has

demonstrated the actions should be taken in order to execute a building digital data transfer from

BIM model to maintenance management software. This workflow hence can be potentially adopted

not only to execute another case with similar condition but also to develop the tools or program to

perform the digital facility data transfer process for the future research.

The overall process of BIM-FM integration however is not limited until the digital building data has

been transferred to maintenance management software. It is actually the beginning stage of the

overall BIM and FM integration. However, with the successful implementation of the digital building

data transfer process, it opens huge opportunity to conduct a study in more extended topic related to

BIM – FM integration.

7.2. Conclusion

The digital facility data transfer from BIM model to existing maintenance management system

formulated in this study has proposed main actions to be taken to perform effective building digital

data transfer from BIM model to existing maintenance management software. The case study

performed has demonstrated more detailed actions to be taken in order to effectively transfer

building component data from BIM Model to maintenance management software. It also confirms the

potential challenge experienced and benefit received by the FM. The result of the case study shows

that the proposed workflow has successfully transferred building digital data to maintenance

management software.

Admiteddly, several limitations can be found in this study. More case studies need to be conduct and

the use of more varied facility data and tools to execute the facility data transfer can also be applied

to optimize the overall facility data transfer process. The limitation of the result and process however

provides a lot of opportunities for the future research both to improve the overall process as well as

to extend the study for the proceeding process.

Page 55: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

53

References

Aðalsteinsson, G. Ó. (2014). Feasibility study on the application of BIM data for facility management. Reykjavík: Reykjavík University.

Aziz, N. D., Nawawi, A. H., & Ariff, N. R. (2016). ICT Evolution in Facilities Management (FM): Building Information Modelling (BIM) as the Latest Technology. Procedia - Social and Behavioral Sciences, 363-371.

Beatty, R., Eastman, C., Kim, K., & Fang, Y. (2013). Texas A&M Health Science Center,[Case Study]. In BIM for Facility Managers (pp. 164-184). New Jersey: John Wiley & Sons.

Becerik-Gerber, B., Jazizadeh, F., & Li, N. (2011). pplication areas and data requirements for BIM-Enabled Facilities Management. Journal of construction engineering and management.

Borthwick, A., & Soffer, M. (2004). Business Requirements of a Recored Matching System. Ninth International Conference on Information Quality (IQ 2004) (pp. 433-446). ChoiceMaker Technologies, Inc.

Carbonari, G., Stravoravdis, S., & Gausden, C. (2015). Building Information Model Implementation For Existing Buildings For Facilities Management: A Framework And Two Case Studies. In Building Information Modelling (BIM) in Design, Construction and Operations (pp. 395-406). Greenwich: Witt Press.

Cavka, H. B., Staub-French, S., & Poirier, E. A. (2017). Developing owner information requirements for BIM-enabled project delivery and asset management. Automation in Construction, 169-183.

Christen, P. (2012). Data Matching. Berlin Heidelberg: Springer.

DSF. (2011). Digital Facility Management Information Handover: Current DSF Practices, Industry-wide Movement; Future Directions. The State of Wisconsin, Department of Administration, Division of State Facilities.

Eadie, R., Browne, M., Odeyinka, H., McKeown, C., & McNiff, S. (2013). BIM implementation throughout the UK construction project lifecycle: An Analysis. Automation in Construction, 145-151.

East, B. (2010, December). COBie: Case Studies and Innovations. Retrieved from National Institutes of Building Sciences: https://portal.nibs.org/files/wl/?id=4i7UzmOI3604GNaw7Sh6DjlTBCehXfLG

EC. (2018). Eurostat. Retrieved from European Commission: https://ec.europa.eu/eurostat/cros/system/files/s-dwh-m_4.2_methodology_data_linkage_v2.pdf

Fallon, K., & Palmer, M. (2007). Capital Facilities Information Handover Guide, Part 1. National Institute of Standard and Technology.

Ghosh, A., & Chasey, A. D. (2013). Data Handover for Healthcare Facilities Management. Arizona: Arizona State University.

Guttman, M. (2013, November 5). Advanced Techniques for Managing Building Data in Autodesk Revit. Autodesk University 2013.

Hamil, S. (2017, April 7). What is COBie? Retrieved from NBS: https://www.thenbs.com/knowledge/what-is-cobie

Hu, Z.-Z., Tian, P.-L., Li, S.-W., & Zhang, J.-P. (2018). BIM-based integrated delivery technologies for intelligent MEP management in the operation and maintenance phase. Advances in Engineering Software, 1-16.

Ibrahim, K., Abanda, F., Vidalakis, C., & Woods, G. (2016). BIM for FM: Input versus Output data. 33rd CIB W78 Conference. Brisbane: Researchgate.

IFMA. (2013). Retrieved January 22, 2018, from International Facility Management Association (IFMA): http://www.ifma.org/about/what-is-facility-management

Kensek, K. (2015). BIM Guidelines Inform Facilities Management Databases: A Case Study over Time. Buildings, 899-916.

Kim, K., Kim, H., Kim, W., Kim, C., Kim, J., & Yu, J. (2018). Integration of ifc objects and facility management work information using semantic web. Automation in Construction, 173-187.

Page 56: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

54

Kiviniemi, A., & Codinhoto, R. (2014). Challenges in the Implementation of BIM for FM: Case Manchester Town Hall Complex. 2014 International Conference on Computing in Civil and Building Engineering. Orlando: American Society of Civil Engineers.

Lu, Q., Chen, L., Lee, S., & Zhao, X. (2018). Activity theory-based analysis of BIM implementation in building O &M and first response. Automation in Construction, 317-332.

McArthur, J. J. (2015). building information management (BIM) framework and supporting case study for existing building operations, maintenance and sustainability. Procedia Engineering, 1104-1111.

McGraw-Hill Construction. (2014). The business value of BIM for owners. Retrieved January 2018, from http://group.skanska.com/globalassets/about-us/building-information-modeling/business-value-of-bim-for-owners-smr-2014.pdf

Naghshbandi, S. N. (2016). BIM for Facility Management: Challenges and Research Gaps. Civil Engineering Journal, 679-684.

NIBMS-US. (2018, March). FAQ on the NBIMS-US. Retrieved from National BIM Standard United States: http://www.nationalbimstandard.org/faq.php#faq1

Nicał, A. K., & Wodyński, W. (2016). Enhancing Facility Management through BIM 6D. Procedia Engineering, 299-306.

Parsanezhad, P., & Dimyadi, J. (2014). Effective Facility Management and Operations via a BIM Based Integrated Information System. CIB Facilities Management Conference 2014 (pp. 442-453). Copenhagen: International Council for Research and Innovation in Building and Construction.

Pishdad-Bozorgi, P., Gao, X., Eastman, C., & Self, A. P. (2018). Planning and developing facility management-enabled building information model (FM-enabled BIM). Automation in Construction, 22-38.

Ravetz, J. (2008). State of the Stock What do we know about existing buildings. Energy Policy, 4462-4470.

Rebekka Volk, J. S., & Schultmann, F. (2013). Building Information Modeling (BIM) for existing buildings — Literature review and future needs. Automation in Construction, 109-127.

Sapp, D. (2016, December 9). Computerized Maintenance Managemen Systems (CMMS). Retrieved from Whole Building Design Guide: https://www.wbdg.org/facilities-operations-maintenance/computerized-maintenance-management-systems-cmms

Teicholz, E., & Fellow, I. (2004). Bridging the AEC/FM Technology Gap. IFMA Journal, 1-8.

Teicholz, P. (2013). BIM for Facility Managers. Hoboken, New Jersey: John Wiley & Sons.

Thabet, W., & Lucas, J. D. (2017). A 6-Step Systematic Process For Model-Based Facility Data Delivery. Journal of Information Technology in Construction, 104-131.

U.S GSA. (2011). BIM Guide for Facility Management. Washington, DC: General Service Administration.

Volk, R., Stengel, J., & Schultmann, F. (2014). Building Information Modeling (BIM) for existing buildings — Literature review and future needs. Automation in Construction, 109-127.

Watson, J. R., & Watson, R. (2016, December 9). Computer Aided Facility Management. Retrieved from Whole Building Design Guide: https://www.wbdg.org/facilities-operations-maintenance/computer-aided-facilities-management-cafm

Williams, R., Shayesteh, H., & Marjanovic-Halburd, L. (2014). Utilising Building Information Modeling For Facilities Management. International Journal of Facility Management.

Zadeh, A., P., Staub-French, S., & Pottinger, R. (2015). Review of BIM quality assessment approaches for facility management.

Page 57: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

55

APPENDIX A

INTERVIEW QUESTIONS

Page 58: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

56

1. General Information about the interviewee.

i. What is your current position in Facility Department of University of Twente? And

what is your responsibility?

2. The current handover workflow.

ii. How the facility data was collected and transferred to the facility management

system?

iii. What are the format of the building information documents that you received from

contractor?

iv. Where are all building data information stored?

v. Do you still input the facility data to the facility management system manually? If so,

what are the facility data that still manually transferred to the FM software and how

is it done?

vi. How long approximately does the current facility data transfer process take?

vii. How many personnel do you need to complete the facility data transfer process?

viii. What facility management software do you use?

ix. What practical standards and codes for implementation of the facility data transfer

process do you use?

3. Problem faced during the current handover process. (mention the technical)

x. What are the technical problems faced during the current facility data transfer

process?

xi. What are the critical problems that need to be fixed?

4. The goal of organization in using BIM model for digital data handover process.

xii. What is the organization’s main expectation in implementing digital facility data

transfer process?

Page 59: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

57

APPENDIX B

HIGH PRESSURE LABORATORY BUILDING BIM MODEL PREVIEW

Page 60: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

58

3D VIEW

Page 61: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

59

North Section (Front)

South Section (Back)

West Section (Right side)

Page 62: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

60

East Section

Ground Floor Floorplan

Page 63: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

61

APPENDIX C

DYNAMO ALGORITHM

Page 64: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

62

Part 1

Page 65: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

63

Part 2

Page 66: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

64

APPENDIX D

EXPORTED BUILDING COMPONENT DATA RESULT

Page 67: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

65

B

uild

ing

Co

de

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 9 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 40 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 8 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

21 2111 211111 Walls Type : 300_21_metselwerk_100 52 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2800 280000 Walls Type : 300_28_betonsteen_320mm 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

21 2111 211111 Walls Type : 300_21_metselwerk_210 bruin 5 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

21 2111 211111 Walls Type : 300_21_metselwerk_100 bruin 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_28_betonsteen_320mm 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_28_betonsteen_100mm 20 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_23_schoorsteen_bekleding 5 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2800 280000 Walls Type : 300_28_beton_ihwg_400mm 53 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2800 280000 Walls Type : 300_28_betonsteen_100mm 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2800 280000 Walls Type : 300_22_drijfsteen_100mm 60 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

23 2321 232142 Floors Type : 300_23_betonvloer_200 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

47 4710 471000 Floors Type : 300_43_heraklith_50mm 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

32 3231 323100 Doors Type : dagmaat 0850x2000 10 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

32 3230 323000 Doors Type : rozet 20 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2800 280000 Walls Type : 300_28_beton_ihwg_280mm 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Floors Type : 200_23_basisvloer_200mm 1 STK

Page 68: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

66

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2800 280000 Walls Type : 300_28_betonsteen_100mm 9 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2800 280000 Walls Type : 300_32_rooster_boven_kozijn 5 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323100 Doors Type : merk c-865 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3230 323000 Doors Type : rozet 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323100 Doors Type : merk e 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Floors Type : 200_23_basisvloer_200mm 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 11 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_basisvloer_200mm 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_basisvloer_150mm 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Walls Type : 200_23_ventilatieopbouw_dak 7 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

22 2221 222141 Walls Type : 300_22_ihw beton_100 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

22 2221 222141 Walls Type : 300_22_ihw beton_100 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_basisvloer_80mm 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Floors Type : 200_23_basisvloer_150mm 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

28 2800 280000 Walls Type : 300_28_beton_ihwg_400mm 3 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

22 2221 222141 Walls Type : 300_22_ihw beton_210 40 STK

99 High Pressure Laboratory

ING01 Interior General

0 0 0 Floors Type : 200_23_basisvloer_300mm 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Floors Type : 200_23_basisvloer_100mm 1 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

90 9010 901000 Floors Type : 200_99_terrein 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323100 Doors Type : merk 120 1 STK

Page 69: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

67

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

43 4300 430000 Floors Type : 200_43_afwerkvloer_150 9 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

83 8310 831000 Furniture Type : HDL_opstelplaatsen 43 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

83 8310 831000 Generic Models

Type : opstelplaats wasbak 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

32 3231 323121 Doors Type : H02 4 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

31 3131 313100 Curtain Panels

Type : deur 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

41 4112 411200 Walls Type : 300_41_tegelwerk 30 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

43 4322 432231 Floors Type : 300_43_tegelvloer_300x300_20 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

74 7411 741100 Plumbing Fixtures

Type : 63_ISR_inbouwreservoir_toilet 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

74 7411 741100 Plumbing Fixtures

Type : 450 (d) x 500 (b) 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

74 7411 741100 Generic Models

Type : douche 980 x 980 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

74 7411 741100 Plumbing Fixtures

Type : Duschsitz 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323121 Doors Type : H03 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323121 Doors Type : H04 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323121 Doors Type : H05 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

83 8310 831000 Furniture Type : HDL_opstelplaatsen 11 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

31 3120 312000 Windows Type : H06 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

31 3131 313121 Doors Type : glasdeur 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

83 8310 831000 Furniture Type : HDL_opstelplaatsen 7 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

83 8310 831000 Furniture Type : HDL_opstelplaatsen 25 STK

Page 70: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

68

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INPH01 Interior Process Hall

31 3131 313100 Curtain Panels

Type : deur 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2811 281121 Structural Columns

Type : HEA120 17 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

28 2811 281121 Structural Framing

Type : HEA120 13 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2811 281121 Structural Columns

Type : HEA120 6 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

28 2811 281121 Structural Framing

Type : HEA140 6 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

27 2721 272112 Floors Type : 300_27_staal_106R 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_glasvezel_beton 7 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

31 3111 311100 Generic Models

Type : glas 2 6 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_glasvezel_beton boven Rodeca wand

2 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_glasvezel_beton achter 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

28 2800 280000 Walls Type : 300_21_HSB_wand 12-90-12 iso 8 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

47 4721 472100 Floors Type : 300_23_isolatie_150mm afschot 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

43 4321 432111 Floors Type : 300_43_cementdekvloer_30 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4112 411251 Ceilings Type : 300_45_glasvezel_beton 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

21 2110 211000 Walls Type : 300_21_isolatie_90 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

31 3130 313000 Doors Type : redeca 1 STK

99 High Pressure Laboratory

ING01 Interior General

43 4300 430000 Floors Type : 200_43_afwerkvloer_60 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4110 411000 Generic Models

Type : std 1v 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

28 2800 280000 Walls Type : 300_21_HSB_wand 12-106-12 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

28 2800 280000 Walls Type : 300_21_HSB_wand 12-76-12 2 STK

Page 71: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

69

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Roofs Type : 200_27 isolatie 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Roofs Type : 200_27 isolatie tech ruimte 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_32_rooster_boven_kozijn 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

21 2110 211000 Walls Type : 300_21_kantplank 3 STK

99 High Pressure Laboratory

ING01 Interior General

0 0 0 Walls Type : 200_20_basis_100 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

28 2800 280000 Walls Type : 300_21_HSB_wand 12-76-12 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2811 281121 Structural Columns

Type : 20x70 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323121 Doors Type : lakdeur_stomp 9 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

45 4510 451000 Ceilings Type : 300_44_sauswerk_antraciet 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

45 4510 451000 Ceilings Type : 300_44_sauswerk_antraciet 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

45 4510 451000 Ceilings Type : 300_44_sauswerk_antraciet 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

45 4510 451000 Ceilings Type : 300_44_isolatie+Heraklith 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

45 4510 451000 Ceilings Type : 300_44_sauswerk_antraciet 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

45 4510 451000 Ceilings Type : 300_44_sauswerk_antraciet 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

45 4510 451000 Ceilings Type : 300_44_beplating+sauswerk_antraciet 4 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

45 4510 451000 Ceilings Type : 300_44_isolatie+Heraklith 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_dak_isolatie_nieuw 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

73 7311 731100 Furniture Systems

Type : met koken 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

47 4721 472100 Floors Type : 300_23_isolatie_100mm kouddak 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

47 4721 472100 Floors Type : 300_23_isolatie_100mm kouddak 1 STK

Page 72: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

70

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

21 2110 211000 Walls Type : 300_21_kantplank 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

45 4510 451000 Ceilings Type : 300_44_pir_Rc2,5 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

31 3131 313121 Doors Type : glasdeur 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

45 4510 451000 Ceilings Type : 300_44_akoestisch_1200x1200 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

43 4322 432236 Floors Type : 300_43_staptegels_300x300 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

43 4322 432236 Floors Type : 300_43_staptegels_300x300 10 STK

99 High Pressure Laboratory

ING01 Interior General

31 3131 313100 Curtain Panels

Type : deur 1 STK

99 High Pressure Laboratory

ING01 Interior General

31 3111 311100 Generic Models

Type : glas 2 2 STK

99 High Pressure Laboratory

ING01 Interior General

31 3130 313000 Doors Type : redeca 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4113 411300 Walls Type : 300_21_HSB wand proceshal 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Floors Type : 200_23_basisvloer_350mm 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Floors Type : 300_23_tussen_vloer_kantoor 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

32 3231 323121 Doors Type : H07 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_21_HSB_wand 12-76-12 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

32 3231 323121 Doors Type : H08 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

21 2111 211111 Walls Type : 300_21_metselwerk_100 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

28 2800 280000 Walls Type : 300_21_HSB_wand 12-135-12 iso 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Floors Type : 200_23_dak_isolatie_nieuw hoge druk 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Floors Type : 200_23_dak_isolatie_afschot 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_dak_isolatie_nieuw hoge druk 1 STK

Page 73: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

71

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_dak_isolatie_afschot 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2800 280000 Walls Type : 300_21_HSB_wand 12-135-12 iso 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Floors Type : 200_23_isolatie_stalen_balk 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

21 2110 211000 Walls Type : 300_21_isolatie_90 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4113 411300 Walls Type : 300_21_HSB wand proceshal kop 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

41 4112 411200 Walls Type : 300_41_beplating_12 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

41 4112 411200 Walls Type : 300_41_saus-oranje 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

32 3231 323100 Doors Type : H09 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

32 3231 323100 Doors Type : H09 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

32 3231 323121 Doors Type : deur met glas 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

43 4321 432100 Floors Type : 300_43_vloercoating_oranje 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

74 7411 741100 Plumbing Fixtures

Type : 74_ISR_urinoir 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

28 2811 281121 Structural Columns

Type : 20x70 20 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Framing

Type : HEA160 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Structural Framing

Type : Bout M20x250 8.8 DIN931 7 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Structural Framing

Type : Tapbout M12x120 8.8 DIN933 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Structural Framing

Type : Tapbout M12x120 8.8 DIN933 40 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

75 7510 751000 Plumbing Fixtures

Type : Mop_Sink_1577 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Columns

Type : K80x80x3 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Framing

Type : UNP140 4 STK

Page 74: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

72

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Framing

Type : HEA100 14 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Floors Type : 200_23_Dejo Rooster compressor ruimte

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Columns

Type : HEA200 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_21_HSB_wand 12-90-12 iso 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

28 2800 280000 Walls Type : 300_21_Heraklith WBDBO60min 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

22 2213 221300 Walls Type : 300_22_tussenwand_inloopbox 10 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4112 411200 Walls Type : 300_41_beplating_6 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4112 411200 Walls Type : 300_41_beplating_12 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

21 2110 211000 Walls Type : 300_21_isolatie hard_60 2 STK

99 High Pressure Laboratory

ING01 Interior General

45 4500 450000 Ceilings Type : 300_44_gipsvinyl_600x600 3 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2811 281121 Structural Framing

Type : IPE160 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2811 281121 Structural Framing

Type : HEA140 2 STK

99 High Pressure Laboratory

ING01 Interior General

23 2300 230000 Structural Beam Systems

Type : 300_28_balklaag 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

28 2811 281111 Structural Framing

Type : 71x246 11 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

21 2111 211111 Walls Type : 300_21_metselwerk_100 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

43 4322 432236 Floors Type : 300_43_staptegels_300x300 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

32 3231 323121 Doors Type : dubbele deur met glas 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

32 3231 323121 Doors Type : deur met glas antraciet 12 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

32 3231 323121 Doors Type : dubbele deur met glas 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

21 2123 212318 Walls Type : 300_21_HSB_38x38 8 STK

Page 75: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

73

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INPH01 Interior Process Hall

45 4500 450000 Ceilings Type : 300_44_gipsvinyl_600x600 1 STK

99 High Pressure Laboratory

ING01 Interior General

32 3231 323121 Doors Type : dubbele deur met glas 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

43 4322 432236 Floors Type : 300_43_staptegels_300x300 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

21 2111 211111 Walls Type : 300_21_metselwerk_100 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

28 2811 281121 Structural Framing

Type : HEA140 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

90 9010 901000 Floors Type : gras 1 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

90 9010 901000 Floors Type : gras 3 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

23 2300 230000 Floors Type : klinkers antraciet 1 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

21 2100 210000 Walls Type : _hedera_afscheiding 3 12 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

23 2300 230000 Floors Type : Sokkel compressor 800 x 1200 x 300 1 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

23 2300 230000 Floors Type : betonklinkers 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

23 2300 230000 Floors Type : stelcon plaat 11 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

23 2300 230000 Floors Type : stelcon plaat 3 STK

99 High Pressure Laboratory

SISB01 Side Building

23 2300 230000 Floors Type : stelcon plaat 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

23 2300 230000 Floors Type : stelcon plaat 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

23 2300 230000 Floors Type : betonklinkers 2 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

43 4322 432236 Floors Type : 300_43_staptegels_300x300 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

90 9000 900000 Planting Type : 5500_Golden Chain 1 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

90 9000 900000 Planting Type : 5500_Golden Chain 5 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

23 2300 230000 Floors Type : betonklinkers 3 STK

Page 76: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

74

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

23 2300 230000 Floors Type : grind 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

23 2300 230000 Floors Type : betonplaat 1 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

41 4112 411200 Walls Type : 300_41_beplating_techniek ruimtes 1200

1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_beplating_techniek ruimtes 1200

11 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_beplating_techniek ruimtes voor

3 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

23 2300 230000 Floors Type : betonklinkers 2 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

41 4112 411200 Walls Type : 300_99_beton_keerband 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

41 4112 411200 Walls Type : 300_99_beton_keerband 6 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

23 2300 230000 Floors Type : grind 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

41 4112 411200 Walls Type : 300_99_beton_keerband 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

23 2300 230000 Floors Type : stelcon plaat 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

23 2300 230000 Floors Type : grind 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

41 4112 411200 Walls Type : 300_99_beton_keerband 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

23 2300 230000 Floors Type : grind 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

43 4322 432236 Floors Type : 300_43_staptegels_300x300 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

45 4500 450000 Ceilings Type : 300_44_Rockfon Krios_600x600 1 STK

99 High Pressure Laboratory

ING01 Interior General

45 4500 450000 Ceilings Type : 300_44_Rockfon Krios_600x600 1 STK

99 High Pressure Laboratory

ING01 Interior General

45 4510 451000 Ceilings Type : 300_44_sauswerk_antraciet 1 STK

99 High Pressure Laboratory

ING01 Interior General

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 1 STK

99 High Pressure Laboratory

SISB01 Side Building

28 2800 280000 Walls Type : 300_28_betonsteen_210mm 15 STK

Page 77: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

75

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

SISB01 Side Building

23 2300 230000 Floors Type : betonklinkers 1 STK

99 High Pressure Laboratory

SISB01 Side Building

0 0 0 Floors Type : 200_23_basisvloer_100mm 1 STK

99 High Pressure Laboratory

SISB01 Side Building

31 3130 313000 Doors Type : 5std 4 STK

99 High Pressure Laboratory

SISB01 Side Building

31 3111 311100 Windows Type : glas 2 4 STK

99 High Pressure Laboratory

SISB01 Side Building

31 3141 314100 Windows Type : 31_paneel ver 6 STK

99 High Pressure Laboratory

SISB01 Side Building

0 0 0 Floors Type : 200_23_basisvloer_150mm 3 STK

99 High Pressure Laboratory

SISB01 Side Building

28 2811 281141 Structural Framing

Type : 150x300 4 STK

99 High Pressure Laboratory

SISB01 Side Building

41 4112 411200 Walls Type : 300_41_beplating_12 1 STK

99 High Pressure Laboratory

SISB01 Side Building

0 0 0 Roofs Type : 200_multiplex met bitumen 1 STK

99 High Pressure Laboratory

SISB01 Side Building

31 3141 314100 Windows Type : paneel ver 5 STK

99 High Pressure Laboratory

SISB01 Side Building

0 0 0 Floors Type : 200_23_hellingbaan 2 STK

99 High Pressure Laboratory

SISB01 Side Building

28 2811 281121 Structural Columns

Type : K60x60x3 7 STK

99 High Pressure Laboratory

SISB01 Side Building

41 4112 411200 Walls Type : 300_41_beplating_fietsenhok 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_beplating_fietsenhok 2 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

0 0 0 Floors Type : 200_23_dak_fietsenberging 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

41 4112 411200 Walls Type : 300_41_staalplaat_vertikaal 14 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

31 3141 314100 Windows Type : 31_paneel ver 1 STK

99 High Pressure Laboratory

EXEF01 Exterior Façade

31 3141 314100 Windows Type : paneel ver 2 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

23 2300 230000 Floors Type : betonplaat 4 STK

99 High Pressure Laboratory

EXET01 Exterior Terrain

0 0 0 Structural Framing

Type : Bout M20x250 8.8 DIN931 1 STK

Page 78: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

76

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INPH01 Interior Process Hall

31 3111 311100 Windows Type : glas 2 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Columns

Type : HEA140 16 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

28 2811 281121 Structural Framing

Type : HEA140 4 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

54 5411 541100 Pipes Type : Steel pipe Fe-35 539 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

54 5411 541100 Pipes Type : Steel pipe Fe-35 542 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

54 5411 541100 Pipes Type : Steel pipe Fe-35 124 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

54 5411 541100 Pipes Type : Steel pipe Fe-35 134 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

54 5411 541100 Pipes Type : Copper pipe 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Ducts Type : Ronde kanalen - T-stuk 86 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : 1 D 43 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Ducts Type : Ronde kanalen - Zadelstuk 39 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Ducts Type : Ronde kanalen - T-stuk 122 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Ducts Type : Rechte kanalen 7 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Ducts Type : Rechte kanalen 27 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Ducts Type : Rechte kanalen 5 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Ducts Type : Ronde kanalen - T-stuk 61 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Ducts Type : Ronde kanalen - T-stuk 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Ducts Type : Rechte kanalen 7 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Ducts Type : Rechte kanalen 4 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Fittings

Type : 30 gr 28 STK

Page 79: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

77

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Fittings

Type : 30 gr 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Air Terminals

Type : URH/A-125 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Air Terminals

Type : URH/A-100 5 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Ducts Type : Ronde kanalen - T-stuk 39 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Ducts Type : Ronde kanalen - Zadelstuk 33 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Fittings

Type : 1 D 31 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Ducts Type : Ronde kanalen - T-stuk 7 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Ducts Type : Ronde kanalen - T-stuk 23 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Ducts Type : Rechte kanalen 7 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Air Terminals

Type : URH/A-160 5 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Air Terminals

Type : URH/A-160 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Air Terminals

Type : circ-grille-315 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Ducts Type : Ronde kanalen - T-stuk 13 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Duct Fittings

Type : 30 gr 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Duct Fittings

Type : 1 D 7 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Air Terminals

Type : URH/A-125 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Air Terminals

Type : circ-grille-315 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Air Terminals

Type : circ-grille-250 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Fittings

Type : standaard 19 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Ducts Type : Ronde kanalen - T-stuk 43 STK

Page 80: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

78

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Fittings

Type : 1 D 20 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Fittings

Type : standaard 18 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Fittings

Type : 30 gr 7 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Air Terminals

Type : circ-grille-315 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Air Terminals

Type : KSO 200 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Fittings

Type : 1 D 7 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Ducts Type : Rechte kanalen 12 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Air Terminals

Type : URH/A-100 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Air Terminals

Type : URH/A-100 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Ducts Type : Ronde kanalen - T-stuk 12 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Ducts Type : Ronde kanalen - T-stuk 20 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Fittings

Type : standaard 12 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Ducts Type : Ronde kanalen - T-stuk 13 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Air Terminals

Type : URH/A-100 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Fittings

Type : standaard 28 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Air Terminals

Type : circ-grille-315 11 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Air Terminals

Type : URH/A-160 6 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Ducts Type : Ronde kanalen - T-stuk 48 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Fittings

Type : standaard 42 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Fittings

Type : 1 D 25 STK

Page 81: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

79

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : magirect_plug1_001 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Ducts Type : Ronde kanalen - Zadelstuk 7 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : magicirc_plug_001 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Air Terminals

Type : circ-grille-250 6 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Ducts Type : Rechte kanalen 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Fittings

Type : 1 D 21 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Ducts Type : Ronde kanalen - Zadelstuk 4 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : standaard 69 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : standaard 11 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : 1 D 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Air Terminals

Type : URH/A-160 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Fittings

Type : standaard 6 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Ducts Type : Ronde kanalen - Zadelstuk 10 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Fittings

Type : standaard 15 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Fittings

Type : 1 D 41 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Ducts Type : Ronde kanalen - T-stuk 65 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : standaard 11 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : 1 D 11 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : 30 gr 10 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Fittings

Type : 30 gr 26 STK

Page 82: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

80

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Ducts Type : Rechte kanalen 7 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Duct Fittings

Type : standaard 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Ducts Type : Rechte kanalen 22 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Ducts Type : Ronde kanalen - Zadelstuk 33 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Fittings

Type : 1 D 41 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Fittings

Type : 1 D 5 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5760 576000 Ducts Type : Ronde kanalen - T-stuk 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Fittings

Type : standaard 15 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Fittings

Type : 30 gr 25 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : 30 gr 19 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Air Terminals

Type : Terugslagklep 400x345 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Insulations

Type : Isolatie mineralewol 100mm 64 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Insulations

Type : Isolatie mineralewol 100mm 87 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Accessories

Type : S4R - Barcol Air, Demper isol 50 mm - met kern, L=500, 400-400

8 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Accessories

Type : S4R - Barcol Air, Demper isol 100 mm - met kern, L=500, 630-630

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Accessories

Type : S4R - Barcol Air, Demper isol 100 mm - met kern, L=500, 560-560

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Ducts Type : S4Rx_Generic_Rectangular 4 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Ducts Type : S4Rx_Generic_Rectangular 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : 45 Graden 12 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Accessories

Type : S4R - LUKA, Demper, L=1000, 800x800-800x800

1 STK

Page 83: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

81

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : LUKA, 90°, 600x600-800x600 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Ducts Type : S4Rx_Generic_Rectangular 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Ducts Type : S4Rx_Generic_Rectangular 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Insulations

Type : Isolatie mineralewol 100mm 11 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Ducts Type : S4R_Bergschenhoek_Spiro zaaglengte 3 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Air Terminals

Type : N/A, 100 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Flex Ducts Type : S4Rx_Generic_Round 3 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 160-160 5 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 125-125 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Ducts Type : S4R_LUKA_Verzinkt 3m 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-EU, 355-355

1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 100-100 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 100-100 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Air Terminals

Type : Muurrooster, 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Air Terminals

Type : N/A, 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

0 0 0 Air Terminals

Type : N/A, 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Ducts Type : Ronde kanalen - T-stuk 17 STK

Page 84: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

82

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Ducts Type : Ronde kanalen - Zadelstuk 19 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5740 574000 Duct Fittings

Type : 1 D 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Fittings

Type : 1 D 8 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Ducts Type : Rechte kanalen 6 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Ducts Type : Wandgoot 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Fittings

Type : magirect_plug1_001 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Ducts Type : Rechte kanalen 5 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 100-100 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Ducts Type : S4Rx_Generic_Round 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Ducts Type : Ronde kanalen - Zadelstuk 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Ducts Type : Ronde kanalen - Zadelstuk 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Insulations

Type : Isolatie mineralewol 100mm 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Insulations

Type : Isolatie mineralewol 100mm 16 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Insulations

Type : Isolatie mineralewol 100mm 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Duct Fittings

Type : 1 D 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Fittings

Type : magicirc_plug_001 13 STK

Page 85: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

83

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Fittings

Type : standaard 8 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : S4R_Saddle_Rectangular 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Insulations

Type : Isolatie mineralewol 100mm 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Fittings

Type : 1 D 8 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 160-160 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 160-160 5 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315 11 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Ducts Type : Ronde kanalen - T-stuk 16 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Ducts Type : Rechte kanalen 8 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Duct Insulations

Type : Isolatie mineralewol 100mm 5 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Fittings

Type : standaard 19 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Fittings

Type : 45 Graden 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Insulations

Type : Isolatie mineralewol 100mm 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Insulations

Type : Isolatie mineralewol 100mm 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Ducts Type : Rechte kanalen 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Fittings

Type : standaard 8 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Insulations

Type : Isolatie mineralewol 100mm 1 STK

Page 86: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

84

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Air Terminals

Type : circ-grille-200 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Air Terminals

Type : Terugslagklep 600x675 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400 16 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Ducts Type : Ronde kanalen - T-stuk 7 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

0 0 0 Duct Fittings

Type : LUKA, Recht zadel 90° 800, 2030x450-2030x450_e90e9e1b-1fbc-46d3-a176-da34db898d26

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Ducts Type : Rechte kanalen 5 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Duct Fittings

Type : LUKA, Recht zadel 90° 800, 2030x450-2030x450_e90e9e1b-1fbc-46d3-a176-da34db898d26

3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : S4R_Connection_Rectangular_AI_Generic

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : S4R_Connection_Rectangular_AI_Generic

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Duct Insulations

Type : Isolatie mineralewol 100mm 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Ducts Type : S4Rx_Generic_Rectangular 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Fittings

Type : LUKA, 90°, 520x600-800x600_44a9a3aa-7a68-45c3-b438-278707bacb89

1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Insulations

Type : Isolatie mineralewol 100mm 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Insulations

Type : Isolatie mineralewol 100mm 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Duct Accessories

Type : Filter_592x592x534 9 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Duct Accessories

Type : Filter_287x592x534 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Duct Accessories

Type : Filter_592x592x534 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Duct Accessories

Type : Filter_287x592x534 2 STK

Page 87: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

85

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Duct Accessories

Type : Atex Filter_292x592x535 LBK2 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Duct Accessories

Type : Atex Filter_490x592x535 LBK2 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Duct Accessories

Type : Atex Filter_292x592x535 LBK2 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Duct Accessories

Type : Filter_592x592x534 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Duct Accessories

Type : Filter_287x592x534 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Duct Accessories

Type : Filter_592x287x534 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Duct Accessories

Type : Filter_287x287x534 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Duct Accessories

Type : Filter_592x490x534 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Filter_892x490x534 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK9 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK8 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK7 8 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK6 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK5 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK4 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK2 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Ventilator LBK1 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Ducts Type : Rechte kanalen 4 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Insulations

Type : Isolatie mineralewol 100mm 2 STK

Page 88: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

86

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Fittings

Type : standaard 6 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Fittings

Type : With Flange 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Insulations

Type : Isolatie mineralewol 100mm 11 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Fittings

Type : S4R - LUKA, 90° scherp, 1220x800-750x800

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Fittings

Type : 45 Graden 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Ducts Type : Rechte kanalen 8 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Duct Fittings

Type : standaard 6 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Ducts Type : Ronde kanalen - Zadelstuk 8 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Duct Fittings

Type : 1 D 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

5 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Air Terminals

Type : circ-grille-315 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

4 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Ducts Type : Rechte kanalen 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 250-250

1 STK

Page 89: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

87

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Ducts Type : Ronde kanalen - Zadelstuk 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Fittings

Type : 30 gr 9 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_4d0dda9b-4f74-47d6-9de4-41f39c10c1fb

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 200-200_61a15fa6-babd-4bc3-975c-cf43baf875fc

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_9c5e0bfa-2637-46b1-86e2-f500476c25a5

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : Bergschenhoek, Verbinding hulpstuk, 250-250_83af97c1-56f1-4dd9-8c83-a9dcdb78a9bb

3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_9c5e0bfa-2637-46b1-86e2-f500476c25a5

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Ducts Type : Ronde kanalen - Zadelstuk 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, RECT, 300x200-300x200 TVJ

1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 200-200

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Air Terminals

Type : Adapter, 248 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Air Terminals

Type : Kanaalrooster standaard, 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Fittings

Type : standaard 4 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Air Terminals

Type : Kanaalrooster standaard, 5 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Air Terminals

Type : Kanaalrooster standaard, 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Air Terminals

Type : Adapter, 248 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Ducts Type : Ronde kanalen - Zadelstuk 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Fittings

Type : 30 gr 6 STK

Page 90: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

88

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 200-200

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Fittings

Type : 1 D 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 315-315

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RND Standaard, 200-200

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Air Terminals

Type : Muurrooster, 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

6 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Ducts Type : Ronde kanalen - T-stuk 15 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Fittings

Type : 1 D 11 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Air Terminals

Type : Kanaalrooster standaard, 22 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Ducts Type : Ronde kanalen - T-stuk 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Air Terminals

Type : Kanaalrooster standaard, 5 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Duct Fittings

Type : magicirc_plug_001 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Duct Fittings

Type : magicirc_plug_001 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Air Terminals

Type : Kanaalrooster standaard, 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Fittings

Type : magicirc_plug_001 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Air Terminals

Type : Kanaalrooster standaard, 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Air Terminals

Type : Standaard, 315 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Air Terminals

Type : Standaard, 315 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Air Terminals

Type : Adapter, 250 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Air Terminals

Type : Adapter, 250 1 STK

Page 91: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

89

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-EU, 355-355

2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-EU, 355-355

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Ducts Type : Ronde kanalen - Zadelstuk 4 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5740 574000 Air Terminals

Type : Adapter, 250 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5740 574000 Ducts Type : Ronde kanalen - T-stuk 7 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Air Terminals

Type : Plenumbox, 398-398-398-398 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Air Terminals

Type : Kanaalrooster deflector, 4 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, MSA 100, L=1000, 800x900-800x900_225060a9-1187-4e77-adb8-f0a87ccf79ea

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Fittings

Type : LUKA, 90°, 900x900-800x900_969b0726-70d7-4bdb-8798-796d66ca733e

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, MSA 200, L=500, 1600x800-1600x800_97464c76-7b4a-4678-8cca-7c59f1454f9d

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, CA100, L=1000, 315-315 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Fittings

Type : 30 gr 7 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, CA100, L=1000, 400-400 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Duct Fittings

Type : 30 gr 3 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Air Terminals

Type : circ-grille-200 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Air Terminals

Type : circ-grille-250 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_9c5e0bfa-2637-46b1-86e2-f500476c25a5

2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Fittings

Type : LUKA, Centrisch, 580x1220-600x600_2c91db91-f9a9-43ca-9ba4-22e975320ef9

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Flex Ducts Type : S4Rx_Generic_Round 1 STK

Page 92: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

90

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5750 575000 Ducts Type : S4Rx_Generic_Rectangular 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Fittings

Type : 1 D 6 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Ducts Type : Ronde kanalen - Zadelstuk 4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 125-125 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Fittings

Type : 30 gr 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5740 574000 Ducts Type : Ronde kanalen - Zadelstuk 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Duct Accessories

Type : S4R - Barcol Air, Demper isol 100 mm - met kern, L=500, 400-400_419449e0-3ab1-4d99-91be-f089dbb08b56

2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, Brandklep FKRS-EU, 250-250

2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, CA050, L=1000, 250-250_833693a7-a50e-4325-b431-c64ea1d76390

2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Ducts Type : Ronde kanalen - Zadelstuk 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Air Terminals

Type : Standaard, 250 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-06-TB L= 370, 400-400_2010d30f-06e9-4114-8ef3-673b4cceceff

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Air Terminals

Type : S4R_Terminal_Wall_IN 5 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Ducts Type : S4Rx_Generic_Rectangular 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Fittings

Type : With Flange 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Ducts Type : S4Rx_Generic_Rectangular 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Air Terminals

Type : circ-grille-315 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Air Terminals

Type : circ-grille-315 14 STK

Page 93: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

91

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Air Terminals

Type : PRIMO Model 550 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Air Terminals

Type : N/A, 100 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Air Terminals

Type : N/A, 100 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 125-125 1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5740 574000 Duct Fittings

Type : standaard 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR Compact

4 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Fittings

Type : 30 gr 7 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Air Terminals

Type : N/A, 100 5 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR

2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Air Terminals

Type : N/A, 100 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Air Terminals

Type : N/A, 100 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 80-80

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : 30 gr 2 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Ducts Type : Rechte kanalen 5 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5740 574000 Ducts Type : Ronde kanalen - Zadelstuk 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Vlinderklep, 250-250 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250 5 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Pipe Fittings

Type : S4R - Keaser, Keaser-SM-12T__2dcecc4424fe_42f5_5bee_7d352dcecc44

1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Fittings

Type : LUKA, Recht zadel 90°, 1000x500-1000x500

1 STK

Page 94: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

92

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5730 573000 Duct Fittings

Type : LUKA, Recht zadel 90°, 1000x500-1000x500

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5730 573000 Ducts Type : S4Rx_Generic_Rectangular 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Fittings

Type : 30 gr 9 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Air Terminals

Type : URH/A-100 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315 6 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Air Terminals

Type : Adapter, 125_a518c2a8-a608-454f-b48e-fe17e2e5d6ad

1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Air Terminals

Type : S4R_Terminal_Wall_IN 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Air Terminals

Type : Standaard, 315_c70003b8-1316-4c1d-9b3c-6cf4626b161d

1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5740 574000 Duct Fittings

Type : 30 gr 5 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 200-200

1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Duct Fittings

Type : 30 gr 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Air Terminals

Type : Adapter, 125_a518c2a8-a608-454f-b48e-fe17e2e5d6ad

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Air Terminals

Type : N/A, 200 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

0 0 0 Air Terminals

Type : S4R_Terminal_Wall_IN 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 200-200

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 160-160

2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 315-315

1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Air Terminals

Type : Plenumbox, 315-315-315-315 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5750 575000 Flex Ducts Type : S4Rx_Generic_Round 2 STK

Page 95: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

93

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 315-315

3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Air Terminals

Type : Plenumbox, 315-315-315-315 2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Flex Ducts Type : S4Rx_Generic_Round 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 125-125

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 125-125

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

0 0 0 Air Terminals

Type : S4R_Terminal_Wall_IN 2 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, Brandklep FKRS-EU, 250-250

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, CA050, L=1000, 250-250_833693a7-a50e-4325-b431-c64ea1d76390

1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

0 0 0 Air Terminals

Type : Standaard, 4 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5750 575000 Air Terminals

Type : Standaard, 200 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Ducts Type : S4Rx_Generic_Round 3 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : S4R_Reducer_Round_AI_Generic 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5750 575000 Air Terminals

Type : Standaard, 200 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Ducts Type : S4Rx_Generic_Round 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : S4R_Reducer_Round_AI_Generic 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5750 575000 Duct Accessories

Type : S4R - Trox Air, RECT, 400x200-400x200 TVJ

1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, TVR Compact, 250-250 TVR Compact1

1 STK

Page 96: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

94

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5730 573000 Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR Compact

2 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, MSA 100, L=500, 600x600-600x600_e62c6a59-e7a3-416e-8807-3ef279c3baef

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Ducts Type : Rechte kanalen 2 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Duct Fittings

Type : standaard 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Insulations

Type : Isolatie mineralewol 100mm 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5740 574000 Ducts Type : S4R_LUKA_Verzinkt 3m 10 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Atex Filter_292x592x535 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Atex Filter_490x592x535 2 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Atex Filter_490x592x535 LBK2 7 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

0 0 0 Duct Accessories

Type : Atex Filter_292x592x535 LBK2 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Ducts Type : S4R_Burgerhout_Afvoerpijp l=250 55 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, AKK, 160-160 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 100-100

1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 100-100

1 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

0 0 0 Air Terminals

Type : Overdruk Jalouziklep 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Air Terminals

Type : Overdruk Jalouziklep 3 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Air Terminals

Type : SPR 2030x450x275 4 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315 3 STK

99 High Pressure Laboratory

INMA01 Interior Mounting Area

57 5720 572000 Ducts Type : S4R_Burgerhout_Afvoerpijp l=250 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Duct Fittings

Type : 30 Graden 1 STK

Page 97: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

95

Bu

ildin

g C

od

e

Bu

ildin

g D

escr

ipti

on

Spac

e C

od

e

Spac

e D

escr

ipti

on

Key

ele

men

t co

de

Elem

ent

Co

de

Sub

Ele

men

t C

od

e

Co

mp

on

ent

Des

crip

tio

n

Typ

e

Qu

anti

ty

Un

it

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Fittings

Type : 30 Graden 14 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 10 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Fittings

Type : S4R_Tee_Round_AI_Generic 8 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Ducts Type : S4R_Burgerhout_Afvoerpijp l=250 3 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Fittings

Type : 30 Graden 1 STK

99 High Pressure Laboratory

INPH01 Interior Process Hall

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400 1 STK

99 High Pressure Laboratory

INCA01 Interior Common Area

57 5720 572000 Ducts Type : S4R_Burgerhout_Afvoerpijp l=250 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Air Terminals

Type : circ-grille-200 7 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315 21 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Ducts Type : S4R_Burgerhout_Afvoerpijp l=250 6 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5720 572000 Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK

99 High Pressure Laboratory

INBL01 Interior Box Laboratory

57 5740 574000 Ducts Type : S4R_Burgerhout_Afvoerpijp l=250 1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

0 0 0 Duct Accessories

Type : S4R - Barcol Air, Demper coul.100 L=1000, L=1000, 600x1000-600x1000

1 STK

99 High Pressure Laboratory

EXER01 Exterior Roof

57 5720 572000 Duct Accessories

Type : S4R - Trox Air, MSA 100, L=500, 500x1000-500x1000_a8ae5a6c-d983-4898-ab0d-e589edf2c9b2

1 STK

Page 98: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

96

APPENDIX E

TRANSFERRED BUILDING DATA COMPONENT RESULT

Page 99: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

97

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXEF01

Exterior Façade

Floors Type : 200_23_dak_fietsenberging 1 STK 230 263 319 10929 111043

99 High Pressure Laboratory

EXEF01

Exterior Façade

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_100 52 STK 230 263 319 10929 110833

99 High Pressure Laboratory

EXEF01

Exterior Façade

22 Binnenwanden

2221 Constructief, massieve wanden

222141 Walls Type : 300_22_ihw beton_100 4 STK 230 263 319 10929 110859

99 High Pressure Laboratory

EXEF01

Exterior Façade

22 Binnenwanden

2221 Constructief, massieve wanden

222141 Walls Type : 300_22_ihw beton_210 40 STK 230 263 319 10929 110864

99 High Pressure Laboratory

EXEF01

Exterior Façade

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonklinkers 2 STK 230 263 319 10929 111014

99 High Pressure Laboratory

EXEF01

Exterior Façade

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 11 STK 230 263 319 10929 110855

99 High Pressure Laboratory

EXEF01

Exterior Façade

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_beton_ihwg_400mm 3 STK 230 263 319 10929 110863

99 High Pressure Laboratory

EXEF01

Exterior Façade

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-76-12 2 STK 230 263 319 10929 110914

99 High Pressure Laboratory

EXEF01

Exterior Façade

31 Buitenwandopeningen

3141 Gevuld met puien, gesloten puien

314100 Gevuld met puien, gesloten puien, Algemeen

Windows Type : 31_paneel ver 1 STK 230 263 319 10929 111045

99 High Pressure Laboratory

EXEF01

Exterior Façade

31 Buitenwandopeningen

3141 Gevuld met puien, gesloten puien

314100 Gevuld met puien, gesloten puien, Algemeen

Windows Type : paneel ver 2 STK 230 263 319 10929 111046

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_glasvezel_beton 7 STK 230 263 319 10929 110895

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_glasvezel_beton boven Rodeca wand

2 STK 230 263 319 10929 110897

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_glasvezel_beton achter 3 STK 230 263 319 10929 110898

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_techniek ruimtes 1200

11 STK 230 263 319 10929 111012

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_techniek ruimtes voor

3 STK 230 263 319 10929 111013

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_fietsenhok 2 STK 230 263 319 10929 111042

99 High Pressure Laboratory

EXEF01

Exterior Façade

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_staalplaat_vertikaal 14 STK 230 263 319 10929 111044

Page 100: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

98

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_basisvloer_200mm 3 STK 230 263 319 10931 110856

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_basisvloer_150mm 1 STK 230 263 319 10931 110857

99 High Pressure Laboratory

EXER01

Exterior Roof

Walls Type : 200_23_ventilatieopbouw_dak 7 STK 230 263 319 10931 110858

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_basisvloer_80mm 2 STK 230 263 319 10931 110861

99 High Pressure Laboratory

EXER01

Exterior Roof

Roofs Type : 200_27 isolatie 1 STK 230 263 319 10931 110909

99 High Pressure Laboratory

EXER01

Exterior Roof

Roofs Type : 200_27 isolatie tech ruimte 1 STK 230 263 319 10931 110910

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_dak_isolatie_nieuw 2 STK 230 263 319 10931 110925

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_dak_isolatie_nieuw hoge druk

1 STK 230 263 319 10931 110948

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_dak_isolatie_afschot 1 STK 230 263 319 10931 110949

99 High Pressure Laboratory

EXER01

Exterior Roof

Floors Type : 200_23_isolatie_stalen_balk 1 STK 230 263 319 10931 110951

99 High Pressure Laboratory

EXER01

Exterior Roof

Duct Fittings

Type : LUKA, Recht zadel 90° 800, 2030x450-2030x450_e90e9e1b-1fbc-46d3-a176-da34db898d26

3 STK 230 263 319 10931 111216

99 High Pressure Laboratory

EXER01

Exterior Roof

Duct Accessories

Type : Filter_592x592x534 9 STK 230 263 319 10931 111225

99 High Pressure Laboratory

EXER01

Exterior Roof

Duct Accessories

Type : Filter_287x592x534 2 STK 230 263 319 10931 111226

99 High Pressure Laboratory

EXER01

Exterior Roof

Duct Accessories

Type : Filter_287x287x534 1 STK 230 263 319 10931 111235

99 High Pressure Laboratory

EXER01

Exterior Roof

Duct Accessories

Type : Filter_592x490x534 8 STK 230 263 319 10931 111236

99 High Pressure Laboratory

EXER01

Exterior Roof

Air Terminals

Type : Standaard, 250 1 STK 230 263 319 10931 111340

99 High Pressure Laboratory

EXER01

Exterior Roof

Air Terminals

Type : S4R_Terminal_Wall_IN 5 STK 230 263 319 10931 111343

Page 101: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

99

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

Ducts Type : Rechte kanalen 5 STK 230 263 319 10931 111363

99 High Pressure Laboratory

EXER01

Exterior Roof

Air Terminals

Type : Overdruk Jalouziklep 3 STK 230 263 319 10931 111424

99 High Pressure Laboratory

EXER01

Exterior Roof

Air Terminals

Type : SPR 2030x450x275 4 STK 230 263 319 10931 111425

99 High Pressure Laboratory

EXER01

Exterior Roof

Duct Accessories

Type : S4R - Barcol Air, Demper coul.100 L=1000, L=1000, 600x1000-600x1000

1 STK 230 263 319 10931 111442

99 High Pressure Laboratory

EXER01

Exterior Roof

27 Daken 2721 constructief, vlakke daken

272112 Floors Type : 300_27_staal_106R 1 STK 230 263 319 10931 110894

99 High Pressure Laboratory

EXER01

Exterior Roof

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 2 STK 230 263 319 10931 110870

99 High Pressure Laboratory

EXER01

Exterior Roof

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-106-12 2 STK 230 263 319 10931 110907

99 High Pressure Laboratory

EXER01

Exterior Roof

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-76-12 2 STK 230 263 319 10931 110908

99 High Pressure Laboratory

EXER01

Exterior Roof

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-135-12 iso

1 STK 230 263 319 10931 110945

99 High Pressure Laboratory

EXER01

Exterior Roof

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA120 13 STK 230 263 319 10931 110891

99 High Pressure Laboratory

EXER01

Exterior Roof

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA140 6 STK 230 263 319 10931 110893

99 High Pressure Laboratory

EXER01

Exterior Roof

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : dubbele deur met glas 2 STK 230 263 319 10931 110985

99 High Pressure Laboratory

EXER01

Exterior Roof

43 Vloerafwerkingen

4322 Verhoogde vloer 432236 Floors Type : 300_43_staptegels_300x300 10 STK 230 263 319 10931 110934

99 High Pressure Laboratory

EXER01

Exterior Roof

45 Plafondafwerkingen

4500 Plafondafwerkingen algemeen

450000 Plafondafwerkingen, algemeen

Ceilings Type : 300_44_Rockfon Krios_600x600

1 STK 230 263 319 10931 111024

99 High Pressure Laboratory

EXER01

Exterior Roof

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_sauswerk_antraciet 1 STK 230 263 319 10931 110917

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 61 STK 230 263 319 10931 111064

Page 102: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

100

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 28 STK 230 263 319 10931 111068

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 1 STK 230 263 319 10931 111113

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 21 STK 230 263 319 10931 111114

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 4 STK 230 263 319 10931 111115

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 15 STK 230 263 319 10931 111136

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 2 STK 230 263 319 10931 111146

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 1 STK 230 263 319 10931 111208

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-200 1 STK 230 263 319 10931 111209

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400

16 STK 230 263 319 10931 111211

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=1000, 400-400

1 STK 230 263 319 10931 111322

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Brandklep FKRS-EU, 250-250

2 STK 230 263 319 10931 111337

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA050, L=1000, 250-250_833693a7-a50e-4325-b431-c64ea1d76390

2 STK 230 263 319 10931 111338

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-06-TB L= 370, 400-400_2010d30f-06e9-4114-8ef3-673b4cceceff

1 STK 230 263 319 10931 111342

Page 103: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

101

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Vlinderklep, 250-250

1 STK 230 263 319 10931 111365

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_Burgerhout_Afvoerpijp l=250

55 STK 230 263 319 10931 111419

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, AKK, 160-160 1 STK 230 263 319 10931 111420

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 100-100

1 STK 230 263 319 10931 111421

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315

3 STK 230 263 319 10931 111426

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 Graden 14 STK 230 263 319 10931 111429

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 10 STK 230 263 319 10931 111430

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Tee_Round_AI_Generic 8 STK 230 263 319 10931 111431

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, MSA 100, L=500, 500x1000-500x1000_a8ae5a6c-d983-4898-ab0d-e589edf2c9b2

1 STK 230 263 319 10931 111443

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 2 STK 230 263 319 10931 111069

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 17 STK 230 263 319 10931 111168

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 4 STK 230 263 319 10931 111184

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 8 STK 230 263 319 10931 111189

Page 104: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

102

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 8 STK 230 263 319 10931 111195

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 160-160

1 STK 230 263 319 10931 111196

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 8 STK 230 263 319 10931 111200

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

1 STK 230 263 319 10931 111262

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 1 STK 230 263 319 10931 111339

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 2 STK 230 263 319 10931 111344

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 1 STK 230 263 319 10931 111345

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : LUKA, Recht zadel 90°, 1000x500-1000x500

1 STK 230 263 319 10931 111369

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - T-stuk 86 STK 230 263 319 10931 111057

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 1 D 43 STK 230 263 319 10931 111058

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - Zadelstuk 39 STK 230 263 319 10931 111059

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Rechte kanalen 7 STK 230 263 319 10931 111061

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : magirect_plug1_001 2 STK 230 263 319 10931 111109

Page 105: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

103

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : standaard 69 STK 230 263 319 10931 111116

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 30 gr 19 STK 230 263 319 10931 111138

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Terugslagklep 400x345 8 STK 230 263 319 10931 111139

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Insulations

Type : Isolatie mineralewol 100mm 87 STK 230 263 319 10931 111141

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - Barcol Air, Demper isol 50 mm - met kern, L=500, 400-400

8 STK 230 263 319 10931 111142

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - Barcol Air, Demper isol 100 mm - met kern, L=500, 630-630

1 STK 230 263 319 10931 111143

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - Barcol Air, Demper isol 100 mm - met kern, L=500, 560-560

1 STK 230 263 319 10931 111144

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : S4Rx_Generic_Rectangular 4 STK 230 263 319 10931 111145

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 45 Graden 12 STK 230 263 319 10931 111147

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - LUKA, Demper, L=1000, 800x800-800x800

1 STK 230 263 319 10931 111148

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : With Flange 1 STK 230 263 319 10931 111149

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : LUKA, 90°, 600x600-800x600 1 STK 230 263 319 10931 111150

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Kanaalrooster standaard, 1 STK 230 263 319 10931 111302

Page 106: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

104

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : magicirc_plug_001 1 STK 230 263 319 10931 111303

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400

1 STK 230 263 319 10931 111334

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - Barcol Air, Demper isol 100 mm - met kern, L=500, 400-400_419449e0-3ab1-4d99-91be-f089dbb08b56

2 STK 230 263 319 10931 111336

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : S4R_LUKA_Verzinkt 3m 10 STK 230 263 319 10931 111414

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 4 STK 230 263 319 10931 111065

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : magicirc_plug_001 2 STK 230 263 319 10931 111111

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 11 STK 230 263 319 10931 111117

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 4 STK 230 263 319 10931 111118

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 1 STK 230 263 319 10931 111151

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 5 STK 230 263 319 10931 111215

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Connection_Rectangular_AI_Generic

1 STK 230 263 319 10931 111218

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 2 STK 230 263 319 10931 111224

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-EU, 355-355

1 STK 230 263 319 10931 111311

Page 107: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

105

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 4 STK 230 263 319 10931 111312

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

1 STK 230 263 319 10931 111341

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 2 STK 230 263 319 10931 111362

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Round 3 STK 230 263 319 10931 111404

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Reducer_Round_AI_Generic

1 STK 230 263 319 10931 111405

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK 230 263 319 10931 111406

99 High Pressure Laboratory

EXER01

Exterior Roof

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, RECT, 400x200-400x200 TVJ

1 STK 230 263 319 10931 111407

99 High Pressure Laboratory

EXER01

Exterior Roof

90 Terrein 9010 Grondvoorzieningen, algemeen (verzamelniveau)

901000

Grondvoorzieningen, algemeen (verzamelniveau), Onbepaald

Floors Type : gras 1 STK 230 263 319 10931 110994

99 High Pressure Laboratory

EXET01

Exterior Terrain

Structural Framing

Type : Bout M20x250 8.8 DIN931 1 STK 230 263 319 10933 111048

99 High Pressure Laboratory

EXET01

Exterior Terrain

21 Buitenwanden

2100 Buitenwanden algemeen

210000 Buitenwanden, algemeen Walls Type : _hedera_afscheiding 3 12 STK 230 263 319 10933 110997

99 High Pressure Laboratory

EXET01

Exterior Terrain

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : klinkers antraciet 1 STK 230 263 319 10933 110996

99 High Pressure Laboratory

EXET01

Exterior Terrain

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : Sokkel compressor 800 x 1200 x 300

1 STK 230 263 319 10933 110998

99 High Pressure Laboratory

EXET01

Exterior Terrain

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonklinkers 8 STK 230 263 319 10933 110999

99 High Pressure Laboratory

EXET01

Exterior Terrain

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : stelcon plaat 3 STK 230 263 319 10933 111001

Page 108: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

106

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

EXET01

Exterior Terrain

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : grind 4 STK 230 263 319 10933 111017

99 High Pressure Laboratory

EXET01

Exterior Terrain

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonplaat 4 STK 230 263 319 10933 111047

99 High Pressure Laboratory

EXET01

Exterior Terrain

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_techniek ruimtes 1200

1 STK 230 263 319 10933 111011

99 High Pressure Laboratory

EXET01

Exterior Terrain

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_99_beton_keerband 3 STK 230 263 319 10933 111015

99 High Pressure Laboratory

EXET01

Exterior Terrain

43 Vloerafwerkingen

4322 Verhoogde vloer 432236 Floors Type : 300_43_staptegels_300x300 1 STK 230 263 319 10933 111005

99 High Pressure Laboratory

EXET01

Exterior Terrain

90 Terrein 9000 Terreinvoorzieningen 900000 Terrein voorzieningen Planting Type : 5500_Golden Chain 5 STK 230 263 319 10933 111007

99 High Pressure Laboratory

EXET01

Exterior Terrain

90 Terrein 9010 Grondvoorzieningen, algemeen (verzamelniveau)

901000

Grondvoorzieningen, algemeen (verzamelniveau), Onbepaald

Floors Type : 200_99_terrein 1 STK 230 263 319 10933 110867

99 High Pressure Laboratory

EXET01

Exterior Terrain

90 Terrein 9010 Grondvoorzieningen, algemeen (verzamelniveau)

901000

Grondvoorzieningen, algemeen (verzamelniveau), Onbepaald

Floors Type : gras 3 STK 230 263 319 10933 110995

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Floors Type : 200_23_basisvloer_200mm 1 STK 230 263 319 10930 110848

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Floors Type : 200_23_basisvloer_350mm 1 STK 230 263 319 10930 110939

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Floors Type : 300_23_tussen_vloer_kantoor 1 STK 230 263 319 10930 110940

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Floors Type : 200_23_dak_isolatie_nieuw hoge druk

1 STK 230 263 319 10930 110946

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Floors Type : 200_23_dak_isolatie_afschot 1 STK 230 263 319 10930 110947

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Floors Type : 200_23_Dejo Rooster compressor ruimte

1 STK 230 263 319 10930 110970

Page 109: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

107

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Filter_892x490x534 1 STK 230 263 319 10930 111237

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK9 2 STK 230 263 319 10930 111238

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK8 1 STK 230 263 319 10930 111239

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK7 8 STK 230 263 319 10930 111240

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK6 1 STK 230 263 319 10930 111241

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK5 1 STK 230 263 319 10930 111242

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK4 2 STK 230 263 319 10930 111243

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK2 2 STK 230 263 319 10930 111244

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Ventilator LBK1 2 STK 230 263 319 10930 111245

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Air Terminals

Type : URH/A-100 1 STK 230 263 319 10930 111372

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Air Terminals

Type : Adapter, 125_a518c2a8-a608-454f-b48e-fe17e2e5d6ad

1 STK 230 263 319 10930 111374

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Air Terminals

Type : S4R_Terminal_Wall_IN 2 STK 230 263 319 10930 111375

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Atex Filter_292x592x535 1 STK 230 263 319 10930 111415

Page 110: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

108

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Atex Filter_490x592x535 2 STK 230 263 319 10930 111416

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Atex Filter_490x592x535 LBK2 7 STK 230 263 319 10930 111417

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

Duct Accessories

Type : Atex Filter_292x592x535 LBK2 1 STK 230 263 319 10930 111418

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

21 Buitenwanden

2110 Niet constructief, algemeen (verzamelniveau)

211000 Niet constructief, algemeen (verzamelniveau), Algemeen

Walls Type : 300_21_isolatie_90 3 STK 230 263 319 10930 110952

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_100 1 STK 230 263 319 10930 110992

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : stelcon plaat 11 STK 230 263 319 10930 111000

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonklinkers 3 STK 230 263 319 10930 111008

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : grind 8 STK 230 263 319 10930 111009

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonplaat 1 STK 230 263 319 10930 111010

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

23 Vloeren 2321 constructief, vrijdragende vloeren

232142 Floors Type : 300_23_betonvloer_200 8 STK 230 263 319 10930 110843

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_beton_ihwg_400mm 53 STK 230 263 319 10930 110840

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_100mm 8 STK 230 263 319 10930 110841

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_22_drijfsteen_100mm 60 STK 230 263 319 10930 110842

Page 111: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

109

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_beton_ihwg_280mm 8 STK 230 263 319 10930 110847

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-135-12 iso

1 STK 230 263 319 10930 110950

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA160 2 STK 230 263 319 10930 110962

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : K80x80x3 1 STK 230 263 319 10930 110967

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : UNP140 4 STK 230 263 319 10930 110968

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA100 14 STK 230 263 319 10930 110969

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : HEA200 4 STK 230 263 319 10930 110971

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : HEA140 16 STK 230 263 319 10930 111050

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA140 4 STK 230 263 319 10930 111051

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

32 Binnenwandopeningen

3230 Gevuld met deuren, algemeen (verzamelniveau)

323000

Gevuld met deuren, algemeen (verzamelniveau), Algemeen

Doors Type : rozet 20 STK 230 263 319 10930 110846

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323100 Gevuld met deuren, draaideuren, Draaideuren

Doors Type : dagmaat 0850x2000 10 STK 230 263 319 10930 110845

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : deur met glas 4 STK 230 263 319 10930 110958

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

43 Vloerafwerkingen

4300 Vloerafwerkingen 430000 Vloerafwerking, algemeen Floors Type : 200_43_afwerkvloer_150 9 STK 230 263 319 10930 110869

Page 112: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

110

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

43 Vloerafwerkingen

4322 Verhoogde vloer 432236 Floors Type : 300_43_staptegels_300x300 1 STK 230 263 319 10930 110991

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_sauswerk_antraciet 1 STK 230 263 319 10930 110921

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_beplating+sauswerk_antraciet

4 STK 230 263 319 10930 110923

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_isolatie+Heraklith 1 STK 230 263 319 10930 110924

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

47 Dakafwerkingen

4710 Afwerkingen, algemeen (verzamelniveau)

471000 Afwerkingen, algemeen (verzamelniveau), Algemeen

Floors Type : 300_43_heraklith_50mm 8 STK 230 263 319 10930 110844

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

47 Dakafwerkingen

4721 Bekledingen, vlakke dak bekledingen

472100 Bekledingen, vlakke dak bekledingen, Algemeen

Floors Type : 300_23_isolatie_100mm kouddak

1 STK 230 263 319 10930 110927

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

54 Gassen 5411 Brandstof, aardgasvoorziening

541100 Brandstof, aardgasvoorziening, Algemeen

Pipes Type : Steel pipe Fe-35 539 STK 230 263 319 10930 111052

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

54 Gassen 5411 Brandstof, aardgasvoorziening

541100 Brandstof, aardgasvoorziening, Algemeen

Pipes Type : Copper pipe 3 STK 230 263 319 10930 111056

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 122 STK 230 263 319 10930 111060

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 5 STK 230 263 319 10930 111063

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-100 3 STK 230 263 319 10930 111102

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 28 STK 230 263 319 10930 111103

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 7 STK 230 263 319 10930 111110

Page 113: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

111

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-250 6 STK 230 263 319 10930 111112

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 41 STK 230 263 319 10930 111123

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 100-100

4 STK 230 263 319 10930 111177

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400

1 STK 230 263 319 10930 111212

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : LUKA, Centrisch, 580x1220-600x600_2c91db91-f9a9-43ca-9ba4-22e975320ef9

1 STK 230 263 319 10930 111327

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 14 STK 230 263 319 10930 111348

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 125-125

1 STK 230 263 319 10930 111352

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : N/A, 100 5 STK 230 263 319 10930 111356

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 9 STK 230 263 319 10930 111371

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-200 7 STK 230 263 319 10930 111437

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315

21 STK 230 263 319 10930 111438

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_Burgerhout_Afvoerpijp l=250

6 STK 230 263 319 10930 111439

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK 230 263 319 10930 111440

Page 114: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

112

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 2 STK 230 263 319 10930 111183

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 4 STK 230 263 319 10930 111246

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK 230 263 319 10930 111247

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 2 STK 230 263 319 10930 111248

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 1 STK 230 263 319 10930 111249

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 6 STK 230 263 319 10930 111250

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 2 STK 230 263 319 10930 111261

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Kanaalrooster standaard, 1 STK 230 263 319 10930 111285

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RND Standaard, 200-200

1 STK 230 263 319 10930 111292

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

6 STK 230 263 319 10930 111294

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 15 STK 230 263 319 10930 111295

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 11 STK 230 263 319 10930 111296

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 3 STK 230 263 319 10930 111323

Page 115: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

113

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-200 1 STK 230 263 319 10930 111324

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-250 1 STK 230 263 319 10930 111325

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : N/A, 100 1 STK 230 263 319 10930 111351

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 1 STK 230 263 319 10930 111370

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Rechte kanalen 27 STK 230 263 319 10930 111062

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - T-stuk 65 STK 230 263 319 10930 111124

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 1 D 41 STK 230 263 319 10930 111133

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 30 gr 25 STK 230 263 319 10930 111137

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Insulations

Type : Isolatie mineralewol 100mm 64 STK 230 263 319 10930 111140

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250

3 STK 230 263 319 10930 111180

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - Zadelstuk 3 STK 230 263 319 10930 111181

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400

1 STK 230 263 319 10930 111182

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : magicirc_plug_001 13 STK 230 263 319 10930 111188

Page 116: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

114

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : standaard 19 STK 230 263 319 10930 111202

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Terugslagklep 600x675 1 STK 230 263 319 10930 111210

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Kanaalrooster standaard, 22 STK 230 263 319 10930 111297

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315

6 STK 230 263 319 10930 111373

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Standaard, 315_c70003b8-1316-4c1d-9b3c-6cf4626b161d

1 STK 230 263 319 10930 111376

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : S4R_Burgerhout_Afvoerpijp l=250

1 STK 230 263 319 10930 111441

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 5 STK 230 263 319 10930 111176

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 45 Graden 1 STK 230 263 319 10930 111203

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 4 STK 230 263 319 10930 111204

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 7 STK 230 263 319 10930 111213

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 4 STK 230 263 319 10930 111283

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Kanaalrooster standaard, 5 STK 230 263 319 10930 111284

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Adapter, 248 3 STK 230 263 319 10930 111286

Page 117: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

115

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 3 STK 230 263 319 10930 111287

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 6 STK 230 263 319 10930 111288

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 200-200

1 STK 230 263 319 10930 111289

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 2 STK 230 263 319 10930 111290

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 315-315

1 STK 230 263 319 10930 111291

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Muurrooster, 2 STK 230 263 319 10930 111293

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_9c5e0bfa-2637-46b1-86e2-f500476c25a5

2 STK 230 263 319 10930 111326

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Flex Ducts Type : S4Rx_Generic_Round 1 STK 230 263 319 10930 111328

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 1 STK 230 263 319 10930 111329

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

74

Vaste sanitaire voorzieningen

7411 Standaard, sanitaire toestellen; normaal

741100 Closetcombinatie inbouw Plumbing Fixtures

Type : 74_ISR_urinoir 1 STK 230 263 319 10930 110960

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

75

Vaste onderhoudsvoorzieningen

7510 Standaard, algemeen (verzamelniveau)

751000 Standaard, algemeen (verzamelniveau), Algemeen

Plumbing Fixtures

Type : Mop_Sink_1577 1 STK 230 263 319 10930 110966

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

83 Losse keukeninventaris

8310 Standaard, algemeen (verzamelniveau)

831000 Standaard, algemeen (verzamelniveau), Algemeen

Furniture Type : HDL_opstelplaatsen 25 STK 230 263 319 10930 110888

99 High Pressure Laboratory

INBL01

Interior Box Laboratory

90 Terrein 9000 Terreinvoorzieningen 900000 Terrein voorzieningen Planting Type : 5500_Golden Chain 1 STK 230 263 319 10930 111006

Page 118: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

116

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

Floors Type : 200_23_basisvloer_150mm 1 STK 230 263 319 10927 110862

99 High Pressure Laboratory

INCA01

Interior Common Area

Floors Type : 200_23_basisvloer_100mm 1 STK 230 263 319 10927 110866

99 High Pressure Laboratory

INCA01

Interior Common Area

Air Terminals

Type : N/A, 1 STK 230 263 319 10927 111166

99 High Pressure Laboratory

INCA01

Interior Common Area

Duct Accessories

Type : Filter_592x592x534 4 STK 230 263 319 10927 111227

99 High Pressure Laboratory

INCA01

Interior Common Area

Duct Accessories

Type : Filter_287x592x534 2 STK 230 263 319 10927 111228

99 High Pressure Laboratory

INCA01

Interior Common Area

Duct Accessories

Type : Atex Filter_292x592x535 LBK2 2 STK 230 263 319 10927 111229

99 High Pressure Laboratory

INCA01

Interior Common Area

Duct Accessories

Type : Atex Filter_490x592x535 LBK2 1 STK 230 263 319 10927 111230

99 High Pressure Laboratory

INCA01

Interior Common Area

Air Terminals

Type : PRIMO Model 550 1 STK 230 263 319 10927 111349

99 High Pressure Laboratory

INCA01

Interior Common Area

Air Terminals

Type : Adapter, 125_a518c2a8-a608-454f-b48e-fe17e2e5d6ad

2 STK 230 263 319 10927 111381

99 High Pressure Laboratory

INCA01

Interior Common Area

Air Terminals

Type : S4R_Terminal_Wall_IN 2 STK 230 263 319 10927 111395

99 High Pressure Laboratory

INCA01

Interior Common Area

21 Buitenwanden

2110 Niet constructief, algemeen (verzamelniveau)

211000 Niet constructief, algemeen (verzamelniveau), Algemeen

Walls Type : 300_21_kantplank 2 STK 230 263 319 10927 110929

99 High Pressure Laboratory

INCA01

Interior Common Area

21 Buitenwanden

2110 Niet constructief, algemeen (verzamelniveau)

211000 Niet constructief, algemeen (verzamelniveau), Algemeen

Walls Type : 300_21_isolatie hard_60 2 STK 230 263 319 10927 110977

99 High Pressure Laboratory

INCA01

Interior Common Area

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_210 bruin 5 STK 230 263 319 10927 110835

99 High Pressure Laboratory

INCA01

Interior Common Area

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_100 bruin 3 STK 230 263 319 10927 110836

99 High Pressure Laboratory

INCA01

Interior Common Area

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_100 1 STK 230 263 319 10927 110944

99 High Pressure Laboratory

INCA01

Interior Common Area

22 Binnenwanden

2221 Constructief, massieve wanden

222141 Walls Type : 300_22_ihw beton_100 1 STK 230 263 319 10927 110860

99 High Pressure Laboratory

INCA01

Interior Common Area

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : stelcon plaat 2 STK 230 263 319 10927 111003

Page 119: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

117

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonklinkers 2 STK 230 263 319 10927 111004

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 40 STK 230 263 319 10927 110831

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_320mm 1 STK 230 263 319 10927 110837

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_100mm 20 STK 230 263 319 10927 110838

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_23_schoorsteen_bekleding 5 STK 230 263 319 10927 110839

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_32_rooster_boven_kozijn 2 STK 230 263 319 10927 110911

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-76-12 1 STK 230 263 319 10927 110942

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-90-12 iso

1 STK 230 263 319 10927 110972

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_Heraklith WBDBO60min

1 STK 230 263 319 10927 110973

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : HEA120 17 STK 230 263 319 10927 110890

99 High Pressure Laboratory

INCA01

Interior Common Area

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : 20x70 1 STK 230 263 319 10927 110915

99 High Pressure Laboratory

INCA01

Interior Common Area

31 Buitenwandopeningen

3120 Gevuld met ramen, algemeen (verzamelniveau)

312000

Gevuld met ramen, algemeen (verzamelniveau), Algemeen

Windows Type : H06 2 STK 230 263 319 10927 110885

99 High Pressure Laboratory

INCA01

Interior Common Area

31 Buitenwandopeningen

3131 Gevuld met deuren, draaideuren

313121 Doors Type : glasdeur 2 STK 230 263 319 10927 110931

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3230 Gevuld met deuren, algemeen (verzamelniveau)

323000

Gevuld met deuren, algemeen (verzamelniveau), Algemeen

Doors Type : rozet 2 STK 230 263 319 10927 110852

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323100 Gevuld met deuren, draaideuren, Draaideuren

Doors Type : merk c-865 1 STK 230 263 319 10927 110851

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323100 Gevuld met deuren, draaideuren, Draaideuren

Doors Type : merk e 1 STK 230 263 319 10927 110853

Page 120: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

118

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323100 Gevuld met deuren, draaideuren, Draaideuren

Doors Type : merk 120 1 STK 230 263 319 10927 110868

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : H03 4 STK 230 263 319 10927 110881

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : H04 2 STK 230 263 319 10927 110882

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : H05 2 STK 230 263 319 10927 110883

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : lakdeur_stomp 9 STK 230 263 319 10927 110916

99 High Pressure Laboratory

INCA01

Interior Common Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : H08 3 STK 230 263 319 10927 110943

99 High Pressure Laboratory

INCA01

Interior Common Area

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_tegelwerk 30 STK 230 263 319 10927 110875

99 High Pressure Laboratory

INCA01

Interior Common Area

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_12 2 STK 230 263 319 10927 110954

99 High Pressure Laboratory

INCA01

Interior Common Area

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_saus-oranje 1 STK 230 263 319 10927 110955

99 High Pressure Laboratory

INCA01

Interior Common Area

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_99_beton_keerband 2 STK 230 263 319 10927 111018

99 High Pressure Laboratory

INCA01

Interior Common Area

43 Vloerafwerkingen

4322 Verhoogde vloer 432231 Floors Type : 300_43_tegelvloer_300x300_20 2 STK 230 263 319 10927 110876

99 High Pressure Laboratory

INCA01

Interior Common Area

43 Vloerafwerkingen

4322 Verhoogde vloer 432236 Floors Type : 300_43_staptegels_300x300 1 STK 230 263 319 10927 110984

99 High Pressure Laboratory

INCA01

Interior Common Area

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_sauswerk_antraciet 1 STK 230 263 319 10927 110918

99 High Pressure Laboratory

INCA01

Interior Common Area

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_isolatie+Heraklith 3 STK 230 263 319 10927 110920

99 High Pressure Laboratory

INCA01

Interior Common Area

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_pir_Rc2,5 2 STK 230 263 319 10927 110930

99 High Pressure Laboratory

INCA01

Interior Common Area

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_akoestisch_1200x1200 2 STK 230 263 319 10927 110932

99 High Pressure Laboratory

INCA01

Interior Common Area

47 Dakafwerkingen

4721 Bekledingen, vlakke dak bekledingen

472100 Bekledingen, vlakke dak bekledingen, Algemeen

Floors Type : 300_23_isolatie_100mm kouddak

1 STK 230 263 319 10927 110928

Page 121: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

119

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

54 Gassen 5411 Brandstof, aardgasvoorziening

541100 Brandstof, aardgasvoorziening, Algemeen

Pipes Type : Steel pipe Fe-35 124 STK 230 263 319 10927 111054

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-100 2 STK 230 263 319 10927 111097

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 12 STK 230 263 319 10927 111098

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 6 STK 230 263 319 10927 111120

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 5 STK 230 263 319 10927 111134

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 100-100

3 STK 230 263 319 10927 111164

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Kanaalrooster deflector, 4 STK 230 263 319 10927 111316

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=1000, 315-315

1 STK 230 263 319 10927 111320

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 7 STK 230 263 319 10927 111321

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 4 STK 230 263 319 10927 111331

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : N/A, 100 1 STK 230 263 319 10927 111359

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA050, L=1000, 250-250_833693a7-a50e-4325-b431-c64ea1d76390

1 STK 230 263 319 10927 111397

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, MSA 100, L=500, 600x600-600x600_e62c6a59-e7a3-416e-8807-3ef279c3baef

1 STK 230 263 319 10927 111410

Page 122: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

120

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 2 STK 230 263 319 10927 111411

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 3 STK 230 263 319 10927 111413

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 100-100

1 STK 230 263 319 10927 111422

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 Graden 1 STK 230 263 319 10927 111428

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_Burgerhout_Afvoerpijp l=250

1 STK 230 263 319 10927 111436

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 4 STK 230 263 319 10927 111067

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-125 2 STK 230 263 319 10927 111070

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-100 5 STK 230 263 319 10927 111071

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 39 STK 230 263 319 10927 111072

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 33 STK 230 263 319 10927 111073

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 31 STK 230 263 319 10927 111074

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 4 STK 230 263 319 10927 111085

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 19 STK 230 263 319 10927 111087

Page 123: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

121

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-160 1 STK 230 263 319 10927 111119

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 26 STK 230 263 319 10927 111128

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK 230 263 319 10927 111169

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Round 1 STK 230 263 319 10927 111178

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 3 STK 230 263 319 10927 111186

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK 230 263 319 10927 111194

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315

3 STK 230 263 319 10927 111265

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

4 STK 230 263 319 10927 111266

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 250-250

1 STK 230 263 319 10927 111268

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

3 STK 230 263 319 10927 111270

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 200-200_61a15fa6-babd-4bc3-975c-cf43baf875fc

2 STK 230 263 319 10927 111274

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-EU, 355-355

2 STK 230 263 319 10927 111310

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, MSA 100, L=1000, 800x900-800x900_225060a9-1187-4e77-adb8-f0a87ccf79ea

1 STK 230 263 319 10927 111317

Page 124: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

122

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : LUKA, 90°, 900x900-800x900_969b0726-70d7-4bdb-8798-796d66ca733e

1 STK 230 263 319 10927 111318

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 1 STK 230 263 319 10927 111346

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR

1 STK 230 263 319 10927 111358

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : N/A, 100 1 STK 230 263 319 10927 111360

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 80-80

1 STK 230 263 319 10927 111361

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 125-125

1 STK 230 263 319 10927 111394

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR Compact

2 STK 230 263 319 10927 111409

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Rechte kanalen 7 STK 230 263 319 10927 111129

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : standaard 1 STK 230 263 319 10927 111130

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Muurrooster, 1 STK 230 263 319 10927 111165

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250

1 STK 230 263 319 10927 111179

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 1 D 1 STK 230 263 319 10927 111187

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Insulations

Type : Isolatie mineralewol 100mm 2 STK 230 263 319 10927 111219

Page 125: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

123

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - T-stuk 3 STK 230 263 319 10927 111298

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Kanaalrooster standaard, 5 STK 230 263 319 10927 111299

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : magicirc_plug_001 2 STK 230 263 319 10927 111300

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Standaard, 315 2 STK 230 263 319 10927 111306

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Adapter, 250 1 STK 230 263 319 10927 111307

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK 230 263 319 10927 111309

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Plenumbox, 398-398-398-398 2 STK 230 263 319 10927 111315

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - Zadelstuk 1 STK 230 263 319 10927 111335

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 7 STK 230 263 319 10927 111066

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 23 STK 230 263 319 10927 111076

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 11 STK 230 263 319 10927 111125

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 11 STK 230 263 319 10927 111126

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 10 STK 230 263 319 10927 111127

Page 126: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

124

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_LUKA_Verzinkt 3m 3 STK 230 263 319 10927 111161

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 16 STK 230 263 319 10927 111185

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Saddle_Rectangular 1 STK 230 263 319 10927 111191

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 1 STK 230 263 319 10927 111192

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Connection_Rectangular_AI_Generic

1 STK 230 263 319 10927 111217

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

2 STK 230 263 319 10927 111269

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 3 STK 230 263 319 10927 111271

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : Bergschenhoek, Verbinding hulpstuk, 250-250_83af97c1-56f1-4dd9-8c83-a9dcdb78a9bb

3 STK 230 263 319 10927 111276

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_9c5e0bfa-2637-46b1-86e2-f500476c25a5

2 STK 230 263 319 10927 111277

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, MSA 200, L=500, 1600x800-1600x800_97464c76-7b4a-4678-8cca-7c59f1454f9d

1 STK 230 263 319 10927 111319

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250

2 STK 230 263 319 10927 111378

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 315-315

3 STK 230 263 319 10927 111389

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Plenumbox, 315-315-315-315 2 STK 230 263 319 10927 111390

Page 127: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

125

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Flex Ducts Type : S4Rx_Generic_Round 2 STK 230 263 319 10927 111391

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Round 3 STK 230 263 319 10927 111400

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Reducer_Round_AI_Generic

1 STK 230 263 319 10927 111401

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK 230 263 319 10927 111402

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Standaard, 200 1 STK 230 263 319 10927 111403

99 High Pressure Laboratory

INCA01

Interior Common Area

57 Luchtbehandeling

5760 Lokaal, algemeen (verzamelniveau)

576000 Lokaal, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 1 STK 230 263 319 10927 111135

99 High Pressure Laboratory

INCA01

Interior Common Area

73 Vaste keukenvoorzieningen

7311 Standaard, keukenmeubilering

731100 Keukenblok algemeen Furniture Systems

Type : met koken 1 STK 230 263 319 10927 110926

99 High Pressure Laboratory

INCA01

Interior Common Area

74

Vaste sanitaire voorzieningen

7411 Standaard, sanitaire toestellen; normaal

741100 Closetcombinatie inbouw Plumbing Fixtures

Type : 63_ISR_inbouwreservoir_toilet 1 STK 230 263 319 10927 110877

99 High Pressure Laboratory

INCA01

Interior Common Area

74

Vaste sanitaire voorzieningen

7411 Standaard, sanitaire toestellen; normaal

741100 Closetcombinatie inbouw Plumbing Fixtures

Type : 450 (d) x 500 (b) 2 STK 230 263 319 10927 110878

99 High Pressure Laboratory

INCA01

Interior Common Area

74

Vaste sanitaire voorzieningen

7411 Standaard, sanitaire toestellen; normaal

741100 Closetcombinatie inbouw Generic Models

Type : douche 980 x 980 1 STK 230 263 319 10927 110879

99 High Pressure Laboratory

INCA01

Interior Common Area

74

Vaste sanitaire voorzieningen

7411 Standaard, sanitaire toestellen; normaal

741100 Closetcombinatie inbouw Plumbing Fixtures

Type : Duschsitz 1 STK 230 263 319 10927 110880

99 High Pressure Laboratory

INCA01

Interior Common Area

83 Losse keukeninventaris

8310 Standaard, algemeen (verzamelniveau)

831000 Standaard, algemeen (verzamelniveau), Algemeen

Furniture Type : HDL_opstelplaatsen 11 STK 230 263 319 10927 110884

99 High Pressure Laboratory

ING01

Interior General

Floors Type : 200_23_basisvloer_300mm 3 STK 230 263 319 10932 110865

99 High Pressure Laboratory

ING01

Interior General

Walls Type : 200_20_basis_100 1 STK 230 263 319 10932 110913

Page 128: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

126

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

ING01

Interior General

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Structural Beam Systems

Type : 300_28_balklaag 1 STK 230 263 319 10932 110981

99 High Pressure Laboratory

ING01

Interior General

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 1 STK 230 263 319 10932 111027

99 High Pressure Laboratory

ING01

Interior General

31 Buitenwandopeningen

3111 Niet gevuld, deglichtopeningen

311100 Niet gevuld, deglichtopeningen, Daglichtopeningen

Generic Models

Type : glas 2 2 STK 230 263 319 10932 110936

99 High Pressure Laboratory

ING01

Interior General

31 Buitenwandopeningen

3130 Gevuld met deuren, algemeen (verzamelniveau)

313000

Gevuld met deuren, algemeen (verzamelniveau), Algemeen

Doors Type : redeca 1 STK 230 263 319 10932 110937

99 High Pressure Laboratory

ING01

Interior General

31 Buitenwandopeningen

3131 Gevuld met deuren, draaideuren

313100 Gevuld met deuren, draaideuren, Draaideuren

Curtain Panels

Type : deur 1 STK 230 263 319 10932 110935

99 High Pressure Laboratory

ING01

Interior General

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : dubbele deur met glas 1 STK 230 263 319 10932 110990

99 High Pressure Laboratory

ING01

Interior General

43 Vloerafwerkingen

4300 Vloerafwerkingen 430000 Vloerafwerking, algemeen Floors Type : 200_43_afwerkvloer_60 3 STK 230 263 319 10932 110905

99 High Pressure Laboratory

ING01

Interior General

45 Plafondafwerkingen

4500 Plafondafwerkingen algemeen

450000 Plafondafwerkingen, algemeen

Ceilings Type : 300_44_gipsvinyl_600x600 3 STK 230 263 319 10932 110978

99 High Pressure Laboratory

ING01

Interior General

45 Plafondafwerkingen

4500 Plafondafwerkingen algemeen

450000 Plafondafwerkingen, algemeen

Ceilings Type : 300_44_Rockfon Krios_600x600

1 STK 230 263 319 10932 111025

99 High Pressure Laboratory

ING01

Interior General

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_sauswerk_antraciet 1 STK 230 263 319 10932 111026

99 High Pressure Laboratory

INMA01

Interior Mounting Area

Air Terminals

Type : N/A, 3 STK 230 263 319 10926 111167

99 High Pressure Laboratory

INMA01

Interior Mounting Area

Duct Fittings

Type : LUKA, Recht zadel 90° 800, 2030x450-2030x450_e90e9e1b-1fbc-46d3-a176-da34db898d26

1 STK 230 263 319 10926 111214

99 High Pressure Laboratory

INMA01

Interior Mounting Area

Air Terminals

Type : Standaard, 4 STK 230 263 319 10926 111398

99 High Pressure Laboratory

INMA01

Interior Mounting Area

Air Terminals

Type : Overdruk Jalouziklep 1 STK 230 263 319 10926 111423

99 High Pressure Laboratory

INMA01

Interior Mounting Area

21 Buitenwanden

2111 Niet constructief, massieve wanden

211111 Walls Type : 300_21_metselwerk_100 1 STK 230 263 319 10926 110983

99 High Pressure Laboratory

INMA01

Interior Mounting Area

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : stelcon plaat 1 STK 230 263 319 10926 111019

Page 129: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

127

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INMA01

Interior Mounting Area

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : grind 1 STK 230 263 319 10926 111022

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 9 STK 230 263 319 10926 110830

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_320mm 1 STK 230 263 319 10926 110834

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_100mm 9 STK 230 263 319 10926 110849

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_32_rooster_boven_kozijn 5 STK 230 263 319 10926 110850

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281111 Structural Framing

Type : 71x246 11 STK 230 263 319 10926 110982

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : HEA120 6 STK 230 263 319 10926 110892

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : IPE160 1 STK 230 263 319 10926 110979

99 High Pressure Laboratory

INMA01

Interior Mounting Area

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA140 2 STK 230 263 319 10926 110980

99 High Pressure Laboratory

INMA01

Interior Mounting Area

31 Buitenwandopeningen

3131 Gevuld met deuren, draaideuren

313100 Gevuld met deuren, draaideuren, Draaideuren

Curtain Panels

Type : deur 2 STK 230 263 319 10926 110874

99 High Pressure Laboratory

INMA01

Interior Mounting Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323100 Gevuld met deuren, draaideuren, Draaideuren

Doors Type : H09 1 STK 230 263 319 10926 110956

99 High Pressure Laboratory

INMA01

Interior Mounting Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : H02 4 STK 230 263 319 10926 110873

99 High Pressure Laboratory

INMA01

Interior Mounting Area

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : H07 2 STK 230 263 319 10926 110941

99 High Pressure Laboratory

INMA01

Interior Mounting Area

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_99_beton_keerband 2 STK 230 263 319 10926 111021

99 High Pressure Laboratory

INMA01

Interior Mounting Area

43 Vloerafwerkingen

4322 Verhoogde vloer 432236 Floors Type : 300_43_staptegels_300x300 1 STK 230 263 319 10926 111023

99 High Pressure Laboratory

INMA01

Interior Mounting Area

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_sauswerk_antraciet 3 STK 230 263 319 10926 110919

99 High Pressure Laboratory

INMA01

Interior Mounting Area

54 Gassen 5411 Brandstof, aardgasvoorziening

541100 Brandstof, aardgasvoorziening, Algemeen

Pipes Type : Steel pipe Fe-35 134 STK 230 263 319 10926 111055

Page 130: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

128

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 7 STK 230 263 319 10926 111075

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-160 1 STK 230 263 319 10926 111079

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 1 STK 230 263 319 10926 111080

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 2 STK 230 263 319 10926 111082

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 7 STK 230 263 319 10926 111083

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 2 STK 230 263 319 10926 111267

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 1 STK 230 263 319 10926 111412

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_Burgerhout_Afvoerpijp l=250

1 STK 230 263 319 10926 111427

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-160 5 STK 230 263 319 10926 111078

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-125 4 STK 230 263 319 10926 111084

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 43 STK 230 263 319 10926 111088

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 20 STK 230 263 319 10926 111089

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 18 STK 230 263 319 10926 111090

Page 131: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

129

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 7 STK 230 263 319 10926 111091

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 2 STK 230 263 319 10926 111092

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : KSO 200 1 STK 230 263 319 10926 111093

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_Bergschenhoek_Spiro zaaglengte

3 STK 230 263 319 10926 111154

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK 230 263 319 10926 111155

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : N/A, 100 2 STK 230 263 319 10926 111156

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Flex Ducts Type : S4Rx_Generic_Round 3 STK 230 263 319 10926 111157

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_LUKA_Verzinkt 3m 1 STK 230 263 319 10926 111158

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 160-160

5 STK 230 263 319 10926 111159

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 125-125

4 STK 230 263 319 10926 111160

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 19 STK 230 263 319 10926 111170

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 6 STK 230 263 319 10926 111173

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 1 STK 230 263 319 10926 111220

Page 132: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

130

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 1 STK 230 263 319 10926 111221

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : LUKA, 90°, 520x600-800x600_44a9a3aa-7a68-45c3-b438-278707bacb89

1 STK 230 263 319 10926 111222

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 1 STK 230 263 319 10926 111223

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315

2 STK 230 263 319 10926 111263

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

1 STK 230 263 319 10926 111264

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 1 D 2 STK 230 263 319 10926 111171

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Adapter, 250 2 STK 230 263 319 10926 111313

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - T-stuk 7 STK 230 263 319 10926 111314

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : standaard 1 STK 230 263 319 10926 111353

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 30 gr 5 STK 230 263 319 10926 111377

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 7 STK 230 263 319 10926 111077

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 13 STK 230 263 319 10926 111081

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 7 STK 230 263 319 10926 111094

Page 133: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

131

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 10 STK 230 263 319 10926 111121

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 15 STK 230 263 319 10926 111122

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 1 STK 230 263 319 10926 111190

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 4 STK 230 263 319 10926 111193

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_4d0dda9b-4f74-47d6-9de4-41f39c10c1fb

1 STK 230 263 319 10926 111273

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 200-200

1 STK 230 263 319 10926 111379

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 2 STK 230 263 319 10926 111380

99 High Pressure Laboratory

INMA01

Interior Mounting Area

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Standaard, 200 1 STK 230 263 319 10926 111399

99 High Pressure Laboratory

INMA01

Interior Mounting Area

83 Losse keukeninventaris

8310 Standaard, algemeen (verzamelniveau)

831000 Standaard, algemeen (verzamelniveau), Algemeen

Furniture Type : HDL_opstelplaatsen 43 STK 230 263 319 10926 110871

99 High Pressure Laboratory

INMA01

Interior Mounting Area

83 Losse keukeninventaris

8310 Standaard, algemeen (verzamelniveau)

831000 Standaard, algemeen (verzamelniveau), Algemeen

Generic Models

Type : opstelplaats wasbak 1 STK 230 263 319 10926 110872

99 High Pressure Laboratory

INPH01

Interior Process Hall

Floors Type : 200_23_basisvloer_200mm 1 STK 230 263 319 10928 110854

99 High Pressure Laboratory

INPH01

Interior Process Hall

Structural Framing

Type : Bout M20x250 8.8 DIN931 7 STK 230 263 319 10928 110963

99 High Pressure Laboratory

INPH01

Interior Process Hall

Structural Framing

Type : Tapbout M12x120 8.8 DIN933 2 STK 230 263 319 10928 110964

99 High Pressure Laboratory

INPH01

Interior Process Hall

Structural Framing

Type : Tapbout M12x120 8.8 DIN933 40

1 STK 230 263 319 10928 110965

Page 134: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

132

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

Duct Accessories

Type : Atex Filter_292x592x535 LBK2 1 STK 230 263 319 10928 111231

99 High Pressure Laboratory

INPH01

Interior Process Hall

Duct Accessories

Type : Filter_592x592x534 2 STK 230 263 319 10928 111232

99 High Pressure Laboratory

INPH01

Interior Process Hall

Duct Accessories

Type : Filter_287x592x534 3 STK 230 263 319 10928 111233

99 High Pressure Laboratory

INPH01

Interior Process Hall

Duct Accessories

Type : Filter_592x287x534 1 STK 230 263 319 10928 111234

99 High Pressure Laboratory

INPH01

Interior Process Hall

Pipe Fittings

Type : S4R - Keaser, Keaser-SM-12T__2dcecc4424fe_42f5_5bee_7d352dcecc44

1 STK 230 263 319 10928 111367

99 High Pressure Laboratory

INPH01

Interior Process Hall

Air Terminals

Type : N/A, 200 1 STK 230 263 319 10928 111382

99 High Pressure Laboratory

INPH01

Interior Process Hall

Air Terminals

Type : S4R_Terminal_Wall_IN 2 STK 230 263 319 10928 111383

99 High Pressure Laboratory

INPH01

Interior Process Hall

21 Buitenwanden

2110 Niet constructief, algemeen (verzamelniveau)

211000 Niet constructief, algemeen (verzamelniveau), Algemeen

Walls Type : 300_21_isolatie_90 2 STK 230 263 319 10928 110903

99 High Pressure Laboratory

INPH01

Interior Process Hall

21 Buitenwanden

2110 Niet constructief, algemeen (verzamelniveau)

211000 Niet constructief, algemeen (verzamelniveau), Algemeen

Walls Type : 300_21_kantplank 3 STK 230 263 319 10928 110912

99 High Pressure Laboratory

INPH01

Interior Process Hall

21 Buitenwanden

2123 Constructief, systeemwanden

212318 Walls Type : 300_21_HSB_38x38 8 STK 230 263 319 10928 110988

99 High Pressure Laboratory

INPH01

Interior Process Hall

22 Binnenwanden

2213 Niet constructief, systeemwanden; vast

221300 Systeemwanden, metaal binnen

Walls Type : 300_22_tussenwand_inloopbox 10 STK 230 263 319 10928 110974

99 High Pressure Laboratory

INPH01

Interior Process Hall

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : grind 1 STK 230 263 319 10928 111020

99 High Pressure Laboratory

INPH01

Interior Process Hall

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 8 STK 230 263 319 10928 110832

99 High Pressure Laboratory

INPH01

Interior Process Hall

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_21_HSB_wand 12-90-12 iso

8 STK 230 263 319 10928 110899

99 High Pressure Laboratory

INPH01

Interior Process Hall

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : 20x70 20 STK 230 263 319 10928 110961

99 High Pressure Laboratory

INPH01

Interior Process Hall

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Framing

Type : HEA140 1 STK 230 263 319 10928 110993

99 High Pressure Laboratory

INPH01

Interior Process Hall

31 Buitenwandopeningen

3111 Niet gevuld, deglichtopeningen

311100 Niet gevuld, deglichtopeningen, Daglichtopeningen

Generic Models

Type : glas 2 6 STK 230 263 319 10928 110896

Page 135: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

133

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

31 Buitenwandopeningen

3111 Niet gevuld, deglichtopeningen

311100 Niet gevuld, deglichtopeningen, Daglichtopeningen

Windows Type : glas 2 2 STK 230 263 319 10928 111049

99 High Pressure Laboratory

INPH01

Interior Process Hall

31 Buitenwandopeningen

3130 Gevuld met deuren, algemeen (verzamelniveau)

313000

Gevuld met deuren, algemeen (verzamelniveau), Algemeen

Doors Type : redeca 1 STK 230 263 319 10928 110904

99 High Pressure Laboratory

INPH01

Interior Process Hall

31 Buitenwandopeningen

3131 Gevuld met deuren, draaideuren

313100 Gevuld met deuren, draaideuren, Draaideuren

Curtain Panels

Type : deur 1 STK 230 263 319 10928 110889

99 High Pressure Laboratory

INPH01

Interior Process Hall

31 Buitenwandopeningen

3131 Gevuld met deuren, draaideuren

313121 Doors Type : glasdeur 2 STK 230 263 319 10928 110886

99 High Pressure Laboratory

INPH01

Interior Process Hall

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323100 Gevuld met deuren, draaideuren, Draaideuren

Doors Type : H09 1 STK 230 263 319 10928 110957

99 High Pressure Laboratory

INPH01

Interior Process Hall

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : deur met glas antraciet 12 STK 230 263 319 10928 110986

99 High Pressure Laboratory

INPH01

Interior Process Hall

32 Binnenwandopeningen

3231 Gevuld met deuren, draaideuren

323121 Doors Type : dubbele deur met glas 3 STK 230 263 319 10928 110987

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4110 Buitenwandafwerkingen

411000 Buitenwandafwerkingen, Algemeen

Generic Models

Type : std 1v 2 STK 230 263 319 10928 110906

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_6 4 STK 230 263 319 10928 110975

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_12 2 STK 230 263 319 10928 110976

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_99_beton_keerband 6 STK 230 263 319 10928 111016

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411251 Ceilings Type : 300_45_glasvezel_beton 1 STK 230 263 319 10928 110902

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4113 Buitenwandafwerkingen, voorzetwanden

411300 Buitenwandafwerkingen, voorzetwanden, Algemeen

Walls Type : 300_21_HSB wand proceshal 2 STK 230 263 319 10928 110938

99 High Pressure Laboratory

INPH01

Interior Process Hall

41 Buitenwandafwerkingen

4113 Buitenwandafwerkingen, voorzetwanden

411300 Buitenwandafwerkingen, voorzetwanden, Algemeen

Walls Type : 300_21_HSB wand proceshal kop

1 STK 230 263 319 10928 110953

99 High Pressure Laboratory

INPH01

Interior Process Hall

43 Vloerafwerkingen

4321 Niet verhoogd, afwerklagen

432100 Niet verhoogd, afwerklagen, Algemeen

Floors Type : 300_43_vloercoating_oranje 1 STK 230 263 319 10928 110959

99 High Pressure Laboratory

INPH01

Interior Process Hall

43 Vloerafwerkingen

4321 Niet verhoogd, afwerklagen

432111 Sportvloer, hout waslaag Floors Type : 300_43_cementdekvloer_30 1 STK 230 263 319 10928 110901

Page 136: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

134

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

43 Vloerafwerkingen

4322 Verhoogde vloer 432236 Floors Type : 300_43_staptegels_300x300 2 STK 230 263 319 10928 110933

99 High Pressure Laboratory

INPH01

Interior Process Hall

45 Plafondafwerkingen

4500 Plafondafwerkingen algemeen

450000 Plafondafwerkingen, algemeen

Ceilings Type : 300_44_gipsvinyl_600x600 1 STK 230 263 319 10928 110989

99 High Pressure Laboratory

INPH01

Interior Process Hall

45 Plafondafwerkingen

4510 Verlaagd, algemeen 451000 Verlaagd, algemeen, Algemeen

Ceilings Type : 300_44_sauswerk_antraciet 1 STK 230 263 319 10928 110922

99 High Pressure Laboratory

INPH01

Interior Process Hall

47 Dakafwerkingen

4721 Bekledingen, vlakke dak bekledingen

472100 Bekledingen, vlakke dak bekledingen, Algemeen

Floors Type : 300_23_isolatie_150mm afschot

1 STK 230 263 319 10928 110900

99 High Pressure Laboratory

INPH01

Interior Process Hall

54 Gassen 5411 Brandstof, aardgasvoorziening

541100 Brandstof, aardgasvoorziening, Algemeen

Pipes Type : Steel pipe Fe-35 542 STK 230 263 319 10928 111053

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-100 3 STK 230 263 319 10928 111096

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 20 STK 230 263 319 10928 111099

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 100-100

3 STK 230 263 319 10928 111163

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 1 STK 230 263 319 10928 111205

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 1 STK 230 263 319 10928 111206

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 8 STK 230 263 319 10928 111207

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 8 STK 230 263 319 10928 111258

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 6 STK 230 263 319 10928 111330

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 125-125

3 STK 230 263 319 10928 111332

Page 137: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

135

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 3 STK 230 263 319 10928 111333

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 2 STK 230 263 319 10928 111347

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 250-250

5 STK 230 263 319 10928 111366

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Brandklep FKRS-EU, 250-250

1 STK 230 263 319 10928 111396

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : S4R_Burgerhout_Afvoerpijp l=250

3 STK 230 263 319 10928 111432

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R_Bend_Round_AI_Generic 1 STK 230 263 319 10928 111433

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 Graden 1 STK 230 263 319 10928 111434

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5720 Lokale mechanische afzuiging, algemeen (verzamelniveau)

572000

Lokale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 400-400

1 STK 230 263 319 10928 111435

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-250 3 STK 230 263 319 10928 111086

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : circ-grille-315 11 STK 230 263 319 10928 111104

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : URH/A-160 6 STK 230 263 319 10928 111105

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 48 STK 230 263 319 10928 111106

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 42 STK 230 263 319 10928 111107

Page 138: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

136

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 25 STK 230 263 319 10928 111108

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 22 STK 230 263 319 10928 111131

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 33 STK 230 263 319 10928 111132

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Ducts Type : Wandgoot 1 STK 230 263 319 10928 111174

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : magirect_plug1_001 2 STK 230 263 319 10928 111175

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 160-160

5 STK 230 263 319 10928 111197

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - LUKA, Regelklep, 315-315

11 STK 230 263 319 10928 111198

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 2 STK 230 263 319 10928 111251

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 11 STK 230 263 319 10928 111252

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK electrische servomotor, 315-315

5 STK 230 263 319 10928 111260

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, RECT, 300x200-300x200 TVJ

1 STK 230 263 319 10928 111279

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : N/A, 100 1 STK 230 263 319 10928 111350

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR Compact

4 STK 230 263 319 10928 111354

Page 139: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

137

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 7 STK 230 263 319 10928 111355

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : LUKA, Recht zadel 90°, 1000x500-1000x500

1 STK 230 263 319 10928 111368

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 200-200

2 STK 230 263 319 10928 111384

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 160-160

1 STK 230 263 319 10928 111392

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 125-125

1 STK 230 263 319 10928 111393

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5730

Centrale mechanische afzuiging, algemeen (verzamelniveau)

573000

Centrale mechanische afzuiging, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, TVR Compact, 250-250 TVR Compact1

1 STK 230 263 319 10928 111408

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - T-stuk 16 STK 230 263 319 10928 111199

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Insulations

Type : Isolatie mineralewol 100mm 5 STK 230 263 319 10928 111201

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Rechte kanalen 8 STK 230 263 319 10928 111256

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : standaard 6 STK 230 263 319 10928 111257

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : 1 D 2 STK 230 263 319 10928 111259

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Duct Fittings

Type : magicirc_plug_001 2 STK 230 263 319 10928 111301

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Kanaalrooster standaard, 4 STK 230 263 319 10928 111304

Page 140: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

138

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Standaard, 315 3 STK 230 263 319 10928 111305

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Air Terminals

Type : Adapter, 250 1 STK 230 263 319 10928 111308

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5740 Lokale mechanische ventilatie, algemeen (verzamelniveau)

574000

Lokale mechanische ventilatie, algemeen (verzamelniveau), Algemeen, roosters

Ducts Type : Ronde kanalen - Zadelstuk 1 STK 230 263 319 10928 111364

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Rechte kanalen 12 STK 230 263 319 10928 111095

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : standaard 12 STK 230 263 319 10928 111100

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - T-stuk 13 STK 230 263 319 10928 111101

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : S4Rx_Generic_Rectangular 1 STK 230 263 319 10928 111152

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Insulations

Type : Isolatie mineralewol 100mm 11 STK 230 263 319 10928 111153

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Brandklep FKR-EU, 355-355

1 STK 230 263 319 10928 111162

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 1 D 8 STK 230 263 319 10928 111172

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : S4R - LUKA, 90° scherp, 1220x800-750x800

2 STK 230 263 319 10928 111253

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 45 Graden 1 STK 230 263 319 10928 111254

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : With Flange 1 STK 230 263 319 10928 111255

Page 141: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

139

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Fittings

Type : 30 gr 9 STK 230 263 319 10928 111272

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, CA100, L=500, 250-250_9c5e0bfa-2637-46b1-86e2-f500476c25a5

1 STK 230 263 319 10928 111275

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Ducts Type : Ronde kanalen - Zadelstuk 4 STK 230 263 319 10928 111278

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Constantvolumeklep RN Standaard, 200-200

2 STK 230 263 319 10928 111280

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Adapter, 248 2 STK 230 263 319 10928 111281

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Kanaalrooster standaard, 2 STK 230 263 319 10928 111282

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, TVR Compact, 200-200 TVR

2 STK 230 263 319 10928 111357

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 160-160

2 STK 230 263 319 10928 111385

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Duct Accessories

Type : S4R - Trox Air, Afsluitkleppen AK, 315-315

1 STK 230 263 319 10928 111386

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Air Terminals

Type : Plenumbox, 315-315-315-315 2 STK 230 263 319 10928 111387

99 High Pressure Laboratory

INPH01

Interior Process Hall

57 Luchtbehandeling

5750

Centrale mechanische ventilatie, algemeen (verzamelniveau)

575000

Centrale mechanische ventilatie, algemeen (verzamelniveau), Algemeen

Flex Ducts Type : S4Rx_Generic_Round 2 STK 230 263 319 10928 111388

99 High Pressure Laboratory

INPH01

Interior Process Hall

83 Losse keukeninventaris

8310 Standaard, algemeen (verzamelniveau)

831000 Standaard, algemeen (verzamelniveau), Algemeen

Furniture Type : HDL_opstelplaatsen 7 STK 230 263 319 10928 110887

99 High Pressure Laboratory

SISB01

Side Building

Floors Type : 200_23_basisvloer_100mm 1 STK 230 263 319 10934 111030

Page 142: Digital Facility Data Transfer Approach from BIM Model to ...essay.utwente.nl/76652/1/Seyadi, Aulia Rahman 1790242 _openbaar.… · BIM models are currently developed mainly for design

140

Ge

bo

uw

Co

de

Ge

bo

uw

Om

sc

hri

jvin

g

Ru

imte

Co

de

Ru

imte

Om

sc

hri

jvin

g

Ho

ofd

ele

me

nt

Co

de

Ho

ofd

ele

me

nt

Om

sc

hri

jvin

g

Ele

me

nt

Co

de

Ele

me

nt

Om

sc

hri

jvin

g

Su

be

lem

en

t C

od

e

Su

be

lem

en

t

Om

sc

hri

jvin

g

Co

mp

on

en

t O

ms

ch

rijv

ing

Ty

pe

Co

mp

on

en

t A

an

tal

Co

mp

on

en

t E

en

he

id

Pro

jec

t_ID

Be

he

erd

er_

ID

Ge

bo

uw

_ID

Ru

imte

_ID

Co

mp

_ID

99 High Pressure Laboratory

SISB01

Side Building

Floors Type : 200_23_basisvloer_150mm 3 STK 230 263 319 10934 111034

99 High Pressure Laboratory

SISB01

Side Building

Roofs Type : 200_multiplex met bitumen 1 STK 230 263 319 10934 111037

99 High Pressure Laboratory

SISB01

Side Building

Floors Type : 200_23_hellingbaan 2 STK 230 263 319 10934 111039

99 High Pressure Laboratory

SISB01

Side Building

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : stelcon plaat 1 STK 230 263 319 10934 111002

99 High Pressure Laboratory

SISB01

Side Building

23 Vloeren 2300 Vloeren algemeen 230000 Vloeren, algemeen Floors Type : betonklinkers 1 STK 230 263 319 10934 111029

99 High Pressure Laboratory

SISB01

Side Building

28 Hoofddraagconstructies

2800 Hoofddraagconstructie algemeen

280000 Hoofddraagconstructie algemeen

Walls Type : 300_28_betonsteen_210mm 15 STK 230 263 319 10934 111028

99 High Pressure Laboratory

SISB01

Side Building

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281121 Structural Columns

Type : K60x60x3 7 STK 230 263 319 10934 111040

99 High Pressure Laboratory

SISB01

Side Building

28 Hoofddraagconstructies

2811 Kolommen en liggers, kolom-/liggerconstructies

281141 Structural Framing

Type : 150x300 4 STK 230 263 319 10934 111035

99 High Pressure Laboratory

SISB01

Side Building

31 Buitenwandopeningen

3111 Niet gevuld, deglichtopeningen

311100 Niet gevuld, deglichtopeningen, Daglichtopeningen

Windows Type : glas 2 4 STK 230 263 319 10934 111032

99 High Pressure Laboratory

SISB01

Side Building

31 Buitenwandopeningen

3130 Gevuld met deuren, algemeen (verzamelniveau)

313000

Gevuld met deuren, algemeen (verzamelniveau), Algemeen

Doors Type : 5std 4 STK 230 263 319 10934 111031

99 High Pressure Laboratory

SISB01

Side Building

31 Buitenwandopeningen

3141 Gevuld met puien, gesloten puien

314100 Gevuld met puien, gesloten puien, Algemeen

Windows Type : 31_paneel ver 6 STK 230 263 319 10934 111033

99 High Pressure Laboratory

SISB01

Side Building

31 Buitenwandopeningen

3141 Gevuld met puien, gesloten puien

314100 Gevuld met puien, gesloten puien, Algemeen

Windows Type : paneel ver 5 STK 230 263 319 10934 111038

99 High Pressure Laboratory

SISB01

Side Building

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_12 1 STK 230 263 319 10934 111036

99 High Pressure Laboratory

SISB01

Side Building

41 Buitenwandafwerkingen

4112 Buitenwandafwerkingen, bekledingen

411200 Buitenwandafwerkingen, bekledingen, Algemeen

Walls Type : 300_41_beplating_fietsenhok 1 STK 230 263 319 10934 111041